Detecto DL Series Operation Manual
Read Online
Read the Detecto DL Series Operation Manual online using the built-in PDF viewer.
Text of the manual
8529-0637-2M Rev A DL Series Operation Manual
1
DL Series
Price Computing Scale
with Integral Printer
Operation Manual
8529-0637-2M Rev A
203 E. Daugherty, Webb City, MO 64870 USA
11/15
Ph: 417-673-4631 Fax: 417-673-5001
www.detecto.com
Technical Support: Ph: 866-254-8261 [email protected]
8529-0637-2M Rev A DL Series Operation Manual
3
INTRODUCTION
Thank you for purchasing our Detecto DL Series Price Computing Scale with Integral Printer.
Your scale has been designed to operate from 115 VAC 50/60 Hz.
This manual will guide you through setup and operation of your scale. Please read it
thoroughly before attempting to operate this scale and keep it handy for future reference.
COPYRIGHT
All rights reserved. Reproduction or use, without expressed written permission, of editorial or
pictorial content, in any manner, is prohibited. No patent liability is assumed with respect to the
use of the information contained herein.
DISCLAIMER
While every precaution has been taken in the preparation of this manual, the Seller assumes
no responsibility for errors or omissions. Neither is any liability assumed for damages resulting
from use of the information contained herein. All instructions and diagrams have been checked
for accuracy and ease of application; however, success and safety in working with tools
depend to a great extent upon the individual accuracy, skill and caution. For this reason the
Seller is not able to guarantee the result of any procedure contained herein. Nor can they
assume responsibility for any damage to property or injury to persons occasioned from the
procedures. Persons engaging the procedures do so entirely at their own risk.
SERIAL NUMBER _____________________
DATE OF PURCHASE _________________
PURCHASED FROM __________________
____________________________________
____________________________________
RETAIN THIS INFORMATION FOR FUTURE USE
PRECAUTIONS
Before using this product, read this manual and pay special attention to all
"NOTIFICATION" symbols:
.
IMPORTANT
.
ELECTRICAL
WARNING
.
STATIC
SENSITVE
I
8529-0637-2M Rev A DL Series Operation Manual
4
PROPER DISPOSAL
When this device reaches the end of its useful life, it must be properly disposed of. It must not
be disposed of as unsorted municipal waste. Within the European Union, this device should
be returned to the distributor from where it was purchased for proper disposal. This is in
accordance with EU Directive 2002/96/EC. Within North America, the device should be
disposed of in accordance with the local laws regarding the disposal of waste electrical and
electronic equipment.
It is everyone’s responsibility to help maintain the environment and to reduce
the effects of hazardous substances contained in electrical and electronic
equipment on human health. Please do your part by making certain that the
device is properly disposed of. The symbol shown to the right indicates that
this device must not be disposed of in unsorted municipal waste programs.
FCC COMPLIANCE STATEMENT
This equipment generates, uses and can radiate radio frequency and if not installed and used
in accordance with the instruction manual, may cause interference to radio communications. It
has been designed within the limits for a Class A computing device pursuant to Subpart J of
Part 15 of FCC rules to provide reasonable protection against such interference when
operated in a commercial environment. Operation of this equipment in a residential area may
cause interference in which case the user will be responsible to take whatever measures
necessary to correct the interference.
You may find the booklet "How to Identify and Resolve Radio TV Interference Problems"
prepared by the Federal Communications Commission helpful. It is available from the U.S.
Government Printing Office, Washington, D.C. 20402. Request stock No. 001-000-00315-4.
II
8529-0637-2M Rev A DL Series Operation Manual
5
TABLE OF CONTENTS
SPECIFICATIONS 1
ABREVIATIONS AND GLOSSARY 2
INSTALLATION 3
Attachment of Tower Display 3
Placement 3
Level Adjustment 3
Power Connection 3
PRINTER 4
Install Gap Labels 4
Gap Paper Mounts Recycle 6
Install Plain Paper 6
Operations Concerning Paper 7
Abnormity of Gap Paper Print 7
KEYPAD FUNCTIONS 8
DISPLAY ANNUNCIATORS 12
Tare (lb) Window 12
Weight (lb)/Pcs Window 12
Change ($)/Unit $/lb Window 12
Total Price ($) Window 13
Dot Matrix Display 13
OPERATION INDICATORS 14
SET DATE, TIME AND STORE NAME 15
FAST PLU PROGRAMMING 16
QUICK KEY PROGRAMMING 17
OPERATION 18
Basic PLU Transaction 18
By Weight 18
By Count 18
Tare 18
Weight Tare 18
Keypad Tare 19
Lock and Unlock Tare 19
Batch Print Mode (only for piece count PLU) 20
Pre-Pack Mode (only for weight PLU) 20
Temporary-Sale by Weight 21
Temporary-Sale by Count 21
Price Discount by Subtraction 21
III
8529-0637-2M Rev A DL Series Operation Manual
6
TABLE OF CONTENTS, CONT.
REPORT PRINTING OPERATION 22
Print Total Report 22
Print PLU Report 23
Clear Report Information Manually 24
Clear All Reports and Records Information 24
PRINT FORMAT 25
BARCODE PRINTING 26
ERROR CODES 27
CARE AND CLEANING 29
IV
8529-0637-2M Rev A DL Series Operation Manual
1
SPECIFICATIONS
Models:
DL1030, DL1030P
Capacity
30 lb (15kg)
Division Value:
0 – 30 lb x .01 lb (0 – 15 kg x .005 kg)
Platform Size:
L x W = 12.8 x 8.9 in (324 x 226 mm)
Scale Size:
Integrated Rear Display
With Tower Display
L x W x H = 15.6 x 13.8 x 6.2 in (396 x 351 x 158 mm)
L x W x H = 17.6 x 13.8 x 18.3 in (448 x 351 x 464 mm)
Display:
4 Window LED display 1 Dot matrix Text screen
LED Display:
4 digits for tare
5 digit for weight,
6 digit for unit price
6 digit for total price
Power:
20VDC, 4A with positive center, AC adaptor
Operating Temperature:
32 ~ 104°F (0° ~ 40°C)
Printer:
Thermal Print
Print Media:
58mm x 40mm and 40mm x 30mm gap thermal paper
58mm and 40mm width plain thermal paper
PLU:
5990
8529-0637-2M Rev A DL Series Operation Manual
2
ABREVIATIONS AND GLOSSARY
PLU
Price or Product Look Up. e.g. Identification number affixed to produce
and other products
Weight PLU
By Weight PLU
Count PLU
By Count PLU
Dept.
Department
U. Price
Unit price
T. Price
Total Price
Prog
Program key or menu
F Prog
Fast program key or menu
Spec
Specification. Parameter that control the behavior of the scale
T-Sale
Temporarily Sale
Amount
The quantity of the goods, weight or count. It means weight (lb) for
weight PLU and count (pcs) for count PLU
8529-0637-2M Rev A DL Series Operation Manual
3
INSTALLATION
Included in carton find:
Scale
Tray - 2 pcs: plastic tray & metal top
Display pole and screw pack (DL1030P only)
Operation Manual
DL Series Setup Utility CD
Four (4) overlays for shortcut PLU
Power Cord
Attachment of Tower Display
Remove cover tower bracket on bottom of base. Place the tower display in close proximity to
the base. Connect tower cable to circuit board in base. Gently slide the tower post into the
bracket. Fasten the tower to base with two bolts provided. Replace bracket cover.
Placement
Place the scale in an environment free of excessive dust and moisture and on a stable,
vibration-free level surface away from direct sunlight and any rapidly moving air source
(heating/cooling vents, fans, etc.). This will prevent sudden temperature changes and air
currents that may result in unstable weight readings.
WARNING! DO NOT place the scale on any unstable cart, stand or table. The scale
may fall causing injury to the operator, and damage the unit, or proper operation of
the scale may be inhibited.
Level Adjustment
Check to make certain the scale is level. The level indicator is located at the front of the scale.
If the scale is not level (the bubble will not be centered), adjust the mounting feet as required to
center the bubble and attain a level scale.
Power Connection
The scale uses an external AC power cord that is to be used in a standard 110/120 VAC
50/60Hz grounded wall outlet.
8529-0637-2M Rev A DL Series Operation Manual
4
PRINTER
Install Gap Labels
1.Open Upper door
Step 1 - Open door of scale printer
Step 2 - Remove paper retainer
Step 3 - Paper through
8529-0637-2M Rev A DL Series Operation Manual
5
PRINTER, CONT.
Step 4 - Paper path
Step 5 - Finish paper install
11.Cover door
12.Press【Feed】
Step 6 - Close door of scale printer
8529-0637-2M Rev A DL Series Operation Manual
6
PRINTER, CONT.
Gap Paper Mounts Recycle
Pull out spring
Step 7 - Gap paper mounts recycle
Install Plain Paper
Different from the way in installing gap paper shown. U-shaped paper retaining spring is not
needed anymore. All you need to do is to put the paper into the paper sensor and let the tear
part be outside.
8529-0637-2M Rev A DL Series Operation Manual
7
PRINTER, CONT.
Operations Concerning Paper
【Paper Type】: Make sure the type of paper set is the same as the type used. When
〖Gap Paper〗is light in the display, you should set to use gap paper. Otherwise you
should set to use plain paper. If the type of paper you set to use is different from the
type currently used, please long press 【Paper Type】to change the set.
【Feed】: After installing the paper, press【Feed】. You can also press 【Feed】 to
clear abnormities of the printer and make paper roll for a certain length.
Abnormity of Gap Paper Print
Users of plain paper don’t do any adjustment for this.
Abnormity of printer parameters may happen when gap paper prints are abnormal, paper goes
out continuously, or printer can’ work after one paper is printed, printing parameter maybe have
abnormity
Users need to check if paper type is right first. Then users could follow these operations below
to eliminate malfunctions:
Install gap paper, and make the edge of gap paper not exceed print head. (Not block the
paper-out sensor)
Paper-Out sensor
Switch off the scale. Press the 【Feed】key then switch on the scale, hold this key until
finished self-checking and go into work interface
Printer would roll out the paper at the length of 50mm. automatically
After the paper is rolled out, malfunctions have been eliminated if without any warning. If
alarm E7.10 means calibration abnormity, pls try again after confirming the sticker
perper has been used.
Then, press 【Feed】to print the test page
Go to normal operation processes.
8529-0637-2M Rev A DL Series Operation Manual
8
KEYPAD FUNCTIONS
DL1030 Keypad and Front Display
DL1030 Rear Display
8529-0637-2M Rev A DL Series Operation Manual
9
KEYPAD FUNCTIONS, CONT.
DL1030P Keypad
DL1030P Display
8529-0637-2M Rev A DL Series Operation Manual
10
KEYPAD FUNCTIONS, CONT.
Key
Function
Sale
Enter sale mode and execute the operation of goods sale.
Prog
Enter program mode to program parameters, PLU, print formats, time, etc.
Account
Print
Enter Account mode to inquire about transaction data or print reports and so
on.
Time
Display current time and return to the previous interface when you press it
again.
Feed
Press this key to feed gap thermal paper and plain thermal paper through the
printer. Unprinted buffer data will be cleared in the process of feed.
F-Prog
Quick access to changing setting and values of PLU’s in sales mode. It is
always used for combination of keys, which is similar to F keys of a PC
keyboard. Please refer to process instructions to understand the use of
combination keys.
Shift
Used for extending PLU shortcut key, and switching case sensitivity in text
input interface.
Pre-Pack
These keys allows you to switch between other sales modes. If the current sale
buffer is empty, the user can long-press these keys to reenter sales mode
selected.
Lock PLU
Auto Print
Batch Print
Zero
Clear current weight and reset to zero within allowed range.
-NUM
Discount in subtraction.
Paper
Type
Press for 4 seconds to switch between gap thermal paper and plain thermal
paper.
@ Price
Used to override the unit price of the PLU. When spec 083 is active, modified
price will be saved.
T-Sale
Set input number as Unit Price and set a temporary PLU. You can amend the
temporary weight PLU’s unit in Spec
Re-
print
Repeat last print in current buffer (Repeated print data would not be stored in
deal records as sale record.). This function can be forbidden in Spec.
Tare
Manually enter and remove Tare.
8529-0637-2M Rev A DL Series Operation Manual
11
KEYPAD FUNCTIONS, CONT.
Key
Function
0 – 9, 00
Numerical keys to input corresponding numbers.
X
Input count amount in count sale or do temporary count goods sale according
to input U.Price.
Amend
Amend transaction data in sale interface and store amended data in the
program interface.
V1-V4
(Arrows)
Activate corresponding sale buffers.
Switch among sequential steps and numbers in the program and account
interfaces.
PLU
When you type a PLU number and press this key, it will call up that PLU
Print
Print labels or receipts according to setting
Back
Delete the last input data. Return to previous step without saving.
Cancel
Clear data, cancel operations or go back to previous step
Accu
/Confirm
Save accumulative transaction data into activated sale buffer and other
confirmation operations.
SP
Input a Space when entering characters.
End
End character, all characters after cursor are deleted
Del
Delete the character at position of cursor
Insert
Enter into insert mode. Insert mode is activated when cursor is flashing
IME
Input method editor. Switch the input languages: En-1(in small letters), En-2 (in
big letters), press accumulate to confirm
8529-0637-2M Rev A DL Series Operation Manual
12
DISPLAY ANNUNCIATORS
Tare (lb) Window
Annunciator
Function
Auto
Mode
Is turned on to indicate auto mode. When in auto mode, lock PLU will
active. In this mode, pre-pack or batch print is executed based on
Spec078 and Spec079.
Gap
Paper
Is turned on when paper type is gap paper. It is off when paper type
is plain paper.
Lock
Tare
Is turned on when tare is locked. Long press 【Tare】 would lock
tare. Under this condition, tare would not be cleared after the sale.
Long press 【Tare】 again would exit lock tare.
Lock
PLU
Is turned on when PLU is locked. Long press 【PLU】 would lock
PLU. Under this condition, former PLU sale state would remain the
same after the sale. And it will last until new PLU is transferred. Long
press 【PLU】 again would exit lock PLU.
Weight (lb)/Pcs Window
Annunciator
Function
0
Zero weight annunciator – Is turned on when weight is at zero and
stable
Manual
Weight
Is turned on when manual weight is displayed.
Stable weight indicator – Is turned on when weight is stable
NET
Net weight indicator
Shift
Is turned on when 【Shift】 key is pressed.
Change ($)/Unit Price $/lb Window
Annunciator
Function
Sale
Indicates Scale is in Sale Mode
Prog
Is turned on when in Program Mode
Account
Is turned on when in Account Mode
Change
Is turned on to indicate the data in Change($)/Unit Price $/lb window
is displayed as change.
Unit
Price
Is turned on to indicate the data in Change($)/Unit Price $/lb window
is displayed as goods U.Price.
8529-0637-2M Rev A DL Series Operation Manual
13
DISPLAY ANNUNCIATORS, CONT.
Total Price ($) Window
Annunciator
Function
V1 ~ V4
Is turned on when there are buffers in V1~V4 records. Will be flashing
when in edit mode.
Discount
To display single means that current goods has been discounted in
U.Price; To display total means that current accumulative total has
been discounted in T.Price
Single
Is turned on when total price of current goods is displayed in Total
Price($) window
Sum
Is turned on when the sum total price of current sale buffers (V1~V4)
is displayed in Total Price($) window
Dot Matrix Display
Dl103P units have an additional 160×32 dot matrix LCD display. It displays time or ad-
message or accumulation record in idle mode; and displays PLU’s name in PLU mode.
8529-0637-2M Rev A DL Series Operation Manual
14
OPERATION INDICATORS
Key Notation
【】denotes Key
〖〗denotes Display Annunciator
【F-Prog】+【PLU】.indicates press keys 【F-Prog】and【PLU】same time.
【1】【0】 【】indicates press key 【1】then press 【0】then press 【】
Audible Signals
1 Short beep
Confirm key press
1 Long beep and 2 Short
Beeps
Indicates incorrect key press
Repetitive short beeps
Error, scale will display error code Ex.xx
2 Beeps (Long key press)
Confirms long key press
Character Reference
Number Characters 0~9
Characters A~M
Characters N~Z
Dash, under line, above line, three lines of special symbols
8529-0637-2M Rev A DL Series Operation Manual
15
SET DATE, TIME AND STORE NAME
Set Time & Date
Scale State /
Operation
Key
Display
Comment
Tare
Weight /
Pcs
Change /
Unit Price
Total
Idle
【Prog】
【1】
【1】.
F23
PLU.00
noSEt
0
〖Prog〗on
Move cursor to
display position to be
changed
【 V2】
【V4】
Use Number keys to
enter time & date
【0】-
【9】
Save settings
【Amend
】
Return to normal
operation
【Sale】
Program Store Name
Scale State /
Operation
Key
Display
Comment
Tare
Weight /
Pcs
Change /
Unit Price
Total
『Sale Idle』
0.000
0.000
0.00
0.00
〖Sale〗, 〖Sum〗on.
Enter program
【Prog】
P1
TMSet
〖Prog〗on.
Enter TMSet
【1】
P11
TMSet
Time
Enter String
【3】
P13
ST.000
ShopN
Push-OK
ST.000 is store name.
String No.
String Info
Switch to device name
【→】
P13
ST.001
ScaleN
Push-OK
ST.001 is device name.
Switch to store name
【←】
P13
ST.000
ShopN
Push-OK
Enter editing
【Confirm】
EN-1
0
Clear original text
【End】
EN-1
0
In view of have original
text, Suggesting users
press 【End】 before
editing to clear former
text.. If modify on
original literal, use
【】【】to move
cursor to target position
Switch to EN-2
【Switch】
EN-2
0
0
Save editing text
【Amend】
P13
PLU.14
Name
OK-Edit
Save to the scale.
Return to sale mode
【Sale】
0.000
0.000
0.00
0.00
〖Sale〗, 〖Sum〗 on.
8529-0637-2M Rev A DL Series Operation Manual
16
FAST PLU PROGRAMMING
Fast Programming of PLU
Scale State /
Operation
Key
Display
Comment
Tare
Weight /
Pcs
Change /
Unit Price
Total
Enter program mode
Press F-Prog + PLU
at same time
【F-Prog】+
【PLU】.
F23
PLU.00
noSEt
0
〖Prog〗on
Enter PLU
Press right arrow
【1】【0】.【】.
F23
PLU.00
noSEt
10
Enter item code
Press right arrow
【1】【2】【3】【4】
【】.
F23
PLU.01
Icode
1234
Enter unit of
measure: weight or
count
Press right arrow
【1】 【】.
F23
PLU.03
Unit
1
0, 1 = Default
weight lb.
6 = Weight lb.
2 = Piece Count
Enter unit price
Press right arrow
【2】【5】【0】
【】.
F23
PLU.04
Price
2.50
Tare
【】.
F23
PLU.06
PLU name
F23
PLU.14
Name
OK-Edit
Enter Text edit mode
【Accu/Confirm】
En-1
0
Note:
Press 【IME】.Input-Method-Edit to switch input type
En-1 Lowercase
En-2 Uppercase
UTF-8
ISN Code
Enter PLU Name
using Alpha-Numeric
Keys
【A】-【Z】..
【0】-【9】..
Press【Shift 】
to change letter
case
Example
【A】【p】【p】【l】
【e】
Save PLU Name
Press right arrow
【Amend】
【】.
Shelf Date Print
Press right Arrow
【0】.or 【1】.
【】.
F23
PLU.26
PS-Ud
1
O= No, 1= Yes
If Shelf Date Print
Yes
Enter Shelf Days
using numeric keys
【1】-【9】.
F23
PLU.31
PC-Ud
X
Where X=
number of days
entered
Save PLU
【Amend】
F23
PLU.00
noSEt
0
8529-0637-2M Rev A DL Series Operation Manual
17
QUICK KEY PROGRAMMING
Programming of Quick Key
【QK】 denotes the Quick Key to be programmed such as .
Scale State /
Operation
Key
Display
Comment
Tare
Weight /
Pcs
Change /
Unit Price
Total
Enter Quick Key
Program Mode
【F-Prog】+
【QK】.
F14
SCPLU
1-01
1
Enter PLU
【1】【0】.
F14
SCPLU
1-01
10
Save
【Amend】
F14
SCPLU
a/A
8529-0637-2M Rev A DL Series Operation Manual
18
OPERATION
Basic PLU Transaction
By Weight.
Scale State /
Operation
Key
Display
Comment
Tare
Weight /
Pcs
Change /
Unit Price
Total
Idle
0.00
0.000
0.00
0.00
Place goods on scale
0.00
2.00
0.00
0.00
Enter PLU
Press PLU
【1】【0】.
【PLU】.
0.00
2.000
2.50
5.00
Print Label
【Print】.
0.00
2.000
0.00
0.00
Remove goods
0.00
0.00
0.00
0.00
By Count
Scale State /
Operation
Key
Display
Comment
Tare
Weight /
Pcs
Change /
Unit Price
Total
Idle
0.00
0.000
0.00
0.00
Enter PLU
Press PLU
【1】【2】.
【PLU】.
0.00
0.00
1.00
1.00
Enter PLU quantity
【X】.【5】.
0.00
5
1.00
5.00
Print Label
【Print】.
0.00
0.00
0.00
0.00
Tare
Weight Tare
Examples show tare of container weighing 0.25 lb.
Scale State /
Operation
Key
Display
Comment
Tare
Weight /
Pcs
Change /
Unit Price
Total
Idle
0.00
0.000
0.00
0.00
Place container on
scale
0.00
0.25
0.00
0.00
Press Tare
【Tare】
0.25
0.00
0.00
0.00
Tare on
Note: With all weight removed, press Tare key again to cancel
Tare off
8529-0637-2M Rev A DL Series Operation Manual
19
OPERATION, CONT.
Keypad Tare
Scale State /
Operation
Key
Display
Comment
Tare
Weight /
Pcs
Change /
Unit Price
Total
Idle
0.00
0.000
0.00
0.00
Enter Tare weight
using numeric keys
【2】【5】
0.00
0.25
0.00
0.00
Press Tare
【Tare】
0.25
-0.25
0.00
0.00
Tare on
Note: Weight will show negative until container placed on scale
Note: With all weight removed, press Tare key again.to cancel
Tare off
Lock and Unlock Tare
Lock Tare and Unlock Tare
Operations
Keys
Display
Comment
Tare
Weight /
Pcs
Change/
Unit Price
Single/
Total
Lock tare
Long Press
【Tare】
〖Lock Tare〗 on
Other operations
Unlock tare
Long Press
【Tare】
〖Lock Tare〗 off
Note 1 When you long press 【Tare】, you can hear one beep first (beep for correctness or
error). Hold pressing for 4 seconds you will hear the beep for correctness.
Note 2 Once tare locked, it cannot be changed or cleared automatically.
Note 3 Only manual tare can change tare. If a PLU has PLU Tare, Lock Tare cannot
overwrite PLU tare.
Note 4 Once tare locked, it cannot be unlocked unless users unlock tare manually.
8529-0637-2M Rev A DL Series Operation Manual
20
OPERATION, CONT.
Batch Print Mode (only for piece count PLU)
Example PLU11 is weight PLU with Unit Price $2.00/pc
Operations
Keys
Display
Comment
Tare
Weight /
Pcs
Change/
Unit Price
Single/
Total
『Sale Idle』
0.000
0.000
0.00
0.00
〖Sale〗, 〖Sum〗on.
Enter batch print
mode
【Batch Print】
0.000
0.000
0.00
0.00
〖Auto Mode〗on
Transfer PLU11
【1】【1】【PLU】
5.00
5.00
〖Unit Price〗,
〖Single〗on.
Input quantity
【×】【5】
5
5.00
25.00
If quantity is 1, omit
this step
Confirm sale object
【Print】
Input
Count
0
Input the number of
print copies
【5】
Input
Count
5
Confirm the number 【Accu/Confirm】
Print 5 copies
Press 【Cancel】 to
exit print in midway.
Print ends
5
5.00
5.00
Exit quantity input
5.00
25.00
Exit Batch Print
【Batch Print】
0.000
0.00
0.00
0.000
〖Auto Mode〗off.
Pre-Pack Mode (only for weight PLU)
Example PLU10 is weight PLU with Unit Price $2.00/lb.
Operations
Keys
Display
Comment
Tare
Weight /
Pcs
Change/
Unit Price
Single/
Total
『Sale Idle』
0.000
0.000
0.00
0.00
〖Sale〗, 〖Sum〗on.
Enter prepack mode
【Pre-Pack】
0.000
0.000
0.00
0.00
〖Auto Mode〗,
〖Lock PLU〗on
Transfer PLU10
【1】【0】
【PLU】
0.000
0.000
2.00
0.00
〖Unit Price〗,
〖Single〗on.
Put goods PLU10 on
0.000
0.900
2.00
1.80
After weight is stable.
0.000
0.900
0.00
1.80
Print automatically.
Take goods PLU10 off
0.000
0.000
0.00
0.00
Put goods PLU10 on
0.000
1.900
2.00
3.80
After weight is stable.
0.000
1.900
0.00
0.00
Print automatically.
Take goods PLU10 off
0.000
0.000
0.00
0.00
Exit PLU
【Cancel】
〖Sum〗 on.
Exit Auto Mode
【Pre-Pack】
〖Auto Mode〗,
〖Lock PLU〗off.
8529-0637-2M Rev A DL Series Operation Manual
21
OPERATION, CONT.
Temporary-Sale by Weight
Operations
Keys
Display
Comment
Tare
Weight/
Count
Change/
Unit Price
Single/
Total
『Sale Idle』
0.000
0.000
0.00
0.00
〖Sale〗, 〖Sum〗 on.
Input Unit Price
【1】【3】【0】
0.000
0.000
1.30
0.00
Set as a temporary
weight PLU,
【T-Sale】
0.000
0.000
1.30
0.00
〖Unit Price〗,
〖Single〗 on.
Clear current PLU
【Cancel】
0.000
0.000
0.00
0.00
〖Sum〗 on.
Temporary-Sale by Count
Operations
Keys
Display
Comment
Tare
Weight/
Count
Change/
Unit Price
Single/
Total
『Sale Idle』
0.000
0.000
0.00
0.00
〖Sale〗, 〖Sum〗 on.
Input Unit Price
【1】【7】【0】
0.000
0.000
0.85
0.00
Set as a temporary
count PLU
【×】【2】
2
0.85
1.70
〖Unit Price〗,
〖Single〗 on.
Clear current PLU
【Cancel】
0.000
0.000
0.00
0.00
〖Sum〗 on.
Price Discount by Subtraction
Operations
Keys
Display
Comment
Tare
Weight/
Count
Change/
Unit Price
Single/
Total
『Sale Idle』
0.000
0.000
0.00
0.00
〖Sale〗, 〖Sum〗on.
Transfer PLU10
【1】【0】
【PLU】
0.100
-0.100
2.00
0.00
〖Unit Price〗,
〖Single〗on.
Input discount data
【1】【0】
0.100
-0.100
0.10
0.00
Discount in
subtraction
【-Num】
0.100
-0.100
1.90
0.00
〖Discount〗on.
Clear current PLU
【Cancel】
0.000
0.000
0.00
0.00
〖Sum〗 on.
8529-0637-2M Rev A DL Series Operation Manual
22
REPORT PRINTING OPERATION
Print Total Report
Total reports are divided into total daily report, total monthly report, total quarterly report and total
manual report. Each report owns 32 buffer zones (0~31).
Take total daily report as an example: The buffer zone 0 stores total daily report of current day; buffer
zone 1 stores total daily report of the last day. The rest may be deduced by analogy. So buffer zone 31
stores total daily report of the day dating back to 31 days ago.
Total monthly report and total quarterly report works in the same way, storing total report of the last x
months or quarters (x=0~31).
Total manual report would take operation A51 as time point to divide the storage. The buffer zone
delays a position automatically when a report is cleared (That means: Buffer 31 records the information
which was stored in buffer 30. By analogy, buffer 1 record the information which was stored in buffer 0
and information stored in buffer 0 is cleared. Then start accumulating in buffer 0. ).
When printing total report, system would request to input 2 numbers. And the scale would print total
buffer which is added up with the buffers whose numbers are between the 2 input numbers.
Print Daily Reports of Today and Yesterday
Operations
Keys
Display
Remarks
Tare
Weight/
Count
Change/
U.Price
Single/
Total
『Sale Idle』
0.000
0.000
0.00
0.00
〖Sale〗, 〖Sum〗 on.
Enter Account
【Account】
A1
Total
〖Account〗 on.
Enter total report
【1】
A11
Total
Daily
【1】: Total report
【2】: Dept. report
【3】: Class report
【4】: PLU report
Enter total daily report
【1】
Input
2 – 1
0
【1】: Daily report
【2】: Monthly report
【3】: Quarterly report
【4】: Manual report
Input start number
【0】
【Confirm】
Input
2 – 2
0
Start from today.
Input end number
【1】
【Confirm】
…
…
…
…
End at yesterday.
A11
Total
Daily
0
Print daily report of
today. (Note 4)
A11
Total
Daily
1
Print daily report of
yesterday. (Note 4)
A11
Total
Daily
End of print.
Return to sale mode
【Sale】
0.000
0.000
0.00
0.00
〖Sale〗, 〖Sum〗 on.
Note 1 If some buffers store no data, these buffers would be skiped off without printing.
Note 2 If end number input is 0, system would only print the buffer appointed by start number.
Note 3 If end number input is not 0 and less than start number, no buffer would be printed.
Note 4 The hints about currently print object may appear on the screen for just a few moment when
system is printing.
8529-0637-2M Rev A DL Series Operation Manual
23
REPORT PRINTING OPERATION, CONT.
Print PLU Report
The scale could print PLU reports whose number is less than 1000.
When printing PLU reports, system would orderly print those PLU reports whose serial numbers is
between the 2 input numbers as well as the 2 input numbers.
Print PLU Daily Reports with the Numbers from 10 to 20
Operations
Keys
Display
Remarks
Tare
Weight/
Count
Change/
U.Price
Single/
Total
『Sale Idle』
0.000
0.000
0.00
0.00
〖Sale〗, 〖Sum〗 on.
Enter Account
【Account】
A1
Total
〖Account〗 on.
Enter PLU report.
【4】
A41
PLU
Daily
【1】: Total report
【2】: Dept. report
【3】: Class report
【4】: PLU report
Enter PLU daily report
【1】
Input
2 – 1
0
【1】: Daily report
【2】: Monthly report
【3】: Quarterly report
【4】: Manual report
Input start number
【1】【0】
【Confirm】
Input
2 – 2
0
Start from PLU10.
Input end number
【2】【0】
【Confirm】
…
…
…
…
End to PLU20.
10
Print
Print
daily
report
of
PLU10.
11
Print
Print
daily
report
of
PLU11.
…
Print
End of print.
Return to sale mode
【Sale】
0.000
0.000
0.00
0.00
〖Sale〗, 〖Sum〗 on.
Note 1 If some buffers store no data, these buffers would be skiped off without printing
Note 2 If end number input is 0, system would only print the buffer appointed by start number.
Note 3 If end number input is not 0 and less than start number, no buffer would be printed.
8529-0637-2M Rev A DL Series Operation Manual
24
REPORT PRINTING OPERATION, CONT.
Clear Report Information Manually
The information in manual reports would not be cleared automatically unless users enter A51 (clear
current manual report) interface to clear it. After this operation, manual reports of all departments,
classes and PLU would be cleared, and total manual report would delay its serial number.
Clear Information in Manual Report
Operations
Keys
Display
Remarks
Tare
Weight/
Count
Change/
U.Price
Single/
Total
『Sale Idle』
0.000
0.000
0.00
0.00
〖Sale〗, 〖Sum〗 on.
Enter Account
【Account】
A1
Total
〖Account〗 on.
Enter clear report
【5】
A51
Clear
Manly
Clear manual report
【1】
----
-----
------
-------
Wait a few seconds.
A51
Clear
Manly
Return to sale mode
【Sale】
0.000
0.000
0.00
0.00
〖Sale〗, 〖Sum〗 on.
Clear All Reports and Records Information
Clear All Reports and Records Information
Operations
Keys
Display
Remarks
Tare
Weight/
Count
Change/
U.Price
Single/
Total
『Sale Idle』
0.000
0.000
0.00
0.00
〖Sale〗, 〖Sum〗 on.
Enter Account
【Account】
A1
Total
〖Account〗 on.
Enter clear report
【5】
A51
Clear
Manly
Clear manual report
【2】
Input
Code
0
Input validate code.
Input validate code
【9】【9】【5】
【8】
Confirm validate code
【Confirm】
----
-----
------
-------
A52
Clear
All
Return to sale mode
【Sale】
0.000
0.000
0.00
0.00
〖Sale〗, 〖Sum〗 on.
Note 1 This operation would clear the records of all deals. And it’s irreversible. Please operate it
carefully.
8529-0637-2M Rev A DL Series Operation Manual
25
PRINT FORMAT
Paper Type: Press 【Paper Type】 for 4 seconds to switch between gap paper and plain
paper.
Format: There are 9 kinds of default print formats.
Label Size: 58mm x 40mm and 40mm x 30mm label, 58mm and 40mm width plain paper
are available in default print formats. When using different type of paper, please adjust the
corresponding Spec shown in the table below.
Paper type
Print type
Spec
Instructions
000
005
027
58mm x 40mm
gap paper
Label print
1
4
50
Default
Receipt print
7
7
50
Not recommend
40mm x 30mm
gap paper
Label print
2
5
36
Receipt print
8
8
36
Not recommend
58mm width
plain paper
Label print
1
4
50
Receipt print
7
7
50
40mm width
plain paper
Label print
2
5
36
Receipt print
8
8
36
Print formats include label print and receipt print. If user needs custom print format, please
use PC software to change or contact with appointed after-service center.
Don’t print bills while selling: amend Spec003 and Spec008 to 0. If some specific deals
need to print bills, please press 【Reprint】.
To print a few copies of one bill, put the amount into Spec003 and Spec008.
To print two different kinds of bills: set the type of bill 1 in Spec000~Spec009, and bill 2 in
Spec010~Spec019. Strongly suggest users contact with appointed after-service center.
Set grey level of gap thermal paper in Spec022.
Set grey level of plain thermal paper in Spec023.
Set plain thermal paper in Spec 025, the position for cut-off paper suggest Spec025 not
less than 30.
You can set different kinds of print formats and barcode types for each PLU. You can check
the details in PLU parameters for print formats and barcode types. Set the value of these
parameters to 0 if you choose the system type.
The procedures to confirm print format: take bill 1 as an example. If two or more goods are
sold, print sum bill and use Spec005 as print format. If only one good is sold, print the item
bill. If sale PLU has been set for a specific print format (not 0), system would use the print
format. If no specific print format has been set to sale PLU (The setting number is 0.), the
print format would be Spec000.
8529-0637-2M Rev A DL Series Operation Manual
26
BARCODE PRINTING
Can print various kinds of bar code, 9 kinds of default barcode settings.
Can scan inner code and external code.
Barcodes can be divided by use into item barcodes and total barcodes, which are printed in
item labels and total labels respectively.
Factory default barcodes support 5-digits total price and 6-digits total price. Please select
the barcode compatible with the POS
Goods Code
Digits
of Price
Spec
Suggestion
001
006
002
007
Flag Code
Using PLU No.
5
Default
1
7
xx
xx00000
x…is the flag code which is
reserved for scale in POS
system. User could define 0
as a MISC code for PLU
Number never equal to 0.
6
4
8
xx
xx0000
Flag Code
Using PLU
Item-Code
5
2
7
xx
xxyyyyy
x…is the flag code which is
reserved for scale in POS
system. y… is a MISC code
for total label. PLU’s Item-
Code is code in POS system.
6
5
8
xx
xxyyyy
No Flag Code
Using PLU
Item-Code
5
3
7
yyyyyyy
No flag code defined. y… is a
MISC code for total label.
PLU’s Item-Code is code in
POS system.
6
6
8
yyyyyy
Note 1 If users need special bar code format, please use PC suite or contact their
service center.
8529-0637-2M Rev A DL Series Operation Manual
27
ERROR CODES
Number
Alarm instructions
Methods to handle
E0.01
Weight is not stable when the scale
start-up.
Make sure there is no goods on the tray and the tray is
stable.
E0.02
Exceed the allowed start-up zero
range
Make sure there is no goods on the tray and the tray is on
the bracket.
E1.01
Prog data is invalid.
Input valid data again.
E1.03
The selected print format do not exist
Set print format again
E1.10
Sale at 0 price is forbidden.
The sale whose sell price is 0 is forbidden. Refer to
Spec070.
E1.11
Exceed the largest sale price.
Total price or grand total price of sold goods exceeds the
largest sale price.
E1.12
Need to return to zero point
Return to weight zero before sale. Refer to Spec069.
E1.13
Exceed accumulative limit
The accumulative times are over buffer accumulate limit
E1.14
There is data in buffer and cannot
print in single.
Print the data in buffers first. Then print this sale or switch
to other buffers.
E1.18
System cannot execute accumulative
operations while locking PLU.
Before accumulative operations, system needs to exit lock
PLU (or auto mode) first.
E1.19
System cannot switch buffers into
buffer with accumulation while locking
PLU.
Operate in current buffer, or exit lock PLU (or auto mode).
E1.21
Less than smallest sale weight
Weight needs to be larger than smallest sale weight.
E1.22
Larger than largest sale weight
Weight needs to be smaller than largest sale weight.
E1.23
Discounted Unit Price has to be less
than discount lower limit.
Discounted in allowed range, or amend the allowed range.
E1.24
Discounted Unit Price has to be
higher than discount upper limit.
E1.30
Cannot enter special sale mode
Selected PLU have conflict with special sale mode, select
again
E7.01
Some keys are pressed when the
scale starts.
Please confirm that no keys are pressed.
In this interface, the last window display pressed keys. 8-5
means the key in 8th column from the left and 5th row from
the top is pressed.
In this interface, the second window displays the calibrated
times.
8529-0637-2M Rev A DL Series Operation Manual
28
ERROR CODES, CONT.
Number
Alarm instructions
Methods to handle
E7.11
Gap paper is not taken away.
Take away the printed label paper. If there is still alarm this
problem, do as the way in chapter:
Abnormity of Gap Paper Print to detect.
E7.12
Print mouth is not closed tight.
Install the paper and close mouth.
E7.13
Printer is working.
Please wait for a few seconds and try again.
E7.14
Lack of plain paper
Reinstall plain paper or the paper type cannot match.
E7.15
Lack of gap paper
Reinstall label paper or the paper type cannot match. If there
is still alarm this problem, do as the way in chapter:
Abnormity of Gap Paper Print to detect.
E7.16
The scale cannot find the gap
intervals.
The paper type cannot match and change the type to plain
paper or reinstall gap label paper. If there is still alarm this
problem, do as the way in chapter:
Abnormity of Gap Paper Print to detect.
E7.17
The scale cannot find gap alignment
positions.
Label paper is used up or paper type cannot match with set
paper type. Please reinstall label paper.
E7.18
The printer is overheated and it needs
to cool down.
Please wait for a few seconds and try again.
E7.19
There is no response from the printer.
The printer may not be connected or in the state that the
printer could not print.
E7.30
Alarm for full storage of deals records.
Enter Account interface. Calculate reports and then clear the
reports.
8529-0637-2M Rev A DL Series Operation Manual
29
CARE AND MAINTENANCE
DO NOT submerge, pour or spray water directly on the scale base or weight display.
DO NOT expose the scale base or display to direct sunlight or temperature extremes.
DO NOT place the scale base or display in front of heating/cooling vents.
DO NOT use acetone, thinner or other volatile solvents for cleaning.
DO clean the scale base or display with a damp soft cloth and mild non-abrasive detergent.
DO remove power before cleaning with a damp cloth.
DO provide clean AC power and adequate protection against lightning damage.
DO keep the surroundings clear to provide clean and adequate air circulation.