Intek Elite 16D Installation & Programming Manual
Read Online
Read the Intek Elite 16D Installation & Programming Manual online using the built-in PDF viewer.
Text of the manual
Proudly Designed and Manufactured in New Zealand
Designed & Manufactured in New Zealand to Meet NZS:4301/93
INSTALLATION NOTES ....................................................................................4
This Elite 16D alarm control panel has been designed to provide the most requested features for both the installer &
MAIN CONTROL CABINET
n/c or n/o
Please note the following important points in the end-of-line examples shown on pages 7 & 8;
EARTH - Always connect the mains earth to the appropriate terminals on the mains terminal block. If required a
F1 F2 Batt
When the Elite is displaying codes and address values in program mode it may be necessary to display the 9
The Elite LED Keypad consists of; an 18 button, backlit silicone rubber keypad, 20 LED indicators and an internal
This Elite 16D alarm panel has an event memory which stores the 40 most recent events including all alarm events,
Area "A" Partition
Separate the two keypad halves by carefully inserting a small screwdriver into the release slots on the bottom edge
The Elite 16D is fully high level compatible with the new Auto-tune RX-16 radio receiver. The addition of this receiver
HOW TO PROGRAM
represents the PROGRAM key and -
TO EXIT PROGRAM MODES
USER CODE PERMISSIONS (Code Options) 1st Set - P25E-P48E
OUTPUT OPTIONS FIRST SET- P101E-P108E
P111E 1E Keypad panic to Output #1
OUTPUT AUTO ON/OFF TIME ZONES - P121E - 128E
The block of addresses from P140E to P158E are used to assign the basic function options of each keypad in the
P170E 1-8 Time Zone to use for Auto Arm or Disarm (Default 0) - This option will determine which Time
PARTITION "A" SPECIFIC OUTPUT OPTIONS second set - P181E - P188E
PARTITION "A" KEYPAD OPTIONS - P191E - P196E
PARTITION "A" MISCELLANEOUS KEYPAD OPTIONS - P198E
PARTITION "A" MISCELLANEOUS OPTIONS 2nd set - P199E
MISCELLANEOUS OPTIONS - P201E to P206E
SINGLE OR DUAL ZONE INPUT (8 or 16 zones) - P300E
P336E 1-8E Zone is a handover - Where options 1-8 represent zones 1-8. Zones defined at this address as
SYSTEM DELAYS AND TIMERS - P401E to P459E
P343E is used to assign a zone to be the door position monitor input and address P344E is used to assign a zone
ENROLLING RADIO DETECTORS - P501E to P516E
ENROLLING RADIO KEYS - P541E - P556E
Option 5 Radio user #1 will disarm - When this option is enabled, radio user #1 will disarm which ever
MAPPING RADIO USERS TO OUTPUTS - P601E to P616E
PROGRAMMING DAYLIGHT SAVING ADJUSTMENTS - P712E - P717E
P722E Active Outputs - This option will cause the keypad to display the outputs which are currently
SETTING THE REAL TIME CLOCK - P730E - P734E
Another powerful feature available from your Elite 16D control communicator is Command Control. This feature is
alarm event messages except
Elite Command Control provides a powerful, easy to use remote telephone control of your control communicator.
The communicator facility of this Elite controller has been designed to provide optimum flexibility in the way in which
The flexibility of the system is further extended by the way in which you can assign different reporting formats to
COMMUNICATOR REPORTING SCENARIOS
To assist you in programming your Elite communicator we have set out a number of the most common reporting
DEFINE REPORTING FORMATS - P231E - P236E
ZONE ACTIVATION SCENARIO MAPPING - P241E - P256E
This group of addresses is used to map the eight possible low zone tampers to one of the four possible reporting
This group of addresses is used to define which events will be reported and also to assign these Area based
P322E 1-8E Area A Reporting Options - Default 1,2&4 1 = Sent Set / Unset
Option 1 Enable Communicator - This option is used to activate the communicator hardware. If this
This block of addresses from P620E to P658E is used to assign the Ademco Contact ID codes to all of the
P662E 1-8E Voice Messages Mapped to Zone 2 Activation's - Default 1
P728E Answer incoming call - provided a user with option 5 set (P49-P72) enters in P728E while in
In addition to the programmable Contact ID code assignments defined at P 620E - P658E there are a number of
CLIENT MODE PROGRAMMING
P50E Extended Access Permissions for user #2 - Default 3 1 = Code can override DOTL Page 19
P104E Output #4 Primary options - Default none 4 = One Shot (lock-out) Page 20
P172E Area "A" primary options for output #2 - Default 1 & 3 2 = 24 hour activation's Page 24
PROGRAMMING PARTITION 'B' PARAMETERS
2 = Unset Partition When Time Zone Starts
P394E 24Hr alarms to keypads - Default 1-8 Page 24-28
P301E Zone 1 vibration sensitivity - Default 0 0 = No vibration sensor Page 30
P413E Zone 13 entry delay - Default 0 Page 32
SET RADIO DETECTOR OPTIONS
RADIO KEY OPTIONS 2ND SET
P703E Time Zone 8 start time - Default 0 Page 37
COMMUNICATOR REPORTING SCENARIOS Page 46
P466E Zone 6 exclude mapped to scenario 1-4 default 1 Page 49
P323E Area A reports mapped to scenario 1-4 default 1 Page 52
P660E Voice message number 1-8 mapped to panic alarm - default 1 Page 54
ARMING THE PANEL (CODE = A VALID 1-6 DIGIT USER CODE)
OR
The mode for arming above depends upon the programmed panel operation. Also, the arming mode can vary from
one keypad to another, depending upon how the system is programmed.
If the arm sequence was successful, the relevant armed LED will turn on (ARMED, A or B) or a combination of
these, depending upon the areas assigned to a particular user code.
DISARMING THE PANEL
PRESS
If the disarm sequence was successful, the relevant armed LED (ARMED, A or B) will turn off depending upon the
area/s assigned to a particular user code.
EXCLUDING ZONES
FIRST ARM THE ALARM AS ABOVE
DURING THE EXIT DELAY PRESS
(The exclude LED will turn ON).
Next; Select any zone/s from 1-8 that you wish to exclude by pressing numbers 1-8 on the keypad. The appropriate
green zone led will turn on to show that the zone/s will be excluded.
To exclude zones 9-16 (if the panel is set up as a 16 zone panel);
PRESS again.
The "Aux." led should be ON. Now numbers 1-8 (and zone leds 1-8) will select 9-16 (eg 1=9 - 8=16)
Once all the zones you wish to exclude have been selected;
PRESS .
This will then start the full exit delay timer and you should exit the building.
MONITOR MODE ARMING
PRESS
OR
Above choice depends upon programmed options.
The relevant monitor led (either ARMED, A or B) will flash to indicate that monitor mode is on.
MONITOR MODE DISARMING
PRESS
Monitor mode led (ARMED, A or B) will turn OFF.
If the keypad is programmed for one button monitor mode disarming then simply pressing the button
will disarm monitor mode.
CONTROL OPERATION
If the system has been programmed with a control function, then the control mode is operated as follows;
The control led on the keypad will turn ON.
If control mode was set as a timed function, the control led will turn off automatically after a pre-defined period.
If the control mode was set as a toggle function entering in the above sequence will turn off the control function and
the control led will turn off.
Also, if the control function is used to control a security door which has door open too long monitoring this function
can be inhibited temporarily by any user with DOTL override assigned to their code.
CONTROL DOTL OVERRIDE
PRESS
Program LED will turn ON.
PRESS .
Control LED will flash.
PRESS
The control led will continue to flash. The controlled door can now be opened for an indefinite period of time. Once
the door closes again, the control led will turn OFF and the door will alarm if the door is forced open or left open too
long.
VIEWING MEMORY DISPLAY
If an alarm occurs the event will be stored in the Elite's 40 event memory which will cause the "MEMORY" indicator
to flash on and off.
To display the memory events;
PRESS
The memory led will turn on and events will be displayed sequentially starting with the newest event. The display
changes to a new event every 2 seconds.
When all of the events have been displayed,. the memory led turns off and the keypad is back in normal mode.
To stop the memory display at any time and return to normal mode press .
COMMAND CONTROL OPERATING INSTRUCTIONS
INITIATING A PRINT COMMAND
(program LED on steady)
THEN ENTER <726>
Up to 63 events will then be transferred to the printer.
Note; The printer must be connected and on-line to receive the event log information
INITIATING AN UPLOAD DOWNLOAD CONNECTION FROM THE PANEL
There are two ways of initiating a pc upload/download connection with a dial-up link;
1) Direct dial-in. By default (provided the auto-answer rings are turned on by entering a value other than "0" at
P329E) the panel will answer an incoming call from a pc and initiate modem handshaking to start the connection.
2) User initiated auto-answer If a user who has permission to locally initiate an upload/download link (option 5,
P49 - P72) enters client program mode and enters P728E, the panel will answer an incoming call from the pc after
2 rings and then start the modem handshaking.