HP 5920 & 5900 Switch Series

FC and FCoE Command Reference Part number: 5998-6629 Software version: Release 2416 Document version: 6W100-20150130

Legal and notice information

© Copyright 2015 Hewlett-Packard Development Company, L.P. No part of this documentation may be reproduced or transmitted in any form or by any means without prior written consent of Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. HEWLETT-PACKARD COMPANY MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS MATERIAL, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Hewlett-Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.

FC and FCoE commands ············································································································································· 1

FCoE mode commands ····················································································································································· 1 display fcoe-mode ···················································································································································· 1 fcoe-mode ·································································································································································· 1 FC interface commands ···················································································································································· 3 bandwidth ································································································································································· 3 default ········································································································································································ 3 description ································································································································································· 4 display interface fc ··················································································································································· 5 fc mode (FC interface view) ································································································································· 12 fcb2bcredit ····························································································································································· 13 fill-word ··································································································································································· 13 interface fc ····························································································································································· 14 port-type ·································································································································································· 15 reset counters interface ········································································································································· 15 shutdown ································································································································································ 16 speed ······································································································································································ 16 VFC interface commands ·············································································································································· 17 bandwidth ······························································································································································ 17 bind interface ························································································································································· 18 default ····································································································································································· 20 description ······························································································································································ 21 display interface vfc ·············································································································································· 21 fc mode (VFC interface view) ······························································································································· 25 interface vfc ···························································································································································· 25 reset counters interface ········································································································································· 26 shutdown ································································································································································ 27 FC link aggregation commands ··································································································································· 27 bandwidth ······························································································································································ 27 default ····································································································································································· 28 description ······························································································································································ 28 display interface san-aggregation ······················································································································· 29 display san-aggregation ······································································································································· 32 fc mode (FC aggregate interface view) ·············································································································· 35 interface san-aggregation····································································································································· 36 reset counters interface ········································································································································· 36 san-aggregation group ········································································································································· 37 san-aggregation load-sharing mode local-first ··································································································· 38 shutdown ································································································································································ 38 FCoE commands ···························································································································································· 39 display fcoe ···························································································································································· 39 fcoe enable ···························································································································································· 40 fcoe fcf-priority ······················································································································································· 41 fcoe fcmap ····························································································································································· 42 fcoe fka-adv-period ··············································································································································· 42 fcoe global fcf-priority ··········································································································································· 44 VSAN commands ··························································································································································· 45 display vsan port-member ···································································································································· 45 port ·········································································································································································· 46

port access vsan ···················································································································································· 46

port trunk mode ····················································································································································· 47 port trunk vsan ······················································································································································· 48 vsan ········································································································································································· 49 Fabric building commands ············································································································································ 49 allowed-domain-id ················································································································································· 49 display fc domain ·················································································································································· 50 display fc domain-list ············································································································································ 52 display fc ess ························································································································································· 53 display fc login ······················································································································································ 54 display fc name-service database ······················································································································· 55 display fc scr-table ················································································································································· 58 display fc switch-wwn ··········································································································································· 59 display fc timer ······················································································································································ 59 domain auto-reconfigure enable ·························································································································· 60 domain configure enable ····································································································································· 61 domain restart ························································································································································ 61 domain-id ······························································································································································· 62 fabric-name ···························································································································································· 63 fc domain rcf-reject ················································································································································ 64 fc name-service auto-discovery ···························································································································· 64 fc timer distributed-services ··································································································································· 65 fc timer error-detect ··············································································································································· 66 fc timer resource-allocation··································································································································· 67 fc wwn default-fc4-type ········································································································································· 67 priority ···································································································································································· 68 rscn aggregation enable ······································································································································ 69 rscn aggregation timer ·········································································································································· 70 snmp-agent trap enable fc-fabric ························································································································· 71 snmp-agent trap enable fc-name-service ············································································································· 71 timer distributed-services ······································································································································· 72 timer error-detect···················································································································································· 73 timer resource-allocation ······································································································································· 74 wwn area-port-id ··················································································································································· 74 FC routing and forwarding commands························································································································ 75 display fc exchange ·············································································································································· 75 display fc fib ·························································································································································· 77 display fc routing-table ········································································································································· 79 display fspf graceful-restart ·································································································································· 82 display fspf lsdb ····················································································································································· 83 display fspf neighbor ············································································································································ 84 display fspf statistics ·············································································································································· 85 fc route-static ·························································································································································· 87 fspf cost··································································································································································· 88 fspf dead-interval ··················································································································································· 89 fspf enable ····························································································································································· 90 fspf graceful-restart ················································································································································ 90 fspf graceful-restart helper ···································································································································· 91 fspf graceful-restart interval ·································································································································· 91 fspf hello-interval ···················································································································································· 92 fspf min-ls-arrival ···················································································································································· 93 fspf min-ls-interval ·················································································································································· 94 fspf retransmit-interval ··········································································································································· 94 fspf silent ································································································································································· 95

fspf spf-hold-time ···················································································································································· 96

reset fspf counters ·················································································································································· 96 FC zone commands ······················································································································································· 97 delete zone database all ······································································································································ 97 display zone ·························································································································································· 97 display zone member ··········································································································································· 99 display zone statistics ········································································································································· 101 display zone status ·············································································································································· 102 display zone-alias················································································································································ 103 display zoneset ···················································································································································· 104 display zoneset active ········································································································································· 106 member (zone view) ············································································································································ 108 member (zone alias view) ·································································································································· 109 member (zone set view) ······································································································································ 111 pairwise-zoning enable ······································································································································ 111 reset zone statistics ·············································································································································· 112 snmp-agent trap enable fc-zone ························································································································· 113 zone clone ···························································································································································· 114 zone default-zone permit ···································································································································· 114 zone hard-zoning enable ··································································································································· 115 zone merge-control restrict ································································································································· 116 zone mode enhanced ········································································································································· 117 zone name ··························································································································································· 118 zone rename ························································································································································ 118 zone-alias clone ··················································································································································· 119 zone-alias name ·················································································································································· 120 zone-alias rename ··············································································································································· 120 zoneset activate ··················································································································································· 121 zoneset clone ······················································································································································· 122 zoneset distribute ················································································································································· 123 zoneset distribute full ··········································································································································· 123 zoneset name ······················································································································································· 124 zoneset rename ··················································································································································· 125 NPV commands ···························································································································································· 125 display fc nport ···················································································································································· 125 display npv login ················································································································································· 127 display npv status ················································································································································ 128 display npv traffic-map ······································································································································· 130 npv load-balance disruptive ······························································································································· 131 npv traffic-map ····················································································································································· 131 FIP snooping commands ·············································································································································· 132 display fip-snooping enode ································································································································ 132 display fip-snooping fcf ······································································································································· 133 display fip-snooping flushing-rules ····················································································································· 133 display fip-snooping rules ··································································································································· 134 display fip-snooping sessions ····························································································································· 135 fip-snooping enable ············································································································································ 136 fip-snooping fc-map ············································································································································· 137 fip-snooping port-mode ······································································································································· 137 FCS commands ····························································································································································· 138 fcs discovery start ················································································································································ 138 fcs discovery stop ················································································································································ 139 display fcs discovery status ································································································································ 139 display fcs database ··········································································································································· 140

display fcs ie ························································································································································ 142

display fcs port ···················································································································································· 144 FDMI commands ·························································································································································· 147 display fdmi database ········································································································································ 147 FC ping commands ······················································································································································ 151 fcping ···································································································································································· 151 FC tracert commands ··················································································································································· 152 fctracert ································································································································································· 152 Support and other resources ·································································································································· 155 Contacting HP ······························································································································································ 155 Subscription service ············································································································································ 155 Related information ······················································································································································ 155 Documents ···························································································································································· 155 Websites ······························································································································································· 155 Conventions ·································································································································································· 156 Index ········································································································································································ 158

FC and FCoE commands

Only the HP FlexFabric 5900CP-48XG-4QSFP+ Switches (JG838A) and HP StoreFabric 5900CP-48XG-4QSFP+8Gb FC B-fan Trays Converged Switches (E7W29A) support FC commands. FCoE mode commands display fcoe-mode Use display fcoe-mode to display the FCoE mode of the switch. Syntax display fcoe-mode Views Any view Predefined user roles network-admin network-operator Examples # Display the FCoE mode of the switch. display fcoe-mode The FCoE mode is FCF. display fcoe-mode The FCoE mode is NPV. display fcoe-mode The FCoE mode is TRANSIT. display fcoe-mode The FCoE mode is NONE. Related commands fcoe-mode fcoe-mode Use fcoe-mode to configure an FCoE mode for the switch. Use undo fcoe-mode to restore the default. Syntax fcoe-mode { fcf | npv | transit } undo fcoe-mode

A switch operates in non-FCoE mode and does not provide any FC or FCoE capabilities.

Views System view Predefined user roles network-admin Parameters fcf: Specifies the FCF mode. npv: Specifies the NPV mode. transit: Specifies the Transit mode. Usage guidelines The switch supports the following FCoE modes: • FCF mode—A switch operating in this mode is called an FCF switch. Its VFC interfaces support E mode (E_Port) and F mode (F_Port). • NPV mode—A switch operating in this mode is called an NPV switch. Its VFC interfaces support F mode (F_Port) and NP mode (NP_Port). • Transit mode—A switch operating in this mode is called a Transit switch. Its Ethernet interfaces can operate in ENode mode or FCF mode. An FC and FCoE-capable switch can operate in the following modes: • FCF mode—When the switch is operating in this mode, it can perform one of the following operations: � Connect to the E_Port on another FCF switch through its E_Port. � Connect to the N_Port on a node or the NP_Port on an NPV switch through its F_Port. • NPV mode—When the switch is operating in this mode, it can perform one of the following operations: � Connect to the N_Port on a node through its F_Port. � Connect to the F_Port on an FCF switch through its NP_Port. • Transit mode—When the switch is operating in this mode, you can do perform one of the following tasks: � Restrict its Ethernet interface to receiving traffic only from an ENode by configuring the interface to operate in ENode mode. � Restrict its Ethernet interface to receiving traffic only from an FCF switch by configuring the interface to operate in FCF mode. • Non-FCoE mode—When the switch is operating in this mode, it is a standard switch and does not provide any FC or FCoE capabilities. The switch can only convert from non-FCoE mode to one FCoE mode, or vice versa. It cannot convert directly among FCoE modes. To convert among FCoE modes, first convert the switch to non-FCoE mode. After converting the switch to non-FCoE mode, FC and FCoE-related configurations in the original FCoE mode are cleared. Examples # Configure the switch to operate in FCF mode.

[Sysname] fcoe-mode fcf

# Convert the switch operating in FCF mode to NPV mode. [Sysname] undo fcoe-mode All current FC configuration will be lost. Continue? [Y/N]:y [Sysname] fcoe-mode npv Related commands display fcoe-mode FC interface commands bandwidth Use bandwidth to configure the expected bandwidth of an FC interface. Use undo bandwidth to restore the default. Syntax bandwidth bandwidth-value undo bandwidth Default The expected bandwidth (in kbps) is the interface baud rate divided by 1000. Views FC interface view Predefined user roles network-admin Parameters bandwidth-value: Specifies the expected bandwidth in the range of 1 to 400000000 kbps. Usage guidelines The expected bandwidth of an interface affects the link costs in FSPF. You can control the route selection by configuring the expected bandwidth. Examples # Configure the expected bandwidth of interface FC 1/0/1 as 50 kbps. system-view [Sysname] interface fc 1/0/1 [Sysname-Fc1/0/1] bandwidth 50 default Use default to restore the default settings for an FC interface. Syntax default

FC interface view

Predefined user roles network-admin Usage guidelines CAUTION: The default command might interrupt ongoing network services. Make sure you are fully aware of the impacts of this command when you perform it on a live network. This command might fail to restore the default settings for some commands for reasons such as command dependencies or system restrictions. Use the display this command in interface view to identify these commands. Then use their undo forms or follow the command reference to restore their default settings. If your restoration attempt still fails, follow the error message instructions to resolve the problem. Examples # Restore the default settings for interface FC 1/0/1. system-view [Sysname] interface fc 1/0/1 [Sysname-Fc1/0/1] default description Use description to configure a description for an FC interface. Use undo description to restore the default. Syntax description text undo description Default The description of an FC interface is interface name Interface, for example, Fc1/0/1 Interface. Views FC interface view Predefined user roles network-admin Parameters text: Specifies an interface description, a case-sensitive string of 1 to 255 characters. Examples # Configure the description as Fcport1 for interface FC 1/0/1. system-view [Sysname] interface fc 1/0/1 [Sysname-Fc1/0/1] description Fcport1

display interface fc

Use display interface fc to display FC interface information. Syntax display interface [ fc ] [ brief [ down ] ] display interface [ fc [ interface-number ] ] [ brief [ description ] ] Views Any view Predefined user roles network-admin network-operator Parameters interface-number: Specifies an FC interface by its number. brief: Displays brief information about interfaces. If you do not specify this keyword, the command displays detailed information about interfaces. description: Displays complete interface descriptions. down: Displays information about the interfaces in physically down state and the causes. If you do not specify this keyword, the command displays information about interfaces in all states. Usage guidelines If you do not specify the fc interface-number option, this command displays information about all interfaces supported by the device. If you specify the fc keyword but not the interface-number argument, this command displays information about all FC interfaces. Examples # Display detailed information about interface FC 1/0/1. display interface fc 1/0/1 Fc1/0/1 Current state: UP Line protocol state: UP Description: Fc1/0/1 Interface Bandwidth: 4000000kbps Maximum Transmit Unit: 2112 4000Mbps-speed mode Internet protocol processing: disabled Link layer protocol is FC Fill word is idle-idle Port WWN is 66:66:66:62:65:34:30:39 FC mode is Auto, state is E Transmit B2B Credit is 64 Receive B2B Credit is 64 Support the VSAN protocol VSAN tagging mode is Non tagging

EVFP common VSAN : 1

Media type is optical fiber,Port hardware type is 16G_FC_SW_SFP Port priority: 0 4Gbps-speed mode, Link speed type is autonegotiation, Flow-control is enabled The Maximum Frame Length is 10000 Last clearing of counters: Never Peak value of input: 32 bytes/sec, at 2014-12-12 12:26:02 Peak value of output: 32 bytes/sec, at 2014-12-12 12:25:41 Last 300 seconds input: 0 packets/sec 9 bytes/sec 0% Last 300 seconds output: 0 packets/sec 9 bytes/sec 0% Input (total): 142 packets, 13596 bytes 142 unicasts, 0 broadcasts, 0 multicasts, 0 pauses Input (normal): 142 packets, - bytes 142 unicasts, 0 broadcasts, 0 multicasts, 0 pauses Input: 0 input errors, 0 runts, 0 giants, 0 throttles 0 CRC, 0 frame, - overruns, 0 aborts - ignored, - parity errors Output (total): 139 packets, 13748 bytes 139 unicasts, 0 broadcasts, 0 multicasts, 0 pauses Output (normal): 139 packets, - bytes 139 unicasts, 0 broadcasts, 0 multicasts, 0 pauses Output: 0 output errors, - underruns, - buffer failures 0 aborts, 0 deferred, 0 collisions, 0 late collisions 0 lost carrier, - no carrier Table 1 Command output Field Description Current state Physical state and administrative state of the FC interface: • Administratively Down—The interface is administratively shut down by using the shutdown command. • DOWN—The interface is administratively up but physically down. • DOWN (NPV uplink port not available)—The interface is administratively up but physically down, because its uplink interface is down or no uplink interface is created. • DOWN (SAN Aggregation interface down)—The interface is administratively up but physically down, because its FC aggregate interface is down. • UP—The interface is up both administratively and physically. Line protocol state Link layer protocol state of the FC interface: DOWN or UP. Description Description of the FC interface. Bandwidth Expected bandwidth of the FC interface. Maximum Transmit Unit MTU of the FC interface. 4000Mbps-speed mode Rate of the FC interface. Internet protocol processing IP packet processing capability. If the FC interface is not configured with an IP address, this field displays disabled. Link layer protocol Link layer protocol of the FC interface.

Fill word mode of the FC interface:

• idle-idle. • idle-arbff. FC mode Mode of the FC interface. state Operating mode of the FC interface through negotiation. Transmit B2B Credit BB_Credit value of the local end. This field is displayed only after the link comes up. Receive B2B Credit BB_Credit value of the remote end. This field is displayed only after the link comes up. Support VSAN Protocol The FC interface supports the VSAN protocol after negotiation. This field is displayed only after the link comes up. VSAN tagging mode VSAN tagging mode of the FC interface after the Exchange Virtual Fabrics Protocol (EVFP) negotiation: Tagging or Non tagging. This field is displayed only after the link comes up. EVFP common VSAN Common VSANs in up state through the EVFP negotiation. This field is displayed only after the link comes up. Link speed type is autonegotiation This field is displayed if the speed auto command is configured. Link speed type is force link This field is displayed if a specific rate is configured by using the speed command. Flow-control Flow control function status of the FC interface: • enabled. • not enabled. The Maximum Frame Length Maximum allowed frame size on the FC interface. Last clearing of counters Time when the interface statistics were last cleared by using the reset counters interface command. Never indicates that the interface statistics have never been cleared since switch startup. Peak value of input Peak incoming traffic rate on the FC interface. Peak value of output Peak outgoing traffic rate on the FC interface. Last 300 seconds input: 0 packets/sec 9 bytes/sec 0% Average incoming traffic rate on the FC interface in the last 300 seconds and the percentage of the actual rate to the maximum interface rate (configured by using the speed command). A hyphen (-) indicates that the statistics item is not supported. Last 300 seconds output: 0 packets/sec 9 bytes/sec 0% Average outgoing traffic rate on the FC interface in the last 300 seconds and the percentage of the actual rate to the maximum interface rate (configured by using the speed command). A hyphen (-) indicates that a statistics item is not supported.

Input (total): 142 packets, 13596

bytes 142 unicasts, 0 broadcasts, 0 multicasts, 0 pauses Total numbers of frames and bytes received on the FC interface, including normal frames, error frames, and pause frames. • unicasts—Number of frames received that are destined to unicast addresses. • broadcasts—Number of frames received that are destined to broadcast addresses. • multicasts—Number of frames received that are destined to multicast addresses. • pauses—Number of pause frames received. A hyphen (-) indicates that a statistics item is not supported. Input (normal): 142 packets, - bytes 142 unicasts, 0 broadcasts, 0 multicasts, 0 pauses Total number of normal frames received on the FC interface and total number of bytes of these frames, including normal frames and pause frames. • unicasts—Number of normal frames received that are destined to unicast addresses. • broadcasts—Number of normal frames received that are destined to broadcast addresses. • multicasts—Number of normal frames received that are destined to multicast addresses. • pauses—Number of pause frames received. A hyphen (-) indicates that a statistics item is not supported. input errors Total number of error frames received on the FC interface. runts Number of frames received that meet the following requirements: • Smaller than 64 bytes. • In correct format. • Have valid CRC values. giants Number of jumbo frames received. Jumbo frames are frames larger than the maximum allowed frame size. For an FC interface that does not permit jumbo frames, the maximum frame length is as follows: • 1518 bytes (without VLAN tags). • 1522 bytes (with VLAN tags). For an FC interface that permits jumbo frames, the maximum Ethernet frame length is configured when you configure jumbo frame support on the interface. throttles Number of times the switch shuts down the FC interface due to buffer or CPU overload. CRC Number of incoming frames that had a valid length but contained CRC errors. frame Number of incoming frames that contained CRC errors and a non-integer number of bytes. overruns Number of incoming frames dropped because the input rate of the FC interface exceeded the queuing capability.

Total number of illegal incoming frames:

• Fragment frames—CRC error frames shorter than 64 bytes. The length (in bytes) can be an integral or non-integral value. • Jabber frames—CRC error frames larger than the maximum frame allowed size on the FC interface (with an integral or non-integral length). � For an FC interface that does not permit jumbo frames, the maximum allowed frame size is 1518 bytes (without VLAN tags) or 1522 bytes (with VLAN tags). � For an FC interface that permits jumbo frames, the maximum allowed frame size is configured when you configure jumbo frame support on the interface. • Symbol error frames—Frames that contained at least one undefined symbol. • Unknown operation code frames—Non-pause MAC control frames. • Length error frames—Frames whose 802.3 length fields did not match the actual frame length (46 to 1500 bytes). ignored Number of incoming frames dropped because the receiving buffer of the port ran low. parity errors Number of incoming frames with parity errors. Output (total): 139 packets, 13748 bytes 139 unicasts, 0 broadcasts, 0 multicasts, 0 pauses Total numbers of frames and bytes sent on the FC interface, including normal frames, error frames, and pause frames. • unicasts—Number of frames sent that are destined to unicast addresses. • broadcasts—Number of frames sent that are destined to broadcast addresses. • multicasts—Number of frames sent that are destined to multicast addresses. • pauses—Number of pause frames sent. A hyphen (-) indicates that a statistics item is not supported. Output (normal): 139 packets, - bytes 139 unicasts, 0 broadcasts, 0 multicasts, 0 pauses Total number of normal frames sent on the FC interface and total number of bytes of these frames, including normal frames and pause frames. • unicasts—Number of normal frames sent that are destined to unicast addresses. • broadcasts—Number of normal frames sent that are destined to broadcast addresses. • multicasts—Number of normal frames sent that are destined to multicast addresses. • pauses—Number of pause frames sent. A hyphen (-) indicates that a statistics item is not supported. output errors Total number of error frames sent on the FC interface. underruns Number of outgoing frames dropped because the output rate of the FC interface exceeded the queuing capability. This is a low-probability hardware anomaly. buffer failures Number of frames dropped due to insufficient transmitting buffer resources.

Total number of frames that are not successfully sent for various reasons,

for example, collisions. deferred Number of frames that are delayed for transmission because collisions are detected before they are sent. collisions Number of frames that the FC interface stopped transmitting because collisions were detected during transmission. late collisions Number of frames that the FC interface deferred to transmit after transmitting their first 512 bits because of detected collisions. lost carrier Number of carrier losses during transmission. This counter increases by one when a carrier is lost, and applies to serial WAN interfaces. no carrier Number of times that the FC interface failed to detect the carrier when attempting to send frames. This counter increases by one each time the FC interface failed to detect the carrier, and applies to serial WAN interfaces. # Display brief information about interface FC 1/0/1. display interface fc 1/0/1 brief Brief information on FC interface(s): Admin Mode: auto - auto; E - e port; F - f port; NP - n port proxy Oper Mode: E - e port; F - f port; NP - n port proxy; TE - trunking e port; TF - trunking f port; TNP - trunking n port proxy Interface VSAN Admin Admin Oper Oper Status SAN-Aggregation Mode Trunk Mode Speed Mode Fc1/0/1 2 auto off E 4G UP SAGG23 Table 2 Command output Field Description Interface Name of the FC interface. VSAN Access VSAN of the FC interface. Admin Mode User-configured FC interface mode: • auto. • E. • F. • NP. Admin Trunk Mode User-configured trunk mode for the FC interface: • auto. • on. • off.

Negotiated mode (link layer negotiation) in which the FC interface is

operating: • E—The FC interface is operating in E mode as an access port. • F—The FC interface is operating in F mode as an access port. • NP—The FC interface is operating in NP mode as an access port. • TE—The FC interface is operating in E mode as a trunk port. • TF—The FC interface is operating in F mode as a trunk port. • TNP—The FC interface is operating in NP mode as a trunk port. If no negotiation is initiated or negotiation fails, this field displays two hyphens (--). Oper Speed Negotiated rate in bps (physical layer negotiation) for the FC interface. If no negotiation is initiated or negotiation fails, this field displays two hyphens (--). Status Negotiated state (link layer negotiation) for the FC interface: • UP. • DOWN. SAN-Aggregation FC aggregate group to which the FC interface belongs. This field is empty when the FC interface is not assigned to any FC aggregation group. # Display the descriptions of FC interfaces. display interface fc brief description Brief information on FC interface(s): Interface Description Fc1/0/2 Fc1/0/2 Interface Fc1/0/3 Fc1/0/3 Interface # Display information about and the causes of the FC interfaces in physically down state. display interface fc brief down Brief information on interface(s) under bridge mode: Link: ADM - administratively down; Stby - standby Interface Link Cause Fc1/0/1 ADM Administratively Table 3 Command output Field Description Brief information on interface(s) under bridge mode Brief information about Layer 2 interfaces. Link: ADM - administratively down; Stby - standby • ADM—The interface has been shut down by the network administrator. To bring up the interface, execute the undo shutdown command. • Stby—The interface is a standby interface. Interface Interface name.

Physical link state of the interface:

• UP—The interface is physically up. • DOWN—The interface is physically down. • ADM—The interface has been administratively shut down. To bring up the interface, execute the undo shutdown command. • Stby—The interface is a standby interface. Cause Causes for the physical state of the FC interface to be Down: • Not connected—No physical connection exists (possibly because the network cable is disconnected or faulty). • Administratively—The port was shut down by using the shutdown command. To bring up the interface, use the undo shutdown command. fc mode (FC interface view) Use fc mode to configure the mode of an FC interface. Use undo fc mode to restore the default. Syntax fc mode { auto | e | f | np } undo fc mode Default On an FCF switch, the mode of an FC interface is auto. On an NPV switch, the mode of an FC interface is F. Views FC interface view Predefined user roles network-admin Parameters auto: Specifies the auto mode, so that the FC interface can operate in F mode or E mode through dynamic negotiation. e: Specifies the E mode. f: Specifies the F mode. np: Specifies the NP mode. Usage guidelines An FC switch supports E, F, and auto modes. An NPV switch supports F and NP modes. Examples # Configure the mode of interface FC 1/0/1 as E. system-view [Sysname] interface fc 1/0/1

[Sysname-Fc1/0/1] fc mode e

fcb2bcredit Use fcb2bcredit to configure the Buffer-to-Buffer Credit (BB_ Credit) value for an FC interface. Use undo fcb2bcredit to restore the default. Syntax fcb2bcredit credit-value undo fcb2bcredit Default The BB_Credit value for an FC interface is 15. Views FC interface view Predefined user roles network-admin Parameters credit-value: Specifies the number of packets that the FC interface can continuously receive, in the range of 1 to 15. Usage guidelines The BB_ Credit is a flow control mechanism used to ensure that an FC interface does not drop packets. The BB_Credit value is configurable. Typically, you do not need to change the default value. Examples # Set the BB_Credit value to 10 for interface FC 1/0/1. system-view [Sysname] interface fc 1/0/1 [Sysname-Fc1/0/1] fcb2bcredit 10 fill-word Use fill-word to configure the fill word mode of an FC interface operating at 8 Gbps. Use undo fill-word to restore the default. Syntax fill-word { idle-arbff | idle-idle } undo fill-word Default The fill word mode is idle-arbff for an FC interface operating at 8 Gbps. Views FC interface view

Predefined user roles

network-admin Parameters idle-arbff: Specifies the idle-arbff mode. This mode uses the idle primitive signal in the link initialization phase and uses the ARBff primitive signal as the fill word. idle-idle: Specifies the idle-idle mode. This mode uses the idle primitive signal in the link initialization phase and uses the idle primitive signal as the fill word. Usage guidelines This command is available on only FC interfaces operating at 8 Gbps. This command does not take effect on FC interface operating at 2 Gbps or 4 Gbps, and these FC interfaces supports only the fill word mode idle-idle. When FC interfaces operating at 8 Gbps fail to communicate, you can use this command to adjust the fill word of these FC interfaces. To make the fill word mode configuration take effect, you must re-enable the FC interface by using the shutdown command and then the undo shutdown command. Examples # Configure the fill word mode as idle-idle for FC 1/0/1 operating at 8 Gbps. system-view [Sysname] interface fc 1/0/1 [Sysname-Fc1/0/1] speed 8000 [Sysname-Fc1/0/1] fill-word idle-idle Related commands speed interface fc Use interface fc to enter FC interface view. Syntax interface fc interface-number Views System view Predefined user roles network-admin Parameters interface-number: Specifies an FC interface by its number. Examples # Enter the view of interface FC 1/0/1. system-view [Sysname] interface fc 1/0/1 [Sysname-Fc1/0/1]

Use port-type to change a Layer 2 Ethernet interface to an FC interface or change an FC interface back

to a Layer 2 Ethernet interface. Syntax In Layer 2 Ethernet interface view: port-type fc In FC interface view: port-type ethernet Default A Layer 2 Ethernet interface is not changed to an FC interface. Views Layer 2 Ethernet interface view, FC interface view Predefined user roles network-admin Parameters ethernet: Changes an FC interface back to a Layer 2 Ethernet interface. fc: Changes a Layer 2 Ethernet interface to an FC interface. Usage guidelines Layer 2 Ethernet interfaces can be changed to FC interfaces. To change a Layer 2 Ethernet interface to an FC interface, use the port-type fc command in Layer 2 Ethernet interface view. To change an FC interface back to a Layer 2 Ethernet interface, use the port-type ethernet command in FC interface view. When the port type of an interface is changed, the following events occur: • The original interface is deleted. • A new interface is created with the same interface number as the original interface. Examples # Change interface Ten-GigabitEthernet 1/0/1 to interface FC 1/0/1. system-view [Sysname] interface ten-gigabitethernet 1/0/1 [Sysname-Ten-GigabitEthernet1/0/1] port-type fc [Sysname-Fc1/0/1] reset counters interface Use reset counters interface to clear statistics for FC interfaces. Syntax reset counters interface [ fc [ interface-number ] ]

Predefined user roles

network-admin Parameters interface-number: Specifies an FC interface by its number. Usage guidelines Use this command to clear history statistics if you want to collect traffic statistics for a specific time period. If you do not specify the fc keyword, this command clears statistics for all interfaces. If you specify the fc keyword, this command clears statistics for all FC interfaces. If you specify an FC interface, this command clears statistics for the specified FC interface. Examples # Clear statistics for interface FC 1/0/1. reset counters interface fc 1/0/1 Related commands display interface fc shutdown Use shutdown to shut down an FC interface. Use undo shutdown to bring up an FC interface. Syntax shutdown undo shutdown Default An FC interface is up. Views FC interface view Predefined user roles network-admin Examples # Shut down interface FC 1/0/1. system-view [Sysname] interface fc 1/0/1 [Sysname-Fc1/0/1] shutdown speed Use speed to configure the rate for an FC interface.

Use undo speed to restore the default.

Syntax speed { 1000 | 2000 | 4000 | 8000 | 16000 | auto } undo speed Default The rate of an FC interface is autonegotiated. Views FC interface view Predefined user roles network-admin Parameters 1000: Configures the interface rate as 1000 Mbps. 2000: Configures the interface rate as 2000 Mbps. 4000: Configures the interface rate as 4000 Mbps. 8000: Configures the interface rate as 8000 Mbps. 16000: Configures the interface rate as 16000 Mbps. auto: Configures the interface to negotiate its rate with the peer. Usage guidelines The switch series does not support the 1000 and 16000 keywords of the command. When you configure the 1000 or 16000 keyword for the command, the system prompts that "Such configuration is not supported." Examples # Set the rate to 8000 Mbps for interface FC 1/0/1. system-view [Sysname] interface fc 1/0/1 [Sysname-Fc1/0/1] speed 8000 VFC interface commands bandwidth Use bandwidth to configure the expected bandwidth of a VFC interface. Use undo bandwidth to restore the default. Syntax bandwidth bandwidth-value undo bandwidth Default The expected bandwidth (in kbps) is the interface baud rate divided by 1000.

VFC interface view

Predefined user roles network-admin Parameters bandwidth-value: Specifies the expected bandwidth in the range of 1 to 400000000 kbps. Usage guidelines The expected bandwidth determines the cost of the interface, which is used for route calculation. By default, the baud rate of a VFC interface is 10 Gbps. Examples # Set the expected bandwidth of interface VFC 1 to 50 kbps. system-view [Sysname] interface vfc 1 [Sysname-Vfc1] bandwidth 50 bind interface Use bind interface to bind a VFC interface to an Ethernet interface. Use undo bind interface to remove a VFC-to-Ethernet interface binding. Syntax bind interface interface-type interface-number [ mac mac-address ] undo bind interface Default A VFC interface is not bound to any Ethernet interface. Views VFC interface view Predefined user roles network-admin Parameters interface-type interface-number: Specifies an interface by its type and number. The interface type can be one of the following: • Layer 2 Ethernet interface. • Layer 2 aggregate interface. • S-channel interface. • S-channel aggregate interface. mac mac-address: Specifies the bound peer FCoE MAC address, in the format of XXXX-XXXX-XXXX and six bytes in length.

To make a VFC interface work, bind it to a physical Ethernet interface. The VFC interface sends and

receives packets through the Ethernet interface bound to it. To use one physical link to carry multiple VFC interfaces, you must bind these VFC interfaces to different peer FCoE MAC addresses. However, you can bind them to one Ethernet interface. The FCoE MAC address identifies the device that communicates with a VFC interface. For a point-to-multipoint network, the FCoE MAC address is required. For a point-to-point network, the FCoE MAC address is optional. You can use the display fcoe command to display the FCoE MAC address of a switch. You can display the FCoE MAC address of an ENode through some software or the NMS. A VFC interface can be bound to only one Ethernet interface and to only one FCoE MAC address. An Ethernet interface can be bound to multiple VFC interfaces, but an FCoE MAC address can be bound to only one VFC interface. You must change the switch to the expert mode before binding a VFC interface to an S-channel interface or S-channel aggregate interface. Otherwise, the binding will fail. The switch supports FCoE over S-channel capabilities only when it is operating in expert mode. For information about system operating modes, see Fundamentals Configuration Guide. For information about S-channel interfaces and S-channel aggregate interfaces, see EVB Configuration Guide. To successfully bind a VFC interface to a Layer 2 Ethernet interface, make sure the Layer 2 Ethernet interface is FCoE capable. To successfully bind a VFC interface to a Layer 2 aggregate interface, make sure all member ports of the Layer 2 aggregate interface are FCoE capable. New member ports of the Layer 2 aggregate interface must also be FCoE capable. To successfully bind a VFC interface to an S-channel interface, make sure the Layer 2 Ethernet interface associated with the S-channel interface has FCoE over S-channel capabilities. To successfully bind a VFC interface to an S-channel aggregate interface, make sure all member ports of the Layer 2 Ethernet aggregate interface associated with the S-channel aggregate interface have FCoE over S-channel capabilities. New member ports of the Layer 2 Ethernet aggregate interface must also have FCoE over S-channel capabilities. Otherwise, FCoE traffic might be blocked. For FCoE-capable cards and cards that have FCoE over S-channel capabilities, see the specific product manual. The binding to the Layer 2 aggregate interface does not take effect when you perform the following tasks: • Bind one VFC interface to a Layer 2 aggregate interface. • Bind another VFC interface to a Layer 2 Ethernet interface that is a member port of the Layer 2 aggregate interface. The binding to an S-channel aggregate interface does not take effect when you perform the following tasks: • Bind one VFC interface to the S-channel aggregate interface. • Bind another VFC interface to a member port of the Layer 2 aggregate interface associated with the S-channel aggregate interface. Enabling EVB on a Layer 2 Ethernet interface or Layer 2 aggregate interface disables the interface from forwarding FCoE traffic. To enable such an interface to forward FCoE traffic, you must create an S-channel interface or S-channel aggregate interface and bind a VFC interface to the created interface. FCoE over S-channel can be used only between an EVB-capable switch and a server. Examples # Bind interface VFC 4 to interface Ten-GigabitEthernet 1/0/1 and FCoE MAC address 000c-2999-eacd.

[Sysname] interface vfc 4

[Sysname-Vfc4] bind interface ten-gigabitethernet 1/0/1 mac 000c-2999-eacd # Bind interface VFC 5 to interface Bridge-aggregation 1 and FCoE MAC address 000c-2888-eacd. system-view [Sysname] interface vfc 5 [Sysname-Vfc5] bind interface bridge-aggregation 1 mac 000c-2888-eacd # Bind interface VFC 6 to interface S-Channel 1/0/1:10 and FCoE MAC address 000c-2999-eacd. system-view [Sysname]interface vfc 6 [Sysname-Vfc6] bind interface s-channel 1/0/1:10 mac 000c-2999-eacd # Bind interface VFC 7 to interface Schannel-Aggregation 1:10 and FCoE MAC address 000c-2666-eacd. system-view [Sysname]interface vfc 7 [Sysname-Vfc7] bind interface schannel-aggregation 1:10 mac 000c-2666-eacd Related commands • display fcoe • display interface vfc default Use default to restore the default settings for a VFC interface. Syntax default Views VFC interface view Predefined user roles network-admin Usage guidelines CAUTION: The default command might interrupt ongoing network services. Make sure you are fully aware of the impacts of this command when you execute it on a live network. This command might fail to restore the default settings for some commands for reasons such as command dependencies or system restrictions. Use the display this command in interface view to identify these commands. Then use their undo forms or follow the command reference to restore their default settings. If your restoration attempt still fails, follow the error message instructions to resolve the problem. Examples # Restore the default settings for interface VFC 1. system-view [Sysname] interface vfc 1 [Sysname-Vfc1] default

This command will restore the default settings. Continue? [Y/N]:y

description Use description to configure a description for a VFC interface. Use undo description to restore the default. Syntax description text undo description Default The description of an interface is interface name Interface, for example, Vfc 1 Interface. Views VFC interface view Predefined user roles network-admin Parameters text: Specifies an interface description, a case-sensitive string of 1 to 255 characters. Usage guidelines The description helps users identify the role of an interface. Examples # Configure the description as Vfcport1 for interface VFC 1. system-view [Sysname] interface vfc 1 [Sysname-Vfc1] description Vfcport1 Related commands display interface vfc display interface vfc Use display interface vfc to display VFC interface information. Syntax display interface [ vfc ] [ brief [ down ] ] display interface [ vfc [ interface-number ] ] [ brief [ description ] ] Views Any view Predefined user roles network-admin network-operator

interface-number: Specifies a VFC interface by its number in the range of 1 to 1024.

brief: Displays brief information about interfaces. If you do not specify this keyword, the command displays detailed information about interfaces. description: Displays complete interface descriptions. down: Displays information about the interfaces in physically down state and the causes. If you do not specify this keyword, the command displays information about interfaces in all states. Usage guidelines If you do not specify the vfc keyword, this command displays information about all interfaces supported by the switch. If you specify the vfc keyword, this command displays information about all VFC interfaces. If you specify a VFC interface, this command displays information about the specified VFC interface. Examples # Display detailed information about interface VFC 1. display interface vfc 1 Vfc1 Current state: UP Line protocol state: UP Description: Vfc1 Interface Bandwidth: 10000000kbps Maximum Transmit Unit: 2112 Internet protocol processing: disabled Link layer protocol is FC Port WWN is 66:66:66:63:66:64:61:30 FC mode is E, state is E Support the VSAN protocol VSAN tagging mode is Tagging EVFP common VSAN: 1 Bound interface is Ten-GigabitEthernet1/0/1, Bound MAC is 000c-2933-eacd VSAN of physical-UP state: 1 Last clearing of counters: Never Table 4 Command output Field Description Current state Physical state and administrative state of the VFC interface: • DOWN (Administratively)—The interface is administratively shut down by using the shutdown command. • DOWN—The interface is administratively up but physically down. • UP—The interface is up both administratively and physically. Line protocol state Link layer protocol state of the VFC interface: DOWN or UP. Bandwidth Expected bandwidth of the VFC interface. Internet protocol processing IP packet processing capability. If the VFC interface is not configured with an IP address, this field displays disabled.

Mode of the VFC interface.

state Operating mode of the VFC interface through negotiation. Support the VSAN protocol Indicates the VFC interface supports the VSAN protocol. VSAN tagging mode Link type of the interface: Trunk (Tagging) or Access (Non tagging). VFC interfaces support only Tagging. EVFP common VSAN Indicates that the common VSANs are in up state through the EVFP negotiation. This field is displayed only after the link goes up. Bound interface Physical interface bound to the VFC interface. Bound MAC FCoE MAC address bound to the VFC interface. VSAN of physical-UP state List of VSANs that are physically up. Last clearing of counters Time when the interface statistics were last cleared by using the reset counters interface command. Never indicates that the interface statistics have never been cleared since switch startup. # Display brief information about interface VFC 1. display interface vfc 1 brief Brief information on VFC interface(s): Admin Mode: auto - auto; E - e port; F - f port; NP - n port proxy Oper Mode: E - e port; F - f port; NP - n port proxy; TE - trunking e port; TF - trunking f port; TNP - trunking n port proxy Interface Admin Admin Oper Status Bind Mode Trunk Mode Interface Mode Vfc1 F on TF UP XGE1/0/1 0102-0304-0506 Table 5 Command output Field Description Interface Name of the VFC interface. Admin Mode User-configured VFC interface mode: • E. • F. • NP. Admin Trunk Mode User-configured trunk mode for the VFC interface: on.

Negotiated mode (link layer negotiation) in which the VFC interface is

operating: • E—The VFC interface is operating in E mode as an access port. • F—The VFC interface is operating in F mode as an access port. • NP—The VFC interface is operating in NP mode as an access port. • TE—The VFC interface is operating in E mode as a trunk port. • TF—The VFC interface is operating in F mode as a trunk port. • TNP—The VFC interface is operating in NP mode as a trunk port. If no negotiation is initiated or negotiation fails, this field displays two hyphens (--). Status Negotiated state (link layer negotiation) for the VFC interface: • UP. • DOWN. Bind Interface Ethernet interface and FCoE MAC address bound to the VFC interface. This field is empty when the VFC interface does not have bound Ethernet interface and FCoE MAC address. # Display the descriptions of VFC interfaces. display interface vfc brief description Brief information on VFC interface(s): Interface Description Vfc1 Vfc1 Interface Vfc2 Vfc2 Interface # Display information about and the causes of the VFC interfaces in physically down state. display interface vfc brief down Brief information on interface(s) under bridge mode: Link: ADM - administratively down; Stby - standby Interface Link Cause Vfc1 ADM Administratively Table 6 Command output Field Description Brief information on interface(s) under bridge mode Brief information about Layer 2 interfaces. Link: ADM - administratively down; Stby - standby • ADM—The interface has been shut down by the network administrator. To bring up the interface, execute the undo shutdown command. • Stby—The interface is a standby interface. Interface Interface name. Link Physical link state of the interface: • UP—The interface is physically up. • DOWN—The interface is physically down. • ADM—The interface has been administratively shut down. To bring up the interface, execute the undo shutdown command. • Stby—The interface is a standby interface.

Causes for the physical state of the VFC interface to be Down:

• Not connected—No physical connection exists (possibly because the network cable is disconnected or faulty). • Administratively—The port was shut down by using the shutdown command. To bring up the interface, use the undo shutdown command. fc mode (VFC interface view) Use fc mode to configure the mode of a VFC interface. Use undo fc mode to restore the default. Syntax fc mode { e | f | np } undo fc mode Default The mode of a VFC interface is F. Views VFC interface view Predefined user roles network-admin Parameters e: Specifies the E mode. f: Specifies the F mode. np: Specifies the NP mode. Usage guidelines An FCF switch supports E and F modes. An NPV switch supports F and NP modes. Examples # Configure the mode of interface VFC 1 as E. system-view [Sysname] interface vfc 1 [Sysname-Vfc1] fc mode e interface vfc Use interface vfc to create a VFC interface and enter its view. If the VFC interface already exists, this command leads you to VFC interface view directly. Use undo interface vfc to delete a VFC interface. Syntax interface vfc interface-number

undo interface vfc interface-number

Default No VFC interface exists. Views System view Predefined user roles network-admin Parameters interface-number: Specifies the number of the VFC interface, in the range of 1 to 1024. Usage guidelines A VFC interface is a logical interface manually created on the FCF switch to simulate the function of a physical FC interface. Examples # Create interface VFC 1 and enter its view. system-view [Sysname] interface vfc 1 [Sysname-Vfc1] Related commands display interface vfc reset counters interface Use reset counters interface to clear statistics for VFC interfaces. Syntax reset counters interface [ vfc [ number ] ] Views User view Predefined user roles network-admin Parameters number: Specifies a VFC interface by its number in the range of 1 to 1024. Usage guidelines Use this command to clear history statistics if you want to collect traffic statistics for a specific time period. If you do not specify the vfc keyword, this command clears statistics for all interfaces. If you specify the vfc keyword, this command clears statistics for all VFC interfaces. If you specify a VFC interface, this command clears statistics for the specified VFC interface. Examples # Clear statistics for interface VFC 1.

reset counters interface vfc 1

Related commands display interface vfc shutdown Use shutdown to shut down a VFC interface. Use undo shutdown to bring up a VFC interface. Syntax shutdown undo shutdown Default A VFC interface is up. Views VFC interface view Predefined user roles network-admin Examples # Bring up interface VFC 1. system-view [Sysname] interface vfc 1 [Sysname-Vfc1] undo shutdown FC link aggregation commands bandwidth Use bandwidth to configure the expected bandwidth of an FC aggregate interface. Use undo bandwidth to restore the default. Syntax bandwidth bandwidth-value undo bandwidth Default The expected bandwidth (in kbps) is the interface baud rate divided by 1000. Views FC aggregate interface view Predefined user roles network-admin

bandwidth-value: Specifies the expected bandwidth in the range of 1 to 400000000 kbps.

Usage guidelines The baud rate of an FC aggregate interface is the sum of the speed of each Selected member interface in the FC aggregation group. The expected bandwidth of an FC aggregate interface affects the link costs in FSPF. You can control the route selection by configuring the expected bandwidth. Examples # Set the expected bandwidth of FC aggregate interface 3 to 1000 kbps. system-view [Sysname] interface san-aggregation 3 [Sysname-SAN-Aggregation3] bandwidth 1000 default Use default to restore the default settings for an FC aggregate interface. Syntax default Views FC aggregate interface view Predefined user roles network-admin Usage guidelines CAUTION: The default command might interrupt ongoing network services. Make sure you are fully aware of the impacts of this command when you execute it on a live network. This command might fail to restore the default settings for some commands for reasons such as command dependencies and system restrictions. Use the display this command in interface view to identify these commands. Then use their undo forms or follow the command reference to restore their default settings. If your restoration attempt still fails, follow the error message instructions to resolve the problem. Examples # Restore the default settings for FC aggregate interface 3. system-view [Sysname] interface san-aggregation 3 [Sysname-SAN-Aggregation3] default This command will restore the default settings. Continue? [Y/N]:y description Use description to configure a description for an FC aggregate interface. Use undo description to restore the default.

The description of an FC aggregate interface is interface name Interface, for example,

SAN-Aggregation3 Interface. Views FC aggregate interface view Predefined user roles network-admin Parameters text: Specifies the interface description, a case-sensitive string of 1 to 255 characters. Examples # Configure the description as SAGG-interface for FC aggregate interface 3. system-view [Sysname] interface san-aggregation 3 [Sysname-SAN-Aggregation3] description SAGG-interface Related commands display interface san-aggregation display interface san-aggregation Use display interface san-aggregation to display FC aggregate interface information. Syntax display interface [ san-aggregation ] [ brief [ down ] ] display interface [ san-aggregation [ interface-number ] ] [ brief [ description ] ] Views Any view Predefined user roles network-admin network-operator Parameters interface-number: Specifies an FC aggregate interface by its number in the range of 1 to 1024. brief: Displays brief information about interfaces. If you do not specify this keyword, the command displays detailed information about interfaces. description: Displays complete interface descriptions. down: Displays information about the interfaces in physically down state and the causes. If you do not specify this keyword, the command displays information about the interfaces in all states.

If you do not specify the san-aggregation keyword, this command displays information about all

interfaces supported by the switch. If you specify the san-aggregation keyword, this command displays information about all FC aggregate interfaces. If you specify an FC aggregate interface, this command displays information about the specified FC aggregate interface. Examples # Display detailed information about FC aggregate interface 3. display interface san-aggregation 3 SAN-Aggregation3 Current state: UP Line protocol state: UP Description: SAN-Aggregation3 Interface Bandwidth: 0kbps Maximum Transmit Unit: 2112 Internet protocol processing: disabled Link layer protocol is FC Port WWN is 00:00:00:00:00:00:00:00 FC mode is Auto, state is Init Last clearing of counters: Never Table 7 Command output Field Description Current state Physical state and administrative state of the FC aggregate interface: • DOWN (Administratively)—The interface is administratively shut down by using the shutdown command. • DOWN—The interface is administratively up but physically down. • DOWN (NPV uplink port not available)—The interface is administratively up but physically down, because its uplink interface is down or no uplink interface is created. • UP—The interface is up both administratively and physically. Line protocol state Link layer protocol state of the FC aggregate interface: DOWN or UP. Bandwidth Expected bandwidth of the FC aggregate interface. Internet protocol processing IP packet processing capability. If the FC aggregate interface is not configured with an IP address, this field displays disabled. FC mode Mode of the FC aggregate interface. state Operating state of the FC aggregate interface through negotiation. Last clearing of counters Time when the interface statistics were last cleared by using the reset counters interface command. Never indicates that the interface statistics have never been cleared since switch startup. # Display brief information about FC aggregate interface 3. display interface san-aggregation 3 brief Brief information on SAN-Aggregation interface(s):

Admin Mode: auto - auto; E - e port; F - f port; NP - n port proxy

Oper Mode: E - e port; F - f port; NP - n port proxy; TE - trunking e port; TF - trunking f port; TNP - trunking n port proxy Interface VSAN Admin Admin Oper Oper Status Mode Trunk Mode Speed Mode SAGG3 37 NP auto NP 4G UP Table 8 Command output Field Description Interface Name of the FC aggregate interface. VSAN Access VSAN of the FC aggregate interface. Admin Mode User-configured FC aggregate interface mode: • auto. • E. • F. • NP. Admin Trunk Mode User-configured trunk mode for the FC aggregate interface: • auto. • on. • off. Oper Mode Negotiated mode (link layer negotiation) in which the FC aggregate interface is operating: • E—The FC aggregate interface is operating in E mode as an access port. • F—The FC aggregate interface is operating in F mode as an access port. • NP—The FC aggregate interface is operating in NP mode as an access port. • TE—The FC aggregate interface is operating in E mode as a trunk port. • TF—The FC aggregate interface is operating in F mode as a trunk port. • TNP—The FC aggregate interface is operating in NP mode as a trunk port. If no negotiation is initiated or negotiation fails, this field displays two hyphens (--). Oper Speed Negotiated rate in bps (physical layer negotiation) for the FC aggregate interface. If no negotiation is initiated or negotiation fails, this field displays two hyphens (--). Status Negotiated state (link layer negotiation) for the FC aggregate interface: • UP. • DOWN. # Display the descriptions of FC aggregate interfaces. display interface san-aggregation brief description Brief information on SAN-Aggregation interface(s):

SAGG1 SAN-Aggregation1 Interface

SAGG2 SAN-Aggregation2 Interface # Display information about the FC aggregate interfaces in physically down state and the causes. display interface san-aggregation brief down Brief information on interface(s) under bridge mode: Link: ADM - administratively down; Stby - standby Interface Link Cause SAGG3 ADM Administratively Table 9 Command output Field Description Brief information on interface(s) under bridge mode Brief information about Layer 2 FC aggregate interfaces. Link: ADM - administratively down; Stby - standby • ADM—The interface has been shut down by the network administrator. To bring up the interface, execute the undo shutdown command. • Stby—The interface is a standby interface. Interface Interface name. Link Physical link state of the FC aggregate interface: • UP—The interface is physically up. • DOWN—The interface is physically down. • ADM—The interface has been administratively shut down. To bring up the interface, execute the undo shutdown command. • Stby—The interface is a standby interface. Cause Causes for the physical state of the FC aggregate interface to be Down: • Not connected—No physical connection exists (possibly because the network cable is disconnected or faulty). • Administratively—The port was shut down by using the shutdown command. To bring up the interface, use the undo shutdown command. display san-aggregation Use display san-aggregation to display information about FC aggregation groups corresponding to existing FC aggregate interfaces. Syntax display san-aggregation [ verbose ] [ interface san-aggregation interface-number ] Views Any view Predefined user roles network-admin network-operator

verbose: Displays detailed information about FC aggregation groups. If you do not specify this keyword,

the command displays brief information about the FC aggregation groups. interface san-aggregation interface-number: Specifies an FC aggregate interface by its number. The value range for the interface-number argument is 1 to 1024. If you do not specify an FC aggregate interface, this command displays information about all FC aggregation groups corresponding to existing FC aggregate interfaces. Examples # Display brief information about all FC aggregation groups corresponding to existing FC aggregate interfaces. display san-aggregation * indicates the member port is selected. Interface State Mode Speed Member port SAGG1 UP E 8Gbps *Fc1/0/1 Fc1/0/2 SAGG2 DOWN - - - Table 10 Command output Match criteria Description Interface Abbreviated FC aggregate interface name. State Physical state of the FC aggregate interface: • DOWN—The physical state of the interface is down and the FC aggregate interface contains no Selected member interface. • UP—The physical state of the interface is up and the FC aggregate interface contains Selected member interfaces. Mode Operating mode of the FC aggregate interface: • E—E mode. • F—F mode. • NP—NP mode. When the physical state of the FC aggregate interface is down, a hyphen (-) is displayed for this field. Speed Speed of the FC aggregate interface. It is the sum of the speed of each Selected member interface. When the physical state of the FC aggregate interface is down, a hyphen (-) is displayed for this field. Member port Member interfaces of the FC aggregation group corresponding to the FC aggregate interface. A member interface marked with an asterisk (*) is a Selected member interface. When the FC aggregation group does not contain any member interface, a hyphen (-) is displayed for this field. # Display detailed information about all FC aggregation groups corresponding to existing FC aggregate interfaces. display san-aggregation verbose Interface SAN-Aggregation1: State : UP Mode : E Speed : 2Gbps Member port number : 2

Selected port number : 1

Member port State Mode Speed Selected Fc1/0/1 UP E 2Gbps Y Fc1/0/2 UP E 1Gbps N Interface SAN-Aggregation2: State : DOWN Mode : N/A Speed : N/A Member port number : 2 Selected port number : 0 Member port State Mode Speed Selected Fc1/0/3 DOWN - - N Fc1/0/4 DOWN - - N Table 11 Command output Match criteria Description Interface FC aggregate interface name. State Physical state of the FC aggregate interface: • DOWN—The physical state of the interface is down and the FC aggregate interface contains no Selected member interface. • UP—The physical state of the interface is up and the FC aggregate interface contains Selected member interfaces. Mode Operating mode of the FC aggregate interface: • E—E mode. • F—F mode. • NP—NP mode. When the physical state of the FC aggregate interface is down, N/A is displayed for this field. Speed Speed of the FC aggregate interface. It is the sum of the speed of each Selected member interface. When the physical state of the FC aggregate interface is down, N/A is displayed for this field. Member port number Number of member interfaces in the FC aggregation group corresponding to the FC aggregate interface. Selected port number Number of Selected member interfaces in the FC aggregation group corresponding to the FC aggregate interface. Member port Member interfaces of the FC aggregation group corresponding to the FC aggregate interface. When the FC aggregation group does not contain any member interface, this field is blank. State Link layer state of the FC aggregate interface: • DOWN—The link layer protocol of the interface is down. • UP—The link layer protocol of the interface is up.

Operating mode of the member interface:

• E—E mode. • F—F mode. • NP—NP mode. When the member interface is down at the link layer, a hyphen (-) is displayed for this field. Speed Speed of the member interface. When the member interface is down at the link layer, a hyphen (-) is displayed for this field. Selected Selected state of the member interface: • N—Unselected. • Y—Selected. fc mode (FC aggregate interface view) Use fc mode to configure the mode of an FC aggregate interface. Use undo fc mode to restore the default. Syntax fc mode { auto | e | f | np } undo fc mode Default On an FCF switch, the mode of an FC aggregate interface is auto. On an NPV switch, the mode of an FC aggregate interface is F. Views FC aggregate interface view Predefined user roles network-admin Parameters auto: Specifies the auto mode, so that the FC aggregate interface can operate in F mode or E mode through dynamic negotiation. e: Specifies the E mode. f: Specifies the F mode. np: Specifies the NP mode. Usage guidelines An FCF switch supports E, F, and auto modes. An NPV switch supports F and NP modes. Examples # Configure the mode of FC aggregate interface 3 as E. system-view [Sysname] interface san-aggregation 3

[Sysname-SAN-Aggregation3] fc mode e

interface san-aggregation Use interface san-aggregation to create an FC aggregate interface and enter its view. If the FC aggregate interface already exists, this command leads you to the FC aggregate interface view directly. Syntax interface san-aggregation interface-number undo interface san-aggregation interface-number Default No FC aggregate interfaces exist. Views System view Predefined user roles network-admin Parameters interface-number: Specifies the number of the FC aggregate interface. The value range for this argument is 1 to 1024. Examples # Enter the view of FC aggregate interface 3. system-view [Sysname] interface san-aggregation 3 [Sysname-SAN-Aggregation3] Related commands display interface san-aggregation reset counters interface Use reset counters interface to clear statistics for FC aggregate interfaces. Syntax reset counters interface [ san-aggregation [ number ] ] Views User view Predefined user roles network-admin Parameters number: Specifies an FC aggregate interface by its number. The value range for this argument is 1 to 1024. Usage guidelines Use this command to clear history statistics if you want to collect traffic statistics for a specific time period.

If you do not specify the san-aggregation keyword, this command clears statistics for all interfaces.

If you specify the san-aggregation keyword, this command clears statistics for all FC aggregate interfaces. If you specify an FC aggregate interface, this command clears statistics for the specified FC aggregate interface. Examples # Clear statistics for FC aggregate interface 3. reset counters interface san-aggregation 3 Related commands display interface san-aggregation san-aggregation group Use san-aggregation group to assign an FC interface to an FC aggregation group. Use undo san-aggregation group to remove an FC interface from an FC aggregation group. Syntax san-aggregation group group-number undo san-aggregation group Default An FC interface is not assigned to any FC aggregation group. Views FC interface view Predefined user roles network-admin Parameters group-number: Specifies an FC aggregation group by its group number. An FC aggregation group uniquely corresponds to an FC aggregate interface, and they are numbered the same. Usage guidelines An FC interface can be assigned to only one FC aggregation group. After an FC interface is assigned to an FC aggregation group, its operating mode, trunk mode, trunk VSAN, and access VSAN configurations are cleared. Also, you cannot configure these configurations for a member interface. After the FC interface is removed from the FC aggregation group, these configurations are not restored, and the default settings of these configurations are used. An FC aggregation group can have a maximum of eight member interfaces. Examples # Assign FC interface FC 1/0/1 to FC aggregation group 2. system-view [Sysname] interface fc 1/0/1 [Sysname-Fc1/0/1] san-aggregation group 2 Current FC mode, trunk mode, trunk VSAN, and access VSAN configuration of the in

terface will be lost. Continue? [Y/N]:y

Related commands display san-aggregation san-aggregation load-sharing mode local-first Use san-aggregation load-sharing mode local-first to enable local-first load sharing. Use undo san-aggregation load-sharing mode local-first to disable local-first load sharing. Syntax san-aggregation load-sharing mode local-first undo san-aggregation load-sharing mode local-first Default Local-first load sharing is enabled. Views System view Predefined user roles network-admin Usage guidelines Local-first load sharing reduces the influence of traffic on the links between physical IRF ports. For example, in an IRF fabric, an IRF member device forwards traffic out of an FC aggregate interface with the member interfaces distributed on multiple IRF member devices. The system processes the traffic as follows based on the configurations on IRF member device. • When local-first load sharing is enabled on the IRF member device, the following rules apply: � If the IRF member device has Selected member interfaces, traffic is load-shared among the Selected interfaces of the IRF member device. � If the IRF member device does not have Selected member interface, traffic is load-shared among all Selected member interfaces on all IRF member devices. • When local-first load sharing is disabled on the IRF member device, the traffic is load-shared among all Selected member interfaces on all IRF member devices. For more information about IRF, see IRF Configuration Guide. Local-first load sharing takes effect immediately after it is configured, and it might cause traffic loss. Examples # Enable local-first load sharing. system-view [Sysname] san-aggregation load-sharing mode local-first shutdown Use shutdown to shut down an FC aggregate interface. Use undo shutdown to bring up an FC aggregate interface.

An FC aggregate interface is up.

Views FC aggregate interface view Predefined user roles network-admin Examples # Bring up FC aggregate interface 3. system-view [Sysname] interface san-aggregation 3 [Sysname-SAN-Aggregation3] undo shutdown FCoE commands display fcoe Use display fcoe to display global FCoE configuration. Syntax display fcoe Views Any view Predefined user roles network-admin network-operator Examples # Display global FCoE configuration. display fcoe FCoE MAC : 0000-1234-0202 FC-MAP : 0efc25 FCF Priority: 128 FKA period : 8 seconds Table 12 Command output Field Description FCoE MAC FCoE MAC address of the switch. FC-MAP FC-MAP value. FCF Priority System FCF priority.

Interval at which a VFC interface sends Discovery Solicitations

and unsolicited Discovery Advertisements. Related commands • fcoe fcmap • fcoe fka-adv-period • fcoe global fcf-priority fcoe enable Use fcoe enable to enable FCoE for a VLAN and map the VLAN to a VSAN. Use undo fcoe enable to disable FCoE for the VLAN. Syntax fcoe enable [ vsan vsan-id ] undo fcoe enable Default FCoE is disabled for a VLAN. Views VLAN view Predefined user roles network-admin Parameters vsan vsan-id: Specifies a VSAN by its ID in the range of 1 to 3839. If you do not specify a VSAN, this command maps the VLAN to a VSAN with the same ID as the VLAN. For VLANs 3840 to 4094, you must specify VSANs to be mapped. Usage guidelines To use an FC or VFC interface to transmit packets, you must enable FCoE. When you use an FC interface to transmit packets, you must map its access VSAN and trunk VSANs to VLANs and enable FCoE for the VLANs. This allows the switch to correctly run FC and FCoE features. When you use a VFC interface to transmit packets, the Ethernet interface bound to the VFC interface might allow multiple VLANs. You must enable FCoE for a VLAN and map the VLAN to a VSAN. This allows the packets from the VSAN to be tagged with the VLAN tag and transmitted within the VLAN. FCoE cannot be enabled for VLAN 1. VSANs are mapped to VLANs on a one-to-one basis. When you use an FC interface to transmit packets, the VSAN used on the two ends can be mapped to the same VLAN or different VLANs. When you use a VFC interface to transmit packets, enable FCoE for the same VLAN and map this VLAN to the same VSAN on the two ends. After you enable FCoE for a VLAN, the following changes occur to the VLAN: • An FCoE-capable VLAN allows only FCoE traffic.

All member ports in an FCoE-capable VLAN are isolated and will not form loops. For this reason,

you do not need to enable STP or other loop detection protocols in an FCoE-capable VLAN. Otherwise, FCoE links might be blocked. • A Layer 2 protocol enabled in an FCoE-capable VLAN runs based on the topology where all member ports in the FCoE-capable VLAN are isolated at Layer 2. Examples # Enable FCoE on VLAN 4 and map VLAN 4 to VSAN 6. system-view [Sysname] vlan 4 [Sysname-vlan4] fcoe enable vsan 6 fcoe fcf-priority Use fcoe fcf-priority to configure the FCF priority for a VFC interface. Use undo fcoe fcf-priority to restore the default. Syntax fcoe fcf-priority priority undo fcoe fcf-priority Default The FCF priority of a VFC interface is 128. Views VFC interface view Predefined user roles network-admin Parameters priority: Specifies the FCF priority for the VFC interface, in the range of 0 to 255. The smaller the value, the higher the priority. Usage guidelines The VFC interface FCF priority is used in the fcf priority field in an unsolicited Discovery Advertisement. An ENode selects the FCF switch with the highest priority from the FCF switches sending Discovery Advertisements and sends a FLOGI request to it for login. This command is takes effect on only VFC interfaces operating in F mode. You can configure this command on VFC interfaces operating in E mode, but it does not take effect. Examples # Configure the FCF priority as 12 for interface VFC 1. system-view [Sysname] interface vfc 1 [Sysname-Vfc1] fcoe fcf-priority 12

Use fcoe fcmap to configure an FC-MAP value.

Use undo fcoe fcmap to restore the default. Syntax fcoe fcmap fc-map undo fcoe fcmap Default The FC-MAP value is 0x0EFC00. Views System view Predefined user roles network-admin Parameters fc-map: Specifies an FC-MAP value in the range of 0x0EFC00 to 0x0EFCFF. Usage guidelines An FC-MAP value identifies an FCoE network. Switches in the same FCoE network must have the same FC-MAP value. After an FC-MAP value is configured, VFC interfaces perform an FIP renegotiation. Examples # Configure the FC-MAP value as 0x0EFCFF. system-view [Sysname] fcoe fcmap 0efcff Changing the FC-MAP will flap all VFC interfaces. Continue? [Y/N]: fcoe fka-adv-period Use fcoe fka-adv-period to configure an FKA advertisement interval. Use undo fcoe fka-adv-period to restore the default. Syntax fcoe fka-adv-period fka-adv-period undo fcoe fka-adv-period Default The FKA advertisement interval is 8 seconds. Views System view Predefined user roles network-admin

fka-adv-period: Specifies an FKA advertisement interval value in the range of 4 to 600 seconds.

Usage guidelines The FKA advertisement interval determines the length of time the switch takes to detect the disconnection of a virtual link. The FKA advertisement interval defines the interval for a switch to send unsolicited Discovery Advertisements to its peer switches or ENodes. If the peer switch or ENode fails to receive unsolicited Discovery Advertisements within 2.5 FKA advertisement intervals, it deletes the virtual link. The FKA advertisement interval is carried in received unsolicited Discovery Advertisements instead of being configured on the local switch. If the switch fails to receive keepalive frames from the peer ENode within 2.5 FKA advertisement intervals, it also deletes the virtual link. When configuring the FKA advertisement interval value on an FCF or NPV switch, use Table 13 as a reference to avoid service disruption. Table 13 Recommended values for different application scenarios Recommended value Application scenarios Remarks Less than 90 seconds Connected to servers, storage devices, or third-party switches. According to FC-BB-5, the upper limit of the FKA advertisement interval value is 90 seconds. In this scenario, an FCF switch or NPV switch operating in standalone mode or in IRF mode but without subordinate switches will experience FCoE traffic disruption during an ISSU reboot for the following reasons: • The ISSU reboot takes more than 225 (2.5*90) seconds. • The peer deletes the virtual link for failing to receive unsolicited Discovery Advertisements within 225 seconds. You must adjust the FKA advertisement interval value on the upstream FCF switch to ensure service continuity in either of the following situations: • An active/standby switchover on an NPV switch • An ISSU reboot on an IRF member NPV switch with subordinate switches. The preceding steps are required for the following reasons: • The FKA advertisement interval value configured on the NPV switch affects only its VFC interfaces in F mode and connected ENodes. • The VFC interfaces in NP mode of the NPV switch use the FKA advertisement interval value learned from the upstream FCF switch.

Active/standby switchover on

the switch takes more than 2.5 x 60 seconds because of the amount of FCoE configuration. ISSU reboot on an IRF member switch with subordinate switches takes more than 2.5 x 60 seconds because of the amount of FCoE configuration. For more information about ISSU, see Fundamentals Configuration Guide. 300–600 seconds ISSU reboot on a switch operating in standalone mode or in IRF mode but without subordinate switches and connecting to no nodes. During an ISSU reboot on a switch operating in standalone mode or in IRF mode but without subordinate switches, the switch cannot send unsolicited Discovery Advertisements or keepalive frames. Examples # Configure the FKA advertisement interval as 20 seconds. system-view [Sysname] fcoe fka-adv-period 20 fcoe global fcf-priority Use fcoe global fcf-priority to configure the system FCF priority. Use undo fcoe global fcf-priority to restore the default. Syntax fcoe global fcf-priority priority undo fcoe global fcf-priority Default The system FCF priority is 128. Views System view Predefined user roles network-admin Parameters priority: Specifies the system FCF priority in the range of 0 to 255. The smaller the value, the higher the priority. Usage guidelines The system FCF priority is used in the fcf priority field in an unsolicited Discovery Advertisement. An ENode selects the FCF switch with the highest priority from the FCF switches sending Discovery Advertisements and sends a FLOGI request to it for login. This command takes effect on all VFC interfaces operating in F mode.

# Configure the system FCF priority as 12.

system-view [Sysname] fcoe global fcf-priority 12 VSAN commands display vsan port-member Use display vsan port-member to display the member interfaces of a VSAN. Syntax display vsan [ vsan-id ] port-member Views Any view Predefined user roles network-admin network-operator Parameters vsan-id: Specifies a VSAN by its ID in the range of 1 to 3839. If you do not specify a VSAN, this command displays the member interfaces of each VSAN. Examples # Display the member interfaces of each VSAN. display vsan port-member VSAN 1: Access Ports: Fc1/0/1 Fc1/0/2 Fc1/0/3 Fc1/0/4 Fc1/0/5 Fc1/0/6 Trunk Ports: Fc1/0/4 Fc1/0/5 Fc1/0/6 Vfc2 VSAN 2: Access Ports: Trunk Ports: Fc1/0/4 VSAN 10: Access Ports: Trunk Ports: VSAN 100: Access Ports: Trunk Ports:

Fc1/0/4 Fc1/0/5 Fc1/0/6

port Use port to assign the specified interfaces to a VSAN as access ports in batch. Use undo port to remove the specified interfaces from a VSAN in batch. Syntax port interface-list undo port interface-list Default All interfaces belong to VSAN 1 as access ports. Views VSAN view Predefined user roles network-admin Parameters interface-list: Specifies a space-separated list of up to 10 interface items. Each item specifies an interface or a range of interfaces in the form of interface-type interface-number1 to interface-type interface-number2. The value for interface-number2 must be greater than or equal to the value for interface-number1. The interface type can only be FC interface. Usage guidelines This command has the same effect as configuring the port access vsan command in interface view of each interface in the interface list. Examples # Assign interfaces FC 1/0/1 through FC 1/0/10 to VSAN 10 as access ports in batch. system-view [Sysname] vsan 10 [Sysname-vsan10] port fc 1/0/1 to fc 1/0/10 Related commands port access vsan port access vsan Use port access vsan to assign an interface to a VSAN as an access port. Use undo port access vsan to restore the default. Syntax port access vsan vsan-id undo port access vsan Default The access VSAN of each interface is VSAN 1.

FC interface view, FC aggregate interface view

Predefined user roles network-admin Parameters vsan-id: Specifies a VSAN by its ID in the range of 1 to 3839. Make sure the VSAN already exists on the switch. Otherwise, this command fails. Usage guidelines To assign multiple interfaces to a VSAN as access ports in batch, use the port command. Examples # Assign interface FC 1/0/1 to VSAN 10 as an access port. system-view [Sysname] vsan 10 [Sysname-vsan10] quit [Sysname] interface fc 1/0/1 [Sysname-Fc1/0/1] port access vsan 10 Related commands port port trunk mode Use port trunk mode to configure the trunk mode of an interface. Use undo port trunk mode to restore the default. Syntax port trunk mode { auto | off | on } undo port trunk mode Default On an FCF switch, the trunk mode of an interface is auto. On an NPV switch, the trunk mode of an interface is off. Views FC interface view, FC aggregate interface view Predefined user roles network-admin Parameters auto: Specifies the auto mode. off: Specifies the off mode. on: Specifies the on mode. Usage guidelines The trunk mode of an interface can be auto, on, or off.

When the switch is operating in FCF mode, its FC interfaces and FC aggregate interfaces support

all these modes. • When the switch is operating in NPV mode, its FC interfaces and FC aggregate interfaces support only on and off modes. The two interfaces of a link use the Exchange Virtual Fabrics Parameters (EVFP) protocol to negotiate whether to support VSAN tagging according to the trunk modes. Only FC interfaces and FC aggregate interfaces support the trunk mode. Examples # Configure the trunk mode of interface FC 1/0/1 as On. system-view [Sysname] interface fc 1/0/1 [Sysname-Fc1/0/1] port trunk mode on port trunk vsan Use port trunk vsan to assign an interface to the specified VSANs as a trunk port. Use undo port trunk vsan to remove an interface from the specified VSANs. Syntax port trunk vsan vsan-id-list undo port trunk vsan vsan-id-list Default An interface is not assigned to any VSAN as a trunk port. Views FC interface view, VFC interface view, FC aggregate interface view Predefined user roles network-admin Parameters vsan-id-list: Specifies a space-separated list of up to 10 VSAN items. Each item specifies a VSAN or a range of VSANs in the form of vsan-id1 to vsan-id2. The value for vsan-id2 must be greater than or equal to the value for vsan-id1. Examples # Assign interface FC 1/0/1 to VSANs 1, 2, 10, and 20 through 100. system-view [Sysname] interface fc 1/0/1 [Sysname-Fc1/0/1] port trunk vsan 1 to 2 10 20 to 100 # Assign interface VFC 1 to VSANs 1, 2, 10, and 20 through 100. system-view [Sysname] interface vfc 1 [Sysname-Vfc1] port trunk vsan 1 to 2 10 20 to 100

Use vsan to create a VSAN and enter VSAN view. If the VSAN already exists, this command directly

leads you to VSAN view. Use undo vsan to delete a VSAN. Syntax vsan vsan-id undo vsan vsan-id Default Only the default VSAN (VSAN 1) exists. Views System view Predefined user roles network-admin Parameters vsan vsan-id: Specifies a VSAN by its ID in the range of 1 to 3839. Usage guidelines You cannot create or delete VSAN 1, because it is the system-default VSAN. You can create VSANs 2 to 3839. The maximum number of VSANs (including VSAN 1) that can be created is 16. Examples # Create VSAN 10 and enter its view. system-view [Sysname] vsan 10 [Sysname-vsan10] Fabric building commands allowed-domain-id Use allowed-domain-id to configure an allowed domain ID list for a VSAN. Use undo allowed-domain-id to restore the default. Syntax allowed-domain-id domain-id-list undo allowed-domain-id domain-id-list Default The allowed domain ID list includes domain IDs 1 to 239.

Predefined user roles

network-admin Parameters domain-id-list: Specifies a space-separated list of up to 8 domain items. Each item specifies a domain ID or a range of domain IDs in the form of domain-id1 to domain-id2. The value for domain-id2 must be greater than or equal to the value for domain-id1. The value range for the domain-id argument is 1 to 239. Usage guidelines Each FC switch is assigned a domain ID. You can configure an allowed domain ID list. To successfully configure an allowed domain ID list on the principal switch, make sure all assigned and locally configured domain IDs are included in the list. After you configure an allowed domain ID list, the principal switch assigns only domain IDs available in the allowed list. To successfully configure an allowed domain ID list on a non-principal switch, make sure the runtime domain ID of the switch is included in the allowed list. After you configure an allowed domain ID list on a non-principal switch, the following rules apply: • The locally configured domain ID must be included in the allowed list. Otherwise, the domain ID configuration fails. • The principal switch must assign a domain ID that is included in the allowed list of the non-principal switch. Otherwise, the non-principal switch refuses the assigned domain ID and isolates its interface connected to the principal switch. HP recommends that you configure the same allowed domain ID list for all switches in a VSAN. Examples # Configure VSAN 1 to allow domains 3 through 10. system-view [Sysname] vsan 1 [Sysname-vsan1] allowed-domain-id 3 to 10 display fc domain Use display fc domain to display the domain information of a VSAN. Syntax display fc domain [ vsan vsan-id ] Views Any view Predefined user roles network-admin network-operator

vsan vsan-id: Specifies a VSAN by its ID in the range of 1 to 3839. If you do not specify a VSAN, this

command displays the domain information of all VSANs. Usage guidelines The displayed domain information includes runtime and configuration information of the local switch and runtime information of the principal switch. Examples # Display the domain information of VSAN 1. display fc domain vsan 1 Domain Information of VSAN 1: Running time information: State: Stable Switch WWN: 41:6e:64:69:61:6d:6f:21 Fabric name: 41:6e:64:69:61:6d:6f:21 Priority: 2 Domain ID: 100 Configuration information: Domain configure: Enabled Domain auto-reconfigure: Disabled Fabric name: 41:6e:64:69:61:6d:6f:21 Priority: 128 Domain ID: 100 (static) Principal switch running time information: Priority: 2 Path Interface Downstream Fc1/0/1 Downstream Fc1/0/2 Downstream Fc1/0/4 Table 14 Command output Field Description State Running status: • Stable—The configuration is finished. • Unstable—The configuration is not finished. Switch WWN WWN of the local switch. Fabric name Name of the fabric. Priority Running priority of the local switch. Domain ID Runtime domain ID of the local switch. Configuration information Configuration information of the local switch. Domain configure State of the fabric configuration function: • Enabled—The fabric configuration function is enabled. • Disabled—The fabric configuration function is disabled.

State of the automatic reconfiguration function:

• Enabled—The automatic reconfiguration function is enabled on the switch. • Disabled—The automatic reconfiguration function is disabled on the switch. Fabric name Fabric name configured on the switch. Priority Locally configured priority of the switch. Domain ID Locally configured domain ID. The field in the parentheses can be one of the following: • static—The domain ID is static type. • preferred—The domain ID is preferred type. Principal switch running time information Runtime information of the principal switch. Priority Running priority of the principal switch. Path Path type of the interface: • Upstream—Upstream principal link. • Downstream—Downstream principal link. Interface Local FC or VFC interface. display fc domain-list Use display fc domain-list to display the list of domain IDs dynamically assigned in a VSAN. Syntax display fc domain-list [ vsan vsan-id ] Views Any view Predefined user roles network-admin network-operator Parameters vsan vsan-id: Specifies a VSAN by its ID in the range of 1 to 3839. If you do not specify a VSAN, this command displays the lists of domain IDs dynamically assigned in all VSANs. Usage guidelines For a dynamically built fabric, this command displays the list of domain IDs dynamically assigned in a VSAN and includes the following information: • The total number of domains. • Mappings between domain IDs and switch WWNs. Examples # Display the list of domain IDs dynamically assigned in VSAN 1. display fc domain-list vsan 1

Domain list of VSAN 1:

Number of domains: 3 Domain ID WWN 0xc8(200) 20:01:00:05:30:00:47:df [Principal] 0x63(99) 20:01:00:0d:ec:08:60:c1 [Local] 0x61(97) 50:00:53:0f:ff:f0:10:06 Table 15 Command output Field Description Domain list of VSAN Domain ID list of the VSAN. Number of domains Total number of domains. WWN WWN of the switch. Principal indicates a principal switch, and Local indicates a local switch. Related commands domain configure enable display fc ess Use display fc ess to display the Exchange Switch Support (ESS) negotiation result, including the following information: • The capabilities of the local switch after the ESS negotiation. • The capabilities of the remote switch after the ESS negotiation. Syntax display fc ess [ vsan vsan-id ] Views Any view Predefined user roles network-admin network-operator Parameters vsan vsan-id: Specifies a VSAN by its ID in the range of 1 to 3839. If you do not specify a VSAN, this command displays the ESS negotiation results of all VSANs. Examples # Display the ESS negotiation result in VSAN 2. display fc ess vsan 2 ESS info of VSAN 2: Domain: 210 Directory Server Capability: Accept large name server objects: Yes Accept small name server objects: No Accept large + FC-4 Features name server objects: No

Accept small + FC-4 Features name server objects: No

Support receiving ACCept with 0 length: Yes Fabric Controller Capability: Support receiving the SW_RSCN Request: Yes Fabric Configuration Server Capability: Support basic configuration services: Yes Support platform configuration services: No Support topology discovery configuration services: Yes Support enhanced configuration services: Yes Enhanced Zone Server Capability: Support enhanced zoning management: Yes Table 16 Command output Field Description Domain Domain ID of the switch. Directory Server Capability List of directory server capabilities. Accept large name server objects Indicates whether the switch supports accepting large name server objects. A large name server object contains the symbolic name of the N_Port and the symbolic name of the node in addition to the information of a small name server object. Accept small name server objects Indicates whether the switch supports accepting small name server objects. A small name server object contains only the basic information, and does not contain the symbolic name of the N_Port, the symbolic name of the node, or information about supported FC-4 features. Accept large + FC-4 Features name server objects Indicates whether the switch supports accepting large + FC-4-feature name server objects. Accept small + FC-4 Features name server objects Indicates whether the switch supports accepting small + FC-4-feature name server objects. Support receiving ACCept with 0 length Indicates whether the switch supports accepting an ACCEPT reply whose payload is 0. Fabric Controller Capability List of fabric controller capabilities. Support receiving the SW_RSCN Request Indicates whether the switch supports accepting an SW_RSCN (Registered State Change Notification) request. display fc login Use display fc login to display the node login information of the specified VSANs. Syntax display fc login [ vsan vsan-id ] [ count ] Views Any view

Predefined user roles

network-admin network-operator Parameters vsan vsan-id: Specifies a VSAN by its ID in the range of 1 to 3839. If you do not specify a VSAN, this command displays the node login information of all VSANs. count: Displays the total number of logged-in nodes. Examples # Display the node login information of VSAN 1. display fc login vsan 1 Interface VSAN FCID Node WWN Port WWN Fc1/0/1 1 0x010000 21:01:00:1b:32:a0:fa:18 21:01:00:1b:32:a0:fa:17 # Display the number of logged-in nodes for VSAN 1. display fc login vsan 1 count Total entries: 1 # Display the number of logged-in nodes for each VSAN and the total number of logged-in nodes. display fc login count VSAN Entries 1 1 2 1 Total entries: 2 Table 17 Command output Field Description Interface Interface on the switch connected to the node. VSAN VSAN ID. FCID FC address assigned by the switch to the node. Port WWN WWN of the port connecting the node to the switch. Entries Number of logged-in nodes for a VSAN. Total Entries Total number of logged-in nodes. display fc name-service database Use display fc name-service database to display the name server database. Syntax display fc name-service database [ vsan vsan-id [ fcid fcid ] ] [ verbose ] display fc name-service database [ vsan vsan-id ] count Views Any view

Predefined user roles

network-admin network-operator Parameters vsan vsan-id: Specifies a VSAN by its ID in the range of 1 to 3839. If you do not specify a VSAN, this command displays the name server database information of all VSANs. fcid fcid: Specifies an FC address in the range of 0x010000 to 0xEFFFFF (hexadecimal). If you do not specify an FC address, this command displays the name server database entries of all FC addresses. verbose: Displays detailed information about the name service database. If you do not specify this keyword, the command displays brief information about the name server database. count: Displays the number of name service entries. Examples # Display brief information about the name server database in VSAN 1. display fc name-service database vsan 1 VSAN 1: FCID Type PWWN(vendor) FC4-type:feature 0x030001 0x01(N) 20:00:00:05:30:00:25:a3 SCSI-FCP 0x030200 0x01(N) 20:00:00:49:c9:28:c7:01 NPV # Display the number of name service entries for VSAN 1. display fc name-service database vsan 1 count Total entries: 2 Table 18 Command output Field Description FCID FC address of the N_Port. Type Link type of the N_Port, which can be N representing point-to-point. PWWN(vendor) WWN of the N_Port (name of vendor). FC4-type:feature FC4 type feature entry (when this command displays brief information, up to two FC4 type feature entries are displayed): • FC4 type—Includes SCSI-FCP, LLC/SNAP, SW_ILS, SNMP, GS3, VI, and NPV. • Feature—Includes supporting Initiator, Target, or Initiator/Target. # Display detailed information about the name service database. display fc name-service database verbose VSAN:1 FCID:0x030001 Port-WWN(vendor): 20:00:00:05:30:00:25:a3 Node-WWN: 20:00:00:05:30:00:25:9e Class: 2,3 Node-IP-addr: 192.168.0.52 FC4-types(FC4_features): SCSI-FCP Symbolic-port-name: Symbolic-node-name: Port-type: 0x01(N)

--- Total 2 entries ---

Table 19 Command output Field Description FCID FC address of the N_Port. Type Port type registered by the node with the switch: • 0x00(Unidentified)—No port type is registered. • 0x01(N)—N_Port, which directly connects to the fabric. • 0x02(NL)—NL_Port, which connects to the fabric through an arbitrated loop. • 0x03(F/NL)—F_Port or NL_Port. • 0x7f(Nx)—N_Port, NL_Port, or F_Port, or NL_Port. • 0x81(F)—F_Port, which connects to an N_Port. • 0x82(FL)—FL_Port, which connects to an NL_Port. • 0x84(E)—E_Port, which connects to an E_Port or B_Port. • 0x85(B)—B_Port. The ports on a bridge that connect two E_Ports are called B_Ports. • 0xXX(Unknown)—Port types other than the preceding ones. NOTE: Typically, only N_Ports and NL_Ports will be registered by a node. Port-WWN(vendor) WWN of the N_Port (name of vendor). Node-WWN WWN of the node. Class Class of service. Node-IP-addr IP address of the node. FC4-types(FC4 features) FC4 type (feature) entries: • FC4 type—Includes SCSI-FCP, LLC/SNAP, SW_ILS, SNMP, GS3, VI, and NPV. • Feature—Includes supporting Initiator, Target, or Initiator/Target. Symbolic-port-name Symbolic name, which is used for describing an N_Port. For an NP_Port on an HP NPV switch, it is in the form of system-name:port-name.

Symbolic name, which is used for describing a node. For an HP NPV

switch, it is the system-name. Port-type Link type of the N_Port, which can be N representing point-to-point. Fabric-port-WWN WWN of the F_Port. Hard-addr Hardware address of the N_Port. Total entries Number of entries in the VSAN. display fc scr-table Use display fc scr-table to display the State Change Registration (SCR) list of N_Ports. Syntax display fc scr-table [ vsan vsan-id ] [ count ] Views Any view Predefined user roles network-admin network-operator Parameters vsan vsan-id: Displays the SCR list in the specified VSAN. The vsan-id argument is in the range of 1 to 3839. If you do not specify a VSAN, this command displays the SCR lists of all VSANs. count: Displays the number of SCR entries. Examples # Display the SCR list. display fc scr-table SCR table for VSAN 1: FCID REGISTERED FOR 0x1b0300 fabric detected rscns 0x010121 nx_port detected rscns --- Total 2 entries --- # Display the number of SCR entries. display fc scr-table vsan 1 count Total entries: 2 Table 20 Command output Field Description SCR table for VSAN SCR list in a VSAN. FCID FC address of the N_Port.

Type of Registered State Change Notification (RSCN) messages:

• fabric detected rscns—Accepts all RSCN messages sent by the switches in the fabric. • nx_port detected rscns—Accepts all RSCN messages sent by N_Ports. • full detected rscns—Accepts all RSCN messages. Total entries Number of SCR entries in the VSAN. display fc switch-wwn Use display fc switch-wwn to display the WWN of the local switch. Syntax display fc switch-wwn Views Any view Predefined user roles network-admin network-operator Examples # Display the WWN of the local switch. display fc switch-wwn Switch WWN is 10:00:00:0d:ec:ff:a3:25 display fc timer Use display fc timer to display fabric timers. Syntax display fc timer [ distributed-services | error-detect | resource-allocation ] [ vsan vsan-id ] Views Any view Predefined user roles network-admin network-operator Parameters distributed-services: Displays the distributed service timeout period, in milliseconds. error-detect: Displays the error detection timeout period, in milliseconds. resource-allocation: Displays the resource allocation timeout period, in milliseconds. vsan vsan-id: Specifies a VSAN by its ID in the range of 1 to 3839. If you do not specify a VSAN, this command displays global fabric timer information.

If you do not specify the distributed-services, error-detect, or resource-allocation keyword, this

command displays all the fabric timers. Examples # Display all the fabric timers for VSAN 1. display fc timer vsan 1 Timer of VSAN 1: Distributed-services timer: 5000 ms Error-detect timer: 2000 ms Resource-allocation timer: 10000 ms domain auto-reconfigure enable Use domain auto-reconfigure enable to enable automatic reconfiguration in a VSAN. Use undo domain auto-reconfigure enable to disable automatic reconfiguration in a VSAN . Syntax domain auto-reconfigure enable undo domain auto-reconfigure enable Default Automatic reconfiguration is disabled in each VSAN. Views VSAN view Predefined user roles network-admin Usage guidelines This command takes effect only when the fabric configuration function is enabled. A fabric reconfiguration triggers a principal switch selection phase. A disruptive reconfiguration is automatically performed if the domain ID lists overlap when two fabrics are merged. A nondisruptive reconfiguration is automatically performed when one of the following conditions exists: • When two fabrics are merged, the principal switch information of the two fabrics is different, and the domain ID lists are not empty and do not overlap. • A principal link in a fabric goes down. Examples # Enable the automatic reconfiguration function in VSAN 1. system-view [Sysname] vsan 1 [Sysname-vsan1] domain auto-reconfigure enable Related commands domain configure enable

domain configure enable

Use domain configure enable to enable the fabric configuration function for the switch in a VSAN. Use undo domain configure enable to disable the fabric configuration function for the switch in a VSAN. Syntax domain configure enable undo domain configure enable Default The fabric configuration function is enabled in a VSAN. Views VSAN view Predefined user roles network-admin Usage guidelines After you enable the fabric configuration function on FC switches, the switches exchange messages to select the principal switch. Then, the principal switch dynamically assigns domain IDs to all switches in the fabric. After you disable the fabric configuration function on FC switches, the switches will not select a principal switch and cannot obtain domain IDs dynamically. You must configure a unique domain ID for each switch. • To dynamically build a fabric, you must enable the fabric configuration function on switches. • To statically build a fabric, you must disable the fabric configuration function on switches and manually configure domain IDs for the switches. Examples # Enable the fabric configuration function for the switch in VSAN 1. system-view [Sysname] vsan 1 [Sysname-vsan1] domain configure enable domain restart Use domain restart to manually initiate a fabric reconfiguration in a VSAN. Syntax domain restart [ disruptive ] Views VSAN view Predefined user roles network-admin Parameters disruptive: Initiates a disruptive reconfiguration. If you do not specify this keyword, the command initiates a nondisruptive reconfiguration.

This command takes effect only when the fabric configuration function is enabled.

A fabric reconfiguration triggers a principal switch selection phase. A fabric reconfiguration can be disruptive or nondisruptive. A fabric reconfiguration can be disruptive or nondisruptive. • Disruptive reconfiguration—Floods Reconfigure Fabric (RCF) frames throughout the fabric and notifies all switches to perform a disruptive reconfiguration. During the reconfiguration procedure, each switch clears all data and performs renegotiation, and data transmission in the fabric is disrupted. • Nondisruptive reconfiguration—Floods Build Fabric (BF) frames throughout the fabric and notifies all switches to perform a nondisruptive reconfiguration. During the reconfiguration procedure, each switch tries to save the last running data for its domain ID to remain unchanged. Thus, data transmission in the fabric is not disrupted. For fabric settings that do not take effect immediately (for example, switch priority), you can perform a disruptive reconfiguration to make them take effect. Examples # Manually initiate a disruptive reconfiguration in VSAN 1. system-view [Sysname] vsan 1 [Sysname-vsan1] domain restart disruptive The command may cause traffic interruption. Continue? [Y/N]:y Related commands domain configure enable domain-id Use domain-id to configure a domain ID for the switch in a VSAN. Use undo domain-id to restore the default. Syntax domain-id domain-id { preferred | static } undo domain-id Default The domain ID is 0 preferred in a VSAN. Views VSAN view Predefined user roles network-admin Parameters domain-id: Specifies a domain ID in the range of 1 to 239. preferred: Specifies the domain ID as preferred.

static: Specifies the domain ID as static.

Usage guidelines The upper-layer protocol identifies only the WWN, but FC switches use domain IDs to route and forward packets. Domain IDs are assigned on a per-VSAN basis and have a default value of 0, which cannot distinguish switches. Therefore, you must statically configure or dynamically assign domain IDs for FC switches. In the static domain ID assignment method, the ID type configuration does not affect the assignment result. In the dynamic domain ID assignment method, the principal switch assigns a domain ID to each switch in the fabric. If a member switch fails to get a preferred domain ID from the principal switch, it accepts any other domain ID assigned by the principal switch. If the member switch fails to get a static domain ID, it does not accept any other domain ID and isolates the upstream principal link. HP recommends that you configure domain IDs of the same type for all switches in a VSAN. Examples # Configure static domain ID 55 in VSAN 1. system-view [Sysname] vsan 1 [Sysname-vsan1] domain-id 55 static Non-disruptive reconfiguration or isolating the switch may be performed. Continue? [Y/N]: fabric-name Use fabric-name to configure a fabric name in a VSAN. Use undo fabric-name to restore the default. Syntax fabric-name name undo fabric-name Default The fabric name is the WWN of the switch. Views VSAN view Predefined user roles network-admin Parameters name: Specifies a fabric name, in the format of xx:xx:xx:xx:xx:xx:xx:xx, where x is a hexadecimal number. Usage guidelines An FC switch supports assigning a fabric name to each VSAN, in the same format as the WWN (a 64-bit address).

You need to configure fabric names only when you build a fabric statically. You must configure the same

fabric name on all switches in a VSAN. In a dynamically built fabric, each VSAN uses the WWN of the principal switch as the fabric name. Examples # Configure a fabric name of 10:11:12:13:14:15:16:17 in VSAN 1. system-view [Sysname] vsan 1 [Sysname-vsan1] fabric-name 10:11:12:13:14:15:16:17 fc domain rcf-reject Use fc domain rcf-reject to configure an interface to reject the ReConfigure Fabric (RCF) requests received in a VSAN. Use undo fc domain rcf-reject to restore the default. Syntax fc domain rcf-reject vsan vsan-id undo fc domain rcf-reject vsan vsan-id Default An interface does not reject the received RCF requests. Views FC interface view, FC aggregate interface view, VFC interface view Predefined user roles network-admin Parameters vsan vsan-id: Specifies a VSAN by its ID in the range of 1 to 3839. Usage guidelines In a stable fabric, to avoid unnecessary disruptive reconfigurations, you can configure an interface to reject the RCF requests received in a VSAN. With this feature, the switch replies with a reject message and isolates the interface that receives an RCF request. Examples # Configure interface FC 1/0/1 to reject the RCF requests received in VSAN 1. system-view [Sysname] interface fc 1/0/1 [Sysname-Fc1/0/1] fc domain rcf-reject vsan 1 # Configure interface VFC 1 to reject the RCF requests received in VSAN 1. system-view [Sysname] interface vfc 1 [Sysname-Vfc1] fc domain rcf-reject vsan 1 fc name-service auto-discovery Use fc name-service auto-discovery to enable SCSI-FCP information autodiscovery.

Use undo fc name-service auto-discovery to disable SCSI-FCP information autodiscovery.

Syntax fc name-service auto-discovery undo fc name-service auto-discovery Default Auto discovery of SCSI-FCP information is enabled. Views VSAN view Predefined user roles network-admin Usage guidelines In some situations, for example, when a node logs out and then logs back in, the node does not register SCSI-FCP support. Therefore, the node does not have a Feature value. This might cause communication failure between the node and other nodes. This feature enables the switch to automatically obtain SCSI-FCP support and the Feature value by sending a PRLI packet to the node that is logging in. Then, the switch stores the SCSI-FCP information in the name service database. NOTE: After this feature is enabled, nodes with older-model HBAs might not actively register name service information with the switch. Examples # Enable SCSI-FCP information autodiscovery in VSAN 2. system-view [Sysname] vsan 2 [Sysname-vsan2] fc name-server auto-discovery fc timer distributed-services Use fc timer distributed-services to specify the global distributed service timeout period. Use undo fc timer distributed-services to restore the default. Syntax fc timer distributed-services value undo fc timer distributed-services Default The global distributed service timeout period is 5000 milliseconds. Views System view Predefined user roles network-admin

value: Specifies the distributed service timeout period in the range of 5000 to 10000 milliseconds.

Usage guidelines The distributed service timeout period can be configured in system view or VSAN view. • The configuration in system view takes effect on all VSANs. The configuration in VSAN view takes effect only on the current VSAN. • If you configure the distributed service timeout period both globally and for a VSAN, the configuration for the VSAN is given priority. Examples # Set the global distributed service timeout period to 6000 milliseconds. system-view [Sysname] fc timer distributed-services 6000 Related commands timer distributed-services fc timer error-detect Use fc timer error-detect to specify the global error detection timeout period. Use undo fc timer error-detect to restore the default. Syntax fc timer error-detect value undo fc timer error-detect Default The global error detection timeout period is 2000 milliseconds. Views System view Predefined user roles network-admin Parameters value: Specifies the error detection timeout period in the range of 1000 to 10000 milliseconds. Usage guidelines The error detection timeout period can be configured in system view or VSAN view. • The configuration in system view takes effect on all VSANs. The configuration in VSAN view takes effect only on the current VSAN. • If you configure the error detection timeout period both globally and for a VSAN, the configuration for the VSAN is given priority. Examples # Set the global error detection timeout period to 6000 milliseconds. system-view [Sysname] fc timer error-detect 6000

fc timer resource-allocation

Use fc timer resource-allocation to specify the global resource allocation timeout period. Use undo fc timer resource-allocation to restore the default. Syntax fc timer resource-allocation value undo fc timer resource-allocation Default The global resource allocation timeout period is 10000 milliseconds. Views System view Predefined user roles network-admin Parameters value: Specifies the resource allocation timeout period in the range of 5000 to 10000 milliseconds. Usage guidelines The resource allocation timeout period can be configured in system view or VSAN view. • The configuration in system view takes effect on all VSANs. The configuration in VSAN view takes effect only on the current VSAN. • If you configure the resource allocation timeout period both globally and for a VSAN, the configuration for the VSAN is given priority. Examples # Set the global resource allocation timeout period to 6000 milliseconds. system-view [Sysname] fc timer resource-allocation 6000 Related commands timer resource-allocation fc wwn default-fc4-type Use fc wwn default-fc4-type to configure the default FC4 information for a node. Use undo fc wwn default-fc4-type to delete the default FC4 information of a node. Syntax fc wwn wwn-value default-fc4-type { type-value feature feature-map | scsi-fcp feature { feature-map | both | initiator | target } } undo fc wwn wwn-value default-fc4-type { type-value | scsi-fcp }

No default FC4 information is configured.

Views System view Predefined user roles network-admin Parameters wwn-value: Specifies an N_Port by its WWN in the format of xx:xx:xx:xx:xx:xx:xx:xx (hexadecimal). type-value: Specifies a supported FC4-Type by its value in the range of 0 to 255. The FC4-Type field is 256 bits, each of which represents an FC4-Type. If a bit is set to 1, the FC4-Type that the bit represents is supported. Only one bit can be set to 1 at the same time. scsi-fcp: Specifies the supported FC4-Type as SCSI-FCP, which has a type-value of 8. feature feature-map: Specifies the Feature value for the supported FC4-Type. The value range for feature-map is 0 to 15. The Feature field is 4 bits, each of which represents a Feature. If a bit is set to 1, the Feature that the bit represents is supported. Multiple bits can be set to 1 at the same time. For example, if the value is set to 15, the node supports four Features of the FC4-Type. If the value is set to 0, the node supports none of the four Features. When you specify supported FC4-Type as SCSI-FCP, you can configure the following keywords: • initiator: Specifies support for the initiator Feature, which has a feature-map of 2. • target: Specifies support for the target Feature, which has a feature-map of 1. • both: Specifies support for both initiator and target Features, which has a feature-map of 3. Usage guidelines The switch records the default FC4 information in the name service database for a node when the following conditions exist: • The node does not register FC4 information. • The switch fails to obtain SCSI-FCP information from the node. The switch replaces the default FC4 information with the registered FC4 information or obtained SCSI-FCP information when one of the following events occurs: • A node registers FC4 information. • The switch obtains the SCSI-FCP information. This command can configure only one combination of FC4-Type and Feature at a time. Examples # Configure the default FC4 information for the node with WWN 00:00:00:11:22:33:44:55. system-view [Sysname] fc wwn 00:00:00:11:22:33:44:55 default-fc4-type scsi-fcp feature target [Sysname] fc wwn 00:00:00:11:22:33:44:55 default-fc4-type 9 feature 7 priority Use priority to configure the switch priority in a VSAN. Use undo priority to restore the default.

The switch priority is 128 in a VSAN.

Views VSAN view Predefined user roles network-admin Parameters value: Specifies the switch priority in the range of 1 to 254. Usage guidelines The priority value for FC switches is in the range of 1 to 254. The smaller the value, the higher the priority. The FC switch with the highest priority will become the principal switch. The priority is configured on a per-VSAN basis, and one FC switch can have different priorities in different VSANs. The priority configuration for the switch does not take effect until a disruptive reconfiguration is performed by using the domain restart disruptive command. Examples # Configure the switch priority as 64 in VSAN 1. system-view [Sysname] vsan 1 [Sysname-vsan1] priority 64 Related commands domain restart rscn aggregation enable Use rscn aggregation enable to enable RSCN aggregation. Use undo rscn aggregation enable to disable RSCN aggregation. Syntax rscn aggregation enable undo rscn aggregation enable Default RSCN aggregation is disabled. Views VSAN view Predefined user roles network-admin

For multiple change events occurring within the RSCN aggregation timer interval, RSCN aggregation

places the FC addressees of multiple nodes with changes into a single RSCN. This reduces the number of RSCNs sent to the concerned registered nodes. HP recommends that you enable RSCN aggregation and set the same timer value on all switches in a VSAN. Examples # Enable RSCN aggregation in VSAN 1. system-view [Sysname] vsan 1 [Sysname-vsan1] rscn aggregation enable Related commands rscn aggregation timer rscn aggregation timer Use rscn aggregation timer to set the RSCN aggregation timer. Use undo rscn aggregation timer to restore the default. Syntax rscn aggregation timer time undo rscn aggregation timer Default The RSCN aggregation timer is 2000 milliseconds. Views VSAN view Predefined user roles network-admin Parameters time: Specifies a value for the RSCN aggregation timer, in the range of 100 to 2000 milliseconds. Usage guidelines The RSCN aggregation timer takes effect only when RSCN aggregation is enabled. HP recommends that you enable RSCN aggregation and set the same timer value on all switches in a VSAN. Examples # Set the RSCN aggregation timer of VSAN 1 to 1500 milliseconds. system-view [Sysname] vsan 1 [Sysname-vsan1] rscn aggregation timer 1500 Related commands rscn aggregation enable

snmp-agent trap enable fc-fabric

Use snmp-agent trap enable fc-fabric to enable SNMP notifications for the fabric module. Use undo snmp-agent trap enable fc-fabric to disable SNMP notifications for the fabric module. Syntax snmp-agent trap enable fc-fabric [ domain-id-change | fabric-change ] * undo snmp-agent trap enable fc-fabric [ domain-id-change | fabric-change ] * Default All SNMP notifications for the fabric module are disabled. Views System view Predefined user roles network-admin Parameters domain-id-change: Specifies domain ID changes. fabric-change: Specifies fabric changes. Usage guidelines If you do not specify any keywords, this command enables all SNMP notifications for the fabric module. After you enable SNMP notifications for domain ID changes, the switch generates a notification when its domain ID changes in a VSAN. The notification includes the VSAN ID, the switch WWN, and the new domain ID. After you enable SNMP notifications for fabric changes, the switch generates a notification when it sends or receives a BF or RCF frame for fabric reconfiguration. The notification includes the VSAN ID for fabric reconfiguration. Generated notifications are sent to the SNMP module. For more information about SNMP notifications, see Network Management and Monitoring Configuration Guide. Examples # Enable SNMP notifications for domain ID changes. system-view [Sysname] snmp-agent trap enable fc-fabric domain-id-change # Enable SNMP notifications for fabric changes. system-view [Sysname] snmp-agent trap enable fc-fabric fabric-change snmp-agent trap enable fc-name-service Use snmp-agent trap enable fc-name-service to enable SNMP notifications for the name service module. Use undo snmp-agent trap enable fc-name-service to disable SNMP notifications for the name service module.

snmp-agent trap enable fc-name-service [ login| logout ] *

undo snmp-agent trap enable fc-name-service [ login| logout ] * Default All SNMP notifications for the name service module are disabled. Views System view Predefined user roles network-admin Parameters login: Specifies node login. logout: Specifies node logout. Usage guidelines If you do not specify any keywords, this command enables all SNMP notifications for the name service module. After you enable SNMP notifications for node login or logout, the switch generates a notification when a node registers or deregisters its name service information with the switch. The notification includes the VSAN ID, the switch WWN, and the WWN of the N_Port. Generated notifications are sent to the SNMP module. For more information about SNMP notifications, see Network Management and Monitoring Configuration Guide. Examples # Enable SNMP notifications for node login. system-view [Sysname] snmp-agent trap enable fc-name-service login timer distributed-services Use timer distributed-services to specify the distributed service timeout period for a VSAN. Use undo timer distributed-services to restore the default. Syntax timer distributed-services value undo timer distributed-services Default The distributed service timeout period is 5000 milliseconds. Views VSAN view Predefined user roles network-admin

value: Specifies the distributed service timeout period in the range of 5000 to 10000 milliseconds.

Usage guidelines The distributed service timeout period can be configured in system view or VSAN view. • The configuration in system view takes effect on all VSANs. The configuration in VSAN view takes effect only on the current VSAN. • If you configure the distributed service timeout period both globally and for a VSAN, the configuration for the VSAN is given priority. Examples # Set the distributed service timeout period to 6000 milliseconds for VSAN 1. system-view [Sysname] vsan 1 [Sysname-vsan1] timer distributed-services 6000 Related commands fc timer distributed-services timer error-detect Use timer error-detect to specify the error detection timeout period for a VSAN. Use undo timer error-detect to restore the default. Syntax timer error-detect value undo timer error-detect Default The error detection timeout period is 2000 milliseconds. Views VSAN view Predefined user roles network-admin Parameters value: Specifies the error detection timeout period in the range of 1000 to 10000 milliseconds. Usage guidelines The error detection timeout period can be configured in system view or VSAN view. • The configuration in system view takes effect on all VSANs. The configuration in VSAN view takes effect only on the current VSAN. • If you configure the error detection timeout period both globally and for a VSAN, the configuration for the VSAN is given priority. Examples # Set the error detection timeout period to 6000 milliseconds for VSAN 1. system-view

[Sysname] vsan 1

[Sysname-vsan1] timer error-detect 6000 Related commands fc timer error-detect timer resource-allocation Use timer resource-allocation to specify the resource allocation timeout period for a VSAN. Use undo timer resource-allocation to restore the default. Syntax timer resource-allocation value undo timer resource-allocation Default The resource allocation timeout period is 10000 milliseconds. Views VSAN view Predefined user roles network-admin Parameters value: Specifies the resource allocation timeout period in the range of 5000 to 10000 milliseconds. Usage guidelines The resource allocation timeout period can be configured in system view or VSAN view. • The configuration in system view takes effect on all VSANs. The configuration in VSAN view takes effect only on the current VSAN. • If you configure the resource allocation timeout period both globally and for a VSAN, the configuration for the VSAN is given priority. Examples # Set the resource allocation timeout period to 6000 milliseconds for VSAN 1. system-view [Sysname] vsan 1 [Sysname-vsan1] timer resource-allocation 6000 Related commands fc timer resource-allocation wwn area-port-id Use wwn area-port-id to bind the WWN of an N_Port to an FC address in a VSAN. Use undo wwn area-port-id to remove a WWN-to-FC address binding. Syntax wwn wwn-value area-port-id area-port-id-value

undo wwn wwn-value area-port-id

Default The WWN of an N_Port is not bound to any FC address. Views VSAN view Predefined user roles network-admin Parameters wwn-value: Specifies the WWN of the N_Port, in the format of xx:xx:xx:xx:xx:xx:xx:xx, where x is a hexadecimal number. area-port-id-value: Specifies the area ID and port ID in the format of xxxx, where x is a hexadecimal number. The first two digits indicate the area ID, and the last two digits indicate the port ID. Usage guidelines The switch assigns the FC address bound to an N_Port when the N_Port requests an FC address. However, if the N_Port has been assigned another FC address or the FC address has been assigned to another N_Port, the binding fails. The N_Port here indicates an N_Port on a node or an NP_Port on an NPV switch. The WWN of an N_Port can be bound to only one FC address, and vice versa. Examples # In VSAN 1, bind the N_Port (WWN is 33:e8:00:05:30:00:16:df) to an FC address (area ID is ab and port ID is 12). system-view [Sysname] vsan 1 [Sysname-vsan1] wwn 33:e8:00:05:30:00:16:df area-port-id ab12 FC routing and forwarding commands display fc exchange Use display fc exchange to display the FC exchange entries. Syntax display fc exchange { link | protocol } [ slot slot-number ] display fc exchange link verbose [ slot slot-number [ exid exid ] ] Views Any view Predefined user roles network-admin network-operator

link: Displays link exchange entries.

protocol: Displays protocol exchange entries. verbose: Displays detailed information about link exchange entries. exid exid: Displays link exchange entries for an exchange ID in the range of 0 to 65534. If you do not specify an exchange ID, this command displays all link exchange entries. slot slot-number: Specifies an IRF member device by its member ID (slot number). If you do not specify an IRF member device, this command displays exchange entries for the master device. Usage guidelines The exchange is a basic concept of FC. All data frames and control frames are transmitted based on the exchange. An exchange indicates one data exchange between communication entities and can contain multiple bidirectional packet exchanges. An exchange pair (initiating exchange and responding exchange) must be created for each data exchange. Service classes that provide reliable transmission services (classes 1, 2, and 6) perform packet acknowledgment, error detection, and packet retransmission based on the exchange pair. Exchanges include the following categories: • Protocol exchange—Created only at the server end based on the protocol number and VSAN ID and used to monitor connection establishment. • Link exchange—Created at both ends based on the exchange ID and used for packet exchange. Examples # Display the protocol exchange entries. display fc exchange protocol slot 1 Local_ID:EXID Remote_ID:EXID State Slot Protocol 0x000000:65535 0x000000:65535 LISTEN 1 6 # Display the link exchange entries. display fc exchange link slot 2 Local_ID:EXID Remote_ID:EXID State Slot Protocol 0x060501:1024 0x010001:1025 ESTABLISHED 2 8 # Display detailed information about the link exchange entries. display fc exchange link verbose slot 1 slot: 1 protocol: 8 connection info: Local = 0x090801:1155 , Remote = 0x050001:1089 PCB flags: 0x2 FC Class: FC_CLASS_F connection state: ESTABLISHED VSAN ID: 25 Table 21 Command output Field Description Local_ID:EXID/Local FC address and exchange ID of the local end. This field is ignored for a protocol exchange.

FC address and exchange ID of the peer end.

This field is ignored for a protocol exchange. State/connection state Connection state of the FC exchange: • PREPARE—The protocol exchange is successfully bound, or the link exchange is waiting for the response packet. • LISTEN—The protocol exchange is monitoring the connection. • ESTABLISHED—The connection has been established. • ABTS—An ABTS was sent due to a connection timeout or error, and the ABTS ACK is being expected. • BA_ACC—An ABTS was received, an BA_ACC is replied, and an ACC ACK is being expected. • ABTS_ACK—An ABTS ACK was received, and a BA_ACC is being expected. • CLOSED—The connection is closed. Slot/slot IRF member device where the FC exchange is created. Protocol/protocol FC protocol number. PCB flags FC exchange state flags: • 0x1—The value 0 indicates the sending end, and 1 indicates the replying end. • 0x2—The value 0 means there is no initiative, and 1 means there is initiative. • 0x4—The value 1 indicates the first packet of the exchange. • 0x8—The value 1 indicates that the exchange is waiting to be aged. FC Class FC connection service level (FC_CLASS_3 requires no ACK): • FC_CLASS_1. • FC_CLASS_2. • FC_CLASS_3. • FC_CLASS_F. • FC_CLASS_6. display fc fib Use display fc fib to display the FC FIB entries. Syntax display fc fib [ fcid [ mask-length ] ] vsan vsan-id Views Any view Predefined user roles network-admin network-operator

fcid: Specifies a destination FC address in the range of 0x000000 to 0xFFFFFF (hexadecimal).

mask-length: Specifies a mask length for the destination address, in the range of 0 to 24. vsan vsan-id: Specifies a VSAN by its ID in the range of 1 to 4095. Usage guidelines The device looks up the VSAN ID and FC address in the FC FIB for the outgoing interface. If you specify both the fcid and mask-length arguments, this command displays FC FIB entries for the specified FC address and mask length. If you specify the fcid argument but not the mask-length argument, this command displays FC FIB entries for the specified FC address according to the longest matching rule. If you do not specify the fcid argument or the mask-length argument, this command displays all FC FIB entries. Examples # Display all the FC FIB entries in VSAN 18. display fc fib vsan 18 FC FIB information in VSAN 18: Destination count: 6 FIB entry count: 7 Destination/Mask Interface 0x030100/16 Fc1/0/1 0x030100/16 Fc1/0/2 0x030100/24 Fc1/0/3 0xfffc01/24 InLoop0 0xfffffa/24 InLoop0 0xfffffc/24 InLoop0 0xfffffd/24 InLoop0 # Display the FC FIB entries for the specified FC address according to the longest matching rule. display fc fib 030100 vsan 18 FC FIB information in VSAN 18: Destination count: 1 FIB entry count: 1 Destination/Mask Interface 0x030100/24 Fc1/0/3 # Display the FC FIB entries for the specified FC address and mask length. display fc fib 030100 16 vsan 18 FC FIB information in VSAN 18: Destination count: 1 FIB entry count: 2 Destination/Mask Interface 0x030100/16 Fc1/0/1 0x030100/16 Fc1/0/2

Table 22 Command output

Field Description Destination count Number of destination addresses. FIB entry count Number of FIB entries, including equal-cost routes. Destination/Mask Destination address/mask length. Interface Outgoing interface. display fc routing-table Use display fc routing-table to display the FC routing table. Syntax display fc routing-table [ vsan vsan-id ] [ statistics | verbose ] display fc routing-table vsan vsan-id fcid [ mask | mask-length ] [ verbose ] Views Any view Predefined user roles network-admin network-operator Parameters vsan vsan-id: Specifies a VSAN by its ID in the range of 1 to 4095. If you do not specify a VSAN, this command displays routing information of all VSANs. fcid: Specifies the destination FC address for static FC routes, in the range of 0x010000 to 0xFFFFFF (hexadecimal). mask: Specifies a hexadecimal mask of the FC address. This argument is used together with the fcid argument. The value of this argument can be 0xFF0000, 0xFFFF00, or 0xFFFFFF. If you do not specify a hexadecimal mask, this command displays the routing information for the FC address fcid with masks 0xFF0000, 0xFFFF00, and 0xFFFFFF. mask-length: Specifies a decimal mask of the FC address. This argument is used together with the fcid argument. The value of this argument can be 8, 16, or 24. If you do not specify a decimal mask, this command displays the routing information for the FC address fcid with masks 8, 16, and 24. statistics: Displays the statistics for the FC routing table. verbose: Displays detailed information about the FC routing table. Usage guidelines The routing table stores routes discovered by various routing protocols. You can use this command to display brief information, detailed information, and statistics about the routing table. If you do not specify the statistics or verbose keyword, this command displays brief information about the FC routing table. The brief information contains information about only active routes. The detailed information contains information about both active and inactive routes.

# Display brief information about all the routes in VSAN 5.

display fc routing-table vsan 5 Routing Table: VSAN 5 Destinations : 5 Routes : 8 Destination/mask Protocol Preference Cost Interface 0x040000/8 FSPF 20 100 Vfc10 0x040000/8 FSPF 20 100 Vfc20 0x040000/8 FSPF 20 100 Vfc30 0x040000/8 FSPF 20 100 Vfc40 0xfffc01/24 DIRECT 0 0 InLoop0 0xfffffa/24 DIRECT 0 0 InLoop0 0xfffffc/24 DIRECT 0 0 InLoop0 0xfffffd/24 DIRECT 0 0 InLoop0 # Display detailed information about all the routes in VSAN 5. display fc routing-table vsan 5 verbose Routing Table: VSAN 5 Destinations : 5 Routes : 5 Destination/mask: 0x120000/8 Protocol: STATIC Preference: 10 Cost: 0 Interface: Fc1/0/1 State: Active Age: 0h21m36s Destination/mask: 0xfffc01/24 Protocol: DIRECT Preference: 0 Cost: 0 Interface: InLoop0 State: Active Age: 0h21m36s Destination/mask: 0xfffffa/24 Protocol: DIRECT Preference: 0 Cost: 0 Interface: InLoop0 State: Active Age: 0h21m36s Destination/mask: 0xfffffc/24 Protocol: DIRECT Preference: 0 Cost: 0 Interface: InLoop0

Table 23 Command output

Field Description VSAN VSAN number. Destination/mask FC address/mask. Protocol Protocol type: • DIRECT—Direct routes. • STATIC—Static routes. • FSPF—FSPF routes. Preference Route preference. Cost Route cost. Interface Outgoing interface. State Route state: Active or Inactive. Age Lifetime of the route in the routing table, in the format of XXhXXmXXs. # Display the statistics for all the routes in VSAN 5. display fc routing-table vsan 5 statistics Routing Table: VSAN 5 Protocol route active added deleted DIRECT 4 4 4 0 STATIC 1 1 1 0 FSPF 0 0 0 0 Total 5 5 5 0 Table 24 Command output Field Description VSAN VSAN number. Protocol Protocol type: • DIRECT—Direct routes. • STATIC—Static routes. • FSPF—FSPF routes. route Number of routes of the specified protocol type. active Number of active routes of the specified protocol type. added Number of added routes of the specified protocol type.

Number of deleted routes of the specified protocol type.

Total Total number of routes. Related commands fc route-static display fspf graceful-restart Use display fspf graceful-restart to display FSPF GR status information. Syntax display fspf graceful-restart [ vsan vsan-id ] Views Any view Predefined user roles network-admin network-operator Parameters vsan vsan-id: Specifies a VSAN by its ID in the range of 1 to 3839. If you do not specify a VSAN, this command displays FSPF GR status information for all VSANs. Usage guidelines The SPF GR status information includes the following details: • Whether GR restarter is enabled. • Whether GR helper is enabled. • Number of GR restarters being restarted. • Number of GR helpers assisting in restarting the local device. Examples # Display FSPF GR status information. display fspf graceful-restart Graceful-restart capability : Disable Helper capability : Enable Graceful-restart period : 120 seconds FSPF graceful restart information of VSAN 1: Number of neighbors under helper : 0 Number of restarting neighbors : 0 FSPF graceful restart information of VSAN 2: Number of neighbors under helper : 0 Number of restarting neighbors : 0

Table 25 Command output

Field Description Graceful-restart capability Indicates whether GR restarter capability is enabled: Enable or Disable. Helper capability Indicates whether GR helper capability is enabled: Enable or Disable. Number of neighbors under helper Number of neighbors acting as GR helpers. Number of restarting neighbors Number of neighbors acting as GR restarters. Related commands • fspf graceful-restart • fspf graceful-restart helper • fspf graceful-restart interval display fspf lsdb Use display fspf lsdb to display FSPF link state database (LSDB) information. Syntax display fspf lsdb [ vsan vsan-id ] Views Any view Predefined user roles network-admin network-operator Parameters vsan vsan-id: Specifies a VSAN by its ID in the range of 1 to 3839. If you do not specify a VSAN, this command displays LSDB information for all VSANs. Usage guidelines The FSPF LSDB information includes the total number of link state records (LSRs) and information about each LSR. Examples # Display FSPF LSDB information. display fspf lsdb FSPF LSDB information of VSAN 1(01): Total LSR count: 2 FSPF Link State Database for Domain 01 LSR Type : 1 LSR Age : 0 LSR Incarnation number : 0x80000008 LSR Checksum : 0x7deb Number of links : 1

NbrDomainID IfIndex NbrIfIndex LinkType Cost

-------------------------------------------------------- 2 0x68 0x68 1 265 FSPF Link State Database for Domain 02 LSR Type : 1 LSR Age : 6 LSR Incarnation number : 0x80000008 LSR Checksum : 0x7dea Number of links : 1 NbrDomainID IfIndex NbrIfIndex LinkType Cost -------------------------------------------------------- 1 0x68 0x68 1 265 Table 26 Command output Field Description FSPF LSDB information of VSAN LSDB information for a VSAN. The value in parentheses is the domain ID in decimal of the local switch. FSPF Link State Database for Domain LSDB information for a domain ID (switch). LSR Type LSR type, which can only be Switch Link Record (0x01). LSR Incarnation number LSR instance number. NbrDomainID Neighbor domain ID. IfIndex Outgoing interface index of the local switch. NbrIfIndex Neighbor interface index. Link Type Link type: • 0x01—Point-to-point. • 0xF0-FF—Vendor-defined. Cost Link cost. display fspf neighbor Use display fspf neighbor to display FSPF neighbor information. Syntax display fspf neighbor [ vsan vsan-id ] Views Any view Predefined user roles network-admin network-operator Parameters vsan vsan-id: Specifies a VSAN by its ID in the range of 1 to 3839. If you do not specify a VSAN, this command displays information about all FSPF neighbors.

The FSPF neighbor information includes the following details:

• Neighbor domain ID. • Neighbor interface index. • Outgoing interface index of the local switch. • Remaining dead interval of the neighbor. • Neighbor state. Examples # Display FSPF neighbor information. display fspf neighbor FSPF neighbor information of VSAN 1(01): Interface NbrDomain IfIndex NbrIfIndex Dead Time State Fc1/0/1 2 0x68 0x68 00:01:06 Full Table 27 Command output Field Description FSPF neighbor information of VSAN FSPF neighbor information for a VSAN. The value in parentheses is the domain ID in decimal of the local switch. Interface Interface name of the local switch. NbrDomain Neighbor domain ID in decimal. IfIndex Outgoing interface index of the local switch. NbrIfIndex Neighbor interface index. Dead Time Remaining dead interval of the neighbor. If no hello packet is received from the neighbor after this interval, the neighbor state changes to Init. State Neighbor state: • Down—The neighbor does not start negotiation. • Init—The neighbor has started negotiation. • DB_Exchange—The neighbor has been discovered. • DB_Wait—The local switch has sent the LSR. • DB_Ack_Wait—The neighbor has sent the LSR. • Full—Synchronization is complete. display fspf statistics Use display fspf statistics to display FSPF statistics. Syntax display fspf statistics [ vsan vsan-id ] Views Any view Predefined user roles network-admin

vsan vsan-id: Specifies a VSAN by its ID in the range of 1 to 3839. If you do not specify a VSAN, this

command displays the FSPF statistics for all VSANs. Usage guidelines FSPF statistics contain global statistics and interface statistics. • Global statistics—Contain the current number of SPF calculations, number of error packets, total number of packets received and sent. • Interface statistics—Contain the total number of packets received and sent on each interface. Examples # Display FSPF statistics. display fspf statistics FSPF statistics of VSAN 1(01): SPF computing count: 6 Statistics counters: Bad packet : 0 Neighbor unknown : 0 Timer mismatch : 0 Neighbor state low : 0 Bad LSR : 0 Packet statistics: Type Input Output HELLO 50 50 LSU 5 5 LSA 4 4 Interface Fc1/0/1 statistics: Type Input Output HELLO 50 50 LSU 5 5 LSA 4 4 Table 28 Command output Field Description FSPF statistics of VSAN FSPF statistics for a VSAN. The value in parentheses is the domain ID in decimal of the local switch. SPF computing count Number of SPF calculations. Interface statistics Packet statistics on the interface. Bad packet Number of error packets. Timer mismatch Number of packets whose hello or dead interval does not match that of the neighbor. Bad LSR Number of error LSRs. Neighbor unknown Number of packets received from unknown neighbors. Neighbor state low Number of LSUs and LSAs received in Init state. Type Packet type: Hello, LSU, or LSA. Input Number of packets received.

Number of packets sent.

Related commands reset fspf counters fc route-static Use fc route-static to configure a static FC route. Use undo fc route-static to delete a static FC route. Syntax fc route-static fcid { mask | mask-length } interface-type interface-number [ cost cost-value ] undo fc route-static fcid { mask | mask-length } interface-type interface-number Default No static FC route exists. Views VSAN view Predefined user roles network-admin Parameters fcid: Specifies the destination FC address of the static FC route, in the range of 0x010000 to 0xFFFFFF (hexadecimal). mask: Specifies a hexadecimal mask of the FC address. This argument is used together with the fcid argument. The value of this argument can be 0xFF0000, 0xFFFF00, or 0xFFFFFF. mask-length: Specifies a decimal mask of the FC address. This argument is used together with the fcid argument. The value of this argument can be 8, 16, or 24. interface-type interface-number: Specifies the outgoing interface of the static FC route, which must be an existing FC interface or VFC interface on the FC switch. cost cost-value: Specifies the cost of the route, in the range of 0 to 65535 and defaulting to 0. Usage guidelines Static routes are routes that are manually configured by an administrator. After an administrator configures a static route, an FC frame to the specified destination is forwarded along the static route. In a simple network, static routes are enough for implementing network connectivity. When the network fails or the network topology changes, you must manually modify the static routes. Static routes support equal-cost routes. When you configure multiple equal-cost static routes to the same destination but with different outgoing interfaces, equal-cost routes are generated. Examples # Add a static FC route: • The destination FC address is 0x010000.

The mask length is 8.

• The outgoing interface is FC 1/0/1. • The cost is 20. system-view [Sysname] vsan 5 [Sysname-vsan5] fc route-static 010000 8 fc 1/0/1 cost 20 # Add a static FC route: • The destination FC address is 0x010000. • The mask length is 8. • The outgoing interface is VFC 4. • The cost is 20. system-view [Sysname] vsan 5 [Sysname-vsan5] fc route-static 010000 8 vfc 4 cost 20 Related commands display fc routing-table fspf cost Use fspf cost to configure the FSPF cost for the interface in a VSAN. Use undo fspf cost to restore the default. Syntax fspf cost value vsan vsan-id undo fspf cost vsan vsan-id Default The FSPF cost of FC interfaces is calculated by using this formula: 1.0*1.062e12/baud rate. The default FSPF costs for VFC interfaces and FC aggregate interfaces are both 100. Views FC interface view, VFC interface view, FC aggregate interface view Predefined user roles network-admin Parameters value: Specifies the FSPF cost of the interface, in the range of 1 to 65535. vsan vsan-id: Specifies the VSAN to which the interface belongs, in the range of 1 to 3839. Usage guidelines Each link has a cost. The route selection algorithm uses this value to determine the best route. The smaller the interface FSPF cost, the smaller the link cost. Examples # Configure the FSPF cost of interface FC 1/0/1 in VSAN 4 as 1000. system-view

[Sysname] interface fc 1/0/1

[Sysname-Fc1/0/1] fspf cost 1000 vsan 4 # Configure the FSPF cost of interface VFC 1 in VSAN 4 as 1000. system-view [Sysname] interface vfc 1 [Sysname-Vfc1] fspf cost 1000 vsan 4 fspf dead-interval Use fspf dead-interval to configure the dead interval for the interface in a VSAN. Use undo fspf dead-interval to restore the default. Syntax fspf dead-interval value vsan vsan-id undo fspf dead-interval vsan vsan-id Default The dead interval is 80 seconds. Views FC interface view, VFC interface view, FC aggregate interface view Predefined user roles network-admin Parameters value: Specifies the dead interval of the interface in seconds, in the range of 2 to 65535. vsan vsan-id: Specifies the VSAN to which the interface belongs, in the range of 1 to 3839. Usage guidelines After two switches establish a neighbor relationship, they send hello packets at the hello interval to each other to maintain the neighbor relationship. The dead interval specifies the interval during which at least one hello packet must be received from a neighbor before the neighbor is considered nonexistent and is removed. The configured dead interval must be greater than the hello interval and must be the same at the two ends of the link. Examples # Configure the dead interval for interface FC 1/0/1 in VSAN 4 as 100 seconds. system-view [Sysname] interface fc 1/0/1 [Sysname-Fc1/0/1] fspf dead-interval 100 vsan 4 # Configure the dead interval for interface VFC 1 in VSAN 4 as 100 seconds. system-view [Sysname] interface vfc 1 [Sysname-Vfc1] fspf dead-interval 100 vsan 4 Related commands fspf hello-interval

Use fspf enable to enable FSPF for a VSAN.

Use undo fspf enable to disable FSPF for a VSAN. Syntax fspf enable undo fspf enable Default FSPF is enabled after a VSAN is created. Views VSAN view Predefined user roles network-admin Usage guidelines FSPF-related functions work in a VSAN only after you enable FSPF for the VSAN. Examples # Enable FSPF for VSAN 4. system-view [Sysname] vsan 4 [Sysname-vsan4] fspf enable fspf graceful-restart Use fspf graceful-restart to enable FSPF GR. Use undo fspf graceful-restart to disable FSPF GR. Syntax fspf graceful-restart undo fspf graceful-restart Default FSPF GR is disabled. Views System view Predefined user roles network-admin Usage guidelines FSPF graceful restart (GR) ensures nonstop forwarding of traffic by backing up FSPF configuration information in one of the following situations: • A protocol restart (for example, the FSPF process restart triggered by the process command).

An active/standby switchover.

GR involves the following roles: • GR restarter—GR-capable device where a protocol restart or active/standby switchover occurs • GR helper—The GR restarter's neighboring device that assists in the GR process Examples # Enable FSPF GR. system-view [Sysname] fspf graceful-restart Related commands • display fspf graceful-restart • fspf graceful-restart helper fspf graceful-restart helper Use fspf graceful-restart helper to configure a device to act as an FSPF GR helper. Use undo fspf graceful-restart helper to cancel the configuration. Syntax fspf graceful-restart helper undo fspf graceful-restart helper Default A device acts as an FSPF GR helper. Views System view Predefined user roles network-admin Usage guidelines The switch can assist the GR restarter in completing the GR process only after it is configured as an FSPF GR helper. Examples # Configure the device to act as an FSPF GR helper. system-view [Sysname] fspf graceful-restart helper Related commands • display fspf graceful-restart • fspf graceful-restart fspf graceful-restart interval Use fspf graceful-restart interval to configure the maximum FSPF GR interval.

Use undo fspf graceful-restart interval to restore the default.

Syntax fspf graceful-restart interval interval-value undo fspf graceful-restart interval Default The maximum FSPF GR interval is 120 seconds. Views System view Predefined user roles network-admin Parameters interval-value: Specifies the maximum FSPF GR interval in seconds, in the range of 40 to 1800. Usage guidelines If the GR restarter fails to complete the GR process within the maximum FSPF GR interval, it immediately exits the GR process. Examples # Configure the maximum FSPF GR interval as 100 seconds. system-view [Sysname] fspf graceful-restart interval 100 Related commands display fspf graceful-restart fspf hello-interval Use fspf hello-interval to configure the hello interval for the interface in a VSAN. Use undo fspf hello-interval to restore the default. Syntax fspf hello-interval value vsan vsan-id undo fspf hello-interval vsan vsan-id Default The hello interval is 20 seconds. Views FC interface view, VFC interface view, FC aggregate interface view Predefined user roles network-admin Parameters value: Specifies the hello interval in the range of 1 to 65534 seconds. vsan vsan-id: Specifies the VSAN to which the interface belongs, in the range of 1 to 3839.

The hello interval specifies the time between the hello packets sent periodically by the switch to discover

and maintain neighbor relationships. The configured hello interval must be smaller than the dead interval and must be the same at the two ends of the link. Examples # Configure the hello interval for interface FC 1/0/1 in VSAN 4 as 10 seconds. system-view [Sysname] interface fc 1/0/1 [Sysname-Fc1/0/1] fspf hello-interval 10 vsan 4 # Configure the hello interval for interface VFC 1 in VSAN 4 as 10 seconds. system-view [Sysname] interface vfc 1 [Sysname-Vfc1] fspf hello-interval 10 vsan 4 Related commands fspf dead-interval fspf min-ls-arrival Use fspf min-ls-arrival to configure the minimum LSR arrival interval for a VSAN. Use undo fspf min-ls-arrival to restore the default. Syntax fspf min-ls-arrival value undo fspf min-ls-arrival Default The minimum LSR arrival interval is 1 second. Views VSAN view Predefined user roles network-admin Parameters value: Specifies the minimum LSR arrival interval in the range of 0 to 60 seconds. Usage guidelines The minimum LSR arrival interval specifies the time between receiving LSRs in a VSAN. Any LSR instances of the same LSR received within this time are dropped. This helps avoid frequent SPF calculations caused by LSDB updating. Examples # Configure the minimum LSR arrival interval as 10 seconds for VSAN 2. system-view [Sysname] vsan 2 [Sysname-vsan2] fspf min-ls-arrival 10

Use fspf min-ls-interval to configure the minimum LSR refresh interval for a VSAN.

Use undo fspf min-ls-interval to restore the default. Syntax fspf min-ls-interval value undo fspf min-ls-interval Default The minimum LSR refresh interval is 5 seconds. Views VSAN view Predefined user roles network-admin Parameters value: Specifies the minimum LSR refresh interval in the range of 1 to 60 seconds. Usage guidelines The minimum LSR refresh interval specifies the interval at which LSRs are refreshed. To reduce SPF calculations and LSR flooding in a fabric caused by frequent LSR refreshing, the switch cannot refresh local LSRs within this interval. Examples # Configure the minimum LSR refresh interval as 10 seconds for VSAN 2. system-view [Sysname] vsan 2 [Sysname-vsan2] fspf min-ls-interval 10 fspf retransmit-interval Use fspf retransmit-interval to configure the LSR retransmission interval for the interface in a VSAN. Use undo fspf retransmit-interval to restore the default. Syntax fspf retransmit-interval value vsan vsan-id undo fspf retransmit-interval vsan vsan-id Default The LSR retransmission interval is 5 seconds. Views FC interface view, VFC interface view, FC aggregate interface view Predefined user roles network-admin