Ledj LEDJ232 Operation & User’s Manual
Read Online
Read the Ledj LEDJ232 Operation & User’s Manual online using the built-in PDF viewer.
Text of the manual
Event Spot DL/WW User Manual
2
Safety advice
WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL
CAREFULLY BEFORE YOUR INITIAL START-UP!
•� Before�your�initial�start-up,�please�make�sure�that�there�is�no�damage�caused�during�transportation.
•� Should�there�be�any�damage,�consult�your�dealer�and�do�not�use�the�equipment.
•� To�maintain�the�equipment�in�good�working�condition�and�to�ensure�safe�operation,�it�is�necessary��
for�the�user�to�follow�the�safety�instructions�and�warning�notes�written�in�this�manual.
•� Please�note�that�damages�caused�by�user�modifications�to�this�equipment�are�not�subject�to�warranty.
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance
of this manual or any unauthorised modification to the equipment.
OPERATING DETERMINATIONS
If�this�equipment�is�operated�in�any�other�way,�than�those�described�in�this�manual,�the�product�may�suffer�damage�and��
the�warranty�becomes�void.�Incorrect�operation�may�lead�to�danger�e.g:�short-circuit,�burns�and�electric�shocks�etc.�
Do�not�endanger�your�own�safety�and�the�safety�of�others!�
Incorrect�installation�or�use�can�cause�serious�damage�to�people�and/or�property.
CAUTION!
KEEP THIS EQUIPMENT
AWAY FROM RAIN,
MOISTURE AND LIQUIDS
CAUTION!
TAKE CARE USING
THIS EQUIPMENT!
HIGH VOLTAGE-RISK
OF ELECTRIC SHOCK!!
•� Never�let�the�power�cable�come�into�contact�with�other�
cables.�Handle�the�power�cable�and�all�mains�voltage��
connections�with�particular�caution!
•� Never�remove�warning�or�informative�labels�from�the�unit.
•� Do�not�open�the�equipment�and�do�not�modify�the�unit.
•� Do�not�connect�this�equipment�to�a�dimmer�pack.
•� Do�not�switch�the�equipment�on�and�off�in�short�intervals,�
as�this�will�reduce�the�system’s�life.
•� Only�use�the�equipment�indoors.
•� Do�not�expose�to�flammable�sources,�liquids�or�gases.
•� Always�disconnect�the�power�from�the�mains�when��
equipment�is�not�in�use�or�before�cleaning!�Only�handle�
the�power-cable�by�the�plug.�Never�pull�out�the�plug�by�
pulling�the�power-cable.
•� Make�sure�that�the�available�mains�supply�voltage�is�
between�100~240V�AC,�50/60Hz.
•� Make�sure�that�the�power�cable�is�never�crimped�or��
damaged.�Check�the�equipment�and�the�power�cable�
periodically.
•� If�the�equipment�is�dropped�or�damaged,�disconnect�the�
mains�power�supply�immediately�and�have�a�qualified�
engineer�inspect�the�equipment�before�operating�again.�
�
•� If�the�equipment�has�been�exposed�to�drastic��
temperature�fluctuation�(e.g.�after�transportation),��
do�not�connect�power�or�switch�it�on�immediately.��
The�arising�condensation�might�damage�the�equipment.�
Leave�the�equipment�switched�off�until�it�has�reached�
room�temperature.
•� If�your�product�fails�to�function�correctly,�stop�use�
immediately.�Pack�the�unit�securely�(preferably�in�the��
original�packing�material),�and�return�it�to�your�Pro�Light�
dealer�for�service.
•� Only�use�fuses�of�same�type�and�rating.
•� Repairs,�servicing�and�power�connection�must�only�be��
carried�out�by�a�qualified�technician.�THIS�UNIT�CONTAINS�
NO�USER�SERVICEABLE�PARTS.
•� This�lighting�fixture�is�for�professional�use�only�-�it�is�
not�designed�for�or�suitable�for�household�use.�The�
product�must�be�installed�by�a�qualified�technician�in�
accordance�with�local�territory�regulations.�The�safety�of�
the�installation�is�the�responsibility�of�the�installer.�The�
fixture�presents�risks�of�severe�injury�or�death�due�to�fire�
hazards,�electric�shock�and�falls.
•� Warning!�Risk�Group�2�LED�product�according�to�
EN�62471.�Do�not�view�the�light�output�with�optical�
instruments�or�any�device�that�may�concentrate�the�beam.
•� WARRANTY:�One�year�from�date�of�purchase.
Event Spot DL/WW User Manual
3
0m
2m
3m
4m
5m
1m
10°
45°
4°
54400
28400
13640
7109
6040
3160
3400
1780
2180
1140
4° - Lux
10° - Lux
3140
786
349
197
126
45° - Lux
Event Spot DL
47600
24000
11890
5989
5290
2660
2980
1500
1900
958
4° - Lux
10° - Lux
2620
654
291
164
105
45° - Lux
Event Spot WW
Product overview & technical specifications
The�Event�Spot�compact LED�Pinspots�are�powered�by�a�15W�LED�that�has�the�brightness�and�output�of�a�100W�
halogen�lamp.�Featuring�a�4°�beam�angle�and�supplied�with�two�optional�lenses�(10°�and�45°)�the�fixture�is�easily�
directed�at�displays�for�highlighting�and�pinspotting,�it�can�also�be�used�to�create�mood�lighting�on�a�restaurant�
table,�or�to�spotlight�displays�in�store.�
Event Spot DL/WW
135mm
173mm
203mm
•�1�x�15W�warm�white�LED�(3000K)�-�LEDJ232
•�1�x�15W�day�light�LED�(5000K)�-�LEDJ233
•�Beam�angle:�4°�native,�10°�&�45°�frost�lenses�supplied
•�1.1kHz�refresh�rate
•�DMX�channels:�2
•�Manual�and�master/slave�modes
•�0-100%�dimming�and�variable�strobe
•�Bracket�allows�for�multiple�rigging�or�floor�standing�applications
•�4�push�button�menu�with�LCD�display
•�IEC�power�input/output�trailing�sockets
•�3-Pin�XLR�input/output�trailing�sockets
•�Convection�cooled
•�Optional�IR�remote�(LEDJ90E)
Specifications
Event Spot DL/WW
Power�consumption
17W
Power�supply
100~240V,�50/60Hz
Fuse
T0.5A�250V
Dimensions
203�x�135�x�173mm
Weight
1.2kg
Order�code
LEDJ232�-�WW�Version
Order�code
LEDJ233�-�DL�Version
Event Spot DL/WW User Manual
4
Technical specifications
01�-�Earth�point
02�-�LCD�display
03�-�Function�buttons
04�-�3-Pin�DMX�input�trailing�socket
05�-�3-Pin�DMX�output�trailing�socket
06�-�IEC�power�input�trailing�socket
07�-�IEC�power�output�trailing�socket
08�-�Fuse�T0.5A�250V
09�-�Hanging�bracket
10�-�Hanging�bracket�adjustable�knob
In�the�box:�1 x fixture,
1 x 10° frost lens,
1 x 45° frost lens,
1 x power cable
& 1 x user manual
MENU
UP
ENTER
100-240V
~50/60Hz
FUSE:
T0.5A
250V
DOWN
POWER
OUTPUT
POWER
INPUT
DMX
INPUT
DMX
OUTPUT
10
09
01
06
03
04
10
05
08
07
02
Event Spot DL/WW User Manual
5
Operating instructions
MENU
DMX MODE
ADDR
DMX address setting
DMX ADDR
001
DMX ADDR
512
IR. REMOTE
IR remote on/off
IR. REMOTE
OFF
IR. REMOTE
ON
DIMMER
Dimmer response
DIMMER
RESP_01
DIMMER
RESP_02
Manual
Dim: F:
Manual mode
Manual
Dim:00 F:00
Manual
Dim:99 F:99
CHANNEL
CH 02
DMX channel mode
SLAVE MODE
Slave mode
Event Spot DL/WW User Manual
6
DMX mode:
Operating�in�a�DMX�control�mode�environment�gives�the�user�the�greatest�flexibility�when�it�comes��
to�customising�or�creating�a�show.�In�this�mode�you�will�be�able�to�control�each�individual�trait�of�the�
fixture�and�each�fixture�independently.�
To�access�the�DMX�address�mode,�press�the�“MENU”�button�on�the�rear�of�the�unit�to�show��
“DMX MODE ADDR” on�the�LCD�display.�Now�press�the�“ENTER”�button�and�use�the�“UP”�and�“DOWN”�
buttons�to�set�the�required�DMX�address.�Press�the�“ENTER”�button�to�confirm�the�setting.
To�exit�out�of�any�of�the�above�options,�press�the�“MENU”�button.�
To�access�the�DMX�channel�mode,�press�the�“MENU”�button�on�the�rear�of�the�unit�to�show��
“CHANNEL CH 02” on�the�LCD�display.�Press�the�“ENTER”�button�to�confirm�the�setting.
To�exit�out�of�any�of�the�above�options,�press�the�“MENU”�button.
Master/slave mode:
To�set�the�master�unit,�press�the�“MENU”�button�on�the�rear�of�the�master�unit�to�select�manual�mode.�
To�set�the�other�units�in�slave�mode,�press�the�“MENU”�button�on�the�rear�of�the�unit�to�show�“SLAVE
MODE”�on�the�LCD�display.�Press�the�“ENTER”�button�to�confirm�the�setting.
To�exit�out�of�any�of�the�above�options,�press�the�“MENU”�button.
IR remote on/off:
To�set�the�IR�remote�on/off,�press�the�“MENU”�button�on�the�rear�of�the�unit�to�show�“IR. REMOTE”�on�
the�LCD�display.�Press�the�“ENTER”�button�and�use�the�“UP”�and�“DOWN”�buttons�to�select�“ON” or
“OFF”.�Press�the�“ENTER”�button�to�confirm�the�setting.
To�exit�out�of�any�of�the�above�options,�press�the�“MENU”�button.
Dimmer response:
To�set�the�dimmer�response,�press�the�“MENU”�button�on�the�rear�of�the�unit�to�show�“DIMMER”�on�the�
LCD�display.�Press�the�“ENTER”�button�and�use�the�“UP”�and�“DOWN”�buttons�to�select�“RESP_01” or
“RESP_02”.�Press�the�“ENTER”�button�to�confirm�the�setting.
To�exit�out�of�any�of�the�above�options,�press�the�“MENU”�button.
Operating instructions
Channel
Value
Function
1
000-255
Master�dimmer�(0-100%)
2
000-002
No�function
003-255
Strobe�(slow-fast)
2 channel mode:
Event Spot DL/WW User Manual
7
Manual dimming mode:
To�access�the�manual�dimming�mode,�press�the�“MENU”�button�on�the�rear�of�the�unit�to�show��
“Manual”�on�the�LCD�display.�The�unit�is�now�in�manual�dimming�mode.�Press�the�“ENTER”�button��
and�use�the�“UP”�and�“DOWN”�buttons�to�set�the�brightness�from�“00” - “99”.�Press�the�“ENTER”�button��
again�and�use�the�“UP”�and�“DOWN”�buttons�to�set�the�strobe�speed�from�“00” - “99”.�
Press�the�“ENTER”�button�to�confirm�the�setting.
(00 = LED off/strobe off, 99 = LED at full brightness/strobe fast)
To�exit�out�of�any�of�the�above�options,�press�the�“MENU”�button.�
Operating instructions
Event Spot DL/WW User Manual
8
Optional IR remote functions:�
Button functions:
DMX address examples:
To�set�the�DMX�address;
•�Press�the�“S”�button,�the�LED�illuminates�in�full,�you�can�now�start�to�set�the�DMX�address
•�Select�the�required�3�digit�DMX�address�(eg�001�or�136�or�275)�the�unit�will�then�flash��
to�confirm�the�address�has�been�set
•�Now�press�the�“DMX�MODE”�button�to�save�the�new�address�into�the�memory
Important notes:
•�Set�the�DMX�address�on�each�fixture�before�plugging�into�the�DMX�controller
•�The�IR�remote�is�cannot�be�used�when�the�fixture(s)�are�being�controlled�by�a�DMX�controller
•�The�maximum�transmitter�distance�is�10m�-�Please�make�sure�that�you�have�the�IR�remote�aimed�
directly�at�the�front�panel�of�each�fixture�to�be�programmed
•�If�you�do�not�press�the�“DMX�MODE”�button�after�you�have�changed�the�DMX�address,��
when�you�power�down�the�fixture�it�will�lose�the�address�you�have�set
01�-�Blackout
02�-�To�set�the�brightness�of�the�LED�either��
����select�20%,�50%�or�100%�or�alternatively��
����you�can�use�the�‘+’�and�‘-’�buttons
03�-�Flash�off
04�-�To�set�the�flash�speed�of�the�LED�either��
����select�20%,�50%�or�100%�or�alternatively��
����you�can�use�the�‘+’�and�‘-’�buttons
05�-�Set�the�LED�into�DMX�mode
06�-�Set�the�LED�into�sound�active�mode
07�-�Set�the�LED�into�slave�mode
08�-�Set�the�DMX�address�for�the�LED
1
2
3
4
5
6
0
+
_
7
8
9
D
SL
S
OFF
20%
50%
100%
SA
STROBE
OFF
20%
50%
100%
DIMMING
SLAVE
SET ADDR
SOUND ACTIVE
DMX MODE
01
04
02
07
06
05
08
Optional
IR remote
Order code:
LEDJ90E
03
Operating instructions
Event Spot DL/WW User Manual
9
Setting the DMX address:
The�DMX�mode�enables�the�use�of�a�universal�DMX�controller.�Each�fixture�requires�a�“start�address”�
from�1-�511.�A�fixture�requiring�one�or�more�channels�for�control�begins�to�read�the�data�on�the�channel�
indicated�by�the�start�address.�For�example,�a�fixture�that�occupies�or�uses�7�channels�of�DMX�and�was�
addressed�to�start�on�DMX�channel�100,�would�read�data�from�channels:�100,101,102,103,104,105�
and�106.�Choose�a�start�address�so�that�the�channels�used�do�not�overlap.�E.g.�the�next�unit�in�the�
chain�starts�at�107.
DMX 512:
DMX�(Digital�Multiplex)�is�a�universal�protocol�used�as�a�form�of�communication�between�intelligent�
fixtures�and�controllers.�A�DMX�controller�sends�DMX�data�instructions�form�the�controller�to�the�fixture.�
DMX�data�is�sent�as�serial�data�that�travels�from�fixture�to�fixture�via�the�DATA�“IN”�and�DATA�“OUT”��
XLR�terminals�located�on�all�DMX�fixtures�(most�controllers�only�have�a�data�“out”�terminal).
DMX linking:
DMX�is�a�language�allowing�all�makes�and�models�of�different�manufactures�to�be�linked�together��
and�operate�from�a�single�controller,�as�long�as�all�fixtures�and�the�controller�are�DMX�compliant.��
To�ensure�proper�DMX�data�transmission,�when�using�several�DMX�fixtures�try�to�use�the�shortest��
cable�path�possible.�The�order�in�which�fixtures�are�connected�in�a�DMX�line�does�not�influence�the��
DMX�addressing.�For�example;�a�fixture�assigned�to�a�DMX�address�of�1�may�be�placed�anywhere�in��
a�DMX�line,�at�the�beginning,�at�the�end,�or�anywhere�in�the�middle.�When�a�fixture�is�assigned�a��
DMX�address�of�1,�the�DMX�controller�knows�to�send�DATA�assigned�to�address�1�to�that�unit,��
no�matter�where�it�is�located�in�the�DMX�chain.
DATA cable (DMX cable) requirements (for DMX operation):
This�fixture�can�be�controlled�via�DMX-512�protocol.�The�DMX�address�is�set�on�the�back�of�the�unit.�
Your�unit�and�your�DMX�controller�require�a�standard�3-pin�XLR�connector�for�data�input/output,��
see�image�below.
Note: DMX cable must be daisy chained and cannot be split.
DMX setup
Further�DMX�cables�can�be�
purchased�from�all�good�sound�
and�lighting�suppliers�or��
Pro�Light�Concepts�dealers.
Please�quote:
CABL10 – 2m
CABL11 – 5m
CABL12 – 10m
Event Spot DL/WW User Manual
10
Notice:
Be�sure�to�follow�the�diagrams�below�when�making�your�own�cables.�Do�not�connect�the�cables��
shield�conductor�to�the�ground�lug�or�allow�the�shield�conductor�to�come�in�contact�with�the�XLRs��
outer�casing.�Grounding�the�shield�could�cause�a�short�circuit�and�erratic�behaviour.
Special note:
Line termination:
When�longer�runs�of�cable�are�used,��
you�may�need�to�use�a�terminator�on��
the�last�unit�to�avoid�erratic�behaviour.
Using a cable terminator will decrease
the possibilities of erratic behaviour.
(3-pin - Order ref: CABL90, 5-pin - Order ref: CABL89)
5-pin XLR DMX connectors:
Some�manufactures�use�5-pin�XLR�connectors�for�data�transmission�in�place�of�3-pin.�5-pin�XLR�fixtures�
may�be�implemented�in�a�3-pin�XLR�DMX�line.�When�inserting�standard�5-pin�XLR�connectors�in�to�a�
3-pin�line�a�cable�adaptor�must�be�used.�The�diagram�below�details�the�correct�cable�conversion.
Termination�reduces�signal�transmission�
problems�and�interference.�It�is�always�
advisable�to�connect�a�DMX�terminal,�
(resistance�120�Ohm�1/4�W)�between�pin�2�
(DMX-)�and�pin�3�(DMX+)�of�the�last�fixture.
5-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
3-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
3-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
5-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
DMX setup
Event Spot DL/WW User Manual
11
WEEE notice
Correct Disposal of this Product
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries
with separate collection systems)
This�marking�shown�on�the�product�or�its�literature,�indicates�that�it�should�not�be�disposed��
with�other�household�wastes�at�the�end�of�its�working�life.�To�prevent�possible�harm�to�the��
environment�or�human�health�from�uncontrolled�waste�disposal,�please�separate�this�from�other�
types�of�wastes�and�recycle�it�responsibly�to�promote�the�sustainable�reuse�of�material�resources.
Household�users�should�contact�either�the�retailer�where�they�purchased�this�product,�or�their�
local�government�office,�for�details�of�where�and�how�they�can�take�this�item�for�environmentally�
safe�recycling.
Business�users�should�contact�their�supplier�and�check�the�terms�and�conditions�of�the��
purchase�contract.�This�product�should�not�be�mixed�with�other�commercial�wastes�for�disposal.