Teleste EASI ATM IND2x2 Series Operation & User’s Manual

File Specifications

Brand: Teleste
Category: Media Converter
Model: EASI ATM IND2x2 Series (Operation & User’s Manual), prSSJ3gwcnJ8k
File Info: Adobe Acrobat PDF (DjVu)
File Size:
Pages: 28 pages

Download PDF

Download Teleste EASI ATM IND2x2 Series Manual (28 pages)

Read Online:

Read the Teleste EASI ATM IND2x2 Series Operation & User’s Manual online using the built-in PDF viewer. This document explains how to operate the device, adjust settings and perform regular maintenance.

Key Pages of Document

Commander’s “Data” page view.

The Data page is used to enable and confi gure all four supported RS data channels individually. In order to operate over ATM each data channel must have similar confi guration at both ends. The VP/VC settings for all of these channels are located on the ATM page. Data Channel frames 1…4 User selectable RS modes are RS232, RS422, RS485 half duplex and RS485 full duplex (4-wire). For correct wiring refer to attachment A. User selectable baudrates for each channel are 2400, 4800, 9600, 14400, 19200, 38400 and 57600. Alternatives for number of d ...

Commander’s “Status” page view.

The Status Page lists information messages about the Decoder’s present status. The EASITM Confi gurer divides these messages into three different categories according to severity and uses Status Flags to make them more noticeable: - Alarm messages are indicated with red fl ag. - Warning messages are indicated with yellow fl ag. - Notifi cations are indicated with green fl ag. Status Flags and the corresponding text labels appears in the Status fi eld. A short description of the event can be read in the Description fi eld. Y ...

Confi guring the unit using CATVisorTM Commander

Clicking on a specifi c unit in the Element Tree Directory, a Confi guration Display appears on the right side. The Confi guration Display includes all the programmable and monitorable controls and settings of that unit. Picture 11. The Confi guration Display. The Confi guration Display window consists of several pages; Status, Properties, ATM, Data, PID, Video, In-Band Management and SNMP. Only one page is completely visible at one time. You can activate a page simply by clicking the page’s heading. See section “IND2x2 MPEG-2 Decoder ...

Confi guring the unit using CATVisorTM Commander

Clicking on a specifi c unit in the Element Tree Directory, a Confi guration Display appears on the right side. The Confi guration Display includes all the programmable and monitorable controls and settings of that unit. Picture 11. The Confi guration Display. The Confi guration Display window consists of several pages; Status, Properties, ATM, Data, PID, Video, In-Band Management and SNMP. Only one page is completely visible at one time. You can activate a page simply by clicking the page’s heading. See section “IND2x2 MPEG-2 Decoder ...

Loopback enable checkbox

When this box is ticked all incoming ATM cells are forwarded to the next device in the network. Even those cells received by the Decoder itself are copied forward. This allows Decoder daisy-chaining and full utilisation of STM-1 capacity. TS Filter checkbox Because of the ability to loop forward the ATM stream it is possible that the cells once sent are returning back to the transmitting unit. In order to prevent those cells to start another round in the network they are discarded. This box is a reminder of the automatic cell deleting that takes place in every Decoder. ...

If a data fi eld or box has a grey background, it contains read-

only information that cannot be edited. Red, yellow and green backgrounds of data fi elds or boxes indicate alarms, warnings and notifi cations related to the settings or values in them. The new settings are saved in the non-volatile memory of the confi gured unit. In this way they will be maintained even if the power is lost temporarily. When you have fi nished editing, check that the confi gured units are not indicating any warnings or alarms. For more information about alarms and warnings, please see the “Status Page� ...

Confi guring the unit using CATVisorTM Commander

Clicking on a specifi c unit in the Element Tree Directory, a Confi guration Display appears on the right side. The Confi guration Display includes all the programmable and monitorable controls and settings of that unit. Picture 11. The Confi guration Display. The Confi guration Display window consists of several pages; Status, Properties, ATM, Data, PID, Video, In-Band Management and SNMP. Only one page is completely visible at one time. You can activate a page simply by clicking the page’s heading. See section “IND2x2 MPEG-2 Decoder ...

Commander’s “ATM” page view.

The ATM page displays ATM/SDH (Asychronous Transfer Mode / Synchronous Digital Hierarchy) connection status and allows you to set all necessary VPI’s and VCI’s. VPI is the Virtual Path Identifi er. VCI is the Virtual Channel Identifi er. VPI is selectable between 1…255 and VCI between 1…65500. These values compose a pair and it is not allowed to have two similar identifi er pairs for different streams in one network. Transport stream frame In this frame you can set the received video & audio signals. Transport stream is the MPE ...

Teleste EASI ATM IND2x2 Series user guide recommended for: HDA-912, MCC101, EASI, LumiNode 1, MCC201.

⚠️ Download Safety

The Media Converter Operation & user’s manual (28 pages) is completely safe to download (last scan date: 06/03/2026).

Related PDF Instructions for Teleste EASI ATM IND2x2 Series:

Media Converter Equipment: Frequently Requested

Have some Questions about Teleste EASI ATM IND2x2 Series Device?

Get valuable and actionable advices from other Teleste EASI ATM IND2x2 Series device users. Describe your problem or question, regarding the using of EASI ATM IND2x2 Series, in as much detail as possible, and other users will be able to answer you.