Calrec Artemis Installation And Technical Manual
Read Online
Read the Calrec Artemis Installation And Technical Manual online using the built-in PDF viewer.
Text of the manual
Putting Sound in the Picture
ARTEMIS INSTALLATION & TECHNICAL MANUAL
Digital Broadcast Production Console
Shine - Beam - Light
Calrec Audio Ltd
Nutclough Mill
Hebden Bridge
West Yorkshire
England UK
HX7 8EZ
Tel: +44 (0)1422 842159
Fax: +44 (0)1422 845244
E-mail: [email protected]
calrec.com
No part of this manual may be reproduced
or transmitted in any form or by any means,
electronic or mechanical, including photocopying
and scanning, for any purpose, without the prior
written consent of Calrec Audio Ltd.
Whilst the Company ensures that all details in this
document are correct at the time of publication,
we reserve the right to alter specifications and
equipment without notice. Any changes we make
will be reflected in subsequent issues of this
document. The latest version will be available
upon request. This publication is for International
usage.
Calrec Audio Ltd reserve the right to change
specifications without notice. E & O.E.
The established policy of Calrec Audio
Ltd. is to seek improvements to the design,
specifications and manufacture of all products.
It is not always possible to provide notice outside
the company of the alterations that take place
continually.
Despite considerable effort to produce up to
date information, no literature published by
the company nor any other material that may
be provided should be regarded as an infallible
guide to the specifications available nor does
it constitute an offer for sale of any particular
product.
Apollo, Artemis, Summa, Alpha, Sigma, Omega,
Zeta, Hydra Audio Networking and Bluefin
High Density Signal Processing (HDSP) are
trade marks of Calrec Audio Ltd. Dolby®E is a
registered trade mark of Dolby Laboratories, Inc.
All other trade marks are acknowledged.
© 2016 Calrec Audio Ltd. All Rights Reserved.
Health and Safety
7
Technical Support
8
Control Surface
9
Surface Dimensions and Assembly
10
Desk-top mounting
10
Floor stand options
10
Bolt-down 'OB' stands
11
Reduced height stands
12
Surface sizes
12
Typical surface measurements
13
Access to surface connections
14
Access to internal surface components
14
Rear Connector Interface and Covers 14
Floor Stand Removal
15
Surface Components
16
POE (Power Over Ethernet) switch
16
POE Reset connections
18
Surface Switches
19
Surface Power - AC
20
Surface Power - DC
21
Control Surface Cat5 Cable Coding
22
System PC
23
PC power and reset
23
System network data connection
23
LAN connection
24
Keyboard and mouse
24
Touchscreen monitor
24
Accessible PC USB port
24
Operating system
24
3rd Party software
24
Serial port
24
Antivirus Protection
24
Backup PC
25
Processing Core – Beam / Shine 27
Core Dimensions and Mounting
28
Airflow
28
Acoustic Noise
28
Support
28
Connections
28
Card Types & Layout
29
Card layout
29
Reset, sync interface & fan status
29
Installing / removing cards
30
Standard Status LED's
30
Master Control processor
31
DSP
31
Router / Expander
32
Power Supply
32
Processing Core – Light
33
Core Dimensions and Mounting
34
Airflow
34
Support
34
Connections
35
Card layout
35
Installing / removing cards
35
Card types & Layout
35
Reset & sync interface card
36
Standard status LEDs
36
Control Processor Module
36
DSP
37
Router
37
Power supply
37
Pre-2015 Cores
38
Standard status LEDs
38
Obsolete Control Processor
38
Airflow
39
Support
39
Connection Information
41
SFP - Overview
42
SFP slot orientation
42
SFP latching and extraction
42
SFP slot covers
43
Loose SFP storage
43
Power Budgets & Heat Management
43
Here is a simple 5 point guide to this:-
43
Copper SFP Connectivity
44
Shielded cables and connectors
44
Maximum cable length
44
Cable routing considerations
44
Termination - strain relief
44
Termination - pin-out
45
Testing / certification
45
Temporary / reusable cables
45
Fibre SFP Connectivity
46
Singlemode vs multimode
46
Identification
46
Duplex Connectors / terminations
46
Single strand, bi-directional SFPs
46
SFP / fibre specifications
46
Testing / certification
47
Areas of loss
47
Fibre handling practise
47
Ruggedised fibre
47
Cleaning and preventative maintenance
47
Fibre - General Rules
47
WARNING
47
Cleaning fibre optic cables and connectors 48
Cleaning procedure
48
Additional notes
48
Cleaning optical transceivers
48
Cleaning procedure
48
Synchronisation
49
Sync source selection
49
Surface to Core Connection
50
4 ARTEMIS Digital Broadcast Production Console
Control Surface SideCar Connection
51
Extended Control Surface Connections 52
Audio I/O Connections
53
Audio Formats
53
Power
53
ID configuration
53
Fixed format I/O box IDs
53
Address 2
53
Modular I/O box ID setting
53
Hydra2 connection
54
GPIO Connections
56
GP inputs
56
GP outputs
56
Dry closure only outputs
56
Connecting to Other Consoles/Routers 60
Surface Rear Connector Pin-Outs
62
Moving coil meters*
62
RTW meters
63
DK meters
64
Headphone sockets
65
Loudspeaker panels
65
External Control
67
SW-P-08 Router Remote Control
68
Connection and redundancy
68
Connection configuration
68
SW-P-08 I/O mapping configuration
68
Ember Remote Control
69
Connection and redundancy
69
Connection configuration
69
Control configuration and enabling
69
Calrec Serial Control Protocol
70
CSCP versions
70
Faders controlled by CSCP
70
Controls available via CSCP
70
Connection
70
Secondary connections
71
Multiple consoles
71
Connecting via corporate LAN
71
Configuration
71
User & boot up enable / disable
71
System Status over SNMP
72
Connecting to the SNMP server
72
Configuring the SNMP Agent
72
Scope of System Status over SNMP
72
Wireless Router Configuration – Assist 73
Console Configuration
73
Wireless Router Configuration
74
DHCP Configuration
74
Other Configuration Parameters
74
Security Considerations
75
Assist Application Configuration
75
RS232/422 Conversion
76
Perle IOLAN Configuration
77
Telnet IP configuration
77
Main configuration - Web Manager
77
Setup & Configuration
81
Overview and GUI Access
82
Creating a Clean Starting Point
83
Screensaver Timeout - 'Dark-Mode'
84
Sync Setup
85
Main Application Sync
85
H20 Sync
85
I/O Configuration
86
Assigning Paths to Faders
87
Assignable faders
87
Assigning paths
87
Using Tone
88
Monitoring Output Setup
89
Speaker configuration
89
Metering Setup
90
Calrec TFT meters
90
Moving coil and third party meters
90
Monitor / Meter Source Selection
91
Input & Output Port Patching
93
Talkback and external tone
94
Assigning GPIO
95
User Control Logging Setup
96
Path Controls Logged
97
User Logs
99
Panel Options
101
Fader Panel - IC5791
102
Upstand TFT Panel - MU5794
103
Monitor Panel - MY5792
104
Monitor Panel - MW5940
105
Reset / 3rd party Meter Panel
106
3rd party meters
106
Moving coil meters
106
RTW TM7 meter types and layout
106
Audio interface for 3rd party meters
106
Hydra2 output provision
107
Resets
107
Talkback mic
107
USB port
107
Loudspeaker Panel - LS5958
108
Connections
108
Obsolete Panels
111
Mechanical Moving Coil Panels
112
Surround scopes
112
VU
112
PPM RG/RG
112
PPM RG/WO
112
DIP switch configuration
113
Level
113
L/R or M/S
113
Resets
113
Talkback mic
113
USB port
113
Specifications
115
General Specifications - Shine/Beam/
Light
116
Power/Environmental Specification
117
Audio Performance Specification
121
6 ARTEMIS Digital Broadcast Production Console
Information
IMPORTANT INFORMATION
After Sales Modifications
Please be aware that any modifications
other than those made or approved by
Calrec Audio Limited or their agents, may
invalidate the console’s warranty. This
includes changes to cabling provided by
Calrec and variations to the recommended
installation as detailed in Calrec
documentation.
Modifications to this equipment by any
party other than Calrec Audio Limited
may invalidate EMC and safety features
designed into this equipment. Calrec
Audio Limited can not be liable for any
legal proceedings or problems that may
arise relating to such modifications.
If in doubt, please contact Calrec Audio
Limited for guidance prior to commencing
any modification work.
Installation
In many installations the AC power
connectors will not be readily accessible,
effectively making the equipment
permanently connected. The installation
should be carried out in accordance
with all applicable installation rules and
regulations.
Service Personnel
The AC power disconnect devices are
the 2 x IEC (IEC60320-1 C13/C14)
couplers located at the rear of each unit.
WARNING: The apparatus has a dual
power system. It is essential that BOTH
AC power IEC couplers are disconnected
to prevent exposure to hazardous voltage
within the unit.
Third Party Equipment
Integrating third party equipment into
a Calrec system may compromise the
product's ability to comply with the
radiated emission limits set in the EMC
(Electro Magnetic Compatibility) standard
EN55022.
Calrec Audio Limited can not be
responsible for any non-conformities
due to use of third party equipment. If
in doubt, please contact Calrec Audio
Limited for guidance prior to integrating
any third party equipment.
ESD (Static) Handling Procedures
In its completed form, this equipment has
been designed to have a high level of
immunity to static discharges. However,
when handling individual boards and
modules, many highly static sensitive
parts are exposed. In order to protect
these devices from damage and to protect
your warranty, please observe static
handling procedures, for example, use an
appropriately grounded anti-static wrist
band. Calrec will supply an electrostatic
cord and wrist strap with all of its digital
products.
All modules and cards should be returned
to Calrec Audio Limited in anti-static
wrapping. Calrec Audio Limited can
supply these items upon request, should
you require assistance.
This applies particularly to digital products
due to the types of devices and very
small geometries used in their fabrication,
analogue parts can however still be
affected.
RoHS Legislation
In order to comply with European RoHS
(Reduction of Hazardous Substances)
legislation, Calrec PCB and cable
assemblies are produced with lead-free
(tin/copper/silver) solder instead of tin/
lead solder. See Figure 1.
In the unlikely event of a customer
having to carry out any re-soldering on
Apollo, Artemis or Hydra2 hardware,
it is imperative that lead-free solder is
used; contaminating lead-free solder with
leaded solder is likely to have an adverse
effect on the long-term reliability of the
product. Circuit boards assembled with
lead-free solder can be identified (in
accordance with IPC/JEDEC standards)
by a small oval logo (see Figure 2) on the
top-side of the circuit board near the PCB
reference number (8xx-xxx). The same
logo is used on the connector hoods of
soldered cable assemblies.
If in doubt, please check with a Calrec
customer support engineer before
carrying out any form of re-soldering.
ISO 9001 and RAB Registered
Calrec Audio Ltd has been issued
the ISO9001: 2008 standard by the
Governing Board of ISOQAR.
The award, for both UKAS (Figure 3)
and RAB (Figure 4) registration, is the
most comprehensive of the ISO9000
international standards. Granted in
recognition of excellence across design,
development, manufacture and after-
sales support, the certification follows a
rigorous and thorough review of Calrec’s
internal and external communication and
business procedures.
FIGURE 1 - LEAD FREE
Pb
Pb-Free
Lead
Free
FIGURE 3 - UKAS REGISTRATION
FIGURE 4 - RAB REGISTRATION
FIGURE 2 - LEAD FREE LOGO
e1
CALREC Putting Sound in the Picture
7
HEALTH AND SAFETY
Important Safety Instructions:
• Read these instructions.
• Keep these instructions.
• Heed all warnings.
• Follow all instructions.
• Do not use this apparatus near water.
• Do not block any ventilation openings.
Install in accordance with the
manufacturer’s instructions.
• Do not install near any heat sources
such as radiators, heat registers,
stoves, or other apparatus (including
amplifiers) that produce heat.
• Protect the power cord from being
walked on or pinched particularly at
the plugs, convenience receptacles,
and the point where they exit from the
apparatus.
• Use only with the cart, stand, tripod,
bracket, or table specified by the
manufacturer, or sold with the
apparatus. When a cart is used,
use caution when moving the cart/
apparatus combination to avoid injury
from tip-over.
• Refer all servicing to qualified service
personnel. Servicing is required when
the apparatus has been damaged in
any way, such as power-supply cord
or plug is damaged, liquid has been
spilled or objects have fallen into the
apparatus, the apparatus has been
exposed to rain or moisture, does not
operator normally, or has been dropped.
• Warning: To reduce the risk of fire
or electric shock, do not expose this
apparatus to rain or moisture.
• Not intended for outdoor use.
• This equipment must be EARTHED.
• Before starting any servicing operation,
equipment must be isolated from the
AC power supply. The disconnect
devices are the 2 x IEC connectors
(IEC 60320-1 C13/C14 couplers).
• Do not allow ventilation slots to be
blocked.
• Do not leave the equipment powered
up with the dust cover fitted.
Cleaning
For cleaning the front panels of the
equipment we recommend using a soft
anti-static cloth, lightly dampened with
water if required.
Explanation of Warning Symbols
Triangular warning symbols contain a
black symbol on a yellow background,
surrounded by a black border.
The lightning flash with arrow head
symbol within an equilateral triangle, as
shown on this page, is intended to alert
the user to the presence of dangerous
voltages and energy levels within the
product’s enclosure that may be of
sufficient magnitude to constitute a risk of
electric shock or injury.
The exclamation mark within an
equilateral triangle, as shown on this page,
is intended to prompt the user to refer
to important operating or maintenance
instructions in the documentation supplied
with the product. See Figures 5 & 6.
Earthing
This is a Class I product. An Earth
connection MUST be provided in each AC
power cord.
The Earth Bolt connection at the rear of
the console should be connected to Earth
using Earth cable at least 6mm2 in cross
section (10 AWG).
Lithium Battery Replacement
Caution: Danger of explosion if battery is
incorrectly replaced. Replace only with
the same or equivalent type. Batteries
must not be exposed to excessive heat
such as sunshine, fire or the like.
This device complies with part 15 of
the FCC Rules. Operation is subject to
the following two conditions:
1. This device may not cause harmful
interference.
2. This device must accept any
interference received, including
interference that may cause undesired
operation.
FIGURE 5 - DANGEROUS VOLTAGES
FIGURE 6 - IMPORTANT INSTRUCTIONS
8 ARTEMIS Digital Broadcast Production Console
Information
Should you require any technical
assistance with your Calrec product
then please contact your regional
Calrec distributor. Customers within
the UK or Ireland should contact
Calrec directly.
For a complete list of worldwide
distributors by region, go to
www.calrec.com or contact us for
more information.
For pre-delivery technical enquiries, UK
and Ireland customers should contact the
Calrec project manager assigned to their
order. Post delivery, the Calrec Customer
Support team will take care of your
technical enquiries.
Our UK customer support team work
closely with our global distributor network
to provide the highest level of after sales
support. Your distributor should be your
first point of contact and will often be
able to provide an instant solution, be it
technical advice, spares or a site visit by
an engineer.
Calrec UK customer support and our
global technical team provide free of
charge technical support and advice by
phone or e-mail to all customers.
Once your console is installed we can
provide an engineer on site to carry out
system commissioning. Commissioning
ensures the equipment is correctly
installed and fully functioning before it
goes into use. During commissioning, our
engineers can also help and advise with
configuration and setup.
Calrec after sales support includes:
• Free of charge comprehensive
technical advice and support by phone
and e-mail.
• Software and hardware upgrades.
• Repairs.
• Quick supply of replacement or loan
hardware in the event of a failure.
• Providing export documentation for the
return of faulty parts.
• On site commissioning visits.
• On site service and health check visits.
• Emergency engineer visits.
• On site on-air support, for complete
peace of mind - providing operational
guidance, and technical engineering
support for new installations or high
profile events.
• Operational training.
• Maintenance / technical training.
• Supply of replacement components.
• Supply of documentation.
Service contracts
We offer a range service contracts to our
UK and Ireland customers, offering 24/7
telephone support, regular health checks
and extended warranty amongst other
benefits. Please contact our customer
support team for more information on
service contracts.
Product Warranty
A full list of our conditions & warranties
relating to Goods & Services is contained
in the Company’s standard Terms and
Conditions. A copy of this is available on
request.
Repairs
If you need to return goods to Calrec, for
whatever reason, please contact your
TECHNICAL SUPPORT
regional distributor or Calrec customer
support beforehand for guidance, as
well as to log the details of the problem
and receive a reference number. For
customers outside the UK and Ireland,
shipping via the distributor saves
customers from dealing with exportation
paperwork. If there is a need to send
direct to Calrec, contact us beforehand to
log the incoming repair and for assistance
with exportation documents.
Standard of Service
Ensuring the highest standards is a
priority, if you have any comments on
the level of service, product quality
or documentation offered to you by
Calrec, please contact the Calrec
Customer Support team in the UK who
will endeavour to address the issues.
Calrec welcomes all customer feedback.
For feedback specific to this document,
please contact [email protected].
[email protected]
Telephone:
Email - Technical:
Email - General:
Postal address:
Fax:
Website:
+44 (0) 1422 842159
[email protected]
Calrec Audio Ltd.
Nutclough Mill,
Hebden Bridge,
West Yorkshire,
HX7 8EZ,
U.K.
+44 (0) 1422 842159
www.calrec.com
(9:00am-5:30pm)
10 ARTEMIS Digital Broadcast Production Console
Control Surface
SURFACE DIMENSIONS AND ASSEMBLY
The Artemis control surface can be
customised in terms of width and
fader count, and can be provided with
a number of stand and trim options.
Desk-top mounting
The control surface can be supplied with
no floor stand, or if supplied, the floor
stand can be removed allow for desk-top
mounting, as shown in Figure 1.
Floor stand options
Several floor stand types are available.
The standard 'Studio' type, as shown in
Figure 2 has adjustable feet for levelling.
The 'OB' version, shown in Figure 3
allows for the stand to be bolted to the
floor, typically for use in mobile or outside
broadcast units. Note the OB version
is 7.8mm [0.31'] taller than the Studio
version. Both the Studio and OB style
are also available with a reduced height,
sitting the console 40mm [1.57'] lower
than the standard versions.
FIGURE 2 - STANDARD HEIGHT STUDIO STAND, END ELEVATION
FIGURE 1 - NO FLOOR STAND FITTED, END ELEVATION
857 [33.74”]
129 [5.08”]
384 [15.19”]
74 [2.91”]
122 [4.41”]
CALREC Putting Sound in the Picture
11
618.3 [24.34”]
573.8 [22.59”]
660.0 [25.98”]
1082.8 [42.63”]
647.8 [25.50”]
740.8 [29.17”]
766.8 [30.19”]
122
[4.41”]
74
[2.91”]
FIGURE 3 - STANDARD HEIGHT BOLT-DOWN OB STAND, END ELEVATION
Bolt-down 'OB' stands
To provide the option of securing the
control surface to the floor by its stand,
as required when fitted in mobile or
outside broadcast units, the OB style
stand replaces the adjustable feet with
extra support and 2 x 11mm [0.43'] holes
in each foot plate, as shown in Figure 4.
Note that the OB stands are slightly taller
than their studio equivalents, sitting the
control surface 7.8mm [0.31'] higher.
75.8 [2.98”]
FIGURE 4 - BOLT-DOWN OB STAND, FIXING HOLES
12 ARTEMIS Digital Broadcast Production Console
Control Surface
Reduced height stands
Both the OB and studio stands are
available in reduced height versions,
sitting the control surface 40mm
[1.57'] lower than their standard height
equivalents, as shown in Figures 5 and 6.
Surface sizes
Artemis surface sizes are stated in the
number of faders they can contain.
A number of chassis sections are fitted
together to provide a control surface of a
suitable width to contain the number of
faders required, or to fit the physical space
available. Often chassis' are ordered to
be larger than is required at the time to
allow for a future increase in the quantity
of faders.
Chassis sections come in a variety of
widths and are defined by the number
of control panels that they can contain
across their width. Chassis sections
currently available are '2', '2.5' & '3.5'
A standard Artemis layout consists of a
number of fader panels and a monitor
panel. The standard fader panel is
260mm [10.24'] wide and is fitted with
eight faders across its width. The monitor
panel is 200mm [7.87'] wide and is loosely
termed as 'half-width'
Therefore, for example, a 3.5 section can
be fitted with 3 x fader panels and 1 x
'half-width' or '.5' monitor panel.
Each frame section is as wide as the
modules it can contain, plus a 3mm
[0.118'] bulkhead at each end. Once
assembled, the overall chassis is fitted
with a side-trim at each end. The standard
side-trim is 18mm, adding 36mm [1.42'] to
the overall width.
Standard Artemis consoles are supplied
with a PC monitor screen and keyboard
tray which can be fitted on the left or right
FIGURE 5 - 40MM REDUCED HEIGHT STUDIO STAND
FIGURE 6 - 40MM REDUCED HEIGHT BOLT-DOWN OB STAND
660.0 [25.98”]
77.7
[3.06”]
119.3
[4.70”]
526.0 [20.71”]
1035.0 [40.75”]
570.5 [22.46”]
600.0 [23.62”]
693.0 [27.28”]
719.0 [28.31”]
578.3 [22.77”]
533.8 [21.02”]
660.0 [25.98”]
1042.8 [41.06”]
607.8 [23.99”]
700.8 [27.59”]
726.8 [28.61”]
119.3
[4.70”]
77.7
[3.06”]
CALREC Putting Sound in the Picture
13
FIGURE 7 - LEG MEASUREMENTS
External Leg Measurement
Internal Leg Measurement
FIGURE 8 - TOTAL SURFACE WIDTH
Total surface width (including trim)
Total surface width (including trim and monitor mount)
FIGURE 9 - TYPICAL SURFACE MEASUREMENTS
side of the chassis, as specified at order.
If required, a second PC monitor/monitor
mount (and / or keyboard tray) can be
fitted at the other end of the chassis.
PC monitor mounts attach to the side
of the chassis, outside the side trims,
increasing the overall width again by a
further 45mm [1.77'] per monitor mount
fitted..
Consoles can also be supplied without
any PC monitor mounts, minimising the
surface width but requiring the installation
provides a convenient location to display
the main application for the audio
operator.
Where surface width is critical, optional
narrower 5mm side trims (10mm [0.39']
per pair) can be fitted in place of the
standard 18mm (36mm [1.42']) trims.
Typical surface measurements
Measurements for typical surface widths
are shown in Figure 9.
Fader
Count
Section
Make-Up
Total Width
Standard trim
1 x monitor mount
Total Width
Standard trim
2 x monitor mount
Total Width
Standard trim
No monitor Mount
Total width
Thin trim (5mm)
No monitor mount
Internal Leg
External Leg
16
2.5
807mm [31.77']
852mm [33.54']
762mm [30.00']
736mm [28.98']
450mm [17.72']
610mm [24.02']
24
3.5
1067mm [42.01']
1112mm [43.78']
1022mm [40.24']
996mm [39.21']
580mm [22.83']
740mm [29.13']
32
2/2.5
1333mm [52.48']
1378mm [54.25']
1288mm [50.71']
1262mm [49.69']
840mm [33.07'] 1000mm [39.37']
40
2/3.5
1593mm [62.72']
1638mm [64.49']
1548mm [60.94']
1522mm [59.92']
1106mm [43.54'] 1266mm [49.84']
48
2/2.5/2
1859mm [73.19']
1904mm [74.96']
1814mm [71.42']
1788mm [70.39']
1140mm [44.88']
1300mm [51.18']
56
2/3.5/2
2119mm [83.43']
2164mm [85.20']
2074mm [81.65']
2048mm [80.63'] 1330mm [58.66'] 1490mm [58.66']
64
2/2/2.5/2 2385mm [93.90']
2430mm [95.67']
2340mm [92.12']
2314mm [91.10']
1330mm [58.66'] 1490mm [58.66']
72
2/3.5/2/2 2645mm [104.13'] 2690mm [105.91'] 2600mm [102.36'] 2574mm [101.34'] 1596mm [62.83'] 1756mm [69.13']
14 ARTEMIS Digital Broadcast Production Console
Control Surface
Access to surface connections
The data connections from the Artemis
processing core to the control surface
are made through a small cut-out on the
rear cover of the control surface located
near the IEC AC input connectors. Two
fibres or Cat5e cables need to be routed
through the cut-out to connect to the
Surface Switches inside the control
surface. A rear interface panel provides
power connections on three IEC's along
with a connection point for earthing the
chassis. Audio and data connections
are also provided for interfacing to audio
driven devices along with ancillary data
connections.
The format of the interface plate may vary
depending on the optional hardware fitted
within the surface. Connector and pin-out
information is provided in the Console
Connection section of this document.
Access to internal surface
components
Removing up-stand meter panels and
control surface panels gives open access
to the Surface Switches and other internal
components. Some early production
models are fitted with hinged rear covers
that allow access from the back of the
control surface.
Non-hinged rear covers can be removed,
however, care needs to be taken to
support the weight of internal components
mounted on the inside of the rear covers
and the cabling to them..
FIGURE 1 - REAR OF ARTEMIS CONTROL SURFACE
REAR CONNECTOR INTERFACE AND COVERS
Anciliary Inputs
PC interface (RJ45)
Talkback Microphone
Output (XLR Male)
Primary Surface to
Processing Rack
Connection (SFP)
Secondary Surface to
Processing Rack
Connection (SFP)
Screen/Anciliary
power
Surface Power
Headphone
Input (D25
Meter IN/OUT
connectors (x8)
Spare
Spare
CALREC Putting Sound in the Picture
15
FIGURE 1 - STAND MOUNTING POINTS
FLOOR STAND REMOVAL
If the control surface is supplied with
a floor stand, it can be removed if
required to reduce the overall size
and weight aiding installation logistics
or for where desk-top mounting is
preferred.
The floor stand is attached to the control
surface by eight bolts as highlighted in the
drawing to the right.
With the fixing bolts removed, as long as
the cross beam between the stand legs
is fitted, the stand will be stable, however
care needs to be taken whilst the surface
is not fixed to the stand. If the cross beam
is not fitted and the stand not attached
to the surface, it will be very unstable.
It is not recommended to be working
under the control surface unless it is fixed
in place.
When re-attaching the stand, ensure the
cross beam is fitted to provide stability.
Take care to align the fixings to avoid
cross-threading the bolts. The surface
MUST be correctly fastened to the stand
to prevent possible equipment damage or
personal injury.
16 ARTEMIS Digital Broadcast Production Console
Control Surface
SURFACE COMPONENTS
There are a range of components
within the surface. This section
explains how these components
are connected, receive power and
communicate with each another.
POE (Power Over Ethernet) switch
Control panels in the surface have a single
connection that carries all data and power
via an RJ45 connector from a POE switch.
The number of POE switches fitted in
a control surface is determined by the
number of panels fitted. Each POE switch
can connect to up to six control panels.
POE switches are mounted to the inside
of the rear cover and are accessible by
removing control and up-stand meter
panels, or by removing the rear covers as
shown in the Surface Dimensions and
Assembly section of this document.
Each POE switch has two AC mains
inputs and two PSU's to provide internal
and external power redundancy. 'Power
Good' LED's 1 & 2 indicate each power
supply is receiving mains and active.
A PSU failure or loss of a mains input will
generate a System Status error message.
Each POE switch has 16 RJ45
connections, split into two groups - A & B.
The A group of connectors are full POE
- carrying both data and power. Status
LED's are provided for these ports which
should display a steady, regular flashing
pattern once the system is booted and
comms have been established.
Connections P1 to P6 are used to
connect to control panels. Control panels
must be connected to the correct POE
unit and port, as defined by the Surface
Layout page in the main application. The
Surface Layout page, and other utility
software refers to these ports simply as
POE ports 1 - 6. See Figure 1.
When a surface reset command is
received by a POE switch it momentarily
cuts the power on ports P1 - P6. Control
surface panels are 'reset' by cycling power
to them.
Each POE switch requires a connection to
both the primary and secondary Surface
Switches. POE connector S1 connects to
the primary Surface Switch and connector
S2 connects to the secondary Surface
Switch. Although S1 & S2 are full POE,
power and data, Surface Switches do not
use the power from this feed.
Ports SPR1 & SPR2 are uninterrupted
during reset and are used to provide
power to the Surface Switches, PC and
any other items that may need to remain
powered during reset, such as ancillary
audio feeds. The SPR connections also
contain the reset lines from the up-stand
reset panel for the surface, control and
DSP which the active Surface Switch acts
upon accordingly. All other hardware,
such as the PC will ignore the reset lines
in the SPR feed.
The B group of connectors do not pass
data. Ports AP1 - AP4 are ancillary
power, used to power 'non-intelligent'
units with no control processor or
data connection, such as moving coil
meters. AP connections drop power
during surface reset. Artemis up-stand
TFT panels do not have a direct data
connection from a POE. They have a
connection to a fader panel which carries
out the processing and passes on the
data to the display. Due to the size of
Artemis up-stand TFT's, the fader panel
cannot power them and therefore they
require an additional connection, from a
POE AP port for power only. See Figure 2.
FIGURE 1 - POE SWITCH
P1
P2
P3
P4
P5
P6
S1
S2
USB
YZ5706 - POE SWITCH
P
S
AP
SPR
RST
AP1
AP2
AP3
AP4
SPR1
SPR2
RST
RST
A
B
2
1
POWER
GOOD
A
B
AC IN 1
AC IN 2
P1
P2
P3
P4
P5
P6
S1
S2
Panel
Surface switch
Ancillary Power
Surface switch
Power & Reset
Reset
-
-
-
-
-
Serial number
CALREC Putting Sound in the Picture
17
P1
P2
P3
P4
P5
P6
S1
S2
USB
YZ5706 - POE SWITCH
P
S
AP
SPR
RST
AP1
AP2
AP3
AP4
SPR1
SPR2
RST
RST
A
B
2
1
POWER
GOOD
A
B
AC IN 1
AC IN 2
P1
P2
P3
P4
P5
P6
S1
S2
Panel
Surface switch
Ancillary Power
Surface switch
Power & Reset
Reset
-
-
-
-
-
Serial number
AP Connections to upstand
TFT & moving coil meters -
power only
Upstand TFT connection
via DVI cable - data only
(Not DVI compatible!)
P1-P6 Panel connections -
data & power
FIGURE 2 - POE TO PANEL CONNECTIONS
18 ARTEMIS Digital Broadcast Production Console
Control Surface
POE Reset connections
The two ports labelled RST are used
to pass hard reset lines between the
POE's. The reset lines originate from
the up-stand reset panel and are wired
to the 'Reset and Meter' connector on
the monitor panel via a D25 cable. This
cable's pin-out is shown in Figure 3. The
monitor panel's 'Reset' RJ45 connector
outputs the reset signals and is wired to
a POE RST port, the other RST port is
used to pass the signals on to the next
POE and so on, daisy-chaining the signal
through all the POE switches.
It does not matter which RST is used
for 'in' & 'out' or in what order the POE's
are connected. These are hard logic
lines rather than data, ensuring reset
commands can be passed throughout
the system irrespective of the functioning
state of each piece of hardware.
FIGURE 4 - POE RESET CONNECTIONS
Cat5e Reset Cable
D25 Reset Cable
FIGURE 3 - RESET CONNECTION
Function
Pin
Control Reset
9
DSP Reset
22
Reset LED
10
Surface Reset
23
Common
14, 15, 16, 17, 18, 19,
20, 21, 13
25 24 23 22 21 20 19 18 17 16 15 14
13 12 11 10 9
8
7
6
5
4
3
2
25 Pin Female D-Type - Wiring side of connecting cable
1
25 Pin Male D-Type - Wiring side of connecting cable
15 16 17 18 19 20 21 22 23 24 25
14
10 11 12 13
9
8
7
6
5
4
3
2
1
During surface reset, all POE's & Surface
Switches reboot and power is momentarily
dropped to all panels forcing them to
reboot. DSP and control resets are
passed on to the processing core via
the active Surface Switch.
All Calrec fitted Cat5e cables are wired
'straight-through' or 'pin to pin' Panel
cables and I/O to Router cables can be
either straight-through or cross-over,
however POE RST and SPR cables MUST
be wired straight-through.
CALREC Putting Sound in the Picture
19
Surface Switches
The Surface Switch is the interface
between the control surface and the
processing core. To provide redundancy,
two Surface switches are fitted, primary
and secondary. The system will always
attempt to boot and run on the primary,
however if there is a problem with the
primary or its connections, the secondary
will automatically take over.
Like POE's, the Surface Switches are
mounted to the inside of the rear cover,
usually in the same section as the IEC
inlets. Access is gained by removing
control panels or the rear cover as shown
in the surface dimensions section of this
document. When viewed from the front,
the primary Surface Switch is always the
left hand unit. See Figure 5.
To communicate with all the control panels
and PC, each Surface Switch requires a
direct connection to each POE switch.
POE switches MUST be connected to
specific ports in the correct order:
POE #1 connects to surface switch port
PS1, POE#2 to PS2, POE #3 to PS3 etc.
POE's are numbered by location from
left to right across the console. Figure 6
shows the correct data connections for a
3 x POE system. On each POE, port S1
connects to the primary Surface switch,
port S2 to the secondary. LEDs 1 - 6
show activity on these ports and should
display a regular flashing pattern once
booted and comms established. Although
the POE sends power down these lines,
the Surface Switches do not use it.
Any POE SPR ports can be used to feed
Surface Switch PR1/PR2 ports to power
the Surface Switch as well as passing on
the reset signals. LEDs I/P1 and I/P2
indicate if power is present on these ports.
Ports A & B are SFP slots Port A is used
to interface with the Control Processor
in the processing core, port B is currently
unused. The primary Surface Switch
should connect to the primary Control
Processor's 'Surface 1' connector (MAC7
for the 8U or older 4U Control Processor
design) . The secondary Surface
Switch should connect to 'Surface 1'
on the secondary Control Processor.
These connections are NOT supplied
by Calrec and need to be made by the
installer. Please see the Surface to Core
Connection section of this document for
more details.
USB
YZ5716-2
Surface Switch
IP
PS
PR
PS1
PS2
PS3
PS4
PS5
PS6
PR1
PR2
- Input Power
- POE Switch
- Power & Reset
IP2
2
4
6
1
3
5
IP1
A
B
Serial number
FIGURE 5 - SURFACE SWITCH
Primary
Surface
Switch
Secondary
Surface
Switch
POE #1
POE #2
POE #3
FIGURE 6 - POE TO SURFACE SWITCH DATA CONNECTIONS
20 ARTEMIS Digital Broadcast Production Console
Control Surface
Artemis control surfaces have 3 x IEC
AC mains inputs requiring 100–240V
AC.
The AC power inlets are wired internally to
three distribution blocks mounted to the
base of the inside of the control surface.
The POE switches have dual power
supplies for redundancy and take two
AC inputs, one from each of the first
two mains sources. The majority of the
remaining hardware in the control surface,
SURFACE AC POWER CONNECTIONS
P1
P2
P3
P4
P5
P6
S1
S2
USB
YZ5706 - POE SWITCH
P
S
AP
SPR
RST
AP1
AP2
AP3
AP4
SPR1
SPR2
RST
RST
A
B
2
1
POWER
GOOD
A
B
AC IN 1
AC IN 2
P1
P2
P3
P4
P5
P6
S1
S2
Panel
Surface switch
Ancillary Power
Surface switch
Power & Reset
Reset
-
-
-
-
-
Serial number
P1
P2
P3
P4
P5
P6
S1
S2
USB
YZ5706 - POE SWITCH
P
S
AP
SPR
RST
AP1
AP2
AP3
AP4
SPR1
SPR2
RST
RST
A
B
2
1
POWER
GOOD
A
B
AC IN 1
AC IN 2
P1
P2
P3
P4
P5
P6
S1
S2
Panel
Surface switch
Ancillary Power
Surface switch
Power & Reset
Reset
-
-
-
-
-
Serial number
P1
P2
P3
P4
P5
P6
S1
S2
USB
YZ5706 - POE SWITCH
P
S
AP
SPR
RST
AP1
AP2
AP3
AP4
SPR1
SPR2
RST
RST
A
B
2
1
POWER
GOOD
A
B
AC IN 1
AC IN 2
P1
P2
P3
P4
P5
P6
S1
S2
Panel
Surface switch
Ancillary Power
Surface switch
Power & Reset
Reset
-
-
-
-
-
Serial number
MU5734
1
md
04/03/08
Approved
Calrec
Alpha
RTW meter 10600
Meter Module
..
..
Meter
PSU
POE
POE
POE
PC MONITOR
Surface AC inputs
1
2
Anc
SURFACE POWER - AC
including the PC is DC powered via POE
connections.
The third IEC input and distribution block
is used to power ancillary or third party
items with a single mains input, such as
DK/RTW meters and PC monitors.
To ensure all equipment is powered and
redundancy is applied where available,
all three IEC inputs to the control surface
need to be fed with 100–240V AC. If only
one of the first two inputs is fed, System
Status error messages will be generated
by each POE indicating they are not
receiving power on both inputs.
It is recommended that these two mains
inputs are fed from two separate AC
supplies where possible to provide
redundancy against external power failure.
CALREC Putting Sound in the Picture
21
The surface switches and
configuration PC take DC power via
RJ45 connectors. These should be
fed from SPR connections on POE
switches. These connections are
for power only—no data is carried
over the POE SPR connections.
SPR connections do not drop power
during surface reset.
The power input connectors on the
surface switches are labelled PR1
and PR2. Only one input needs to be
connected for full functionality and
redundancy. If power to the primary
surface switch is lost, or the switch
fails, data is automatically routed via the
secondary Surface Switch. Therefore the
two surface switches should be powered
from two different POE units to maintain
overall console functionality in the event of
a failure of a POE feeding power.
The PC is powered via a DC convertor
unit. This unit has two power inputs on
RJ45s for the PC. Only one of these
is required for operation, the second is
provided for power redundancy. These
connections should be fed from two
different POE's. SPR connections on
POE's should be used so the PC power
is maintained during surface reset. The
PC power convertor outputs 12V DC via a
9 way D-type connector. This wires via a
momentary switch in the keyboard tray to
the PC's DC input jack. The switch acts as
a PC reset by interrupting the power.
The PC has 2 DC input jack sockets,
either can be used. Only one DC
connection to the PC itself is provided
as the redundancy is catered for by the
power convertor unit.
The PC power convertor box also contains
the headphone driver circuitry and has a
3rd RJ45 power input for this, situated
in the bottom row of connectors. The
headphone driver can be powered from an
SPR port or an AP depending on whether
or not power needs to be maintained
during surface reset.
SURFACE POWER - DC
Control panels take power and data on
the same RJ45 connection and therefore
need to be connected from a P1–P6 POE
port.
P1
P2
P3
P4
P5
P6
S1
S2
USB
YZ5706 - POE SWITCH
P
S
AP
SPR
RST
AP1
AP2
AP3
AP4
SPR1
SPR2
RST
RST
A
B
2
1
POWER
GOOD
A
B
AC IN 1
AC IN 2
P1
P2
P3
P4
P5
P6
S1
S2
Panel
Surface switch
Ancillary Power
Surface switch
Power & Reset
Reset
-
-
-
-
-
Serial number
P1
P2
P3
P4
P5
P6
S1
S2
USB
YZ5706 - POE SWITCH
P
S
AP
SPR
RST
AP1
AP2
AP3
AP4
SPR1
SPR2
RST
RST
A
B
2
1
POWER
GOOD
A
B
AC IN 1
AC IN 2
P1
P2
P3
P4
P5
P6
S1
S2
Panel
Surface switch
Ancillary Power
Surface switch
Power & Reset
Reset
-
-
-
-
-
Serial number
P1
P2
P3
P4
P5
P6
S1
S2
USB
YZ5706 - POE SWITCH
P
S
AP
SPR
RST
AP1
AP2
AP3
AP4
SPR1
SPR2
RST
RST
A
B
2
1
POWER
GOOD
A
B
AC IN 1
AC IN 2
P1
P2
P3
P4
P5
P6
S1
S2
Panel
Surface switch
Ancillary Power
Surface switch
Power & Reset
Reset
-
-
-
-
-
Serial number
USB
YZ5716-2
Surface Switch
IP
PS
PR
PS1
PS2
PS3
PS4
PS5
PS6
PR1
PR2
- Input Power
- POE Switch
- Power & Reset
IP2
2
4
6
1
3
5
IP1
A
B
Serial number
USB
YZ5716-2
Surface Switch
IP
PS
PR
PS1
PS2
PS3
PS4
PS5
PS6
PR1
PR2
- Input Power
- POE Switch
- Power & Reset
IP2
2
4
6
1
3
5
IP1
A
B
Serial number
Serial number
PC5787
POE SW 1
SPR1/2
POE SW 2
SPR1/2
PC POWER (+12V)
+ PC RESET
POE SW
SPARE PWR
BALANCED
ANALOG INPUTS
HEADPHONE
OUTPUTS
PC & Headphone Driver
Power Convertor
PC
PC Reset Switch
POE Cat5 Surface Switch Power
POE Cat5 Headphone Driver Power
POE Cat5 PC Power
12V PC Power
Upstand TFT meter panels, moving coil
meters and miscellaneous optional panels
take power via POE AP ports.
SURFACE SWITCH, PC AND HEADPHONE DRIVER POWER
22 ARTEMIS Digital Broadcast Production Console
Control Surface
Cat5e network cabling inside the
control surface is ID coded at both
ends with a number of cable markers.
One marker is used on each to ID the
function of the cable by colour, matching
the colour key used for the connector
labelling on the POE switch - for example
the data connection to the primary surface
switch has a green marker and the one to
the secondary has a yellow one.
Depending on the function of the cable,
some have a prefix and/or suffix to the
function marker.
Prefixes are used to identify the control
surface section the related POE is fitted
in. Viewing the console from left to right,
the first frame section is 'A', second is
'B', third is 'C' etc. Where there is more
than one POE switch fitted in a section,
two letters are used to prefix the label,
for example 'AA' & 'AB' where AA is the
first POE in the first section and AB is the
second POE in the first section.
Panel connection cables use a suffix to
ID the POE port. For example, if a cable
is labelled 'A11'—The prefix 'A' refers to
the POE switch in section 1. The next
character '1' is a colour marker (brown) to
identify the cable as a panel connection,
and the last character, or suffix - '1' refers
to port P1.
Blue SPR connections use a suffix to
identify the device being powered by the
POE switch.
The table to the right lists the functions
with prefix and suffix by colour ID. Figures
2 & 3 give examples of the cable labels
that would be used for the first POE's A &
B group of ports.
A 1 2
Color ID
Prefx
Sufx
P1
P2
P3
P4
P5
P6
S1
S2
USB
YZ5706 - POE SWITCH
P
S
AP
SPR
RST
AP1
AP2
AP3
AP4
SPR1
SPR2
RST
RST
A
B
2
1
POWER
GOOD
A
B
AC IN 1
AC IN 2
P1
P2
P3
P4
P5
P6
S1
S2
Panel
Surface switch
Ancillary Power
Surface switch
Power & Reset
Reset
-
-
-
-
-
Serial number
A 1 2
A 1 21
A 1 213
A 1 4
A 1 5
A 1 6
A 4
A 5
P1
P2
P3
P4
P5
P6
S1
S2
USB
YZ5706 - POE SWITCH
P
S
AP
SPR
RST
AP1
AP2
AP3
AP4
SPR1
SPR2
RST
RST
A
B
2
1
POWER
GOOD
A
B
AC IN 2
P1
P2
P3
P4
P5
P6
S1
S2
Panel
Surface switch
Ancillary Power
Surface switch
Power & Reset
Reset
-
-
-
-
-
Serial number
A 3
A 3
A 3
A 3
2
2
x
6
x
6
FIGURE 2 - POE 'A' CONNECTIONS
FIGURE 3 - POE 'B' CONNECTIONS
CONTROL SURFACE CAT5 CABLE CODING
FIGURE 1 - ID CODED NETWORK CABLE
A
1
A
A
A
1
1
2
3
4
5
6
Color ID
Control panel connection, data & power
Prefix
Suffix
Reset connection (RST)
Ancillary power (AP1-4)
Secondary Surface Switch (S2), data
Primary Surface Switch (S1), data
Uninterrupted power + reset (SPR1-2)
Section
ID
1-6, relates to
POE P1-P6 port ID
Section
ID
Section
ID
Section
ID
None
None
None
None
None
None
1 = Primary Surface Switch
2 = Secondary Surface Switch
3 = PC Power 1
4 = PC Power 2
Function
CALREC Putting Sound in the Picture
23
A high quality, low power fanless PC
is mounted to the baseplate inside
the control surface. The design of the
PC used ensures reliability alongside
minimal heat and acoustic noise.
The PC is supplied as standard with a
traditional magnetic hard drive (HDD) or
as an option can be supplied with a solid
state drive (SSD). SSDs have no moving
parts and are therefore quieter and more
shock-resistant than traditional HDDs.
The system PC is not relied upon - it
does not carry out any audio or control
processing. The control surface, control
and audio processors all boot and are fully
functional irrespective of whether the PC
is on or connected.
The PC is used as an interface, providing
a comprehensive GUI for control as well
as being used for configuration and
diagnostics.
The PC monitor and keyboard tray are
fitted at the right hand side of the control
surface as standard. As an option,
consoles can be ordered with keyboard
and monitor at the left side of the surface.
The keyboard tray slides out from
SYSTEM PC
underneath the fader bed. If required, 2
PC monitors and / or keyboard trays can
be fitted, one at each end of the control
surface. The second set would typically
be used as a convenient location for
the operator to display / control other,
non-Calrec PC's. Consoles can also be
supplied without the monitor mount and
/ or keyboard tray, this is usually done
when space is restrictive. In such a case,
the installer should provide a suitable
alternative to view and control the system
PC.
PC power and reset
The PC should start up automatically
when the control surface is powered.
The Windows shutdown procedure should
be followed whenever possible before
removing power to the control surface.
A reset switch for the PC is located at the
back of the keyboard tray.
The power supply for the PC is located
in the adjacent unit which also contains
the headphone drivers. The PC power
supply inputs POE DC voltage via RJ45s
and outputs 12V DC on a 9 pin D-type
connector. Two input connections
provide redundancy against power loss
and should be fed from two different
POE switches, using their SPR feeds to
maintain power to the PC during surface
reset. The 9 pin connector also contains
a reset line for the PC which wires out to
a switch in the back of the keyboard tray.
The power input to the PC itself is via a
DC jack socket.
System network data connection
The PC connects to the system in the
same way as a control panel. The RJ45
Ethernet port on the PC itself is its data
connection to the system and can connect
to any available POE switch port P1–P6.
Note that P1–P6 ports are full POE and
contain power. The PC's supplied do not
take power from this connection, however
they are designed to be protected from
damage by POE voltage. Connecting
other PC's or equipment to a POE switch
may damage them. The Ethernet-USB
adaptors supplied with the console (as
shown in Figure 2) are POE protected and
can be used to connect a replacement or
backup PC via the backup / replacements
USB port if required. One of these
adaptors is supplied loose along with the
miscellaneous items such as the backup
discs and hex screwdrivers.
Serial number
PC5787
POE SW 1
SPR1/2
POE SW 2
SPR1/2
PC POWER (+12V)
+ PC RESET
POE SW
SPARE PWR
BALANCED
ANALOG INPUTS
HEADPHONE
OUTPUTS
PC power input 1
POE PC power input 1
POE PC power input 2
12V power output to PC
POE Headphone driver power
PC 12V DC input
PC reset button
System PC
PC power & reset cable
Keyboard
Mouse
4 x USB
Serial port
Ethernet port - data connection
to system via POE panel port
VGA monitor
output
PC POWER AND RESET
1
2
6
7
3
4
8
9
5
9
8
7
6
9 Pin Male D-Type - Wiring side of connecting cable
1
2
3
4
5
Pin
Wired to
Signal
Reset
+12V
+12V
+12V
+12V
0V
0V
0V
0V
DC jack center pin
DC jack outer
Reset switch normally open
Reset switch Common
No connection
No connection
No connection
No connection
No connection
24 ARTEMIS Digital Broadcast Production Console
Control Surface
As an option, the console can be supplied
with an additional accessible USB port,
wired internally via an adaptor to a POE
panel port, allowing for a backup PC to be
connected quickly.
LAN connection
An RJ45 socket on the rear interface
panel labelled 'PC I/F' provides a second
network connection to the PC. Internally,
this wires via a USB-Ethernet adaptor
which is fitted into a USB port on the PC.
If connecting to a LAN or the internet,
the security / firewall settings can be
selected per connection. Security /
firewall settings should NOT be changed
for the main system network port -
'CalrecDeskConnection'.
Providing an internet connection to the
PC allows Calrec engineers access for
diagnostics by agreement using a secure
connection.
Keyboard and mouse
As standard, a keyboard with trackball
(or alternatively trackpad) is located in
the pull-out keyboard tray under the
fader bed. The keyboard has two colour
coded PS2 connectors which fit directly
in the PS2 ports on the PC. UK and US
keyboard layouts are available.
Touchscreen monitor
The PC monitor is AC mains powered
(100-240V) by a single IEC input, wired
via the ancillary AC input to the control
surface. The graphics output from the PC
to the monitor is a direct VGA connection.
Touch data from the monitor is connected
by USB. To correctly display all the Calrec
PC applications, a minimum resolution
of 1280 x 1024 is required. Using an
alternative higher resolution monitor such
as 1920 x 1080 will display the Calrec
software correctly but the content will
not scale up higher than the 1280x1024
monitor size it was designed for.
Accessible PC USB port
The USB port on the up-stand reset panel
is connected internally to a PC USB port
providing easy access for USB devices,
for example for making backups of shows
/ user memories to a USB memory stick.
Operating system
Calrec system PC's are supplied with
Microsoft Windows 7 Professional
installed. Calrec software is currently
tested using the Windows 7 and Windows
XP Professional platforms and we cannot
guarantee functionality using any other
operating system.
3rd Party software
Even though the PC is not required for
operation of the system, Calrec does
recommend that the PC is regarded as
an integral control device for the system.
It should not be used as a general
purpose PC. If 3rd party software is
installed on the PC, care must always be
taken to ensure that it does not interfere
with the normal performance of the PC.
The installation of inappropriate software
on the PC may invalidate the console
warranty.
Serial port
The current specification PC has one
external serial port. This is connected
to the DK meter serial port when fitted
to allow convenient access for DK
configuration in the factory.
Antivirus Protection
Antivirus protection is not pre-installed on
console and router core PCs as standard
but if you wish to protect your PC you
can install a package of your choice.
Exceptions will need to be configured
within the antivirus software to allow the
following to communicate with the Calrec
system:
• C:\Calrec\WindowsService\
DeskPcWs.exe
• C:\Calrec\ProgramUpdater\Calrec.
ProgramUpdater.exe
FIGURE 2 - USB TO ETHERNET
CALREC Putting Sound in the Picture
25
Any standard specification modern
PC running Windows 7 or Windows XP
Professional can be used as a backup
or replacement to connect to the
console and run the various Calrec
applications.
Connection by the PC's USB port, via
the supplied USB-Ethernet adaptor into
a spare POE switch P1–P6 port ensures
the PC's network port is not damaged
by POE power. Note, not all available
USB-Ethernet adaptors have protection
against POE power, please refer to the
manufacturers specification if not using
ones supplied by Calrec.
Starting the Calrec Main Application on a
second PC will disable it on the first PC.
If using a laptop, or a different monitor
screen to the one supplied, a minimum
screen resolution of 1280 x 1024 is
required to display the Calrec software
correctly. Currently, such pixel height is
not widely supported by budget range
laptops. Using an alternative higher
resolution monitor such as 1920 x 1080
will display the Calrec software correctly
but the content will not scale up higher
than the 1280x1024 monitor size it was
designed for.
Calrec can supply pre-configured laptops
and replacement PC's ready to work
out of the box. The setup instructions
on this page can be used to configure
a non-Calrec supplied PC. Minimum
requirements for the PC are listed below.
ARTEMIS BACKUP PC SETUP FOR WINDOWS XP (WINDOWS 7 IS SIMILAR)
1. Download the latest version of Java Runtime Environment from www.java.com and
install it on the Backup PC.
2. Download the latest version of .net Framework from www.microsoft.com/net and
install it on the Backup PC.
3. Copy folder C:\Calrec from the Console PC onto the C: drive of the Backup PC.
4. Copy the folder Drivers\WINXP\32 BIT from the DUB E-100 Ethernet to USB
adaptor installation CD onto the C: drive of the Backup PC
5. Plug the USB connection of the DUB E-100 USB network adapter into the Backup
PC. Windows will automatically detect and start to install it. When prompted, select
Install from a specific location and browse to the location the drivers were copied
to in the previous step. Follow the on-screen prompts to complete the installation
6. Once the DUB E-100 has been successfully installed, go to
Start>Control Panel>Network Connections, right click on the connection
which uses the DUB E-100 and choose Rename. Rename the connection to
CalrecDeskConnection (case sensitive) and click OK.
7. Right click on CalrecDeskConnection and select Properties, this will open the
Network Properties window. Scroll down the list to find Internet Protocol (TCP/
IP) and double click on it. Select Use the following IP address. In the IP address
field enter xxx.yyy.135.0 (where xxx.yyy match the first two bytes of the console IP
address. If uncertain, open the Calrec program updater application which will list all
the IP's in the system. They all have the same first two bytes). In the Subnet Mask
field enter 255.255.0.0, leave all other fields blank. Click on OK.
You will be returned to the Network Properties window
8. Select the Advanced tab and click on the Windows Firewall Settings button. Turn
the firewall off and click OK to confirm, then OK again to exit Network Properties.
9. Navigate to C:\Calrec\WindowsService on the Backup PC and double click on
install.bat.
10. Go to Start>Control Panel>Administrative Tools>Services. Right click on
CalrecService and click Start.
11. Go to Start>Control Panel>System and open the Computer Name tab and make
a note of the full computer name. Go to Start>Run and type cmd then press
. This will open a DOS command prompt. At the prompt type c: and press
, then type Calrec\Utils\setcacls then press . When prompted
enter the full computer name and press .
12. Connect the DUB E-100 to the console using a spare panel port (P1–P6) on one of
the POE switches.
13. Navigate to C:\Calrec\ConsolePC on the Backup PC and double click on run.bat.
This will open the Main Application. Note that the Main Application and Program
Updater should not be running on the Console PC whilst the Backup PC is in use.
BACKUP PC
MINIMUM PC SPEC
CPU
HDD
RAM
OS
Ports
1.6 GHz Dual Core
160 GB
1GB
Windows XP Pro
1 x USB or 1 x POE protected Ethernet port
28 ARTEMIS Digital Broadcast Production Console
Processing Core – Beam / Shine
CORE DIMENSIONS AND MOUNTING
The Artemis Shine/Beam processing
core is an 8U 19' rack mount
enclosure designed for installation in
standard 19' equipment bays.
Airflow
The core is cooled by fan assisted
convection. Air is drawn in from the front
into the cable-tray and up through the
base of the card frame. Fans mounted
in the top of the core pull air through the
card frame which then exits through vents
across the top of the rear of the core. All
fans are speed monitored and System
Status error message are generated
for any failures. To ensure air can flow
through the card frame freely, the air
vents at the rear of the core should be
left clear and unobstructed. Also, the
cable-tray should not be overfilled, leaving
space at the base of the card-frame by
using the cable-tidy clips in the cable tray.
No clearance is required above or below
the core for cooling.
Acoustic Noise
A fully populated core has been measured
to produce <40dB acoustic noise
(A-weighted at 1 metre from front).
Support
The weight at the rear of the core should
be adequately supported to prevent
stress on the front racking angles. This is
particularly important when the units are
mounted in mobile installations. Calrec
will not accept liability for damage caused
by insufficient support.
Connections
All connections, including power are made
to the front of the core which is recessed
from the racking angles to allow cable
clearance within the bay.
A cable tray in the base of the core allows
for cables to be routed from the rear of
the bay to the front of the core. Cable tidy
SIDE PROFILE VIEW - DIMENSIONS & AIR FLOW
498mm [19.61”]
8 U
356mm
[14.02”]
27mm
[1.06”]
Air exits
through
rear vent
Air enters through the
front of the cable-tray
Cable entry
80mm
[3.15”]
Cable path
clips in the cable tray keep cables at the
base ensuring airflow into the cardframe is
not restricted.
When routing cables through the
cable tray and up to front panel
connectors, observe the minimum
bend radii recommended by the cable
manufacturers. This is especially
important for fibres and high speed data
conductors.
CORE SPECIFICATIONS
Take care also to 'dress' cables neatly so
that they cause minimal restriction to the
air flow.
Please refer to the Hydra2 installation
manual for detail regarding specific router
connections.
ED5708 Core
Height
8U (356mm)
Depth
498mm
Width
19'
Weight
17kg (max)
Heat Dissipation
300W (max)
CALREC Putting Sound in the Picture
29
CARD TYPES & LAYOUT
Card layout
The Artemis Shine / Beam core has 10
module / card slots. A slot should only be
fitted with a module of the correct type for
the slot. Slots are labelled for their type
across the top.
Two of each type of processing card
are fitted to provide comprehensive
redundancy. The left hand card of each
pair, labelled #1 is the primary / normally
active card. The right hand of each pair,
labelled #2 is the secondary, hot-spare
card.
A second pair of router cards can be fitted
in the expansion slots if required to double
the number of Hydra2 I/O ports available.
Both PSU cards when fitted are active
and share the load of the whole core.
Only one PSU is required to power the
core however we recommend that both
are fitted and fed to provide redundancy.
Reset, sync interface & fan status
Across the top of the card frame are the
resets and sync interface. Three buttons
can individually reset the control, router
and DSP cards within the core. A fourth
button is the enable which must be
pressed at the same time as any of the
resets as a safety precaution. Be cautious
if resetting the routers/expanders, other
consoles on the same Hydra2 network
may be using I/O connected to the routers
in the core being reset.
FRONT VIEW - FULLY POPULATED 8U ARTEMIS SHINE / BEAM CORE
Air intake and cable-tray
Cable-tidy clips
30 ARTEMIS Digital Broadcast Production Console
Processing Core – Beam / Shine
4 x BNC connectors provide sync inputs,
allowing for redundancy and a range of
formats. Two inputs are for SD / HD
video sync signals, one for AES DARS and
one for TTL Wordclock.
The upper section of the core also
contains LED indication to show the
status of the fans fitted within. Failures
are also reported by the console's System
Status.
Installing / removing cards
To remove a module from the core, take
hold of both top and bottom card handles,
press both of the red latches and open the
card handles outwards to lever the module
away from the backplane connectors.
The module can then be slid out of the
core. Avoid touching any exposed parts
of the circuit board unless observing ESD
precautions.
To install a module, line up the card edges
with the card guides in the core slot and
gently slide it in. Ensure the handles are
in the open position and push the card
POK
MA
RST
NOK
ST2
PRI
MOK
ST1
fully into the core whilst closing the card
handles to lever the module into place.
A click should be heard when the module
is seated fully.
Standard Status LED's
Control, DSP and router cards have a
standard set of front panel status LED's.
Depress red latches
Open card handles
outwards to lever
the module out.
Close card handles
inwards to lever the
module into place
• POK - Power OK, module is receiving
power.
• MA - Module active. Indicates which of
the primary / secondary pair is actively
in control.
• PRI - Indicates if the module is fitted in
a primary slot.
• RST - Illuminates when the module
receives a reset command.
• MOK - Module OK. Indicates the
module has booted and is running,
either actively or as a hot-spare.
• NOK - Neighbour OK. Indicates the
presence and status of the alternate
card of the same type. Neighbours
are primary / secondary counterparts,
rather than physically adjacent
modules.
• ST1 & ST2 are Calrec engineering
status LED's, the function of which
varies by card type and can be subject
to change with software version.
CALREC Putting Sound in the Picture
31
Master Control processor
Slots 4 & 5 are for control processor
modules, slot 4 for the primary / normally
active card, slot 5 for the secondary / hot-
spare. The active Control Processor is the
central processor in the system, handling
all control parameters and directing data
between control surface, DSP and router.
At the top of the module are two SFP
slots that can be fitted with copper or
fibre SFP's for interfacing with the control
surface. The left hand 'MAC7' SFP on the
primary Control Processor connects to
the primary surface switch, MAC7 on the
secondary Control Processor connects
to the secondary surface switch. MAC6
connectors are only used for very large
control surfaces fitted with a second
pair of surface switches, or to connect a
sidecar containing its own pair of surface
switches.
If the core is configured as a Master
Router core, RJ45 ports MAC 3, 4 & 5
allow for the connection of standalone
(outside of a console) PC's to access the
H20 network administrator GUI.
USB ports, keyboard, mouse and VGA
connections are for use only by, or under
the guidance of Calrec engineers.
As well as the standard status indicators,
front panel LED's are also provided to
show the status of other cards in the core:
D0 for the primary DSP card; D1 for the
secondary; R0 for the primary router;
R1 for the secondary; E0 for the primary
expansion card; and E1 for the secondary.
The CF LED indicates write activity to the
module's compact flash card and LOW
BATT is a low battery warning for the
module's BIOS. The Control Processor's
ST1 & ST2 LED's indicate heartbeats
from the module's two processing cores.
MASTER CONTROL PROCESSOR
DSP
The primary, normally active DSP card fits
in slot 3, the secondary, hot-spare in slot 6.
DSP cards are not required in standalone
router cores without a control surface.
This audio processing module has no front
panel connectors. All audio and data is
passed to / from the Control Processor
and router cards via the core backplane.
As well as the standard status LEDs,
LEDs D1–D8 indicate the status of the
signal processing cores within the module.
DSP
POK
MA
PRI
RST
MOK
NOK
ST1
ST2
D1
D2
D3
D4
D5
D6
D7
D8
DSP MODULE
32 ARTEMIS Digital Broadcast Production Console
Processing Core – Beam / Shine
ST1
ST2
ST3
ST4
ST5
ST6
AC IN
USB
POK
ST0
PSU
Power Supply
Card slots 9 & 10 are for PSU modules.
Both slots share the power load for the
whole core. One PSU module is sufficient
to power the whole core, two are fitted to
provide redundancy.
Each card has an IEC AC mains input
connector, requiring 100–240V AC.
Router / Expander
The primary, normally active router card
fits in slot 2, the secondary in slot 7. As
an option, slots 1 and 8 can be fitted with
additional router modules of the same
type to double the number Hydra2 I/O
ports in the core.
The Artemis Shine / Beam router card
has 16 SFP ports that can be fitted with
copper or fibre SFP's to allow connection
of Hydra2 I/O boxes and connections to
other consoles' routers and standalone
router cores. A single RJ45 port labelled
Ethernet allows for the connection of 3rd
party equipment supporting the SW-P-08
or Ember protocols for remote control.
As well as standard status LED's there are
front panel LED indicators to show activity
on each port.
ROUTER / EXPANDER
POK
MA
PRI
RST
MOK
NOK
ST1
ST2
9
11
13
15
10
12
14
16
1
3
5
7
2
4
6
8
10
9
12
11
14
13
16
15
2
1
4
3
6
5
8
7
ETHERNET
LINKS
LINKS
PSU MODULE
ROUTER/EXPANDER MODULE
34 ARTEMIS Digital Broadcast Production Console
Processing Core – Light
CORE DIMENSIONS AND MOUNTING
SIDE PROFILE VIEW - DIMENSIONS AND AIR FLOW
SIDE PROFILE VIEW - DIMENSIONS WITH REAR SUPPORTS FITTED
OVERHEAD VIEW
The Artemis Light processing core
is a 4U 19' rack mount unit designed
for installation into standard 19'
equipment bays.
Airflow
The core is cooled by fan assisted
convection. Air is drawn in through
inlets at the base/front and exits via 3
fans mounted to the rear of the core.
The speed of each fan is monitored and
System Status error reports are generated
for any failures. Air inlets and fans should
be left clear and unobstructed to ensure
air can flow through the card frame.
No clearance is required above or below
the core for cooling.
Support
The weight at the rear of the core should
be adequately supported to prevent
stress on the front racking angles. This is
particularly important when the units are
mounted in mobile installations. Calrec
will not accept liability for damage caused
by insufficient support.
Calrec supply adjustable rear support rails
with each Artemis light core that can be
fitted during installation if required. The
support rails can be fitted in different
positions depending on the depth of the
bay being used. Rear racking angles slide
over the support rails so the depth can be
adjusted to match the position of the rear
core fixings in the equipment bay.
Air drawn in through inlets at the base/front and exits via 3 rear-mounted fans
CALREC Putting Sound in the Picture
35
CARD TYPES & LAYOUT
Connections
All connections, including power are
made to the front panels of the cards
fitted within, which are recessed from the
front of the core to allow cable clearance
within the bay.
Card layout
The Artemis Light core has 9 module /
card slots. A slot should only be fitted
with a module of the correct type for the
slot, as shown in the layout above. Labels
indicating each slot's type are visible once
a module is removed.
The central module in the core is the
reset and sync interface card. Two slots
are provided for each type of processing
card for redundancy. Slots to the left of
the central reset card are for primary and
normally active router, DSP and control
processors. The slots to the right mirror
this layout and are for the secondary or
hot-spare processing modules. The first
and last slots are for power supplies,
a PSU in either slot can power a fully
populated core. Two PSU's are fitted and
the load shared to provide redundancy.
FRONT VIEW - POPULATED CORE
Installing / removing cards
Modules are fixed in place by two captive
front panel screws, one top and one
bottom. To remove, unfasten the screws
until they are loose then pull on the card
handle. It is important to observe ESD
precautions when handling any of the
cards. Avoid touching the circuit board
and use ESD bags or mats to put modules
on.
36 ARTEMIS Digital Broadcast Production Console
Processing Core – Light
Standard status LEDs
• Active - all modules (apart from the
PSU), indicate when the module
is actively in control of the system.
Modules in hot-spare mode, ready to
take over in the event of a failure, do
not have their active LED lit.
• Module OK - indicates the module
booted, and is running either actively or
as a hot-spare.
Control Processor Module
Control Processors are located in slots
4 & 6 on either side of the reset & sync
card. The left hand slot is for the primary,
normally active card, the right hand slot for
the secondary, hot-spare card.
Two SFP slots at the top of the module
can be fitted with copper or fibre SFPs
and are the data connection point for
the control surface. The 'Surface 1'
port of the primary control processor
connects to the primary surface switch
within the control surface. 'Surface 1'
on the secondary Control Processor
card connects to the secondary surface
switch. 'Surface 2' ports are only used
for very large consoles with a second
pair of surface switches, or for sidecars
containing their own surface switches.
Any of the 3 LAN ports can be used for
CSCP mixer remote control.
If the core is configured as a Master
Router, a standalone (outside of a
console) PC can be connected to any of
the 3 LAN ports for accessing H20; the
network administrator's user interface.
LEDs are also provided to show the status
of the primary and secondary DSP and
Router cards. Disk Activity indicates write
activity to the module's compact flash
card. Switch OK and Software OK show
the card processing status.
Reset & sync interface card
This module fits in the central, 5th card
slot of the Artemis Light processing core.
Three buttons can individually reset the
control, router and DSP cards within the
core. The bottom 'Reset Enable' button
is a safety precaution which must be held
whilst pressing any reset button.
4 x BNC connectors provide sync inputs,
allowing for redundancy and a range of
formats. Two inputs are for SD/HD video
sync signals, one for AES DARS and one
for TTL Wordclock.
RESET & SYNC INTERFACE CARD
CONTROL PROCESSOR MODULE
CALREC Putting Sound in the Picture
37
DSP
The primary, normally active DSP card
fits in slot 3, to the immediate left of the
primary Control Processor. The secondary,
hot-spare DSP card fits in slot 7, to the
immediate right of the secondary Control
Processor.
This audio signal processing card has
no front panel connections. All audio
and data is passed to / from the Master
Control and router cards via the core
backplane.
Bus Processor OK and Channel
Processor OK indicate processing status
within the module.
Router
Card slot 2 is for the primary / normally
active router module, slot 8 is for the
secondary / hot-spare router module.
The Artemis Light router card has 8 SFP
ports that can be fitted with copper or
fibre SFP's to allow connection of Hydra2
I/O boxes and connections to other
consoles or standalone Hydra2 router
cores.
A single RJ45 port labelled LAN allows
for 3rd party equipment supporting the
SW-P-08 or Ember protocols to interface
for remote control.
As well as the standard status LED's there
are front panel indicators to show the
active sync source and for activity on the
RJ45 and SFP ports.
Power supply
Card slots 1 & 8 are for PSU modules.
Both slots share the power load for the
whole core. One card is sufficient to
power a fully populated core, two are
fitted to provide redundancy. Each card
has an IEC AC mains input connector,
requiring 100–240V AC.
ROUTER MODULE
DSP MODULE
POWER SUPPLY MODULE
38 ARTEMIS Digital Broadcast Production Console
Processing Core – Light
OBSOLETE CONTROL
PROCESSOR MODULE
Cores made pre-2015 have a slightly taller
internal card slot. Pre-2015 cores cannot
be fitted with cards designed for the new
cores. Pre-2015 cores can be identified
by having a plain metal finish on the front
panel.
Standard status LEDs
• POK - Power OK, module is receiving
power.
• MA - Module Active. Indicates when
the module is actively in control.
• PRI - Indicates if the module is fitted in
a primary slot.
• RST - Illuminates when the module
receives a reset command.
• MOK - Module OK, indicates the
module is running, either actively or as
a hot-spare.
• NOK - Neighbour OK, indicates the
presence and status of the alternate
card of the same type. Neighbours
are primary / secondary counterparts
rather than physically adjacent cards.
• ST1 and ST2 are Calrec engineering
status LED's, the function of which
varies by card type and can be subject
to change with software versions.
Obsolete Control Processor
Two SFP slots at the top of the module
can be fitted with copper or fibre SFPs
and are the data connection point for
the control surface. The left hand
'MAC7' port of the left hand, primary
control processor card connects to the
primary surface switch within the control
surface. MAC7 on the secondary Control
processor card connects to the secondary
surface switch. MAC6 ports are only used
for very large console with a second pair
of surface switches fitted, or for sidecars
containing their own surface switches.
If the core is configured as a Master
Router, RJ45 port MAC5 should be
used to connect standalone (outside of
a console) PCs for accessing H20; the
network administrator user interface.
Ports MAC4 and MAC3 are for use by
Calrec engineers only.
As well as the standard status LEDs,
LEDs are provided to show activity on
the RJ45 and SFP ports. LEDs are also
provided to show the heartbeat status of
other cards within the core: D0 for the
primary DSP; D1 for the secondary DSP;
R0 for the primary router; and R1 for the
secondary router. The CF LED indicates
write activity to the module's compact
flash card and LO BAT is a low battery
warning for the module's BIOS. The
Master Control module's ST1 & ST2 LEDs
indicate the heartbeats from the modules
two processing cores.
PRE-2015 CORES
CALREC Putting Sound in the Picture
39
SIDE PROFILE VIEW - DIMENSIONS & AIR FLOW
SIDE PROFILE VIEW - DIMENSIONS WITH REAR SUPPORTS FITTED
OVERHEAD VIEW
478.50mm [18.84']
4U
177.00mm
[6.97']
• Air drawn in through front panel inlets. Air exits via top rear mounted fans
Long support position 645.64mm [25.42']
Short support position 591.64mm [23.29']
Depth excluding rear supports
478.50mm [18.84']
431.80mm [17.00']
482.80mm [19']
62mm
[2.44']
Airflow
The core is cooled by fan assisted
convection. Air is drawn in through inlets
on the front panels of the cards fitted in
the core. Air exits via 9 fans mounted
to the rear of the core, across the top.
The speed of each fan is monitored and
system status error reports are generated
for any failures. Air inlets and fans should
be left clear and unobstructed to ensure
air can flow through the card frame.
No clearance is required above or below
the core for cooling.
Support
The weight at the rear of the core should
be adequately supported to prevent
stress on the front racking angles. This is
particularly important when the units are
mounted in mobile installations. Calrec
will not accept liability for damage caused
by insufficient support..
The rear of the core can be supported by
side angles which are commonly available
from equipment bay suppliers for such
a purpose, or by the use of rear support
rails.
Calrec supply adjustable rear support rails
with each Artemis light core that can be
fitted during installation if required. The
support rails can be fitted in two different
positions depending on the depth of the
bay being used. Rear racking angles slide
over the support rails so the depth can be
adjusted to match the position of the rear
core fixings in the equipment bay.
Adjustable rear core fixing
42 ARTEMIS Digital Broadcast Production Console
Connection Information
SFP - OVERVIEW
The connections between control
surface and processing core, as well
as all Hydra2 network connections,
connections between I/O boxes
and routers, and router-to-router
connections between different cores,
are made via SFP modules (Small
Form-factor Pluggable).
SFPs can be provided for RJ45 copper
connections, as well as for singlemode or
multimode fibre on LC connectors. This
allows for each port’s connection type
to be chosen depending on the distance
of the run or to match the infrastructure
present. SFPs can easily be changed on
a port by port basis as and when required.
The correct quantity of SFPs are supplied
pre-fitted. The type of each connection
- copper, singlemode fibre or multimode
fibre, should be specified at the time of
order to ensure the correct SFP types
are supplied. Additional SFP modules
can be ordered if required. If a system is
to be connected to an existing Hydra2
network, please discuss this with your
Calrec project leader, sales person or
local distributor to ensure that SFPs are
provided and ports provisioned for the
additional router to router connections.
SFP MODULES
1
3
5
7
2
4
6
8
16
15
SFP
PORTS
2
INTERFACE
7 6
5 4 3 2 1 0
ADDRESS 1
1
0
0
1
R
HY
D
A
1
ROUTER CARD SFP ORIENTATION
FIXED FORMAT I/O BOX SFPS
• Router card shown with copper
SFPs fitted in ports 1-4,
singlemode fibre (button release)
in ports 5-8.
• I/O box shown with singlemode
fibre SFPs (button release) fitted.
• Both SFP types above
have a handle latching
mechanism, shown in the
locked position. The unit
on the left is a singlemode
duplex LC fibre module.
The unit on the right is a copper
RJ45 module.
STATUS
H2 I/F
RESET
WCLK OUT
1
2
HB1
SOFT
CTRL2
AUD2
PSU2
H_ACT
HB2
CTRL1
AUD1
PSU1
FAN1
FAN2
FAN 12V
MODULAR I/O BOX SFPS
• Modular I/O controller card SFPs
are both orientated the same way
around (Button release singlemode
fibre SFPs shown).
SFP slot orientation
SFP modules plug into front panel slots
on router and modular I/O controller
cards, and rear panel slots on fixed format
I/O boxes. The modules can be fitted or
removed whilst the system is powered and
without removing or opening any card or
box cases.
Note the orientation of the SFP modules,
as shown in the illustrations on this
page - modules fitted in even numbered
router ports (left hand column) are fitted
the opposite way around to those in the
odd numbered router ports (right hand
column). Likewise for fixed format I/O
boxes, the primary SFP module is the
opposite way around to the secondary
SFP module. The modules are orientated
so that the release catch for the RJ45 /
LC connector plugs once inserted are on
the outside edge.
For modular I/O box controller cards,
both SFP slots are orientated so that
the release catch on the cable / fibre
connector are on the right-hand side.
SFP latching and extraction
Calrec source SFP modules from various
manufacturers. All types used conform
to the same specification, however the
latching mechanism on them can vary
slightly.
The standard copper SFP, and some fibre
SFPs as shown in the photograph on the
previous page have latch / extraction
handles. On insertion, the handles should
be set against the outer edge (the same
side as the release catch on the RJ45 /
LC connector plug that fits into the SFP)
to lock it into place and prevent accidental
removal if cables are pulled.
To remove this style of SFP, remove the
cable / fibre and slide the handle (copper)
or lift the handle out (fibre) to the inside
edge position as shown in the diagram
below. The module can then be removed
by pulling on the handle.
CALREC Putting Sound in the Picture
43
Loose SFP storage
SFP modules are small, yet reasonably
expensive devices. When removing or
changing SFPs, take care to keep track of
them and store loose modules in a clean,
dry, and anti-static environment. Fibre
SFPs should always have a dust cover
fitted into their optical transceiver end
when no fibre is connected to them.
Calrec will not be liable for lost or missing
SFP modules, or damage due to poor
storage.
Other SFPs automatically latch into place
when they are inserted fully and have
a release button on their inside edge.
The fibre SFPs shown in the orientation
diagrams and below are of this type and
have blue release buttons. To remove,
depress the button using a small flat
blade screwdriver or similar tool. The SFP
module will then be free to be removed.
SFP slot covers
Dust covers should be fitted to all SFP
slots that do not have SFP modules
fitted in them in order to maintain plug-in
connection reliability.
1
2
1
2
SFPS WITH HANDLES - LATCHED
• Both SFPs shown are locked in
place - Latch / extraction handles
in outer position (or 'down' position
for fibre).
SFPS WITH HANDLES - UNLATCHED
• Both SFPs free to remove - Latch
/ extraction handles in inner (or
'Lifted' for fibre) position.
AUTO-LATCHING SFP
• Depress the release button
to remove.
SFP design varies depending on the
manufacturer, please ensure that SFPs
are correctly latched in place after fitting
them. In the event that a connection is
not automatically established after hot-
plugging an SFP, please reset the unit the
SFP is plugged in to.
44 ARTEMIS Digital Broadcast Production Console
Connection Information
Hydra 2 network connections and
control surface to processing core
connections made via copper SFP
modules require shielded F/UTP
Category 5e or Category 6 cables with
shielded RJ45 mating connectors.
Calrec do not supply these cables as it is
often preferable to terminate them after
they have been run through cable ducting
to avoid damaging the terminations, and to
be able to cut them to the precise length
required.
Shielded cables and connectors
Shielded cabling and connectors are
required in order to meet EMC (Electro-
magnetic compatibility) standards to
comply with the radiated emission limits
set in the standard EN55022, as well as
to guarantee performance in electrically
noisy environments.
F/UTP Cat5e/Cat6 cable has an overall
foil shield around the conductor cores.
Shielded RJ45 connector plugs have a
metallic shield around them which should
be clamped / bonded to the shield within
the cable. The shield on the connector
mates with the chassis of the RJ45
socket that it is plugged into, providing an
earth to the cable shield.
The method of attaching the connector
shield to the cable shield can vary. Please
refer to the connector manufacturer’s
information for further guidance.
COPPER SFP CONNECTIVITY
SHIELDED RJ45 CONNECTOR
Conductive connector mating
screen clamped / bonded to
cable shield
Maximum cable length
The maximum length of Cat5e/Cat6
cables is 90m / 295ft. This is the
absolute maximum and needs to include
any patch points and cables that may be
in the path. Hydra2 cable runs can NOT
be extended using Ethernet switches,
hubs or repeaters. If a run between
Hydra2 hardware exceeds the maximum
recommended distance for copper
cabling, fibre and optical SFPs should be
used instead.
Cable routing considerations
The layout and twist rate of the data cores
within Cat5e/Cat6 cables are integral
to their performance at high speed over
distance. Poor installation practise can
seriously impact upon this. The following
are general good rules of practise,
please refer to the cable manufacturer’s
information for comprehensive installation
rules.
When running Cat5e / Cat6 network
cabling, it is important to avoid kinking
the cable. Kinks can seriously impair
performance. Cable manufacturers
advise that kinked cables should be
discarded and replaced as the damage
caused cannot be addressed simply by
straightening the outer appearance.
Cables should not be bent in tight angles,
this too can seriously impair performance.
Please refer to the cable manufacturer’s
specification on minimum bend radii.
Excessive pulling force when routing
cables can deform the twist rate of the
cable cores, causing irreparable damage.
Cable manufacturers specify a maximum
pulling tension.
Cable-ties should not be over-tightened
as this also deforms the internal structure
of the cable. Cable ties should be tight
enough only to support the cable weight
Crimp points
Cable outer jacket
Strain relief
STRAIN RELIEVED RJ45 TERMINATION
but not so tight as to cause any visible
deformation to the cable’s outer jacket.
Large, heavy bundles of cables can
be difficult to support using cable-ties
without causing damage. 'Velcro' style
hook-and-loop cable straps can be a good
alternative to plastic cable-ties.
Whilst neatly bundled parallel cable runs
are tidy and aesthetically pleasing, they
decrease cross-talk immunity which
can impact on performance. Avoid neat
bundling of network cables over any kind
of distance - the majority of a cables
length is normally unseen, running under
floor or through ducting where they should
be loosely laid rather than neatly bundled.
Termination - strain relief
Poor termination and lack of strain relief
is one of the most common causes of
high speed network cable problems.
To properly strain relief the data cores,
the outer jacket of the cable should be
inserted into the RJ45 housing and held
in place once crimped by the strain-relief
point, as shown in the following diagram.
This also maintains the integrity of the
twist rate and shield into the termination,
• Note, this is a simplified
diagram that does not
include the shield.
CALREC Putting Sound in the Picture
45
Testing / certification
Calrec strongly recommend that all
Hydra2 network cabling is properly
tested or certified prior to on-site
commissioning of the system. Simple
test devices that only check the pin-out
of the terminations are not sufficient to
prove the performance and reliability of
high speed data cabling. Certification
level test equipment can give a simple
pass / fail response but in doing so will
test various important factors as well as
pin-out. Certification type tests include
determining cable length, measuring skew
(timing differences between pairings
due to variations in length caused by
intentional differences in twist rate),
measuring for loss, signal to noise ratio
and BERT error checking on data.
Cables that fail certification tests or fail
to perform, may appear to function fine
and therefore the full length of the cable
conforms to its’ intended specification.
Slide on outer boots offer additional
strain-relief protection but are not
sufficient on their own. In order to be able
to crimp the cable jacket inside the RJ45
and land the data cores on the terminals,
the amount that the jacket is stripped
back in relation to the cores needs to be
quite accurate. Cables with exposed data
cores should not be used as they will be
unreliable.
Termination - pin-out
Hydra2 network cables use the standard
gigabit Ethernet pin-out. Performance
relies on the positive and negative leg
of each signal pair using cores that are
twisted together. Calrec recommends that
'straight-through' or 'pin-for-pin' cables
are used. 'Cross-over' style cables can
be used, however they must be gigabit
standard cross-over. Older pin-outs,
designed for use with slower Ethernet
standards only use two of the four pairs,
even though all four pairs are terminated.
Cross-over variants of this style only cross
the pairs that are used (A & B). Gigabit
cross-over cables require that the blue (C)
pair is crossed with the brown (D) pair as
well as the orange (A) pair being crossed
with the blue (B) pair.
STANDARD HYDRA2 RJ45 PIN-OUT
Pin
Colour
Signal
1
Orange-White
A+
2
Orange
A -
3
Green-White
B+
4
Blue
C+
5
Blue-White
C -
6
Green
B -
7
Brown-White
D+
8
Brown
D -
1
8
Top
Front
1
8
RJ45 PIN NUMBERING
• For standard wiring, both
ends of the cable should be
terminated as above
in other applications, such as a PC LAN
connection where errors leading to retries
and therefore delays are acceptable and
often unnoticed.
Temporary / reusable cables
Cabling that is not part of a permanent
infrastructure, such as temporary runs
used for outside broadcasts should be
carefully coiled and uncoiled to avoid
kinking and they should be regularly
tested. Cables showing any sign of
damage should be replaced.
46 ARTEMIS Digital Broadcast Production Console
Connection Information
FIBRE SFP CONNECTIVITY
Optical SFP modules for fibre
connectivity can be used for console
to processing core, router to router,
and router to I/O connections.
Fibre connectivity is required when the
cable run between units exceeds the 90m
maximum permissible length for Cat5e/
Cat6 copper cabling. Fibre can also be
used for shorter runs if it is simply the
preferred medium.
Note that this section only concerns fibre
connections made via SFPs. Like all I/O
boxes, MADI units have pluggable SFPs
for their Hydra2 connections to routers,
but they also have fibre connectors that
pass the actual MADI audio format in and
out of the system. The MADI I/O format
fibre connectors are of a fixed type which
has no relation to SFP choice. Different
build types of MADI I/O box are available
to provide various types of MADI fibre
interface. Please refer to the Hydra2
installation manual for more details on
MADI I/O options.
Singlemode vs multimode
The core within multimode fibre is
relatively thick when compared to
singlemode. Light travels through
multimode fibre at multiple angles,
'bouncing' of the sides of the core as it
travels through it, taking multiple paths
or 'modes' of varying length from one
end to the other, resulting in pulses being
lengthened as they travel. Singlemode
fibre has a very fine core and light travels
in a single, direct path from one end to
the other without affecting pulse length.
The result is that singlemode fibre
has a higher bandwidth capacity and
importantly, low signal loss allowing much
greater distances to be achieved. Light
can be transmitted into multimode fibre
using LED’s or low powered lasers whilst
singlemode requires a higher powered
laser.
Calrec recommend the use of singlemode
fibre whenever possible in order to
maximise the flexibility in the location of
hardware and maintain uniformity across
the system by using a single type. If a
multimode infrastructure is in place, fibre
length, the number of inter-connects
and equipment location become more
important.
SFP modules are available for both
singlemode and multimode fibre types.
It is important to select the correct
SFP for the type of fibre being used in
the installation. If using a mixture of
singlemode and multimode fibre, it is
important to ensure the correct SFPs are
matched to the correct fibre type.
Identification
The release button / handles of fibre
SFPs are colour coded - Blue for
singlemode, Black for multimode. Blue
LC connectors, as shown below should be
used to terminate singlemode fibre, and
beige coloured ones for multimode.
Duplex Connectors / terminations
Standard Calrec fibre SFPs, multimode
and singlemode use duplex LC
connectors. The duplex termination
requires two fibres per connection, one
is a send path, the other is a receive path.
When terminating the fibre, the send from
DUPLEX LC FIBRES CORRECTLY TERMINATED A TO B & B TO A
one end should connect to the receive of
the other and therefore they are 'cross-
over', terminated A to B and B to A.
Single strand, bi-directional SFPs
To reduce the amount of fibre, Calrec
can supply singlemode SFPs that send
and receive over a single, or simplex LC
connector. In order to be able to pass
data in both directions over a single
strand, the light travelling in one direction
needs to be of a different wavelength to
the light travelling in the other direction.
Therefore, bi-directional SFPs come as
either type A, or type B, and they need
to be paired up - A fibre should connect
between a type A and a type B, and not
between two bi-directional SFPs of the
same type / wavelength. The units are
colour coded to aid identification between
type A's & type B's.
SFP / fibre specifications
Specifications are shown in the table
below. The maximum distances shown
assume a single point to point connection
with no intermediary interconnections.
Losses should be measured across the
total signal path including interconnects
- between points of SFP transceiver
connection. Losses need to be less than
the optical power budget of the SFP
transceivers being used.
SFP / FIBRE SPECIFICATIONS
BI-DIRECTIONAL LC FIBRE CORRECTLY CONNECTED, TYPE A TO TYPE B
SFP type
Connector
Power Budget
Fibre type
Max Distance
SX Multimode
LC Duplex
7.5dB
62.5/125µm
275m
50/125µm
550m
LX Singlemode
LC Duplex
8dB
8/125µm
10km
LX Singlemode bi-di
LC Simplex
11.5dB
9/125µm
10km
LH Singlemode
LC Duplex
23dB
8/125µm
70km
CALREC Putting Sound in the Picture
47
Testing / certification
Calrec strongly recommends that all fibres
are properly tested or certified prior to
on-site commissioning of the system.
A certain amount of signal loss occurs
over the length of a fibre path. If the total
loss of a path exceeds the optical power
budget of the SFPs in use, the system will
be unreliable.
Areas of loss
Signal loss occurs in various areas. Splice
loss occurs in terminations - at the point
where the fibre meets the connector.
Typically splice loss should be <0.3dB per
termination. Poor termination results in
higher loss.
Connector loss occurs at the point where
the connector meets the SFP / optical
transceiver, or another connector, such
as extension interconnects or patch-
points. Connector loss should typically be
<0.5dB per interconnect. Dust or other
contamination between interconnects
and scratches on the end surface contact
point of the fibre will substantially increase
the amount of loss. As such, dust
covers should always be fitted to optical
transceivers such as SFPs when no fibre
is connected and to fibre connectors that
are not landed.
As well as splice and connector loss, the
fibre itself has inherent loss over distance,
typically fibre loss will vary from 3.5dB per
km for multimode down to 0.4dB per km
for singlemode. Poor installation practise
and lack of care can damage the fibre and
result in substantially increased losses.
Fibre handling practise
It is important to follow the fibre
manufacturer's guidelines when handling
fibre and installing fibre runs. Some of the
main points of concern are:
• Minimum bend radii - fibre should not
be bent through too tight an angle.
Tight angles can cause significant
losses and permanent damage to the
fibre. Fibres may pass initial installation
testing but can fail at a later date due
to stresses on the core of the fibre
caused by tight bends.
• Twists, snags and kinks - Twists in fibre
runs add stresses to the core which
can cause damage over time. Avoid
snagging on other cables or conduit
which will cause excessive tensions
when pulling and can cause kinks and
excessive bends in the fibre. When
routing through angled conduit, provide
enough clearance around corners to
avoid the fibres being pulled sharply
around the inside of the angle.
• Pulling - observe the manufacturers
maximum pulling tension specification.
Use pulling tools and lubrication
where appropriate. Never pull on the
connector.
• Strain relief - fibres should be
adequately strain relieved to prevent
tension on terminations, however use of
plastic cable ties can crush the internal
construction of the cable. Hook-and-
loop 'Velcro' straps are harder to over-
tighten, offer more gentle support and
a greater surface area to dissipate the
pressure.
• Crushing - never place heavy items on
top of unprotected fibre.
Ruggedised fibre
For temporary / re-usable fibre runs , or
runs unprotected by conduit, fibre that
is likely to be exposed to the elements,
snagging or to being stood on, should
always be of a ruggedised / armoured
type to protect the internal construction of
the core.
WARNING
Never look into the end of an optical
transceiver or fibre when in use.
Laser radiation can be harmful to the
human eye and should be avoided.
Remember that when disconnecting
a fibre, the transmitting device at the
other end may still be active.
FIBRE - GENERAL RULES
Cleaning and preventative
maintenance
Contamination of transceiver and fibre
mating contact points causes signal loss
and can cause permanent damage by
scratching.
Dust covers should be fitted to all fibre
connectors and SFP optical transceivers
when they are not mated. It is also
important to ensure that dust covers
themselves are kept clean.
When handling fibres without dust covers,
do not allow the ends to come into contact
with any surface, including fingers.
Specialist materials should be used for
the cleaning of mating contact points to
avoid further contamination or scratching.
The following items are low cost and
readily available from camera shops and
laboratory suppliers:
• Canned compressed air - it is
important to use specialist filtered,
clean, dry air, free of contaminants and
moisture.
• Isopropyl alcohol. Use with cotton
swabs or lint-free wipes to ensure no
residue is left.
• Lint free wipes / long fibre, low ash
lens paper - needs to be free from
chemical additives. Ensure wipes
and swabs are stored in a clean
environment and are not reused.
48 ARTEMIS Digital Broadcast Production Console
Connection Information
Cleaning fibre optic cables and
connectors
There are multiple ways to clean fibre-
optic cables and connectors.
Included below are some helpful tips to
properly clean fibre optic cables.
• Do not allow the end of the fibre optic
cable to make contact with any surface
including fingers.
• Do not excessively bend the fibre
cable. Bending the cable may cause
internal breaks along the fibre resulting
in poor performance or instability.
• Optics and optic coatings are easily
chipped and/or scratched. Use of
finger cots or powder free surgical
gloves while handling fibre optic cables,
will help ensure cleanliness.
• Only fresh (dry) spectroscopic grade
Isopropyl Alcohol should be used as a
cleaning solvent.
• Ensure that the module power is
off and that other light sources are
disabled.
Cleaning procedure
1. Blow the fibre surface with a stream of
Clean Dry Air, this will dislodge larger
loose particles.
2. Place 1-3 drops of spectroscopic grade
Isopropyl Alcohol in the centre of a lens
tissue.
3. Hold the fibre by the connector or
cable, place the wet portion of the lens
tissue on the optical surface and slowly
drag it across.
4. Examine the surface of the fibre end
under high intensity light using a direct
magnifying inspection microscope
or an indirect video inspection tool if
available. If streaks or contaminants
still remain, repeat the process using a
fresh lens tissue.
5. Immediately install a protective cover
over the end of the cable to avoid re-
contamination or insert the fibre back
into the previously cleaned receptacle
for immediate use.
Additional notes
Do not tip the can of Clean Dry Air whilst
aerosol spraying as liquid may be released
contaminating the surface of the fibre.
Do not use lens paper dry as dry lens
paper is extremely abrasive.
Do not use Acetone as a cleaning solvent
on the fibre optical surfaces.
To ensure the purity of the Isopropyl
Alcohol, do not insert the lens tissue,
swabs, etc into the liquid, instead, drip the
liquid on to the material.
Cleaning optical transceivers
The best way to clean a transceiver port
is to remove particles using a stream of
Clean Dry Air.
Included below are some helpful tips to
properly clean fibre optic modules.
• Always handle optical SFP modules in
an ESD safe manner using the proper
safety precautions.
• Ensure that the module power is off
and handle the modules with care.
• Always use Clean Dry Air or an
approved canned compressed air
supply.
• Always hold the can of compressed air
upright. Tipping may release liquids
into the air stream.
• Do not touch the inner surfaces of the
module including the Optical Sub-
Assemblies (OSA), or insert any foreign
objects into the ports.
• Use of finger cots or powder free
surgical gloves are not required but
may be used for cleanliness.
Cleaning procedure
1. With the clean dry air, blow the inner
barrel of the Transmitter and Receiver
Optical Sub-Assemblies (OSA). This
will dislodge loose particles.
2. Examine the surface of the OSA lens
under high intensity light using the
inspection microscope. If contaminants
still remain, repeat the process.
Following these guidelines should
provide a successful installation and
ensure optimum reliability and system
performance.
For further information or advice please
feel free to contact Calrec.
CALREC Putting Sound in the Picture
49
To change the sync sources selected,
click on the desired source on the left, the
desired destination on the right and then
click 'Patch'.
The video inputs can be fed with analogue
or digital video in NTSC, PAL or a variety
of HD / tri-level formats. The correct
video format for each video input being
used needs to be specified from the Sync
page.
SYNCHRONISATION
Artemis processing cores have 4
BNC's to allow connection of external
sync. If no external sync is connected
and selected, the console will free-
run on its own synchronisation clock,
generated by the active router card.
General rules of good practise require
that all equipment connected to the audio
console's digital inputs and outputs are
all locked to the same referenced sync
source as the console to ensure clean
audio.
In systems with multiple Calrec
processing cores; i.e. where
more than one Apollo, Artemis or
standalone cores are connected
together, it is of paramount
importance that all connected
processing cores are locked to the
same referenced sync source.
One or more cores receiving a
sync signal that is not locked from
the same clock reference as other
cores can cause interruptions to
both audio and data carried by the
routers. This can lead to false error
warnings and IO boxes going offline.
Therefore it is essential to consider
a robust sync distribution design for
the facility and to ensure all points in
the chain are correctly configured to
lock to the appropriate input and no
elements such as sync regenerators
are changing the reference source or
free-running.
It is also recommended that backup sync
sources and paths are considered to
maintain full functionality in the event of
the loss of any part of the facilities' sync
distribution system.
External sync sources can be fed to
the BNC connectors at the top of the
processing core. Two inputs are available
for video formats, as well as an input for
TTL Wordclock and an input for AES3
digital audio reference.
Sync source selection
The sync sources to be used have to be
selected from the Console PC's Main
Application, >System Settings>Sync
page, or by the Hydra2 Organiser.
The main application must be in technician
mode (enter username and password on
the Tech page) to change sync settings.
Only one sync source is active and locked
to at any given time. Multiple sources
can be selected by priority to determine
the next choice to use in the event of the
active source failing.
The Sync page shows the available
sources on the left and the selected
sources on the right. The last of the
'selectable' sources is actually fixed as
Internal to ensure that console will run on
its own clock when no external sync is
present.
On boot up or reset, the console attempts
to lock to the first sync source in the
selection list. If it cannot lock to the first
choice, it will move down the list in order
until a source can be locked to.
The source currently locked to is displayed
on the screen. Any sync failures to the
local core will be reported by System
Status. If a failed sync input becomes
good, the console will NOT automatically
re-lock to it as any changeover in sync
could affect audio. S witching back to the
primary sync choice is done manually by
clicking 'Reset to 1st' on the sync page, or
automatically after the next boot / reset.
50 ARTEMIS Digital Broadcast Production Console
Connection Information
SURFACE TO CORE CONNECTION
A connection is required between the
Control Processors in the processing
core and the Surface Switches inside
the control surface.
These connections are via SFPs,
either fibre or copper, as requested at
order depending on the distances and
infrastructure involved.
Calrec do not provide these
interconnecting fibres / cables as
the length, type and quality will vary
depending on the specific requirements of
each installation.
Copper connections should be made
using screened Cat5e or Cat6 cable.
For more information on copper
connections, SFP's and fibres, please see
the Connection Types and Cat5e Cables
sections.
The illustrations to the right show the
location of the connections on the cores
and surface switches.
The two surface switches are located
inside the control surface, mounted to the
rear cover of the section containing the
IEC mains power inlets. These can be
accessed by removing the control surface
panels and up-stand meter panels in that
area of the console.
The two surface switches should be easily
identifiable on the rear cover. The left
hand unit, when viewed from the front is
the primary Surface Switch, the right hand
unit is the secondary Surface Switch.
In the processing core, the left hand
Control processor is the Primary, the right
hand is the secondary.
8U APOLLO & ARTEMIS SHINE / BEAM CORE TO CONSOLE CONNECTIONS
A connection should be fitted
between the Primary Surface Switch
on connector 'A' and the Primary
Control Processor's connector
'Surface 1'.
A backup connection should be
fitted between the Secondary
Surface Switch connector 'A' and
the Secondary Control Processor
connector 'Surface 1'.
It is important to ensure that these
connections are made correctly - primary
to primary, secondary to secondary and on
the correct connectors.
To Primary Surface Switch connector A
To Secondary Surface Switch connector A
To Primary Surface Switch connector A
To Secondary Surface Switch connector A
4U ARTEMIS LIGHT CORE TO CONSOLE CONNECTIONS
SURFACE SWITCH TO CORE CONNECTIONS
To Primary Control Processor Surface 1 connector
To Secondary Control Processor Surface 1 connector
Primary
Surface Switch
Secondary
Surface Switch
*Artemis Light Control
Processor port labelling
has changed—'Surface 1'
was previously 'MAC 7' and
'Surface 2' was previously
'MAC 6'
CALREC Putting Sound in the Picture
51
CONTROL SURFACE SIDECAR CONNECTION
The processing core supports an
additional connection for a second
control surface known as a sidecar.
A sidecar surface, unlike a surface
extension is fitted with its own pair of
surface switches and connects to the
'Surface 2' SFP ports on the Control
Processor cards in the processing
core, as shown in the adjacent diagram.
The primary surface switch needs to be
connected to the primary controller card,
and secondary switch to secondary card
to provide redundancy.
The Calrec Main Application >System
Settings>Surface layout page defines
the control surface panels that are fitted.
The layout shown on the 'Surface 1'
tab relates to the main control surface,
connected to the Control Processor
'Surface 1' ports. The layout shown on
the 'Surface 2' tab relates to a sidecar
surface connected to 'Surface 2'. The
surface layout numbers the POE switches
starting from #1 for both surface 1 and
surface 2. The surface layout page allows
for different console layouts to be created,
edited, saved and loaded onto the control
surface(s).
For systems that have temporary sidecars
it is advisable to have two surface layouts
saved, one with a sidecar / surface 2 and
one without. Loading a surface layout
with a surface 2 sidecar enables the
sidecar control panels. Loading a surface
layout without a surface 2 configuration
prevents error messages being generated
for panels that are not present when the
sidecar is removed or not powered, as
well as preventing paths being placed on
faders that are not currently present.
As with the main surface, the sidecar
can be supplied with copper or fibre
connections depending on the distance
required between the processing core and
the control surface.
Both control surfaces have full access to
the DSP within the processing core as
well as to all of the I/O that the processing
core has been given access to. To prevent
control conflicts, user splits can be put
in place between the two surfaces and
different monitoring outputs can be set up
for each one. Please refer to the console
operator manual for further information on
user splits and monitoring.
Both the main surface 1, and the sidecar
surface 2 can be physically split further
using extended control surface's if
required.
Extremely large control surface's would
require 2 pairs of surface switches fitting
in the single chassis surface in order to
be able to communicate with the high
number of control panels.
In such a case, the single chassis would
connect to both 'Surface 1' and 'Surface
2'. The surface layout for the single
control surface would be split across the
surface 1 and surface 2 screens. In such
a case, a separate sidecar cannot be
added, though surface extensions may be.
USB
YZ5716-2
Surface Switch
IP
PS
PR
PS1
PS2
PS3
PS4
PS5
PS6
PR1
PR2
- Input Power
- POE Switch
- Power & Reset
IP2
2
4
6
1
3
5
IP1
A
B
Serial number
USB
YZ5716-2
Surface Switch
IP
PS
PR
PS1
PS2
PS3
PS4
PS5
PS6
PR1
PR2
- Input Power
- POE Switch
- Power & Reset
IP2
2
4
6
1
3
5
IP1
A
B
Serial number
Sidecar / Remote Surface
AC in
AC in
USB
YZ5716-2
Surface Switch
IP
PS
PR
PS1
PS2
PS3
PS4
PS5
PS6
PR1
PR2
- Input Power
- POE Switch
- Power & Reset
IP2
2
4
6
1
3
5
IP1
A
B
Serial number
USB
YZ5716-2
Surface Switch
IP
PS
PR
PS1
PS2
PS3
PS4
PS5
PS6
PR1
PR2
- Input Power
- POE Switch
- Power & Reset
IP2
2
4
6
1
3
5
IP1
A
B
Serial number
CONTROL
ROUTER / EXPANDER
ENABLE
DSP
SYSTEM
RESETS
FAIL
GOOD
FANS
AES 3
VIDEO 2
VIDEO 1
WORD
CLOCK
SYNC INPUTS
DSP 1
PROCESSOR 1
PROCESSOR 2
DSP 2
PSU 1
PSU 2
CONTROL
EXPANSION 1
ROUTER 1
EXPANSION 2
ROUTER 2
POK
ST0
ST1
ST2
ST3
ST4
ST5
ST6
AC IN
USB
ST1
ST2
ST3
ST4
ST5
ST6
AC IN
USB
POK
ST0
ROUTER / EXPANDER
PSU
PSU
ROUTER / EXPANDER ROUTER / EXPANDER
DSP
DSP
ROUTER / EXPANDER
POK
MA
PRI
RST
MOK
NOK
ST1
ST2
POK
MA
PRI
RST
MOK
NOK
ST1
ST2
POK
MA
PRI
RST
MOK
NOK
ST1
ST2
POK
MA
PRI
RST
MOK
NOK
ST1
ST2
POK
MA
PRI
RST
MOK
NOK
ST1
ST2
POK
MA
PRI
RST
MOK
NOK
ST1
ST2
D1
D2
D3
D4
D5
D6
D7
D8
D1
D2
D3
D4
D5
D6
D7
D8
9
11
13
15
10
12
14
16
1
3
5
7
2
4
6
8
10
9
12
11
14
13
16
15
2
1
4
3
6
5
8
7
ETHERNET
LINKS
LINKS
9
11
13
15
10
12
14
16
1
3
5
7
2
4
6
8
10
9
12
11
14
13
16
15
2
1
4
3
6
5
8
7
ETHERNET
LINKS
LINKS
9
11
13
15
10
12
14
16
1
3
5
7
2
4
6
8
10
9
12
11
14
13
16
15
2
1
4
3
6
5
8
7
ETHERNET
LINKS
LINKS
9
11
13
15
10
12
14
16
1
3
5
7
2
4
6
8
10
9
12
11
14
13
16
15
2
1
4
3
6
5
8
7
ETHERNET
LINKS
LINKS
CONTROL PROCESSOR
MAC 6
MAC
4
MAC
3
MAC
5
USB
1
MOUSE
KBD
VGA
D1
D0
R1
R0
E1
E0
MA
POK
RST
PRI
NOK
MOK
ST2
ST1
LOW BATT
CF
USB
2
MAC 7
CONTROL PROCESSOR
MAC 6
MAC
4
MAC
3
MAC
5
USB
1
MOUSE
KBD
VGA
D1
D0
R1
R0
E1
E0
MA
POK
RST
PRI
NOK
MOK
ST2
ST1
LOW BATT
CF
USB
2
MAC 7
A
A
A
A
Primary
Secondary
Primary
Secondary
Main Control Surface
1
2
3
4
1
3
4
2
MAIN SURFACE / SURFACE 1 & SIDECAR / SURFACE 2 CONNECTIONS
52 ARTEMIS Digital Broadcast Production Console
Connection Information
EXTENDED CONTROL SURFACE CONNECTIONS
CONTROL SURFACE EXTENSION USED TO CREATE 'WRAP-AROUND' CONSOLE
USB
YZ5716-2
Surface Switch
IP
PS
PR
PS1
PS2
PS3
PS4
PS5
PS6
PR1
PR2
- Input Power
- POE Switch
- Power & Reset
IP2
2
4
6
1
3
5
IP1
A
B
Serial number
P1
P2
P3
P4
P5
P6
S1
S2
USB
YZ5706 - POE SWITCH
P
S
AP
SPR
RST
AP1
AP2
AP3
AP4
SPR1
SPR2
RST
RST
A
B
2
1
POWER
GOOD
A
B
AC IN 1
AC IN 2
P1
P2
P3
P4
P5
P6
S1
S2
Panel
Surface switch
Ancillary Power
Surface switch
Power & Reset
Reset
-
-
-
-
-
Serial number
USB
YZ5716-2
Surface Switch
IP
PS
PR
PS1
PS2
PS3
PS4
PS5
PS6
PR1
PR2
- Input Power
- POE Switch
- Power & Reset
IP2
2
4
6
1
3
5
IP1
A
B
Serial number
P1
P2
P3
P4
P5
P6
S1
S2
USB
YZ5706 - POE SWITCH
P
S
AP
SPR
RST
AP1
AP2
AP3
AP4
SPR1
SPR2
RST
RST
A
B
2
1
POWER
GOOD
A
B
AC IN 1
AC IN 2
P1
P2
P3
P4
P5
P6
S1
S2
Panel
Surface switch
Ancillary Power
Surface switch
Power & Reset
Reset
-
-
-
-
-
Serial number
P1
P2
P3
P4
P5
P6
S1
S2
USB
YZ5706 - POE SWITCH
P
S
AP
SPR
RST
AP1
AP2
AP3
AP4
SPR1
SPR2
RST
RST
A
B
2
1
POWER
GOOD
A
B
AC IN 1
AC IN 2
P1
P2
P3
P4
P5
P6
S1
S2
Panel
Surface switch
Ancillary Power
Surface switch
Power & Reset
Reset
-
-
-
-
-
Serial number
Main Control Surface
Sidecar / Remote Surface
AC in
AC in
See Category 5e Cable section for
further info. As these are copper only
connections, the cable distance between
surfaces is 90m [295 ft] maximum.
In addition to sidecars, console
chassis can also be split using
extended control surfaces.
This can be to allow multiple operators
the comfort of more space, to create a
'wrap around' surface for small rooms or
large consoles to bring faders closer, or to
provide control from a different location.
Unlike a sidecar, a control surface
extension is not fitted with its own surface
switches and therefore does not connect
directly to the processing core. Instead,
console extensions connect to the main
control surface via its' surface switches.
Multiple surface extensions can be added,
limited only by the maximum number
of POE's that can be connected to the
surface switches. Surface extensions can
also be used in conjunction with sidecar
surfaces.
Using surface extensions and / or
sidecars in conjunction with user splits
and multiple monitor or headphone
outputs, along with the huge resources
of both input channels and output
buses allows multiple operators to work
independently on a single core system.
Consoles built with the intention of
connecting to extensions will have RJ45s
mounted and labelled in the rear interface
for this purpose. A primary and secondary
data connection between the surface and
the extension are required. A third RJ45–
RJ45 connection, carrying the reset
lines is optional, depending on whether
the extension is fitted with its own reset
button or not.
Screened Cat5e cable should be used
to guarantee performance. These
connections use standard Ethernet pin-
outs and pairings. The reset cable, if used
needs to be a 'straight-through' pin out,
NOT a 'cross-over'.
SURFACE EXTENSION CONNECTIONS
CALREC Putting Sound in the Picture
53
AUDIO I/O CONNECTIONS
All audio inputs and outputs to / from
the console signal processing engine
are Hydra2 based.
Audio Formats
Hydra2 I/O units come in a variety of
formats and connector types including
MADI and SDI embedders / de-
embedders as well as standard AES
digital and analogue mic/line formats with
a variety of connector types. Please refer
to the Hydra2 installation manual for full
details on I/O.
Power
All Hydra2 I/O units are fitted with
dual power supplies & IEC mains input
connectors operating from 100-240VAC.
Both power inputs should be fed,
preferably from two separate AC sources
to provide full redundancy. IEC 'Y' cords
are supplied to allow both inputs to be fed
from a single cable source in the event
that this is all that is available, ensuring
both PSU's can always be fed.
ID configuration
Each I/O box in a system needs to be
given a unique ID, set by a DIP switch
accessible from the rear of a fixed format
box, or on the side of the controller card
within a modular I/O box.
Box ID's, as well as system IP addresses
are factory pre-configured and recorded
prior to despatch. When ordering
additional Hydra2 I/O, please discuss
with your sales person or Calrec project
engineer to select suitable ID's for the
system it is to be used with.
If fitting a replacement I/O box, settings
its ID to the same as the unit it is
replacing allows it to function as a drop in
replacement with existing user memories
and requiring no further configuration (as
long as the box types are the same).
Care should be taken when setting HID’s
to avoid accidentally duplicating the same
ID on more than one box. Duplicate box
ID’s can cause network conflicts. I/O
boxes should be disconnected from the
network before changing their HID, and
reset or power cycled once the DIP switch
is set to ensure the new HID is active
before reconnecting to the network.
Do not change I/O box IDs or add
extra I/O to the system unless you are
confident it will not cause a conflict on
the network.
Fixed format I/O box IDs
The 8 way DIP switch is set as an 8 bit
binary representation of the HID value
with the left hand switch used for the most
significant bit, and the right hand switch
for the least significant bit. A switch in the
down / off position represents a binary
0 and a switch set in the up / on position
representing a binary 1. Each switch /
binary bit equates to a decimal value,
starting at 1 for the least significant bit.
The remaining switches are double the
value of their less significant neighbour,
making the 8th / most significant bit
equate to a decimal value of 128.
All fixed format I/O box ID switches are
orientated the same way, though some
boxes, such as MADI units, use a different
style switch with more pronounced
labelling. Ignore any labels on the switch
itself and always refer to the Calrec
labelling on the surrounding panel which
will show the most significant bit switch on
the left and the binary 1 position as up.
Address 2
Some I/O boxes, such as MADI units
are fitted with 2 banks of DIP switches
- Address 1 and Address 2, to provide a
16 bit ID and therefore a greater range
of values. Please note that only ID
values between 0 and 255 are currently
supported. Any DIP switches labelled
Address 2 should all be set to the off
position.
Modular I/O box ID setting
The ID for modular I/O boxes is set by
a DIP switch on the controller card and
is only accessible by removing the card.
Please refer to the Hydra2 installation
manual and ensure ESD precautions are
observed before removing any modular
I/O box cards.
ID switches on modular I/O controller
cards are orientated differently. Ignore
any labelling on the switch itself and refer
to the Calrec labelling printed on the
circuit board around the switch to clarify
its’ orientation. When viewing the card
from the side, the most significant bit is on
the left and the least significant bit on the
right. Pulling a switch towards you sets it
as a binary 1, away from you as a binary 0.
1
7 6 5 4 3 2 1 0
ADDRESS
0
1
0
0
0
1
0
0
1
1
1
128 64
32
16
8
4
2
1
32
4
2
1
=
+
+
+
39
STANDARD SWITCH FOR HID SETTING
• The above diagram shows how
each switch relates to a decimal
value. The setting shown in
the example provides a decimal
HID value of 39
54 ARTEMIS Digital Broadcast Production Console
Connection Information
The following illustrations show the ID
switch on the modular I/O controller card
from the side and top views.
Again the decimal value of 39 is used for
the example.
Modular I/O card slots
Please note that changing the card type
fitted in a modular I/O box slot requires a
change to the network configuration. If
the order that cards are fitted in a modular
frame matters, please discuss this with
your Calrec project engineer prior to
delivery. If for any reason the card order
needs to be changed post delivery, please
contact our Customer Support team or
your local distributor for guidance. Cards
of the same type can be interchanged
with no configuration change being
required. Additional cards can be fitted
in previously empty slots without further
configuration.
Hydra2 connection
I/O boxes require a direct connection to a
front panel Hydra2 port on the main router
card, or the expansion router card if fitted.
Each I/O box has two Hydra2 ports to
provide redundancy. Port 1 should always
connect to a primary main or expansion
MODULAR I/O CONTROLLER - SIDE
0
1
2
3
4
5
6
7
ID BITS
Sw3
1
2
4
8
64 32 16
128
Front Panel
1
2
4
8
16 32 64 128
MODULAR I/O - VIEWED FROM TOP
Front Panel
router, port 2 to the secondary main or
expansion router located in the same core.
Like the Hydra2 ports on the router card,
Hydra2 connections on I/O boxes are
SFPs and therefore the connection type
required (copper / single mode fibre /
multimode fibre) needs to be specified at
the time of order.
Note, any fixed RJ45's on the rear of
Hydra2 I/O boxes are not functional,
if copper connections are required,
copper SFPs should be specified.
Please refer to the Hydra2 installation
manual and H20 user guide for more
comprehensive details on Hydra2 I/O
options and connectivity.
FIXED FORMAT (NON-MADI) HYDRA2 I/O, REAR INTERFACE
Connect from Primary Router / Expansion card
Connect from Secondary Router / Expansion card
*No Connection
*No Connection
CALREC Putting Sound in the Picture
55
MODULAR HYDRA2 I/O, CONTROLLER CARD FRONT INTERFACE
FIXED FORMAT MADI HYDRA2 I/O, REAR INTERFACE
Connect from Primary Router / Expansion card
Connect from Secondary Router / Expansion card
Connect from Primary Router / Expansion card
Connect from Secondary Router / Expansion card
CONTROL
ROUTER / EXPANDER
ENABLE
DSP
SYSTEM
RESETS
FAIL
GOOD
FANS
AES 3
VIDEO 2
VIDEO 1
WORD
CLOCK
SYNC INPUTS
DSP 1
PROCESSOR 1
PROCESSOR 2
DSP 2
PSU 1
PSU 2
CONTROL
EXPANSION 1
ROUTER 1
EXPANSION 2
ROUTER 2
POK
ST0
ST1
ST2
ST3
ST4
ST5
ST6
AC IN
USB
ST1
ST2
ST3
ST4
ST5
ST6
AC IN
USB
POK
ST0
ROUTER / EXPANDER
PSU
PSU
ROUTER / EXPANDER ROUTER / EXPANDER
DSP
DSP
ROUTER / EXPANDER
POK
MA
PRI
RST
MOK
NOK
ST1
ST2
POK
MA
PRI
RST
MOK
NOK
ST1
ST2
POK
MA
PRI
RST
MOK
NOK
ST1
ST2
POK
MA
PRI
RST
MOK
NOK
ST1
ST2
POK
MA
PRI
RST
MOK
NOK
ST1
ST2
POK
MA
PRI
RST
MOK
NOK
ST1
ST2
D1
D2
D3
D4
D5
D6
D7
D8
D1
D2
D3
D4
D5
D6
D7
D8
9
11
13
15
10
12
14
16
1
3
5
7
2
4
6
8
10
9
12
11
14
13
16
15
2
1
4
3
6
5
8
7
ETHERNET
LINKS
LINKS
9
11
13
15
10
12
14
16
1
3
5
7
2
4
6
8
10
9
12
11
14
13
16
15
2
1
4
3
6
5
8
7
ETHERNET
LINKS
LINKS
9
11
13
15
10
12
14
16
1
3
5
7
2
4
6
8
10
9
12
11
14
13
16
15
2
1
4
3
6
5
8
7
ETHERNET
LINKS
LINKS
9
11
13
15
10
12
14
16
1
3
5
7
2
4
6
8
10
9
12
11
14
13
16
15
2
1
4
3
6
5
8
7
ETHERNET
LINKS
LINKS
CONTROL PROCESSOR
MAC 6
MAC
4
MAC
3
MAC
5
USB
1
MOUSE
KBD
VGA
D1
D0
R1
R0
E1
E0
MA
POK
RST
PRI
NOK
MOK
ST2
ST1
LOW BATT
CF
USB
2
MAC 7
CONTROL PROCESSOR
MAC 6
MAC
4
MAC
3
MAC
5
USB
1
MOUSE
KBD
VGA
D1
D0
R1
R0
E1
E0
MA
POK
RST
PRI
NOK
MOK
ST2
ST1
LOW BATT
CF
USB
2
MAC 7
SHINE/BEAM - ROUTER/EXPANSION I/O PORTS
Primary I/O Ports
Secondary I/O Ports
LIGHT - ROUTER I/O PORTS
Primary I/O Ports
Secondary I/O Ports
56 ARTEMIS Digital Broadcast Production Console
Connection Information
GPIO in Apollo and Artemis systems
is a Hydra2 option. GPIO cards
provide logic inputs and outputs that
can be assigned to various functions
on the control surface; allowing
console functions to trigger external
devices such as fader starts for
playback devices and for external
devices to trigger console functions,
for example auto-fades controlled by
a video switcher.
If GPIO is required, please discuss this
with your sales person or Calrec project
engineer. Optional GPIO cards can be
fitted in modular Hydra2 I/O frames, or
any fixed format Hydra2 box with a height
of 2U or greater. Multiple boxes can be
fitted with GPIO cards to make up the
required quantity. The physical location
of I/O boxes within the installation should
be considered when choosing which to fit
with GPIO cards.
A fixed format I/O box fitted with a GPIO
card has two D25 connectors on the rear,
female for inputs, male for outputs. GPIO
cards for modular frames have a single
D50 connector on the front for both inputs
and outputs. Two versions of modular card
are available, one with 8 changeover relay
outputs and one with 16 normally open
relay closures.
GP inputs
Each GPIO card type has 8 opto-isolated
inputs allowing for remote triggering of
console functions. Applying DC or AC
voltage across the positive and negative
pins of an input will trigger it. A common
way to trigger a GP input is by providing
a dry closure from a relay with no voltage
on it. If using a dry closure, it should not
simply be wired across the +/- terminals
of the opto input - one half of the closure
should be connected to a ground on the
GPIO card, the other half of the closure to
an opto input, and the other input should
be linked in the connector hood to a GPIO
card +5V pin. This prevents potential
GPIO CONNECTIONS
problems in connecting power between
different manufacturers' hardware and is
shown in the example below.
GP INPUT WIRING EXAMPLE
0V
+IN
-IN
+5V
Trigger
GP Input
External
Closure
Calrec GPIO card
+5V
(Dry)
External wiring
GP outputs
The fixed format I/O box GPIO card,
and the WY5858 modular GPIO card
both have 8 changeover relays each with
access to the normally open, normally
closed and either common relay pins or
normally open/closed negative pins to
provide flexibility in use. If required, these
contacts can be used to switch audio.
If being used to trigger external
equipment expecting a ground, the relay
common should be connected to a ground
from the external equipment and either
the normally open or normally closed
contact used as the trigger line.
If a dry closure is required by the external
equipment, this can be achieved by wiring
one leg to either the normally open or
normally closed contact and the other leg
to the common or normally open/closed
negative contact.
Normally open (NO) contacts short to
the common or negative pin when the
relay is activated by the selected function.
Normally closed (NC) contacts are
shorted to common or negative when the
function is NOT active.
CHANGEOVER OUTPUT EXAMPLE #1
changeover relay
(shown inactive)
Calrec Fixed Format
GPIO card
External wiring
Com
NO
NC
changeover relay
(shown inactive)
Calrec modular
GPIO WY5858
NO-
NO+
NC+
NC-
Connect NC-
and NO- to
make common
CHANGEOVER OUTPUT EXAMPLE #2
Dry closure only outputs
The WY5859 version of modular I/O card
provides the same 8 inputs along with 16
dry closure only relay connections that
short when activated (NO+ & NO-).
Pin-outs for all GPIO card types are
shown the on following pages:
• Changeover relay shown wired to
provide a dry closure when activated.
For WY5859 treat NO- as common.
changeover relay
(shown inactive)
Calrec GPIO card
External wiring
Com
NO
NM
• Changeover relay shown wired to
provide a ground when activated.
The ground can come from a 0V pin
in the GPIO card connector itself
as long as the receiving equipment
has the same ground reference. For
WY5858 and WY5859 common
setup see above.
CALREC Putting Sound in the Picture
57
FIXED FORMAT GPIO CONNECTIONS - 8 IN, 8 OUT
ADDRESS
7 6 5 4 3 2 1 0
7 6 5 4 3 2 1 0
0
1
0
1
PORT 1
FIBRE
PORT 1
NOT USED
PORT 2
NOT USED
PORT 2
FIBRE
GP OUTPUTS 1-8
GP INPUTS 1-8
Function
Pin
Opto 1
+
1
-
14
Opto 2
+
15
-
3
Opto 3
+
4
-
17
Opto 4
+
18
-
6
Opto 5
+
7
-
20
Opto 6
+
21
-
9
Opto 7
+
10
-
23
Opto 8
+
24
-
12
+5V
2
5
8
11
Ground
16
19
22
25
13
25 Pin Male D-Type - Wiring side of connecting cable
15 16 17 18 19 20 21 22 23 24 25
14
10 11 12 13
9
8
7
6
5
4
3
2
1
Function
Pin
Relay 1
Common
1
Normally Open
14
Normally Made
2
Relay 2
Common
15
Normally Open
3
Normally Made
16
Relay 3
Common
4
Normally Open
17
Normally Made
5
Relay 4
Common
18
Normally Open
6
Normally Made
19
Relay 5
Common
7
Normally Open
20
Normally Made
8
Relay 6
Common
21
Normally Open
9
Normally Made
22
Relay 7
Common
10
Normally Open
23
Normally Made
11
Relay 8
Common
24
Normally Open
12
Normally Made
25
Ground
13
25 24 23 22 21 20 19 18 17 16 15 14
13 12 11 10 9
8
7
6
5
4
3
2
25 Pin Female D-Type - Wiring side of connecting cable
1
• Calrec connector is female,
requiring male terminated cable
• Calrec connector is male,
requiring female terminated
cable
58 ARTEMIS Digital Broadcast Production Console
Connection Information
WY5858 - MODULAR GPIO 8 IN + 8 OUT
Function
Pin
GPI 1
+
1
-
34
GPI 2
+
18
-
2
GPI 3
+
35
-
19
GPI 4
+
3
-
36
GPI 5
+
20
-
4
GPI 6
+
37
-
21
GPI 7
+
5
-
38
GPI 8
+
22
-
6
Supply
+5 V
17
Supply
0 V
50
50 Pin Male D-Type - Wiring side of connecting cable
50
34
18
33
17
1
STATUS
8 IN / 8 OUT
CHANGEOVER
GPIO
Function
Pin
GPI 1
+
1
-
34
GPI 2
+
18
-
2
GPI 3
+
35
-
19
GPI 4
+
3
-
36
GPI 5
+
20
-
4
GPI 6
+
37
-
21
GPI 7
+
5
-
38
GPI 8
+
22
-
6
Supply
+5V
17
Supply
0V
50
GPO 1
NO+
39
NO-
23
NC+
7
NC-
40
GPO 2
NO+
24
NO-
8
NC+
41
NC-
25
GPO 3
NO+
9
NO-
42
NC+
26
NC-
10
GPO 4
NO+
43
NO-
27
NC+
11
NC-
44
GPO 5
NO+
28
NO-
12
NC+
45
NC-
29
GPO 6
NO+
13
NO-
46
NC+
30
NC-
14
GPO 7
NO+
47
NO-
31
NC+
15
NC-
48
GPO 8
NO+
32
NO-
16
NC+
49
NC-
33
Normally Open
relay
Calrec GPIO card
NO+
NO-
Normally Closed
relay
Calrec GPIO card
NC+
NC-
• Closes when activated
• Opens when activated
CALREC Putting Sound in the Picture
59
Function
Pin
GPI 1
+
1
-
34
GPI 2
+
18
-
2
GPI 3
+
35
-
19
GPI 4
+
3
-
36
GPI 5
+
20
-
4
GPI 6
+
37
-
21
GPI 7
+
5
-
38
GPI 8
+
22
-
6
Supply
+5 V
17
Supply
0 V
50
50 Pin Male D-Type - Wiring side of connecting cable
50
34
18
33
17
1
WY5859 - MODULAR GPIO, 8 IN + 16 CLOSURE OUTPUT
Normally Open
relay
Calrec GPIO card
NO+
NO-
• Closes when activated
Function
Pin
GPI 1
+
1
-
34
GPI 2
+
18
-
2
GPI 3
+
35
-
19
GPI 4
+
3
-
36
GPI 5
+
20
-
4
GPI 6
+
37
-
21
GPI 7
+
5
-
38
GPI 8
+
22
-
6
Supply
+5V
17
Supply
0V
50
GPO 1
NO+
39
NO-
23
GPO 2
NO+
7
NO-
40
GPO 3
NO+
24
NO-
8
GPO 4
NO+
41
NO-
25
GPO 5
NO+
9
NO-
42
GPO 6
NO+
26
NO-
10
GPO 7
NO+
43
NO-
27
GPO 8
NO+
11
NO-
44
GPO 9
NO+
28
NO-
12
GPO 10
NO+
45
NO-
29
GPO 11
NO+
13
NO-
46
GPO 12
NO+
30
NO-
14
GPO 13
NO+
47
NO-
31
GPO 14
NO+
15
NO-
48
GPO 15
NO+
32
NO-
16
GPO 16
NO+
49
NO-
33
60 ARTEMIS Digital Broadcast Production Console
Connection Information
Router /
Processing
Core
Audio I/O
Audio I/O
Audio I/O
Audio I/O
Router /
Processing
Core
Audio I/O
Audio I/O
Audio I/O
Audio I/O
Router /
Processing
Core
Audio I/O
Audio I/O
Audio I/O
Audio I/O
Router /
Processing
Core
Audio I/O
Audio I/O
Audio I/O
Audio I/O
Router /
Processing
Core
Audio I/O
Audio I/O
Audio I/O
Audio I/O
Router /
Processing
Core
Audio I/O
Audio I/O
Audio I/O
Audio I/O
CONNECTING TO OTHER CONSOLES/ROUTERS
FIGURE 1 - CORRECT CONNECTION OF A THREE CONSOLE NETWORK
FIGURE 2 - INCORRECT CONNECTION OF A THREE CONSOLE NETWORK
Three router cores connected with no duplicate paths.
Incorrect connection! The additional link creates a duplicate path.
Multiple Apollo and Artemis consoles
can be connected together and to
standalone Hydra2 routers, allowing
them to share each other's I/O
resources. Before connecting a
console to an active Hydra2 network it
is essential to be aware of IP address
compatibility and of the Master Router
status.
A single, standalone console with its
processing core and connected I/O units
forms a basic Hydra2 network. All Hydra2
networks require one, and only one of
the processing cores to be configured as
the Master Router. Therefore, consoles
specified at order to be standalone
will have their processing cores pre-
configured as Master Routers. It is vital
that this is changed before connecting
to an active Hydra2 network. A console
specified to be part of a wider Hydra2
network will not function reliably until it
is connected to a network with a Master
Router, or has its own core changed to
become a Master. Please contact Calrec
support for guidance on configuring router
master / slave status.
Each processing core is configured with
an IP address range unique within the
network it is to be connected to. It is
important to ensure that the IP address
range does not conflict before connecting
to an existing network.
Processing cores connect together using
any of their primary main router I/O ports,
highlighted on the following page. These
core-to-core connections should NOT be
made via expansion slot ports.
To provide redundancy, for each primary
router to router link, there should also be a
(normally inactive) link fitted between the
secondary router cards in the same cores.
When multiple cores are networked, it
is essential that they are all receiving
and are locked to the same derived
sync reference.
Each Hydra2 link can carry 512 channels
of audio in each direction simultaneously.
From software version 1.10, bandwidth
between cores can be increased in
multiples of 512 audio channels by adding
additional links to form trunks.
Trunk links should only be fitted if
they have been configured. Please
contact Calrec Customer Support or your
local representative for guidance on trunk
link configuration.
It is important that there is only one path
(not counting dedicated secondaries
and configured trunks) between any two
points on the network. It is important to
note that the path between I/O port and
console router may pass through other
routers. Figure 2 shows an incorrectly
connected network - the addition of a
third router to router link creates duplicate
paths. This will cause network collisions
as data can take two paths between any
two routers - one path is direct, the other
is via the third router. Removing any one
of the three router to router links corrects
this, effectively changing the topology to
match that shown in Figure 1.
Note, it is important to ensure that
when Hydra2 routers are networked
together, they are on separate VLANs.
CALREC Putting Sound in the Picture
61
For large systems, network topology
should be considered to manage
bandwidth. Using a processing core
as a central point to connect others,
rather than daisy-chaining them together
minimises the number of cores a signal
has to pass through to get between I/O
and console, optimising the available
bandwidth on each router to router link.
From software version 1.16 onwards
Auto Promote can be used to specify
which routers in a Hydra2 network can
automatically take over the master router
status in the very unlikely event of a
master router failure. Please contact
Customer Support for guidance on
configuring auto-promoting routers. See
the Master Router section of the Hydra2
installation manual for more information.
Please refer to the Hydra2
installation manual and H20
user guide for more information
regarding Hydra2 and I/O.
MAIN ROUTER PORTS AVAILABLE FOR ROUTER TO ROUTER CONNECTIONS
• Standard 8U processing core
• 4U Artemis Light core
Primary Main Router Ports
Secondary Main Router Ports
62 ARTEMIS Digital Broadcast Production Console
Connection Information
SURFACE REAR CONNECTOR PIN-OUTS
Analog input
Pin
1 Left
+
1
-
14
Ground
2
1 Right
+
15
-
3
Ground
16
2 Left
+
18
-
6
Ground
8
2 Right
+
7
-
20
Ground
22
25 Pin Male D-Type - Wiring side of connecting cable
15 16 17 18 19 20 21 22 23 24 25
14
10 11 12 13
9
8
7
6
5
4
3
2
1
3 Left
+
21
-
9
Ground
8
3 Right
+
24
-
12
Ground
22
MOVING COIL METER INPUTS
All audio is processed within the
core, the system does not pass audio
to or from the control surface on its
own. Calrec TFT and LED metering
in the control surface functions on
proprietary meter data which is not
decoded for listening and cannot
be used by 3rd party or ancillary
hardware.
Ancillary audio items such as moving
coil meters*, 3rd party meters such as
DK or RTW, headphones, talkback mics,
optional loudspeaker panels etc all require
an audio connection to the rear interface
panel of the control surface if they are to
be used.
If these items are to be fed directly from
console I/O, they should be provisioned
for in the quantity of Hydra2 I/O ordered.
Loudspeaker and some moving coil meter
panels are fitted with DIP switches that
can disable inputs and set levels. Please
refer to the Panel Options section of this
document for more detail on each panel
type.
• All D-type audio connectors on the
interface panel are 25 pin female,
requiring male terminated cabling.
Analogue Inputs
Pins
Left 1
+
1
-
14
Ground
2
Right 1
+
15
-
3
Ground
4
Left 2
+
7
-
20
Ground
22
Right 2
+
21
-
9
Ground
23
Balanced Digital Inputs
Pins
AES 1
+
18
-
6
Ground
5
AES 2
+
24
-
12
Ground
25
Unbalanced Digital
Inputs
Pins
AES 1
Signal
4 + 18
Ground
5 + 6
AES 2
Signal
10 + 24
Ground
11 + 12
Moving coil meters*
Important notes on moving coil meter
wiring:
• If feeding unbalanced AES digital,
BOTH signal pins and BOTH
ground pins shown for each leg
need to be connected.
• Input 2 not used for twin single
needle VU meter, or single dual
needle meter panels.
• Analogue and digital inputs
are both active, not switched.
Therefore only one format should
be fed to the meter at any given
time.
• Refer to Panel Options section for
DIP switch setup information about
moving coil meters.
* High quality moving coil meters are no longer being manufactured. With a lack of supply, Calrec has regretfully withdrawn them
from the product range. Users who prefer this style of meter should request one or two RTW TM7 meters are fitted in the
up-stand reset panel, specifying that moving coil emulation software is enabled. This package provides accurate VU and PPM
response with appropriate scaling on a clear, wide viewing-angle display, using graphics and sizing that compares well with true
mechanical versions.
CALREC Putting Sound in the Picture
63
All RTW meters have 8 analogue inputs
as well as digital I/O.
RTW METER ANALOGUE INPUTS
Analogue Inputs
Pins
1
+
24
-
12
Ground
25
2
+
10
-
23
Ground
11
3
+
21
-
9
Ground
22
4
+
7
-
20
Ground
8
5
+
18
-
6
Ground
19
6
+
4
-
17
Ground
5
7
+
15
-
3
Ground
16
8
+
1
-
14
Ground
2
RTW meters
RTW meters can be supplied with
either balanced or unbalanced AES I/O.
Unbalanced versions are wired out to
BNC connectors on the rear interface.
Balanced versions are wired to a D25
connector pinned out as below:
RTW METER DIGITAL I/O
Digital Inputs
Pins
1
+
24
-
12
Ground
25
2
+
10
-
23
Ground
11
3
+
21
-
9
Ground
22
4
+
7
-
20
Ground
8
Digital Outputs
Pins
1
+
18
-
6
Ground
19
2
+
4
-
17
Ground
5
3
+
15
-
3
Ground
16
4
+
1
-
14
Ground
2
64 ARTEMIS Digital Broadcast Production Console
Connection Information
BALANCED AES ONLY DK INPUTS
Input
Pins
1
+
1
-
14
Ground
2
2
+
15
-
3
Ground
16
3
+
4
-
17
Ground
5
4
+
18
-
6
Ground
19
5
+
7
-
20
Ground
8
6
+
21
-
9
Ground
22
7
+
10
-
23
Ground
11
8
+
24
-
12
Ground
25
DK meters
DK meters can be fitted with up to 4 input
cards. Card types available from Calrec
are:
• Unbalanced digital only, providing 4
AES3id inputs per card, wired out to
BNC connectors on the console's rear
interface.
• Balanced digital only, providing 4
AES inputs per card, wired to female
D25 connectors on the console's rear
interface
• Unbalanced digital and balanced
analogue mixed, providing 2 analogue
inputs and 1 AES3id input per card.
Analogue inputs are wired to female
D25s, digital to BNC's, both on the
console rear interface.
• Balanced digital and balanced
analogue mixed, providing 2 analogue
inputs and one AES input per card,
wired to female D25 connectors on the
console's rear interface.
• Analogue only, providing 8 balanced
analogue inputs per card, wired to a
female D25 connector on the rear
console's interface.
The input card types required affect the
internal wiring of the control surface and
should be specified at the time of order.
MIXED AES & ANALOGUE DK INPUTS
Input
Pins
AES 1 (3)*
+
1
-
14
Ground
2
Analogue
1 (3) L
+
4
-
17
Ground
5
Analogue
1 (3) R
+
18
-
6
Ground
19
AES 2 (4)*
+
7
-
20
Ground
8
Analogue
2 (4) L
+
10
-
23
Ground
11
Analogue
2 (4) R
+
24
-
12
Ground
25
• Quantity of inputs available
dependant on the number of input
cards ordered.
• If more than two cards ordered, an
additional D25 connector is fitted in
the rear interface for inputs above
#8, pinned out the same as inputs
1-8.
• Quantity of inputs available
dependant on the number of input
cards ordered.
• If unbalanced digital inputs are
specified for this card type, only
the analogue inputs are on D25s,
the digital inputs are on BNC
connectors.
CALREC Putting Sound in the Picture
65
HEADPHONE INPUTS
Input
Pins
1 Left
+
1
-
14
Ground
2
1 Right
+
15
-
3
Ground
16
2 Left
+
18
-
6
Ground
19
2 Right
+
7
-
20
Ground
8
3 Left
+
21
-
9
Ground
22
3 Right
+
24
-
12
Ground
25
BALANCED ANALOGUE ONLY DK
INPUTS
Input
Pins
1
+
1
-
14
Ground
2
2
+
15
-
3
Ground
16
3
+
4
-
17
Ground
5
4
+
18
-
6
Ground
19
5
+
7
-
20
Ground
8
6
+
21
-
9
Ground
22
7
+
10
-
23
Ground
11
8
+
24
-
12
Ground
25
Headphone sockets
The headphone driver unit in the control
surface has capacity for 3 stereo
balanced analogue inputs. The actual
quantity in use is dependent on the
number of headphone jack sockets fitted
/ requested at order.
Loudspeaker panels
Each loudspeaker panel fitted has 4
stereo balanced analogue inputs.
LOUD SPEAKER INPUTS
Input
Pins
1 Left
+
1
-
14
Ground
3
1 Right
+
2
-
15
Ground
3
2 Left
+
16
-
4
Ground
18
2 Right
+
17
-
5
Ground
18
3 Left
+
6
-
19
Ground
8
3 Right
+
7
-
20
Ground
8
4 Left
+
21
-
9
Ground
23
4 Right
+
22
-
10
Ground
23
Logic
Ext Cut
11
Ext Dim
24
Ground
13
• Quantity of inputs available
dependant on the number of input
cards ordered.
• Each analogue only input card has
a female D25 connector on the
console rear interface, pinned out
as above.
• Refer to the panel options section
for LS panel DIP switch input
enabling information.
68 ARTEMIS Digital Broadcast Production Console
External Control
The Hydra2 router allows for 1-to-n
source to destination routing of Hydra
inputs to Hydra outputs, without
using console DSP, or control surface
space. Control over input to output
cross-point routing can be carried out
from a console PC, a standalone PC
running the Hydra2 Organiser, or via
3rd party controllers supporting the
SW-P-08 protocol.
As well as physical Hydra2 I/O ports, the
H2O application and SW-P-08 controllers
also have access to Hydra Patchbays,
providing access to route console DSP
outputs and the ability to change sources
feeding console inputs.
SW-P-08 is a well proven communications
protocol with a very wide uptake by
router and controller manufacturers,
allowing their equipment to control, or to
be controlled by, other manufacturers'
equipment. Although in widespread
use, there is no official standard and
there can be slight variations in different
manufacturers' interpretation. As such,
where possible, Calrec prefer to test
communications with specific systems
before they are used for the first time,
allowing for software changes to be made
if required.
The following 3rd party SW-P-08 control
systems have so far been factory proven
by Calrec:
• L-S-B VSM
• Colledia BNCS
• Grass Valley Jupiter
• Evertz
• NVision
• Axon Cortex
• Harris Edge
Please refer to the relevant
manufacturer’s guidance for specific
information relating to their products.
Connection and redundancy
SW-P-08 controllers connect to the
front panel RJ45, labelled 'Ethernet',
on the Main primary router card (slot 2
of the processing core). Cards fitted in
expansion router slots do not support this
connection.
In multi-console / multi-core networked
systems, the connection should be made
to the Router card in the core configured
as the Master. Slaved router cores do not
support SW-P-08 connections. An SW-
P-08 connection made to the network's
Master Router can be given access to all
of the I/O and Hydra Patchbays on the
network, irrespective of which core the
I/O connects to directly, or which console
the Hydra Patchbays are configured for.
In the event of a router failure, the
secondary router card will take over and
continue SW-P-08 communications via
the connection made to the primary card's
front panel. If supported by the 3rd party
controller, a secondary connection can
also be made to the secondary router
card in the same core, providing additional
redundancy against cable, port, and
external third party switch / controller
failure.
If required, multiple SW-P-08 and also
EMBER controllers can be connected
simultaneously to the same RJ45 via an
external Ethernet switch / hub.
The router card's front panel Ethernet
connector uses a standard Ethernet
pin-out and passes data via TCP/IP.
Screened Cat5e cabling should be used
to ensure performance in electrically noisy
environments.
For 3rd party controllers that pass SW-
P-08 data over RS232/RS422, serial to
TCP/IP conversion is required. Convertor
units, such as the Perle IOLAN can be
supplied by Calrec.
SW-P-08 ROUTER REMOTE CONTROL
Connection configuration
The 3rd party controller (or the serial to
TCP/IP convertor if used) will need to
be configured to connect using the IP
address of the Calrec Master Router card
(and the secondary if a backup connection
is being made).
In addition to the IP address, the system
will need to be configured to use TCP
socket port 61000.
The default IP addresses for router cards
are - xxx.yyy.5.0 for a primary and xxx.
yyy.6.0 for a secondary, xxx.yyy is different
for each processing core and can be
confirmed using the Calrec Program
Updater application. If the default IP
addresses are unsatisfactory, Calrec
routers can be configured with alternative
IP addresses of choice. Configuring
alternative IP addresses should only
be done by, or under the guidance of a
Calrec engineer. Please contact your
sales representative, assigned project
leader or customer support to discuss any
alternative addressing requirements.
Note, Calrec default IP addresses are
defined by the core and slot the cards are
fitted in. Alternate, aliased IP addresses
are configured on the cards themselves,
and will therefore follow the card if it is
moved to a different slot or core.
SW-P-08 I/O mapping configuration
Physical I/O and Hydra Patchbays
that are to be accessible to 3rd party
controllers need to be given SW-P-
08 source / destination values which
correspond to values configured in the
3rd party controller. SW-P-08 values
can be manually typed for each input
source / output destination, or they can
be imported (and exported) in the form of
a CSV file.
SW-P-08 mapping requires the use of the
Calrec H2O GUI, please refer to the H2O
user guide for more details.
CALREC Putting Sound in the Picture
69
EMBER REMOTE CONTROL
The EMBER protocol is a
sophisticated data exchange
mechanism that has potential for
controlling many functions across
varied equipment types.
EMBER control has been incorporated
into Calrec’s Apollo, Artemis and Hydra2
range to allow various remote control
functionality, both over mixing consoles,
and the wider Hydra2 network.
Currently, Calrec have tested, and have
users on-air with the following EMBER
controllers:
• L-S-B VSM
• Colledia BNCS
Please refer to the relevant
manufacturer’s guidance for specific
information relating to their products.
Currently, EMBER has the ability to control
the following features when connected to
a Calrec Apollo/Artemis/Hydra2 network:
• Loading of shows and user memories
onto control surfaces.
• Loading / removing alias files used
by consoles, instructing them to use
different pre-defined sets of I/O ports.
• Please refer to the console operator
manual for more information on the use
of alias files.
• Input port settings - mic input gain, mic
input phantom power switching and
SRC switching on digital inputs.
• EMBER controllers can view and edit
the H20 based Hydra2 I/O box and
port labels.
• Inserting SMPTE2020 metadata
into Hydra2 SDI embedder outputs -
Metadata sets can be uploaded and
edited using the H20 application.
EMBER controllers can select any
of the available metadata sets for
insertion to, or removal from any of the
SDI embedder outputs on the network.
• EMBER controllers can selectively
mute any of the audio channels within
the SDI outputs of Hydra2 embedders.
Connection and redundancy
EMBER clients connect to the front
panel RJ45, labelled 'Ethernet', on
the Main primary router card (slot 2 of
the processing core). Cards fitted in
expansion router slots do not support this
connection.
In multi-console / multi-core networked
systems, the connection should be made
to the Router card in the core configured
as the Master. Slaved router cores do not
support EMBER connections. An EMBER
connection made to the network's Master
Router has access to all of the I/O and
mixing consoles on the Hydra2 network.
In the event of a router failure, the
secondary router card will take over and
continue EMBER communications via the
connection made to the primary card's
front panel. If supported by the 3rd party
controller, a secondary connection can
also be made to the secondary router
card in the same core, providing additional
redundancy against cable, port, and
external third party switch / controller
failure.
If required, other controllers can be
connected to the same RJ45 on the
router at the same time, by using an
external Ethernet switch / hub.
The router card's front panel Ethernet
connector uses a standard Ethernet
pin-out and passes data via TCP/IP.
Screened Cat5e cabling should be used
to ensure performance in electrically noisy
environments.
For 3rd party controllers that pass
EMBER data over RS232/RS422,
serial to TCP/IP conversion is required.
Convertor units, such as the Perle IOLAN
can be supplied by Calrec.
Connection configuration
The 3rd party EMBER controller will need
to be configured to connect using the
IP address of the Calrec Master Router
card (and the secondary if a backup
connection is being made).
In addition to the IP address, the system
will need to be configured to use TCP
socket port 62000.
The default IP addresses for router cards
are - xxx.yyy.5.0 for a primary and xxx.
yyy.6.0 for a secondary, xxx.yyy is different
for each processing core and can be
confirmed using the Calrec Program
Updater application. If the default IP
addresses are unsatisfactory, Calrec
routers can be configured with alternative
IP addresses of choice. Configuring
alternative IP addresses should only
be done by, or under the guidance of a
Calrec engineer. Please contact your
sales representative, assigned project
leader or customer support to discuss any
alternative addressing requirements.
Note, Calrec default IP addresses are
defined by the core and slot the cards are
fitted in. Alternate, aliased IP addresses
are configured on the cards themselves,
and will therefore follow the card if it is
moved to a different slot or core.
Control configuration and enabling
With a valid connection made, all
parameters accessible to EMBER are
made available. No further Calrec
configuration is required.
Mixing console operators can enable or
disable EMBER controllers from being
able to change their control surface show
/ user memory and I/O aliasing from the
Calrec Main Application's
>System Settings>Ext Control page.
70 ARTEMIS Digital Broadcast Production Console
External Control
CALREC SERIAL CONTROL PROTOCOL
The Calrec Serial Control Protocol,
CSCP, allows for remote control over
mixing console operational functions
by 3rd party systems such as video
switchers and production automation
systems.
Several broadcast equipment
manufacturers provide serial control
protocols that are compatible with CSCP.
The following systems are currently in
use around the world, actively controlling
Calrec audio mixing consoles for live
on-air applications:
• Ross Overdrive (Automated Production
Control system) & Ross video
switchers.
• Sony ELC.
• Snell Kahuna.
• Mosart.
• Grass Valley Ignite.
• L-S-B VSM.
Please refer to the manufacturer's
guidance for specific information relating
to their products.
CSCP versions
Additional controls have been made
accessible via CSCP since it was first
introduced, requiring new commands be
added to the protocol, and new versions
released. If 3rd party equipment receives
CSCP data it does not understand, it
should simply ignore it, however Calrec
cannot guarantee the operation of third
parties, and as such makes all CSCP
versions available for use on Apollo and
Artemis consoles.
Faders controlled by CSCP
Third party systems with a CSCP
connection to an Apollo or Artemis
console have access to control and
read back the status of 192 path faders.
Starting with the lowest numbered fader
(usually #1) on layer 1A, up to the highest
consecutively numbered fader, followed by
the same fader numbers on layer 1B, then
layer 2A, 2B, 3A, 3B etc. up to a total of
192 faders.
If required, the faders exposed to CSCP
control can be zoned, preventing remote
control over the entire surface width
by intentionally inserting gaps in fader
numbering. The 8 faders within a panel
are always consecutively numbered, but
they do not need to be so between panels.
Under technician level access to the
console's Main Application, the surface
layout page allows a number to be chosen
for the first fader on each panel. If for
example, the first panel is numbered 1-8,
but the second panel, instead of starting
with fader 9, is actually set to start at 10
(or any higher number), CSCP would only
have access to faders on the first panel,
ensuring faders in the remaining surface
area cannot be remotely controlled by
third parties. Using this example of
exposing only one fader panel to CSCP
control, all layers of that panel can be
accessed by the protocol (12 layers x 2
A/B sub-layers x 8 faders on a single
panel = 192 faders total). It is also worth
noting, that the lowest numbered faders in
a control surface do not have to physically
be at the left hand side.
Controls available via CSCP
CSCP V1.0 allows third party controllers:
• Control over and read back of the
position of 192 path faders.
• Read back of the 192 faders' path /
port labels.
• Control over and read back of the Cut /
On status for the same 192 faders.
• Control over and read back of the PFL
status for the same 192 faders.
• Control over and read back of Main
output bus levels and PFL status.
• Read back of the console's name / ID.
CSCP V2.0 provides the same
functionality as V1.0 with the following
additional features being made available:
• Control over and status read back of
the same 192 faders' routing to the
first 20 Auxiliary output buses.
• Control over and read back of the first
20 Aux bus output levels.
• Read back of the path types allocated
to the 192 faders.
CSCP V2.1 provides all the functionality
of V1.0 & V2.0 along with the following
additional features:
• Control and status read back over the
192 faders' routing to Main output
buses.
• Control and status read back over Left
to Both & Right to Both input controls
for stereo paths on the same 192
faders.
Connection
Although the protocol is based on and
passes serial data, the Calrec connection
is made via TCP/IP. If interfacing to third
party systems which only support point
to point RS232/422 serial connections,
TCP/IP conversion will be required.
For this purpose, Calrec support the use
of, and can supply Perle IOLAN units.
The CSCP connection should be made
to either of the three ethernet ports
(the MAC5 ports for the 8U or older 4U
control processor models) on the front
panel of the primary Control Processor
fitted in the core associated with the
console being controlled (Unlike H2O /
SW-P-08 / EMBER connections which
are always made to the Hydra2 network's
Master Router core). If multiple consoles
are to be controlled, each will require its
own CSCP connection.
CALREC Putting Sound in the Picture
71
To enhance redundancy, and minimise
the amount of change-over required in
the event of a failure, both the primary
and secondary Calrec controller cards
can communicate over each other's front
panel ports - in the event of a primary
controller card failing, the secondary
would automatically become active, but
would still send and receive CSCP data
over the connection made to the primary
card.
Secondary connections
Third party CSCP controllers that support
redundant secondary connections should
be connected to one of the ethernet ports
(MAC5 port for the 8U or older 4U control
processor design) on both the primary
and secondary Calrec controller cards to
provide complete redundancy, protecting
against cable / port failure and card
removal. If required, this connection can
be via an Ethernet switch, e.g. to allow a
single RJ45 port on a 3rd party controller
to connect to both primary and secondary
Calrec ports.
Multiple consoles
If CSCP connections from multiple Calrec
consoles are to be networked together,
the consoles need to connect via a layer3
(IP) Ethernet switch in order to prevent
MAC address conflicts.
Connecting via corporate LAN
DHCP servers run on the Calrec Control
Processor cards to allow easy connection
of a PC from configuration purposes
or to access H2O. The PC should be
connected to one of the Ethernet ports
on the front of the control processor (or
via the MAC5 port for the 8U or older 4U
design). If a CSCP or other connection is
to be made to these ports via a corporate
LAN, it is important that the Calrec DHCP
servers are disabled and the connections
are manually configured as appropriate.
Configuration
Please discuss your installation
requirements with your Calrec sales
representative or distributor prior to
delivery. CSCP connections should be
configured and tested by, or under the
guidance of a Calrec approved engineer.
The following points should be noted
when communicating your requirements:
The default Calrec IP addresses are xxx.
yyy.1.0 for the primary, and xxx.yyy.2.0
for the secondary Control Processor
cards. xxx.yyy is unique for each Apollo /
Artemis / Standalone Router processing
core and can be confirmed by running
the Program Updater GUI. If the default
addresses are not suitable, please supply
alternative IP addresses and a subnet
mask which can be configured pre-
delivery or during commissioning.
If required, the Calrec system can be
configured to connect via an IP gateway.
In addition to connecting by IP address,
both the Calrec system and the 3rd party
require configuring to use the same TCP
socket port. The default TCP socket
port for CSCP is 49200.
User & boot up enable / disable
Once configured, CSCP can be enabled
or disabled from the console's Main
Application,
>System Settings>Ext Control screen.
Being part of the System Settings,
the enabled / disabled selection is
automatically saved for recall after a reset
or power cycle. System settings are not
saved as part of the show or user memory
and will therefore not change when
different shows / memories are loaded
onto the control surface.
PORTS AVAILABLE FOR CSCP CONNECTIONS
• Standard 8U processing core
• 4U Artemis Light core
Primary Calrec controller ports
Secondary Calrec controller ports
72 ARTEMIS Digital Broadcast Production Console
External Control
SYSTEM STATUS OVER SNMP
SNMP AGENT - SYSTEM STATUS TAB
SNMP AGENT - SNMP CONFIGURATION TAB
SNMP AGENT - HTTP CONFIGURATION TAB
All Calrec consoles feature System
Status - an advanced warning and
correction system. System Status
messages can be managed centrally
using an SNMP (Simple Network
Management Protocol) server.
All Calrec console and Master Router PCs
provide an SNMP agent to forward error
and warning messages to a central SNMP
server, allowing equipment faults to be
monitored and managed from a central
location. A connection can also be made
to a second SNMP server if required for
redundancy.
Connecting to the SNMP server
A USB to ethernet adapter is provided
with each console PC for connecting to
your central SNMP server. If multiple
SNMP servers are used this connection
should be made to a network switch to
allow multiple onwards connections.
Router cores are provided with a rack
mount PC which has a spare ethernet
port to be used for connecting to your
central SNMP server.
In both cases the ethernet ports used
must be configured to be in range of your
central SNMP server before configuration
can continue.
Configuring the SNMP Agent
Each console/router core PC's SNMP
agent must be configured individually.
This can be done from the local PC by
opening Google Chrome and entering
'localhost' in the address bar as shown
here. SNMP agents can also be
configured remotely by entering the IP
address of the PC where the SNMP agent
is running, including the port number
(default: 80).
The SNMP Agent interface has 3 tabs.
The System Status tab shows a list of
the current System Status errors and
warnings for the console or router that you
are accessing.
Enter the IP address of the facility's
main SNMP server within the SNMP
configuration tab under 'address 1'; this is
where the SNMP agent and SNMP server
are connected together. If a second
SNMP server is used enter its IP address
under 'address 2'. After making any
changes, click SUBMIT & RESTART.
The HTTP configuration tab allows you
to set the port number for access to the
SNMP agent configuration interface,
the default is port 80. If changes are
made here, the port will need to be
specified when accessing the SNMP
agent interface, for example, if the port
is changed to 10, type 'Localhost:10'
in Chrome's address bar to access the
SNMP agent interface. After making any
changes, click SUBMIT & RESTART.
Scope of System Status over SNMP
Only System Status error and warning
messages are sent via SNMP, information
messages are not sent. When errors are
corrected, the relevant System Status
messages are cleared from the PC
Main application and are simultaneously
cleared from the SNMP server.
CALREC Putting Sound in the Picture
73
WIRELESS ROUTER CONFIGURATION – ASSIST
Calrec’s Assist apps are connected
to the console via a wireless router.
The setup options provided by
different router manufacturers can
differ substantially so this setup
guide should be used along with
the manufacturer's instructions for
your particular router configuration
application. Also, some basic
networking knowledge is assumed.
Calrec serial control protocol (CSCP)
allows communication with Calrec
consoles using the TCP/IP protocol at a
pre-determined TCP port number.
Assist apps run on iPad devices which
connect to the Calrec system through a
wireless router, through which console
functions can be controlled using CSCP.
Console Configuration
From software version 1.14.7 onwards,
Calrec consoles are pre-configured with a
basic ‘Assist’ CSCP configuration which is
disabled by default.
This basic configuration assumes a
simple, point to point connection with
a wireless router on a 192.168.1/24
subnet. This basic setup is unlikely to be
suitable for connection to a more complex
corporate network.
To enable the basic Assist connection,
select System Settings from the menu
along the bottom of the main application,
then select Ext Control from the
left hand menu and click to ENABLE
‘assist(CSCP v21)’.
The console will now be providing the
CSCP connections shown in this table.
IP Address
Subnet Mask
Port Number
Primary Control
Processor
192.168.1.1
255.255.255.0
49300
Secondary Control
Processor
192.168.1.2
255.255.255.0
49300
ASSIST CSCP ENABLE
74 ARTEMIS Digital Broadcast Production Console
External Control
Wireless Router Configuration
When the basic ‘Assist’ configuration has
been enabled the console provides CSCP
connections on the 192.168.1/24 subnet
so the wireless router LAN connection
must be configured to be part of this
subnet. We advise that the wireless router
is configured with a LAN IP address of
192.168.1.3 and an IP subnet mask of
255.255.255.0
DHCP Configuration
To connect hand held wireless devices,
such as the iPad, the wireless router
should be configured to provide a DHCP
(Dynamic Host Configuration Protocol)
server to distribute IP addresses to these
hand-held devices.
The wireless router should be configured
as a DHCP server: The IP Start
address or IP Pool address should be
configured to be 192.168.1.100 and the
IP or DHCP pool size should be set to
4.
This allows up to four wireless devices
to be connected to the console
simultaneously. They will be allocated IP
addresses in the range: 192.168.1.100 to
192.168.1.103.
DNS (Domain Name System) parameters
are not required for this setup.
Other Configuration Parameters
Wireless routers provide many different
services and it is not possible to cover
all setup permutations in this document.
Some common considerations are:
• Firewalls should be disabled if possible.
If not then the firewall should be
configured to enable TCP/IP traffic in
both directions on port 49300.
• NAT (Network Address Translation)
should be avoided.
• Packet filtering and MAC address
filtering should be avoided.
WIRELESS ROUTER TO CONTROL PROCESSOR CONNECTION
IPAD, CONSOLE AND WIRELESS ROUTER CONNECTIONS
CALREC Putting Sound in the Picture
75
Security Considerations
The wireless LAN (and therefore the
console) is open to any devices that
can discover the wireless network and
have access to the encryption keys. It is
strongly recommended that the wireless
LAN is configured to use some method
of encryption. WEP is considered to be
insecure so as a minimum you should
select WPA(2)-PSK. This requires both
communicating parties to agree on the
same keyword or passphrase before
access is allowed.
Assist Application Configuration
Assist applications should be configured
with a CSCP IP address of 192.168.1.1 to
connect to the primary control processor
or 192.168.1.2 to connect to the
secondary control processor. The CSCP
port number should be set to 49300.
To access these settings, launch one of
the Assist apps on an iPad and tap NEW
in the top right hand corner to add a new
connection. Enter your settings, as shown
here, then press DONE. (The number
of faders should reflect the number of
faders on your desk and the 'Connection
Label' can be customised to reflect your
particular connection.)
ASSIST APP CONFIGURATION
76 ARTEMIS Digital Broadcast Production Console
External Control
RS232/422 CONVERSION
Remote control connections to Calrec
Apollo, Artemis and Hydra2 systems
are made via TCP/IP. 3rd party
controllers that use point to point
true RS232/422 serial will require
convertors to connect to the Calrec
system.
Various options are available for serial to
TCP/IP conversion, Calrec recommend
the use of, and can supply dual PSU
Perle IOLAN SCS8's. Calrec chose this
unit specifically for its dual power supply
option, its 1U rack mount enclosure, and
its flexible data routing options.
Fitted with 8 x RS232 serial ports and 2 x
Ethernet ports. Data can be routed from a
single serial port controller to both primary
and secondary Calrec connections.
Controllers with a backup port, or systems
with backup controllers can route the
normally active port to the Calrec primary
card, and the backup to the secondary.
For 3rd party controllers that operate on
RS422, Calrec can also supply in-line
RS232-422 cable convertors (Calrec
stock code 312-269) to use in conjunction
with the Perle SCS8.
The Perle unit needs to be configured to
connect to the Calrec Hydra2 network's
Master Router card/s (SW-P-08 /
EMBER) or each console's Controller
card/s (CSCP) by their IP addresses. In
cases where the default Calrec card IP
addresses are not suitable, as can be
the case if data is being passed over
a shared Ethernet infrastructure, the
Calrec hardware can be configured to be
accessed by alternative IP addresses.
PERLE IOLAN SCS8 - FRONT
PERLE IOLAN SCS8 - REAR
8 x RJ45 RS232 serial ports
2 x RJ45 Ethernet ports
RJ45 RS232 Console port
CONNECTIVITY EXAMPLES
Perle RJ45 pins
Signal (Perle I/O)
Standard D9 pins
1
DCD (in)
1
2
RTS (out)
7
3
DSR (in)
6
4
TxD (out)
3
5
RxD (in)
2
6
Gnd
5
7
CTS (in)
8
8
DTR (out)
4
PERLE RS232 SERIAL RJ45 PIN-OUT
CALREC Putting Sound in the Picture
77
Perle units supplied by Calrec can
be pre-configured if the connectivity
requirements are communicated prior
to delivery. Please discuss 3rd party
control integration with your Calrec
sales representative or assigned
project leader.
Configuration requires that the IP
addresses of the Perle unit itself are
known. If the addresses are not known, or
have yet to be configured, the first stage
requires a serial Telnet connection to the
front panel console port, labelled Admin.
Telnet IP configuration
The front panel Admin console port, like
the rear panel serial ports is RS232 on an
RJ45 connector.
Perle supply the units with a number of
various cable adaptors. Use the female
D9 to RJ45 socket adaptor, along with an
Ethernet cable, to connect a PC serial port
to the Perle front panel Admin console
port (the RJ45 plug to RJ45 socket cable
adaptor, labelled 'Console Port' is not
required).
Launch a Telnet application on the
PC. The following instructions are
based around using HyperTerminal,
which is normally pre-installed on
Windows PC's. HyperTerminal
can be found under Windows
Start>All Programs>Accessories>
Communications.
On starting a new HyperTerminal session,
you are required to enter a name of
your choice and select an icon. On the
following page, select COM1 (or the PC
port being used if different) from the
Connect Using drop-down menu.
Enter the port settings on the following
page as follows; bits per second: 9600,
data bits: 8, parity: none, stop bits: 1,
flow control: none.
PERLE IOLAN CONFIGURATION
Once the connection is configured, the
main HyperTerminal window should be
in view. Ensure the connection is active
by clicking the Call icon (telephone
with handset down) at the top of the
HyperTerminal window. If the icon is
greyed out, it is already connected.
Once HyperTerminal is connected, power
up the Perle unit. On boot up, messaging
from the Perle unit should be displayed in
the HyperTerminal window. Once booted,
you should be greeted with a login prompt.
To login, enter admin,for the password,
enter superuser . A successful login
is greeted with the unit's model number
(SCS8#).
Enter the following to set the IP address
for the Perle Ethernet port 1: set
server internet eth1 xxx.xxx.
xxx.xxx (substituting xxx.xxx.xxx.xxx
with the desired IP address). Enter the
following to set port 2: set server
internet eth2 xxx.xxx.xxx.xxx
Enter save then y to confirm and
retain the changes.
Note, the IP addresses chosen for
the Perle unit need to be in a range
compatible with those of the Calrec cards
being connected to (or their alternate,
aliased IP addresses).
Cycle the power to the Perle unit to
reboot and view the startup messaging to
confirm the IP addresses have been set
correctly. Note, in the boot up messaging,
port 1 is displayed as 'eth0' and port 2
'eth1' - this is contrary to the commands
required to set the IP's.
Call (connect) icon
Disconnect icon
Main configuration - Web Manager
Once the IP addresses of the Perle unit
are known, the main configuration can be
carried out.
Connect an Ethernet cable from a PC
Ethernet port to one of the two Ethernet
ports on the rear of the Perle unit.
Configure the network connection of the
PC to be in a compatible IP address range
with the Perle unit. Launch a web browser
on the PC and enter the IP address of the
Perle's port 1 into the browsers address
field to bring up the Perle Web Manager
application.
Enter admin for the username and
superuser for the password to log in.
Select the Configuration>Network>IP
Address / IP Settings page, either from
the tree on the left, or by the selection
buttons in the main screen (screenshot
shown overleaf). The addresses of
both Perle ports are shown on the IPv4
settings page. If required, the subnet
mask for each port can be changed, and
also the IP addresses themselves can be
changed. Click Apply if any changes are
made.
Note, that Web Manager page changes
can be slow and do not always fully display
the content. If content is missing, change
away from the page and back, rather
than just refreshing. Check the browser's
progress bar to see when pages have
finished loading.
Select the Network>Advanced page
(Not the Network>IP Address>advanced
page). Click Add to add a new host to
the host table. Enter a name, eg 'Calrec-
Primary' and the IP address (or alternate,
aliased IP address) of the primary Calrec
card that the Perle will connect to.
78 ARTEMIS Digital Broadcast Production Console
External Control
Repeat to add the secondary Calrec card
as another host. Click Apply to save the
changes.
Select the Serial>Serial Port page.
Select port 1 and click Edit to view the
details for the serial port. At the top of the
page, below the port label, click Change
to select the TCP sockets profile, click
Apply and then Return to Serial 1.
Select the Hardware tab and enter serial
port settings that match that of the 3rd
party controller. Common settings are;
Serial Interface: EIA-232, Speed:
115200, Data Bits: 8, Parity: Odd,
Stop Bits: 1, Flow Control: None.
Click Apply.
If a backup controller serial connection
is being used, repeat the above for serial
port 2.
Select the General tab for serial port
1. Check Connect To, and select the
primary Calrec card from the Host drop-
down list (as was previously defined from
the Network>Advanced page). Enter a
TCP Port number to match the protocol
being setup (61000 for SW-P-08, 62000
for EMBER. The CSCP port is selectable,
as defined by Calrec StudioSetup, the
default value being 49200).
Select Initiate Connection
Automatically, and check Send Name
On Connect.
If Ethernet cable and port redundancy
is required from a single serial port
controller, check Connect To Multiple
Hosts, then click Define Additional
Hosts. Click Add and select the Calrec
secondary card from the Host list, and
enter the TCP port number required
for the protocol being used. Click OK.
Ensure that Define primary and backup
Once completed, click Reboot IOLAN
or cycle the power to the unit for the
configuration changes to take.
PERLE WEB MANAGER - NETWORK>IP ADDRESS PAGE
PERLE WEB MANAGER - NETWORK>ADVANCED PAGE
hosts to connect to is NOT selected,
and then Apply.
If there is a backup 3rd party controller
serial connection, do not select serial port
1 to connect to multiple hosts. Instead,
Configure serial port 2 to connect to the
Calrec secondary card.
192.168.1.10
192.168.2.10
192.168.1.10
255.255.0.0
255.255.0.0
192.168.1.0
192.168.2.0
192.168.1.10
CALREC Putting Sound in the Picture
79
PERLE WEB MANAGER - SERIAL>SERIAL PORT PAGE
PERLE WEB MANAGER - SERIAL>SERIAL PORT, PORT 1, HARDWARE PAGE
PERLE WEB MANAGER - SERIAL>SERIAL PORT, PORT 1, GENERAL PAGE
ADDITIONAL HOSTS
192.168.1.10
192.168.1.10
82 ARTEMIS Digital Broadcast Production Console
Setup & Configuration
This section covers areas often
required by installation engineers
to carry out the initial setup and
configuration that is required to
test the installation and provide a
starting template for operators to
work with.
Please refer to the console operator
manual and the H20 user guide for more
comprehensive information on user
functionality.
The console PC should boot from control
surface power on. If the PC has been
shut down, it can be restarted by pressing
the reset button behind the keyboard.
The default Windows user is 'calrec' and
requires no password. Once logged in,
the Calrec main application should start
up. If the main application is closed, it
can be restarted from the Windows Start
menu. Once open, the main pages can be
selected by clicking on their icons across
the bottom of the GUI. Most pages have
sub-pages which can be accessed by
the menu buttons at the left hand side of
each main page. Some settings within
the main application are protected and to
make changes the user must be logged
in as a Technician. Technician access is
gained from the Tech page by clicking
on Technician. If no users have been
setup, the system allows the creation of a
supervisor login. Supervisors are able to
create and delete other technician user
logins.
H20 - Hydra2 Organiser is an
administrator level GUI that provides
control over the whole network. H20
can be accessed via a web browser
running on a PC connected to the Master
Router. This can be a console PC (if the
master router core has a console directly
attached to it), or a PC connected directly
to a spare RJ45 on the front of the active
Control Processor card in the Master
OVERVIEW AND GUI ACCESS
Router core. H20 is fully supported by
Google Chrome which is pre-installed on
Calrec supplied PC's with a bookmark
to the H20 address (IP address of the
Control Processor)
Once open, H20 screens are accessed
using the menu across the top of the GUI
window.
Some features, such as accessing the
Calrec program updater and admin level
Windows settings require the user to log
into Windows as an administrator. The
user CalrecAdmin is setup up with the
password calrec.
CALREC Putting Sound in the Picture
83
CREATING A CLEAN STARTING POINT
To ensure you are starting from
a clean setup, before beginning
configuration it is a good idea to
create a new show.
Shows contain default settings for the
console, including monitor patching,
GPI patching and port labelling. Shows
can contain multiple user memories
which save normal I/O patching, fader
assignment and path parameter settings.
To create a new show, go to the Mem
page and select New Show. Choose the
Calrec Default as the starting template,
enter the details as prompted and click
Next to load the new, clean show onto the
console.
The same Mem page allows changes
to the show to be saved, as well as
other shows to be loaded, and for user
memories within shows to be loaded and
saved.
MAIN APPLICATION - MEM SCREEN
84 ARTEMIS Digital Broadcast Production Console
Setup & Configuration
The control surface display brightness
can be adjusted and the surface
enters a screen saver / 'Dark Mode'
after a period of inactivity.
During dark mode, the displays are
switched off, but all control and audio
processing continues. The displays
will instantly switch on if any control is
changed. Touching a fader knob (without
even moving the fader) will activate its
touch sensor and bring the surface out
of dark mode straight away, without
changing control parameters. A 'Dark'
button/LED on the monitor panel flashes
to indicate when the console is in this
mode.
Pressing the Dark button on the monitor
panel will also put the console into this
mode, without waiting for the timeout.
The above settings can be
accessed from the main application,
>System Settings>Surface Illum
page. Note that the maximum dark mode
timeout is 1 hour and cannot be disabled.
SCREENSAVER TIMEOUT - 'DARK-MODE'
CALREC Putting Sound in the Picture
85
SYNC SETUP
Artemis processing cores are capable
of running on their own internally
generated synchronisation clock,
however where more than one core
is networked together, it is essential
that they are all fed and locked to the
same derived sync source to ensure
clean audio and seamless system
data transmission.
Even with a single Apollo / Artemis
console, general rules of good practise
dictate that the audio console should be
locked to the same derived sync source
as the surrounding digital equipment for
clean transfer of audio between devices.
Physically, sync inputs are on BNC
connectors located across the top of
the processing core, as described in the
Connection Information section.
By default, the system will choose to
lock to its internal clock. On initial setup,
each console's external sync input priority
should be setup.
Sync input priority can be set locally on
each console's main application, or it can
be set via H20. Neither GUI has priority
over sync choice. Changes made on
either user interface are reflected by the
other.
Where standalone router cores (without
a control surface attached) are used to
expand the network, it is essential that
the same sync source(s) are connected
and selected as the other cores on the
network. Sync settings for standalone
cores can only be accessed via H20.
Main Application Sync
Using the local user interface on each
console, sync is set from the
>System Settings>Sync page.
To make any changes to this page, the
user must be logged in as a technician
(see overview and GUI access).
The Sync page displays the available
sync sources on the left hand side, and
the priority list on the right hand side.
The priority list displays six sources, the
last of which is fixed as internal. The first
5 sources can be selected by highlighting
the chosen source on the left, highlighting
the chosen priority list entry on the right
and clicking patch. When selecting a
video source, the user should also select
the specific video format being used from
the central list.
On startup, the system attempts to lock
to the first entry in the priority list. If there
is a problem with this source, the system
moves down the list until a source is
found that can be locked to. The 'current'
column shows which of the sources the
system is locked to. System Status error
messages are generated for any sources
that fail when the system attempts to
lock to them. Once running and locked,
the system will not automatically go back
to a higher priority source if it becomes
available. Clicking Reset to first
instructs the system to go back through
the list attempting to lock to the highest
priority source it can find. This can be
an important requirement for systems
that get powered down as a whole, such
as outside broadcast units, as sync
generators can often take longer than the
console to boot up.
H20 Sync
The Sync Sources page displays the
sync settings for all consoles and router
cores that have been added to H20's
client database. If the console being
configured does not exist in the client
list on the left of the screen it should be
added to the client database from the
Manage Clients page (See H20 User
Guide for more information). On the sync
page, select any console or core from the
clients list on the left to view their sync
settings on the right. The right hand side
of the screen acts the same as the main
application, displaying the currently locked
source, allowing the sources in the sync
priority list to be changed and providing a
'reset to first' function. Changes made via
H20 are reflected in the main application
on the console they affect. Likewise, any
subsequent changes made locally will be
reflected by H20.
86 ARTEMIS Digital Broadcast Production Console
Setup & Configuration
I/O CONFIGURATION
The >Hydra Settings>Edit Network
screen in the main application
displays the available I/O boxes on
the network.
The left hand side of the screen shows all
the I/O boxes that are online - powered,
connected and functioning.
I/O boxes that are required for use by the
console should be added to the network
config of that console by highlighting the
required box on the left and clicking the
Add>> button in the central area.
The right hand side of the screen shows
all the I/O boxes that have been added to
that console's configuration. If a box that
has been added is offline, it is displayed in
the list in red font and denoted as 'Offline'.
IO boxes no longer required, or added by
mistake can be removed by highlighting
them in the right hand required list and
clicking the < EDIT NETWORK SCREEN
CALREC Putting Sound in the Picture
87
Assignable faders
Each fader has an A and B sub-layer,
which can be switched between by
pressing the assign buttons above and
below the fader's label display. The
two sub-layers, A & B are not related
by default and can control two distinct,
unrelated audio paths. The upper half of
the fader label display is green and refers
to the A layer, the lower half is yellow and
refers to the B layer. An open fader will
remain open and passing audio after the
layer is changed.
Pressing the assign button above (A
layer) or below (B layer) the label display
makes it the currently assigned path
and highlights it blue. Only one path
(unless user splits are in place) can be
the currently assigned path at any given
time. Path specific changes are applied to
the currently assigned path. For example,
adjusting settings on an assignable panel
in PROCESSING or SEND-ROUTE
mode will affect the currently assigned
(highlighted blue) path.
In addition to A & B sub-layers, there are
in fact a total of 12 fader layers, each with
an A & B sub-layer. All layers and A/B
sub-layers are active irrespective of which
is currently visible. Fader layer is selected
from the assign row (control cell row
above the fader label row) of any panel.
Assigning paths
A or B layer faders with a blank label
field have no DSP path assigned.
Path assignment is achieved from the
Tools>Fader Assignment menu (see
the highlighted drawing to the right).
Select New Channels to assign input
channels. Three channel widths are
currently supported - Mono, Stereo and
5.1. Pressing one of these buttons will
assign that channel type to the currently
assigned fader (as long as no path is
already assigned on that fader).
PEAK
STRIP
FDR
CUT/ON
AUTOM
EXT
CUT
MR
SL
MR
SL
PEAK
STRIP
FDR
CUT/ON
AUTOM
EXT
CUT
MR
SL
MR
SL
PEAK
STRIP
FDR
CUT/ON
AUTOM
EXT
CUT
MR
SL
MR
SL
PEAK
STRIP
FDR
CUT/ON
AUTOM
EXT
CUT
MR
SL
MR
SL
PEAK
STRIP
FDR
CUT/ON
AUTOM
EXT
CUT
MR
SL
MR
SL
PEAK
STRIP
FDR
CUT/ON
AUTOM
EXT
CUT
MR
SL
MR
SL
PEAK
STRIP
FDR
CUT/ON
AUTOM
EXT
CUT
MR
SL
MR
SL
PEAK
STRIP
FDR
CUT/ON
AUTOM
EXT
CUT
MR
SL
MR
SL
Currently assigned path
(highlighted blue)
1. Tools menu
2. Fader
Assignment
3. New channels
menu
ASSIGNING PATHS TO FADERS
To assign the same channel type to
multiple faders, press and hold the
channel type button whilst selecting the
faders you wish to be assigned.
To clear a path from a fader, select the
Layer Tools menu (Button above Tools).
Press Clear Path from the row above
then Exec to clear the currently assigned
path. To clear multiple paths, press and
hold Clear Path whilst selecting the faders
to clear before confirming by pressing
Exec.
88 ARTEMIS Digital Broadcast Production Console
Setup & Configuration
USING TONE
Use of the console's internal oscillator
helps to verify connectivity and
configuration during installation.
Tone can be selected to path inputs from
the PROCESSING panel mode.
The tone to input select button is located
on the left side of the TFT screen.
Selecting this switches tone onto the
currently assigned path's input.
Selecting the Tools>Oscillator menu on
any panel brings up oscillator controls on
the row above to allow adjustment of tone
level, frequency and idents.
The Tone Clear button in this menu will
cancel all tone to path selections across
the console.
Select the Send / Route panel mode to
route the currently assigned fader to bus
outputs from the TFT touch screen above.
Note, tone can only be selected to faders
that have a DSP path assigned (see
previous page).
STRIP
FDR
CUT/ON
AUTOM
EXT
CUT
MR
SL
MR
SL
STRIP
FDR
CUT/ON
AUTOM
EXT
CUT
MR
SL
MR
SL
STRIP
FDR
CUT/ON
AUTOM
EXT
CUT
MR
SL
MR
SL
STRIP
FDR
CUT/ON
AUTOM
EXT
CUT
MR
SL
MR
SL
STRIP
FDR
CUT/ON
AUTOM
EXT
CUT
MR
SL
MR
SL
STRIP
FDR
CUT/ON
AUTOM
EXT
CUT
MR
SL
MR
SL
STRIP
FDR
CUT/ON
AUTOM
EXT
CUT
MR
SL
MR
SL
STRIP
FDR
CUT/ON
AUTOM
EXT
CUT
MR
SL
MR
SL
**Select PROCESSING mode**
Fader layer select
Currently assigned path
(highlighted blue)
Select tone to currently
assigned path input
CALREC Putting Sound in the Picture
89
MONITORING OUTPUT SETUP
Artemis consoles do not have
dedicated outputs for feeding
monitors. Monitor outputs can be
patched to any Hydra2 audio output
port on the network.
Monitor output patching is separated from
other I/O patching as it generally remains
fixed irrespective of operators and the
shows being worked on. Patches made
from the fixed I/O pages are saved as part
of the show.
Monitor outputs can be found on the
>System Settings>Fixed I/O screen.
Click on the Sources button at the
top left of the screen to bring up the
source lists available and select Monitor
Outputs from the My Desk Outputs
group to display the monitor output
sources in the left hand list. The normal
default monitor output is at the top of
the list, labelled Mon1 Main LS. Other
monitor sources that are likely to be of
interest for initial setup are PFL1/RTB LS
and Mon1 Small LS. PFL/RTB LS outputs
carry the pre-fader listen bus mixed with
any reverse talkback inputs that have
been enabled. Mon1 Small LS is often a
preferable way to monitor PFL which is
routed to the small LS output by default.
In changeover mode, the main monitor
output is muted and instead sent to the
small LS.
Patching monitor outputs is similar
to normal I/O patching - click on the
destinations button above the right
hand list and select the list containing the
I/O ports that the monitor speakers are
physically connected to from the Output
Ports group. Select the specific port
a speaker is connected to within that
list by highlighting it on the blue column
as shown in the adjacent screenshot.
Select the required monitor output source
on the left, again by highlighting in the
blue column (as shown in the screenshot)
and click patch. Once patched, the
destination list should display the patched
audio source.
As well as the standard Main Mon LS1
and PFL outputs there are also Mon2
and APFL2 outputs that are independent
for when multiple operators are using the
same system simultaneously. A number
of Misc Monitor outputs are also available
and can be used to feed anywhere that
needs an independent selector with a
level control. One potential use for these
can be to feed the analogue headphone
inputs to the control surface.
Speaker configuration
The detailed setup of monitor
systems should always follows the
recommendations of the loudspeaker
manufacturer. When surround monitor
systems and others with a separate LFE
or sub-bass channel are in use, it is often
good practise to use a bass management
system. Such controllers frequently
provide not only for their primary function
of optimising the speaker performance,
but also individual level trim functions.
The Calrec system itself does not provide
level adjustments or delay for adjusting
the individual channels within the monitor
output.
MAIN APPLICATION, SYSTEM SETTINGS > FIXED I/O
90 ARTEMIS Digital Broadcast Production Console
Setup & Configuration
METERING SETUP
Calrec TFT meters
The high resolution upstand TFT metering
can display fader input audio, bus output
audio as well as external meters that
display audio fed to chosen Hydra2 input
ports. As well as audio, upstand meters
can display dynamics' gain reduction.
Audio data for the TFT meters (and fader
bed bargraphs) is generated by DSP and
sent to the control surface via the Control
Processor to console Surface Switch link.
TFT metering is customisable
from the Main Application >Show
Settings>Meter Layout screen.
This screen shows one TFT meter panel
at a time, different panels can be selected
from the column on the left hand side
of the screen. Selecting Grid allows
the layout to be changed. Highlighting
a meter cell and selecting Edit Meter
brings up a choice of meters that can be
displayed. Set Scale provides a choice
of VU or PPM meter ballistics and scales.
Once happy with the meter setup, it is
transferred to the console by clicking
Apply new layout to surface at the top
right of the screen. The meter layout can
also be saved as a Meter Layout Preset
for later use, note that the meter layout
is now saved with the show rather than a
seperate file. The Meter Presets can be
reloaded back into the layout screen and
applied to the surface when required.
Moving coil and third party meters
Traditional PPM / VU moving coil meters
and 3rd party meters such as RTW / DK
surround scopes cannot access DSP
meter data and need to be fed audio
via the control surface rear interface.
If required, this audio can be fed from
Hydra2 output ports. This may be a
fixed feed, such as Main1 Line, patched
from the regular I/O page, or it can be
a changeable source, patched from
>System Settings>Fixed I/O.
Under the sources>desk outputs group,
as well as monitor outputs, there are
also External Meter Outputs. Various
sources are available in this list, including
Mon LS Pre which outputs / follows
the same audio as being monitored by
the Main LS but pre the LS listening level
control.
Also available are Meter selectors 1-4.
These are four selectors without level
controls accessible on the monitor panel
which have access to all the sources that
the monitor LS does but independent of
the LS selection.
Meter selector outputs can also be
displayed on Calrec TFT meters without
patching them to Hydra2 outputs.
MAIN APPLICATION - SHOW SETTINGS > METER LAYOUT SCREEN
CALREC Putting Sound in the Picture
91
The dedicated monitor panel on the
control surface provides access
to the commonly used monitoring
controls. Access to the full set of
monitor controls can be gained from
any fader panel / up-stand TFT screen
combination by selecting Monitor
mode.
The following page shows the assignable
area of a fader panel / up-stand TFT
combination in Monitor mode with
important areas highlighted.
Assignable area mode selection is chosen
from the row of controls above the fader
label displays. Use the down arrow
buttons above the displays to select the
desired mode. If the expected mode is
not displaying, the panel is more than
likely in Tools, or Layer Tools mode - Press
Exit, or the Tools / Layer Tools button
from the bottom right of the assignable
area to return to the chosen mode.
Ensure the panel is controlling the
required output - Monitor 1 or Monitor 2
(control cell highlighted on the following
page).
Four pre-selectors determine the audio
being monitored. Switch between the pre-
selector sources by pressing the 'Hear'
buttons. To select a different source on a
pre-selector, press its' 'Sel' button to make
it the focus of the selector panel on the
TFT screen above. Selectable sources
are separated into categories, chosen
from the 'Selector Type' menu at the
bottom of the TFT screen.
A control cell on the dedicated monitor
panel, to the left of the large yellow level
control, shows the sources on each pre-
selector and allows for switching between
them without accessing the full monitor
panel.
MONITOR / METER SOURCE SELECTION
In the full monitor panel mode, to the left
of the 4 monitor pre-selectors are the
4 meter selectors. Press 'Sel' on the
appropriate meter selector to change the
source in the same way as for the monitor
selectors.
To the left of the Main monitor LS level
control, on both the dedicated and full
monitor panel is a Small LS control cell.
By default, the Small LS outputs PFL
audio. If Small LS C/O (Change-over) is
selected, it will kill the main monitor output
and instead send the selected audio to the
small LS outputs, irrespective of whether
the small LS is patched to physical output
ports / speakers.
Another control cell sets the listening level
of PFL and AFL audio.
Individual LS channel cuts provide a
convenient way to check patching and
connectivity.
92 ARTEMIS Digital Broadcast Production Console
Setup & Configuration
Source Selection
Source Type
Selection
LS pre-selectors 1-4
Press 'Hear' to listen,
press 'Sel to select a
different source
LS output level
control and cut
Individual LS
channel cuts
Select to control
Mon1 or Mon2
output
**Select Monitor mode**
ASSIGNABLE AREA (LOWER SECTION OF UP-STAND TFT + UPPER SECTION OF FADER PANEL), IN MONITOR MODE
CALREC Putting Sound in the Picture
93
INPUT & OUTPUT PORT PATCHING
Regular Input and output port
patching is similar to that of patching
monitor outputs but done from the
I/O screen of the main application
and the patches are saved as part of
the user memory.
Note that the same input and output ports
are available on the I/O screens as the
Fixed I/O screens. Patches made from
the Fixed I/O screen are visible on the
I/O screens and denoted by the System
Settings page icon. Likewise when
viewing the Fixed I/O screen, patches
made to ports from the I/O screen are
visible and denoted by the jack icon used
for the I/O page.
The I/O screen shows sources on the left,
and destinations on the right. To patch
input ports to channel paths on faders,
press Select Destination, then select
Channel I/P's from the My Desk Inputs
group. The destinations field now displays
the faders on the console.
From the Select Source button, the
Input Ports contains the input port lists.
If the port lists have not yet been edited,
there will be a default list containing all
ports, and a list for each I/O box labelled
with the box ID.
Highlight the chosen input port(s) on the
left by clicking on the blue cell. Highlight
the chosen fader by selecting the blue
cell(s) and click patch to put the input port
on the fader. Faders with no DSP path
assigned cannot be patched to.
To patch console output audio to Hydra2
output ports, press Select Source and
choose My Desk Outputs. Select the
required output port list from the Output
Ports group of the Select Destination
menu. Again, patching is achieved by
highlighting the blue source cell, the blue
destination cell and clicking patch.
Select Source
Patch
Change source list / source type
Change destination list / destination type
Change fader layer
Select Destination
94 ARTEMIS Digital Broadcast Production Console
Setup & Configuration
TALKBACK AND EXTERNAL TONE
All Calrec consoles have a
comprehensive talkback system to
allow operators to talk over output
buses and channel direct outputs /
mix-minus outputs.
An XLR on the up-stand reset panel
provides a convenient location to mount
the supplied gooseneck microphone.
This is wired internally to an XLR on the
console rear interface. To use this as part
of the console's talkback system it should
be connected to a Hydra2 mic input. If
the console talkback system is not going
to be used, the mic can be wired into an
external comms system if it is convenient,
i.e. for use as a hot-mic or in conjunction
with a foot switch, or an assignable
monitor panel button patched to GPO.
The Hydra2 input port with the
mic connected should be patched
to the talkback input from the
>System Settings>Fixed I/O>Select
Destination>My Desk Inputs>Tone &
TB screen - The top entry in this list is the
Talkback mic input.
The same screen allows for patching of
reverse talkback and external tone inputs.
Audio from Hydra2 inputs patched as
reverse talkback is sent to the PFL/RTB
LS outputs. Ports patched as external
tone inputs replace the consoles internal
tone generator when the oscillator
controls from panel tools mode are set to
external.
Ports are patched in the same way as
normal I/O - View the appropriate port
list using the select source button, then
select the required source on the left
by highlighting the blue cell. Select
the destination on the right, again by
selecting the blue cell, and then click
patch from the central area. Additional
fields on the right allow the switching of
SRC, phantom power and analogue input
gain, dependant on the type of input port
patched.
MAIN APPLICATION - SYSTEM SETTINGS > FIXED I/O
CALREC Putting Sound in the Picture
95
GPIO assignment is achieved from
the >Hydra Settings>GPI & GPO
pages.
Select the GPO page to patch functions
to GP output relays. The left-hand side of
the screen shows the functions available
to patch. Click on the functions button at
the top of the list to view different function
types by group. The relay outputs are
shown on the right and the list can be
filtered by I/O box using the Filter button.
To make an assignment, highlight the
function and the relay, and then click
patch. The Test button allows each relay
to be triggered to check wiring.
GP inputs are assigned from the GPI
screen in a similar way. The inputs are
shown on the left and can be filtered by
I/O box. The functions to be triggered are
on the right and are split in to groups by
function type, selectable from the Filter
Functions button.
GPIO patching is saved as part of the
show, rather than in each user memory.
ASSIGNING GPIO
MAIN APPLICATION - HYDRA SETTINGS > GPO PATCHING SCREEN
96 ARTEMIS Digital Broadcast Production Console
Setup & Configuration
USER CONTROL LOGGING SETUP
The requirement for comprehensive control change logging, has been provided to allow after-the-fact analysis of
production problems.
Basically the system captures control data and attaches a timestamp to establish when various controls changes were applied by the
operator on Apollo, Artemis and Summa Consoles and puts the results into a logging file. The logging file is held on the MCS cards
and requires the following entry to be added to the Studio Setup File as shown below:-
Once the User Logs are created on the MCS cards they can be opened using a Web-Browser which initially displays a Directory of User Logs.
When the required log a selected log is accessed a timestamped Table of Control data appears for further analysis.
As well as memory, preset, fader open/close, path copy/paste,time, CSCP and Path events, logging is implemented for as many of the
desk controls listed below as possible.. These are shown in a list of Path Controls on the following pages.
Those marked as (U) are unavailable and indicate that either the control was not available or that the control does not exist..
Filtered events (F) will only be filtered when showing absolute values ('set to') but not when showing changes i.e. ('modified by').
#######################################################################################
#####################
#
User Logging
#
#######################################################################################
#####################
# set to ‘true’ if wanting to enable user logging i.e. 'UserLoggingEnabled = true' (if commented out or
# missing it will default to false)
UserLoggingEnabled = true
# The time between file updates in seconds e.g 'UserLoggingFileUpdatePeriod = 5' Minimum value is 1 second
# (if commented out, missing or too low it will default to 1 sec). Note that this also affects the refresh
# period of the shaft and fader level logging so, if you want more resolution on fader movement, then make
# this number smaller, or bigger if you want less fader/shaft messages
UserLoggingFileUpdatePeriod = 1
# Clock time when the current logging file is closed and a new one is started. Format is 24 hour format
# hour:minutes e.g. 'UserLoggingFileRolloverTime = 08:04' (if commented out or missing it will default to
# 00:00). Range is 00:00 to 23:59
UserLoggingFileRolloverTime = 00:00
# The maximum disk space on the Master Controller card to allocate to the logging files in MB. When this
# space is exceeded, older files shall be deleted e.g 'UserLoggingFileFolderMaxStorage = 5' (if commented
# out or missing it will default to 10 MB). It is up to the user to put in sensible values here but, as a
# guide, 100MB would be much much more than you ever needed.
UserLoggingFileFolderMaxStorage = 10
# You can filter out event types that are logged by adding them to the following list where:
# 0 = PATH_CONTROL_EVENT
# 1 = DESK_CONTROL_EVENT (fader section and panel events)
# 2 = MEMORY_EVENT
# 3 = PRESET_EVENT
# 4 = TIME_EVENT
# 5 = FADER_OPENCLOSE_EVENT
# 6 = PATH_COPYPASTE_EVENT
# 7 = CSCP_EVENT
# So, for example, if you only wanted Path and fader open/close events but wanted to know when a logged fader
# event might be caused by CSCP then you would use: 'UserLoggingIncludeEvents = 1,2,3,4,6'. If not present
# then all events are enabled
# UserLoggingFilterEvents = 0,1,2,3,4,5,6,7
# Note: User logs can be found in /home/MasterControl/Jetty/webapps/root/UserLogs and are accessible by the
# user from a web browser at :8080/UserLogs e.g. 192.178.1.0:8080/UserLogs
STUDIO SETUP FILE - USER CONTROL LOGGING SECTION
CALREC Putting Sound in the Picture
97
Path Controls Logged
Memory save/load
Preset load
Preset copy
Preset Paste
Time change
CSCP Aux Send On
CSCP Fader Cut
CSCP Fader PFL
CSCP Fader Level
CSCP Input LB
CSCP Main Route
Fader copy/paste
Fader Open/Close
Fader Level (F)
Fader Shaft Level (F)
Fader Level default
Fader Level line-up
Downmix Level (F)
Downmix Shaft Level (F)
Downmix Level default
Fader AFL
Fader PFL
Fader Cut
Fader ext control
Fader rear AFL
Fader Sidechain Listen
Main Pre/Post Delay
Main Routing
Group Pre/Post Delay
Group Routing
Width Control (F)
Width In
Pan Centre Only
Front Back Pan (F)
Front Back Pan In
Front Pan Divergence (F)
Front Pan Divergence In
Front LR Pan (F)
Front Pan In
Front Pan LCR
Pan Joystick Active
Pan LFE Level (F)
Pan LFE In
Pan Non-LFE Level (F)
Pan Non-LFE In
Pan Bypass
Pan Front Format
Pan Mono
Pan Rotate (F) (U)
Pan Rotate In (U)
Rear Pan Divergence (F) (U)
Rear Pan Divergence In (U)
Rear LR Pan (F)
Rear Pan In
Rear LCR Pan (U)
Mix Minus AFL
Mix Minus Level (F)
Mix Minus Talkback
Mix Minus Tone
Output Delay Assign
Output Delay In
Output Delay Time (F)
Input Balance (F)
Input RB
Input LB
Input Leg Routing LBRB
Input MS
Input Patch (disabled)
Input Select
Input Tone
Input Trim
Input Trim Link
Master Input Gain
Master Nudge Input Gain
Master Input Phantom Power
Master Input Phantom Power Left
Master Input Phantom Power Right
Master Input SRC
Master Input SRC Left
Master Input SRC right
Master Input Phase Reverse
Master Input Phase Rev Left
Master Input Phase Rev Right
Mono Input Gain
Mono Nudge Input Gain
Mono Input Phantom Power
Mono Input Phantom Power Left
Mono Input Phantom Power Right
Mono Input SRC
Mono Input SRC Left
Mono Input SRC Right
Mono Input Phase Reverse
Mono Input Phase Rev Left
Mono Input Phase Rev Right
Input Delay Assign
Input Delay In
Input Delay Time (F)
Input Delay Nudge (F)
Insert Allocate
Insert In
Insert Position
Direct Output AFL
Direct Output Apply Spill
Direct Output Defeat Downmix
Direct Output Delay In
Direct Output Delay Time (F)
Direct Output Level (F)
Direct Output Mix Minus Bus
Direct Output Mix Minus On
Direct Output MM Position
Direct Output OPL
Direct Output Position
Direct Output Talk Back
Direct Output Tone
Track Send Position
Track Route All
Track Send Routing
Track Send Apply Spill
Track Send Defeat Downmix
Track Send Level (F)
Track Send Split
Path Delay In
Path Delay Time (F)
Path Delay Position
98 ARTEMIS Digital Broadcast Production Console
Setup & Configuration
Aux Send Position
Aux Send Routing
Aux Send apply spill
Aux Send Defeat Downmix
Aux Send Level (F)
Aux Route All
Dyn Automixer In
Dyn Automix Link
Dyn Bypass
Dyn Comp Auto
Dyn Comp In
Dyn Compressor Active
Dyn Comp Sidechain Iso
Dyn Soft Attack
Dyn Control Independence
Dyn Automix Disable
Dyn Exp Gate Auto
Dyn Exp Gate Fast Attack
Dyn Exp Gate In
Dyn Exp Ratio 2:1/Var
Dyn Exp Gate Sidechain Iso
Dyn Follow Primary
Dyn Gate
Dyn Key Input (U)
Dyn Key Invert (U)
Dyn Link
Dyn Link Independence
Dyn Link Select
Dyn Primary Position
Dyn Secondary Position
Dyn Sidechain Listen
Dyn Automix Link Select (F)
Dyn Automix Weight (F)
Dyn Comp Attack (F)
Dyn Comp Knee (F)
Dyn Comp Ratio Fine (F)
Dyn Comp Ratio (F)
Dyn Comp Recovery (F)
Dyn Comp DSP Threshold (U) (F)
Dyn Comp Threshold (F)
Dyn Automix Attack (F)
Dyn Automix Recovery (F)
Dyn Exp Gate Attack (F)
Dyn Exp Gate Recovery (F)
Dyn DSP Threshold (U) (F)
Dyn Threshold (F)
Dyn Gate Delay (F)
Dyn Gate Depth (F)
Dyn Link Select (F)
Dyn Make Up Gain (F)
Direct Input Patch (disabled) (U)
Direct Input On (U)
Direct Input Level (F) (U)
External Input Patch (disabled) (U)
Auto Minus Position (U)
Auto Minus Routing (U)
Auto Minus Apply Spills (U)
Auto Minus Defeat Downmix (U)
All EQ In
EQ Alt = Normal
EQ Alternate
EQ Bypass
EQ Dyn Selected
EQ Reset
EQ In
EQ Independence
EQ Level (F)
EQ A = EQ B
EQ Q (F)
EQ Response
EQ Response Type (F)
EQ Frequency (F)
Delay Popup Coarse Up (F)
Delay Popup Coarse Down (F)
Tone In
CALREC Putting Sound in the Picture
99
User Logs
The logging files are written to:----------->
These logs can be found on each of
the MCS cards and in order to view the
files the user can access them via a
Web-Browser at the following address:-
:8080/UserLogs
where the MCS IP address can be found
from Program Updater so in this example:-
192.178.1.0:8080/UserLogs
Once accessed the directory of user logs
appears as shown right:
The logs are saved as .txt files and has
a naming convention that allows easy
sorting of oldest to newest:---------------->
e.g. if started at 30th September 2015 at
15:14:39 then this becomes:
150930_151439_UserControlLog.txt
Once the selected log has been accessed
the data appears as a formatted
table showing Date, Time, Event Type,
Layer-Fader Number Sub Layer, Label,
Control and Value all ordered by earliest
timestamp first as shown right:
The table can then be searched and
analysed to find out the sequence of
events that occurred around the time of
interest.
/home/MasterControl/Jetty/webapps/root/UserLogs
_UserControlLog.txt