USER MANUAL
Model MA440 400A AC Clamp Meter DMM
Model MA443 True RMS 400 AC Clamp Meter DMM
Model MA445 True RMS 400A AC/DC Clamp Meter DMM
MA44x‐en‐GB_V1.0 8/16
2
Introduction
Thank you for selecting the Extech EX44x Series 400A Clamp Meter.
The MA440 is a 400A AC Clamp meter with a total of 9 functions.
The MA443 is a 400A True RMS AC Clamp meter that offers 10 functions including TRMS AC
measurements and Type K Thermocouple
The MA445 is a 400A AC/DC True RMS Clamp meter with 11 functions including DC Current, TRMS
AC measu
MA44x‐en‐GB_V1.0 8/16
3
WARNINGS
WARNINGS identify hazardous conditions and actions that could cause BODILY HARM or DEATH.
1.
Before use, check the clamp meter and probe for damage or abnormal operation. Do not use the meter
if probe insulation damage, meter display problems, abnormal meter functioning, etc. is observed.
2.
Never use the meter with the battery compartment open or with the mete
MA44x‐en‐GB_V1.0 8/16
4
CAUTIONS
CAUTIONS identify conditions and actions that could cause DAMAGE to the meter or equipment
under test. Do not expose the meter to extremes in temperature or high humidity.
Safety Symbols
This symbol, adjacent to another symbol, indicates the user must refer to the
manual for further information.
Risk of electrical shock
Alert beeper
Equipment protected by double or�
MA44x‐en‐GB_V1.0 8/16
5
Description
Meter Description
1.
Transformer current jaws
2.
Jaw opening trigger
3.
M (Mode) button
4.
Backlit LCD
5.
Control buttons (see descriptions below)
6.
COM negative input terminal
7.
Positive input terminal
8.
Function selector
9.
NCV alert symbol
10.
Backlight button (MA440) or Work Light button
(MA443 and MA445)
11.
NCV sensor
Note: Battery compartment is located on back of m
MA44x‐en‐GB_V1.0 8/16
6
Control Buttons
Mode button: Short presses to step through the mode options for the selected
measurement function
HOLD and Backlight button (MA443/MA445): Short press to freeze/unfreeze reading.
Long press to turn backlight ON or OFF. Note that the backlight button is in the upper
right side of the meter for the MA440 (see Side Button description below)
HOLD button (MA440
MA44x‐en‐GB_V1.0 8/16
7
Operation
CAUTIONS
Read and understand all of the Safety statements listed in the safety section of this manual
prior to use.
Powering the Meter
1.
Move the function switch to any position to power the meter. Check the batteries if the unit
fails to power ON.
2.
Move the function switch to the OFF position to remove power to the meter.
3.
The meter has an Auto Power O
MA44x‐en‐GB_V1.0 8/16
8
AC Current Measurements
WARNING: Do not handle the meter above the finger/hand guard barrier.
CAUTION: Observe CAT III 600V with respect to Earth Ground for the Jaw.
1.
Rotate the function switch to the AC Current position (
for MA443 and MA445 or 4
/40
/400
for the MA440). For the MA440 start with the highest range setting (400A) and
step down to lower ranges as
MA44x‐en‐GB_V1.0 8/16
9
DC Current Measurements (MA445)
WARNING: Do not handle the meter above the finger/hand guard barrier.
CAUTION: Observe CAT III 600V with respect to Earth Ground for the Jaw.
CAUTION: Measure in the temperature range of 0 ~ 40oC only.
1.
Rotate the function switch to the DC Current position
.
2.
The A and the DC symbols will appear on the display indicating DC Amperes
MA44x‐en‐GB_V1.0 8/16
10
AC and DC Voltage Measurements
WARNING: Do not apply > 600VAC/DC between the meter terminals and ground.
CAUTION: When connecting the test leads to the circuit or device under test, connect
the black lead before the red lead; when removing the test leads, remove the red lead before
the black lead.
1.
Set the function select switch to the Voltage position
.
2.
Use the
WARNING: Please remove power to the circuit under test and discharge all capacitors
before taking resistance or continuity measurements. The meter will display OL if the circuit
under test is an open circuit of if the measurement exceeds the maximum range of the meter.
Do not input a voltage >30V AC or DC.
1.
Turn the function switch to the Resistance Ω position.
2.
Use the M (mode) button to selec
Extech Instruments Measuring Instruments Owners Instructions:
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated |
|---|---|---|---|---|---|---|
407119 |
User Guide: Extech Instruments 407119 (MN5WYV, Upd.26-04-2026) |
7 | 96 | 21 | 26-04-2026 | |
EA33 |
Extech Instruments Measuring Instruments Operation & user’s manual (File: PDF, 29-05-2026) |
9 | 972 | 166 | 29-05-2026 | |
LT250W |
Measuring Instruments #517IJ6 |
8 | 791 | 167 | 13-05-2026 | |
SDL300 |
PDF Manual (@T18FP9), Extech Instruments SDL300 Measuring Instruments (08-10-2026) |
13 | 401 | 77 | 08-10-2026 | |
GRT300 |
PDF Guide (@YXE22N), Extech Instruments GRT300 Measuring Instruments (12-04-2026) |
9 | 1387 | 333 | 12-04-2026 | |
380340 |
Extech Instruments 380340 User Manual (Operation & user’s manual), @JHD95C |
6 | 0.12 Mb | 818 | 131 | 10-05-2026 |
407736 |
Measuring Instruments #4B4OKS |
5 | 722 | 130 | 07-06-2026 | |
lcr200 |
PDF User Guide (@21J3X4), Extech Instruments lcr200 Measuring Instruments (15-06-2026) |
10 | 42 | 11 | 15-06-2026 |