Simco minion2 Operation & Maintenance Instructions

Text of the manual

Ionizing Air Blower

US Patents: 5,008,594, 6,717,792 B2, 6,785,114, 7,054,130 SIMCO's minION2 ionizing air blower is designed to control electrostatic charges in semiconductor and electronics manufacturing equipment and for benchtop applications requiring high performance in a small pack- age. Using steady-state DC corona ion technology, the minION2 fea- tures self-monitoring to ensure controlled, consistent ion output. SECTION 1 Description SECTION 2 Safety SECTION 3 Features SECTION 4 Specifications SECTION 5 Installation SECTION 6 Operation SECTION 7 Maintenance SECTION 8 Replacement Parts SECTION 9 Warranty 2257 North Penn Road Hatfield, PA 19440 (215) 997-0590 (800) 538-0750 Fax: (215) 997-3450 Publication 5200964 (Rev B, February 2007) 2257 North Penn Road Hatfield, PA 19440 Phone: (215) 997-0590 (800) 538-0750 Fax: (215) 997-3450 http://www.simcoION.biz e-mail: [email protected] ® ®

SECTION 1 Description

SIMCO’s minION2 ionizing air blower is designed to control electrostatic charges in semiconductor and electronics manufacturing equipment and for benchtop applications requiring high performance in a compact package. The minION2’s small size also makes it easily portable for field service applications where static control is necessary. Using steady state DC corona ion technology, the minION2 features self-moni- toring to ensure controlled, consistent ion output. Performance is enhanced by SIMCO’s patented radial emitter array and ion balance maintained with the patented ionizing circuitry. Structured airflow from the patented air outlet ensures maximum delivery of ionized air to the target. These features in the design of the minION2 enable it to meet the demands of critical semiconductor equipment manufacturers with corona ionization. The minION2 uses modular wiring to enable “daisy chaining” of units, up to three units may be daisy chained on a standard power supply. A plug-type ter- minal block is included for easy wiring if the user desires to hard-wire the unit in place. There is the option of supplying power to the unit through the terminal block where the user wishes to supply power from a 24 VDC machine bus. The terminal block also features relay contact output of the unit’s fault alarm for remote fault sensing. An optional clamp-on spring arm stand is available for benchtop applications requiring elevated positioning, or for locations with a restricted mounting surface area. SECTION 2 Safety CAUTION! 1. Read the complete Operation Manual before operating. Failure to follow instructions may result in damage to the ionizer and/or personal injury. 2. The AC adapter is supplied with a 2- or 3-prong inlet plug, which must be inserted into an appropriate, properly wired wall outlet. 3. A factory-qualified service technician must perform component service and repairs. Please contact SIMCO Customer Service for information. WARNING! 4. Keep the unit dry. Do not operate the unit in flammable or explosive atmospheres. 5. Do not insert objects through the unit's intake or outlet grilles while in operation. Damage to the ionizer and/or personal injury may result. SECTION 9 Warranty SIMCO warrants its products to be free of defects in components, workmanship, or materials for a period of one year from date of purchase. This warranty does not apply to any physical or electrical damage caused by misuse, abuse or negli- gence (such as any modifications made to the unit or service work done by any other than SIMCO authorized technicians). Any unit with altered or removed serial number is ineligible for warranty. SIMCO will not be liable for loss or damage due directly or indirectly to an occurrence or use for which the product is not designed or intended. In no event shall SIMCO be liable for incidental or consequential damages except where state or regional laws override. This warranty extends to the original purchaser and is not transferable. No per- son, agent, distributor, dealer or company is authorized to change, modify, or amend the terms of this warranty in any manner whatsoever. All products returned must have an “RA” (Return Authorization) number regard- less of warranty status. Call SIMCO for an assigned RA number. Information in this document is subject to change without notice and does not represent a commitment on the part of SIMCO. No part of this manual may be reproduced or transmitted in any form or by any means, electronic or mechani- cal, including photocopying and recording, for any purpose other than the pur- chaser’s personal use without written permission of SIMCO. 2 9

SECTION 8 Replacement Parts/Part Numbers

Part Number Description 4011424 minION2 (no power supply) 4011425 minION2 (with 100/120VAC Japan / North America power supply) 4011426 minION2 (with 230VAC Continental Europe power supply) 4011427 minION2 (with 230VAC United Kingdom power supply) 5051406 minION2 power supply only (100/120VAC Japan / North America) 5051407 minION2 power supply only (230VAC Continental Europe) 5051408 minION2 power supply only (230VAC United Kingdom) 4371099 emitter, standard stainless steel (6 required) 4370760 emitter, long life tungsten (6 required) 4520764 modular cable, 4P4C, 3’ long 4520767 modular cable, 4P4C, 6’ long 5051141 articulated arm kit SECTION 3 Features • Small and compact • Closed –loop balance control • Simple to install and operate SECTION 4 Specifications OPERATING SPECIFICATIONS (Balance) Offset Voltage: 0+/-10 V Discharge time in seconds: Distance 305 mm 460 mm 610 mm 760 mm 915 mm (12 in.) (18 in.) (24 in.) (30 in.) (36 in.) Fan - High 2 sec. 3 sec. 5 sec. 7 sec. 9 sec. Fan - Low 3 sec. 4 sec. 7 sec. 9 sec. 12 sec. Offset voltage and discharge time determined as per ANSI/ESD STM3.1 using 6” x 6”, 20 pF plate (charged plate monitor). Discharge times are in seconds from 1000 volts to 100 volts. Input Power: 24 VDC, 250 mA, 6W Power Supply: Universal 100-240 Vac input (IEC320) / 24 Vdc, 750 mA output, suitable to power up to 3 units. Operating Temperature: 0˚C to 50˚C (32˚F - 122˚F) Airflow Volume: Fan - High: 42 CFM (1.2 m3/min) Fan – Low: 21 CFM (0.6 m3/min) Audible Noise: 52 dB(A) at 610mm (24 in.) 48 dB(A) at 1m (39 in.) High fan speed, measured perpendicular to air outlet. ON/OFF: Switch Fan Speed: Variable, recessed adjustment. Indicators: Power: green LED, Fault: red LED. Connectors: Two 4-position, 4-contact (4P4C) modular “handset” connectors for power, may also be used for daisy chaining units. Modular cable is included with unit. Modular connector part numbers: (Amp 5-641334-3, Hirose TM3P-44P, Kobiconn, 154-UL6164) 3 8

Plug type terminal block may be used for power

and/or faultoutput connection. Terminal block is included with unit. Terminal block part numbers: (Weidmuller 1792890000, Phoenix 1803604, Altech 36.305) MECHANICAL SPECIFICATIONS Emitter Material: Polished stainless steel Enclosure Material: Reinforced polycarbonate, color: white Enclosure Dimensions: (98mm W x 136mm H x 60mm D) 3 7/8” W x 5 3/8” H x 2 3/8” D Unit Weight: (0.5 kg) 1.1 lb Stand Material: Nickel plated stainless steel SECTION 5 Installation 5.1 Unpacking Carefully remove the equipment from the carton and inspect the contents. NOTE: If any damage has occurred during shipment, notify the local carri- er at once. A report should also be forwarded to SIMCO, 2257 North Penn Road, Hatfield PA 19440. See Section 9 (Warranty) for Return Shipment information. 5.2 Installing The minION2 ionizer is designed for portable or permanent operation. Typically, the unit should be positioned such that there is good airflow provided to the crit- ical area. Generally this requires that the unit be within 36” inches of the intend- ed target. The stand provided can be used in a permanent operation by bolting it to a sturdy flat surface such as a wall or shelf. The unit can be mounted hori- zontally if required. CAUTION! 5.3 Electrical Connections The standard AC adapter provided with the minION2 is a universal input AC type adapter with a line cord suitable for the region of operation. This AC adapter may be used to power up to three minION2 ionized air blowers by wiring them in series (daisy chain fashion) with the modular cords included. The con- nectors used on the minION2 are 4P4C modular “handset” style connectors. For reference, the modular cable carries +24 VDC on the inner two conductors and 7.3 Ion Output and Balance Check To test the unit for ion output, the use of a charged plate monitor is recommend- ed. Prior to performing these checks, clean the emitters as described above and allow the unit to run for 10 minutes to allow the ion balance to stabilize. Offset voltage and discharge times can be measured and checked against the Ion Balance and Ion Output tables in Section 4, Specifications. If a charged plate monitor is not available, periodic verification instrumentation may be used but if periodic verification instruments are used it will be necessary to get “baseline” data using the chosen periodic verification instrument. 7.4 Emitter Replacement To replace emitters, turn off the minION2 and unplug it from the power supply at the rear panel connector. Lay unit face down on a soft surface. Remove the four Philips head screws at the air inlet on the rear panel. Lift the rear panel out of the enclosure and set to one side (Note how the black plastic divider fits between the ionizer and circuit boards during disassembly). The ionizing hub contains sockets for the ion emitting pins. Carefully remove the ion emitters by pulling them straight out from the ionizer hub. Push new ion emitters into the sockets, make sure all sockets have emitters and all emitters are fully inserted into their sockets. Replace the rear panel on the enclosure while guiding the black plastic divider back into place. Ensure that the power switch and power jacks are properly fitted through the openings on the rear panel. Secure the rear panel with the four Philips head screws, do not over tighten the screws. Test unit and return to service. 7.5 Troubleshooting / Diagnostics This information provides a quick troubleshooting reference for the minION2 ionizing air blower. Should any of these possible solutions not solve the problem, contact SIMCO. 4 7 PROBLEM CAUSE SOLUTION UNIT FAILS TO OPERATE AC ADAPTER NOT CONNECTED CHECK ALL ELECTRICAL (NO GREEN INDICATOR CONNECTIONS LIGHT) FAULTY AC ADAPTER REPLACE AC ADAPTER UNIT FAILS TO OPERATE INTERNAL FAULT RETURN UNIT FOR REPAIR (GREEN INDICATOR LIGHT ON) RED FAULT INDICATOR DIRTY EMITTER HUB CLEAN EMITTER HUB AS ILLUMINATES DESCRIBED ABOVE INTERNAL HV FAULT RETURN UNIT FOR REPAIR EXCESSIVELY LONG DIRTY EMITTERS CLEAN EMITTERS AS STATIC DISCHARGE TIMES DESCRIBED ABOVE WORN EMITTERS REPLACE ION EMITTERS ION BALANCE OUT OF DIRTY EMITTERS CLEAN EMITTERS AS SPECIFICATION DESCRIBED ABOVE WORN EMITTERS REPLACE ION EMITTERS GROUNDED METAL NEAR MOVE METAL AWAY FROM IONIZED AIR OUTLET OUTLET OR MOVE OUTLET AWAY FROM METAL

ground/return is on the outer two conductors.

The minION2 may also be powered through the plug type terminal block locat- ed on the rear panel; +24 VDC goes to pin 1 and the ground/return goes to pin 2. This allows powering of minION2 ionized air blowers from a 24 volt machine bus. Each minION2 draws 250 milliamps so adequate current must be provided. A unit powered through the plug type terminal block may power other minION2 units wired in series (daisy chain fashion) with the 4P4C modular cords includ- ed. Power distributed through the modular cable must be limited to a maximum of 2 amps for safety purposes. Wired in this fashion, the recommended maxi- mum number of units wired in series is 5. The plug type terminal block also provides relay contact output for the fault alarm. Pin 4 is Common. Pin 5 is Normally Open. Pin 3 is Normally Closed. The relay contacts are rated for a maximum of 1 A at 30 Vdc resistive with a maximum switching voltage of 220 VDC. A terminal block plug is supplied with the minION2. SECTION 6 Operation The minION2 power switch is located on the rear panel of the unit, above the modular cable jacks. The rear panel also has a small hole next to the modular cable jacks that provides access to the recessed fan speed control adjustment. The fan speed may be adjusted with a small screwdriver or trim pot tool. Clockwise rotation provides maximum fan speed, counterclockwise provides minimum fan speed. The front panel of the minION2 has two LED indicator lights. The green LED indicates the unit is powered. The red LED is a fault indicator for the high volt- age power supply monitoring circuit. The high voltage power supply monitor- ing circuit also drives the fault alarm relay. The minION2 produces an ionized air stream that covers a targeted area. The time required to neutralize a static charge on an item in the target area depends on several factors. Two important factors are; distance to ionizer and air veloci- ty. Set the fan speed as high as acceptable to provide more rapid static neutral- ization. For fast neutralizing, the minION2 should be as close to the target area as practical. SECTION 7 Maintenance 7.1 Emitter Cleaning To clean emitters, turn off the minION2 and unplug it from the power supply. Visually inspect the emitter array for particle or dust accumulation. Moisten a lint free swab with deionized water or isopropyl alcohol and insert it through the inlet grille. Wipe each emitter clean and clean the emitter hub as necessary to remove accumulation. Allow to evaporate completely before returning the minION2 to service. 7.2 Air Inlet and Outlet Cleaning The air inlet grille on the rear of the unit and the ionized air outlet should remain clean to prevent restriction of air flow. They can be cleaned with a soft brush or vacuum. 5 6

Other Blower Manuals