EPS RS 232 Manual
Text of the manual
EPS Stromversorgung GmbH
Telefon +49 (0)821 570451-0
Electronic Power Supplies
Fax +49 (0)821 570451-25
Alter Postweg 101
[email protected]
D-86159 Augsburg
www.eps-germany.de
M a n u a l
EPS/MP
Table of Contents
Technical Specifications .............................................................................................................................................. 4
Ambient Conditions ............................................................................................................................................................ 4
Input Specifications ............................................................................................................................................................ 4
Output Specifications ......................................................................................................................................................... 4
AI Interface ......................................................................................................................................................................... 5
RS 232 ................................................................................................................................................................................. 5
RS 485 ................................................................................................................................................................................. 5
Technical Drawing ............................................................................................................................................................... 6
Important Safety Instructions ..................................................................................................................................... 7
Initial Operation .................................................................................................................................................................. 7
Unpacking ........................................................................................................................................................................... 7
Setting Up ........................................................................................................................................................................... 7
Visual Inspection ................................................................................................................................................................. 7
Mains Operation ................................................................................................................................................................. 7
Functional Description ................................................................................................................................................ 8
General Settings ......................................................................................................................................................... 9
Front Panel Description ...................................................................................................................................................... 9
Configuration ...................................................................................................................................................................... 9
Contrast ............................................................................................................................................................................ 10
Voltage Settings........................................................................................................................................................ 10
Ulimit and Ilimit ..................................................................................................................................................................... 10
OVP (Over Voltage Protection) ......................................................................................................................................... 10
AI-Type .............................................................................................................................................................................. 10
Remember Last Setting ..................................................................................................................................................... 10
Interface parameter (Option) ........................................................................................................................................... 10
Front Panel Operation .............................................................................................................................................. 11
Display and Settings .......................................................................................................................................................... 11
Current measurement values (Display) ................................................................................................................... 11
Main display ............................................................................................................................................................ 11
Operating modes .............................................................................................................................................................. 12
Main display overview ............................................................................................................................................ 12
Operating Mode description ................................................................................................................................... 13
Universal interface (Option) ..................................................................................................................................... 14
Commands ........................................................................................................................................................................ 14
Format ..................................................................................................................................................................... 14
Instruction Set ......................................................................................................................................................... 15
Quick view of commands ........................................................................................................................................ 15
Detailed description of commands ......................................................................................................................... 16
Response String ....................................................................................................................................................... 24
Ext. Control: Computer ............................................................................................................................................. 25
GPIB .................................................................................................................................................................................. 25
Status Word............................................................................................................................................................. 26
ESR-Register - Event-Status-Register....................................................................................................................... 26
RS232 interface ................................................................................................................................................................. 26
Interface Reconfiguration ....................................................................................................................................... 28
RS485 Interface ................................................................................................................................................................. 28
Interface Reconfiguration ....................................................................................................................................... 29
Ext. Control: AI Interface (Option) .............................................................................................................................29
Pin Assignment AI Interface .............................................................................................................................................. 30
Analog Input ..................................................................................................................................................................... 30
Set Point U (USet) ..................................................................................................................................................... 30
Set Point I (ISet) ........................................................................................................................................................ 31
Set Point OVP (UOVP) ................................................................................................................................................ 31
Analog Output .................................................................................................................................................................. 31
Monitor Set Point U (Umon) ...................................................................................................................................... 31
Monitor Set Point I (Imon) ......................................................................................................................................... 31
Monitor Actual Value P (Pmon) ................................................................................................................................. 31
Analog Output OVP (UOVPmon) .................................................................................................................................. 32
Monitor Output Voltage (UIstmon) ............................................................................................................................ 32
Monitor Output Current (IIstmon) .............................................................................................................................. 32
Digital Input ...................................................................................................................................................................... 32
Activation (Ext. Control) .......................................................................................................................................... 32
Soft-Interlock........................................................................................................................................................... 32
Blocking (Standby) ................................................................................................................................................... 32
Digital Output ................................................................................................................................................................... 32
Blocking (Standby) ................................................................................................................................................... 32
Const. Voltage mode (CV) ................................................................................................................................................. 33
Error .................................................................................................................................................................................. 33
Ext. Control: Ethernet (LAN) ......................................................................................................................................33
Manual Assignment of an IP under Microsoft Windows® ................................................................................................ 33
Monitoring the device via browser................................................................................................................................... 34
Controlling the device via Telnet ...................................................................................................................................... 34
Controlling the device via browser ................................................................................................................................... 35
Ext. Control: USB .......................................................................................................................................................35
Interface Reconfiguration ................................................................................................................................................. 35
Data Log Function (Option) ........................................................................................................................................36
Format of the saved Data ................................................................................................................................................. 36
Script Mode ...............................................................................................................................................................36
Executing/Loading a Script ............................................................................................................................................... 36
Commands ........................................................................................................................................................................ 37
Syntax ...................................................................................................................................................................... 37
Quick view of commands ........................................................................................................................................ 37
Detailed description of commands ......................................................................................................................... 37
Controller ..................................................................................................................................................................41
Controller Structure PVsim Mode and User Mode ........................................................................................................... 42
Controller Structure UIP Mode ......................................................................................................................................... 42
Controller Structure UIR Mode ......................................................................................................................................... 42
Controller parameters ...................................................................................................................................................... 43
Sense Mode ...............................................................................................................................................................44
Load connection without Sensor Conductor .................................................................................................................... 44
Load Connection with Sensor conductor .......................................................................................................................... 44
Load Distribution without Sensor Conductor ................................................................................................................... 44
Appendix ...................................................................................................................................................................45
Equivalent leakage current measurement according to VDE 0701 .................................................................................. 45
Notes .........................................................................................................................................................................47
0 - 50 °C
Storage temperature
-20 - 70 °C
Humidity
< 80 %
Operating altitude
< 2000 m
Vibration
10 - 55 Hz/1 min/2G XYZ
Shock
< 20 G
Weight
5 kW 19 kg, 10 kW 26 kg, 15 kW 33 kg
INPUT SPECIFICATIONS
EPS/MP models
(by max output power)
1.2 kW
2.4 kW
Connection
3 wire (1P+N+E)
AC socket on rear panel
IEC-C14
IEC-C20
Input voltage
230 Vac, 50/60 Hz (207-253 Vac 47-63 Hz)
Input current 1,2
≈ 6.5 A
≈ 13 A
Inrush transient current2
≈ 25 A
≈ 25 A
Main input fuse rating
10 A
16 A
Main input fuse type and location
built-in fast acting PCB mounted cartridge fuse
Recommended supply breaker value
& curve
16 A type D
16 A type D
Leakage current
≈ 1.5 mA
≈ 1.5 mA
THD input current
≈ 3.75 %
≈ 10.75 %
THD input voltage
≈ 1.87 %
≈ 2.55 %
Power factor
≈ 0.99
≈ 0.99
Efficiency type 1
≈ 88 % (with PFC)
≈ 89 % (with PFC)
Dissipated power 1
≈ 165 W
≈ 350 W
OUTPUT SPECIFICATIONS
Static voltage regulation
± 0.05 % + 2 mV
Static current regulation
± 0.1 % + 2 mA
Dynamic regulation
< 1-3 ms (typ.)
Ripple
< 0.2 % RMS (typ.)
Stability
± 0.05 %
Programming accuracy (Vout)
± 0.05 % +2 mV
Programming accuracy (Iout)
± 0.05 % +2 mA
Display accuracy (Vout)
< ± 0.5%
Display accuracy (Iout)
< ± 0.5%
Isolation
3,000 V
Over voltage protection
0 - 120 % Vmax
Circuit protection
OC/OV/OT/OP
Line regulation
< ± 0.1 % + 2 mV
1 for nominal output voltage and nominal output current
2 for nominal input voltage
(CV, Standby, Error)
Output type: Open collector with pull-up resistor 10 k after + 5 V
Isinkmax: 50 mA
Digital inputs
(Ext. Control, Standby)
Input resistance: 47 kΩ
Maximum input voltage: 50 V
High level: Ue > 2 V
Low level: Ue < 0.8 V
Analog outputs (Xmon)
Output resistance: 100 Ω
Minimum permissible load resistance: 2 kΩ
Minimum load resistance for 0.1 % accuracy: 100 kΩ
Analog inputs (Xset)
Input resistance: 1 MΩ
Maximum permissible input voltage: 25 V
Reference voltage
Reference voltage Uref: 10 V ± 10 mV
Output resistance: < 10 Ω
Maximum output current: 10 mA (not short-circuit-proof)
5 V - Supply voltage
Output voltage: 5 V ± 300 mV
Maximum output current: 50 mA (not short-circuit-proof)
RS 232
Signal inputs (RxD, CTS)
Maximum input voltage: ± 25 V
Input resistance: 5 kΩ (Type)
Switching thresholds: UH < - 3 V, UL > + 3 V
Signal outputs (TxD,RTS)
Output voltage (at RLast > 3 kΩ): min ± 5 V, Type ± 9 V, max ± 10 V
Output resistance: < 300 Ω
Short circuit current: Type ± 10 mA
RS 485
Maximum input voltage
± 5 V
Input resistance
> 12 kΩ
Output current
± 60 mA Max
High level
Ud > 0.2 V
Low level
Ud < - 0.2 V
Important Safety Instructions
IMPORTANT SAFETY INSTRUCTIONS
Please read this manual thoroughly before putting the device
into operation. Pay regard to the following safety instructions
and keep this manual nearby for future purpose.
This operating manual is based on the state of technology at the time of printing. However, it is possible that despite
regular control and correction, the present document contains printing errors or deficiencies. EPS Stromversorgung
GmbH assumes no liability for any technical, printing or translational errors within this manual.
INITIAL OPERATION
UNPACKING
Please make sure that the shipping carton and the packaging is free of damage. If external damage is found, it is
important to record the type of damage. Please keep the original packaging to ensure the device is adequately
protected in case it needs to be transported in the future or claims for compensation need to be asserted.
SETTING UP
To avoid electric shocks and product failure, the device should be installed in a temperature and humidity controlled
indoor environment. The ambient temperature must not exceed 50 °C. The device must never be exposed to liquids or
extreme humidity.
VISUAL INSPECTION
The unit must be examined immediately for defects or damages in transit. Damages caused during transport may be
loose or broken control knobs and bent or broken connectors. Do not use the device if any physical damage is
apparent. Please inform the carriers and a representative of EPS Stromversorgung immediately.
MAINS OPERATION
Make sure to verify the model number and voltage stated on the nameplate. Damages due to wrong power feed are
not covered by guarantee conditions.
The unit must only be operated when connected directly to the
mains. To avoid damage, do not connect the unit to
isolating transformers, auto-transformers, magnetic current
limiters or similar devices.
The following block diagram gives information about the various adjustment options.
Basically, four different operation modes are available:
UI mode
Unit is operated with current and voltage limitation.
UIP mode
Unit is operated with current, voltage and power limitation.
UIR mode
Unit is operated with current, voltage and power limitation. Additionally, the set value for
voltage is calculated by means of the present output current to simulate an internal
resistance.
Table mode
Set values for current and voltage are saved in a table. Therefore, UI characteristics can be
easily adjusted.
There are three different ways to program the table:
PVsim mode
The UI characteristic of a solar generator is calculated with the Uo, Ik, Umpp and Impp
parameters and then written to the table.
Memory card
The table can be programmed using a script from a memory card.
A script is a simple text file (� Script Control).
Digital interface
The table can be programmed using the digital interface (� Universal Interface, WAVE
Command bzw. DAT Command).
The adjustment of set points and the selection of an operation mode are performed via console (� Front Panel
Operation), interface (� Universal Interface) or analog/digital IO (� Ext. Control: AI-Interface).
In order of priority, commands which have been sent by interface come first, by analog/digital-IO come second and by
keyboard come third. For example, if the interface specifies the set point, the corresponding values will be sent to the
output, irrespective of other settings.
Another easy way to automate functions is offered by script control (� Script Control). A list of commands is saved to
the script memory and enables the user to change the chronological sequence of certain settings. The script memory
can be programmed via memory card or digital interface.
Measurement values of the latest output data are permanently available at all interfaces. Therefore, the present
output voltage can be read from the display or via digital interface, while the control of the unit is carried out via
analog/digital IO.
GENERAL SETTINGS
FRONT PANEL DESCRIPTION
The picture above shows a schematic view on the front panel of the EPS/MP. There are 3 buttons to control the unit.
Basic functions of the control buttons:
Standby
release or lock the output, quit OVP
Display
short press: change displayed information, long press: change between main menu and setup menu
Select
press: change selected menu point, rotate: change selected value
CONFIGURATION
The configuration menu can be accessed by holding the button Display for at least 1 second. This opens a menu
where general settings of the unit can be changed. To browse through the different options, the button Select must
be pushed. To change a setting the button Select must be rotated.
Setup options:
Ulimit
0 V-Vmax; set maximum output voltage which is selectable at the front panel
Ilimit
0 V-Vmax; set maximum output current which is selectable at the front panel
OVP
0 V- 1.2 x Vmax; set over voltage protection activation value
AI-Mode
5 V/10 V; select the AI-control voltage range
Remember Last Setting
ON/OFF; activate or deactivate the settings memory after a power down the unit
The displayed temperature is the temperature of the heat sinks. Temperature 1 is the temperature of the PFC heat
sink and temperature 2 is the temperature of the power unit heat sink.
After the unit has been switched on, the display shows the EPS logo. The contrast of the display can be adjusted by
using the rotary pulse encoder Select. Afterwards, the contrast settings will be saved automatically.
VOLTAGE SETTINGS
ULIMIT AND ILIMIT
Ulimit limits the maximum output voltage. The output voltage is limited to the selected value, irrespective of the values
that have been set at the front panel or at one of the interfaces. The adjustment range is 0 V up to the maximum
rated voltage of the device.
Ilimit limits the maximum output current. The output current is limited to the selected value, irrespective of the values
that have been set at the front panel or at one of the interfaces. The adjustment range is 0 A up to the maximum
rated current of the device.
These settings can only be changed at the display and they apply to all interfaces.
OVP (OVER VOLTAGE PROTECTION)
The output is shut immediately if the output voltage exceeds the selected value. The display indicates this status with
the word ‚OVP‘. To reset this error, push the button Standby. The OVP value applies to the front panel operation.
There may apply different values for the AI-interface and the digital interface. The digital interface is initialized with
the value which has been adjusted on the front panel. The adjustment range is 0 V up to the maximum rated voltage
of the device + 20 %.
AI-TYPE
This feature adjusts the voltage levels of analog input signals and analog output signals. Selectable ranges are 0-5 V
and 0-10 V.
REMEMBER LAST SETTING
If this option is activated (‚On‘), selected parameters will be kept after a blackout. If this option is deactivated (‚Off’),
standard setting (0V/0A/UI-Mode) will be loaded after supply voltage is enabled.
INTERFACE PARAMETER (OPTION)
The display shows all available digital interfaces and their changeable parameters. To see interface parameters, push
the button Display for 1 second. Push this button again to see the first interface and its changeable parameters,
which can be selected by pushing the rotary pulse encoder and changed by turning the rotary pulse encoder (function
of the parameters � Universal Interface).
Front Panel Operation
FRONT PANEL OPERATION
DISPLAY AND SETTINGS
Current measurement values (Display)
In normal mode, pushing the button Display switches between five different overview screens.
Main display
The main display shows current measure and set values. The display is divided in two separate displays. After enabling
the unit, the measured values for output voltage and putput current (position 1 and 2) are displayed. On the right
display (position 6) the actual set value (Preset Vset) is shown. To change this value, the rotary pulse encoder Display
must be turned. Pushing the button Select, toggles through the next set parameters (in UI mode it will be output
current). To open the mode select menu (left display, position 3) where different operation modes are available, the
button Select must be pushed again.
Selectable parameters according to operation mode:
U
Output voltage
I
Ouput current
P
Output power (UIP mode only � UIP mode)
Ri
Internal resistance (UIR mode only � UIR mode)
Umpp
MPP voltage (PVsim mode only � PVsim mode)
Impp
MPP current (PVsim mode only � PVsim mode)
Selectable options in current control mode (left display, position 5):
Loc
Front panel operation
Scr
Memory card operation
AI
Analog interface operation
Rem
Interface operation
LLO
Interface operation , Front panel operation locked
Dis
Unit locked via interlock input (option)
Available modes for operating status of the unit (left display, position 4):
STB
Standby mode
CV
Voltage limitation mode
C
Current limitation mode
CP
Power limitation mode
OVP
Deactivation of the unit by over voltage protection
Available operation modes of the unit (left display, position 3):
UI
Voltage and current limitation
UIP
Voltage, current and power limitation
UIR
Voltage and current limitation, simulated internal resistance
PVsim
Simulation of a photovoltaic characteristic
User
Simulation of a user-defined characteristic
Front Panel Operation
12
OPERATING MODES
Main display overview
Main display 1
After power up, the display shows the actual output voltage and output current.
Main display 2
After pushing the button Select once, actual output voltage and output power are shown on the display.
Main display 3
After pushing the button Select twice, actual output power and output current are shown on the display.
Main display 4
After pushing the button Select thrice, actual output voltage and output current are shown on the left display and
actual output power (P = U * I) and load resistor (R = V ÷ C) are shown on the right display. The values for power and
resistor will be calculated from the actual values of the output voltage and the output current.
Main display 5/diagram screen
After pushing the button Select four times, actual output voltage and output current are shown on the left display.
The output characteristic of the power supply is shown on the right display. The X-axis shows the output voltage and
the Y-axis shows the output current.
The picture above shows the UIR mode of the power supply. The dot marks the actual operation point of the unit. The
diagram is always scaled for the maximum allowed output current (this value can be set in the setup menu (Ilimit)) and
the maximum allowed output voltage (this value can be set in the setup menu (Ulimit)).
Front Panel Operation
Operating Mode description
UI Mode
In UI mode, the set values for voltage and current are transferred directly to the switch mode regulator. There is no
additional digital control.
UIP Mode
In UIP mode, the set values for voltage and current are transferred directly to the switch mode regulator. If the output
current exceeds the previously adjusted limit value, the current set point will be regulated.
UIR Mode
In UIR mode, the voltage set point is regulated in a way that a power supply unit with (adjustable) internal resistance
is simulated. The set value for current limiting is transferred directly to the switch mode regulator.
PVsim Mode
In PVsim mode, the diagram of a PV generator is simulated. Given values are open-circuit voltage Uo, short-circuit
current Ik, as well as the amounts of voltage and current by which the PV generator delivers the maximum power
(Umpp, Impp). Parameters can be found in the specification sheet of the simulated PV generator.
Values for Umpp may be in a range from 0.6 to 0.95 * U.
Values for Impp may be in a range from 0.6 to 0.95 * I.
Script Mode
In script mode, the unit is controlled by memory card. The display status ‚Mode‘ shows the present operating mode
‚UI‘. The lower right corner of the display shows the word ‚Scr‘, which indicates that script operation was selected. If
there is no memory card in the slot, this option cannot be selected. For detailed information about memory card
control and about how to build up a script, see � Script Control.
Universal interface (Option)
14
UNIVERSAL INTERFACE (OPTION)
All interfaces of the digital interface are equal. There is no shift between the interfaces. For example, the first
command can be issued via the IEEE interface while the second command can be issued via the RS232 interface. The
return values will be sent from that interface the command was issued from.
COMMANDS
Communication is based on an ASCII protocol. The following chapters describe how to write a command and give an
overview over the commands.
Format
A command consists of the command word, a parameter (if necessary) and a terminator. The character for the
terminator is Carriage Return or Line Feed .
Character
ASCII
Dec value
Hex value
Carriage Return
13
0d
Line Fee
10
0a
If the command contains a or character, it will not be processed. Therefore, a command can be cancelled
while entering. Though, a terminator ( or ) is necessary.
Character
ASCII
Dec value
Hex value
Escape
27
1b
Delete
127
7f
Commands are not case sensitive and may be mixed up. Therefore, the effect of the following commands is the same:
GTL, Gtl, gTL. Decimal places are optional and separated by a full stop ‘.‘ . The number of decimal places is not limited.
Therefore, the effect of the following commands is the same: UA,10, UA,10.0, UA,10.000000000, UA,0010,
UA,010.0000
The number of decimal places to be analyzed depends on parameter and unit type. It corresponds to the number of
decimal places, a command without a parameter would return. As a rule, decimal places are analyzed until a
resolution of 0.1% is reached.
Example: Evaluation of decimal places
EPS/MP with 600 V, 25 A
600 V * 0.1 % = 0.6 V � one decimal place
25 A * 0.1 % = 0.025 A � three decimal places
Optional, after a numerical value, a letter may be added to indicate the unit. However, this letter will not be analyzed.
Example: Attached letter as unit
UA,10.0 V � Resets output voltage to 10 V
UA,10.0 m � Caution! The ‚m‘ will not be evaluated, output voltage here is also 10 V
Example: A valid command with corresponding hex values
U
A
,
1
0
.
2
55 h
41 h
2 ch
31 h
30 h
2 eh
32 h
0 dh
Example: Adjustment of output voltage 10 V/5 A (full command sequence)
OVP,100 � adjusts OVP to 100 V
UA,10
� adjusts output voltage to 10 V
IA,5
� current limiting 5 A
SB,R
� output enabled
Universal interface (Option)
Instruction Set
The IEEE-488.2 standard demands several basic commands. Some commands may occur twice for compatibility
reasons (once in the EPS version and once in the (old) IEEE-488.2 version). The following syntax is used to describe the
commands:
[]
Square brackets
� optional parameter
<>
Angle bracket
� numerical value
{}
Curly bracket
� selection list
|
Vertical line
� separator within selection list
Example
GTR[,{0|1|2}] means that the command GTR can be used with or without parameters. If a parameter exists, it has to be 1, 2 or 3. Valid
commands are: GTR
GTR,1
GTR,2
GTR,3
IA[,] means that the command IA can be used either with or without parameters. If a parameter exists, it has to be a numerical
value.
Quick view of commands
Command
Description
Result
CLS* or CLS
Clear Status
Deletes the status byte
DAT,,
DIP
Data for user-defined characteristic
DCL
Device Clear
Initialization data reset
GTL
Go To Local
Activates front panel operation
GTR[,{0|1|2}]
Go To Remote
Activates digital interface operation
IA[,]
Set Imax
Adjusts current limiting
ID or *IDN?
Identification
Displays identification string
IMPP[,]
Set Impp
Adjusts MPP current during PVsim mode.
LLO
Local Lockout
Deactivates LOCAL button
LIMI
Limit Ia
Reads maximum adjustable current limitation
LIMP
Limit Pa
Reads maximum unit output.
LIMR
Limit R
Reads adjustable range for Ri within UIR mode.
LIMRMAX
Limit Rmax
Reads maximum adjustable range for Ri within UIR mode.
LIMRMIN
Limit Rmin
Reads minimum adjustable range for Ri within UIR mode.
LIMU
Limit Ua
Reads maximum adjustable voltage limitation
MODE[,{UI|UIP|UIR|PVSIM|
USER|Skript}]
Set Mode
Selects operation mode
MU[,]
Measure Ua
Measures present output voltage
MI[,]
Measure Ia
Measures present output current
*OPT?
Optional Identification Query
Displays units current hardware/software version
OVP[,]
Overvoltage Protection
Adjusts over voltage protection
PA[,]
Set Pmax
Adjusts power limitation
PCx[,,,
,,
,,
]
Program
Communication
Adjusts the interfaces
RA[,]
Set Ri
Adjusts internal resistance
REGLER[,,,,
]
Controller Parameters
Adjusts controller parameters for UIP, UIR and PVsim mode
RI or *RST
Reset Instrument
Resets hardware (no return value)
SB[,{S|R|1|0}]
Standby
Enables/blocks the output
SCR[,[,]]
Load Script
Programming of script memory
SS or *PDU
Save Setup
Saves previously made channel and interface parameter adjustments (no return
value)
STATUS
Status
Query of the units status (return values in binary format) (also see following
table)
STB or *STB?
Interface Status
UA[,]
Set Ua
Adjusts output voltage (if there are no parameters, present set point is
displayed)
UMPP[,]
Set Umpp
Adjusts MPP voltage in PVsim mode (if there are no parameters, present set point
is displayed)
WAVE
End Userwave Data
Ends transfer of user-defined output characteristic (gradual interpolation of
intermediate values)
WAVELIN
End Userwave Data
Ends transfer of user-defined output characteristic (linear interpolation of
intermediate values)
WAVERESET,,
Start Userwave Data
Starts transfer of user-defined output characteristic
Universal interface (Option)
16
Detailed description of commands
CLS* or CLS - Clear Status
This command deletes the status byte. It affects only the status byte of the interface, the command was sent from. No
return value. For detailed description of the status byte see the different interface chapters.
DAT,, - Data
Data for a user-defined characteristic. No return value. For detailed description of this command see � Wavereset.
DCL - Device Clear
This command resets the initialization data. No return value.
Caution: Interface parameters are also reset!
GTL - Go To Local
This command activates front panel operation. If ‚Local Lockout‘ (LLO) was activated before, it will also be reset. No
return value.
GTR[,{0|1|2}] - Go To Remote
This command activates digital interface operation. The optional parameter affects the future behavior of the unit
after switch on. Setting is saved permanently. No return value.
Optional parameter 0 = Deactivates automatic remote operation
The command GTR must be entered to activate the unit’s remote operation mode. This mode is useful if the unit shall be operated
manually and at the same time, measurement values shall be read out via the digital interface.
Optional parameter 1 = Activates remote operation on first addressing
Unit switches to remote operation when receiving a command via digital interface. The only exception is the GTL command, which
switches the unit to local mode.
Optional parameter 2 = Activates remote operation immediately after switch on
After the unit was switched on, remote mode is immediately activated. Front panel operation is deactivated.
IA[,] - Set Imax
This command adjusts current limiting. Entering the command without parameters displays the set value. If the set
value is higher than the maximum current of the unit, the range-error-bit within the ESR register of the interface is set.
The present set value remains unchanged. If the set value is higher than the Ilimit value, which was adjusted by the
user’s settings, but lower than the maximum current of the unit, the current is limited to the Ilimit value. No error
message.
Example: 300 A unit, Ilimit adjusted to 200 A via configuration menu
GTR
Remote operation
OVP,200
Over voltage protection 200 V
UA,10
Output voltage 10 V
IA,100
Output current 100 A
SB,R
Output open
IA,400
Output current 400 A, this command is ignored, because the current is higher than the maximum current of the device.
„Rangeerror“ is set within the status byte.
IA,250
Output current 250 A, since the output current was limited to 200 A via configuration menu, current limiting is set to 200
A. Error bit is not set.
IA
Query of the adjusted current.
IA,200.0A
Unit answers: Ilimit = 200 A
In master/slave mode, the current of a programmed device is adjusted. Connected in parallel, the total current is n x IA.
Example:
In M/S mode, 3 devices are connected parallel. IA,10 programs an output current of 10 A. All connected devices are set to 10 A. Since 3
devices have been connected parallel, the total current is 3 x 10A = 30A.
ID or IDN? - Identification
This command displays the identification string. Return value: .
Universal interface (Option)
IMPP[,] - Set Impp
This command adjusts the MPP current for PVsim mode. Entering the command without parameters displays the set
value. If the set value is higher than the maximum current of the unit, the range-error-bit within the ESR register of
the interface is set. The present set value remains unchanged. If the set value is higher than the Ilimit value, which was
adjusted by the user’s settings, but lower than the maximum current of the unit, the current is limited to the Ilimit
value. No error message follows.
Example:
GTR
Remote operation
OVP,200
Over voltage protection
UA,50.5
Open circuit voltage of a 50.5 V simulated PV generator
IA,10
Short circuit current of a simulated 10 A PV generator
UMPP,40.4
MPP voltage of a simulated 40.4 V PV generator
IMPP,8.2
MPP current of a simulated 8.2 A PV generator
MODE,PVSIM
Activates PV simulation mode
SB,R
Output open
In master/slave mode, the current of a programmed device is adjusted. In parallel connection the total current is n x IA.
LIMI - Limit Ia
With this command the user can read the maximum adjustable current limiting.
Example: 300A unit, Ilimit was adjusted to 200 A via configuration menu
LIMI
Query of maximum adjustable current
LIMI,200.0A
Unit answers: Ilimit = 200 A
LIMP - Limit Pa
With this command the user can read the unit’s maximum output.
Example: 10 kW unit
LIMP
Query of units output
LIMP,10000
Unit answers: 10 kW
LIMR - Limit R
With this command the user can read the adjustable range for Ri within UIR mode.
Example:
LIMR
Query of adjustable internal resistance
LIMR,0.015R,1.00R
Unit answers: 15 mOhm up to 1 Ohm
LIMRMAX - Limit Rmax
With this command the user can read the maximum adjustable range for Ri within UIR mode.
Example:
LIMRMAX
Query of maximum adjustable internal resistance
LIMRMAX,1.000R
Unit answers: 1 Ohm
LIMRMIN - Limit Rmin
With this command the user can read the minimum adjustable range for Ri within UIR mode.
Example:
LIMRMIN
Query of minimum adjustable internal resistance
LIMRMIN,0.015R
Unit answers: 15 mOhm
Universal interface (Option)
18
LIMU - Limit Ua
Reads maximum adjustable voltage limitation. This command requests the previously defined maximum output
voltage.
Example: 300 V unit was adjusted to 200 V via configuration menu
LIMU
Query of maximum adjustable current
LIMU,200.0V
Unit answers: Ulimit = 200 V
LLO - Local Lockout
This command deactivates the Local button. Unit cannot be switched to local mode by holding the button Standby.
No return value.
MI[,] - Measure Ia
This command measures the present output current.
Example:
GTR
Remote operation
OVP,200
Over voltage protection 200 V
UA,10
Output voltage 10 V
IA,1
Output current 1 A
SB,R
Output open
MI
Measures present output current
MI,0.567A
Unit answers: 567 mA
In master/slave mode with parallel connection the total current of all connected devices is displayed. Using the
parameter will show the value of each connected device. Numbering starts with 0.
Example:
MI,2 displays the measured output current at the bus of device number 3.
MODE[,{UI|UIP|UIR|PVSIM|USER|Skript|0|1|2|3|4|5}] - Set Mode
This command selects the operation mode. Entering the command without parameter displays the presently selected
operation mode. Entering the command with parameter activates the operation mode. Alternatively, the operation
mode can be indicated as number.
The following table shows the different settings:
Command
Function
MODE,UI
MODE,0
UI mode is activated
MODE,UIP
MODE,1
UIP mode is activated
MODE,UIR
MODE,2
UIR mode is activated
MODE,PVSIM
MODE,3
PVsim mode is activated
MODE,USER
MODE,4
User-defined UI characteristic is activated. The characteristic is defined with the
commands DAT, WAVE, WAVELIN and WAVERESET.
MODE,SKRIPT
MODE,5
Script mode is activated. The script is read from the memory card or loaded after
the command SCR has been entered.
Universal interface (Option)
MU[,] - Measure Ua
This command shows the measurement value of the present output voltage.
Example:
GTR
Remote operation mode
OVP,200
Over voltage protection 200 V
UA,10
Output voltage 10 V
IA,1
Output current 1 A
SB,R
Output open
MU
Measures present output voltage
MU,10.0V
Unit answers: 10 V
In master/slave mode with serial connection the total current of all connected devices is displayed. Using the
parameter will show the value of each connected device. Numbering starts with 0.
Example:
MU,1 displays the measured output voltage at the bus of device number 2.
*OPT? - Optional Identification Query
This command does an optional identification query, which means it displays the software version.
Example:
*OPT?
Query of version number
08.06.2012 V42
Unit answers: Version 42 vom 08.06.2012
OVP[,] - Over Voltage Protection
This command adjusts the over voltage protection. Entering the command without parameter displays the present set
point. If the set point is higher than a maximum of 1.2 x voltage of the unit, the range error bit within the ESR register
of the interface is set. The present set point remains unchanged.
Example:
GTR
Remote operation mode
OVP,200
Over voltage protection 200 V
UA,100
Output voltage 100 V
IA,10
Output current 10 A
SB,R
Output open
PA[,] - Set Plimit
This command adjusts the power limitation for UIP mode. Entering the command without parameter displays the
present set point. If the set point is higher than the maximum power of the unit, the range error bit within the ESR
register of the interface is set. The present set point remains unchanged.
Example:
GTR
Remote operation mode
MODE,UIP
UIP mode activated
OVP,200
Over voltage protection 200 V
UA,100
Output voltage 100 V
IA,10
Output current 10 A
PA,500
Power limitation 500 W
SB,R
Output open
In master/slave mode the power of a programmed device is adjusted. Total output is n x PA.
Example:
2 devices are in M/S mode. The command PA,100 sets the power output to 100 W. Both connected device are adjusted to 100 W. The
total output is 2 x 100 W = 200 W.
Universal interface (Option)
20
PCx[,,,,,,,] - Program Communication
This command adjusts the interfaces. The EPS/MP has a maximum of 3 digital interfaces (x = 1, 2 or 3). The
corresponding commands are PC1, PC2 or PC3. Type and number of parameters depend on the type of interface.
Currently there are no settings available for GPIB and LAN. Entering the command without parameter displays present
interface parameters.
Parameter
Function
Baud rate in bps
Data parity
O = Odd = Uneven parity
E = Even = Even parity
N = None = No parity bit
Number of data bits
Number of stop bits
Handshake
H = Hardware
S = Software
N = None (no handshake)
Character echo
E = Echo = echo on
N = None = echo off
Timeout in ms when switching between sending and receiving (RS485 only)
Allowed parameters for RS232 interface:
PCx,,,,,,
Parameter
Function
Baud:
1200, 2400, 4800, 9600, 14400, 19200, 38400, 57600, 62500, 115200
Parity:
O, E, N
Data bits:
7, 8
Stop bits
1, 2
Handshake:
H, S, N
Echo:
E, N
Allowed parameters for USB interface:
PCx,,,,,,
Parameter
Function
Baud:
1200, 2400, 4800, 9600, 14400, 19200, 38400, 57600, 62500, 115200
Parity:
O, E, N
Data bits:
7, 8
Stop bits
1, 2
Handshake:
H, S, N
Echo:
E, N
Note: The USB interface of the PC is controlled like a virtual COM port and therefore the parameters correspond to those of the RS232
interface.
Allowed parameters for RS485 interface:
PCx,,,,,
Parameter
Function
Baud:
1200, 2400, 4800, 9600, 14400, 19200, 38400, 57600, 62500, 115200
Parity:
O, E, N
Data bits:
7, 8
Stop bits
1, 2
Timeout:
0…100
If the interface parameters must be changed permanently, the data has to be saved after the PCx command with the
command . No return value.
Universal interface (Option)
Example:
PC1
Query of first interface parameters
PC1,RS232,9600,N,8,2,N,E
Unit answers: PC1 is a RS232 interface, 9600 bauds, 8 data bits, 2 stop bits, no handshake, no
parity, echo on.
PC1,115200,N,8,2,N,E
Adjust baud rate to 115200 baud.
The new baud rate is active immediately after the command has been sent!
PC2
Query of second interface parameters
PC2,RS485,9600,N,8,1,1
Unit answers: PC2 is a RS485 interface, 9600 bauds, 8 data bits, 1 stop bit.
Timeout when switching between receiving and sending is 1 ms.
PC2,9600,N,8,1,50
Increase timeout to 50ms.
PC3
Query of third interface parameters
PC3, EMPTY
Unit answers: Interface 3 is not available in this unit.
SS
Save settings.
RA[,] - Set Ri
This command adjusts the internal resistance for UIR mode. Entering the command without parameters displays the
present set point. If the set point is out of adjustment range the range error bit of the interface is set in the ESR
register. The present set point remains unchanged. Adjustment range can be requested with the commands
LIMRMAX and LIMRMIN.
Example:
GTR
Remote operation mode
MODE,UIR
UIR mode activated
OVP,200
Over voltage protection 200 V
UA,100
Output voltage 100 V
IA,10
Output current 10 A
RA,0.1
Internal resistance 0,1 Ohm
SB,R
Output open
REGLER[,,,,] – Controller Parameter
Settings for controller parameters in UIP, UIR and PVsim mode. Entering the command without parameters displays the
present settings as a table. The number of the parameter determines the parameter set which is to be adjusted.
0
Controller for UIP
1
Controller for UIR
2
Controller for PVsim
The range of values for controller parameters is 0 - 30000. New settings can permanently be saved with the command
SS. For a detailed description of the controller parameters see �Controller.
Example:
REGLER
Read present settings
Type P I D
P 10 20 5
Ri 20 20 2
Pv 10 5 5
Unit answers:
UIP Mode Kp = 20 Ki = 10 Kd = 5
UIR Mode Kp = 20 Ki = 20 Kd = 5
PV Mode Kp = 10 Ki = 5 Kd = 5
REGLER,0,10,10,5
New controller parameters for UIP mode
REGLER,1,22,18,5
New controller parameters for UIR mode
SS
Save new settings
RI or *RST - Reset Instrument
The unit executes a hardware reset. No return value.
Universal interface (Option)
22
SB[,{S|R|1|0}] - Standby
This command enables/disables the output. Entering the command without parameters displays the present standby
status. The commands SB,S and SB,1 switch the unit to standby mode, the output is disabled. The commands SB,R
and SB,0 disable the standby mode, the output is enabled.
Example:
GTR
Remote operation mode
OVP,200
Over voltage protection 200 V
UA,100
Output voltage 100 V
IA,10
Output current 10 A
SB,R
Output is active
SB
Retrieve standby status
SB,R
Unit answers: output is active
SCR[,[,]] - Load Script
With this command the script memory can be programmed. The command SCR without parameters initializes the
programming procedure. The command SCR with parameters writes the commands into the script memory. The
order of the commands corresponds to the order of commands of the script. Script commands and their parameters
are described in the chapter � Script Control.
Example:
GTR
Remote operation mode
OVP,200
Over voltage protection 200 V
SCR
Initialisation of script programming
SCR,U,12
1. script command: U = 12 V
SCR,I,15
2. script command: I = 15 A
SCR,UI
3. script command: mode UI
SCR,RUN
4. script command: activate output
SCR,LOOPCNT,10
5. start address loop
SCR,U,12
6. script command: U = 12 V
SCR,DELAY,8
7. script command: wait 8 ms
SCR,U,1
8. script command: U = 1 V
SCR,DELAY,1000
9. script command: wait 1 s
MODE,SKRIPT
Activate script mode
SB,R
Start script
SS or *PDU - Save Setup
Saves present unit parameters (interface parameter and controller parameter). No return value.
STATUS - Status
Query of device status. Return value in binary units. Function of the bits within the status byte:
Bit
Function
D15
Number of units in M/S mode. If no other device is
connected, 1 is displayed, if two devices are connected to
the bus, 2 is displayed etc. If M/S mode was disabled via
configuration menu, 0 is displayed.
D14
D13
D12
D11
- reserved -
D10
- reserved -
D9
- reserved -
D8
Limit mode, unit in power limitation mode
D7
Limit mode, unit in current limitation mode
D6
Local lockout (1 = LLO active, 0 = LLO not active)
D5
Local (1 = front panel operation)
D4
Remote (1 = digital interface operation)
D3
- reserved -
D2
- reserved -
D1
Standby (1 = unit in standby mode)
D0
OVP (1 = shut down by over voltage protection)
Universal interface (Option)
Example:
STATUS
Status query
STATUS,0000000100010000
Unit answers: Remote operation mode, power limitation
UA[,] - Set Umax
This command adjusts the voltage limitation. Entering the command without parameters displays the present set
point. If the set point exceeds the maximum voltage of the unit, the range error bit within the ESR register of the
interface is set. The present set point remains unchanged. If the set point is higher than the selected value for Ulimit,
but lower than the unit’s maximum voltage, voltage limitation is restricted to Ulimit. There is no error message.
Example:
GTR
Remote control operation
OVP,320
Over voltage protection 320 V
UA,100
Output voltage 100 V
IA,10
Output current 10 A
SB,R
Output is active
UA,400
Output voltage 400 V. This command is ignored because the voltage is higher than the maximum voltage of the unit.
Range error is set within the status byte.
UA,250
Output voltage 250 V. Since the output voltage was limited to 200 V via configuration menu, voltage limitation is adjusted
to 200 V. An error bit is not set.
UA
Query of adjusted voltage
UA,200.0V
Unit answers: set point Ua = 200 V
In master/slave mode the voltage of the programmed device is set. In master/slave serial connection the total voltage
is n x UA.
Example:
3 devices are connected in series while in M/S mode. With UA,10 an output voltage of 10V is programmed. Therefore all connected
devices are adjusted to 10V. Since three devices are connected in series, the total voltage is 3 x 10 V = 30 V.
UMPP[,] - Set Umpp
This command adjusts the MPP voltage for PVsim mode. Entering the command without parameters displays the
present set point. If the set point is higher than the maximum voltage of the unit, the range error bit within the ESR
register of the interface is set. The present set point remains unchanged. If the set point is higher than the Ulimit value
which was adjusted in the configuration menu, but lower than the maximum voltage of the unit, the voltage limitation
is restricted to Ulimit. There is no error message.
Example:
GTR
Remote operation mode
OVP,200
Over voltage protection 200 V
UA,50.5
Open circuit voltage of a simulated PV generator 50.5 V
IA,10
Short-circuit current of a simulated PV generator 10 A
UMPP,40.4
MPP voltage of a simulated PV generator 40.4 V
IMPP,8.2
MPP current of a simulated PV generator 8.2 A
MODE,PVSIM
Activate PVsim mode
SB,R
Output active
In master/slave mode the MPP voltage of the programmed device is adjusted. When connected in series, the MPP
total voltage is n x UMPP.
WAVE - End Userwave Data
This command ends the transfer of a user defined output characteristic. Interpolation of interim values is layered. For
detailed information about the function of this command see � Wavereset.
WAVELIN - End Userwave Data
This command ends the transfer of a user defined output characteristic. Interpolation of interim values is linear. For
detailed information about the function of this command see � Wavereset.
Universal interface (Option)
24
WAVERESET, - Start Userwave Data
Starts the transfer of a user defined output characteristic. The parameters Umax and Imax define the maximum voltage
of the output characteristic. Afterwards, the fulcrums of the UI characteristic can be entered using the command
DAT. The characteristic ends with the commands WAVE or WAVELIN.
Example:
GTR
Remote operation mode
OVP,200
Over voltage protection 200 V
WAVERESET,100,10
Output characteristic with a maximum of 100 V and 10 A
DAT,90,1
Fulcrum 90 V, 1 A
DAT,50,5
Fulcrum 50 V, 5 A
DAT,10,9
Fulcrum 10 V, 9 A
WAVELIN
End of characteristic, linear interpolation
MODE,USER
Activates the created UI characteristic
SB,R
Output active
For more information and examples of user defined characteristics see � Wave, Wavelin and Programming of
characteristics (Script Operation).
Response String
The response string has the following format:
command comma value unit
The value is a floating point string with a ‘.‘ as delimiter.
Command
Response
Command
Response
IA
IA,12.34A
MU
MU,10.0V
LIMU
LIMU,500.0V
PA
PA,12W
LIMI
LIMI,30.00A
RA
RA,0.015R
LIMP
LIMP,15000W
UA
UA,100.0V
LIMRMIN
LIMRMIN,0.015R
UMPP
UMPP,90.2V
LIMRMAX
LIMRMAX,0.110R
IMPP
IMPP,10.01A
LIMR
LIMR,0.015R,0.110R
OVP
OVP,600.0V
Example: Command as ASCII and HEX protocol
L
I
M
U
,
5
0
0
.
0
V
4C
49
4D
55
2C
35
30
30
2E
30
56
0D
0A
The digits after the decimal point correspond to the resolution of the unit.
Example
UA at a 600 V unit UA,123.4V
UA at a 50 V unit
UA,23.44V
The digits before the decimal point depend on the present measurement value.
Example: 600 V unit
UA,10.4V
UA,220.3V
UA,1.1V
Example: 50 V unit
UA,1.23V
UA,10.47V
UA,0.01V
Ext. Control: Computer
EXT. CONTROL: COMPUTER
GPIB
Connection is carried out with a 24pin Centronics connector. The device address is adjusted with the DIP switches S1-
S5. Here, S1 has the lowest priority and S5 the highest.
No
Name
Function
1
DIO1
Data line 1
2
DIO2
Data line 2
3
DIO3
Data line 3
4
DIO4
Data line 4
5
EOI
End or Identify
6
DAV
Data Valid
7
NRFD
Not Ready For Data
8
NDAC
No Data Accepted
9
IFC
Interface Clear
10
SRQ
Service Request
11
ATN
Attention
12
SHIELD
Shield
13
DIO5
Data line 5
14
DIO6
Data line 6
15
DIO7
Data line 7
16
REN
Remote Enable
18 - 23
GND
Ground
24
SGND
Signal Ground
Table: Device address
S1
S2
S3
S4
S5
Address
S1
S2
S3
S4
S5
Address
Off
Off
Off
Off
Off
0
Off
Off
Off
Off
On
16
On
Off
Off
Off
Off
1
On
Off
Off
Off
On
17
Off
On
Off
Off
Off
2
Off
On
Off
Off
On
18
On
On
Off
Off
Off
3
On
On
Off
Off
On
19
Off
Off
On
Off
Off
4
Off
Off
On
Off
On
20
On
Off
On
Off
Off
5
On
Off
On
Off
On
21
Off
On
On
Off
Off
6
Off
On
On
Off
On
22
On
On
On
Off
Off
7
On
On
On
Off
On
23
Off
Off
Off
On
Off
8
Off
Off
Off
On
On
24
On
Off
Off
On
Off
9
On
Off
Off
On
On
25
Off
On
Off
On
Off
10
Off
On
Off
On
On
26
On
On
Off
On
Off
11
On
On
Off
On
On
27
Off
Off
On
On
Off
12
Off
Off
On
On
On
28
On
Off
On
On
Off
13
On
Off
On
On
On
29
Off
On
On
On
Off
14
Off
On
On
On
On
30
On
On
On
On
Off
15
On
On
On
On
On
31
The device address is read in only when the unit is switched on. Changing the DIP switches while the unit is active will
not change the device address!
Table: Device equipment (according to IEEE-488.1)
Ext. Control: Computer
26
SH1
Source Handshake function available
AH1
Acceptor Handshake function available
T6
Talker, Serial Poll, end addressing by MLA
L4
Listener function, end addressing by MTA
SR1
Service request available
RL1
Remote/Local function available
PP0
No parallel poll function
DC1
Device clear function available
DT0
No trigger function
C0
no controller function
E1
Open-collector driver
Status Word
The status word can be read with the command or <*STB?>. Return value: STB,xxxxxxxx
Table: Reading the status word
Bit
Function
D7
n/a
D6
SRQ is set, if SRQ was requested
D5
ESB is set, if a byte was set within the SES register
D4
MAV is set, if a message is available
D3
n/a
D2
see table
D1
see table
D0
see table
Table: Error messages
D3
D2
D1
D0
Error
0
0
0
1
Syntax
0
0
1
0
Command
0
0
1
1
Range
0
1
0
0
Unit
0
1
0
1
Hardware
0
1
1
0
Read
ESR-Register - Event-Status-Register
The ESR register can be read using the command <*ESR?>. Return value: ESR,xxxxxxxx. After the query, the ESR
register is deleted.
Bit
Function
D7
Power on
D6
Command error
D5
User request
D4
Execution error
D3
Device dependent error
D2
Query error
D1
Request control
D0
Operation complete
RS232 INTERFACE
The connection of the RS232 interface is carried out with a 9pin sub D connector.
Ext. Control: Computer
No
Name
Function
1
N.C.
2
TxD
Data line from unit to PC
3
RxD
Data line from PC to unit
4
N.C.
5
GND
GND
6
N.C.
7
CTS
Reception of the PC, signal direction from PC to unit
(only required for active Hardware handshake)
8
RTS
Reception of the unit, signal direction from unit to PC
(only required for active Hardware handshake)
9
N.C.
The interface can be operated using the following parameters:
Baud rate:
1200, 2400, 4800, 9600, 14400, 19200, 38400, 57600, 62500, 115200
Parity:
O = Odd = uneven parity
E = Even = even parity
N = None = no parity bit
Number of data bits:
7 or 8
Number of stop bits:
1 or 2
Handshake:
H = Hardware
S = Software
N = None (no handshake)
The defined character for XON is 0 x 11 and for XOFF it is 0 x 13.
Interface parameters in delivery state are 9600 baud, no parity, 8 data bits, 1 stop bit, echo on. The status word can be
read with the command or <*STB?>. The following functions are assigned to the bits:
Bit
Function
D15
Parity error
D14
Over run error
D13
Framing error
D12
Timeout error
D11
Echo on
D10
used internally, can be 1 or 0
D9
Hardware handshake (RTS/CTS)
D8
Software handshake (XON/XOFF)
D7
Parity enable
D6
Parity mode (1 = odd, 0 = even)
D5
Stop bit (1 = 2 stop bits; 0 = 1 stop bit)
D4
Data format (1 = 8 bit; 0 = 7 bit)
D3
used internally, can be 1 or 0
D2
� Table
D1
� Table
D0
� Table
Table: Error messages
D2
D1
D0
Error
0
0
1
Syntax
Ext. Control: Computer
28
0
1
0
Command
0
1
1
Range
1
0
0
Unit
1
0
1
Hardware
1
1
0
Read
If echo is on, the interface confirms each incoming character by sending the same character back to the sender. The
interface parameters can be adjusted via software and the command . These settings can be saved with the
command .
Interface Reconfiguration
In case, the user has forgotten the active setup, there are two ways of reconfiguring the interface:
• sending the command from one of the other interfaces
• using the display to configure the interface � Interface Parameters
RS485 INTERFACE
The interface works with the following parameters:
Baud rate:
1200, 2400, 4800, 9600, 14400, 19200, 38400, 57600, 62500, 115200
Parity:
O = Odd = uneven parity
E = Even = even parity
N = None = no parity bit
Number of data bits:
7 or 8
Number of stop bits:
1 or 2
Timeout:
0-100 ms
A timeout is the time between receipt and sending of a message. The connected device is selected by entering the
command and placing the number of the device and ‘#’ before it. When using the word ‚ALL‘ instead of a number, the
following command will be executed by all connected devices (e. g. #1,ID; #22,GTR, #ALL,GTL).
Example:
#1,ID
#22,GTR
#ALL,GTL
The status word can be read with the command or <*STB?>. The following functions are assigned to the bits:
Bit
Function
D15
Parity error
D14
Over run error
D13
Framing error
D12
Timeout error
D11
n/a
D10
n/a
D9
n/a
D8
n/a
D7
Parity enable
D6
Parity mode (1 = odd, 0 = even)
D5
Stop bit (1 = 2 Stop bits; 0 = 1 Stop bit)
D4
Data format (1 = 8 bit; 0 = 7 bit)
D3
n/a
D2
� Table
D1
� Table
D0
� Table
Table: Error messages
D2
D1
D0
Error
0
0
1
Syntax
Ext. Control: AI Interface (Option)
0
1
0
Command
0
1
1
Range
1
0
0
Unit
1
0
1
Hardware
1
1
0
Read
Interface parameters are configured via software using the command . The settings can be saved with the
command .
Interface Reconfiguration
In case, the user has forgotten the active setup, there are two ways of reconfiguring the interface:
• sending the command from one of the other interfaces
• using the display to configure the interface � Interface Parameters
EXT. CONTROL: AI INTERFACE (OPTION)
The device can be controlled via control signals and by using the analog/digital In/Out.
Ext. Control: AI Interface (Option)
30
PIN ASSIGNMENT AI INTERFACE
No (BD25)
Dir
Name
Function
1
analog out
Umon
Monitor set point U
2
analog out
Imon
Monitor set point I
3
analog out
Pmon
Monitor actual value P
4
analog out
OVPmon
Monitor actual value OVP
5
digital in
Soft-Interlock
Interlock function (Caution: Interlock does not correspond to the machinery directives)
6
-nc-
-
-
7
digital out
CV
Signals „Const. Voltage“ mode
8
analog out
Uistmon
Monitor output voltage
9
gnd
GND
-
10
digital out
Standby
Signals standby
11
gnd
GND
-
12
-nc-
-
-
13
REF10
10 V-Vref
Output 10 V reference voltage
14
analog in
Uset
Set point U
15
analog in
Iset
Set point I
16
analog in
In 2
-
17
analog in
OVPset
Set point OVP
18
analog in
In 4
-
19
digital in
Ext. Control
Activates analog control
20
digital in
Standby
Activates standby
21
analog out
Iistmon
Monitor output current
22
pwr
+ 5 V
Output 5 V supply voltage
23
gnd
GND
-
24
digital out
Error
Signals shut down by OVP
25
gnd
GND
-
26
-nc-
-
-
All digital outputs are OC outputs with a pull-up resistance after + 5 V. All analog inputs and outputs can be operated
in 0-5 V or in 0-10 V mode.
ANALOG INPUT
Set points are adjusted as dc voltage (0-5 V or 0-10 V) on the analog inputs. The voltage range can be chosen in the
configuration menu.
Set Point U (USet)
Set point output voltage. The set point refers to the rated voltage of the unit.
Ext. Control: AI Interface (Option)
Example:
EPS/MP at 600 V output voltage, AI is adjusted to 10 V, desired output voltage = 100 V.
Uset = 10 V * 100 V ÷ 600 V = 1,667 V
Set Point I (ISet)
Set point output current. The set point refers to the rated voltage of the unit.
Example:
EPS/MP at 100 A output voltage, AI is adjusted to 10 V, desired output current = 2 A.
Iset = 10 V * 2 A ÷ 100 A = 0.200 V
Set Point OVP (UOVP)
The output is deactivated immediately if the output voltage exceeds the adjusted value. This error is indicated on the
display with the word „Error“. To rest this error, standby mode must be activated. Adjustment range is 0 V up to the
maximum rated voltage of the device + 20%.
Example:
EPS/MP with 600 V output voltage, AI is adjusted to 10 V, desired OVP voltage = 650 V.
Adjustment range: 600 V + 20% = 720 V
Uset = 10 V * 650 V ÷ 720 V = 9.028 V
ANALOG OUTPUT
On the analog outputs, present measurement values are displayed as dc voltage values (regardless of the actual
operation mode). Therefore the AI interface can be used for monitor purposes. Maximum voltage is 5 V / 10 V.
Monitor Set Point U (Umon)
Present set point of the output voltage. Measurement value refers to the rated voltage of the device.
Example:
EPS/MP at 600 V output voltage, AI is adjusted to 10 V, voltage at output Umon = 2 V.
Present set point: Uset = 2 V * 600 V ÷ 10 V = 120 V
Monitor Set Point I (Imon)
Present set point of the output current. Measurement value refers to the rated current of the device.
Example:
EPS/MP at 100 A output current, AI adjusted to 10 V, voltage at output Imon = 2 V.
Present set point: Iset = 2 V * 100 V ÷ 10 V = 20 A
Monitor Actual Value P (Pmon)
Present set point for output power. It is calculated by the controller from measurement values of output voltage and
output current. Measure value refers to the rated power of the device.
Example:
EPS/MP at 15 kW rated power, AI adjusted to 10 V, voltage at output Pmon = 5 V.
Present output power Pout = 5 V * 15 kW ÷ 10 V = 7.5 kW
Ext. Control: AI Interface (Option)
32
Analog Output OVP (UOVPmon)
Present set point for over voltage protection. Measurement value refers to the rated voltage of the device + 20%.
Example:
EPS/MP at 600 V output voltage, AI adjusted to 10 V, voltage at output Umon = 2 V. Signal refers to 600 V + 20% = 720 V.
Present set point: Uovp = 2 V * 720 V ÷ 10 V = 144 V
Monitor Output Voltage (UIstmon)
Present measure value point value for output voltage. Measurement value refers to the rated voltage of the device.
Example:
EPS/MP at 600 V output voltage, AI adjusted to 10 V, voltage at output Uistmon = 6 V.
Present output voltage Uout = 6 V * 600 V ÷ 10 V = 360 V
Monitor Output Current (IIstmon)
Present measure value for output current. Measurement value refers to the rated current of the device.
Example:
EPS/MP at 100 A output current, AI adjusted to 10 V, voltage at output Iistmon = 4 V.
Present output current Iout = 4 V * 100 A ÷ 10 V = 40 A
DIGITAL INPUT
The digital inputs can be used to adjust the operation mode for the analog control. Inputs are low active.
Activation (Ext. Control)
The input ‚Ext. Control‘ can be used to chose the operation mode ‚AI‘. The AI interface is activated by an applied
voltage of + 5 V up to + 10 V. Front panel operation is deactivated. Operation mode is marked as ‚AI‘ on the display.
The digital interface takes priority over the AI interface. The settings from AI interface have no effect if the device is
toggled to ‚Remote‘.
Soft-Interlock
The Interlock deactivates the unit immediately, when the connection between interlock input (Pin 5) and
+5 V voltage is opened. In this case, the output of the unit cannot be activated, neither by interface nor by front panel.
The difference between Soft-Interlock and Interlock is that a Soft-Interlock does not correspond to the machinery
directives. If the Soft-Interlock is triggered, the unit switches into Interlock-Mode.
Blocking (Standby)
The standby mode is activated by an applied voltage of + 5 V up to + 10 V.
The output signal is enabled, if the input ‚Standby‘ is toggled inactive.
DIGITAL OUTPUT
On the digital outputs, actual device adjustments are displayed (irrespective of the actual operation mode). Therefore
the AI interface may be used for monitoring functions also. Gauges are consistent with a negative logic: S = Set = log.
0; R = Reset = log. 1
A set output has a voltage level of < 0.6 V. A reset output has a voltage level of > 1.2 V.
Blocking (Standby)
The blocking of the output is set, if the unit is in standby mode.
Ext. Control: Ethernet (LAN)
CONST. VOLTAGE MODE (CV)
Constant voltage mode is set, when the unit is in constant voltage mode.
ERROR
An error is set, if the unit has been shut down by OVP. To reset this error, the standby mode must be activated.
EXT. CONTROL: ETHERNET (LAN)
To communicate with the EPS/MP via network, it is necessary to assign an IP address to the device first. In delivery
status, the device automatically draws an IP from the network. In its practical operation, this behavior is unfavorable,
because after each activation the device has a new IP address. Therefore, to each device an individual, permanent IP
address should be assigned.
The status word can be read with the command or <*STB?>. Only bits from D0 up to D2 are in use. All other
bits can be 1 or 0.
Table: Error messages
D2
D1
D0
Error
0
0
1
Syntax
0
1
0
Command
0
1
1
Range
1
0
0
Unit
1
0
1
Hardware
1
1
0
Read
MANUAL ASSIGNMENT OF AN IP UNDER MICROSOFT WINDOWS®
After the console has been opened, clicking on ‚Start‘ and ‚Ausführen‘ opens an input field. After this, the command
cmd or command opens a DOS window. The following has to be entered: arp -s xxx.xxx.xxx.xxx yy-yy-yy-yy-yy-yy.
‚xxx‘ is the desired IP address, ‚yy‘ is the MAC address of the unit, which can be read from the unit’s back panel.
The entry of the IP has been added to the ARP table. The device has no new IP yet. Execute telnet with new IP on port
1: telnet xxx.xxx.xxx.xxx 1. ‚xxx‘ is the desired new IP address. Connection fails but the new IP address is thus assigned
to the device. The assignment of the IP is still dynamical, which means that these settings get lost after the device has
been cut off from the network. The user interface can be loaded by entering the new IP address:
http://xxx.xxx.xxx.xxx. By selecting the menu item ‚Config‘, the IP address can be adjusted. Java must be supported by
your browser to adjust the IP.
Ext. Control: Ethernet (LAN)
34
MONITORING THE DEVICE VIA BROWSER
The user interface opens via direct request of the IP address: http://xxx.xxx.xxx.xxx. The item menu ‚Control‘ opens
the control of the unit. Java must be supported by your browser to control the device.
When controlling the device via browser, another control via
telnet must not be active!
CONTROLLING THE DEVICE VIA TELNET
The device can be controlled directly via port 10001. After the console has been opened, a click on ‚Start‘ and
‚Ausführen‘ opens an input field. After the commands cmd or command have been entered, a DOS window opens
with: telnet xxx.xxx.xxx.xxx 10001.
Alternatively, many terminal programs offer the possibility to establish a TCP/IP or telnet connection.
When controlling the device via port 10001, the user interface
of the device must not be open in a browser!
Ext. Control: USB
CONTROLLING THE DEVICE VIA BROWSER
The user interface can be opened via IP address: http://xxx.xxx.xxx.xxx. The menu ‚Display‘ opens the monitoring of
the unit. Java must be supported by your browser to control the device. Displayed are all present measurement
values, which are updated every 2 seconds. When using the monitoring function, automatic toggle to remote
operation when receiving a command should be deactivated (command ).
EXT. CONTROL: USB
The USB interface provides a virtual COM port for the PC. Via this port, the unit can be controlled as with a normal
RS232 interface, e. g. with a terminal program. Corresponding drivers for all current operating systems are available as
download: http://www.ftdichip.com/Drivers/VCP.htm.
The status word can be read with the command or <*STB?>.
Bit
Function
D15
Parity error
D14
Over run error
D13
Framing error
D12
Timeout error
D11
Echo on
D10
used internally, can be 1 or 0
D9
Hardware handshake (RTS/CTS)
D8
Software handshake (XON/XOFF)
D7
Parity enable
D6
Parity mode (1 = odd, 0 = even)
D5
Stop bit (1 = 2 Stop bits; 0 = 1 Stop bit)
D4
Data format (1 = 8 bit; 0 = 7 bit)
D3
used internally, can be 1 or 0
D2
� Table
D1
� Table
D0
� Table
Table: Error messages
D2
D1
D0
Error
0
0
1
Syntax
0
1
0
Command
0
1
1
Range
1
0
0
Unit
1
0
1
Hardware
1
1
0
Read
The defined character for XON is 0 x 11 and for XOFF it is 0 x 13.
Interface parameters are adjusted by software with the command and afterwards they can be saved with the
command .
INTERFACE RECONFIGURATION
In case, the user has forgotten the active setup, there are two ways of reconfiguring the interface:
Data Log Function (Option)
36
• sending the command from one of the other interfaces
• using the display to configure the interface � Interface Parameters
DATA LOG FUNCTION (OPTION)
The device has a data log function. A memory card may be used as data logger. All measurement values will be saved,
separated by tabulators, in a text file. The time interval may be adjusted from 1-4294967 s (= 71 minutes). To activate
the data log function, a memory card must be inserted. The root directory of the memory card must contain a text file
named “EPSLOG.txt“. The new data will be written into this file.
The memory card must be inserted or removed in standby
mode only!
In case, that the first entry of the first line of the file is "interval=xxxx" (xxxx = time in seconds), the memory interval is
adjusted accordingly. The entry must be written in lower case letters and without space characters. If the interval
remains unspecified, the memory interval is 60 seconds.
Example:
interval=30
The data log function is active whenever the device is not operating in standby mode. The function is indicated by a
small memory card symbol in the upper right corner of the main display. Whenever a new data set is written, the
symbol will be displayed as filled for ca. 1 second. In case the memory card is full, the symbol will be crossed out.
FORMAT OF THE SAVED DATA
The first entry shows the present operation mode. The second entry shows the present operation mode followed by
‚Udc‘ and ‚Idc‘.
Example:
USER
I-Limit 1,0
10,02
USER
OVP 0,0
0,00
UI
U-Limit 100,01
0,10
UIP
U-Limit 100,0
0,10
SCRIPT MODE
Operation sequences may be programmed in a script which can be read in from a memory card. A script is a text file,
which includes a sequence of commands. Alternatively, the script memory can be programmed via digital interface
using the command SCR. For more information about the use of this command see � Commands. The device is able
to process up to 250 commands.
EXECUTING/LOADING A SCRIPT
The script must be saved on a MMC or SD card as text file with .txt or .scr ending.
The mode ‚Scr‘ must be selected from the main display. Pushing the rotary pulse encoder will open the file selection
menu. The script file can be selected. An error message appears if, the file could not be read correctly or, if the read in
setup is invalid (e. g. IA 40 at a 10 A unit). To return to the file selection menu, the rotary pulse encoder or the button
Display must be pushed again. The script has been loaded and can be started by pushing the button Standby.
The last five commands of the script are displayed in the field ‚Preset’. The actual command is placed on top. The
script ends when button Standby is pushed and device is toggled to standby mode.
COMMANDS
Syntax
Upper and lower case are nonrelevant. Therefore, the following commands deliver the same results: PMAX 100 Pmax
100 pMaX 100. Delimiters must be placed between two commands or between command and parameter. Valid
delimiters are: blank, tabulator, LineFeed , Carriage Return and equal sign (=).
Numerical values must be placed as basic units and may not be followed by characters. Valid delimiters for decimal
places are: point and comma. No characters must be attached: U 12,345 U 10.00 U 12. The command UAC 12.114V is
invalid, because it is followed by a character.
All commands may be written consecutively, but must be separated by blanks: U 10 I 1 UIP LOOP RUN. Due to its
unclear syntax, this style is not recommendable.
Quick view of commands
Command
Description
Result
; or #
comment
Entering commented text.
DELAY, DELAYS
delay
Delays execution of the script for duration of time t.
I
output current
Set point output current.
IMPP
MPP current
MPP current in ampère for PV simulation.
LOOP, LOOPCNT
Loop
Define return address.
PMAX
maximum output UIP mode
Maximum output for UIP mode.
PV
PVsim mode
Activate PVsim mode.
RI
internal resistance UIR mode
Set point internal resistance in ohm for UIR mode.
RUN
open output
Enable output.
STANDBY
close output
Disable output.
U
set point output voltage
Set point output voltage in V.
UI
UI mode
Activate UI mode.
UIP
UIP mode
Activate UIP mode.
UIR
UIR mode
Activate UIR mode.
UMPP
set point MPP voltage
Set point MPP voltage (for PV simulation)
USER
set points current and voltage
Generates set points for current and voltage using the internal table.
WAIT
wait
Waits for user action.
WAVE, WAVELIN
characteristic programming
Characteristic programming.
Detailed description of commands
; or # - Comment
Comment on text. All characters from ; or # up to end of line will be ignored. This function is not available when
programming via digital interface.
Example:
# This is a comment
UIP # This command activates the UIP mode
; Comments can also start with a semicolon
DELAY, DELAYS - Time delay
The commands DELAY and DELAYS delay the execution of the script. The following number defines the duration of
the delay in ms (milliseconds). Maximum duration of delay is 65535 ms.
Example:
# UI mode
U 10
# Output voltage 10 V
I 1
# Output current 1 A
RUN
# Activate output
DELAY 200
# Wait 200 ms
U 100
# Adjust output voltage to 100 V
DELAYS 10
# Wait 10 seconds
STANDBY
# Deactivate output
I - Set point output current
This command adjusts the set point for the output current in ampere.
Example:
I 9.8
# Output current 9.8 A
IMPP - Set point MPP current
This command adjusts the set point for the MPP current for PV simulation in ampere.
Example:
IMPP 8.123
# MPP current 8.123 A
LOOP, LOOPCNT - Return Loop
Usually the script ends with the last command. A return address can be defined with the command . From
this point on, the processing will continue after the last command of the script. To interrupt the program, button
Standby must be pushed. The command equals the command . But here, the command
defines the number of loops. The maximum number is 65535.
Example:
# This example activates the output for 10s, then deactivates it for 2s
# and starts from the beginning. This will continue until the user interrupts the
# process by pushing the button Standby.
UI
# UI mode
U 100
# Output voltage 100 V
I 10
# Output current 10 A
LOOP
# Start address
RUN
# Activate output
DELAYS 10
# Wait 10s
STANDBY
# Deactivate output
DELAYS 10
# Wait 2s
# This example works like the previous one.
# The cycle is executed only 10 times, and then the script ends.
# UI mode
U 100
# Output voltage 100 V
I 10
# Output current 10 A
LOOPCNT 10
# Start address
RUN
# Activate output
DELAYS 10
# Wait 10s
STANDBY
# Deactivate output
DELAYS 10
# Wait 2s
PMAX - maximum output in UIP mode
Maximum output for the UIP mode.
PV - Pvsim mode
Activates the PVsim mode.
Example:
PVSIM
#Activate PV simulation
RI - Internal resistance UIR mode
This command adjusts the set point for the internal resistance in UIR mode.
RUN - Activate output
The command RUN resets the standby mode and activates the output.
Example:
RUN
# Activate output
STANDBY - Deactivate output
The command STANDBY deactivates the output and activates standby mode.
Example:
STANDBY
# Deactivate output
U - Set point output voltage
Set point for output voltage in V.
Example:
U 100
# Output voltage 100 V
UI - UI-Modus
This command activates the UI mode. Unit works current and voltage regulated.
Example:
UI
# UI mode
UIP - UIP mode
This command activates the UIP mode. Unit works current, voltage and power regulated.
UIR - UIR mode
This command activates the UIR mode. Unit works current and voltage regulated. Additionally, an internal resistance
is simulated.
UMPP - Set point UMPP voltage
Set point for MPP voltage for PV simulation in V.
Example:
UMPP 80.42
# MPP voltage 80.42 V
USER - Set points current and voltage
This command generates the set points for current and voltage by using the internal table. Thereby, different UI
characteristics can be created. The tables can be created beforehand by using the command WAVE.
WAIT - Waiting for user action
The program is stopped until the user pushes the button Standby.
Example:
; Starter characteristic:
UI
; UI mode
I 10
; Current limitation 10 A
U 12
; Output voltage 12 V (->100%)
RUN
; Activate output
LOOP
; Start address after end of the script
WAIT
; Waits until rotary pulse encoder is pushed
U 10,5
; 1. ramp
U 9
; Command is processed within 1 ms. Therefore the
U 7,5
; ramp has 5 interim values.
U 6
U 4,5
DELAY 15
; 15 ms pause
U 4,8
; 2. ramp
U 5,1
; Command is processed within 1 ms. Therefore
U 5,4
; the ramp has 5 interim values.
U 5,7
U 6
DELAY 2000
; 2000 ms pause
U 6,6
; 3. ramp
U 7,2
; Command is processed within 1 ms. Daher
U 7,8
; The ramp has 10 interim values.
U 8,4
U 9
U 9,6
U 10,2
U 10,8
U 11,4
U 12
WAVE, WAVELIN - Characteristic programming
The command WAVE is used to start the characteristic programming. The command is followed by numerical values,
which indicate the desired voltage and current. Finally, followed by the command with a prefixed '-' characteristic ( -
WAVE).
WAVE
...
-WAVE
The command WAVELIN equals the command WAVE.
WAVELIN
...
-WAVELIN
With the WAVELIN command, the interim values between the fulcrums are linear interpolated, with the WAVE
command they are layered (see example). Characteristics which are not constant or negative in their course are
accepted but the behavior of the unit may not be predicable.
Example:
; Characteristic with layered interim values
; This script delivers the blue characteristic in the diagram
WAVE
; Start of the table
100 10
; 100 V 10 A
50 25
; 50 V 25 A
10 100
; 10 V 100 A
-WAVE
; End of the table
RUN
; Output active
; Characteristic with linear interim values
; This script delivers the red characteristic
WAVE
; Start of the table
100 10
; 100 V 10 A
50 25
; 50 V 25 A
10 100
; 10 V 100 A
-WAVELIN
; End of the table
RUN
; Output active
If output voltage or output current is changed afterwards, the characteristic keeps its course. Though values are
stretched or compressed to the new range.
Example:
# This script generates a blue characteristic
# After a 10 second delay it switches to the green characteristic:
WAVE
# Start of the table
100 10
# 100 V 10 A
50 50
# 50 V 50 A
10 100
# 10 V 100 A
-WAVE
# End of the table
U 100
# Output Voltage 100 V
I 100
# Output Current 100 A
USER
# Select characteristic
RUN
# Output open
DELAY 10000
# Wait 10 seconds
U 50
# Output Voltage 50 V
I 50
# Output Current 50 A
CONTROLLER
The software contains three digital PID controllers. Each controller is assigned to the UIR, UIP and PVsim mode. When
required, the controller parameters can be changed via universal interface.
Improper adjustment of the controller can lead to controller
oscillations which may damage connected devices!
CONTROLLER STRUCTURE PVSIM MODE AND USER MODE
The current set point is calculated from the output voltage and a table. This set point stands for the input signal of the
PID controller after it was subtracted from the actual value. The PID controller releases the current set point for the
power supply. The current set point is limited to the short circuit current, as a maximum. The voltage set point of the
power supply is permanently set to the open circuit voltage of the table. In PVsim mode the current is regulated while
the voltage is fixed.
CONTROLLER STRUCTURE UIP MODE
The output voltage is multiplied with the output current. The result is subtracted from the power set point. This signal
is the input signal of the PID controller, which releases the current set point for the power supply. The current set
point is limited to the current set point, as a maximum. The voltage set point of the power supply is permanently set
to the voltage set point. In UIP mode the current is regulated, while the voltage is fixed.
CONTROLLER STRUCTURE UIR MODE
The measured output current is multiplied with the adjusted internal resistance. The result is subtracted from the
adjusted set point and is then the set point for the voltage controller:
Usoll = Uset - Ia * Ri
The output signal is limited to the voltage set point. The current set point of the power supply is permanently set to
Isoll. In UIR mode the voltage is regulated while the current is fixed.
CONTROLLER PARAMETERS
common differential equation of a PID controller:
E
Controller deviation
Kp
Proportional coefficient
Tn
Reset time
Tv
Derivative time
Since the digital controller is a discrete-time system, the integral is replaced by a summation and the differential by a
difference:
The following equation puts the controller into practice within the software:
Parameters P, I and D are calculated as follows:
Controller parameters can be programmed via digital interface using the command REGLER.
Ts
Sampling time
Ts
Sampling time = 300 us
( )
⋅
∫
dt
e t dt+Tv de
e+ Tn
y = Kp
1
y= 0,1�P�ei+0,001�I�∑
m=− ∞
m=i
em+0,1�D�(ei− ei−1)
P= 10�Kp I= 1000�Kp�Ts
Tn
D= 10�Kp�Tv
Ts
(
)
−
−
−∞
∑
i 1
i
=i
m
m=
m
i
e
Ts e
e + Tv
Tn
= Kp e + Ts
y
LOAD CONNECTION WITHOUT SENSOR CONDUCTOR
Almost all our power supplies are provided with sensor conductor connectors to compensate the voltage drop on the
load. In case, these connectors are not in use, they must be short-circuited with correct polarity to the load outputs
and directly to the output connectors. By no means, current may flow over the sense connectors. In case of multiple
loads, the user has to provide a central load distribution point. To reduce peak loads and for an HF impedance
terminator, a 1-10 µF capacitor should be connected to the output.
LOAD CONNECTION WITH SENSOR CONDUCTOR
The following points must be considered, when existing sense cables are connected directly to the load or to the
central load distribution point:
•
remove existing sense cable bridges from the power supply
•
directly connect + sense and - sense with correct polarity to the load distribution point
•
connect + sense and - sense conductors to a 1-47 µF capacitor
•
protect sense cable or at least twist + sense and - sense
•
select load line cross section, so that voltage drop is < 0.4 V
•
avoid overload of power supplies (voltage drop per line x current)
If thus you paid attention to the points stated above, oscillation occurs through load or power induction and complex
load situations, please contact our company EPS.
LOAD DISTRIBUTION WITHOUT SENSOR CONDUCTOR
To ensure a proper use, a central load distribution situation is essential. Illustration 2 shows a correct load
distribution. Illustration 1 shows an insufficient supply of load 2, load 3 etc. via parallel load conductors. In practice, it
may occur that an optimal distribution is not possible. Illustration 3 shows a mixed distribution, where at least the
largest consumers are supplied centrally.
EQUIVALENT LEAKAGE CURRENT MEASUREMENT ACCORDING TO VDE 0701
The equivalent leakage current measuring according to DIN VDE 0701-1 may deliver results beyond the norm.
Cause: Measurements are primarily performed on so-called EMC-filters at the AC input of the units. These filters are
built symmetrical, that means capacitors are installed between L1/2/3 and PE. While measuring, L1, L2 and L3 are
connected together and the current flow to PE is measured. Therefore up to 3 capacitors are connected parallel which
doubles or triples the measured leakage current. This is permissible according to the norm.
Quotation from the norm of 2008, appendix D:
„When measuring protection conductor currents with the equivalent leakage current measuring method, it is
important to note that devices with protective grounds and symmetrical circuits may have results, due to the wiring,
that are up to three or four times higher than the leakage current of one phase.“
Graphical representation of a balanced circuit:
Example illustration from the norm protective ground measuring - equivalent leakage current measuring method:
Note: The illustration shows the measurement method for two-phase power supplies. In the three-phase version, phase N is
replaced by L2 and/or L3.