TRACER CH532 offers customer the

possibility to use inputs or outputs in order to: - use an external water setpoint reset using an analog input (refer to figure 3) - use an auxiliary setpoint - connect a remote on/off of the unit or a circuit - reset faults - connect a remote Cooling/Heating switch - return a circuit fault Note: External water setpoint Based on a external signal input, it will be possible to offset the active setpoint from 0°C to 20°C. This function can be used in conjunction with the automatic setpoint reset function. Figure 3 1. Leaving water temperature set ...

Table 4 - Status, warnings and alarm messages

No Message Reset Type Unit status Description 1 No Alarm - Unit On See unit status on Main display 2 Ext. Ckt1 Stop - Circuit 1 Off Circuit 1 Off by Digital Input (Dual circuit units) 3 Ext. Ckt2 Stop - Circuit 2 Off Circuit 2 Off by Digital Input (Dual circuit units) 4 User Ckt1 Stop - Circuit 1 Off Circuit 1 Disable by Settings (via keyboard) 5 User Ckt2 Stop - Circuit 2 Off Circuit 2 Disable by Settings (via keyboard) 6 Remote Ckt1 Stop - Circuit 1 Off Circuit 1 Disable by Supervision 7 Remote Ckt2 Stop - Circuit 2 Off Circuit 2 Disable by Super ...

Customer settings menu:

“Settings” From the menu screen, select “Settings” then press . Following screen will appear: Enter password:”0000” (factory-set) Press and cursor will move to first field of password. Pressing or will change the value from 0 to 9999. Keeping pressure on or will move the numbers fast. Press to confirm password. Pressing will allow navigation from screen 1 to 5 as shown hereafter: 1. Setpoints To access one of the parameters displayed, press and change value using or . Confirm the value by pressing Cooling Stp = Cold water setpoint (-12 to 20� ...

Table 4 - Status, warnings and alarm messages

No Message Reset Type Unit status Description 1 No Alarm - Unit On See unit status on Main display 2 Ext. Ckt1 Stop - Circuit 1 Off Circuit 1 Off by Digital Input (Dual circuit units) 3 Ext. Ckt2 Stop - Circuit 2 Off Circuit 2 Off by Digital Input (Dual circuit units) 4 User Ckt1 Stop - Circuit 1 Off Circuit 1 Disable by Settings (via keyboard) 5 User Ckt2 Stop - Circuit 2 Off Circuit 2 Disable by Settings (via keyboard) 6 Remote Ckt1 Stop - Circuit 1 Off Circuit 1 Disable by Supervision 7 Remote Ckt2 Stop - Circuit 2 Off Circuit 2 Disable by Super ...

Trane TRACER CH532 user guide recommended for: TCONTCCMHCM04A, Tracer, Tracer SC, Tracer AH540, CVHE.

⚠️ Download Safety

The Controller Operation & user’s manual (32 pages) is completely safe to download (last scan date: 23/11/2025).

Related PDF Instructions for Trane TRACER CH532:

Controller Equipment: Frequently Requested

Have some Questions about Trane TRACER CH532 Device?

Get valuable and actionable advices from other Trane TRACER CH532 device users. Describe your problem or question, regarding the using of TRACER CH532, in as much detail as possible, and other users will be able to answer you.