LB-Hex User Manual Rev. B

© 2017 Blizzard Lighting, LLC TABLE OF CONTENTS LB Hex™ 1 1. Getting Started 3 What’s In The Box? 3 Getting It Out Of The Box 3 Powering Up! 3 Getting A Hold Of Us 3 Safety Instructions (Don’t Stick Your Hand In The Toaster!) 4 2. Meet The LB Hex™ 3 Features 5 DMX Quick Reference 5 The LB Hex™ Pin-up Picture 6 3. Setup 7 Fuse Replacement 7 Connecting A Bunch Of LB Hex™ Fixtures 7 Data/DMX Cables 7 Cable Connectors 8 3-Pin??? 5-Pin??? Huh? 8 Take It To The Next Level: Setting up DMX Control 8 Fixture Linking (Master/Slave Mode) 9 Mounting/Rigging 9 � Using�this�fixture�with�the�wiCICLE®�Wireless�DMX�System� ���������10 4. Operating Adjustments 12 Navigating The Control Panel 12 Control Panel Menu Structure 13 DMX Mode 13 Master/Slave Mode 13 Built-in Programs & Speed Control 13 Static Colors, Strobe, & Sound Active Mode 13 Manual Color Mixing 13 � LED�Display�On/Off� � � � � ���������14 Dimming Curve & Speed Settings 14 DMX Channel Values In-Depth 14 5. Appendix 15 Keeping Your LB Hex™ As Good As New 16 Returns (Gasp!) 16 Shipping Issues 16 Tech Specs 17 Troubleshooting 17 Dimensional Drawings 18 � Internal/External�Parts� � � � � ���������19

LB-Hex User Manual Rev. B

© 2017 Blizzard Lighting, LLC 1. GETTING STARTED What’s In The Box? � •�1�x�LB�Hex™�Professional�LED�Fixture � •�An�Ever-So-Handy�Power�Cord • This Lovely User Manual Getting It Out Of The Box Congratulations�on�your�purchase�of�one�super-cool�6-in-1�LED�PAR�can!�Now�that� you’ve got your LB Hex™ (or hopefully, more!), you should carefully unpack the box and check the contents to ensure that all parts are present and in good condition. If anything looks as if it has been damaged in transit, notify the shipper immediately and keep the packing material for inspection. Again, please save the carton and all packing materials.�If�a�fixture�must�be�returned�to�the�factory,�it�is�important�that�the�fixture�be� returned in the original factory box and packing. Powering Up! All�fixtures�must�be�powered�directly�off�a�switched�circuit�and�cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0% to 100% switch. AC Voltage Switch -�Not�all�fixtures�have�a�voltage�select�switch,�so�please�verify�that� the�fixture�you�receive�is�suitable�for�your�local�power�supply.��See�the�label�on�the� fixture�or�refer�to�the�fixture’s�specifications�chart�for�more�information.��A�fixture’s� listed current rating is its average current draw under normal conditions. Check the fixture�or�device�carefully�to�make�sure�that�if�a�voltage�selection�switch�exists�that�it�is� set to the correct line voltage you will use. Warning! Verify that the voltage select switch on your unit matches the line voltage applied. Damage to your fixture may result if the line voltage applied does not match the voltage indicated on the voltage selector switch. All fixtures must be connected to circuits with a suitable Ground (Earthing). Getting A Hold Of Us If something is wrong, please just visit our website at www.blizzardlighting. com and open a support ticket. We’ll be happy to help, honest. Disclaimer:�The�information�and�specifications�contained�in�this�document�are�subject� to change without notice. Blizzard Lighting™ assumes no responsibility or liability for any errors or omissions that may appear in this user manual. Blizzard Lighting™ reserves the right to update the existing document or to create a new document to correct any errors or omissions at any time. You can download the latest version of this document from www.blizzardlighting.com. Author: Date: Last Edited: Date: J. Thomas 1/30/2015 J. Thomas 4/18/2017

LB-Hex User Manual Rev. B

© 2017 Blizzard Lighting, LLC SAFETY INSTRUCTIONS • Please keep this User Guide for future use. If you sell the unit to someone else, be sure that they also receive this User Guide. • ALWAYS make sure that you are connecting to the proper voltage, and that the line voltage you are connecting to is not higher than that stated on the de- cal�or�rear�panel�of�the�fixture. • This product is intended for indoor use only. •��To�prevent�risk�of�fire�or�shock,�do�not�expose�fixture�to�rain�or�moisture.� •��Make�sure�there�are�no�flammable�materials�close�to�the�unit�while�operating. • The unit must be installed in a location with adequate ventilation, at least 20in�(50cm)�from�adjacent�surfaces.�Be�sure�that�no�ventilation�slots�are� blocked. • ALWAYS disconnect from the power source before servicing or replacing fuse and be sure to replace with same fuse size and type. •��ALWAYS�secure�fixture�using�a�safety�chain.�NEVER�carry�the�fixture�by�its� cord. Use its carrying handles. • DO NOT operate at ambient temperatures higher than 104°F (40°C). • In the event of a serious operating problem, stop using the unit immediately. NEVER�try�to�repair�the�unit�by�yourself.�Repairs�carried�out�by�unskilled�people� can lead to damage or malfunction. Please contact the nearest authorized tech- nical assistance center. Always use the same type spare parts. •��NEVER�connect�the�device�to�a�dimmer�pack. • Make sure the power cord is never crimped or damaged. • Never disconnect the power cord by pulling or tugging on the cord. • Avoid direct eye exposure to the light source while it is on. Caution! There are no user serviceable parts inside the unit. Do not open the housing or attempt any repairs yourself. In the unlikely event your unit may require service, please contact Blizzard Lighting online at www.blizzardlighting.com/support.

LB-Hex User Manual Rev. B

© 2017 Blizzard Lighting, LLC 2. MEET THE LB-PAR HEX MAIN FEATURES ��•���12*�high�output�15-watt�6-in-1�RGBAW+UV�LEDs • User selectable 6/11 DMX channels • Full color mixing in standalone, master/slave and DMX modes • Built-in automated & sound active programs via master/slave • User selectable 8/32-bit dimming curve modes • Durable, scratch resistant composite housing ADDITIONAL FEATURES • Lightweight and compact (It kept its New Years’ resolution!) ��•���4-button�LED�control�panel�for�easy�programming ��•���Dual�bracket�for�flexibility�in�mounting ��•���Flicker-free�constant-current�LED�driver • 3-pin male input and 3-pin female output • PowerCon™ compatible AC power In/Out connectors ��•���Can�directly�power�the�wiCICLE®�wireless�system�via�DMX DMX Quick Reference (11-Channel Mode) Channel What It Does 1 Dimmer (0% <-> 100%) 2 Red Intensity (0% <-> 100%) 3 Green Intensity (0% <-> 100%) 4 Blue Intensity (0% <-> 100%) 5 Amber Intensity (0% <-> 100%) 6 White Intensity (0% <-> 100%) 7 UV Intensity (0% <-> 100%) 8 Strobe (slow <-> fast) 9 Built-In Programs 10 Speed (slow <-> fast) 11 32-bit Dimming DMX Quick Reference (6-Channel Mode) Channel What It Does 1 Red Intensity (0% <-> 100%) 2 Green Intensity (0% <-> 100%) 3 Blue Intensity (0% <-> 100%) 4 Amber Intensity (0% <-> 100%) 5 White Intensity (0% <-> 100%) 6 UV Intensity (0% <-> 100%)

LB-Hex User Manual Rev. B

© 2017 Blizzard Lighting, LLC Figure 1: The LB Hex™ Pin-Up Picture 12* 6-in-1 RGBAW+UV�LEDs Heavy-Duty Composite Housing Secure Grip Locking Knobs Figure 2: The Rear Connections Power Out DMX In DMX Out Microphone Power In Mic Sensitivity Menu Display Menu Buttons Dual Mounting Brackets

LB-Hex User Manual Rev. B

© 2017 Blizzard Lighting, LLC 3. SETUP Fuse Replacement CAUTION! The LB Hex™ utilizes a high-output switch-mode power supply with an internal fuse. Under normal operating conditions, the fuse�should�not�require�replacement.��The�fuse�is�field�replaceable,� however�it�is�an�advanced�procedure�suited�to�qualified�individuals.�� Should your LB Hex™ fuse require replacement, please contact Bliz- zard Lighting for instructions, or to return your unit for service. Connecting A Bunch of LB Hex™ Fixtures You will need a serial data link to run light shows using a DMX-512 controller�or�to�run�shows�on�two�or�more�fixtures�set�to�sync�in�mas- ter/slave operating mode. The combined number of channels required by�all�the�fixtures�on�a�serial�data�link�determines�the�number�of�fix- tures the data link can support. Fixtures on a serial data link must be daisy chained in one single line. Also,�connecting�more�than�32�fixtures�on�one�serial�data�link�without� the use of a DMX optically-isolated splitter may result in deterioration of the digital DMX signal. The maximum recommended cable-run distance is 500 meters (1640 ft).��The�maximum�recommended�number�of�fixtures�on�a�serial�data� link�is�32�fixtures. Data/DMX Cabling To�link�fixtures�together�you’ll�need�data�cables.��You�should�use�data- grade cables that can carry a high quality signal and are less prone to electromagnetic interference. For�instance,�Belden©�9841�meets�the�specifications�for�EIA�RS-485� applications. Standard microphone cables will “probably” be OK, but note that they cannot transmit DMX data as reliably over long distanc- es. In any event, the cable should have the following characteristics: 2-conductor twisted pair plus a shield Maximum capacitance between conductors – 30 pF/ft. Maximum capacitance between conductor & shield – 55 pF/ft. Maximum resistance of 20 ohms / 1000 ft. Nominal impedance 100 – 140 ohms

LB-Hex User Manual Rev. B

© 2017 Blizzard Lighting, LLC Cable Connectors Cables must have a male XLR connector on one end and a female XLR connector on the other end. (Duh!) CAUTION:�Do�not�allow�contact�between�the�common�and�the�fix- ture’s chassis ground. Grounding the common can cause a ground loop,�and�your�fixture�may�perform�erratically.�Test�cables�with�an� ohm meter to verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each other. 3-Pin??? 5-Pin??? Huh?!? If you use a controller with a 5 pin DMX output connector, you will need to use a 5 pin to 3 pin adapter. They are widely available over the internet and from specialty retailers If you’d like to build your own, the chart below details a proper cable conversion: Conductor 3-Pin Female (Output) 5-Pin Male (Input) Ground/Shield Pin 1 Pin 1 DMX Data (-) Pin 2 Pin 2 DMX Data (+) Pin 3 Pin 3 Not Used. No Connection. No Connection. Not Used. No Connection. No Connection. Take It To The Next Level: Setting Up DMX Control Step 1: Connect the male connector of the DMX cable to the female connector (output) on the controller. Step 2: Connect the female connector of the DMX�cable�to�the�first�fixture’s�male�connec- tor (input). Note: It doesn’t matter which fixture�address�is�the�first�one�connected.�� We�recommend�connecting�the�fixtures�in� terms of their proximity to the controller, rather�than�connecting�the�lowest�fixture� number�first,�and�so�on. Step 3:�Connect�other�fixtures�in�the�chain� from output to input as above. Place a DMX terminator�on�the�output�of�the�final�fixture� to ensure best communication.

LB-Hex User Manual Rev. B

© 2017 Blizzard Lighting, LLC Fixture Linking (Master/Slave Mode) 1. Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector of the�first�fixture. 2. Connect the end of the cable coming from the first�fixture�which�will�have�a�(female)�3�pin�connec- tor�to�the�input�connector�of�the�next�fixture�con- sisting of a (male) 3 pin connector. Then, proceed to connect from the output as stated above to the input�of�the�following�fixture�and�so�on. A quick note: Often, the setup for Master- Slave and Standalone operation requires that the�first�fixture�in�the� chain be initialized for this purpose via either settings in the control panel or DIP-switches. Secondarily,�the�fixtures� that follow may also re- quire a slave setting. Check the “Operating Adjustments” section in this manual for com- plete�instructions�for�this�type�of�setup�and�configuration. Mounting & Rigging This�fixture�may�be�mounted�in�any�SAFE�position�provided�there�is� enough room for ventilation. It is important never to obstruct the fan or vents pathway. Mount the fixture�using�a�suitable�“C”�or�“O”�type�clamp.��The�clamp�should�be� rated�to�hold�at�least�10x�the�fixture’s�weight�to�ensure�structural�sta- bility. Do not mount to surfaces with unknown strength, and ensure properly�“rated”�rigging�is�used�when�mounting�fixtures�overhead. Adjust�the�angle�of�the�fixture�by�loosening�both�knobs�and�tilting�the� fixture.�After�finding�the�desired�position,�retighten�both�knobs. • When selecting installation location, take into consideration lamp replacement access (if applicable) and routine maintenance. • Safety cables MUST ALWAYS be used. •��Never�mount�in�places�where�the�fixture�will�be�exposed�to�rain,� high humidity, extreme temperature changes or restricted ventilation.

LB-Hex User Manual Rev. B

© 2017 Blizzard Lighting, LLC USING THIS FIXTURE WITH THE wiCICLE® WIRELESS DMX SYSTEM In�addition�to�the�unbridled�thrill�you�already�received�the�first�time�you�plugged�in�your�fixture,�you’ll� be�delighted�to�know�that�This�fixture�also�works�seamlessly�with�our�wiCICLE® Wireless DMX system, without additional power. •�ONLY�fixtures�bearing�this�logo�are�certified�for�use�with�the�wiCICLE® without external power. • Unauthorized modification and/or using the wiCICLE® with un- approved fixtures may cause damage to the wiCICLE® or fixture. UNDER NO CIRCUMSTANCES IS BLIZZARD LIGHTING RESPON- SIBLE FOR ANY DAMAGE FROM SUCH OPERATION. • Fixtures bearing the above logo MUST only use cable and connectors which separate chassis/case ground from cable shielding. Cabling with the shield connected to the con- nector’s�case/chassis�may�cause�malfunction�and�damage�to�the�wiCICLE®�or�fixture. •�wiCICLE® transmitters have additional power requirements and therefore cannot be powered directly from�the�fixture.��You�will�need�to�utilize�the�supplied�AC/DC�adaptor�to�drive�wiCICLE® transmitters in your system. Each�wiCICLE® acts as both a transmitter and a receiver, depending on whether a DMX source is applied to the integral XLR connector. This is an extremely powerful feature of the system, however, it also requires 1 piece of due diligence, and that is the removal of extraneous DMX signals from your lighting rig�BEFORE�proceeding. SO: BEFORE DOING ANYTHING ELSE, YOU SHOULD DISABLE ANY BUILT-IN PROGRAMS IN THE FIXTURES YOU WISH TO CONNECT AND/OR SET THEM AS SLAVES PRIOR TO RETURN- ING THEM TO DMX MODE (IF APPLICABLE). Most fixtures contain a built-in automatic, sound active or custom program which is designed to operate with the fixture NOT connected to a DMX chain. Some�of�these�programs�will�automatically�run�unless�the�fixture�is�set�to�slave�mode.��These�fixtures� typically sense DMX automatically and switch to DMX mode upon receiving DMX signal (our Pucks do that!) If�you�plug�a�wiCICLE®�“receiver”�into�an�autosensing�fixture�set�as�a�“master,�“chances�are�good�that� the�wiCICLE® “receiver” will begin transmitting the master program. Most times, this is undesirable, and taking the two seconds to switch these programs off will solve a lot of ails. Got that done? Good! Then let’s proceed! 1.�Plug�the�wiCICLE®�Receiver�into�the�“DMX�IN”�connector�of�the�fixture�and�verify�it�is�receiving�power� (the STATUS LED should illuminate.) 2.�Connect�the�AC/DC�adaptor�to�the�wiCICLE® Transmitter and verify it is receiving power (the STATUS LED should illuminate.) 3. Press the RECESSED SELECTOR BUTTON on the Transmitter to select the operating channel group. (The system will store this setting for future use) The�7-Color�Status�LED�will�change�color�to�indicate�the�current�channel�group: · GROUP 1: RED · GROUP 2: GREEN · GROUP 3: YELLOW · GROUP 4: BLUE · GROUP 5: VIOLET · GROUP 6: CYAN · GROUP 7: WHITE 4. Follow the same procedure on the Receiver to select the channel group. 5. Once both the transmitter and receiver(s) are both set to the same channel group, connect the trans- mitter�to�the�DMX�controller�or�the�DMX�out�of�a�fixture�on�your�DMX�chain.�� 6.�Once�a�DMX�signal�is�provided�to�the�transmitter,�the�status�LED�will�blink�RED slowly until communi- cation�is�established�with�the�receiver.��The�status�LED�on�the��receiver(s)�will�flash�GREEN slowly until communication is established. 7.��Once�the�clearest�channel�is�auto-selected,�the�status�LEDs�will�blink�quickly�on�both�the�transmitter� and�receiver.��NOTE:��The�color�of�the�LED�DURING�operation�does�not�indicate�channel�group,�instead� it indicates whether the unit is transmitting or receiving. That’s It! NOTE: “GROUP” number also cor- responds to the “GROUP” setting on our LightCaster™ wireless DMX Transceiver.

LB-Hex User Manual Rev. B

© 2017 Blizzard Lighting, LLC 4. OPERATING ADJUSTMENTS The Control Panel All the goodies and different modes possible with the LB Hex™ are ac- cessed�by�using�the�control�panel�on�the�rear�of�the�fixture.��There�are� 4�control�buttons�below�the�LED�display�which�allow�you�to�navigate� through the various control panel menus. Is used to navigate to the previous higher-level menu item. Is�used�to�select�and�confirm/store�the�current�selection. Scrolls through menu items and numbers in ascending order. Scrolls through menu items and numbers in descending order. The�control�panel�LED�display�shows�the�menu�items�you�select�from� the menu map on page #12. When a menu function is selected, the display�will�show�immediately�the�first�available�option�for�the�selected� menu function. To select a menu item, press . Use the and buttons to navigate the menu options. Press the button to select the menu function currently dis- played, or to enable a menu option. To return to the previous option or menu without changing the value, press the button. MENU UP DOWN ENTER

LB-Hex User Manual Rev. B

© 2017 Blizzard Lighting, LLC Control Panel Menu Structure Addr 1-512 To choose the DMX address CHNL CH-1 6-channel DMX mode CH-2 11-channel DMX mode SP-- 0-99 Speed�adjustments�(0-99) Pr-- 1-13 Built-in programs (1-13) SOUN Sound active mode CoLo 0-63 Built-in colors Strb 0-20 Flash / strobe speed rL-- 000 - 255 Red intensity (0% <--> 100%) GL-- 000 - 255 Green intensity (0% <--> 100%) bL-- 000 - 255 Blue intensity (0% <--> 100%) AL-- 000 - 255 Amber intensity (0% <--> 100%) uL-- 000 - 255 White intensity (0% <--> 100%) UL-- 000 - 255 UV intensity (0% <--> 100%) LEd on-off Display menu on/off nodE 0-4 Dimming speed (fast <-->slow) TEnP Check�LED�board�temperature UErn Software version rSEt yes-no Restore factory settings DMX Mode Allows the unit to be controlled by any universal DMX controller. Set the Starting DMX Address: The�default�mode�for�the�fixture�is�DMX,�so�the�first�menu�item�that�you�can�edit�is�the�starting� DMX address. 1.) Navigate the main menu until you reach Addr, and press . 2.) Use the buttons to select a DMX channel from 001-512. 3.) Press the �button�to�confirm. Select the DMX Channel Mode: 1.) Navigate the main menu until you reach CHNL, and press . 2.) Use the buttons to select either 1-CH (6-ch) or 2-CH (11-ch) mode. 3.) Press the �button�to�confirm. Slave Mode:�Set�slave�fixtures�to�DMX�mode.�They�will�automatically�follow�the�master�fixture� (first�fixture�in�the�DMX�chain). Built-in Programs & Speed Control 1.) Navigate the main menu until you reach Pr--, and press . 2.) Use the buttons to choose any of its built-in programs from 1-13. 3.) Press the �button�to�confirm�your�choice. 4.)�You�can�then�adjust�the�speed�of�the�program.

LB-Hex User Manual Rev. B

© 2017 Blizzard Lighting, LLC Speed Settings: 1.) Navigate the main menu until you reach Sp--, and press . 2.) Then use the buttons to select a speed setting from 0-99. 3.) Press the �button�to�confirm. Static Colors, Strobe, & Sound Active Mode 1.) Navigate the main menu until you reach CoLo, and press . 2.) Use the buttons to select any of its static colors from 0-63. 3.) Press the �button�to�confirm�your�choice. 4.) You can then add a strobe effect if desired. Strobe: a.) Navigate the main menu until you reach Strb, and press . b.) Then use the buttons to select a strobe speed setting from 0-20 (fast <--> slow). c.) Press the �button�to�confirm. Sound Active: Navigate the main menu until you reach SOUN, and press . Manual Color Mixing: Mix your own custom colors using the R/G/B/A/W/UV intensity level setting. Red: 1.) Navigate the main menu until you reach rL--, and press . 2.) Use the �buttons�to�adjust�red�000-255. (0% <--> 100%). 3.) Press the �button�to�confirm. Green: 1.) Navigate the main menu until you reach GL--, and press . 2.) Use the �buttons�to�adjust�green�000-255. (0% <--> 100%). 3.) Press the �button�to�confirm. Blue: 1.) Navigate the main menu until you reach bL--, and press . 2.) Use the �buttons�to�adjust�blue�000-255. (0% <--> 100%). 3.) Press the �button�to�confirm. Amber: 1.) Navigate the main menu until you reach AL---, and press . 2.) Use the �buttons�to�adjust�white�000-255. (0% <--> 100%). 3.) Press the �button�to�confirm. White: 1.) Navigate the main menu until you reach uL---, and press . 2.) Use the �buttons�to�adjust�white�000-255. (0% <--> 100%). 3.) Press the �button�to�confirm. UV: 1.) Navigate the main menu until you reach UL---, and press . 2.) Use the �buttons�to�adjust�white�000-255. (0% <--> 100%). 3.) Press the �button�to�confirm. LED Display On/Off: You can set the LED menu display to either stay on continually, or turn off after 30 seconds of inactivity. 1.) Navigate the main menu until you reach LEd, and press . 2.) Use the buttons to highlight either on or oFF. 3.) The On setting will keep the display on continually, and oFF will turn the display off after 30s. 4.) Press the �button�to�confirm�your�choice. Dimming Speed & Curve Settings: You can manually set the fixtures dimming curve of your choice: 1.) Navigate the main menu until you reach node, and press . 2.) Use the buttons to highlight a speed from 0-4 (fast <--> slow). 3.) Press the �button�to�confirm.

LB-Hex User Manual Rev. B

© 2017 Blizzard Lighting, LLC DMX Values In-Depth (6-Channel Mode) Channel Value What It Does 1 000 <--> 255 Red Intensity (0% <--> 100%) 2 000 <--> 255 Green Intensity (0% <--> 100%) 3 000 <--> 255 Blue Intensity (0% <--> 100%) 4 000 <--> 255 Amber Intensity (0% <--> 100%) 5 000 <--> 255 White Intensity (0% <--> 100%) 6 000 <--> 255 UV Intensity (0% <--> 100%) DMX Values In-Depth (11-Channel Mode) Channel Value What It Does 1 000 <--> 255 Dimmer (0% <--> 100%) 2 000 <--> 255 Red Intensity (0% <--> 100%) 3 000 <--> 255 Green Intensity (0% <--> 100%) 4 000 <--> 255 Blue Intensity (0% <--> 100%) 5 000 <--> 255 Amber Intensity (0% <--> 100%) 6 000 <--> 255 White Intensity (0% <--> 100%) 7 000 <--> 255 UV Intensity (0% <--> 100%) 8 000 <--> 255 Strobe Strobe (Slow <--> Fast) 9 000 <--> 009 010 <--> 019 020 <--> 029 030 <--> 039 040 <--> 049 050 <--> 059 060 <--> 069 070 <--> 079 080 <--> 089 090 <--> 099 100 <--> 109 110 <--> 119 120 <--> 129 130 <--> 139 140 <--> 255 Programs, Auto, and Sound Active Dimmer Speed Program�1�(R/G/B�jump) Program 2 (R/G/B fade-in/out) Program 3 (R/G/B fade) Program�4�(R/G/B/A/W/UV�jump) Program 5 (R/G/B/A/W/UV fade-in/out) Program 6 (R/G/B/A/W/UV fade) Program�7�(7-Color�jump) Program 8 (7-color fade-in/out) Program 9 (7-color fade) Program 10 (Multicolor Jump) Program 11 (Multicolor fade-in/out) Program 12 (Multicolor fade) Auto Mode (Loop all programs) Sound Active Mode 10 000 <--> 255 Auto Program Speed Fade Speed (Slow <--> Fast) 11 000 <--> 005 006 <--> 055 056 <--> 105 106 <--> 155 156 <--> 205 206 <--> 255 32-Bit Dimmer As set in the control menu display Mode 0 = 8-bit, 256 dimming steps Mode 1 = 32-bit, 0-25% intensity range Mode 2 = 32-bit, 0-50% intensity range Mode 3 = 32-bit, 0-75% intensity range Mode 4 = 32-bit, full intensity dimming

LB-Hex User Manual Rev. B

© 2017 Blizzard Lighting, LLC 5. APPENDIX A Quick Lesson On DMX DMX (aka DMX-512) was created in 1986 by the United States Institute for Theatre Technology (USITT) as a standardized method for connecting lighting consoles to lighting dimmer�modules.�It�was�revised�in�1990�and�again�in�2000�to�allow�more�flexibility.��The� Entertainment�Services�and�Technology�Association�(ESTA)�has�since�assumed�control�over� the DMX512 standard. It has also been approved and recognized for ANSI standard clas- sification.�� DMX covers (and is an abbreviation for) Digital MultipleXed signals. It is the most common communications standard used by lighting and related stage equipment. DMX�provides�up�to�512�control�“channels”�per�data�link.�Each�of�these�channels�was�origi- nally intended to control lamp dimmer levels. You can think of it as 512 faders on a lighting console,�connected�to�512�light�bulbs.�Each�slider’s�position�is�sent�over�the�data�link�as�an� 8-bit number having a value between 0 and 255. The value 0 corresponds to the light bulb being completely off while 255 corresponds to the light bulb being fully on. DMX data is transmitted at 250,000 bits per second using the RS-485 transmission stan- dard over two wires. As with microphone cables, a grounded cable shield is used to prevent interference with other signals. There�are�five�pins�on�a�DMX�connector:�a�wire�for�ground�(cable�shield),�two�wires�for� “Primary” communication which goes from a DMX source to a DMX receiver, and two wires for a “Secondary” communication which goes from a DMX receiver back to a DMX source. Generally,�the�“Secondary”�channel�is�not�used�so�data�flows�only�from�sources�to�receiv- ers. Hence, most of us are most familiar with DMX-512 as being employer over typical 3-pin�“mic�cables,”�although�this�does�not�conform�to�the�defined�standard. DMX�is�connected�using�a�daisy-chain�configuration�where�the�source�connects�to�the�input� of�the�first�device,�the�output�of�the�first�device�connects�to�the�input�of�the�next�device,� and so on. The standard allows for up to 32 devices on a single DMX link. Each�receiving�device�typically�has�a�means�for�setting�the�“starting�channel�number”�that� it�will�respond�to.�For�example,�if�two�6-channel�fixtures�are�used,�the�first�fixture�might� be set to start at channel 1 so it would respond to DMX channels 1 through 6, and the next fixture�would�be�set�to�start�at�channel�7�so�it�would�respond�to�channels�7�through�12. The greatest strength of the DMX communications protocol is that it is very simple and robust. It involves transmitting a reset condition (indicating the start of a new “packet”), a start code, and up to 512 bytes of data. Data packets are transmitted continuously. As soon�as�one�packet�is�finished,�another�can�begin�with�no�delay�if�desired�(usually�another� follows within 1 ms). If nothing is changing (i.e. no lamp levels change) the same data will be sent out over and over again. This is a great feature of DMX -- if for some reason the data�is�not�interpreted�the�first�time�around,�it�will�be�re-sent�shortly. Not�all�512�channels�need�to�be�output�per�packet,�and�in�fact,�it�is�very�uncommon�to�find� all 512 used. The fewer channels are used, the higher the “refresh” rate. It is possible to get DMX refreshes at around 1000 times per second if only 24 channels are being trans- mitted. If all 512 channels are being transmitted, the refresh rate is around 44 times per second. In summary, since its design and evolution in the 1980’s DMX has become the standard for�lighting�control.��It�is�flexible,�robust,�and�scalable,�and�its�ability�to�control�everything� from dimmer packs to moving lights to foggers to lasers makes it an indispensable tool for any lighting designer or lighting performer.

LB-Hex User Manual Rev. B

© 2017 Blizzard Lighting, LLC Keeping Your LB Hex™ As Good As New The�fixture�you’ve�received�is�a�rugged,�tough�piece�of�pro�lighting�equip- ment, and as long as you take care of it, it will take care of you. That said, like anything, you’ll need to take care of it if you want it to operate as designed. You�should�absolutely�keep�the�fixture�clean,�especially�if�you�are�using�it�in�an� environment with a lot of dust, fog, haze, wild animals, wild teenagers or spilled drinks. Cleaning the optics routinely with a suitable glass cleaner will greatly improve the quality of light output. Keeping the fans free of dust and debris will keep the�fixture�running�cool�and�prevent�damage�from�overheating.�� In�transit,�keep�the�fixtures�in�cases.��You�wouldn’t�throw�a�prized�guitar,� drumset, or other piece of expensive gear into a gear trailer without a case, and similarly, you shouldn’t even think about doing it with your shiny new light fixtures.�� Common�sense�and�taking�care�of�your�fixtures�will�be�the�single�biggest�thing� you can do to keep them running at peak performance and let you worry about designing a great light show, putting on a great concert, or maximizing your cli- ent’s satisfaction and “wow factor.” That’s what it’s all about, after all! Returns (Gasp!) We’ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back, or sending a unit in for service. But, like any complex piece of equipment designed and built by humans, once in a while, something�doesn’t�go�as�planned.��If�you�find�yourself�with�a�fixture�that�isn’t� behaving�like�a�good�little�fixture�should,�you’ll�need�to�obtain�a�Return�Authori- zation (RA). Don’t worry, this is easy. Just go to our website and open a support ticket at www.blizzardlighting.com/support, and we’ll issue you an RA. Then, you’ll need to send the unit to us using a trackable, pre-paid freight method. We suggest using�USPS�Priority�or�UPS.��Make�sure�you�carefully�pack�the�fixture�for�transit,� and whenever possible, use the original box & packing for shipping. When�returning�your�fixture�for�service,�be�sure�to�include�the�following: � 1.)�Your�contact�information�(Name,�Address,�Phone�Number,�Email�address). 2.) The RA# issued to you 3.) A brief description of the problem/symptoms. We�will,�at�our�discretion,�repair�or�replace�the�fixture.��Please�remember�that� any shipping damage which occurs in transit to us is the customer’s responsibil- ity, so pack it well! Shipping Issues Damage incurred in shipping is the responsibility of the shipper, and must be reported to the carrier immediately upon receipt of the items. Claims must be made within seven (7) days of receipt.

LB-Hex User Manual Rev. B

© 2017 Blizzard Lighting, LLC Tech Specs! Weight & Dimensions Width 11.2 in (284 mm) Depth 4.5 inches (115.6 mm) Height 10.6 inches (269.5 cm) Weight 5 lbs (2.3 kg) Power Operating Voltage 100-240VAC, 50-60 Hertz Power Consumption 109W, .92A, PF: .98 Light Source LED 12*�15-watt�6-in-1�RGBAW+UV�LEDs Optical Beam Angle 25 degree beam Luminous Intensity Lux/m Red Green Blue Amber White UV All 1m 1,280 1,790 1,510 1,060 2,450 450 8,000 2m 410 580 480 330 750 170 2,360 Thermal Max. Operating Temp. 104 degrees F (40 degrees C) ambient Control Protocol USITT DMX-512 DMX Channels 6/11-channel Input/Output 3-pin XLR Male/Female Other Operating Modes Standalone, Master/Slave, Sound Active, Color Preset Other Information Another day, another six pointless words. Warranty 2-year limited warranty, does not cover malfunction caused by�damage�to�LEDs. Troubleshooting Symptom Solution Fixture Auto-Shut Off Check�the�fan�in�the�fixture.��If�it�is�stopped�or�moving�slower� than normal, the unit may have shut itself off due to high heat.�This�is�to�protect�the�fixture�from�overheating.� Beam is Dim Check optical system and clean excess dust/grime. No Light Output Check�to�ensure�fixture�is�operating�under�correct�mode,�IE� sound�active/auto/DMX/Etc.,�if�applicable.�� Chase Speed Too Fast/ Slow Check�to�ensure�proper�setup�of�speed�adjustment. No Power Check fuse, AC cord and circuit for malfunction. Slow Movement Verify that 220V/110V switch is in the correct position, if ap- plicable. Also check that speed channels are set appropriately. No Response to Audio Verify�that�the�fixture�is�in�“Sound�Active”�mode. If your problem persists or isn’t listed, please open a support ticket online at: www.blizzardlighting.com/support.

LB-Hex User Manual Rev. B

© 2017 Blizzard Lighting, LLC Dimensional Drawings 8.5 in (215 mm) 9.8 in (248.2 mm) 11.2 in (284 mm) 10.6 in (269.5 mm) 4.5 in (115.6 mm) DISCLAIMER: The�power�connector�fitted�to�the�fixture�and�fixture�cord�are�designed�for�compatibility� with products manufactured by Neutrik AG, Neutrik USA and their related entities, however they�are�not�manufactured�by,�affiliated�with�or�endorsed�by�Neutrik�AG,�Neutrik�USA,�or� any�related�entity.��Neutrik®�and�powerCON®�are�registered�trademarks�of�Neutrik�AG.

LB-Hex User Manual Rev. B

© 2017 Blizzard Lighting, LLC Internal/External Parts # Name # Name 1. Upper housing cover 11. PowerCon™compatible input 2. Upper lamp pressing plate 12. Red PVC 3. Under lamp pressing plate 13. PCB-DMX canon socket 4. Lamps 14. Power supply 5. Copper pillar 15. Master PCB 6. PCB-lamp board 16. Outer bracket 7. Radiator 17. Knob 8. Copper pillar 18. Rubber gasket 9. 8015 fan 19. Inner bracket 10. PowerCon™ compatible input 20. Bottom housing cover