AMX NXA-UPS1500 Installation Manual

Specifications

Brand: AMX
Category: UPS
Model: NXA-UPS1500
File Type: PDF
File Size: 0.32 Mb
Pages: 2

Read Online

Read the AMX NXA-UPS1500 Installation Manual online using the built-in PDF viewer.

Text of the manual

NXA-UPS1500 (120v/240v) Uninterruptible Power Supply

NXA-UPS1500 (120v/240v) UPS The NXA-UPS1500 is a Uninterruptible Power Supply (UPS) featuring Double AVR Boost and Double Buck, Pure Sine Wave Output, LCD Display and Hot-Swappable Battery. The NXA-UPS1500 supports RS232 control. The NXA-UPS1500 is available in two voltages: • 120V (FG678-15) • 240V (FG678-20) The NXA-UPS1500 features tower/rack-convertible design making it ideal for use with AMX’s line of MAX devices (FIG. 1). IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS: This manual contains important safety instructions. Please follow all instructions carefully during installation. Read this manual thoroughly before attempting to unpack, install or operate. CAUTION - To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area, free of conductive contaminants. CAUTION - Risk of electric shock, do not remove the cover. No user serviceable parts. Refer servicing to qualified service personnel. CAUTION - Risk of electric shock, hazardous live parts inside this UPS can be energized from the battery supply even when the input AC power is disconnected. WARNING - This is a Class A-UPS Product. In a domestic environment, this product may cause radio interference, in which case, the user may be required to take additional measures. NOTICE - The UPS is designed to be for use with computer loads only. NOTICE- To prevent injury, do not carry with the handle of front cover when moving the UPS. Front Panel LCD and LEDs FIG. 2 describes the elements of the front panel LCD: DIP Switch Setting The nominal voltage of the UPS can be reset by the DIP Switch on the rear panel of the UPS. The following charts describe the voltage settings. Indicators & Alarms Setup Instructions Connecting the Batteries The UPS1500 ships with the four batteries installed inside the unit. Before use, you will need to connect the main power connector inside the unit: 1. Remove the Release tabs on the front panel (see FIG. 1) to expose the screws that secure the Battery Compartment Cover. 2. Remove the screws beneath the Release tabs (FIG. 4). 3. Remove the Battery Compartment Cover to access the Battery Compartment. 4. Remove the screw holding the metal securing piece in place. 5. Slide the metal securing piece into the groove on the 4-pin connector (red) from the battery cable harness. 6. Connect the 4-pin connector to the matching connector inside the unit. 7. Reattach the metal securing piece above the connector with the screw (FIG. 5). FIG. 1 NXA-UPS1500 Uninterruptible Power Supply NXA-UPS1500 Product Specifications Input: • Voltage Window (DIP Switch selectable): 120V version (FG678-15): 110/115/120 Vac +35% ˜ -32% 240V version (FG678-20): 220/230/240 Vac +35% ˜ -32% • Frequency: 45 ˜ 65Hz (50/60Hz auto-sensing) Output: • Voltage Window (AC Mode): 120V version (FG678-15): 110/115/120 Vac +8% ˜ -12% 240V version (FG678-20): 220/230/240 Vac +8% ˜ -12% • Voltage Window (INV Mode): 120V version (FG678-15): 110/115/120 Vac +/-5% 240V version (FG678-20): 220/230/240 Vac +/-5% • Capacity (VA/W):1500/900 • Wave Form: Pure sine wave • Frequency: 50Hz/60Hz +/-0.1Hz • Transfer Time:2 ms typical • Autonomy: > 8 min. • DC Start: Yes Battery: • Type: 12V, sealed lead acid maintenance-free • Capacity: 9AH • Quantity: 4 12V batteries required • Voltage: 120V version (FG678-15): 24 Vdc 240V version (FG678-20): 48 Vdc • Recharge Time: 2 ˜ 4 hours to 90% • Storage: Store at -15 to +30 °C (+5 to +86 °F), charge the UPS battery every 6 months / Store at +30 to +45 °C (+86 to +113 °F), charge the UPS battery every 3 months. LED indicators: • Utility mode • Backup mode • Battery conditions Display LCD: • Load level (%) • Battery level (%) • Bypass • AVR-Boost/AVR Buck • Battery Low/Replace/Fault • UPS Fault • Site Wiring Fault • Overload Overload Protection: • AC Mode: >110% Buzzer continuously alarms, and shuts down in 10 minutes. • Inverter Mode: >120% Buzzer continuously alarms, and shuts down in 10 seconds. Short Circuit Protection: • AC Mode: Breaker and electronic circuit • Inverter Mode: Shut down automatically in 8 cycles Self-Diagnostics: Upon Power-on Alarms: • Line Failure • Battery Low • Overload and Fault Operation Environment: • Temperature: 32° - 104°F (0-40° C) • Operation Humidity: 95% RH Maximum, non-condensing Dimensions (HWD): • 3.46” x 17.32” x 18.97” (8.80cm x 44.0cm x 48.2 cm) • 2U rack height Control Communication: RS-232 Weight (with batteries): 70.3 lbs (31.89 kg) Certifications: • EN50091-1-1:1996 (Safety) • FCC Part 15, Subpart B - Class A • UL: YEDU.E166979 (front) (rear) Front Panel LCD Battery Compartment RS232 Communication Port DIP Switch USB Communication Port RJ-45 Ports (Network Surge Protection) Power Outlets Output Breaker Input Breaker External Battery Terminal Input Power Socket (Inlet) Release tabs NXA-UPS1500 Product Specifications (Cont.) Included Accessories: • AC Input Power Cord • Tower and rack-mounting accessories Other AMX Equipment: NXA-UPS1500 EPM Extended Power Module (FG 678-16) NXA-UPS1500ECJ, European Power Cable (FG 678-17) NXA-UPS1500UKCJ, United Kingdom Power Cable (FG678-18) NXA-UPS1500ACJ, Australian Power Cable (FG678-19) FIG. 2 Front Panel LCD and LEDs FIG. 3 DIP Switch Settings (sets nominal voltage) Indicator Color Description Alarm Utility Mode Green • Steady: Output Load is supplied by Utility. • Blinking: Polarity error or Ground Fault. None Backup Mode Amber • Steady (with alarm): Output Load is supplied by Battery. • Blinking every 5 seconds (no alarm): Stand by for Utility recovery to re-start up. Every 2 seconds before battery Low and every 1 second before battery Cutoff. Fault Red When Overload, short circuit, or Output Voltage Abnormal occurs. Buzzer beeps continuously Battery Replacement N.A. (LCD) • Blinking: Battery is weak and needs to be recharged. • Steady: Battery is dead. None 1. Utility (Green LED) 2. Fault (Red LED) 3. On Switch 4. Off Switch 5. Battery Replacement 6. Battery Backup (Amber LED) 7. Battery Low 8. Bypass 9. Utility Low, UPS Boost 10. Utility High, UPS Buck 11. UPS Output Indicator 12. Polarity Error or Ground Fault 13. Overload 14. Load/Battery Level (%) 15. Load/Battery Level 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 6 2 Indication Control Button FUNCTION 2 1 VOLTAGE=110V VOLTAGE=115V VOLTAGE=120V ON OFF OFF OFF OFF ON FUNCTION 2 1 VOLTAGE=220V VOLTAGE=230V VOLTAGE=240V ON OFF OFF OFF OFF ON 120V (FG678-15) 240V (FG678-20)

For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).

12/08 ©2008 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX. AMX reserves the right to alter specifications without notice at any time. 3000 RESEARCH DRIVE, RICHARDSON, TX 75082 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993 • www.amx.com 93-0678-30 REV: D Place The UPS Properly It is necessary to select a proper environment to install the unit, in order to minimize the possibility of damage to the UPS and extend the life of the UPS. • Keep at least 20cm (8") clearance from the rear panel of the UPS from the wall or other obstructions. • Do not block the air-flow to the ventilation openings of the unit. • Ensure that the installation site environmental conditions are in accordance with the UPS working specifications to avoid overheat and excessive moisture. • Do not place the UPS in a dusty or corrosive environment or near any flammable objects. • This UPS is not designed for outdoor use. Setup IMPORTANT: Plug the UPS onto the wall receptacle to charge the UPS for over 8 hours after initial installation. Initial Battery Charge (required before first use) IMPORTANT: Plug the UPS onto the wall receptacle to charge the UPS for over 8 hours after initial installation. Plug-In Charge If the Input Power Cord is connected to the wall receptacle properly and the utility is normal, the UPS will start charging automatically without processing “Turn On” procedure. Note: Charge the batteries for at least 8 hours every 3 months when the UPS is in an idle condition. Connect Utility and Load First, connect the UPS with Utility, then plug the loads into the Outlets on the rear of the UPS (FIG. 6). To use the UPS as a master “On/Off” switch, make sure that all of the loads are switched “on”. These UPS outlets provide battery backup and surge protection to the equipment when Utility voltage is out of window. Caution: Do not connect a laser printer to the UPS outlets. Connect Network Surge Protection Connect a 10 base-T / 100 base-T network cable with the RJ-45 network surge protection “IN” jack on the rear of the UPS. Connect from the “OUT” jack with network cabling to network equipment (FIG. 7). NOTE: If using the NXA-UPS1500 as part of a MAX system, do not run the A/V segment of the network through the RJ45 network surge protection jack on the UPS. The A/V segment of a MAX network requires a GB Ethernet switch, and the NXA-UPS1500 only provides a 10/100 connection. You can connect the Control segment of the MAX network to the UPS, since it does not require a GB connection to operate properly. Connect the RS-232 Communication Port Connect the supplied RS-232 interface cable between the RS-232 port on the rear of the UPS and an available RS-232 port on the NetLinx Master (FIG. 8). RS-232 Communication Port Pin Assignment The NXA-UPS1500 provides a DB9F (9-pin female) connector to communicate via RS-232. The pinout configuration for the RS-232 Communication Port connector is shown in FIG. 9: Operation Turn On the UPS 1. Connect the UPS to the wall receptacle. LCD will display “OFF”, when Utility is nor- mal. If there is nothing on the LCD, go to step 3. 2. Push the “On” Switch on the front panel to start the UPS. Both the LCD and Utility LED (Green) are lit. The start-up procedure is completed and the loads are supplied by the UPS. To cold start the UPS, press the “On” Switch on the front panel for approximately 3 seconds until the LCD lights up and buzzer sounds, then release the “On” Switch. The UPS starts operating and Battery Backup LED (Amber) lights up. The cold start- up procedure is completed and the loads are supplied by the UPS. The UPS will run under Backup mode and the buzzer alarms every 2 seconds in case of blackout or over/under voltage. On the contrary, If Utility is back to normal and then the UPS will run under Utility mode and silence alarm. CAUTION: The UPS will remain at “NO” output, if the start-up operation is not proceeded properly even though the Input Power Cord is connected to the wall receptacle. Turn Off the UPS 1. Press the “Off” Switch for at least 3 seconds to turn off the UPS. In some occasions, the UPS will shut itself down in case of overload, output short- circuited or battery cutoff point reached in the Backup mode. 2. The UPS will automatically shut off the output and beep for 5 seconds then completely shut itself down. FIG. 4 Remove the two screws that secure the Battery Compartment Cover FIG. 5 Remove the metal securing piece, connect it to the battery cable harness, and connect the harness to the matching connector inside the unit. FIG. 6 Connect Utility and Load 4-pin connector from the battery wiring harness 4-pin connector power connector inside the enclosure Metal securing piece NetLinx / MAX Equipment Touch Panels UPS FIG. 7 Connect Network Surge Protection FIG. 8 Connect RS-232 Communication Port FIG. 9 RS-232 Communication Port Pin Assignment To Network Network Equipment OUT IN (Network Surge Protection) 5 4 3 2 1 9 8 7 6 (Male) NetLinx (Female) 5 4 3 2 1 9 8 7 6 UPS Pin 2: TX signal Pin 3: RX signal Pin 5: GND Pin 2: RX signal Pin 3: TX signal Pin 5: GND RX (Pin 2) TX (Pin 3) GND (Pin 5) TX (Pin 2) RX (Pin 3) GND (Pin 5)

Other UPS Manuals