Text of the manual

Employer must enforce compliance

with the safety warnings and all other instructions which accompany this tool as shipped from the manufacturer. Keep this manual available for use by all people assigned to the use of this tool. For personal safety and proper operation of this tool, read and understand all of these instructions carefully. 2 tablE oF CoNtENtS Employer’s Responsibilities ....................... 2 Safety Warnings ........................................ 3 Tool Use .................................................... 7 Maintenance .............................................. 9 Troubleshooting ....................................... 10 Accessories ............................................. 10 Technical Specifications .......................... 11 Fastener Specifications ........................... 11 Limited Warranty ..................................... 12

y Read and understand tool labels

and manual. Failure to follow warnings could result in DEATH or SERIOUS INJURY. Save these instructions y y Use safety equipment. Always wear ANSI Z87.1 safety glasses with permanently attached side shields. Dust mask, non-skid safety shoes, hard hat, or hear- ing protection must be used for appropriate conditions. Failure to do so could result in personal injury. RX Personal Safety y y Stay alert, watch what you are doing, and use common sense when operating a power tool. Do not use tool while tired or under the influence of drugs, alco- hol, or medication. A moment of inattention while operating power tools may result in serious personal injury. Explosion Hazard y y Never use tool in an explosive atmosphere or in the presence of combustible materials such as flammable liquids, gases or dust. y y Never use oxygen, carbon dioxide or any other bottled gas as a power source for this tool; the tool will explode and cause serious injury. y y Always remove finger from trig- ger when not driving fasteners. Never carry the tool with finger on or under trigger. y y uSE CautioN as these tools will drive a fastener when the trigger is pulled. y y Always assume the tool con- tains fasteners. No horseplay. Respect the tool as a working implement. y y Keep tool pointed away from yourself and others and connect air to tool. y y Tools shall be operated at the lowest pressure needed for the application. This will reduce noise levels, part wear, and energy use. 3

y Drive fasteners into work surface

only; never into materials too hard to penetrate. y y Do not drive fasteners on top of other fasteners or with the tool at too steep of an angle; the fasteners can ricochet and hurt someone. y y Do not drive fasteners close to the edge of the work surface. The workpiece is likely to split and the fastener could fly free or ricochet and hit someone. y y Tool may eject a fastener when connected to air supply; there- fore, remove all fasteners from tool before connecting air. y y Never use tool if trigger or springs have become inopera- ble, missing or damaged. Do not tamper with or remove trigger or springs. y y Disconnect tool from air before doing tool maintenance, clearing a jammed fastener, leaving work area, moving tool to another location, or handing the tool to another person. 4

y Make sure all screws and caps

are securely tightened at all times. Make daily inspections for free movement of trigger. Never use the tool if parts are missing or damaged. y y Never use a tool that leaks air or needs repair. ® y y Use only parts, fasteners, and accessories recommended or sold by SENCO. Do not modify tool without authorization from SENCO. y y Use only clean, dry, regulated compressed air at recommended pressure. 200 psig 13.7 bar y y Do not connect tools to air pres- sure that potentially exceeds 200 psig or 13.7 bar. y y Air compressors used to supply compressed air to this tool must comply with requirement ANSI/ ASME B 19.1–1995 (U.S.), “Safety Standard For Air Com- pressor Systems.” y y Air hose must have a minimum working pressure rating of 150 psig (10.3 bar) or 150% of the maximum pressure produced in the system, whichever is higher. 5

y The tool and air supply hose

must have a hose coupling such that all pressure is removed from the tool when the coupling joint is disconnected. y y Do not load fasteners with trig- ger depressed. (1) Read and understand tool labels and manual. Failure to follow warnings could result in DEATH or SERIOUS INJURY. (2) Operators and others in work area MUST wear safety glasses with side shields. (3) Keep fingers AWAY from trigger when not driving fasteners to avoid accidental firing. (4) See manual for triggering instructions. (5) NEVER point tool at yourself or others in work area. (6) NEVER use oxygen or other bottled gases. Explosion may occur. (7) MAX AIR PRESS. 120 PSI (8.3 BAR) y y Do not use tool without danger label on tool. If label is missing, damaged or unreadable, contact your SENCO representative to obtain a new label. y y Always place yourself in a firmly balanced position when using or handling the tool. y y For information on the “SENCO Safety First Program,” contact your SENCO representative. 6

y Read section titled “Safety

Warnings,” before using tool. 1 2 to load: ① Push latch. ② Slide rail open. y y Connect air supply and lay strip of staples into magazine. Use only genuine SENCO fas- teners (see Parts Chart). y y Do not load with trigger de- pressed. y y Push rail forward until it latches. 1 2 to drive fasteners: ① Position tool against work surface. ② Pull trigger. y y these tools are not required to have a workpiece contact (safety element). uSE Cau- tioN as these tools will drive a fastener when the trigger is pulled.

Should a staple jam occur:

y y Disconnect air supply. 1 2 ① Depress latch. ② Slide rail open. y y Remove staples. y y Remove jammed fastener. y y Connect air supply and lay strip of staples into magazine. Use only genuine SENCO fas- teners (see Parts Chart). y y Do not load with trigger depressed. y y Push rail forward until it latches.

automatiC toolS oNly

y y This tool is equipped with a drive rate adjustment to adjust the speed. y y Rotate the screw, not more than three turns, counter-clockwise (Q) to increase the drive rate. Rotate the screw clockwise (P), not more than three turns, to slow the drive rate. y y For single shot operation, pull trigger only partially. For auto- matic operation, pull trigger fully. maiNtENaNCE WaRNiNg y y Repairs other than those described here should be per- formed only by trained, qualified personnel. y y Read section titled “Safety Warnings” before maintaining tool. y y All screws should be kept tight. Loose screws result in unsafe operation and parts breakage. y y With tool disconnected, make daily inspection to assure free movement of trigger. Do not use tool if trigger sticks or binds. y y Squirt Senco pneumatic oil (5 to 10 drops) into the air inlet daily (depending on frequency of tool use). Other oils may damage O-rings and other tool parts. y y Wipe tool clean daily and inspect for wear. Use non-flam- mable cleaning solutions only if necessary. y y DO NOT SOAK. y y Caution: Such solutions may damage O–rings and other tool parts.

Air leak near top of tool /

Sluggish operation Solution Verify air supply / Tighten screws or install Firing System Kit Ⓐ. 2 Symptom Air leak near bottom of tool / Poor return. Solution Clean tool / tighten screws or install Piston Stop Kit Ⓑ. 3 Symptom Other problems. Solution Contact SENCO. aCCESSoRiES SENCO offers a full line of accessories for your SENCO tools, including: y y Air Compressors y y Hose y y Couplers y y Fittings y y Safety Glasses y y Pressure Gauges y y Lubricants y y Regulators y y Filters For more information or a complete illustrated catalogue of SENCO accessories, ask your representative for #MK336. Parts Kits Kit SFt10Xp / Dl / lN auto / auto-Dl Ⓐ YK0802 Ⓑ YK0803 YK0804

6S0011N, 6S0211N, 6S0311N

.030" ,76 mm .0215" ,55 mm 3/16" 5 mm A Gauge: 22 A Code A06 A08 D10 inches 3/8 1/2 5/8 mm 10 13 16 Gauge: 22 1/2" 13 mm .030" ,76 mm .0215" ,55 mm A A Code B06 B08 inches 3/8 1/2 mm 10 12 6S0021N, 6S0121N, 6S0221N, 6S0321N, 6S0421N 6S0031N .030" ,76 mm .0215" ,55 mm 3/8" 10 mm A Gauge: 22 A Code C06 C07 C08 C10 inches 3/8 7/16 1/2 5/8 mm 10 11 13 16 .050" 1,3 mm .019" ,48 mm 3/16" 5 mm A Gauge: 20 A Code E06 E07 E08 E10 inches 3/8 7/16 1/2 5/8 mm 10 11 13 16 6S0041N, 6S0341N 6S0051N, 6S0251N, 6S0351N Gauge: 20 1/2" 13 mm .019" ,48 mm .050" 1,3 mm A A Code F06 F08 inches 3/8 1/2 mm 10 13 Gauge: 20 .045" 1,1 mm .023" ,58 mm 3/8" 10 mm A A Code G06 G08 G10 inches 3/8 1/2 5/8 mm 10 12 16 6S0361N Gauge: 20 .050" 1,3 mm .019" ,48 mm 7/16" 11 mm A A Code H06 inches 3/8 mm 10 tECHNiCal SpECiFiCatioNS Minimum to maximum operating pressure 65–100 psi 4,5–7 bar Air Consumption (60 cycles per minute) 1.16 scfm 33 liter Air Inlet 1/4 in. NPT 1/4 in. NPT Maximum Speed (cycles per second) 30 (Automatic) 30 (Automatic) Weight - R 2.1 lbs. 0,955 kg Weight - D/L 2.87 1,305 Weight - A 2.44 1,108 Weight - A D/L 3.20 1,451 Weight - LN 2.01 ,915 Staple Capacity 180 180 Staple Capacity - D/L 390 390 Tool size: Height 6.57 in. 167 mm Tool size: Height - LN 8.15 207 mm Tool size: Length 8.58 in. 218 mm Tool size: Length - D/L 14.80 376 mm Tool size: Width: Main Body 1.65 in. 42 mm