Altinex MT107-304 Operation & User’s Manual

Text of the manual

MANUAL PART NUMBER: 400-0397-001

8 OUTPUTS, FIBER OPTIC FOR MULTI-TASKER™ MATRIX SWITCHER USER’S GUIDE MT107-304

TABLE OF CONTENTS

Page PRECAUTIONS / SAFETY WARNINGS ..............2 GENERAL..........................................................2 INSTALLATION .................................................2 CLEANING.........................................................2 FCC / CE NOTICE..............................................2 ABOUT YOUR MT107-304...................................3 TECHNICAL SPECIFICATIONS...........................3 PRODUCT DESCRIPTION ..................................4 APPLICATION DIAGRAM ....................................5 DIAGRAM 1: TYPICAL CONFIGURATION ........5 DIAGRAM 2 INTERNAL VIEW ..........................6 INSTALLING YOUR MT107-304 ..........................7 OPERATION ........................................................7 RS-232 CONTROL.............................................7 DESCRIPTION OF COMMANDS .......................7 TROUBLESHOOTING GUIDE .............................7 NO OUTPUT......................................................7 ALTINEX POLICY ................................................8 LIMITED WARRANTY/RETURN POLICY ..........8 CONTACT INFORMATION................................8

PRECAUTIONS / SAFETY WARNINGS

1 Please read this manual carefully before using your MT107-304. Keep this manual handy for future reference. These safety instructions are to ensure the long life of your MT107-304 and to prevent fire and shock hazard. Please read them carefully and heed all warnings. 1.1 GENERAL • Qualified ALTINEX service personnel, or their authorized representatives must perform all service. 1.2 INSTALLATION • To prevent fire or shock, do not expose this unit to rain or moisture. Do not place the MT107-304 in direct sunlight, near heaters or heat radiating appliances, or near any liquid. Exposure to direct sunlight, smoke, or steam can harm internal components. • Handle the MT107-304 carefully. Dropping or jarring can damage the card. • Do not pull the cables that are attached to the MT107-304. • Insert the card carefully into the slots of the Multi-Tasker™ without bending any edges. 1.3 CLEANING • Clean only the connector area with a dry cloth. Never use strong detergents or solvents, such as alcohol or thinner. Do not use a wet cloth or water to clean the card. Do not clean or touch any component or PCB. 1.4 FCC / CE NOTICE • This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. • This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. • Any changes or modifications to the unit not expressly approved by ALTINEX, Inc. could void the user’s authority to operate the equipment.

ABOUT YOUR MT107-304

2 MT107-304 8 OUTPUTS, FIBER OPTIC OUTPUT CARD The MT107-304 is an 8 Fiber Optic Output expansion card for use with the MT107-104 64X64 Matrix Engine. The MT107-304 outputs are compatible with Altinex DA1934KM Receiver. Each MT107-304 connects to the Output Connector on the MT107-104 Matrix Engine. Up to 8 MT107-304's may be connected to the Engine. Each card is connected with the Engine via specially provided, high bandwidth cables. The output signals are driven by high speed, fiber optic transmitters. Each transmitter is designed to drive any of four popular fiber sizes. Altinex's software and hardware allow for the switching of any input to output combination and prevents illegal switching combinations that may damage components. TECHNICAL SPECIFICATIONS 3 FEATURES/ DESCRIPTION MT107-304 GENERAL Outputs 8 Output Connectors 8 ST Fiber Optic Transmitter Compatibility Signal types Keyboard and Mouse Serial Data Signal resolution 5Mbaud Table 1. MT107-304 General MECHANICAL MT107-304 Enclosure Slots Required 1 Slot per Card Weight 0.4 lb (0.2 kg) Connector Panel Black Anodized T° Operating 10°C-50°C T° Maximum 75°C Humidity 90% non-condensing MTBF (calc.) 38,000 hrs Table 2. MT107-304 Mechanical ELECTRICAL MT107-304 Output Fiber Optic Transmitter Compatible Fibers 62.5/125um Input Input from Matrix Engine TTL Levels Maximum Rate 5MBaud (5mb/s) Table 3. MT107-304 Electrical

DIAGRAM 2 INTERNAL VIEW

MT107-304, 8 FIBER OPTIC OUTPUTS IN8 IN7 IN6 IN1 IN2 IN3 IN4 IN5 OUTPUT 40P IDC POWER PRESENT OUT8 OUT7 OUT6 OUT3 OUT4 OUT5 OUT2 OUT1 FIBER OPTIC

INSTALLING YOUR MT107-304

6 Step 1. Locate the Matrix Engine, MT107-104 or MT107-100, currently installed in the Multi-Tasker™. Ensure there are enough empty slots in the enclosure to allow for the one or more MT107-304's to be installed. Step 2. Route the ribbon cables through the notch in the add-on boards and connect to the Engine base assembly using the special high bandwidth cables provided. Make sure that the cable connector is secured in the socket of the input connector card. Step 3. Carefully, slide the MT107-304 into a slot in the Multi-Tasker™ Enclosure. Step 4. Secure each card by tightening the retainer screws at the top and bottom of each card. Step 5. Connect the output of the DA1935KM transmitter to one of the inputs on the MT107-204. Step 6. Connect the output of the MT107-304 to one of the inputs on the DA1934KM Receiver. Step 7. Using MTSetup or other RS-232 communication software, send commands to the Engine to connect the new output to the desired input. OPERATION 7 7.1 RS-232 CONTROL The MT107-304 has many advanced remote control capabilities when used in the Multi-Tasker™ Enclosure as part of an MT107-104 Matrix Switcher. These capabilities are accessible through standard RS-232 communication. The actual controlling can be accomplished through a computer control system or any other device capable of sending RS-232 commands. 7.2 DESCRIPTION OF COMMANDS Please, see the MT107-104 User's Guide for a full listing of commands available for the MT107-304 as part of a Multi-Tasker™ Matrix Switcher. TROUBLESHOOTING GUIDE 8 We have carefully tested and have found no problems in the supplied MT107-304. However, we would like to offer suggestions for the following: 8.1 NO OUTPUT Cause 1: The source has a problem. Solution: Check the source by connecting the keyboard and mouse directly to the computer and verifying they work correctly. If they are functioning, see Solution 2. Solution 2: Verify the MT107-204 is connected to the MT107-100/104 and that the cable is in good condition. If there is no signal, please, call Altinex at (714) 990-2300.

Cause 3: The path is not selected.

Solution: Make sure the input to output path is correctly selected. For example, Input 17 is connected to Output 1 in the matrix engine. Physically, the source signal should be connected to Input 17 and the receiving cable should be connected to Output 1. See RS-232 accessible commands in Section 7 of the MT107-100/104's User Guide for command details. If the devices still fail to function properly, see Cause 4. Cause 4: Cable connections are incorrect. Solution: Make sure that cables are properly connected. Also, make sure that the continuity and wiring are good. If the are still not functioning, see Cause 5. Cause 5: The transmitting or receiving device has a problem. Solution: Make sure the receiving DA1934KM and Transmitting DA1935KM have power and are properly connected. If there is still no response, please call Altinex at (714) 990-2300. ALTINEX POLICY 9 9.1 LIMITED WARRANTY/RETURN POLICY Please see the Altinex website at www.altinex.com for details on warranty and return policy. 9.2 CONTACT INFORMATION ALTINEX, INC 592 Apollo street Brea, CA 92821 USA TEL: 714 990-2300 TOLL FREE: 1-800-ALTINEX WEB: www.altinex.com E-MAIL: [email protected]

Other Matrix Switcher Manuals