THOMSON LDK 5481 Operation & User’s Manual

Specifications

Brand: THOMSON
Category: Camcorder
Model: LDK 5481 (Operation & User’s Manual)
File Type: PDF
File Size: —
Pages: 44

Read Online

Read the THOMSON LDK 5481 Operation & User’s Manual online using the built-in PDF viewer.

Text of the manual

LDK 5481 + LDK 4700 User’s Guide

ii Declaration of Conformity We, Grass Valley Nederland B.V., Kapittelweg 10, 4827 HG Breda, The Netherlands, declare under our sole responsibility that this product is in compliance with the following standards: - EN60950-1 : Safety - EN55103-1: EMC (Emission) - EN55103-2: EMC (Immunity) following the provisions of: a. the Safety Directives 73/23//EEC and 93/68/EEC b. the EMC Directives 89/336/EEC and 93/68/EEC FCC Class A Statement This product generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause interference to radio communications. It has been tested and found to comply with the limits for a class A digital device pursuant to part 15 of the FCC rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this product in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be required to correct the interference. Copyright Copyright Grass Valley Nederland B.V. 2007. Copying of this document and giving it to others, and the use or communication of the contents thereof, are forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved in the event of the grant of a patent or the registration of a utility model or design. Liable to technical alterations in the course of further development. Trademarks Grass Valley and Infinity are trademarks of Grass Valley, Inc. All other tradenames referenced are service marks, trademarks, or registered trademarks of their respective companies. Website Visit the Grass Valley public website to download the latest user’s guide updates and additional information about your broadcast product: www.thomsongrassvalley.com

LDK 5481 + LDK 4700 User’s Guide

i Table of contents Chapter 1 – DigiLink system 1.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1.2 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1.3 Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 1.4 Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 1.4.1 Digilink system SDI coax configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 1.4.2 DigiLink system multicore configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 1.4.3 Stand alone SDI coax configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 1.4.4 Stand alone multicore configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 1.5 Intercom . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 Chapter 2 – LDK 5481 DigiLink Adapter 2.1 Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4 2.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4 2.3 Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5 2.4 Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5 2.4.1 Powering the camera. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5 2.5 Attaching the LDK 5481 adapter to a camera head. . . . . . . . . . . . . . . . . . . . . . . . . 2-6 2.6 Mounting a script board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7 2.7 Adapter connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8 2.7.1 SDI video output connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8 2.7.2 SDI video input connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9 2.7.3 Multicore connector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9 2.7.4 Video signal (VF) output connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10 2.7.5 Video signal (CVBS) output connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10 2.7.6 Intercom headset connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10 2.7.7 LCP / Fibre power connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11 2.7.8 DC power output socket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11 2.7.9 DC power input socket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12 2.7.10 Script light power supply socket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12 2.8 Install menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-13 Chapter 3 – LDK 4700 base unit 3.1 Installation information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 3.1.1 Ventilation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 3.1.2 Rack mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 3.1.3 Installation notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5 3.1.4 Mains power supply chord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5 3.2 Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7 3.3 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8 3.4 Controls and indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9 3.4.1 Powering the base unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9 3.4.2 Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9 3.4.3 Set-up items . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9

LDK 5481 + LDK 4700 User’s Guide

ii 3.5 Connecting the studio signalling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11 3.5.1 Call and On-air signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11 3.6 DigiLink base unit connectors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13 3.6.1 Setup switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13 3.6.2 Audio out connector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-14 3.6.3 Signalling / Intercom / Auxiliary connector. . . . . . . . . . . . . . . . . . . . . . . . . . . 3-14 3.6.4 External video input connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-14 3.6.5 Reference input connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-14 3.6.6 Teleprompter input connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-15 3.6.7 Y, Pr, Pb output connectors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-15 3.6.8 SDI Camera connectors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-15 3.6.9 CVBS output connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-16 3.6.10 SDI video output connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-16 3.6.11 RS-232/RS-422 control connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-16 3.6.12 Mains power supply input socket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-17 3.6.13 Auxiliary connector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-17 3.6.14 DC power output connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-18 3.6.15 Multicore connector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-18

LDK 5481 + LDK 4700 User’s Guide | DigiLink system

1-1 Chapter 1 DigiLink system 1.1 Introduction The DigiLink system consists of a camera adapter (LDK 5481) and a base unit (LDK 4700) for use with Grass Valley standard definition (SD) camera heads. The system features digital signal processing and digital transmission of all signals between the camera head and base unit to ensure there is no loss of quality. As well as delivering high-quality 10-bit SDI video and audio of CD quality, the bidirectional digital transmission system carries teleprompter, external video for viewfinder, intercom, control and tally signals, embedded genlock and private data signals. All these signals are embedded in the SDI signal streams. The flexible system configuration makes DigiLink the ideal companion for LDK cameras in many environments. Depending on the application and cable lengths needed, the system can utilize low-cost coax cables or existing multicore cables. Typical applications for DigiLink include educational use or small studios such as local TV stations, continuity or announcement studios. It is also ideal for use in conference and parliamentary systems or in high-end surveillance. The camera with DigiLink adapter can also operate as a stand-alone unit by using its VTR output. 1.2 Accessories The following DigiLink accessories are available: RS-232 powerline cable LDK 8120/02, LDK 8120/10, LDK8120/25 RS-422 powerline cable LDK 8121/02, LDK 8120/10, LDK8120/25 Headset dynamic XLR-5 with double muff LDK 8111/37 DC power supply 100W 2-out LDK 5901/00 Local Control Panel LCP 100 LDK 5201 Operational Control Panel OCP 400 LDK 4640/10

LDK 5481 + LDK 4700 User’s Guide | DigiLink system

1-2 1.3 Compatibility If you wish to control your camera locally, you can connect an OCP 400 to the RS-232 connector of the camera. When an OCP 400 panel is used with the DigiLink system, C2IP functions (e.g. file management) are not supported by the system. ☞ Note The LDK 5481 adapter is backwards compatible with existing LDK 5480 breakout boxes and can be connected to them as described in the LDK 5480 User’s Guide.

LDK 5481 + LDK 4700 User’s Guide | DigiLink system

1-3 1.4 Configurations 1.4.1 Digilink system SDI coax configuration A camera head with an LDK 5481 adapter can be connected to the LDK 4700/00 base unit using two coax SDI cables. The maximum length of cable that can be used is 250m (820 ft). High quality coax cable should be used (for example, Belden 1694A). The DC power supply for the camera is supplied directly to the adapter by an optional local power supply or by the base unit (using a DC power cable). Figure 1-1. DigiLink system SDI coax connection When a DC power cable is used to power the camera from the base unit, refer to section 6 for the pin layout of the DC connectors. The maximum length of the cable depends on the type of cable and the power used by the camera. The table below is an indication of the cable lengths that can be used. Table 1-2. cable length indication for DC power cable ☞ Note Always use a power cable from the portable power cables category, type W, G, G-GC or PPE. The cable should be listed in accordance with NEC article 400 of ANSI/NFPA70. cable type cross section max. length (3A/40W) max. length (5A/60W) AWG 20 0.75 mm2 50 m 30 m AWG 18 1.0 mm2 75 m 45 m AWG 16 1.3 mm2 125 m 75 m SD Camera head LDK 5481 DigiLink Adapter Ready On-ai r Clear ND1/4 ND1/16 ND1/64 Clear Star 4P Star 6P Soft Focus Smart card Power on P wel 1 2 3 4 A B C D 2x coax cable max. length 250m. (820ft.) optional DC power cable LDK 4700/10 DigiLink Base Unit OCP 400/10 RS-422 with powerline LDK8121/xx max. length 25m. (82ft.) mains power optional LDK 5901 DC power supply

LDK 5481 + LDK 4700 User’s Guide | DigiLink system

1-4 1.4.2 DigiLink system multicore configuration A camera head with an LDK 5481 adapter can be connected to the LDK 4700/10 base unit using multicore cable. The maximum length of cable that can be used is 75m (250 ft). The base unit can supply power for the camera via the multicore cable. The power consumption of the camera may reduce the maximum length of cable that can be used, so alternatively, the power for the camera can be supplied directly to the adapter from the optional LDK 5901 power supply. ☞ Note Always use a listed 26-pin CCZ-A multicore cable compliant with EBU N21 (for example, Draka multicore camera cable type 755-2 PVC.) Figure 1-3. DigiLink system multicore connection 1.4.3 Stand alone SDI coax configuration A camera head with an LDK 5481 adapter can be connected to a recorder unit using an SDI coax cable. Only the SDI signal is passed via the coax cable. The maximum length of cable that can be used is 300m (1000 ft). High quality coax cable should be used (for example, Belden 1694A). The DC power supply for the camera is supplied directly to the adapter. The LCP 100 can be connected directly to the camera. 26-pin CCZ-A Multicore cable max. length 75m (250ft.) SD Camera head LDK 5481 DigiLink Adapter Ready On-ai r Clear ND1/4 ND1/16 ND1/64 Clear Star 4P Star 6P Soft Focus Smart card Power on P wel 1 2 3 4 A B C D LDK 4700/10 DigiLink Base Unit OCP 400/10 RS-422 with powerline LDK8121/xx max. length 25m. (82ft.) mains power optional LDK 5901 DC power supply

LDK 5481 + LDK 4700 User’s Guide | DigiLink system

1-5 Figure 1-4. Stand alone SDI coax configuration 1.4.4 Stand alone multicore configuration A camera head with an LDK 5481 adapter can be connected to a recorder using a multicore cable. Power can be supplied by the recorder via the multicore cable or directly to the adapter itself. To avoid degradation in the video signal, the maximum cable length is restricted to 5m (17 ft.) when the component outputs are used in the recorder. The LCP 100 can be connected directly to the camera. If the recorder uses the SDI signals, then the maximum length of cable depends on the ability of the recorder unit to supply sufficient power to the camera. When the adapter is powered directly the maximum length is 100m (330ft). With minimum power supplied from the recorder unit the maximum length is 25m (80ft). ☞ Note Always use a listed 26-pin CCZ-A multicore cable compliant with EBU N21 (for example, Draka multicore camera cable type 755-2 PVC) Figure 1-5. Stand alone multicore configuration SDI coax cable SD Camera head LDK 5481 DigiLink Adapter Clear ND1/4 ND1/16 ND1/64 Clear Star 4P Star 6P Soft Focus Smart card Power on P wel 1 2 3 4 A B C D Video recorder LCP 100 LCP 100 local control panel VTR on/off Operate VTR start/stop Gain Black Function ! Batt Tape nd/re optional LDK 5901 DC power supply 26-pin CCZ-A Multicore cable SD Camera head LDK 5481 DigiLink Adapter Clear ND1/4 ND1/16 ND1/64 Clear Star 4P Star 6P Soft Focus Smart card Power on P wel 1 2 3 4 A B C D Video recorder LCP 100 LCP 100 local control panel VTR on/off Operate VTR start/stop Gain Black Function ! Batt Tape nd/re optional LDK 5901 DC power supply

LDK 5481 + LDK 4700 User’s Guide | DigiLink system

1-6 1.5 Intercom An intercom channel connects the base unit to the camera operator's headset. The operator's intercom microphone signal is sent to the base unit. The headset can be connected to the 5 pin XLR headset connector at the back of the DigiLink adapter. For the connector and detailed pin descriptions refer to chapter 2.7.6. A conversation is started when the camera operator presses the VTR Start button at the front of the camera or the VTR button on the lens. The function and behaviour of this button can be defined in the INSTALL menu of the camera. Refer to the camera’s user’s guide. The volume of the headset earmuffs can be adjusted by turning the audio volume knob at the front (right side) of the camera. Intercom configuration The sidetone volume level (feedback signal from the microphone to the earmuffs) can be adjusted withthe INSTALL/INTERCOM/SIDETONE function n the camera (available only when a 4-wire connection is used). Depending on the type of microphone the following items can be set in the INSTALL/ INTERCOM menu in the camera: • Microphone gain level (0 or +40 dB) with the CAM.MIC_GAIN function; • Microphone power can be switched on or off with the CAM.MIC_POWER function. Both 2-wire and 4-wire intercom connections can be used. On the base unit, set the setup switch S1 in the Off-position when a 4-wire connection is used and set it in the On-position when a 2-wire connection is used. Refer to chapter 3.6.1 for the description of the setup switch. The following figure gives an overview of the routing of the intercom. For the connector and detailed pin descriptions refer to chapter 3.5. Figure 1-6. Schematic overview of the intercom routing DigiLink adapter DigiLink base unit Cam SDI OUT PROD out (4-wire) PROD in/out (2-wire) 0 dBu pin 1,9 return PROD in (4-wire) 0 dBu pin 5, 13 return SDI EXT TP Cam Video 0 / 40 dB front volume Cam SDI IN S1 Off = 4-wire S1 On = 2-wire 2 w. 4 w. EXT/TP video Out 0 dBu Mic in -24/-64 dBu

LDK 5481 + LDK 4700 User’s Guide | LDK 5481 DigiLink Adapter

2-1 Chapter 2 LDK 5481 DigiLink Adapter Important information (English) Read this information carefully before installing or servicing this equipment and retain them for future reference. Read and comply with the warning and caution notices that appear in the manual. Any changes or modifications not expressly approved in this manual could void your authority to operate this equipment. Safety Summary This informaton is intended as a guide for trained and qualified personnel who are aware of the dangers involved in handling potentially hazardous electrical/electronic equipment. It is not intended to contain a complete list of all safety precautions which should be observed by personnel in using this or other electronic equipment. The installation of this equipment involves risks both to personnel and equipment and must be performed only by qualified personnel exercising due care. During installation and operation of this equipment, local building safety and fire protection standards must be observed. Whenever it is likely that safe operation is impaired, the apparatus must be made inoperative and secured against any unintended operation. The appropriate servicing authority must then be informed. For example, safety is likely to be impaired if the apparatus fails to perform the intended function or shows visible damage. Warnings Warnings indicate danger that requires correct procedures or practices to prevent death or injury to personnel. • Do not modify this equipment. • Installation of this equipment must only be performed by qualified personnel. • Do not use any accessories other than those recommended by the manufacturer. • In case of an emergency ensure that the power is disconnected.

LDK 5481 + LDK 4700 User’s Guide | LDK 5481 DigiLink Adapter

2-2 • There are no user servicable parts inside. Refer servicing to qualified personnel only or contact your local Grass Valley representative. Cautions Cautions indicate procedures or practices that should be followed to prevent damage or destruction to equipment or property. • Always switch off the camera before changing the power supply. • Be extremely careful with the connectors between the camera head and the adapter. Do not allow the guide pins to damage the pins of the connector. Follow these steps in the order given. Tightening the screws in the wrong order could result in mechanical damage to the camera. Loosening the screws in the wrong order could result in mechanical damage to the camera. • To prevent risk of overheating, ventilate the units correctly. • Do not subject the unit to severe shocks or vibration. • Do not expose the unit to extremes of temperature. • Do not leave the unit in direct sunlight or close to heating appliances for extended periods. • Avoid very damp places. If the environment is wet or damp a rain cover must be used to protect the unit. Wichtige Hinweise (Deutsch) Lesen Sie bitte diese Hinweise genau bevor Sie diese Apparatur installieren und erhalten Sie Sie für künftiges Nachslagen. Beachten und Lesen Sie alle mit “Achtung” und “Vorsicht” gekennzeichneten Warnhinweise. Änderungen haben zur Folge, dass die Garantie ungültig wird und der Benutzer für etwaige durch die veränderte Ausrüstung verursachte Störungen haftbar gemacht werden könnte. Sicherheit (Zusammenfassung) Diese Informationen sind als Leitfaden für qualifiziertes Fachpersonal gedacht, das die Gefahren beim Umgang mit potenziell gefährlicher elektrischer/elektronischer Ausrüstung kennt. Es handelt sich dabei nicht um eine vollständige Zusammenstellung aller Sicherheitsvorkehrungen, die beim Gebrauch dieser oder anderer elektronischer Geräte zu beachten sind. Die Montage, Wartung und Instandsetzung dieser Ausrüstung ist mit Risiken für Personal und Ausrüstung verbunden und darf nur von qualifiziertem Personal vorgenommen werden, wobei mit der nötigen Sorgfalt vorzugehen ist. Mit der Montage, Bedienung, Instandhaltung oder Instandsetzung dieser Ausrüstung betrauten Personen wird dringend geraten, sich mit der Theorie und Praxis der Ersten Hilfe vertraut zu machen. Beim Einbau und Betrieb dieser Ausrüstung müssen die örtlichen Gebäudesicherheits- und Brandschutzvorschriften beachtet werden. Vor dem Anschluss der Ausrüstung an die Stromversorgung der Anlage muss überprüft werden, ob der Schutzleiter intakt ist.

LDK 5481 + LDK 4700 User’s Guide | LDK 5481 DigiLink Adapter

2-3 Wenn eine Beeinträchtigung des sicheren Betriebs wahrscheinlich ist, muss das Gerät außer Betrieb gesetzt und gegen ungewollten Betrieb gesichert werden. Dann muss der zuständige Kundendienst benachrichtigt werden. Eine Beeinträchtigung der Sicherheit ist zum Beispiel dann wahrscheinlich, wenn das Gerät nicht wie vorgesehen funktioniert oder einen sichtbaren Schaden aufweist. Vorsicht! Mit “Vorsicht” wird auf eine Gefahr hingewiesen, die korrekte Arbeits- oder Verfahrensweisen erfordert, um Tod oder Verletzung zu verhindern. • An dieser Ausrüstung dürfen keine Änderungen vorgenommen werden; • Die Montage dieser Ausrüstung darf nur von Fachpersonal vorgenommen werden; • Es sollen nur von den Hersteller empfohlene Zubehöre verwendet werden; • Bei Eintreten eines Notfalls unbedingt die Stromzufuhr abschalten; • Dieses Produkt enthält keine Anwenderteile. Reparatur und Wartung nur von qualifiziertem Fachpersonal vornehmen lassen oder nehmen Sie Kontakt auf mit Ihrem Grass Valley Vertretene; Achtung! Mit “Achtung” werden Arbeitsanweisungen gekennzeichnet, die zu befolgen sind, um eine Beschädigung oder Zerstörung der Ausrüstung bzw. von Eigentum zu verhindern. • Die Kamera vor dem Wechsel der Stromversorgung immer ausschalten; • Stecker zwischen Kamerakopf und Adapter mit äußerster Vorsicht handhaben. Darauf achten, dass die Steckerstifte nicht durch die Führungsstifte beschädigt werden. • Um einer Überhitzungsgefahr vorzubeugen, ist das Produkt korrekt zu belüften; • Dieses Produkt darf nicht an extremen stöße oder Zittern ausgesetzt werden; • Dieses Produkt darf nicht an extremen Temperaturen ausgesetzt werden; • Nicht langfristig in direktem Sonnenlicht oder in der Nähe von Heizgeräte zurücklassen. • Vermeide feuchtigen Plätze. Wenn die Umgebung nass oder feucht ist, muss ein Regenüberzug verwendet werden um das Gerät zu schützen.

LDK 5481 + LDK 4700 User’s Guide | LDK 5481 DigiLink Adapter

2-4 2.1 Specifications 2.2 Dimensions Figure 2-1. LDK 5481 DigiLink adapter dimension sketch Item Value Power requirements 12 VDC Power consumption 12 W Power input 12 VDC XLR-4 male (or multicore cable) Power output 12 VDC 1.5A; 4-pin Hirose SDI Video output SMPTE 259M, 0.8 Vpp, 270Mb/s; 75 Ohm; BNC SDI Video input SMPTE 259M, 0.8 Vpp, 270Mb/s; 75 Ohm; BNC CVBS out (VF/EXT/TP) 1 Vpp; 75 Ohm; BNC Viewfinder out (CVBS/EXT/TP) 1 Vpp; 75 Ohm; BNC Multicore connection 26-pin EBU N21 multicore connector LCP connector for connecting an LCP 100 local control panel; 12-pin Hirose Operating temperatures -20 to +45°C (-4 to +113°F) Storage temperatures -20 to +60°C (-4 to +140°F) Weight (approx.) 1.5 kg Dimensions 105(L) x 120(W) x 225(H) mm without handgrip

LDK 5481 + LDK 4700 User’s Guide | LDK 5481 DigiLink Adapter

2-5 2.3 Compatibility Before using the LDK 5481 DigiLink adapter you must ensure that it is compatible with your camera head. Camera heads with software version v13.0 and higher are fully compatible and do not need to be upgraded. Camera heads with software below this version must be updated. Older camera heads with data board no. 3922 406 84271 or LDK 100 cameras built before 2001 need to be upgraded. For more information on upgrading your camera contact your Grass Valley service representative. 2.4 Controls Figure 2-2. LDK 5481 adapter controls 2.4.1 Powering the camera The power supply for the camera and the adapter (+12 Vdc) is normally supplied either via the multicore connector or via the DC IN socket. Set the power source selection switch (1) to the position that corresponds to your chosen method: • LOC: Powered via DC IN socket • REM:Powered via multicore The power on indicator (2) lights when power is supplied and the camera power switch is On. DC out LCP CVBS VF 2 4 3 1 1. Power source selection switch 2. Power on indicator (green) 3. Tally indicators (red) 4. Circuit breaker button (FUSE)

LDK 5481 + LDK 4700 User’s Guide | LDK 5481 DigiLink Adapter

2-6 If excessive current flows in the camera or adapter, the circuit breaker (4) trips and shuts off power to all the units. If this happens, check the units for faults and if necessary take corrective action before pressing the circuit breaker button to reset the power. 2.5 Attaching the LDK 5481 adapter to a camera head The LDK 5481 adapter is shorter than a standard adapter. Before attaching the LDK 5481 adapter to a camera, the carrying handle must be re-positioned on the camera head using the mounting bracket supplied with the adapter. To re-position the carrying handle for a short adapter, proceed as follows: 1. Remove the viewfinder and any other adapter attached to the camera. 2. Unscrew and remove the two screws that attach the front of the carrying handle to the camera. (For the LDK 500: tilt the carrying handle backwards and use your fingertips to gently unplug the flat cable that connects the zoom control to the connector inside the camera body.) ☞ Note The digital zoom control of the LDK 500 cannot be used in combination with the LDK 5481 adapter. An optional analogue zoom control LDK 6113 can be used. 3. Remove the carrying handle from the camera. 4. Use the supplied screws and washers to attach the mounting bracket to the top of the camera. (Use the screw holes where the handle was previously attached.) Figure 2-1. Carrying handle replacement 5. For LDK 500: fold the flat cable away into the hollow part of the carrying handle. 6. Place the carrying handle into the recess at the front of the mounting plate and use the two original screws to secure it in place. 7. Attach the LDK 5481 adapter to the camera (refer to section “Attaching an adapter” in the User’s Guide of your camera for further instructions). Clea r ND1/4 ND1/16 ND1/64 Clear Star 4P Star 6P Soft Focus VT R Save Ext. Iris Std. File Power On 1 2 3 4 A B C D Smart card (2x) Power Off Clea r ND1/4 ND1/16 ND1/64 Clear Star 4P Star 6P Soft Focus VT R Save Ext. Iris Std. File Power on 1 2 3 4 A B C D Smart card (2x) Power Off Clea r ND1/4 ND1/16 ND1/64 Clear Star 4P Star 6P Soft Focus VT R Save Ext. Iris Std. File Power On Off 1 2 3 4 A B C D Smart card Power (2x)

LDK 5481 + LDK 4700 User’s Guide | LDK 5481 DigiLink Adapter

2-7 2.6 Mounting a script board To attach the optional script board (LDK 6985/21) to the adapter use the special bracket and screws delivered with the script board. To attach the bracket to the adapter, proceed as follows: 1. Unscrew and remove the four screws attaching the viewfinder holder to the top of the adapter. 2. Place the viewfinder holder on top of the script board bracket and align the screw holes. 3. Using the four long screws provided, attach the holder and bracket to the top of the adapter. Figure 2-3. Script board accessory 4. The script board can now be mounted onto the bracket. script board holder viewfinder holder

LDK 5481 + LDK 4700 User’s Guide | LDK 5481 DigiLink Adapter

2-8 2.7 Adapter connectors Figure 2-4. DigiLink adapter connector location 2.7.1 SDI video output connector Figure 2-5. SDI video output connector DC out LCP CVBS VF Assignable (VF) output DC power output DC power supply input Assignable (CVBS) output LCP control unit SDI video output connector Multicore connector Script light output Headset connector SDI video input connector This BNC connector supplies an SDI video output signal (Y/Cr/Cb 4:2:2) that also includes embedded audio, intercom and private data signals. BNC connector: panel view (X8)

LDK 5481 + LDK 4700 User’s Guide | LDK 5481 DigiLink Adapter

2-9 2.7.2 SDI video input connector Figure 2-6. SDI video input connector 2.7.3 Multicore connector Figure 2-7. Multicore connector This BNC connector receives an SDI video input from the base unit. Reference, teleprompter and external video signals are embedded in the stream together with intercom, control and private data signals. BNC connector: panel view (X9) 1 11 10 12 14 B 16 17 18 21 22 A 23 24 19 20 15 13 8 9 2 7 6 4 5 3 A.+ Battery from VTR (+10.7 to +17V) B.- Battery Ground 1. SDI 2. SDI Return 3. Y Return 4. Y 5. Pr: NTSC 700mV 75% saturated colour bar Cr: PAL 525mV (EBU N10) 6. Pr/Cr Return 7. Pb: NTSC 700mV 75% saturated colour bar Cb: PAL 525mV (EBU N10) 8. Pb/Cb Return 9. Cam. Mic. X 10. Cam. Mic. Y 11. Cam. Mic. shield 12. VTR start/stop: +5V = recording; 0V = stop 13. Batt. alarm 14. Power sense 15. Record/Tally 16. Genlock Video/BB return 17. Cable shield (Camera GND to VTR GND) 18. Playback video / Ext. VF 19. Playback video return / Ext. VF return 20. VTR Save 21. Genlock Video/BB 22. Spare 23. RXD, control 24. TXD, control 26-pin male; panel view Panel part number: (X6) 3922 040 02571 This multicore connector can be used to connect either a recorder or a base unit (LDK 4700/10). When connected to a recorder it provides the video outputs, control signals and the camera microphone signal. DC power can also be supplied to the camera via this connector. The connector accepts a playback video signal for display in the viewfinder. The start/stop control signal for an external recorder is also passed via this connector.

LDK 5481 + LDK 4700 User’s Guide | LDK 5481 DigiLink Adapter

2-10 2.7.4 Video signal (VF) output connector Figure 2-8. Video signal (VF) output connector 2.7.5 Video signal (CVBS) output connector Figure 2-9. Video signal (CVBS) output connector 2.7.6 Intercom headset connector Figure 2-10. XLR intercom headset connector This BNC socket provides a 1.0 Vpp analog output video signal. This signal can be assigned in the INSTALL menu of the camera. Either the VF, CVBS, EXT. or TP signal can be selected. By default the viewfinder signal is output. Markers and menus similar to those in the viewfinder can be superimposed on this signal. BNC connector: panel view This BNC socket provides a 1.0 Vpp analog output video signal. This signal can be assigned in the INSTALL menu of the camera. Either the VF, CVBS, EXT. or TP signal can be selected. By default the CVBS signal is output for viewing. BNC connector: panel view 4 1 2 3 5 1. Microphone return 2. Microphone 3. Telephone return 4. Telephone left 5. Telephone right Microphone level: -64 dBu / -24 dBu switchable Microphone impedance: >600 Ohm Telephone level: +6 dBu nominal Telephone output impedance: <50 Ohm XLR 5-pin female; panel view (X11)

LDK 5481 + LDK 4700 User’s Guide | LDK 5481 DigiLink Adapter

2-11 2.7.7 LCP / Fibre power connector Figure 2-11. LCP connector 2.7.8 DC power output socket Figure 2-12. DC power and tally output connector 4 6 1 9 2 10 5 8 3 11 12 7 This connector is used to connect an LCP control panel (LDK 5201) to the camera. 1. - 2. RS-232 RXD 3. RS-232 TXD 4. Private data IN (Camera to base unit) 5. GND 6. - 7. Private data OUT (base unit to Camera) 8. - 9. +Batt 10. SDA 11. SCL 12. Housing Hirose 12-pin female; panel view Panel part number: (X5) 2422 026 04355 4 1 2 3 1. Power ground 2. On air (+5V, 100 Ohm) 3. Housing 4. +12 Vdc (max. 18W) Shield of cable directly to the connector housing. The socket provides access to an internal tally switch. When the camera is on-air, the contact of the internal relay is closed. Hirose 4-pin female; panel view Panel part number: (X3) 2422 026 04675

LDK 5481 + LDK 4700 User’s Guide | LDK 5481 DigiLink Adapter

2-12 2.7.9 DC power input socket Caution The input voltage must not exceed +17 Vdc. Figure 2-13. DC power input connector 2.7.10 Script light power supply socket Figure 2-14. Script light power supply output connector 4 1 2 3 1. Power ground 2. -Batt sense 3. +Batt sense 4. +10.5 Vdc . . . +17 Vdc This socket accepts a DC voltage of 12V nominal. Maximum power consumption 60W. XLR 4-pin male: panel view (X7) 3 1 2 1. +12 Vdc (maximum dissipation 3W) 2. Power return 3. Shield Fischer 3-pin female: panel view Panel connector number: (X4) 3922 040 02881

LDK 5481 + LDK 4700 User’s Guide | LDK 5481 DigiLink Adapter

2-13 2.8 Install menu The functions shown in the table below appear in the INSTALL menu of the camera head when an LDK 5481 adapter is attached. Refer to the User’s Guide of the camera head for more information on accessing this menu. Main menu items Purpose Disable Camera on/off IR receiver on/off OnAir Lamp on/off Intercom set intercom values Audio set gain and filter Timing set subcarrier and h-phase Notch on/off Aspect ratio select aspect ratio values Exposure set lighting and clear scan values Gain preset set gain preset values Quick Smart Touch on/off Buttons assign functions to buttons Video output assign YCrCb or RGB to VTR output CVBS output assign CVBS, EXT, TP or VF to CVBS output VF output assign CVBS, EXT, TP or VF to VF output

LDK 5481 + LDK 4700 User’s Guide | LDK 4700 base unit

3-1 Chapter 3 LDK 4700 base unit Important information (English) Read this information carefully before installing this equipment and retain them for future reference. Read and comply with the warning and caution notices that appear in the manual. Any changes or modifications not expressly approved in this manual could void your authority to operate this equipment. Safety Summary This informaton is intended as a guide for trained and qualified personnel who are aware of the dangers involved in handling potentially hazardous electrical/electronic equipment. It is not intended to contain a complete list of all safety precautions which should be observed by personnel in using this or other electronic equipment. The installation of this equipment involves risks both to personnel and equipment and must be performed only by qualified personnel exercising due care. During installation and operation of this equipment, local building safety and fire protection standards must be observed. Before connecting the equipment to the power supply of the installation, the proper functioning of the protective earth lead of the installation needs to be verified. Whenever it is likely that safe operation is impaired, the apparatus must be made inoperative and secured against any unintended operation. The appropriate servicing authority must then be informed. For example, safety is likely to be impaired if the apparatus fails to perform the intended function or shows visible damage. Warnings Warnings indicate danger that requires correct procedures or practices to prevent death or injury to personnel. • Do not modify this equipment; • Installation of this equipment must only be performed by qualified personnel; • Do not use any accessories other than those recommended by the manufacturer; • In case of an emergency ensure that the power is disconnected;

LDK 5481 + LDK 4700 User’s Guide | LDK 4700 base unit

3-2 • Mount equipment so that power lead can be accessed to disconnect power; • Any interruption of the protection conductor inside or outside the apparatus, or disconnection of the protective earth terminal, is likely to make the apparatus dangerous. Intentional interruption is prohibited; • Use only fuses of the type and rating specified; • To prevent fire or shock hazard, do not expose the unit to rain or moisture; • There are no user servicable parts inside. Refer servicing to qualified personnel only or contact your local Grass Valley representative; • Observe local building safety, fire protection and electrical installation standards during installation and operation of this equipment; • Before connecting the equipment to the power supply of the installation, verify the proper functioning of the protective earth lead; • Whenever it is likely that safe operation is impaired, the apparatus must be made inoperative and secured against any unintended operation. Cautions Cautions indicate procedures or practices that should be followed to prevent damage or destruction to equipment or property. • Do not subject the unit to severe shocks or vibration; • Do not expose the unit to extremes of temperature; • To prevent risk of overheating, ventilate the product correctly; • Connect the product only to a power source with the specified voltage rating. Wichtige Hinweise (Deutsch) Lesen Sie bitte diese Hinweise genau bevor Sie diese Apparatur installieren und erhalten Sie Sie für künftiges Nachslagen. Beachten und Lesen Sie alle mit “Achtung” und “Vorsicht” gekennzeichneten Warnhinweise Änderungen haben zur Folge, dass die Garantie ungültig wird und der Benutzer für etwaige durch die veränderte Ausrüstung verursachte Störungen haftbar gemacht werden könnte. Sicherheit (Zusammenfassung) Diese Informationen sind als Leitfaden für qualifiziertes Fachpersonal gedacht, das die Gefahren beim Umgang mit potenziell gefährlicher elektrischer/elektronischer Ausrüstung kennt. Es handelt sich dabei nicht um eine vollständige Zusammenstellung aller Sicherheitsvorkehrungen, die beim Gebrauch dieser oder anderer elektronischer Geräte zu beachten sind. Die Montage, Wartung und Instandsetzung dieser Ausrüstung ist mit Risiken für Personal und Ausrüstung verbunden und darf nur von qualifiziertem Personal vorgenommen werden, wobei mit der nötigen Sorgfalt vorzugehen ist.

LDK 5481 + LDK 4700 User’s Guide | LDK 4700 base unit

3-3 Mit der Montage, Bedienung, Instandhaltung oder Instandsetzung dieser Ausrüstung betrauten Personen wird dringend geraten, sich mit der Theorie und Praxis der Ersten Hilfe vertraut zu machen. Beim Einbau und Betrieb dieser Ausrüstung müssen die örtlichen Gebäudesicherheits- und Brandschutzvorschriften beachtet werden. Vor dem Anschluss der Ausrüstung an die Stromversorgung der Anlage muss überprüft werden, ob der Schutzleiter intakt ist. Wenn eine Beeinträchtigung des sicheren Betriebs wahrscheinlich ist, muss das Gerät außer Betrieb gesetzt und gegen ungewollten Betrieb gesichert werden. Dann muss der zuständige Kundendienst benachrichtigt werden. Eine Beeinträchtigung der Sicherheit ist zum Beispiel dann wahrscheinlich, wenn das Gerät nicht wie vorgesehen funktioniert oder einen sichtbaren Schaden aufweist. Vorsicht! Mit “Vorsicht” wird auf eine Gefahr hingewiesen, die korrekte Arbeits- oder Verfahrensweisen erfordert, um Tod oder Verletzung zu verhindern. • An dieser Ausrüstung dürfen keine Änderungen vorgenommen werden; • Die Montage dieser Ausrüstung darf nur von Fachpersonal vorgenommen werden; • Es sollen nur von den Hersteller empfohlene Zubehöre verwendet werden; • Bei Eintreten eines Notfalls unbedingt die Stromzufuhr abschalten; • Ausrüstung so montieren, daß das Netzkabel zum Abschalten der Stromzufuhr zugänglich ist; • Jede Unterbrechung des Schutzleiters innerhalb oder ausserhalb des Geräts oder Trennung der Schutzleiter-anschlussklemme Könnte das Gerät fefährlich machen. Eine absichtliche Unterbrechung ist untersagt; • Es dürfen nur Sicherungen des vorgeschriebenen Typs und Nennwerts verwendet werden; • Um Feuer oder Schlaggefahr vorzubeugen, soll das Produkt nie an Regen oder Feucht ausgesetzt werden; • Dieses Produkt enthält keine Anwenderteile. Reparatur und Wartung nur von qualifiziertem Fachpersonal vornehmen lassen oder nehmen Sie Kontakt auf mit Ihrem Grass Valley Vertretene; • Beim Einbau und Betrieb dieser Ausrüstung müssen die örtlichen Gebäudesicherheits- und Brandschutzvorschriften beachtet werden; • Vor dem Anschluss der Ausrüstung an die Stromversorgung der Anlage muss überprüft werden, ob der Schutzleiter intakt ist; • Wenn eine Beeinträchtigung des sicheren Betriebs wahrscheinlich ist, muss das Gerät außer Betrieb gesetzt und gegen ungewollten Betrieb gesichert werden. Achtung! Mit “Achtung” werden Arbeitsanweisungen gekennzeichnet, die zu befolgen sind, um eine Beschädigung oder Zerstörung der Ausrüstung bzw. von Eigentum zu verhindern. • Dieses Produkt darf nicht an extremen stöße oder Zittern ausgesetzt werden; • Dieses Produkt darf nicht an extremen Temperaturen ausgesetzt werden;

LDK 5481 + LDK 4700 User’s Guide | LDK 4700 base unit

3-4 • Um einer Überhitzungsgefahr vorzubeugen, ist das Produkt korrekt zu belüften; • Das Produkt darf nur an eine Stromquelle mit der vorgeschriebenen Nennspannung angeschlossen werden. 3.1 Installation information 3.1.1 Ventilation Cold air is taken in from the right side and expelled on the left side (see drawing). • Do not block the air inlet or outlet; • Clean the air inlet grill at least once a year. 3.1.2 Rack mounting instructions Note that rack mounting is not mandatory for the unit. When the unit is mounted in a 19” rack ensure that the following instructions are observed: • The unit is supported at the rear; • If installed in a closed or multi-rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tmax) specified; • Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipement is not compromised; • Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading; • Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern; • Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g. use of power strips). hot air Front cold air

LDK 5481 + LDK 4700 User’s Guide | LDK 4700 base unit

3-5 3.1.3 Installation notices For proper installation the following NEC articles should be noticed: Regarding communication circuits: – Installation of equipment (article 800.18). Regarding radio and television equipment: – Avoid contact with conductors of other systems (article 810.13); – Provide extensive, separate clearance requirements for indoor and outdoor locations (article 810.18). 3.1.4 Mains power supply chord General By default, a mains power supply chord is not shipped with the device. To connect the LDK 4700 base unit to the mains the following power supply cord is advised: type H03 VV-F or H03 VVH2-F flexible wire: 1 mm², 250V / 10A minimum or 16 AWG. When the device is installed in one of the following countries the power chord must be compliant to the indicated specifications and regulations indicated below: For Denmark Supply cord of single-phase equipment having a rated current not exceeding 10A shall be provided with a plug according to the Heavy Current Regulations section 107-2-D1. Class I equipment provided with socket-outlets with earth contact or which are intended to be used in locations where protection against indirect contact is required according to the wiring rules shall be provided with a plug in accordance with standard sheet DK 2-1a or DK 2-5a. For Ireland Apparatus which is fitted with a flexible cable or cord and is designed to be connected to a mains socket conforming to I.S. 411 by means of that flexible cable or cord and plug, shall be fitted with a 13A plug in accordance with Statutory Instrument 525:1997 - National Standards Authority of Ireland (section 28) (13A plugs and Conversion Adaptors for Domestic Use) Regulations, 1997. For Spain Supply cords of single-phase equipment having a rated current not exceeding: – 10A shall be provided with a plug according to UNE 20315:1994 CLASS I EQUIPMENT provided with socket-outlets with earth contacts, or which are intended to be used in locations where protection against indirect contact is required according to the wiring rules, shall be provided with a plug in accordance with UNE 20315:1994 For Switzerland Supply cords of equipment having a rated current not exceeding 10A shall be provided vwith a plug complying with SEV 1011 or IEC 884-1 and the following dimension sheet: – SEV 6534-2.1991 Plug Type 12: L+N+PE250V 10A

LDK 5481 + LDK 4700 User’s Guide | LDK 4700 base unit

3-6 For the UK Apparatus which is fitted with a flexible cable or a cord and is designed to be connected to a mains socket conforming to BS 1363 by means of that flexible cable or cord and plug, shall be fitted with a "standard plug" in accordance with Statutory Instrument 1786: 1994 - The Plugs and Sockets etc. (Safety) Regulations 1994, unless exempted by those regulations. Note: "Standard plug" is defined in SI 1786:1994 and essentially means an approved plug conforming to BS 1363 or an approved conversion plug. For the US Listed, detachable, maximum 4.5 m (14.76 ft.) long; rated minimum 125V, 10A, type SJT or type SVT flexible cord; one end terminates in NEMA 5-15P or 5-20P groundingtype attachment plug, other end in appliance coupler. Listed, detachable, maximum 4.5 m (14.76 ft.) long; rated minimum 250V, 10A, type SJT or type SVT flexible cord; one end terminates in NEMA 6-15P or NEMA 6-20P grounding-type attachment plug, other end in appliance coupler.

LDK 5481 + LDK 4700 User’s Guide | LDK 4700 base unit

3-7 3.2 Specifications The base unit is available in two versions: • The LDK 4700/00 version has a 26-pin multicore connector for use with a multicore cable connection to the DigiLink adapter; • The LDK 4700/10 version has two SDI coax connectors and a DC power output to connect to the DigiLink adapter using coaxial cables. When ordering, you specify the version you require. Item Value Power requirements 100 to 240 VAC (-10% / +6%) 50 to 60 Hz Power consumption 200 VA Y, Pr, Pb out 1 Vpp; 75 Ohm; BNC Audio out XLR-3 male CVBS out (x2) 1 Vpp; 75 Ohm; BNC Teleprompter in 1 Vpp; 75 Ohm; BNC looped-through Reference in 1 Vpp; 75 Ohm; BNC looped-through External video signal in 1 Vpp; 75 Ohm; BNC looped-through Control unit D-sub 9-pin RS422 connection for OCP 400 Intercom 2/4-wire via 15-pin male D-connector Signalling On-air, call via 15-pin male D-connector Auxiliary data Private data via 15-pin male D-connector Operating temperatures 0 to +45°C (32 to +113°F) Storage temperatures -20 to +60°C (-4 to +140°F) Weight (approx.) 6 kg Dimensions 255 (L) x 483 (W) x 44 (H) mm (19-inch rack, 1 unit high) LDK 4700/00 version DigiLink connection 26-pin multicore connector LDK 4700/10 version Coaxial SDI connectors (x2) SMPTE 259M, 0.8 Vpp, 270Mb/s; 75 Ohm; BNC Auxiliary connection 12-pin Hirose Power output DC output; XLR-4 female

LDK 5481 + LDK 4700 User’s Guide | LDK 4700 base unit

3-8 3.3 Dimensions Figure 3-1. LDK 4700 DigiLink base unit dimension sketch Ready On-air 438 mm 483 mm 465 mm 255 mm 44 mm

LDK 5481 + LDK 4700 User’s Guide | LDK 4700 base unit

3-9 3.4 Controls and indicators Figure 3-1. DigiLink base unit controls 3.4.1 Powering the base unit Set the power switch to the on position (I). The power on indicator in the switch lights when the unit is powered. 3.4.2 Indicators Table 3-2. Ready indicator Table 3-3. On-Air indicator 3.4.3 Set-up items There are five items that can be accessed via the set-up buttons: • Camera number (CA) • Subcarrier adjustment (SC) • H-phase (HP) • Status (ST) • Menu Off (OF) Ready On-air Mains DigiLinK - BASE UNIT LDK 4700 Power switch and indicator Set-up buttons On-air indicator Display Ready indicator indication description off no camera video signal detected. green (OK) camera video signal detected. flashing yellow no camera video signal detected and power failure or fan failure. flashing yellow/green camera video signal detected and power failure or fan failure. indication description On The camera is on air. Off The camera is not on air.

LDK 5481 + LDK 4700 User’s Guide | LDK 4700 base unit

3-10 Press the up or down button to display the required item. Press the select button to select it. The display shows the abbreviation of the current item. Camera Number (CA) When CA is displayed, push the select button to enter the selection mode. Press the up or down button to select an available camera number. Push the select button to set the new camera number. The new camera number is shown in the display. Subcarrier (SC) When SC is displayed, push the select button to enter the Subcarrier adjustment mode. Press the up or down button to shift the Subcarrier phase. If you continue to press a button, the shift change occurs in bigger steps. Push the select button to leave the Subcarrier adjustment mode. H-Phase (HP) When HP is displayed, push the select button to enter the H-Phase adjustment mode. Press the up or down button to shift the H-Phase (this is the fine control and changes are not visible on the display). If you press the button continuously, the shift change occurs in bigger steps (this is the coarse control; changes are shown on the display). Push the select button to leave the H-Phase adjustment mode. Status (ST) When ST is displayed, push the select button to enter the status mode. Press the up or down button to select SO (the software status) or FI (the firmware status). Push the select button to view the status number. Push the select button to leave the status mode. Menu Off (OF) This is the inactivity state of the menu OCP control The set-up buttons can be used to set up the base unit, however, it is more convenient to use the OCP connected to the base unit. (Refer to the OCP user guide to find out how to do this.)

LDK 5481 + LDK 4700 User’s Guide | LDK 4700 base unit

3-11 3.5 Connecting the studio signalling Connect the studio signalling system to the rear of the base unit. The wiring of the panel connector is shown below. Refer to the next chapter for the location of this connector. Figure 3-4. Signalling / Intercom / Auxiliary connector 3.5.1 Call and On-air signals There are two connection methods for the Call and On-air signalling functions: 1. Dry contact 2. Voltage level The connection method for the signalling functions is set by a jumper on the main board of the base unit. Remove the upper lid of the base unit and locate jumper X317 at the bottom centre of the board. The settings of the jumper are shown below: Figure 3-5. Jumper settings for signalling 4 1 2 3 5 6 7 8 9 10 11 12 13 14 15 1 2 3 4 5 6 On Side view of switches Off 1. Intercom PROD Out (4-wire) or Intercom PROD In/Out (2-wire) 2. Call send (dry contact to pin 10) 3. n.c. 4. On Air send (dry contact to pin 12) 5. Intercom PROD In 6. Private data In 7. Private data Out 8. Housing 9. Camera microphone Out return 10. Call return 11. n.c. 12. On Air return 13. Intercom PROD In return (4-wire) or not connected (2- wire) 14. n.c. 15. Common ground 15-pin male D-connector; panel view Panel part number: 2411 022 05292 A 4-wire (Off) or 2-wire (On) intercom system is selected with rocker switch number 1. + C A 12 D 19 B 26 5 + L1500 K6000 MP7502 X312 R6005 C9507 C7516 IC7503 C1500 IC9500 C9503 R9531 X317 R9532 R9533 R9536 R9534 MP2004 R5021 MP2000 R2024 C2005 C2039 R2019 R2023 R2022 C7513 C A dry contact voltage level D B C A D B

LDK 5481 + LDK 4700 User’s Guide | LDK 4700 base unit

3-12 Dry contact signalling Figure 3-6. Dry contact signalling Voltage level signalling Figure 3-7. Voltage level signalling External signaling dry contact base unit signalling connector +5 - 12 Vdc External signaling with DC output voltage + base unit signalling connector

LDK 5481 + LDK 4700 User’s Guide | LDK 4700 base unit

3-13 3.6 DigiLink base unit connectors Figure 3-2. DigiLink base unit connector location 3.6.1 Setup switches The rear of the base unit has six miniature rocker switches. The table below describes their function. Switch them On or Off as follows: 6 7 8 17 15 A 13 12 22 19 18 B 24 23 21 20 14 16 10 9 5 11 1 3 2 4 Audio RS422 1 . . . 6 Auxiliary Ext Ref TP Y Pb Pr SDI CVBS SDI Camera DC out Fiber aux Audio RS422 1 . . . 6 Auxiliary Ext Ref TP Y Pb Pr SDI CVBS Camera Power supply input Camera audio output Signalling Intercom Aux. connector External/ Reference/ Teleprompter inputs SDI Camera input and output CVBS outputs (x2) SDI outputs (x2) RS-422 connector Y / Pb / Pr Compontent soutputs External /Reference / Teleprompter loop- through connectors Auxiliary connector DC power output Camera 26p multicore connector LDK 4700/00 LDK 4700/10 Setup switches Table 3-8. base unit setup switches Switch Function On Off (default) 1 Intercom system type 2-wire 4-wire 2 Video output R, G, B Y, Pr, Pb 3 (not used) 4 (not used) 5 (not used) 6 Sub-D connector control RS-232 RS-422 1 2 3 4 5 6 On Side view of switches Off

LDK 5481 + LDK 4700 User’s Guide | LDK 4700 base unit

3-14 3.6.2 Audio out connector Figure 3-9. Audio out connector 3.6.3 Signalling / Intercom / Auxiliary connector 3.6.4 External video input connector Figure 3-10. External video input connector 3.6.5 Reference input connector Figure 3-11. Reference signal input connector 3 1 2 1. Audio Screen 2. Audio Out 3. Audio Return Sensitivity range: -64 dBu to -22 dBu Signal at pin 2 of audio output is in phase with signal at pin 2 of audio input. XLR 3-pin male; panel view Panel part number: (X338) 2422 026 02985 Apply a 1Vpp, 75 Ohm video signal to this BNC socket for viewing in the camera viewfinder (or via the VF/ CVBS BNC output socket). BNC connector: panel view Apply a 1Vpp, 75 Ohm genlock signal- (C)VBS or Black Burst) - to this BNC socket to synchronize the camera. BNC connector: panel view

LDK 5481 + LDK 4700 User’s Guide | LDK 4700 base unit

3-15 3.6.6 Teleprompter input connector Figure 3-12. Teleprompter input connector 3.6.7 Y, Pr, Pb output connectors Figure 3-13. Y, Pr, Pb output connectors 3.6.8 SDI Camera connectors Figure 3-14. SDI Camera connectors Apply a 1Vpp, 75 Ohm teleprompter video signal to this BNC socket for viewing on the camera VF output. (The signal output on the camera VF or CVBS output is selected in the camera menu system.) BNC connector: panel view These BNC sockets provides 1 Vpp Y, Pr and Pb component video output signals from the camera. These outputs can set to R, G and B with the rocker switch number 2 on the rear of the unit. Off is Y, Pr and Pb; On is R, G and B BNC connector: panel view 1 2 3 4 5 6 On Side view of switches Off 1. SDI (camera to base unit) 2. SDI (base unit to camera) BNC connector: panel view

LDK 5481 + LDK 4700 User’s Guide | LDK 4700 base unit

3-16 3.6.9 CVBS output connector Figure 3-15. CVBS output connector 3.6.10 SDI video output connectors Figure 3-16. SDI video output connectors 3.6.11 RS-232/RS-422 control connector Figure 3-17. RS-232/RS-422 control connector These two BNC sockets provide 1 Vpp CVBS analogue output video signals for viewing. BNC connector: panel view These two BNC connectors each supply an SDI video output (Y/Cr/Cb 4:2:2). BNC connector: panel view 5 4 3 2 1 9 8 7 6 SubD 9-pin female; panel view (X369) RS-232 (On) or RS-422 (Off) control protocol is selected with rocker switch number 6. 1 2 3 4 5 6 On Side view of switches Off RS-232 mode 1. nc 2. RXD 3. TXD 4. nDTR 5. DGND 6. nDSR 7. nRTS 8. nCTS 9. OCP Power RS-422 mode 1. GND 2. nRX 3. TX 4. GND 5. GND 6. GND 7. RX 8. nTx 9. OCP Power

LDK 5481 + LDK 4700 User’s Guide | LDK 4700 base unit

3-17 3.6.12 Mains power supply input socket Figure 3-18. Mains power supply input socket WARNING Use only 250V/10A power cables that conform to your local regulations. 3.6.13 Auxiliary connector Figure 3-19. Auxiliary connector 3 2 1 1. Neutral 2. Phase 3. Earth Mains input voltage: 100 - 240 VAC (auto ranging) Mains frequency: 50 to 60Hz Fuses: T2.5 AH250V Power consumption: 200W max. Euroconnector: panel view (X470) 4 6 1 9 2 10 5 8 3 11 12 7 1. - 2. RS-232 RXD 3. RS-232 TXD 4. Private data (base unit to camera) 5. GND 6. - 7. Private data (camera to base unit) 8. - 9. + Batt 10. SDA 11. SCL 12. Housing Hirose 12-pin female; panel view Panel part number: (X5) 2422 026 04355

LDK 5481 + LDK 4700 User’s Guide | LDK 4700 base unit

3-18 3.6.14 DC power output connector Figure 3-20. DC power output connector 3.6.15 Multicore connector Figure 3-21. Multicore connector 4 1 2 3 1. Power ground 2. -Batt sense 3. +Batt sense 4. +12 Vdc Maximum power consumption 60W. XLR 4-pin female: panel view (X7) 6 7 8 17 15 A 13 12 22 19 18 B 24 23 21 20 14 16 10 9 5 11 1 3 2 4 5. Pr: NTSC 700mV 75% saturated colour bar Cr: PAL 525mV (EBU N10) 6. Pr/Cr Return 7. Pb: NTSC 700mV 75% saturated colour bar Cb: PAL 525mV (EBU N10) 8. Pb/Cb Return 9. Cam. Mic. X 10. Cam. Mic. Y 11. Cam. Mic. shield 12. - 13. - 14. - 15. Record/Tally 16. Genlock Video/BB return 17. Cable shield (Camera GND to VTR GND) 18. Playback video / Ext. VF 19. Playback video return / Ext. VF return 20. - 21. Genlock Video/BB 22. - 23. RXD, control 24. TXD, control 26-pin female; panel view Panel part number: T1001017 A.+ Battery from VTR (+10.7 to +17V) B.- Battery Ground 1. SDI 2. SDI Return 3. Y Return 4. Y