Senco SFT10XP Operating Instructions Manual
Text of the manual
Employer must enforce compliance
with the safety warnings and all
other instructions which accompany
this tool as shipped from the
manufacturer.
Keep this manual available for use
by all people assigned to the use of
this tool.
For personal safety and proper
operation of this tool, read and
understand all of these instructions
carefully.
2
tablE oF CoNtENtS
Employer’s Responsibilities ....................... 2
Safety Warnings ........................................ 3
Tool Use .................................................... 7
Maintenance .............................................. 9
Troubleshooting ....................................... 10
Accessories ............................................. 10
Technical Specifications .......................... 11
Fastener Specifications ........................... 11
Limited Warranty ..................................... 12
y Read and understand tool labels
and manual. Failure to follow
warnings could result in DEATH
or SERIOUS INJURY.
Save these instructions
y
y Use safety equipment. Always
wear ANSI Z87.1 safety glasses
with permanently attached side
shields. Dust mask, non-skid
safety shoes, hard hat, or hear-
ing protection must be used for
appropriate conditions. Failure
to do so could result in personal
injury.
RX
Personal Safety
y
y Stay alert, watch what you are
doing, and use common sense
when operating a power tool. Do
not use tool while tired or under
the influence of drugs, alco-
hol, or medication. A moment
of inattention while operating
power tools may result in serious
personal injury.
Explosion Hazard
y
y Never use tool in an explosive
atmosphere or in the presence
of combustible materials such as
flammable liquids, gases or dust.
y
y Never use oxygen, carbon
dioxide or any other bottled gas
as a power source for this tool;
the tool will explode and cause
serious injury.
y
y Always remove finger from trig-
ger when not driving fasteners.
Never carry the tool with finger
on or under trigger.
y
y uSE CautioN as these tools
will drive a fastener when the
trigger is pulled.
y
y Always assume the tool con-
tains fasteners. No horseplay.
Respect the tool as a working
implement.
y
y Keep tool pointed away from
yourself and others and connect
air to tool.
y
y Tools shall be operated at the
lowest pressure needed for the
application. This will reduce
noise levels, part wear, and
energy use.
3
y Drive fasteners into work surface
only; never into materials too
hard to penetrate.
y
y Do not drive fasteners on top of
other fasteners or with the tool
at too steep of an angle; the
fasteners can ricochet and hurt
someone.
y
y Do not drive fasteners close to
the edge of the work surface.
The workpiece is likely to split
and the fastener could fly free or
ricochet and hit someone.
y
y Tool may eject a fastener when
connected to air supply; there-
fore, remove all fasteners from
tool before connecting air.
y
y Never use tool if trigger or
springs have become inopera-
ble, missing or damaged. Do not
tamper with or remove trigger or
springs.
y
y Disconnect tool from air before
doing tool maintenance, clearing
a jammed fastener, leaving work
area, moving tool to another
location, or handing the tool to
another person.
4
y Make sure all screws and caps
are securely tightened at all
times. Make daily inspections for
free movement of trigger. Never
use the tool if parts are missing
or damaged.
y
y Never use a tool that leaks air or
needs repair.
®
y
y Use only parts, fasteners, and
accessories recommended or
sold by SENCO. Do not modify
tool without authorization from
SENCO.
y
y Use only clean, dry, regulated
compressed air at recommended
pressure.
200 psig
13.7 bar
y
y Do not connect tools to air pres-
sure that potentially exceeds 200
psig or 13.7 bar.
y
y Air compressors used to supply
compressed air to this tool must
comply with requirement ANSI/
ASME B 19.1–1995 (U.S.),
“Safety Standard For Air Com-
pressor Systems.”
y
y Air hose must have a minimum
working pressure rating of 150
psig (10.3 bar) or 150% of the
maximum pressure produced in
the system, whichever is higher.
5
y The tool and air supply hose
must have a hose coupling such
that all pressure is removed from
the tool when the coupling joint
is disconnected.
y
y Do not load fasteners with trig-
ger depressed.
(1) Read and understand tool labels and manual. Failure to follow
warnings could result in DEATH or SERIOUS INJURY. (2) Operators and
others in work area MUST wear safety glasses with side shields. (3) Keep fingers AWAY from trigger
when not driving fasteners to avoid accidental firing. (4) See manual for triggering instructions.
(5) NEVER point tool at yourself or others in work area. (6) NEVER use oxygen or other bottled gases. Explosion may occur.
(7) MAX AIR PRESS. 120 PSI (8.3 BAR)
y
y Do not use tool without danger
label on tool. If label is missing,
damaged or unreadable, contact
your SENCO representative to
obtain a new label.
y
y Always place yourself in a firmly
balanced position when using or
handling the tool.
y
y For information on the “SENCO
Safety First Program,” contact
your SENCO representative.
6
y Read section titled “Safety
Warnings,” before using tool.
1
2
to load:
① Push latch.
② Slide rail open.
y
y Connect air supply and lay strip
of staples into magazine.
Use only genuine SENCO fas-
teners (see Parts Chart).
y
y Do not load with trigger de-
pressed.
y
y Push rail forward until it latches.
1
2
to drive fasteners:
① Position tool against work
surface.
② Pull trigger.
y
y these tools are not required
to have a workpiece contact
(safety element). uSE Cau-
tioN as these tools will drive
a fastener when the trigger is
pulled.
Should a staple jam occur:
y
y Disconnect air supply.
1
2
① Depress latch.
② Slide rail open.
y
y Remove staples.
y
y Remove jammed fastener.
y
y Connect air supply and lay strip
of staples into magazine.
Use only genuine SENCO fas-
teners (see Parts Chart).
y
y Do not load with trigger
depressed.
y
y Push rail forward until it latches.
automatiC toolS oNly
y
y This tool is equipped with a drive
rate adjustment to adjust the
speed.
y
y Rotate the screw, not more than
three turns, counter-clockwise
(Q) to increase the drive rate.
Rotate the screw clockwise (P),
not more than three turns, to
slow the drive rate.
y
y For single shot operation, pull
trigger only partially. For auto-
matic operation, pull trigger fully.
maiNtENaNCE
WaRNiNg
y
y Repairs other than those
described here should be per-
formed only by trained,
qualified personnel.
y
y Read section titled “Safety
Warnings” before maintaining
tool.
y
y All screws should be kept tight.
Loose screws result in unsafe
operation and parts breakage.
y
y With tool disconnected, make
daily inspection to assure free
movement of trigger. Do not use
tool if trigger sticks or binds.
y
y Squirt Senco pneumatic oil (5 to
10 drops) into the air inlet daily
(depending on frequency of tool
use). Other oils may damage
O-rings and other tool parts.
y
y Wipe tool clean daily and
inspect for wear. Use non-flam-
mable cleaning solutions only if
necessary.
y
y DO NOT SOAK.
y
y Caution: Such solutions may
damage O–rings and other tool
parts.
Air leak near top of tool /
Sluggish operation
Solution
Verify air supply /
Tighten screws or install Firing
System Kit Ⓐ.
2
Symptom
Air leak near bottom of tool /
Poor return.
Solution
Clean tool / tighten screws or install
Piston Stop Kit Ⓑ.
3
Symptom
Other problems.
Solution
Contact SENCO.
aCCESSoRiES
SENCO offers a full line of
accessories for your SENCO tools,
including:
y
y Air Compressors
y
y Hose
y
y Couplers
y
y Fittings
y
y Safety Glasses
y
y Pressure Gauges
y
y Lubricants
y
y Regulators
y
y Filters
For more information or a complete
illustrated catalogue of SENCO
accessories, ask your representative
for #MK336.
Parts Kits
Kit
SFt10Xp / Dl / lN
auto / auto-Dl
Ⓐ
YK0802
Ⓑ
YK0803
YK0804
6S0011N, 6S0211N, 6S0311N
.030"
,76 mm
.0215"
,55 mm
3/16"
5 mm
A
Gauge: 22
A
Code
A06
A08
D10
inches
3/8
1/2
5/8
mm
10
13
16
Gauge: 22
1/2"
13 mm
.030"
,76 mm
.0215"
,55 mm
A
A
Code
B06
B08
inches
3/8
1/2
mm
10
12
6S0021N, 6S0121N, 6S0221N,
6S0321N, 6S0421N
6S0031N
.030"
,76 mm
.0215"
,55 mm
3/8"
10 mm
A
Gauge: 22
A
Code
C06
C07
C08
C10
inches
3/8
7/16
1/2
5/8
mm
10
11
13
16
.050"
1,3 mm
.019"
,48 mm
3/16"
5 mm
A
Gauge: 20
A
Code
E06
E07
E08
E10
inches
3/8
7/16
1/2
5/8
mm
10
11
13
16
6S0041N, 6S0341N
6S0051N, 6S0251N, 6S0351N
Gauge: 20
1/2"
13 mm
.019"
,48 mm
.050"
1,3 mm
A
A
Code
F06
F08
inches
3/8
1/2
mm
10
13
Gauge: 20
.045"
1,1 mm
.023"
,58 mm
3/8"
10 mm
A
A
Code
G06
G08
G10
inches
3/8
1/2
5/8
mm
10
12
16
6S0361N
Gauge: 20
.050"
1,3 mm
.019"
,48 mm
7/16"
11 mm
A
A
Code
H06
inches
3/8
mm
10
tECHNiCal SpECiFiCatioNS
Minimum to maximum operating pressure
65–100 psi
4,5–7 bar
Air Consumption (60 cycles per minute)
1.16 scfm
33 liter
Air Inlet
1/4 in. NPT
1/4 in. NPT
Maximum Speed (cycles per second)
30 (Automatic)
30 (Automatic)
Weight - R
2.1 lbs.
0,955 kg
Weight - D/L
2.87
1,305
Weight - A
2.44
1,108
Weight - A D/L
3.20
1,451
Weight - LN
2.01
,915
Staple Capacity
180
180
Staple Capacity - D/L
390
390
Tool size: Height
6.57 in.
167 mm
Tool size: Height - LN
8.15
207 mm
Tool size: Length
8.58 in.
218 mm
Tool size: Length - D/L
14.80
376 mm
Tool size: Width: Main Body
1.65 in.
42 mm