G2BFHT2 / GM2BFHT2

INSTRUCTIONS FOR INSTALLATION AND USE 2kW WALL MOUNTED FAN HEATER Please read these instructions carefully before use and keep safe for future reference.

Page 2 of 7

FAN HEATER PARTS DESCRIPTION 1. FAN HEATER 2. OUTLET GRILLE 3. INLET GRILLE 4. WALL MOUNTING BRACKET (separate) 5. TOP WALL MOUNTING BRACKET (hinged) 6. POWER SETTING INDICATORS 7. PULL CORD 8. WALL PLUGS 9. SCREW FIXINGS 10. POWER CORD

Page 3 of 7

IMPORTANT SAFETY INSTRUCTIONS This heater should be installed by a competent person (i.e. a qualified electrician) in accordance with the current edition of the IEE wiring regulations (BS 7671) and appropriate statutory regulations. IF IN DOUBT CONSULT A QUALIFIED ELECTRICIAN This heater has a 2kW maximum rating and is designed for permanent high level wall mounting at a minimum height of 1800mm above the room floor. Before installing the heater check that the supply voltage of the installation matches the voltage marked on the heater. This heater is suitable for use at 230 – 240V 50Hz supply voltages. Safety Warnings • Do not use or install heater outdoors • Do not install the heater directly above or below a fixed socket outlet • Do not cover or obstruct heater grilles as this may cause overheating or fire • Do not use the heater to dry clothes • Do not touch the heater with wet hands • Do not use the heater if it has been dropped or damaged in any way • Do not allow any objects to be inserted in to the heater inlet or outlet grilles • Do not allow young children, the aged or infirm to use the heater without supervision • If the heater supply cord becomes damaged it must be replaced by a qualified person or service engineer • In the event of a fault occurring do not attempt to repair the heater. This must only be carried out by a qualified person or service engineer • There are no user serviceable parts supplied with the heater INSTALLATION Electrical Connection BEFORE COMMENCING ANY INSTALLATION WORK OR MAINTENANCE ALWAYS ENSURE THAT THE ELECTRICAL SUPPLY IS SWITCHED OFF For additional safety, remove the fuse or switch off the circuit breaker for the relevant supply circuit at the main fuse box or consumer unit. Ensure that no one else has access that would enable the supply to be inadvertently reconnected. The supply circuit used for connection of the heater must be appropriate for the rating of the heater and must be protected with a 13A fuse DO NOT CONNECT THE HEATER TO A LIGHTING SUPPLY CIRCUIT Wiring The power supply cord fitted to the heater is coloured as follows: BROWN: LIVE BLUE: NEUTRAL THIS HEATER IS DOUBLE INSULATED AND DOES NOT REQUIRE AN EARTH CONNECTION

Page 4 of 7

This heater must be connected to the fixed wiring using a suitable means of termination. The heater must be wired via a double pole switch having a contact separation of at least 3mm in both the Live and Neutral poles to provide a suitable means of electrical isolation. A 13A double pole switched fused connection unit with a flex outlet is recommended for heater connection, positioned adjacent to the heater and not less than 1800mm from the floor. Bath and Shower Room Installation When installing the heater in a bath or shower room a minimum distance of not less than 600mm must be maintained between the nearest edge of the bath / shower and the heater. A minimum distance of 600mm must also be maintained between the bath / shower and means of heater wiring termination and the double pole switch used for electrical isolation (unless pull cord operated). The heater wiring termination and switch must be positioned adjacent to the heater and not less than 1800mm from the floor. Wall mounting 1. Choose a suitable position on the wall to mount the heater, ensuring minimum mounting height of 1800mm from the floor and 150mm clearance between the heater and ceiling. Also ensure 150mm minimum distance around the heater from any flammable objects (e.g. curtains) as shown in Fig 1. 2. Check to ensure that there are no hidden pipes or cables behind the wall where the heater is to be mounted. 3. Place the wall mounting bracket horizontally on the wall and mark the position of the two holes. 4. Using a suitably sized masonry drill for the wall plugs supplied drill the two holes to the required depth. 5. Secure wall mounting bracket to the wall using two of the fixing screws supplied as shown in Fig 2. 6. With the hinged mounting bracket on the fan heater extended upwards position the fan heater on to the wall mounting bracket ensuring that the two slots on the back of the fan heater are fully located on the two vertical supports on the wall bracket. 7. Mark the position of the hole on the top mounting bracket. 8. Remove fan heater and drill hole to the required depth. 9. Reposition fan heater and secure top mounting bracket with the fixing screw supplied as shown in Fig 2. 10. The fan heater should now be securely fixed to the wall. 11. Cut fan heater power supply cord to the required length for connection to supply fixed wiring termination with appropriate flex-outlet facility. 12. Remove required length of the outer insulation of power supply cord and length of inner conductor insulation from ends of individual conductors to ensure their correct termination and connection to the appropriate terminals.

Page 5 of 7

13. Ensure all connection terminals are tight and that the heater power supply cord is retained by the means of termination used. 14. Ensure that the correct rated fuse is fitted in the fused connection unit. This should be a 13A BS1362 approved fuse. 15. Switch on the circuit breaker or replace the fuse to restore power to the heater. FIG 1.

Page 6 of 7

FIG 2. FAN HEATER OPERATION 1. The fan heater is switched ON using the pull cord. 2. The fan heater is OFF when both power indicators are not illuminated. 3. Pull the pull cord once to operate the fan heater at the lowest heat setting (800W). 4. Pull the pull cord twice to operate the fan heater at the middle heat setting (1200W). 5. Pull the pull cord three times to operate the fan heater at the highest heat setting (2000W), both power indicators are illuminated. 6. Pull the pull cord again to turn off the fan heater. 7. The fan heater design incorporates an automatic safety cut-out which will operate should the fan overheat due to the fan grilles becoming blocked or covered over. 8. The heater and fan motor will stop working in the event of the safety cut-out operating and will automatically start again once the unit has cooled down.

Page 7 of 7

CLEANING & MAINTENANCE 1. The only maintenance required is cleaning of the outside surface of the fan heater. 2. Before cleaning the heater, wait until the heater has first cooled down. Ensure that the heater is switched off and the main supply is disconnected. 3. Use a damp cloth to wipe the outside of the heater. 4. Do not use water, detergents, abrasive cleaning materials or chemical agents (alcohol, petrol etc) to clean the heater. 5. There are no user serviceable parts inside the heater. Qualified service personnel only should carry out any repairs. FAN HEATER GUARANTEE GET guarantees that this fan heater will be free from defects in workmanship and materials for a period of 1 year from the date of purchase. Any product found to have defects in workmanship or material within the period of this guarantee will be replaced free of charge. The conditions of this guarantee are as follows: • The product has been properly maintained. • Defects or damage due to normal wear and tear, accident, misuse, or interference are not included. • The product is made available for inspection, together with proof of purchase. NB. This guarantee does not affect your statutory rights. NOTE: This product should not be disposed of with household waste Please recycle where facilities exist. Check with your local authority for recycling advice. GET Plc, Key Point, 3 – 17 High Street, Potters Bar, Herts EN6 5AJ Helpline telephone No. 0121 565 7770 AR0478 Ed B