© Excell Precision Limited 2016. All rights reserved Worldwide.

The information contained herein is the property of Excell Precision Limited and is supplied without liability for errors or omissions. No part may be reproduced or used except as authorised by contract or other written permission. The copyright and the foregoing restriction on reproduction and use extend to all media in which the information may be embodied.

EXCELL PRECISION CO., LTD.

TABLE OF CONTENT Function Table.................................................................................................................................... 2 Intructions for Use ............................................................................................................................. 5 Preparing to Use the Scale .............................................................................................................. 5 Chapter 1 Introduction ...................................................................................................................... 7 1-1 Features ................................................................................................................................... 7 1-2 Specifications .......................................................................................................................... 7 1-3 Appearance ............................................................................................................................. 7 1-4 Display Description ................................................................................................................ 9 1-5 Power Supply .......................................................................................................................... 9 1-6 Keypad Function ...................................................................................................................10 1-7 Error Messages .................................................................................................................... 11 1-8 Available Units....................................................................................................................... 11 1-9 Firmware Version.................................................................................................................. 11 Chapter 2 General Function Setting.............................................................................................12 2-1 Backlight and Auto. Power Off Setting ..............................................................................12 2-2 Simple Counting Mode ........................................................................................................12 2-3 Accumulation .........................................................................................................................13 2-4 Hold Mode (Animal) .............................................................................................................14 2-5 Self-Test Mode ......................................................................................................................15 Chapter 3 Further Function Setting ..............................................................................................16 3-1 Enter Function Setting .........................................................................................................16 3-2 Function Setting ....................................................................................................................16 3-2-1 Hi / Lo / OK Setting (P0 ChK) .....................................................................................17 3-2-2 RS-232 Setting (P2 CoM) ............................................................................................18 3-2-3 Transmit Mode Setting .................................................................................................19 3-2-4 Real Time Clock Setting ..............................................................................................20 3-2-5 Continuous Transmit Rate (rPS) ................................................................................20 3-3 Other Function Settings (P4 oth) .......................................................................................21 3-4 Weight Unit Setting (P5 unt) ...............................................................................................22 3-5 External calibration (P6 ZCL) .............................................................................................23 3-6 Restore Default Setting (P7 rSt).........................................................................................23 Chapter 4 Wireless Connection Instruction ..................................................................................24 Appendix 1 Output Format.............................................................................................................30 Appendix 2 ASC II Code Table ......................................................................................................32 Appendix 3 7-Segment Display Characters ................................................................................33 Appendix 4 Wiring Instructions......................................................................................................34

EXCELL PRECISION CO., LTD.

Function Table For non-approval models Main menu Sub-menu Available settings Description P0 ChK (Hi/OK/Lo Setting) (3-2-1) SEt h High limit value (weighing) SEt L Low limit value (weighing) PCS h High limit value (counting) PCS L Low limit value (counting) bEEP no No beep oK* Beep within the high and lower limits value nG Beep beyond the high or lower limits value P1 rEF Function Reserved Pr2 CoM (RS-232 Setting) (3-2-3) ModE (3-2-4) Auto Auto accumulate transmit CoMAnd Command mode Cont Continuous transmit St1* Stable transmit (Single) StC Stable transmit (Continuous) Pr1 Press key to transmit Pr2 Press key to transmit bAud Baud rate setting: 600, 1200, 2400, 4800, 9600*, 19200 Pr Communication setting: *n81, E71, o71 rPS Continuous Transmit rate: 1, 2, 4, 8, 16 or MAX* (3-2-6) PtyPE PtUP* Print type: Standard print Lab Output format: 0*, 1, 2, 3 Prt LAnG ENG* Language:English rtC RTC setting (3-2-5) rtCFO Time display: year_month_day or day_month_year rS485 RS-485 ID entering P3 CAL Function Reserved P4 oth (Other setting) (3-4) AnM Animal mode: on, oFF* AVErG Auto average unit weight: on, oFF* r tAr Tare range St Continuous tare: on*, oFF Ft FnC Foot switch: ZEro*, tArE, rint P5 unt (weight unit setting) (3-5) G Use gram: on, oFF Lb Use pound: on, oFF oZ Use pound ounce: on, oFF tJ Use Taiwan Tael: on, oFF hJ Use H.K. Tael: on, oFF ViSS Use viss: on, oFF P6 ZCL External calibration P7 rSt Restore default setting  Default settings are marked by *

EXCELL PRECISION CO., LTD.

For approval models Main menu Sub-menu Available settings Description P0 ChK (Hi/OK/Lo Setting) (3-2-1) SEt h High limit value (weighing) SEt L Low limit value (weighing) PCS h High limit value (counting) PCS L Low limit value (counting) bEEP no No beep oK* Beep within the high and lower limits value nG Beep beyond the high or lower limits value Pr2 CoM (RS-232 Setting) (3-2-3) ModE (3-2-4) Auto Auto accumulate transmit CoMAnd Command mode Cont Continuous transmit St1* Stable transmit (Single) StC Stable transmit (Continuous) Pr1 Press key to transmit Pr2 Press key to transmit bAud Baud rate setting: 600, 1200, 2400, 4800, 9600*, 19200 Pr Communication setting: *n81, E71, o71 rPS Continuous Transmit rate: 1, 2, 4, 8, 16 or MAX* (3-2-6) PtyPE PtUP* Print type: Standard print Lab Output format: 0*, 1, 2, 3 Prt LAnG ENG* Language:English rtC RTC setting (3-2-5) rtCFO Time display: year_month_day or day_month_year rS485 RS-485 ID entering P4 oth (Other setting) (3-4) AnM Animal mode: on, oFF* AVErG Auto average unit weight: on, oFF* r tAr Tare range St Continuous tare: on*, oFF Ft FnC Foot switch: ZEro*, tArE, rint P5 unt (weight unit setting) (3-5) G Use gram: on, oFF Lb Use pound: on, oFF oZ Use pound ounce: on, oFF tJ Use Taiwan Tael: on, oFF hJ Use H.K. Tael: on, oFF ViSS Use viss: on, oFF  Default settings are marked by *

EXCELL PRECISION CO., LTD.

SPECIAL NOTICE While installing the load cell, power cord hookup or replacing a new rechargeable battery, the indicator housing must be opened. It must be done by a technician assigned by your electronic indicator provider to avoid affecting the waterproof ability of this indicator. Before opening the housing, make sure the indicator is dry, if there is any liquid on it, please wipe it with a clean cloth. HOW TO INSTALL THE HOUSING After installing the load cell, power cord hookup or replacing a new rechargeable battery, the housing must be screwed by the assigned order as shown below. Screw lightly first, then screw them tight using a 12 kgf-cm torsion. P.s. Please use a torsion-adjustable screw driver. Screwing order: 1 3 6 5 2 4  QWS  GWS  GWS

EXCELL PRECISION CO., LTD.

Intructions for Use 1. The load placed on the weigh pan must NOT exceed the maximum weighing capacity of the scale. 2. Protect the scale from high temperatures. 3. Avoid objects impacting with the scale. Do not drop loads onto the scale or subject the weigh pan to any strong shock loads. 4. Please operate or charge the scale in an open area. Do not squeeze the power cord to avoid wire on fire. 5. Any suggestion for product is welcomed Preparing to Use the Scale 1. Locate the scale on a firm level surface free from vibrations for accurate weight readings. 2. Adjust the four levelling feet (if fitted) to set the scale pan level. 3. Avoid operating the scale in direct sunlight or drafts of any kind. 4. If possible avoid connecting the scale to ac power outlet sockets which are adjacent to other appliances to minimise the possibility of interference affecting the performance of the scale. 5. Remove any weight that might be on the weigh pan before the scale is switched on and avoid leaving weight on the pan for long periods of time 6. All goods weighed should be placed in the centre of the weigh pan for accurate weighing. The overall dimensions of the goods being weighed should not exceed the dimension of the weigh pan. 7. Once the scale has been powered on, it will go through an LCD display test and it is ready for use when the display shows zero. 8. The scale requires 15~20 minutes warm up before operation to ensure best accuracy 9. Please note when the symbol keeps flashing on the screen, the batteries need to be recharged. 10. Introduction of Storage Battery Thank you for purchasing EXCELL Weighing Indicator, to help use the product properly, operate smoothly, and extend its life cycle, please read this manual carefully.

EXCELL PRECISION CO., LTD.

No burning Caution Corrosion Due to the storage battery adopt the advanced free-maintaining technique, customers need not to replenish electrolyte. The scale should be recharged every 3 months to prevent failure of the internal rechargeable battery. 1. The battery should be charged for 8~10 hours. 2. The temperature of battery should below 45℃. Maintaining 1. Please do not discharge with over-current when using the battery. Please charge the battery after discharging current. 2. Please take down the battery when the scale is not used for a long time or break the connection of cathode. 3. Do not short the battery terminals to check whether there is current. Please check whether the connection point is firm to guarantee good connection. 4. The battery should be replaced by specialized person. No reverse-battery or the product will be damaged. a) Anode of battery should be connected with Anode of product battery(usually red cable) b) Cathode of battery should be connected with Cathode of product battery (usually brown cable or black cable) c) See the picture following Safety warnings 1. The electrolyte of battery is caustic which causes metal, cotton, etc to corrode. 2. The hydrogen will be resolved when using or charging the battery and it will cause explosion when approaches fire. Brown cable(or black cable) connected with Cathode of battery Red cable connected with Anode of battery Warning explosion Children faraway

EXCELL PRECISION CO., LTD.

80 mm Chapter 1 Introduction 1-1 Features  Extra-large and wide LCD display (175 x 70mm) 6 digits with 55mm height  COOL WHITE LED backlight  QWS with 304 stainless steel housing while GWS with plastic ABS housing.  Sealed to IP68, Waterproof, mist-proof and dustproof (Only use cables of 3mm~5mm diameter to ensure correct sealing of the cable glands)  Kilogram (kg) and pound (lb) weighing modes  Full range tare; Pre-tare; Auto zero tracking; Sampling counting;  Gross/Net indication  Hold function; Check mode Lo/Hi/OK; Auto average unit weight;  Adjustable gravity value  Low power indication and auto power off  AC/DC power in and rechargeable battery.  Built-in RS-232  Options: wireless transmitter, foot switch, pressure release valve, and RS-485 1-2 Specifications  Analogue Input: Input Sensitivity 0.3 V/d (Min.)  Input Signal Range: -1mV~+14mV  Input Zero Range: -1mV~+5mV  Load Cell Excitation: 5V DC  Load Cell Drive Capacity: Up to 8 x 350 load cells  Non-linearity: 0.01% of full scale  A/D Resolution: 500,000 counts (Maximum)  Operating temperature: -10℃ ~ 40℃ 1-3 Appearance QWS 232 mm 170mm

EXCELL PRECISION CO., LTD.

[Standard] [Option] GWS [Standard] [Option] Power RS-232 Load Cell Power Foot switch or RS-485 Pressure relieve valve or RS-485 RS-232 Load Cell 90mm 156m m 238mm Power Load Cell RS-232 Foot switch RS-485 Load Cell RS-232 Power

EXCELL PRECISION CO., LTD.

1-4 Display Description HI : Upper limit “” indications description OK : Value between HI and LO 1 : “STABLE” indication LO : Lower limit 2 : “GROSS” indication kg : Unit “kilogram” 3 : “Hold” indication g : Unit “gram” 4 : “Pre-tare” indication lb : Unit “pound” 5 : Range 2 斤 : Unit “hk tael” or “Taiwan tael” 6 : Range 1 Pcs : “Counting mode” indication 7 : “M+” indication O : “Zero” indication Net : “Net” indication : Flashing,Low Power indication 1-5 Power Supply Power Supply Selection ➀ 6V / 4.5Ah rechargeable battery ➁ 110/230VAC ±15% (plugged-in) Power Consumption Approximately DC 31 mA (Indicator + Load Cell) Approximately DC 65 mA (Indicator + Load Cell + Display backlight) Approximately DC 80 mA (Indicator + Load Cell + Wireless 100M) Approximately DC 65 mA (Indicator + Load Cell + Display backlight +Wireless 100M) Charging Voltage DC 10V/1A Low Battery Warning Please note when the ( ) symbol keeps flashing on the display, the battery should be recharged. 1 2 3 4 5 6 7

EXCELL PRECISION CO., LTD.

 The scale will turn off automatically after a few hours when the low battery warning symbol shows up. The scale must be fully charged, before operating again.  When the battery status indication is full, the power is about 6.1V; each block is about 0.2V; when the battery warning symbol shows up, the power is about 5.4V. 1-6 Keypad Function :Press the key to switch the indicator on or off. : Zero key. If the weighing value is within the range of zero balance, it can be re-zeroed.  Confirm key in function operating  Press this key for 3 seconds to enter backlight setting in weighing mode. : Shift between gross weight and net weight.  Press this key for 3 seconds to shift units in weighing mode.  Press this key for 3 seconds to exit in simple counting mode  Press this key to exit or return in function operating. : Print key. It needs to connect with printer. According to the setting, press this key to transmit simple or completed mode format.  Press this key to clear the entering numbers. : Accumulation key. According to the setting, press this key to transmit simple or completed mode format.  Press this key to move the cursor leftward when entering numbers.  Press this key for 3 seconds to display in high resolution mode. : Check accumulation counts and total weight.  Press this key for 3 seconds to enter simple counting mode in weighing mode.  Press this key to move the cursor rightward when entering numbers. : Tare key. It can be tare except when the weight is negative and the maximum capacity.  It is selection key in function operating.  Press this key to increase number when entering numbers. Pre-tare function: When there is nothing on the platter and weight is zero, press key and enter pre-tare weight. After enter pre-tare weight, press key to comfirm or press key to exit without saving. Pre-tare mode, keypad function as following ⇒ upward key ⇒ move cursor leftward ⇒ save setting ⇒ clear ⇒ move cursor rightward ⇒ exit without saving

EXCELL PRECISION CO., LTD.

Compound key + :Only when it is set“ON”in Hold function, press these 2 keys together to call up Hold function. + :Press these 2 keys together to call up Hi/Lo/Ok setting. + :Press these 2 keys together to clear the accumulation data when there is no weight in accumulation mode. M+ indication “”disappears. High Resolution:Press key for 3 seconds to shift to high resolution display. And it returns to original resolution after release key for 3 seconds. 1-7 Error Messages The EEPROM is not working correctly. (EEPROM is missing or circuit neaby EEPROM is damaged.)  Zero is higher than the zero range when switching the indicator on.  Zero is lower than the zero range when switching the indicator on.  ADIC value is over the maximum range.  The weight of the object is over 9 divisions of the maximum capacity.  The weight of the object is under -1/6 maximum capacity. 1-8 Available Units kg 1 g = 0.001 kg g 1 g = 1 g lb 1 g = 0.002204623 lb lb,oz 1 g = 0.03527396 oz Taiwan Tael 1 g = 0.02666667 Tael H.K. Tael 1 g = 0.02645546 Tael viss 1 kg = 0.612245 viss 1-9 Firmware Version When power is off, hold key and press key to wait till display shows 01 AdC and then press key twice to enter 03 VEr. Press key and displays firmware version 02027 and then press key to display maintenance number 011 for 2 secs. Press key to back to last screen and displays 03 VEr.

EXCELL PRECISION CO., LTD.

Chapter 2 General Function Setting 2-1 Backlight and Auto. Power Off Setting Press key for 3 seconds to enter backlight setting (SEtbL). Press key again to confirm. Press key to select on/oFF and press key to exit. Auto. Power off setting: Press key for 3 seconds to enter backlight setting (SEtbL), and then press key to select SEt oF. Press key again to confirm. Press key to select time 0, 3,5,15 or 30 min. After selecting time, press key to save the setting or press key to exit.  Default settings are marked by * 2-2 Simple Counting Mode In weighing mode, hold key to enter simple counting mode and display shows “PCS 10”. Use key to select sampling number 10, 20, 50,100 or 200. Select a sampling number, and put appropriate weight on platter, and press key. Display shows “-------”. The scale enter counting mode after weight is stable, and display shows the sampling number. (0, 3, 5, 15, 30) . kg Backlight on* Backlight off Auto. Power off or or or 0 1 . kg Press key for 3 secs (Press key to select 10, 20, 50,100 or 200 and pres key to confirm) Press key to save the setting or press key to exit and back to sampling mode or press key for 3 secs to back to weighing mode.

EXCELL PRECISION CO., LTD.

 Press key before finishing sampling, it will exit and back to weighing mode.  After Power-off, the scale automatically memorizes the sampling number, and it is available when “Pcs” unit is selected next time.  When the setting “automatic average unit weight “is turned on, if the object on platter > the previous sampling number more than 5 pcs, and also <200% the previous sampling number, the scale will execute unit weight calibration automatically. 2-3 Accumulation Manual Accumulation Please set as following: P2 CoM  ModE  Pr2. Manual accumulation will sum up the individual weighing values into the memory by pressing key. This can be repeated 99 times or up to the capacity of the system. To check accumulation counts and accumulation weight by pressing key. To print by pressing key. To clear the accumulation data when there is no weight by pressing + keys. Then M+ indication “”disappears. Auto. Accumulation Please set as following: P2 CoM  ModE  Auto. Auto. accumulation will sum up the individual weighing values into the memory automatically. This can be repeated 99 times or up to the capacity of the system. To check accumulation counts and accumulation weight by pressing key. To print by pressing key. To clear the accumulation data when there is no weight by pressing + keys. Then M+ indication “”disappears. After stable, ▽1 shows up Counting mode Total weight Unit weight Put sampling quantities 1 0 Pcs After 0.5 secs After 0.5 secs 1 0 Pcs 1 Pcs . kg 1 . kg 1 Press key to save the setting or press key to exit and back to sampling mode or press key for 3 secs to back to weighing mode.

EXCELL PRECISION CO., LTD.

Examples for Manual Accumulation Setting as following: P2 COM  Lab2/Prt 1 Setting as following: P2 COM  Lab0/Prt0 1 First weighing 1 First weighing 2 Second weighing 2 Second weighing 3 Third weighing 3 Third weighing 4 Number of weighings print 4 Number of weighings print  Please see Appendix 1 Output Format (A) 2-4 Hold Mode (Animal) When the animal mode is enabled (P4 oth  AnM is set to on), press + keys to enter Hold Mode. : Hold mode disabled : “Peak hold” mode: The scale keeps displaying the maximum weight when the weight is continually changing. Press any key to exit this mode. : “Stable hold 1” mode: When the weight is stable, the LCD shows the current weight value (Not changeable due to external variables). Press any key to exit this mode. : “Stable hold 2” mode: When the weight is stable, the LCD shows the current weight value (Not changeable due to external variables). When the weight backs to zero(<10e), the hold mode is cancelled automatically. : “Animal scale hold” mode: When the scale returns back to zero, the display shows “ - - - - - - ”. After the animal or object is on the platter and the scale becomes stable, the display shows the weight value and hold. Then when the animal or object is off the platter, the display shows “ - - - - - - ” (or the weight is less than 10e) and the hold function is off. If the scale is hardly stable when the animal is on the platter, the scale shows the average weight in 10 seconds and holds the status. Back to weighing mode Back to weighing mode Back to weighing mode Press key to save the setting or press key to exit with out saving and back to weighing mode. (Press key to select 0, 1, 2, 3 or 4 press key to confirm)

EXCELL PRECISION CO., LTD.

Internal Value Mode (must hook up full-bridge Load Cell to test)  Pres key and display shows internal value  Please check the internal value is within range  Check whether the backlight is on  Press key to back to last screen, the display shows Keypad Test Mode  Press key to enter, display shows  Keypad’s internal cod: = 04, =05, =07, =06, = 03  Press key to back to last screen, the display shows Firmware Version Display Mode  Press key to enter, display shows the firmware version  Press key again, the display shows maintenance number for 2 seconds  Press key to back to the last screen, display shows Back to the Last Screen Press key, exit self-test mode, the scale will reboot automatically. Hold Mode (Animal) Setting 2-5 Self-Test Mode When power is off, hold key and press key to wait till display shows 01 AdC to enter “Self-Test Mode” % Counts averaging setting Press key to select 1, 2, 4, 8, 16, 32, 64 Press key to confirm. Default setting = 8 Error range setting (1%~100%) Press key to adjust; Press key to confirm Press or key to move cursor Default setting = 10%

EXCELL PRECISION CO., LTD.

Chapter 3 Further Function Setting 3-1 Enter Function Setting Power on the scale and before the scale counts down to zero, press key first. And then press keys in order and within 10 seconds to enter Function setting. If you press the wrong key, please press key again and press three keys in order before entering weighing mode. 3-2 Function Setting  Switch the switch SWA1 back to the LOCK position for approval models, while switch the switch SWA1 to the ADJ position for non-approval models. Press key to select function. After selection, press key to enter the setting. Hi/Lo/OK setting Function Reserved RS-232 setting Other function setting Unit setting External Calibration Restore default setting Function Reserved Press key to exit and back to weighing mode.  Only for non-approval models are marked by

EXCELL PRECISION CO., LTD.

3-2-1 Hi / Lo / OK Setting (P0 ChK) After enter Hi/Lo/OK setting, the display shows “P0CHK” or press + keys in weighing mode to enter the setting (SEt h). The cursor starts at the third digits. After entering numbers, press key to save the setting or press key to exit without saving.If make mistakes, e.g. Hi value﹤Lo value, display shows “Error” and then back to last saved value.  Please set weight as 000.000 kg and quantity as 000000 pcs to cancel Hi and Lo value.  If the weight is less than 20d, check weight function is not activated.  Default settings are marked by * or : Clear : move the cursor leftward : Upward key : move the cursor rightward no ⇒ no beep oK*⇒ Beep within the Hi and Lo value nG ⇒ Beep beyond the Hi or Lo value . kg Please refer to 2-2 to set sampling and average unit weight Or press + or . kg or pcs or pcs or Press key to back to last step

EXCELL PRECISION CO., LTD.

3-2-2 RS-232 Setting (P2 CoM) Press key to select “P2 CoM”. In each setting, Press key to save the setting or press key to exit without saving and back to last setting.  Please see Appendix 1 for output format  Default settings are marked by * : clear : move to left : upward : move to right : confirm : cancel Standard print Transmit mode Baud rate Communication setting Continuous Transmit rate Print type Output format Lab Output format Prt Language Please see 3-2-3 Time display (Option) Real time clock (Option) Please see 3-2-4 Year/month/date Date/month/year RS-485 ID (Option) English Please see 3-2-5 or or or or or or or or Press key to select 0*, 1, 2, 3 Press key to confirm. Press key to select 0*, 1, 2, 3 Press key to confirm. Press key to select n81*, E71 or o71. Press key to confirm. Press key to select 600, 1200, 2400, 4800, 9600*, 19200. Press key to confirm.  For Wireless models, baud rate must be set as 9600 (bits/sec) and Communication protocol must be set as n81.

EXCELL PRECISION CO., LTD.

3-2-3 Transmit Mode Setting After enter RS-232 setting, press key to select transmit mode. After selecting, press key to save the setting and back to last setting (ModE). After all settings finished, press key to back to weighing mode.  Please see Appendix 1 for output format.  Default settings are marked by * Auto accumulate transmit Command mode Continuous transmit Stable transmit (Continuous) Stable transmit (Single)* Press key to transmit 鍵傳輸 Press key to transmit And save in memory Press key to exit and back to weighing mode.

EXCELL PRECISION CO., LTD.

3-2-4 Real Time Clock Setting The cursor stays at the third digits. After entering numbers, press key to save the setting or press key to exit without saving. 3-2-5 Continuous Transmit Rate (rPS) Time setting (year month date): Display last setting. Press key to adjust time. Press or key to move cursor 按 或 鍵移動位置 Press key to save the setting Press key to save the setting and back to RTC setting Display last setting Default setting: Time setting (hour minute seconds): Display last setting. Press key to adjust time. Press or key to move cursor 按 或 鍵移動位置 : clear : move to left : upward : move to right : confirm : cancel Press key to select transmit rate in cycle and press key to save the setting  1 time/sec  2 time/sec  4 time/sec  8 time/sec  16 time/sec  More than16 times/sec (default)  Actual output times vary by hardware implements

EXCELL PRECISION CO., LTD.

3-3 Other Function Settings (P4 oth) Enter other funcfion settings”P4 oth” and press key to enter sub-menue setting. Press Key to select ON or OFF in Animal mode and Auto. average unit weight. After seleting, press key to save the setting or press key to exit without saving. After all settings finished, press key to back to weighing mode.  Animal mode: Use when weighing animals that are in motion. The weight value can be held for maximum weight or when the weight is stable depending on the hold function setting.  Average unit weight: If the weight of the objects on platter > the previous sampling number more than 5 pcs, and also < 200% the previous sampling number, the scale will automatically adjust the unit weight.  Continuous tare: If this function off, it only can be tare for once. It can not be tare until tare cancel; If this function on, ii can be tare continuously except gross weight > capacity.  Default settings are marked by * Press key to save the setting or press key to exit without saving and back to last step. Print Animal mode Average unit weight . kg Tare range Continuous tare or or or or or Foot switch (option) Zero Tare Press key to select ON or OFF*. Press key to save the setting. If it sets ON, in weighing mode, press + key to call up Hold mode. Press key to select ON or OFF*. Press key to save the setting. Press key to select ON* or OFF. Press key to save the setting. Press key to save the setting. Tare range setting: Press key to adjust value. Press or key to move cursor. Press key to save the setting

EXCELL PRECISION CO., LTD.

3-4 Weight Unit Setting (P5 unt) Kg is the primary weight unit. To turn on/off other weight units, please enter weight unit setting “P5 unt” and press key. Press key to select ON or OFF. Press key to save the setting or press key to exit without saving. And then enter next unit setting. Press key to back to weighing mode after all the setting finished. When there is no load on platter in weighing mode, press key for 3 seconds to shift units.  Only one of the “tJ”, “hJ” and "VISS" can be turned on at a time. Before turning one of them on, please make sure the other two are off. Otherwise, the screen will display "Error" to indicate an error has occurred and the setting is not saved. “G”, “Lb”, “oZ” are freely to set as “on” or “off”.  In dual range, viss unit indicator is located in the originally Range1. When Range2 indicator is off, it means currently is in Range 1.  It will display the previous saved setting first. Press key to select ON or OFF. Press key to save the setting. g Press key to select ON or OFF. Press key to save the setting. Press key to select ON or OFF. Press key to save the setting. Press key to select ON or OFF. Press key to save the setting. lb lb/oz Back to g setting Press key to select ON or OFF. Press key to save the setting. Press key to select ON or OFF. Press key to save the setting. Taiiwan Tael H.K.Tael viss

EXCELL PRECISION CO., LTD.

3-5 External calibration (P6 ZCL)  This function is not available for approval models. Enter external calibration”P6 ZCL” and press key to confirm and enter sub-menu or Press key to exit without saving. 3-6 Restore Default Setting (P7 rSt)  This function is not available for approval models. Enter restore default setting “P7 rSt” and press key to restart the scale.  The defaults are included the following: 1) External weight calibration 2) HI/LO/OK setting values 3) Parameters in P1 rEF 4) Sampling settings for the counting function 5) Backlight and autopower off setting Restart the scale automatically Restart and back to weighing mode . kg . kg 0 1 Display last setting. Press key to adjust value. Press or key to move cursor Press key to save the setting or press key to exit without saving and back to last step.

EXCELL PRECISION CO., LTD.

Chapter 4 Wireless Connection Instruction  Baud rate must be set as 9600 (bits/sec) and Communication protocol must be set as n81. Step 1: Connect to your device 1. Enable Wireless on your computer. Right-click on the icon of the bottom-right corner on taskbar, highlight “New Connection” and left click. Due to the different bluetooth supplier software could be installed, the setting dialogs shown below are just for reference. 2. Check “My device is set up and ready to be found” in the dialogue box.

EXCELL PRECISION CO., LTD.

3. If the device is ready, the device names Device-C1 or C2 will be found. Double-click on Device-C1 or Device-C2. 4. Circle “Let me choose my own passkey”, input the passkey “111111” and click “Next > ” button

EXCELL PRECISION CO., LTD.

5. Device is added so far. Please disconnect COM port and click “Finish.” Step 2: Connection test To test the connection, use HyperTerminal recommended in Windows XP 1. go “START” → “All programs” → “Accessories“→ “Communications“→ “HyperTerminal”

EXCELL PRECISION CO., LTD.

2. Key in a name and select icon, then press “OK.” 3. After select the COM port referred by step 1 point 5 and click “OK.”

EXCELL PRECISION CO., LTD.

4. Click “File” → “Properties” 5. Select “settings” from the menu, and click “ASCII setup” on the bottom of the box.

EXCELL PRECISION CO., LTD.

6. Check “Send line ends with line feeds” and “Echo typed characters locally” and click “OK”. 7. Key in commands such S、W、T、Z、P… in the main screen to test...

EXCELL PRECISION CO., LTD.

Appendix 1 Output Format (A). Accumulate output format (ModE = Auto or Pr2) Lab Prt 0 1 2 3 0 1 2 3 Quantities output format

EXCELL PRECISION CO., LTD.

(B). Continous/keys/command Output format , _/ k g CR LF Head 1 Head 2 data unit stop Symbole description: ST Stable value US Unstable value G Gross weight N Net weight T Tare weight NO Number weighing processes C Total of all individual weighings Space line PCS Quantities (C). Remote control Instructions Command Function description Printout examples S Stable Weighing value for the weight is sent via the RS-232 interface W Weighing value for the weight (stable or unstable) is sent via the RS-232 interface T No data are sent, the balance carries out the tare function - Z No data are sent, the balance carries out the tare function - P Quantity will be sent via the RS-232 interface

EXCELL PRECISION CO., LTD.

Appendix 2 ASC II Code Table Symbol ASC II Code Symbol ASC II Code Symbol ASC II Code A 41H a 61H 0 30H B 42H b 62H 1 31H C 43H c 63H 2 32H D 44H d 64H 3 33H E 45H e 65H 4 34H F 46H f 66H 5 35H G 47H g 67H 6 36H H 48H h 68H 7 37H I 49H i 69H 8 38H J 4AH j 6AH 9 39H K 4BH k 6BH  0DH L 4CH l 6CH M 4DH m 6DH N 4EH n 6EH O 4FH o 6FH P 50H p 70H Q 51H q 71H R 52H r 72H S 53H s 73H T 54H t 74H U 55H u 75H V 56H v 76H W 57H w 77H X 58H x 78H Y 59H y 79H Z 5AH z 7AH

EXCELL PRECISION CO., LTD.

Appendix 3 7-Segment Display Characters Number Display Letter Display Letter Display 0 A N 1 B O 2 C P 3 D Q 4 E R 5 F S 6 G T 7 H U 8 I V 9 J W K X L Y M Z

EXCELL PRECISION CO., LTD.

Appendix 4 Wiring Instructions Load cell wiring method (1) As shown below, when a load cell is connected with a 4PIN cable, SEN+ and SEN- can be unconnected. J11 and J12 on PCB must be tin-soldered in short circuit. (2) If Load Cell is 6PIN, please wire as the following diagram

EXCELL PRECISION CO., LTD.

RS-232 Wiring instruction To connect RS232, please open the housing, RS-232’s PIN connectors locate on the bottom-right corner of the main board. The most common connection method is using 9PIN and 25PIN, as shown below PC PIN Function Female 9 PINS Function QWS/GWS 2 Transmit Data SG 3 Receive Data RxD 5 Signal Ground TxD Printer PIN Function Male 25 PINS Function QWS/GWS 2 Receive Data SG 3 Transmit Data RxD 7 Signal Ground TxD RS-485 Wiring instruction To connect RS-485, please make J17, J18 short and J15, J16 open on main board. PC PIN Function Female 9 PINS Function QWS/GWS 2 Transmit Data SG 3 Receive Data DA 5 Signal Ground DB Printer PIN Function Male 25 PINS Function QWS/GWS 2 Receive Data SG 3 Transmit Data DA 7 Signal Ground DB To use other connection methods, please identify the signal and following the above principles. After it is finished, please install the housing by the instruction in the SPECIAL NOTICE.