HP StorageWorks XP1024 Operating System Configuration Manual
Read Online
Read the HP StorageWorks XP1024 Operating System Configuration Manual online using the built-in PDF viewer.
Text of the manual
HP StorageWorks Disk Array XP
operating system configuration
guide
XP128
XP1024
XP10000
XP12000
sixth edition (July 2005)
part number: A5951-96144
This guide describes the requirements and procedures for connecting the XP family of disk
arrays to an HP e3000 system and configuring the disk array for operation with MPE/iX.
MPE/iX
all-guides.co
m
HP StorageWorks Disk Array XP Operating System Configuration Guide: MPE/iX
Copyright © 2003-2005, Hewlett-Packard Development Company, L.P. All rights reserved.
Hewlett-Packard Company makes no warranty of any kind with regard to this material, including, but not limited
to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be
liable for errors contained herein or for incidental or consequential damages in connection with the furnishing,
performance, or use of this material.
This document contains proprietary information, which is protected by copyright. No part of this document may be
photocopied, reproduced, or translated into another language without the prior written consent of Hewlett-Packard.
The information contained in this document is subject to change without notice.
MPE/iX is a registered trademark of Hewlett-Packard Company.
All other product names mentioned herein may be trademarks of their respective companies.
Hewlett-Packard Company shall not be liable for technical or editorial errors or omissions contained herein. The
information is provided “as is” without warranty of any kind and is subject to change without notice. The warranties
for Hewlett-Packard Company products are set forth in the express limited warranty statements accompanying such
products. Nothing herein should be construed as constituting an additional warranty.
Printed in the U.S.A.
HP StorageWorks Disk Array XP Operating System Configuration Guide: MPE/iX
sixth edition (July 2005)
part number: A5951-96144
About this guide 5
Intended audience 5
Prerequisites 5
Disk arrays 5
Related documentation 6
HP technical support 7
HP sales and authorized resellers 7
HP storage website 8
Document conventions 8
Revision history 9
Warranty statement 10
1
Installation 13
Features and requirements 14
Fibre Channel interface 15
SCSI-FC Fabric Router 15
Device types 16
Failover 16
SNMP configuration 16
RAID Manager command devices 17
Installation procedures 18
Install and configure the disk array 19
Setting the host mode for the disk array ports 19
Setting the System Option Modes 21
Configuring the Fibre Channel ports 22
Contents
HP StorageWorks Disk Array XP Operating System Configuration Guide: MPE/iX
Install the host hardware 24
Installing the host system 24
Installing and configuring the HBAs 24
Fabric zoning and LUN security 25
Multiple operating systems in a shared switch fabric 26
Connect the disk array 27
Determining the paths 28
Storage capacity per path 29
Load the OS software 30
Configure the disk array devices in MPE/iX 31
Configuring with native Fibre Channel disk array attachment 32
Configuring with SCSI-FC fabric router disk array attachment 35
Create volume sets and volumes 39
2
Troubleshooting 41
Error conditions 42
Calling the HP support center 44
A
Disk array device emulations 45
Supported emulations 46
Device type specifications 47
B
Booting from the array 51
Existing MPE/iX 7.5 boot disk is available 54
No existing MPE/iX boot disk available and disk array is direct Fibre
Channel connected 57
No existing MPE/iX boot disk available and disk array is Fibre Channel
switch connected 59
Primary boot path format for Fibre Channel devices 59
Determining the FC N-Port I/O path 60
Glossary 63
Index 67
About this guide
5
About this guide
This guide provides information about:
• Requirements and procedures for connecting an XP disk array to a
host system
• Configuring the disk array for use with the MPE/iX operating system
Intended audience
This guide is intended for system administrators with knowledge of the host
server, the operating system, and XP disk arrays.
Prerequisites
Prerequisites for installing and configuring this product include knowledge
of:
• Disk arrays and RAID technology
• Operating system commands and utilities
Disk arrays
Unless otherwise noted, the term disk array refers to these disk arrays:
HP StorageWorks Disk ArrayXP 128
HP StorageWorks Disk Array XP1024
HP StorageWorks XP10000 Disk Array
HP StorageWorks XP12000 Disk Array
HP StorageWorks Disk Array XP Operating System Configuration Guide: MPE/iX
Related documentation
HP provides these related documents:
• HP StorageWorks Disk Array XP128: Owner’s Guide
• HP StorageWorks Disk Array XP1024: Owner’s Guide
• HP StorageWorks XP10000 Disk Array: Owner’s Guide
• HP StorageWorks XP12000 Disk Array: Owner’s Guide
To locate these documents, to learn more about HP software products, or to
obtain software updates, visit the HP web site:
http://h18006.www1.hp.com/storage/xparrays.html.
Refer to the HP website (http://docs.hp.com/mpeix/all/#Fibre%20Channel)
for the following HP e3000 MPE/iX system documentation:
• HP e3000 MPE/iX System Software Maintenance Manual (Release
C.70.00 or Release C.75.00) [30216-90317 or 30216-90344]
• HP e3000 Fibre Channel Mass Storage Adapters Service and User
Manual [32650-90910]
• “Fibre Channel Device and Adapter Support on HP e3000 Systems” in
the Communicator e3000 MPE/iX Release 7.5 manual (Software
Release C.75.00) [30216-90336]
• SCSI-Fibre Channel Router Installation and User Guide [Document
Number 310-605846]
The following papers located at the HP e3000 “Jazz” documentation
website can be very helpful for installing XP Disk Arrays on the HP e3000.
Installation is described for both the Native Fibre Channel interface and the
SCSI-FC Fabric Router:
• “A Guide to Success with the A5814A-003 SCSI-FC Router”
http://jazz.external.hp.com/mpeha/papers/router_paper01.htm
• “MPE Native Fibre Channel Installation onto an FC LDEV 1”
http://jazz.external.hp.com/mpeha/howto/fc_ldev_one.html
all-guides.co
m
About this guide
7
HP technical support
In North America, call technical support at 1-800-633-3600, available 24
hours a day, 7 days a week.
Outside North America, call technical support at the location nearest you.
The HP web site lists telephone numbers for worldwide technical support
at: http://www.hp.com/support. From this web site, select your country.
Collect the following information before calling:
• Technical support registration number (if applicable)
• Product serial numbers
• Product model names and numbers
• Applicable error messages
• Operating system type and revision level
• Detailed questions
For continuous quality improvement, calls may be recorded or monitored.
HP strongly recommends that customers sign up online using the
Subscriber’s choice web site at http://www.hp.com/go/e-updates.
Subscribing to this service provides you with email updates on the latest
product enhancements, newest drivers, and firmware documentation
updates as well as instant access to numerous other product resources.
HP sales and authorized resellers
To reach HP sales or find a local authorized reseller of HP products, call
1-800-282-6672 or visit the HP How To Buy web site:
http://welcome.hp.com/country/us/en/howtobuy.html
You can also find HP sales and resellers at http://www.hp.com. Click
Contact HP.
HP StorageWorks Disk Array XP Operating System Configuration Guide: MPE/iX
HP storage website
For the most current information about HP StorageWorks XP products,
visit: http://h18006.www1.hp.com/storage/arraysystems.html.
For information about product availability, configuration, and connectivity,
contact your HP support representative.
Document conventions
Convention
Element
Blue text (Figure 1)
Blue text represents a cross-reference. In the online version of this guide,
the reference is linked to the target.
Bold
Bold text represents application names, file names, menu items, dialog
box titles, buttons, key names, field names, and literal values that you
type exactly as shown.
Italics
Italic type indicates that you must supply a value. Italic type is also used
for manual titles.
Blue underlined sans serif
font (www.hp.com)
Underlined, blue text represents a website on the Internet. In the online
version of this guide, the reference is linked to the target.
monospace font
Monospace font denotes user input and system responses, such as output
and messages.
Example
The word “example” in italics denotes an example of input or output.
[ ]
Square brackets indicate an optional parameter.
{ }
Braces indicate that you must specify at least one of the listed options.
|
A vertical bar separates alternatives in a list of options.
About this guide
9
Revision history
September 1999
Open-8 emulation added.
January 2000
Content revised and reorganized.
June 2000
Added support for XP512.
February 2001
Added support for XP48 and SCSI-to-Fibre Channel
router.
June 2003
Changed brand name from Surestore to StorageWorks.
Added support for XP1024 and XP128.
November 2003
Minor update.
November 2004
Added MPE/iX Native FC extension.
July 2005
Updated to include XP10000, Command View XP
Advanced Edition, and Remote Web Console XP.
HP StorageWorks Disk Array XP Operating System Configuration Guide: MPE/iX
Warranty statement
HP warrants that for a period of ninety calendar days from the date of
purchase, as evidenced by a copy of the invoice, the media on which the
Software is furnished (if any) will be free of defects in materials and
workmanship under normal use.
DISCLAIMER. EXCEPT FOR THE FOREGOING AND TO THE
EXTENT ALLOWED BY LOCAL LAW, THIS SOFTWARE IS
PROVIDED TO YOU “AS IS” WITHOUT WARRANTIES OF ANY
KIND, WHETHER ORAL OR WRITTEN, EXPRESS OR IMPLIED.
HP SPECIFICALLY DISCLAIMS ANY IMPLIED WARRANTIES
OR CONDITIONS OF MERCHANTABILITY, SATISFACTORY
QUALITY, NON-INFRINGEMENT, TITLE, ACCURACY OF
INFORMATIONAL CONTENT, AND FITNESS FOR A
PARTICULAR PURPOSE. Some jurisdictions do not allow exclusions
of implied warranties or conditions, so the above exclusion may not apply
to you to the extent prohibited by such local laws. You may have other
rights that vary from country to country, state to state, or province to
province.
WARNING! YOU EXPRESSLY ACKNOWLEDGE AND AGREE
THAT USE OF THE SOFTWARE IS AT YOUR SOLE RISK. HP
DOES NOT WARRANT THAT THE FUNCTIONS CONTAINED IN
THE SOFTWARE WILL MEET YOUR REQUIREMENTS, OR THAT
THE OPERATION OF THE SOFTWARE WILL BE UNINTERRUPTED,
VIRUS-FREE OR ERROR-FREE, OR THAT DEFECTS IN THE
SOFTWARE WILL BE CORRECTED. THE ENTIRE RISK AS TO THE
RESULTS AND PERFORMANCE OF THE SOFTWARE IS ASSUMED
BY YOU. HP DOES NOT WARRANT OR MAKE ANY
REPRESENTATIONS REGARDING THE USE OR THE RESULTS OF
THE USE OF THE SOFTWARE OR RELATED DOCUMENTATION IN
TERMS OF THEIR CORRECTNESS, ACCURACY, RELIABILITY,
CURRENTNESS, OR OTHERWISE. NO ORAL OR WRITTEN
INFORMATION OR ADVICE GIVEN BY HP OR HP’S AUTHORIZED
REPRESENTATIVES SHALL CREATE A WARRANTY.
About this guide
11
LIMITATION OF LIABILITY. EXCEPT TO THE EXTENT
PROHIBITED BY LOCAL LAW, IN NO EVENT INCLUDING
NEGLIGENCE WILL HP OR ITS SUBSIDIARIES, AFFILIATES,
DIRECTORS, OFFICERS, EMPLOYEES, AGENTS OR
SUPPLIERS BE LIABLE FOR DIRECT, INDIRECT, SPECIAL,
INCIDENTAL, CONSEQUENTIAL, PUNITIVE OR OTHER
DAMAGES (INCLUDING LOST PROFIT, LOST DATA, OR
DOWNTIME COSTS), ARISING OUT OF THE USE, INABILITY
TO USE, OR THE RESULTS OF USE OF THE SOFTWARE,
WHETHER BASED IN WARRANTY, CONTRACT, TORT OR
OTHER LEGAL THEORY, AND WHETHER OR NOT ADVISED
OF THE POSSIBILITY OF SUCH DAMAGES. Your use of the
Software is entirely at your own risk. Should the Software prove defective,
you assume the entire cost of all service, repair or correction. Some
jurisdictions do not allow the exclusion or limitation of liability for
incidental or consequential damages, so the above limitation may not apply
to you to the extent prohibited by such local laws.
NOTE. EXCEPT TO THE EXTENT ALLOWED BY LOCAL LAW,
THESE WARRANTY TERMS DO NOT EXCLUDE, RESTRICT OR
MODIFY, AND ARE IN ADDITION TO, THE MANDATORY
STATUTORY RIGHTS APPLICABLE TO THE LICENSE OF THE
SOFTWARE TO YOU; PROVIDED, HOWEVER, THAT THE
CONVENTION ON CONTRACTS FOR THE INTERNATIONAL
SALE OF GOODS IS SPECIFICALLY DISCLAIMED AND SHALL
NOT GOVERN OR APPLY TO THE SOFTWARE PROVIDED IN
CONNECTION WITH THIS WARRANTY STATEMENT.
all-guides.co
m
You and your HP service representative each play a role in installation.
Your HP service representative is responsible for installing the disk array
and formatting the disk devices. You are responsible for configuring the
host server for the new devices with assistance from your HP service
representative.
HP StorageWorks Disk Array XP Operating System Configuration Guide: MPE/iX
Features and requirements
Ask your HP service representative about the latest supported hardware and
software.
The disk array has the following features:
• Storage capacity. The storage capacity for each model is listed below:
XP128: From 8 to 128 drives for up to 18 TB, 48 FC ports
XP1024: From 8 to 1024 drives for up to 149 TB, 64 FC ports
XP10000: Up to 240 drives for up to 69.2 TB, 48 FC ports
XP12000: Up to 1152 drives for up to 165 TB, 128 FC ports
• Server support. HP e3000: A-Class, N-Class, Series 9x8, Series 9x9, and
Series 99x
• Operating system support. MPE/iX Operating System, Release 7.0
Express 1 with patch MPEMX36, or Release 7.5
Before installing the disk array, ensure the environment conforms to these
requirements::
• Fibre Channel host adapters (for A-Class and N-Class only) or HVD
SCSI adapters (for Series 9x8, Series 9x9, and Series 99x system
models). Refer to the adapter documentation for installation. Use of SCSI
adapters also requires SCSI-FC Fabric Routers as described later in this
document.
•
(Recommended) HP StorageWorks Remote Web Console XP, Command
View XP Advanced Edition or Command View XP with LUN management
feature for configuring disk array ports and paths
(Recommended) HP StorageWorks LUN Configuration and
Security Manager XP
• (Optional) Other available XP software (some may not be
supported by your system):
HP StorageWorks Business Copy XP
HP StorageWorks Continuous Access XP
HP StorageWorks Continuous Access Extension XP
HP StorageWorks Auto LUN XP
HP StorageWorks Data Exchange XP
HP StorageWorks Resource Manager XP
HP StorageWorks RAID Manager XP
HP StorageWorks Cache LUN XP
HP StorageWorks Auto Path XP
HP StorageWorks Cluster Extension XP
HP StorageWorks Performance Advisor XP
Fibre Channel interface
The MPE/iX host can use the A7895A 2 Gbps Fibre Channel HBA to
connect to the disk array. The disk array port should not use auto negotiate
to detect the speed of the host Fibre Channel adapter. Configure it "hard" to
either 1 or 2 Gbps.
Even though the interface is Fibre Channel, this guide uses the term “SCSI
disk” because disk array devices are defined to the host as SCSI disks.
SCSI-FC Fabric Router
The HP e3000 supports the A5814A-003 SCSI-FC Fabric Router hardware,
which enables an HP e3000 with HVD SCSI HBAs to connect to a disk
array with a Fibre Channel interface. The router converts data between the
SCSI I/O interface at the host server and the Fibre Channel I/O interface at
the disk array.
HP StorageWorks Disk Array XP Operating System Configuration Guide: MPE/iX
Device types
The HP e3000 system supports only OPEN-x device types. LUSE and CVS
device types are not supported.
Failover
The XP family of disk arrays supports many standard software products
that provide host, application, or I/O path failover and management.
The HP e3000 system supports I/O path failover for the disk arrays by
means of the MPE/iX High Availability FailOver/iX software product.
SNMP configuration
The XP family of disk arrays supports standard Simple Network
Management Protocol (SNMP) for remotely managing the disk array. The
SNMP agent on the SVP performs error-reporting operations requested by
the SNMP manager. SNMP properties are usually set from the SVP but
they can also be set remotely using Remote Web Console XP, Command
View XP, or Command View XP Advanced Edition. Refer to the
applicable user’s guide for procedures.
Refer to the operating system documentation to configure the SNMP
manager on the host.
all-guides.co
m
RAID Manager command devices
RAID Manager manages Business Copy (BC) or Continuous Access (CA)
operations from a host server. To use RAID Manager with BC or CA, you
use Remote Web Console, Command View, or Command View XP
Advanced Edition to designate at least one LDEV as a command device.
Refer to the applicable user’s guide for information about how to designate
a command device.
Caution
An LDEV designated as a command device cannot contain any MPE/iX
files or data. Create a single member volume set through the VOLUTIL
utility program. Then VSCLOSE it, SCRATCHVOL it, and convert it to a
command device.
HP StorageWorks Disk Array XP Operating System Configuration Guide: MPE/iX
Installation procedures
Perform these actions to install and configure the disk array:
1. Install and configure the disk array (see page 19)
• Setting the host mode for the disk array ports
• Setting the System Option Modes
• Configuring the Fibre Channel ports
2. Install the host hardware (see page 24)
• Installing the host system
• Installing and configuring the HBAs
• Fabric zoning and LUN security
• Multiple operating systems in a shared switch fabric
3. Connect the disk array (see page 27)
• Determining the paths
• Storage capacity per path
4. Load the OS software (see page 30)
5. Configure the disk array devices in MPE/iX (see page 31)
• Configuring with native Fibre Channel disk array attachment
• Configuring with SCSI-FC fabric router disk array attachment
6. Create volume sets and volumes (see page 39)
Install and configure the disk array
The HP service representative performs these tasks:
• Assembling hardware and installing software
• Loading the microcode updates
• Installing the channel adapters (CHAs) and cabling
• Installing and formatting devices
After these tasks are finished, you will use Remote Web Console,
Command View, Command View XP Advanced Edition, or LUN
Configuration and Security Manager to complete the remaining tasks listed
below. If you do not have these programs, your HP service representative
can perform these tasks for you.
Setting the host mode for the disk array ports
The disk array ports have host modes that must be set depending on the
host you use. After the disk array is installed use LUN Manager in Remote
Web Console XP (shown), Command View XP, or Command View XP
Advanced Edition to set the host mode for each port.
The host mode setting for MPE/iX is 08.
HP StorageWorks Disk Array XP Operating System Configuration Guide: MPE/iX
For the XP1024/XP128 arrays, the host mode can also be set at the port
information window in Command View XP AE.
Setting the System Option Modes
The HP service representative sets the System Option Mode(s) based on the
operating system and software configuration of the host.
Mode
Level
HA
Software
Description and Usage
140
Optional
None
ON: Response to the Inquiry command is
changed, and the volume can be used from
VeritasNetBackUP in heterogeneous OS
configuration, such as HP-UX.
OFF: Normal response to the Inquiry
command.
186
Mandatory
Veritas
Database
Editions/
Advanced
Cluster
ON: Mandatory setting when VERITAS
Database Editions/Advanced Cluster is
connected.
OFF: VERITAS Database Editions/Advanced
Cluster should not be connected with this
setting.
254
Optional
Veritas
Database
Editions
Change the response of reserve conflict status
to Read Capacity, Verify, and Start Stop Unit.
ON: Normal end is reported.
OFF: Reserve conflict status is reported.
280
Optional
HP-UX Ghost LUN Remove
OS version: HP-UX 11.0 and later.
ON: When the host scans the LUNS on the
port, the disk array is not represented in the
device list for HP-UX.
OFF: When the host scans the LUNS on the
port, the disk array is represented in the device
list for HP-UX.
all-guides.co
m
HP StorageWorks Disk Array XP Operating System Configuration Guide: MPE/iX
Configuring the Fibre Channel ports
Configure the disk array Fibre Channel ports by using Remote Web
Console (shown), Command View, or Command View XP AE. Select the
settings for each port based on your storage area network topology. Use
switch zoning if you connect different types of hosts to the array through
the same switch.
Fibre address
In fabric environments, the port addresses are assigned automatically. In
arbitrated loop environments, set the port addresses by selecting a unique
arbitrated loop physical address (AL-PA) or loop ID for each port.
Fabric and connection parameter settings
For HP e3000 systems, set the port topology to FABRIC ON and the
connection parameter to FC-AL. This provides an NL-port on the disk
array (public arbitrated loop) and is the recommended supported topology.
HP StorageWorks Disk Array XP Operating System Configuration Guide: MPE/iX
Install the host hardware
This section explains how to install and configure the host and host bus
adapters (HBAs) that connect the host to the disk array.
If you plan to use Fibre Channel switches to create a SAN environment,
install them according to the manufacturer's instructions.
If you plan to connect to the disk arrays using HP e3000 SCSI HBAs (HVD
required), install the required A5814A-003 SCSI-FC Fabric Routers
according to the instructions in the SCSI-Fibre Channel Router Installation
and User Guide.
When you are configuring the fabric switch for use with routers, make sure
that you configure initiator zoning. (See Jazz article “A guide to Success
with the A5814A-003 SCSI-FC Router,” referenced on page 6.)
Installing the host system
Install the host system following the HP e3000 system installation
instructions.
Installing and configuring the HBAs
Install and configure the host bus adapter cards using the HP HBA
installation instructions, driver software, and setup utilities.
When you are installing A6795A Fibre Channel HBAs on A-Class and
N-Class systems, be sure to record the I/O slot paths where you install the
cards. You will need the I/O paths of these HBAs later during the I/O
configuration procedure. For SCSI HBA installations, recording the I/O
paths is not required. You can determine those I/O later using the
MAPPER/MAPPER2 facility.
Fabric zoning and LUN security
If you plan to use clustering, install and configure the clustering software
on the servers.
Clustering is the organization of multiple servers into groups. Within a
cluster, each server is a node. Multiple clusters compose a multi-cluster
environment. The following example shows a multi-cluster environment
with three clusters, each containing two nodes. The nodes share access to
the disk array.
Within the Storage Area Network (SAN), the clusters may be
homogeneous (all the same operating system) or they may be
heterogeneous (mixed operating systems). How you configure LUN
security and fabric zoning depends on the operating system mix and the
SAN configuration.
HP StorageWorks Disk Array XP Operating System Configuration Guide: MPE/iX
Multiple operating systems in a shared switch fabric
By using appropriate zoning and LUN security, you can connect multiple
clusters with multiple operating systems to the same switch and fabric.
Environment
OS Mix
Fabric Zoning
LUN Security
Standalone SAN
(non-clustered)
homogeneous (a single OS
type present in the SAN)
Not required
Must be used when multiple
hosts connect through a
shared port
heterogeneous (more than one
OS type present in the SAN)
Required
Clustered SAN
homogeneous (a single OS
type present in the SAN)
Not required
Must be used when multiple
cluster nodes connect through
a shared port
heterogeneous (more than one
OS type present in the SAN)
Required
Multi-Cluster
SAN
homogeneous (a single OS
type present in the SAN)
Not required
Must be used when multiple
cluster nodes connect through
a shared port
heterogeneous (more than one
OS type present in the SAN)
Required
all-guides.co
m
Connect the disk array
The HP service representative connects the disk array to the HP e3000 host
by:
1. If connecting SCSI cables, shutting down and powering off the host.
2. Verifying operational status of the disk array channel adapters, LDEVs,
and paths.
3. Connecting the I/O cables between the disk array and the host. Fibre
Channel cables run from the disk array to either the host system (direct
native Fibre Channel connection), a Fibre Channel switch (fabric Fibre
Channel connection), or to an A5814A-003 SCSI-FC Fabric Router
(host SCSI to disk array Fibre Channel connection). If you use a
SCSI-FC Router, run SCSI I/O cables from the router to the host system.
4. Powering on all peripherals if they were turned off.
5. Powering on and booting up the host if it was turned off.
6. Verifying the ready status of the disk array and peripherals.
HP StorageWorks Disk Array XP Operating System Configuration Guide: MPE/iX
Determining the paths
Use Remote Web Console (shown), Command View, or Command View
XP AE to define paths (LUNs) between hosts and volumes in the disk
array.
This process is also called “LUN mapping.” In Remote Web Console and
Command View, LUN mapping includes:
•
Configuring ports
•
Setting LUN security
•
Creating host groups
•
Assigning host bus adapter WWNs to host groups
•
Mapping volumes to host groups (by assigning LUNs)
In Command View XP AE, LUN mapping includes:
•
Configuring ports
•
Creating storage groups
•
Mapping volumes and WWN/host access permissions to the
storage groups
For details see LUN Configuration and Security Manager User’s Guide or
Command View XP Advanced Edition Device Manager Web Client User’s
Guide. Note the LUNS and their ports, WWNs, nicknames, and LDEVs for
later use in verifying host and device configuration.
Storage capacity per path
An important difference between MPE/iX and other operating systems
(such as HP-UX) is the determination of disk capacity on a path. MPE/iX is
very sensitive to spindle count (LUNs) per path. If this count exceeds 16
per bus or path, performance problems may result.
To determine the available storage capacity in a path, subtract required
system and application I/O space from the total disk capacity and divide the
result by the spindle count (number of LUNs) in the path.
If performance information isn't available, create a configuration similar to
the installation you had before migrating to the XP array, but be sure not to
exceed 16 LUNs per path. Exceeding this number may cause MPE/iX to
issue more I/O requests than the XP array can service.
HP StorageWorks Disk Array XP Operating System Configuration Guide: MPE/iX
Load the OS software
For an existing host requiring an OS update before installing the array,
follow the instructions in the HP e3000 MPE/iX System Software
Maintenance Manual to install or to update the OS.
The OS must be MPE/iX 7.0 or MPE/iX 7.5.
If you are installing a new MPE/iX OS onto an XP disk array that will serve
as the boot disk (MPE/iX Ldev 1), refer to Appendix C. The appendix
provides for instructions on obtaining the required primary boot path of
that disk array device. Setting the primary boot path into the processor’s
PDC memory is a required first step for OS software installation.
If, however, you are installing or updating an OS not using a newly
connected XP disk array as Ldev 1, determine the primary boot path by the
normal HP e3000 methods (for example, ODE> run MAPPER or
MAPPER2 or by using fcscan).
Configure the disk array devices in MPE/iX
Use either the SYSGEN utility program or the IOCONFIG utility command
to perform I/O configuration of the new XP disk array devices for the
MPE/iX OS.
The SYSGEN utility allows you to prepare a new I/O configuration for the
system, but the new configuration does not take effect until the system is
rebooted.
The IOCONFIG command prepares a new I/O configuration and puts it
into effect immediately, while the system is up, without a reboot.
Both configuration utilities execute in the normal MPE/iX system
environment while the system is up and running. Therefore you must boot
and start the OS from the MPE/iX Ldev 1 boot disk before you can perform
configuration.
For a pre-existing system to which new XP disk array devices are being
added, you will already have an operable system on an existing Ldev 1 boot
disk that you can start up. For a newly installed system, boot the system
from the primary boot path just used to install the system, and start the OS
using the appropriate factory configuration group, as described in the
System Software Maintenance Manual.
Regardless of which configuration utility you choose, you must determine
the system I/O paths of the XP disk array devices’ internal LUNs in order to
add those devices to the system I/O configuration.
The procedure to determine the I/O paths depends on the I/O interface
attachment method for your system:
• Native Fibre Channel (A-Class and N-Class systems running
MPE/iX 7.5)
OR
• SCSI-FC Fabric Router (available for all systems).
all-guides.co
m
HP StorageWorks Disk Array XP Operating System Configuration Guide: MPE/iX
Follow the procedure below that applies to your system:
• "Configuring with native Fibre Channel disk array attachment"
(page 32)
• "Configuring with SCSI-FC fabric router disk array attachment"
(page 35)
Configuring with native Fibre Channel disk array attachment
For native Fibre Channel attachment of disk arrays, MPE/iX Release 7.5
provides the new fcscan utility which is capable of determining the I/O
paths (both in SYSGEN and in PDC formats) for the disk arrays. Before
fcscan can do this, the I/O paths of the Fibre Channel HBAs must first be
configured in MPE/iX, using either SYSGEN or IOCONFIG.
This is the overall procedure for configuring disk arrays with Fibre Channel
attachment:
• Boot and start the system.
• Use SYSGEN or IOCONFIG to configure the I/O paths of the Fibre
Channel HBAs. (Your recorded these I/O paths when you installed
the HBAs into the system.)
• Use fcscan -h to determine the I/O paths for the disk arrays’ N-ports
and LUNs. Using fcscan also verifies disk array device recognition.
• Use SYSGEN or IOCONFIG to I/O configure the disk arrays’
N-ports and LUNs.
After completing the I/O configuration procedure, create MPE/iX volume
sets and disk volumes on the configured XP disk array devices.
The following sample I/O configuration procedure uses IOCONFIG to
perform immediate I/O configuration and fcscan –h to determine device
paths for native Fibre Channel attachment of XP disk arrays. In this
example there are two XP disk arrays, each routed through a SAN FC
switch, and then each attached to an A6795A Fibre Channel HBA on the
server host. The procedure begins after the system has been booted and
started, and for brevity only two LUNs within each XP disk array are
shown being configured by IOCONFIG.
Further detailed information about determining I/O paths for Fibre Channel
disk arrays can be found in the HP e3000 Fibre Channel Mass Storage
Adapters Service and User Manual, and in the MPE/iX Release 7.5
Communicator article “Fibre Channel Device and Adapter Support on HP
e3000 Systems.”
1. With the system booted up, use IOCONFIG to configure the I/O paths
for the Fibre Channel HBAs (located at paths 0/4/0/0 and 0/6/0/0 in this
example):
CSYLE18:ioconfig
IOCONFIG A.00.00 (catalog A.00.00) (c) 1994 Hewlett-Packard Co. All Rights Reserved MON,
AUG 23, 2004, 5:29 PM
ioconfig:apath path=0/4; id=pat_pci_bc
ioconfig:apath path=0/6; id=pat_pci_bc
ioconfig:apath path=0/4/0; id=pci_device
ioconfig:apath path=0/6/0; id=pci_device
ioconfig:apath path=0/4/0/0; id=a6795a
td: claimed Tachyon XL2 Fibre Channel Mass Storage card at 0/4/0/0
Scanning for fibre channel devices at 0/4/0/0. This may take a while...
ioconfig:apath path=0/6/0/0; id=a6795a
td: claimed Tachyon XL2 Fibre Channel Mass Storage card at 0/6/0/0
Scanning for fibre channel devices at 0/6/0/0. This may take a while...
ioconfig::exit
keeping to group CONFIG.SYS
Purge old configuration (yes/no)?Automatic yes
** configuration files successfully saved **
CSYLE18:
2. Use fcscan –h to determine the SYSGEN I/O paths for the disk arrays
that are attached through HBAs at 0/4/0/0 and 0/6/0/0:
CSYLE18:fcscan -h
FCSCAN Version 1.1
Scanning for Fibre Channel devices.
This could take upto few minutes. Please wait ...
FCSCAN has found the following Fibre Channel I/O Adapter Cards and Devices on this
system.
SYSGEN PATH DESCRIPTION BOOT MENU PATH
============= ============= ================
0/4/0/0 Fibre Channel Adapter
0/4/0/0.70962 Fibre Channel N-Port
0/4/0/0.70962.0 HP OPEN-3 disk 0/4/0/0.1.21.50.0.0.0
0/4/0/0.70962.1 HP OPEN-3 disk 0/4/0/0.1.21.50.0.0.1
0/4/0/0.70962.2 HP OPEN-3 disk 0/4/0/0.1.21.50.0.0.2
0/6/0/0 Fibre Channel Adapter
0/6/0/0.70962 Fibre Channel N-Port
0/6/0/0.70962.0 HP OPEN-3 disk 0/6/0/0.1.21.50.0.0.0
0/6/0/0.70962.1 HP OPEN-3 disk 0/6/0/0.1.21.50.0.0.1
0/6/0/0.70962.2 HP OPEN-3 disk 0/6/0/0.1.21.50.0.0.2
CSYLE18:
3. Use IOCONFIG to I/O configure the Fibre Channel N-Ports and the XP
disk array LUNs as MPE/iX Ldevs:
CSYLE18:ioconfig
IOCONFIG A.00.00 (catalog A.00.00) (c) 1994 Hewlett-Packard Co. All Rights Reserved MON,
AUG 23, 2004, 5:38 PM
HP StorageWorks Disk Array XP Operating System Configuration Guide: MPE/iX
ioconfig:apath path=0/4/0/0.70962; id=fc_nport
ioconfig:adev ldev=100; path=0/4/0/0.70962.0; id=hpdarray
Class(es) updated, so rerun asoctbl.pub.sys to recreate asociate.pub.sys.
BEGIN VOLUME MOUNTING ON LDEV 100 (AVR 9
UNKNOWN VOLUME MOUNTED ON LDEV 100 (AVR 15)
ioconfig:adev ldev=101; path=0/4/0/0.70962.1; id=hpdarray
Class(es) updated, so rerun asoctbl.pub.sys to recreate asociate.pub.sys.
BEGIN VOLUME MOUNTING ON LDEV 101 (AVR 9
UNKNOWN VOLUME MOUNTED ON LDEV 101 (AVR 15)
ioconfig:apath path=0/6/0/0.70962; id=fc_nport
ioconfig:adev ldev=200; path=0/6/0/0.70962.0; id=hpdarray
Class(es) updated, so rerun asoctbl.pub.sys to recreate asociate.pub.sys.
BEGIN VOLUME MOUNTING ON LDEV 200 (AVR 9)
UNKNOWN VOLUME MOUNTED ON LDEV 200 (AVR 15)
ioconfig:adev ldev=201; path=0/6/0/0.70962.1; id=hpdarray
Class(es) updated, so rerun asoctbl.pub.sys to recreate asociate.pub.sys.
BEGIN VOLUME MOUNTING ON LDEV 200 (AVR 9)
UNKNOWN VOLUME MOUNTED ON LDEV 200 (AVR 15)
ioconfig:exit
keeping to group CONFIG.SYS
Purge old configuration (yes/no)?Automatic yes
** configuration files successfully saved **
CSYLE18:
4. Confirm with the DSTAT command and then create volume sets and
volumes on the new XP disk array devices.
Configuring with SCSI-FC fabric router disk array attachment
Configure disk array devices attached through the SCSI-FC Fabric Router
in the same way as for other SCSI disk devices. No special MPE/iX
configuration steps are required. However, before proceeding read the
guidelines in the "Jazz Router Paper" cited on page 6.
Use the MAPPER (or MAPPER2 for A-Class and N-Class) I/O mapping
utility program in the Offline Diagnostic Environment (ODE) to display the
I/O paths for the SCSI HBAs and the disk array devices (targets and
LUNs). Then use either SYSGEN or MPE/iX’s IOCONFIG utility
command and the I/O paths reported by MAPPER to perform the MPE/iX
I/O configuration of SCSI HBAs and disk Ldevs.
To configure disk array devices attached by SCSI-FC Fabric Router:
1. Boot the system to the ISL> prompt on the primary boot path.
2. Invoke the ODE (Offline Diagnostic Environment) system from the
ISL> prompt.
3. Run the MAPPER (or MAPPER2 for A- and N-Class systems) I/O
mapping utility within ODE.
Running MAPPER will verify that the disk array devices are
recognized by the host system. MAPPER should “see” and report the
presence of all of the new SCSI HBAs and XP disk array devices.
4. Locate the I/O paths for the SCSI HBAs and disk array devices in the
MAPPER output, and record the paths for later use in SYSGEN or
IOCONFIG.
5. Exit the ODE system back to the ISL> prompt.
6. Start MPE/iX on the primary boot path.
7. Run either SYSGEN or IOCONFIG to perform I/O configuration of the
SCSI HBAs for the disk array devices and the disk array Ldevs.
8. For SYSGEN, after saving the I/O configuration, you must shut down
and restart the OS to put the new configuration into effect. For
IOCONFIG, the new configuration is immediately effective without any
shutdown and reboot.
HP StorageWorks Disk Array XP Operating System Configuration Guide: MPE/iX
9. Use the MPE/iX VOLUTIL utility to create volume sets and volumes
on the new disk array devices.
A sample I/O configuration procedure for disk array devices attached by
SCSI-FC Fabric Router is presented below. For brevity, this example
shows only relevant excerpts from the MAPPER listing:
1. Boot on the primary boot path.
Main Menu: Enter command or menu > bo pri
Interact with IPL (Y, N, or Cancel)?> y
Booting...
Boot IO Dependent Code (IODC) revision 1
SOFT Booted.
MMSAVE Version 2.8
DUMPAREA found, save main memory to disc
ISL loaded
ISL Revision A.00.43 Apr 12, 2000
ISL>
2. Invoke ODE.
ISL> ode
3. Run MAPPER. (A/N-Class systems use MAPPER2.)
all-guides.co
m
ODE> run mapper 2
STARTING EXECUTION OF MAPPER2
Processor Identification:
Hardware Model: 5CBH, Revision: 0
Software Model: 4H, Revision: 0
… …
I/O Configuration:
Type HW SW Revisions
Path Component Name ID Model Model Hdwr Firm
---------- ----------------------------------- ----- ----- ----- ----- -----
0 Astro BC Runway Port CH 582H BH 0 0
0/0 Elroy PCI Bridge DH 782H AH 0 0
0/0/0/0 Ethernet Controller 1011H 0019H 103CH 104FH 41H
… …
0/6 Elroy PCI Bridge DH 782H AH 0 0
0/6/2/0 Symbios SCSI Controller 1000H 000FH 103CH 12C0H 37H
0/6/2/0.0.0 HP OPEN-3 - - - - 0118
0/6/2/0.0.1 HP OPEN-3 - - - - 0118
0/6/2/0.0.2 HP OPEN-3 - - - - 0118
0/6/2/0.0.3 HP OPEN-3 - - - - 0118
… …
Resetting the Boot Device...
Done.
Exiting...
RUN COMPLETED.
ODE>
4. For the newly added disk array, the SCSI HBA is at I/O path 0/6/2/0,
and the disk array LUNs are at I/O paths 0/6/2/0.0.0, 0/6/2/0.0.1,
0/6/2/0.0.2, and so on.
5. Exit back to ISL> prompt.
ODE> exit
6. Start the OS on the primary boot path.
ISL> start norecovery group=config
7. Use IOCONFIG to configure the SCSI HBA and SCSI disk Ldevs.
CSYLE18:ioconfig
IOCONFIG A.00.00 (catalog A.00.00) (c) 1994 Hewlett-Packard Co. All Rights Reserved
ioconfig:lpath path=0/6
PATH: *0/6 LDEV:
ID: PAT_PCI_BC TYPE: BC
PMGR: PCI_ELROY_MGR PMGRPRI: 2
LMGR: MAXIOS: 0
ioconfig:lpath path=0/6/2
Warning: Path doesn't exist. (IOCONFIG 37)
ioconfig:
ioconfig:apath path=0/6/2; id=pci_device
ioconfig:apath path=0/6/2/0; id=a5159a
ioconfig:apath path=0/6/2/0.0; id=pseudo
ioconfig:adev ldev=300; path=0/6/2/0.0.0; id=hpdarray
Class(es) updated, so rerun asoctbl.pub.sys to recreate asociate.pub.sys.
BEGIN VOLUME MOUNTING ON LDEV 300 (AVR 9)
HP StorageWorks Disk Array XP Operating System Configuration Guide: MPE/iX
UNKNOWN VOLUME MOUNTED ON LDEV 300 (AVR 15)
ioconfig:adev ldev=301; path=0/6/2/0.0.1; id=hpdarray
Class(es) updated, so rerun asoctbl.pub.sys to recreate asociate.pub.sys.
BEGIN VOLUME MOUNTING ON LDEV 301 (AVR 9)
UNKNOWN VOLUME MOUNTED ON LDEV 301 (AVR 15)
ioconfig:adev ldev=302; path=0/6/2/0.0.2; id=hpdarray
Class(es) updated, so rerun asoctbl.pub.sys to recreate asociate.pub.sys.
BEGIN VOLUME MOUNTING ON LDEV 302 (AVR 9)
UNKNOWN VOLUME MOUNTED ON LDEV 302 (AVR 15)
ioconfig:exit
keeping to group CONFIG.SYS
Purge old configuration (yes/no)?Automatic yes
** configuration files successfully saved **
CSYLE18:
8. Run VOLUTIL to create volume sets and volumes as explained in the
next section.
Create volume sets and volumes
After I/O configuration has been completed, create volume sets and
member volumes on the disk array devices using the VOLUTIL utility in
the same way that you would do these tasks for any other MPE/iX disk.
Refer to the Volume Management manual (32650-90045) and to the
VOLUTIL section of the MPE/iX System Utilities Reference Manual
(32650-90908) for detailed information on volume creation and
management.
This section describes resolutions for various error conditions you may
encounter.
If you are unable to resolve an error condition, ask your HP support
representative for assistance. See “Calling the HP support center” on
page 44.
all-guides.co
m
HP StorageWorks Disk Array XP Operating System Configuration Guide: MPE/iX
Error conditions
Depending on your system configuration, you may be able to view error
messages as follows:
• In Remote Web Console (Status tab)
• In Command View Advanced Edition (“Alerts” panel).
• In Command View (Event History or Event Notification panels)
Error Condition
Recommended Action
The logical devices are not
recognized by the host.
Verify that the READY indicator lights on the disk array are ON.
Verify that fiber cables are correctly installed and firmly connected.
Verify that the target IDs are properly configured. The LUNs for each
TID must start at 0 and continue sequentially without skipping any
numbers.
Verify that the TIDs/WWNs on each bus are unique. Do not install
two devices with the same ID on the same bus.
Recheck the buses for new devices.
Verify that the disk array host mode is set correctly.
The host does not reboot
properly after hard shutdown.
If you power off the host without executing the shutdown process,
wait three minutes to allow the disk array’s internal timeout process to
purge queued commands. If the host restarts while the disk array is
processing queued commands, the host may not reboot successfully.
Volumes cannot be created.
Verify that the disk array logical devices are correctly formatted.
Verify with the appropriate utility (MAPPER or fcscan) that disk array
devices are recognized by the host system.
Verify all components of the SYSGEN I/O configuration pertaining to
the disk arrays.
The disk array performs a
self reboot because the disk
array was busy or it logged a
panic message.
Reboot the host.
The disk array responds “Not
Ready” or the disk array has
displayed “Not Ready” and
timed out.
Contact HP.
The host detects a parity
error.
Check the HBA and make sure it was installed properly.
Reboot the host.
The host hangs or devices are
declared down and the host
hangs.
Make sure there are no duplicate disk array TIDs and that disk array
TIDs do not conflict with any host TIDs.
Error Condition
Recommended Action
HP StorageWorks Disk Array XP Operating System Configuration Guide: MPE/iX
Calling the HP support center
If you are unable to resolve an error condition, contact the HP support
center for assistance.
Contact Information
In North America, call technical support at 1-800-633-3600, available 24
hours a day, 7 days a week.
Outside North America, call technical support at the location nearest you.
The HP web site lists telephone numbers for worldwide technical support
at: http://www.hp.com/support. From this web site, select your country.
Before you call
Be sure to have the following information available:
• Technical support registration number (if applicable)
• Product serial numbers
• Product model names and numbers
• Applicable error messages
• Operating system type and revision level
• Detailed, specific questions
Disk array device emulations
45
A
Disk array device emulations
This appendix provides information about supported emulations and device
type specifications. Some parameters may not be relevant to your array.
Consult your HP representative for information about supported
configurations for your system.
HP StorageWorks Disk Array XP Operating System Configuration Guide: MPE/iX
Supported emulations
MPE/iX systems support ONLY the OPEN-x emulations. LUSE and CVS
are not supported.
XP Model
OPEN
Emulation
Type
OPEN
Emulation
Supported LUSE
CVS
LUSE & CVS
OPEN-3
Yes
XP128
OPEN-8
Yes
XP1024
OPEN-9
Yes
XP10000
OPEN-K
XP12000
OPEN-L
Yes
OPEN-M
OPEN-V
Yes
all-guides.co
m
Disk array device emulations
47
Device type specifications
*Capacity = (512 x number of blocks) ÷ 10242
Device Type
(Note 1)
Category
(Note 2)
Blocks
(512 bytes )
Sector
Size
(bytes)
# of
Cylinders
Heads
Sectors
per
Track
Capacity MB*
(Note 3)
OPEN-3
SCSI disk
4806720
512
3338
15
96
2347
OPEN-8
SCSI disk
14351040
512
9966
15
96
7007
OPEN-9
SCSI disk
14423040
512
10016
15
96
7042
OPEN-E
SCSI disk
28452960
512
19759
15
96
13893
OPEN-L
SCSI disk
71192160
512
49439
15
96
34761
OPEN-V
SCSI disk
max=125827200
512
Note 5
15
128
Note 6
LUSE
OPEN-3*n
SCSI disk
4806720*n
512
3338*n
15
96
2347*n
OPEN-8*n
SCSI disk
14351040*n
512
9966*n
15
96
7007*n
OPEN-9*n
SCSI disk
14423040*n
512
10016*n
15
96
7042*n
OPEN-E*n
SCSI disk
28452960*n
512
19759*n
15
96
13893*n
OPEN-L*n
SCSI disk
71192160*n
512
49439*n
15
96
34761*n
OPEN-V*n
SCSI disk
max=125827200
Note 4
512
Note 5
15
128
Note 6
CVS
OPEN-3 CVS
SCSI disk
Note 4
512
Note 5
15
96
Note 6
OPEN-8 CVS
SCSI disk
Note 4
512
Note 5
15
96
Note 6
OPEN-9 CVS
SCSI disk
Note 4
512
Note 5
15
96
Note 6
OPEN-E CVS
SCSI disk
Note 4
512
Note 5
15
96
Note 6
CVS LUSE
OPEN-3*n CVS
SCSI disk
Note 4
512
Note 5
15
96
Note 6
OPEN-8*n CVS
SCSI disk
Note 4
512
Note 5
15
96
Note 6
OPEN-9*n CVS
SCSI disk
Note 4
512
Note 5
15
96
Note 6
OPEN-E*n CVS
SCSI disk
Note 4
512
Note 5
15
96
Note 6
OPEN-V*n
SCSI disk
Note 4
512
Note 5
15
128
Note 6
HP StorageWorks Disk Array XP Operating System Configuration Guide: MPE/iX
Note 1:
The availability of a disk type depends on the disk array.
Note 2:
The devices are defined to the host as SCSI disk devices, even though the
interface is Fibre Channel.
Note 3:
The device capacity can sometimes be changed by the BIOS or host adapter
board. This may make actual capacity different from that listed in the table.
Note 4:
The number of blocks for a CVS volume is calculated as follows:
# of blocks = (# of cylinders) × (# of heads) × (# of sectors per track)
Example 1: For an OPEN-3 CVS volume with capacity = 37 MB:
# of blocks = (53 cylinders–see Note 5) × (15 heads) × (96 sectors per
track) = 76320
Example 2: For an OPEN-V CVS volume with capacity = 49 MB:
# of blocks = (53 cylinders–see Note 5) × (15 heads) × (128 sectors per
track) = 101760
Note 5:
The number of cylinders for a CVS volume is calculated as follows (↑…↑
means that the value should be rounded up to the next integer):
OPEN-3/8/9/E: The number of cylinders for a CVS volume =
# of cylinders = ↑ (capacity (MB) specified by user) × 1024/720 ↑
Example: For an OPEN-3 CVS volume with capacity = 37 MB:
# of cylinders = ↑37 × 1024/720↑ = ↑52.62↑ (rounded up to next integer) =
53 cylinders
OPEN-V: The number of cylinders for a CVS volume =
# of cylinders = ↑ (capacity (MB) specified by user) × 16/15 ↑
Example: For an OPEN-V CVS volume with capacity = 49 MB:
# of cylinders = ↑49 × 16/15↑ = ↑52.26↑ (rounded up to next integer) = 53
cylinders
OPEN-3/8/9/E: The number of cylinders for a CVS LUSE volume =
# of cylinders = ↑ (capacity (MB) specified by user) × 1024/720 ↑ × n
Disk array device emulations
49
Example: For a CVS LUSE volume with capacity = 37 MB and n = 4
# of cylinders = ↑37 × 1024/720↑ × 4 = ↑52.62↑× 4 = 53 × 4 = 212
OPEN-V: The number of cylinders for a CVS LUSE volume =
# of cylinders = ↑ (capacity (MB) specified by user) × 16/15 ↑ × n
Example: For an OPEN-V CVS LUSE volume with capacity = 49 MB and
n = 4
# of cylinders = ↑49 × 16/15↑ × 4 = ↑52.26↑× 4 = 53 × 4 = 212
Note 6:
The capacity of an OPEN-3/8/9/E CVS volume is specified in MB, not
number of cylinders. The capacity of an OPEN-V CVS volume can be
specified in MB or number of cylinders. You set the volume size using the
Remote Web Console, Command View, or Command View Advanced
Edition software.
Booting from the array
51
B
Booting from the array
In order to use a native Fibre Channel-connected disk array as MPE/iX
Ldev 1 (the boot disk) to load, boot, and run the OS software, you must
know the primary I/O boot path leading to the desired LUN in the XP disk
array. The primary boot path must be set into PDC memory so that the
processor will be able to perform I/O to the disk device during system boot
operations.
You can use one of three methods to determine the primary boot path for
your disk array LUN, depending on the particular situation. These methods
are summarized at the start of this appendix and are explained in detail on
the page referred to in the summary.
all-guides.co
m
HP StorageWorks Disk Array XP Operating System Configuration Guide: MPE/iX
1. Existing MPE/iX 7.5 boot disk is available (page 54):
If the system already has an MPE/iX Release 7.5 OS installed on an
existing disk device (internal or external SCSI disk), use the following
procedure.
• Boot and run the OS from the existing Ldev 1 boot disk.
• Use the fcscan –h utility program for native Fibre Channel I/O path
mapping. This will give you the BOOT MENU PATH for all of the
native Fibre Channel attached disk array devices.
• Select the desired disk array LUN to be your new Ldev 1.
• Use the BOOT MENU PATH from fcscan as the primary boot path.
2. No existing MPE/iX boot disk available and disk array is direct Fibre
Channel connected (page 57):
If the system does not already have an MPE/iX Release 7.5 OS
installed, and the disk array you want to use for MPE/iX Ldev 1 is
native Fibre Channel and directly cabled to the host HP e3000 system
(no Fibre Channel switch), then use the following procedure.
• Use the MAPPER2 I/O mapping utility of the ODE (Offline
Diagnostic Environment) to display the boot menu I/O paths for all
of the LUNs of that disk array. MAPPER2 will correctly detect and
report the paths for a direct-Fibre-Channel-connected disk array.
• Boot the system from the SLT (System Load Tape) on the alternate
boot path.
• Run ODE>MAPPER2.
• Select the desired disk array LUN to be your new Ldev 1, and use the
I/O path reported by MAPPER2 to be the primary boot path.
• Install the OS onto the new Ldev 1.
3. No existing MPE/iX boot disk available and disk array is Fibre Channel
switch connected (page 59):
If the system does not already have an MPE/iX Release 7.5 OS
installed and the disk array you want to use for MPE/iX Ldev 1 is
Booting from the array
53
SAN-connected (through a Fibre Channel switch) to the host HP
e3000 system, then use the following procedure.
• You CANNOT use the MAPPER2 facility to determine the I/O paths
for the disk array. MAPPER2 will not be able to recognize and report
the LUNs of the disk array on the Fibre Channel switch.
• You must use web browser access via LAN to the Fibre Channel
switch to determine the I/O path to use for the primary boot path.
The remainder of this appendix gives more detailed procedures, illustrated
with actual examples, for these three methods of determining the primary
boot path and loading the OS software onto a native Fibre Channel
connected disk array.
HP StorageWorks Disk Array XP Operating System Configuration Guide: MPE/iX
Existing MPE/iX 7.5 boot disk is available
If an existing MPE/iX boot disk is available, simply boot and start the
system from the existing boot disk in normal fashion.
When the system is up, run the fcscan –h command to find and display the
I/O paths for the newly connected disk array devices.
NOTE: Before you can run fcscan to find the paths for the disk array
devices, you must configure the native Fibre Channel HBAs used to
connect the disk arrays to the MPE/iX I/O system configuration. The
fcscan command depends on finding the Fibre Channel HBAs in the
existing system configuration in order to perform its search for attached
disk array devices.
Follow this procedure if you have an existing boot disk:
1. Boot and start the existing system normally from the existing boot disk.
Main Menu: Enter command or menu > bo pri
Interact with IPL (Y, N, or Cancel)?> y
Booting...
Boot IO Dependent Code (IODC) revision 1
SOFT Booted.
MMSAVE Version 2.8
DUMPAREA found, save main memory to disc
ISL loaded
ISL Revision A.00.43 Apr 12, 2000
ISL> start norecovery group=config
MPE/iX launch facility
Scanning PCI BUS 0 +**.++..........................
Scanning PCI BUS 10 +...............................
Scanning PCI BUS 20 +...............................
Scanning PCI BUS 30 +.*.............................
Initialize_genesis - Ver bld1: <>
THU, JUL 29, 2004, 10:39:49 AM (y/n)?
Initialize_genesis = Ready to configure I/O
[CDM] 03 07 02 12
Initialize genesis completed.
Create Console Messages kso completed.
… …
Booting from the array
55
2. Run IOCONFIG to add the new Fibre Channel HBAs to the existing
system’s I/O configuration (or run SYSGEN if you prefer, but that will
require a system reboot after the configuration has been modified). You
should have recorded the I/O paths for the HBAs when the HBAs were
installed. In this example, the A6795A Fibre Channel HBA was
installed at I/O path 0/6/0/0.
CSYLE18:ioconfig
IOCONFIG A.00.00 (catalog A.00.00) (c) 1994 Hewlett-Packard Co. All Rights Reserved
ioconfig:ap path=0/6/0; id=pci_device
ioconfig:ap path=0/6/0/0; id=a6795a
td: claimed Tachyon XL2 Fibre Channel Mass Storage card at 0/6/0/0
Scanning for fibre channel devices at 0/6/0/0. This may take a while...
ioconfig: ex
keeping to group CONFIG.SYS
Purge old configuration (yes/no)?Automatic yes
** configuration files successfully saved **
CSYLE18:
3. Run the fcscan –h utility to obtain the I/O paths for the disk array
N-ports and LUNs.
CSYLE18:fcscan -h
FCSCAN Version 1.1
Scanning for Fibre Channel devices.
This could take upto few minutes. Please wait ...
FCSCAN has found the following Fibre Channel I/O Adapter Cards and Devices
on this system.
SYSGEN PATH DESCRIPTION BOOT MENU PATH
============= ============= ================
0/6/0/0 Fibre Channel Adapter
0/6/0/0.102 Fibre Channel N-Port
0/6/0/0.102.0 HP OPEN-3 disk 0/6/0/0.8.0.102.0.0.0
0/6/0/0.102.1 HP OPEN-3 disk 0/6/0/0.8.0.102.0.0.1
0/6/0/0.102.2 HP OPEN-3 disk 0/6/0/0.8.0.102.0.0.2
0/6/0/0.102.3 HP OPEN-3 disk 0/6/0/0.8.0.102.0.0.3
… …
CSYLE18:
4. Choose the disk array LUN that you will use as the new MPE/iX Ldev
1 and note the BOOT MENU PATH I/O path for that disk in the fcscan
output listing. That path will become the system’s primary boot path.
For this example, LUN 2 on the disk array was used at BOOT MENU
PATH 0/6/0/0.8.0.102.0.0.2
HP StorageWorks Disk Array XP Operating System Configuration Guide: MPE/iX
5. Shut down the running system and reset (or TC) the computer.
CSYLE18: shutdown system
SESSION aborted by system management. (CIERR 6027)
CPU=2. Connect=60. TUE, AUG 24, 2004, 3:53 PM.
15:53/#S2/46/LOGOFF ON LDEV #20.
Spoolers notified of a shutdown. (Shut 16)
15:53/47/The Spooling system has been shutdown.
Shutdown of system processes begins. (Shut 4)
Shutdown of system managers begins. (Shut 5)
Shutdown of operating system complete. (Shut 6)
6. Set the system’s primary boot path to the BOOT MENU PATH you
noted in step 4 above.
Main Menu: Enter command or menu > pa pri 0/6/0/0.8.0.102.0.0.2
Primary boot path: 0/6/0/0.8.0.102.0.0.2
0/6/0/0.8.0.66.0.0.2(hex)
7. You can now install the OS from the SLT (System Load Tape) on the
alternate boot path onto the disk array device on the primary boot path.
Primary boot path: 0/6/0/0.8.0.102.0.0.2
Alternate boot path: 0/0/2/0.6
Console path: 0/0/4/0.0
Keyboard path: 0/0/4/0.0
Main Menu: Enter command or menu > bo alt
Interact with IPL (Y, N, or Cancel)?> y
Booting...
Boot IO Dependent Code (IODC) revision 1
SOFT Booted.
TAPEIPL Version 1.0
ISL loaded
ISL Revision A.00.43 Apr 12, 2000
ISL> install
……
8. When you are finished loading the OS software, return to the main body
of this document at “Configure the disk array devices in MPE/iX” (page
31).
all-guides.co
m
Booting from the array
57
No existing MPE/iX boot disk available and disk
array is direct Fibre Channel connected
If you have no boot disk available and the disk array is direct Fibre Channel
connected, you can use the MAPPER2 utility while the system is booted
from the SLT tape on the alternate boot path. MAPPER2 will locate and
display the boot menu I/O paths for the directly Fibre Channel attached disk
arrays. You choose the desired disk array LUN from the MAPPER2 output
to become the new MPE/ix Ldev 1 boot disk, and then use the MAPPER2
I/O path to set the system’s primary boot path for loading the OS.
Follow this procedure and example to use MAPPER2 to set the boot
path:
For brevity, only an excerpt of the MAPPER2 output is shown.
1. Boot the system from the SLT tape on the alternate boot path.
Main Menu: Enter command or menu > bo alt
Interact with IPL (Y, N, or Cancel)?> y
Booting...
Boot IO Dependent Code (IODC) revision 1
SOFT Booted.
TAPEIPL Version 1.0
ISL loaded
ISL Revision A.00.43 Apr 12, 2000
ISL>
2. Invoke the ODE environment and run the MAPPER2 utility.
ISL> ode
… …
ODE> run mapper2
3. Choose the desired disk array LUN as the new boot disk and record its
I/O path from MAPPER2. In the following example, LUN 2 of the disk
array is used at path 0/6/0/0.8.0.102.0.0.2.
HP StorageWorks Disk Array XP Operating System Configuration Guide: MPE/iX
STARTING EXECUTION OF MAPPER2
Processor Identification:
Hardware Model: 5CBH, Revision: 0
Software Model: 4H, Revision: 0
… …
I/O Configuration:
Type HW SW Revisions
Path Component Name ID Model Model Hdwr Firm
---------- ----------------------------------- ----- ----- ----- ----- -----
0 Astro BC Runway Port CH 582H BH 0 0
0/0 Elroy PCI Bridge DH 782H AH 0 0
0/0/0/0 Ethernet Controller 1011H 0019H 103CH 104FH 41H
… …
0/6/0/0 HP 6795A 2G/1G Fibre Chan. Adapter 103CH 1029H 103CH 128CH 0BH
0/6/0/0.8.0.102.0.0.0
HP OPEN-3 - - - - 0118
0/6/0/0.8.0.102.0.0.1
HP OPEN-3 - - - - 0118
0/6/0/0.8.0.102.0.0.2
HP OPEN-3 - - - - 0118
0/6/0/0.8.0.102.0.0.3
HP OPEN-3 - - - - 0118
4. Exit the ODE environment back to the ISL> prompt, and set the desired
primary boot path.
ODE> exit
ISL> primpath 0/6/0/0.8.0.102.0.0.2
5. Now INSTALL the OS software from the SLT on the alternate boot path
to the selected disk array device on the primary boot path.
ISL> install
… …
6. When finished loading the OS software, return to the main body of this
document at “Configure the disk array devices in MPE/iX” (page 31).
Booting from the array
59
No existing MPE/iX boot disk available and disk
array is Fibre Channel switch connected
If you have no boot disk and the array is connected to a Fibre Channel
switch, the MAPPER2 utility CANNOT be used to determine the I/O paths
for the disk array devices. Instead, you need to derive the primary boot path
information from the known I/O path of the A6795A Fibre Channel HBA
(recorded at hardware installation time) and the known configuration of
LUNs within the disk array (established earlier with Command View XP or
LUN Configuration Manager). Additional path information must be
obtained by LAN connection of a suitable web browser to the Fibre
Channel switch.
Primary boot path format for Fibre Channel devices
In order to form the desired primary I/O boot path for the disk array to be
used as Ldev 1, you will be combining three parts of the I/O path to make
the whole I/O path in the format required by processor PDC for boot paths:
• The part of the I/O path that belongs to the A6795A Fibre Channel
HBA, plus
• The part of the I/O path that belongs to the disk array’s Fibre Channel
interface (the N-Port), plus
• The part of the I/O path that gives the SCSI target ID and LUN
information for a LUN within the disk array.
PDC on A-Class and N-Class systems requires the following format for
combining these I/O path parts:
|-- HBA I/O Path Part --|--- FC N-Port I/O Path Part---|- SCSI LUN I/O Path Part-|
BC / BC / BC / Card . Domain . Area . Port . Bus# . Target ID . LUN
0 / 6 / 0 / 0 . 1 . 20 . 44 . 1 . 3 . 0
You should already know the HBA I/O path, recorded when the HBA
hardware was installed and also the SCSI LUN I/O path. The following
section explains how to use a web browser to determine the FC N-Port I/O
path needed to complete the whole primary boot path.
HP StorageWorks Disk Array XP Operating System Configuration Guide: MPE/iX
Determining the FC N-Port I/O path
Using a web browser, navigate to the address of your Fibre Channel switch,
where you will see a display similar to the one below. Details may differ
depending on switch model and firmware level. Look for the “Name
Server” control button. In the example below, it is the third button down
from the top on the left side of the display.
Click on the Name Server button to access the Name Server display, and
the switch will present a display a name server table similar to the one that
follows.
Booting from the array
61
You should already know the port number of the plug-in port on the Fibre
Channel switch where you have connected the disk array. If you need to,
trace the Fibre Channel cable from the disk array to the switch and
determine the port to which the array is connected. In the example figure
above, the disk array is connected to pors 5 of the switch. You will notice
the disk model information in the “Symbolic Name” portion of the Name
Server display, at the right on the line for Port # 5.
The Port ID column of the display has the information needed to form the
FC N-Port part of the I/O path. The Port ID is a 6-character hexadecimal
digit (3 bytes) that decomposes into the three portions (Domain.Area.Port)
of the FC N-Port part of the I/O path. Since PDC boot paths are set as
decimal numbers, these three portions of FC N-Port value have to be
converted from hex to decimal before you can use them to set the primary
boot path.
Example for Port #5, Port ID 011532
In the Name Server display above, the disk array on Port 5 has Port ID =
011532, hexadecimal. To convert this to the FC N-Port format required by
PDC, break apart the 6 digit hex number into its 3 hex bytes, and convert
all-guides.co
m
HP StorageWorks Disk Array XP Operating System Configuration Guide: MPE/iX
each hex byte to its decimal equivalent. The resulting three decimal
numbers become the FC N-Port (Domain.Area.Port) portion of the primary
boot path:
• 011532 hex � 01 15 32
• 01 hex � 01 decimal
• 15 hex � 21 decimal
• 32 hex � 50 decimal
so the FC N-Port portion of the I/O path is 1.21.50.
Composing the entire primary I/O boot path
You can now form the entire primary I/O boot path for PDC by combining:
• the HBA part of the path, 0/6/0/0
• the FC N-Port part of the path, 1.21.50
• your selected SCSI LUN within the disk array, for this example: 0.0.2
(bus.target.lun)
to get the complete primary I/O boot path 0/6/0/0.1.21.50.0.0.2.
Now set the system’s primary boot path to that value, and then install the
OS from the SLT tape.
When you are finished loading the OS, return to the main body of this
manual at the “Configure the disk array devices in MPE/iX” (page 31).
Arbitrated loop physical address.
array group
A group of 4 or 8 physical hard disk drives (HDDs) installed in an XP disk
array and assigned a common RAID level. RAID1 array groups are made
up of 4 HDDs (2D+2D). A RAID1 group is two 4 HDD array groups
concatenated together (4D+4D). RAID5 array groups are made up of 4 or 8
HDDs, depending on whether they are RAID5 3D+1P or RAID5 7D+1P,
respectively. All RAID6 array groups are made up of 8 HDDs (6D+2P).
BC
HP StorageWorks Business Copy XP. BC lets you maintain up to nine local
copies of logical volumes on the disk array.
CA
HP StorageWorks Continuous Access XP. CA lets you create and maintain
duplicate copies of local logical volumes on a remote disk array.
Command View
(CVXP)
HP StorageWorks Command View XP, a software product for managing XP
arrays. Command View runs on a Windows-based management workstation.
Command View XP
Advanced Edition
(CVXP AE)
HP StorageWorks Command View XP Advanced Edition, installs on the
user-provided Device Manager server and provides a browser-based
platform from which you can manage the XP family of disk arrays—even
globally distributed arrays.
command device
A volume on the disk array that accepts Continuous Access or Business Copy
control operations which are then executed by the disk array.
CU
Control Unit. Contains LDEVs and is approximately equivalent to SCSI
Target ID.
HP StorageWorks Disk Array XP Operating System Configuration Guide: MPE/iX
CVS
Custom volume size. CVS devices (OPEN-x CVS) are custom volumes
configured using array management software to be smaller than normal
fixed-size OPEN system volumes. Synonymous with volume size
customization (VSC).
DKC
(disk controller unit)
The array cabinet that houses the channel adapters and service processor
(SVP).
DKU
(disk cabinet unit)
The array cabinets that house the disk array physical disks.
emulation modes
The logical devices (LDEVs) associated with each RAID group are assigned
an emulation mode that makes them operate like OPEN system disk drives.
The emulation mode determines the size of an LDEV:
OPEN-3: 2.46 GB
OPEN-8: 7.38 GB
OPEN-9: 7.42 GB
OPEN-E: 13.56 GB
OPEN-L: 36 GB
OPEN-V: User-defined custom size
failover
Disconnecting a failed unit or path and replacing it with an alternative unit
or path in order to continue functioning.
FC
Fibre Channel.
FC-AL
Fibre Channel arbitrated loop.
FCP
Fibre Channel Protocol.
GB
Gigabytes
HBA
Host bus adapter.
host mode
Each port can be configured for a particular host type. These modes are
represented as two-digit hexadecimal numbers. For example, host mode 08
represents an HP-UX host.
As it relates to MPE/iX, Ldev refers to an MPE logical device
synonymous with an MPE volume member, MPE device or LUN
created under the control of MPE/iX's SYSGEN utility program.
LDEV
Logical device. An LDEV is created when a RAID group is carved into pieces
according to the selected host emulation mode (that is, OPEN-3, OPEN-8,
OPEN-L). The number of resulting LDEVs depends on the selected
emulation mode. The term LDEV is often used synonymously with the term
volume.
LUN
Logical unit number. A LUN results from mapping a SCSI logical unit
number, port ID, and LDEV ID to a RAID group. The size of the LUN is
determined by the emulation mode of the LDEV and the number of LDEVs
associated with the LUN. For example, a LUN associated with two OPEN-
3 LDEVs has a size of 4,693 MB.
LUSE
A LUN is normally associated with only a single LDEV. The LUSE feature
allows a LUN to be associated with 1 to 36 LDEVs. Essentially, LUSE makes
it possible for applications to access a single large pool of storage. The LUSE
feature is available when the HP StorageWorks LUN Configuration Manager
product is installed.
OFC
Open Fibre Control.
OPEN-x
A general term describing any one of the supported OPEN emulation
modes (for example, OPEN-L).
OS
Operating system.
PA
Physical address.
path
“Path” and “LUN” are synonymous. Paths are created by associating a port,
a target, and a LUN ID with one or more LDEVs.
port
A physical connection that allows data to pass between a host and the disk
array. The number of ports on an XP disk array depends on the number of
supported I/O slots and the number of ports available per I/O adapter. The
XP family of disk arrays supports Fibre Channel (FC) ports as well as other
port types. Ports are named by port group and port letter, such as CL1-A.
CL1 is the group, and A is the port letter.
HP StorageWorks Disk Array XP Operating System Configuration Guide: MPE/iX
RAID
Redundant array of independent disks.
remote console PC
The PC running HP StorageWorks Remote Control XP.
Remote Control (RC)
HP StorageWorks Remote Control XP. A software product used for
managing XP arrays.
Remote Web Console
(RWC)
HP StorageWorks XP Remote Web Console. A browser-based program
installed on the SVP that allows you to configure and manage the disk array.
R-SIM
Remote service information message.
SCSI
Small computer system interface.
SIM
Service information message.
SNMP
Simple Network Management Protocol.
SVP
Service processor, which is the PC built into the disk controller. The SVP
provides a direct interface into the disk array. SVP use is reserved for HP
support representatives only.
TB
Terabyte.
TID
Target ID.
Volume
On the XP array, a volume is a uniquely identified virtual storage device
composed of a control unit (CU) component and a logical device (LDEV)
component separated by a colon. For example 00:00 and 01:00 are two
uniquely identified volumes; one is identified as CU = 00 and LDEV = 00,
and the other as CU = 01 and LDEV = 00; they are two unique separate virtual
storage devices within the XP array.
VSC
Volume size customization. Synonymous with CVS.
WWN
World Wide Name. A unique identifier assigned to a Fibre Channel device.
all-guides.co
m
arbitrated-loop physical address 22
authorized resellers 7
Auto LUN XP 15
Auto Path XP 15
B
boot(ing)
after hard shutdown 42
Fibre Channel, primary boot path 59
from the array 51
boot disk available 54
boot disk not available, direct Fibre
Channel 57
boot disk not available, Fibre Channel
switch 59
Business Copy XP 15, 17
C
Cache LUN XP 15
Cluster Extension XP 15
clustering 25
command device(s)
designate at least one LDEV as a 17
RAID Manager 17
Command View 14, 17, 19, 22, 28
Command View XP Advanced Edition 14, 17,
19, 22, 28, 29
configuration
device 31
Fibre Channel 32
Fibre Channel ports 22
HBAs 24
host 24
host mode, setting 19
port 22
System Option Mode 21
Continuous Access Extension XP 15
Continuous Access XP 15, 17
D
Data Exchange XP 15
device(s)
configuring 31
logical, not recognized 42
supported 16
type specifications 47
disk array(s)
connecting 27
features 14
Fibre Channel configuration 32
installation overview 18
HP StorageWorks Disk Array XP Operating System Configuration Guide: MPE/iX
Not Ready error message 43
operating system versions 14
requirements 14
SCSI-FC Fabric Router 35
self reboots 43
server support 14
storage capacity 14
supported 5
documentation
related 6
E
emulations 46
error conditions 42
F
fabric environment
port addresses 22
zoning 25
fabric router
SCSI-FC, attachment 35
failover 16
Fibre Channel
interface 15
native 51
native, disk array attachment 32
N-Port I/O path 60
ports, configuring 22
primary boot path 59
G
glossary 63
H
HBA(s)
configuring 24
supported 24
host
configuration 24
doesn’t reboot properly after hard
shutdown 42
hangs up 43
installation 24
host bus adapters, see "HBAs"
host mode, setting 19
HP
service representative tasks 19
technical support 44
I
installation
connecting disk array 27
host 24
HP service representative tasks 19
operating system 30
overview 18
interface, Fibre Channel 15
L
LDEV(s)
designate at least one as a command
device 17
LUN Configuration and Security Manager
XP 15, 19, 28, 29
LUN(s)
creating 28
mapping 28
LUN(s), security 25
M
multi-cluster environment 25
O
operating system(s)
installing 30
supported versions 14
parity error 43
path(s)
defining 28
Fibre Channel N-Port I/O 60
Fibre Channel primary boot 59
storage capacity 29
Performance Advisor XP 15
port(s)
address 22
Fibre Channel 22
host mode, setting 19
R
RAID Manager command devices 17
RAID Manager XP 15
Remote Web Console 14, 17, 19, 22, 28
resellers, authorized 7
Resource Manager XP 15
S
SCSI disk, Fibre Channel interface and term
"SCSI disk" 15
SCSI-FC Fabric Router 15, 35
security, LUN 25
server, support 14
SNMP configuration 16
software, optional 15
storage capacity 14
StorageWorks, supported arrays 5
system administrator, required knowledge 5
System Option Mode, setting 21
T
technical support 7, 44
troubleshooting 41
error conditions 42
technical support 44
V
volume(s), cannot be created 42
W
warranty 10
web site
HP storage 8
X
XP family
optional software 15
storage capacity 14
Z
zoning, fabric 25