NXC-IRS4 4-Port IR/S Card, 4 IR/S and 4 Inputs

NetLinx Control Cards and NetModules NetLinx Control Cards can be installed in either the NXF CardFrame, NI-4000, or NetModules. This document provides basic specifications and wiring information for the NetLinx Control cards. For detailed information on the cards, refer to the NetLinx CardFrame, Control Cards, and NetModules Instruction Manual. NXC-IRS4 4-Port IR/S Control Card The NXC-IRS4 4-Port IR/S Control Card provides four IR/Serial output control ports with LED status feedback. Each port in the NXC-IRS4 stores programmed commands for IR- or serial-controlled devices. Specifications Pinouts, Signals, and Functions NXC-IRS4 Channel Assignments The IRS4 channel settings listed in the following table set the IR output channels. The NXC-IRS4 can process up to two IR or serial device channel setting commands simultaneously. If more than two device commands are sent simultaneously, only the first two devices receive the commands. Programming Information NXC-IRS4 (FG2023) Specifications Power 110 mA @ +12 VDC power for sensors Operation: • IR 1-4: 4 IR/Serial control ports • Input 1-4: 4 input ports for closure or 0-5 VDC sensing, 200 mA Memory 32K of IR memory shared between four ports. IR Frequency range Support of high-frequency carriers up to 1.14 MHz. Status LEDs: Red LED shows IR transmission activity / yellow LED shows input status activity (2 LEDs per channel). LEDs light to indicate ON status: • LED 1: Channel 1 Input (yellow) • LED 2: Channel 1 IR Out (red) • LED 3: Channel 2 Input (yellow) • LED 4: Channel 2 IR Out (red) • LED 5: Channel 3 Input (yellow) • LED 6: Channel 3 IR Out (red) • LED 7: Channel 4 Input (yellow) • LED 8: Channel 4 IR Out (red) Connections/wiring: • Two 2-pin 3.5 mm captive-screw terminals • Two CC-NIRC IR Emitters Models: • NXC-IRS4 4-Port IR/S Card • NXM-IRS4 4-Port IR/S NetModule DEVICE_ID: $0108 NXC-IRS4 Pinouts, Signals, and Functions Pin Signal Function Pin Signal Function 1 GND Signal ground 10 Input #1 Logic input 2 Output #1 IR data 11 Input #2 Logic input 3 GND Signal ground 12 Input #3 Logic input 4 Output #2 IR data 13 Input #4 Logic input 5 GND Signal ground 14 Power +12 VDC 6 Output #3 IR data 15 --------------- no connection 7 GND Signal ground 16 --------------- no connection 8 Output #4 IR data 17 --------------- no connection 9 GND Signal ground 18 --------------- no connection 19 --------------- no connection 20 --------------- no connection NXC-IRS4 Channel Assignments Channel Description 1-255 Generates the IR or serial command assigned to that channel. 1-199 Provides intelligent feedback; if a channel with no IR command is turned on, the card will turn that channel off. Ports 1-4 Generates PUSH and RELEASE statements corresponding to the state of inputs 1 - 4. A contact closure to GND is reported as a PUSH. • The PUSH and RELEASE channel is 255. • Channel reporting status is 255. • Channel 255 changes are disabled after receipt of the ’PON’ command. NXC-IRS4 SEND_COMMANDS CAROFF Disable the IR carrier signal until a 'CARON' command is received. Syntax: SEND_COMMAND ,"'CAROFF'" Example: SEND_COMMAND IR_1,"'CAROFF'" Stops transmitting IR carrier signals to the IR_1 port. CARON Enable the IR carrier signals (default). Syntax: SEND_COMMAND ,"'CARON'" Example: SEND_COMMAND IR_1,"'CARON'" Starts transmitting IR carrier signals to the IR_1 port. CH Send IR pulses for the selected a channel. All channels below 100 are transmitted as two digits. If the IR code for ENTER (function #21) is loaded, an Enter will follow the number. If the channel is greater than or equal to (>=) 100, then IR function 127 or 20 (whichever exists) is generated for the one hundred digit. Uses 'CTON' and 'CTOF' times for pulse times. Syntax: SEND_COMMAND ,"'CH'," Channel number = 0 - 199. Example: SEND_COMMAND IR_1,"'CH',18" The NXC-IRS4 performs the following: • Transmits IR signals for 1 (IR code 11). The transmit time is set with the CTON command. • Waits until the time set with the CTOF command elapses. • Transmits IR signals for 8 (IR code 18). • Waits for the time set with the CTOF command elapses. If the IR code for Enter (IR code 21) is programmed, the IRS4 performs the following steps. • Transmits IR signals for Enter (IR code 21). • Waits for the time set with the CTOF command elapses. CP Halt and Clear all active or buffered IR com- mands, and then send a single IR pulse. Set the Pulse and Wait times with the 'CTON' and 'CTOF' commands. Syntax: SEND_COMMAND ,"'CP'," Code = IR port's channel value 0 - 252 (253 - 255 reserved). Example: SEND_COMMAND IR_1,"'CP',2" Clears the active/buffered commands and pulses IR_1 port's channel 2. CTOF Set the duration of the Off time (no signal) between IR pulses for channel and IR function transmissions. Off time settings are stored in non-volatile memory. This command sets the delay time between pulses generated by the 'CH' or 'XCH' send commands in tenths of seconds. Syntax: SEND_COMMAND ,"'CTOF',

For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).

1207 ©2007 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX. AMX reserves the right to alter specifications without notice at any time. 3000 RESEARCH DRIVE, RICHARDSON, TX 75082 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993 • www.amx.com 93-2023 REV: E NXC-IRS4 SEND_COMMANDS (Cont.) POD Disable previously active 'PON' (power on) or 'POF' (power off) com- mand settings. This command is used in conjunction with the I/O Link command. Channel 255 changes are enabled. Syntax: SEND_COMMAND ,"'POD'" Example: SEND_COMMAND IR_1,"'POD" Disables the 'PON' and 'POF' command settings on the IR_1 device. POF Turn OFF a device connected to an IR port based on the status of the corresponding I/O Link input. If at any time the IR sensor input reads that the device is ON (such as if someone turned it on manually at the front panel), IR function 28 (if available) or IR function 9 is automatically generated in an attempt to turn the device back OFF. If three attempts fail, the IR port will continue executing commands in the buffer. If there are no commands in the buffer, the IR port will continue executing commands in the buffer and trying to turn the device OFF until a 'PON' or 'POD' command is received. If the IR port fails to turn the device OFF, a PUSH and RELEASE is made on channel 254 to indicate a power failure error. You can only use the 'PON' and 'POF' commands when an IR device has a linked I/O channel. Channel 255 changes are disabled after receipt of this command. You can only use the PON and POF commands when an IR device has a linked I/O channel. Syntax: SEND_COMMAND ,"'POF'" Example: SEND_COMMAND IR_1,"'POF'" Sends power down IR commands 28 (if present) or 9 to the IR_1 device. PON Turn ON a device connected to an IR port based on the status of the corresponding I/O Link input. If at any time the IR sensor input reads that the device is OFF (such as if one turned it off manually at the front panel), IR function 27 (if available) or IR function 9 is automatically gener- ated in an attempt to turn the device back ON. If three attempts fail, the IR port will continue executing commands in the buffer and trying to turn the device On. If there are no commands in the buffer, the IR port will continue trying to turn the device ON until a 'POF' or 'POD' command is received. If the IR port fails to turn the device ON, a PUSH and RELEASE is made on channel 254 to indicate a power failure error. You can only use the 'PON' and 'POF' commands when an IR device has a linked I/O channel. Channel 255 changes are disabled after receipt of this command. Syntax: SEND_COMMAND ,"'PON'" Example: SEND_COMMAND IR_1,"'PON'" Sends power up IR commands 27 or 9 to the IR_1 port. PTOF Set the time duration between power pulses in .10-second increments. Time is given in 1/10ths of a second. This time increment is stored in permanent memory. This command also sets the delay between pulses generated by the 'PON' or 'POF' send commands in tenths of seconds. It also sets the delay required after a power ON command before a new IR function can be generated. This gives the device time to power up and get ready for future IR commands. It also sets the delay required after a power ON command before a new IR function can be generated. This gives the device time to power up and get ready for future IR commands. Syntax: SEND_COMMAND ,"'PTOF',

Other Network Card Manuals