AMX Limited Warranty and Disclaimer

AMX Corporation warrants its products to be free of defects in material and workmanship under normal use for three (3) years from the date of purchase from AMX Corporation, with the following exceptions: • Electroluminescent and LCD Control Panels are warranted for three (3) years, except for the display and touch overlay components that are warranted for a period of one (1) year. • Disk drive mechanisms, pan/tilt heads, power supplies, and MX Series products are warranted for a period of one (1) year. • AMX Lighting products are guaranteed to switch on and off any load that is properly connected to our lighting products, as long as the AMX Lighting products are under warranty. AMX Corporation does guarantee the control of dimmable loads that are properly connected to our lighting products. The dimming performance or quality cannot be guaranteed due to the random combinations of dimmers, lamps and ballasts or transformers. • Unless otherwise specified, OEM and custom products are warranted for a period of one (1) year. • AMX Software is warranted for a period of ninety (90) days. • Batteries and incandescent lamps are not covered under the warranty. This warranty extends only to products purchased directly from AMX Corporation or an Authorized AMX Dealer. All products returned to AMX require a Return Material Authorization (RMA) number. The RMA number is obtained from the AMX RMA Department. The RMA number must be clearly marked on the outside of each box. The RMA is valid for a 30-day period. After the 30-day period the RMA will be cancelled. Any shipments received not consistent with the RMA, or after the RMA is cancelled, will be refused. AMX is not responsible for products returned without a valid RMA number. AMX Corporation is not liable for any damages caused by its products or for the failure of its products to perform. This includes any lost profits, lost savings, incidental damages, or consequential damages. AMX Corporation is not liable for any claim made by a third party or by an AMX Dealer for a third party. This limitation of liability applies whether damages are sought, or a claim is made, under this warranty or as a tort claim (including negligence and strict product liability), a contract claim, or any other claim. This limitation of liability cannot be waived or amended by any person. This limitation of liability will be effective even if AMX Corporation or an authorized representative of AMX Corporation has been advised of the possibility of any such damages. This limitation of liability, however, will not apply to claims for personal injury. Some states do not allow a limitation of how long an implied warranty last. Some states do not allow the limitation or exclusion of incidental or consequential damages for consumer products. In such states, the limitation or exclusion of the Limited Warranty may not apply. This Limited Warranty gives the owner specific legal rights. The owner may also have other rights that vary from state to state. The owner is advised to consult applicable state laws for full determination of rights. EXCEPT AS EXPRESSLY SET FORTH IN THIS WARRANTY, AMX CORPORATION MAKES NO OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. AMX CORPORATION EXPRESSLY DISCLAIMS ALL WARRANTIES NOT STATED IN THIS LIMITED WARRANTY. ANY IMPLIED WARRANTIES THAT MAY BE IMPOSED BY LAW ARE LIMITED TO THE TERMS OF THIS LIMITED WARRANTY.

Table of Contents

i AXB-TC and AXB-TCR Television Controllers Table of Contents Product Information .................................................................................................1 Specifications .................................................................................................................... 2 Applications....................................................................................................................... 3 Installation and Wiring .............................................................................................5 Setting the Device DIP Switch........................................................................................... 5 Internal Jumper Settings ................................................................................................... 5 JI jumper settings: TV power sensing/TV power current sensing mode .................................. 6 J2 jumper settings: IR output mode (IR or serial communication) ........................................... 6 J3 jumper settings: IR attenuation mode (bypass or adjustment)............................................ 6 Wiring ................................................................................................................................ 7 Wiring guidelines...................................................................................................................... 7 Preparing/connecting captive wires ......................................................................................... 7 TV Sensor connections............................................................................................................ 7 IR Emitter connections............................................................................................................. 8 Axlink data and power connections.......................................................................................... 8 Axlink data and 12 VDC power supply connections................................................................. 8 PCS and Axlink data and power connections .......................................................................... 9 PCS and 12 VDC power supply connections........................................................................... 9 Installation ....................................................................................................................... 10 Television Power Sensor Adjustment.............................................................................. 11 IR Signal Attenuation Adjustment.................................................................................... 11 Replacing the Lithium Battery ......................................................................................... 12 Programming Information .....................................................................................15 Channel Setting Commands ........................................................................................... 15 IR Functions (Standard Order)........................................................................................ 16 Send_Commands............................................................................................................ 17 Firmware Upgrades......................................................................................................... 21 Using SOFTROM................................................................................................................... 21 Using NetLinx Studio.............................................................................................................. 22

AXB-TC and AXB-TCR Television Controllers

Product Information The AXB-TC and AXB-TCR Television Controllers are intelligent, microprocessor-controlled systems equipped with a lithium battery to protect stored memory. The television controllers can control a variety of Infrared-controlled devices such as televisions, audio receivers, and videocassette recorders. FIG. 1 shows the front and rear panels of the AXB-TCR. With the exception of the IR Input Window (on the AXB-TCR only), the TC and TCR share the same front and rear panel components. FIG. 1 AXB-TCR front and rear panel components AXlink PWR IR OUT TV SENSOR AXlink DEVICE ON IR Input Window IR Out LED TV Sensor LED AXlink LED Device DIP switch PWR connector AXlink connector IR Emitter connector TV Sensor connector Front Rear TV Power Sensing POT

AXB-TC and AXB-TCR Television Controllers

Specifications The following table list the product specifications for the television controllers. Other than the IR Input Window (on the AXB-TCR only), the specifications for the TC and TCR are identical. AXB-TC/TCR Specifications Dimensions (HWD): (with connectors) • 1.29" x 3.33" x 5.54" (32.8 mm x 84.6 mm x 140.6 mm) Power consumption: 200 mA @ 12 VDC Front Panel Components: LED indicators • AXlink LED (green and blinks to indicate AXlink communication activity and power: • Full-Off indicates no power is being received or the controller is not functioning properly. • One blink per second indicates power is active and AXlink communication is functioning. • Full-On indicates there is no AXlink control or activity, but power is On. IR Out: Red LED blinks when the television controller transmits IR or serial (outgoing) signals. One blink every 2 seconds: The AXB-TC/TCR program is not loaded. TV Sensor: Red LED that lights when the television controller receives, via the CC-IR TV Sensor, the correct horizontal scan frequency signal indicating television or monitor power is on. This LED also lights when the television controller receives a power on status from an AMX PCS Power Control Sensor. One blink every 2 seconds: The AXB-TC/TCR program is not loaded DEVICE DIP switch 8-position DIP switch that sets the AXlink device number on the AXB-TC and AXB-TCR. IR Input Window (AXB-TCR only) Receives 38 kHz IR-control signals from AMX transmitters. The IR input window contains a red LED that lights when receiving IR- control data. IR Compatibility (AXB-TCR only) AMX wireless IR control panels and hand-held transmitters (38 kHz only) Rear Panel components: TV Sensor connector 2-pin (male) connector that supports horizontal scan frequency sensing up to 65 kHz with a CC-IR TV Sensor. The connector can also be used with a PCS (Power Current Sensor) to detect television power status (on or off). TV Sensor POT Sets the sensitivity to the PCS. You may need to adjust this POT to allow the PCS to detect the television's power status (on or off). IR Emitter connector 2-pin (male) connector that transmits IR control signals to a television using the CC-IRC IR Emitter cables. The connector also supports trans- mitting serial control data to an external device. AXlink connector 4-pin (male) connector that supports AXlink control data communication. PWR connector 2-pin (male) connector that connects to an external 12 VDC power sup- ply. Refer to the Wiring section on page 7 for external power supply requirements. Enclosure: Plastic with black matte finish Weight: 6 oz. (170 grams)

AXB-TC and AXB-TCR Television Controllers

Applications FIG. 2 shows a sample system configuration. AXB-TC/TCR Specifications (Cont.) Mounting options: Flat surface Included accessories: • CC-IR TV Sensor (CC-XPS sensor) • CC-IRC IR Emitter Optional accessories: • SE-TC Security Enclosure • PCS Power Current Sensor • VSS2 Video Sync Sensor • 12 VDC Power supply FIG. 2 Sample system application Power Supply Television PCS CC-IR CC-IRC AXB-TC AXB-TCR Axcess Cardframe (rear view) TXC-16 Television transmitter Power Control Sensor TV Sensor/cable AXlink AXlink Power Supply IR Emitter/cable IR signal

Installation and Wiring

5 AXB-TC and AXB-TCR Television Controllers Installation and Wiring Setting the Device DIP Switch The eight-position Device DIP switch sets the identification number for the television controller. Make sure the device number matches the number assigned in the AXCESS software program. The quick reference table below shows the switch positions and their numeric value. In the example below, the numeric value of the Device DIP switch is 97 (1+32+64=97). Internal Jumper Settings The internal jumpers, located on the circuit card inside the television controller enclosure, set the input, output, and IR attenuation modes. Internal jumper modes include: ! Jumper JP1 sets the input mode for power sensing or power current sensing. ! Jumper JP2 sets the IR output mode for IR or serial communication. ! Jumper JP3 sets the IR attenuation mode for bypass or adjustment. Use a Phillips-head screwdriver to open the enclosure and non-conducting pliers to set the jumpers. 1. Unplug all connectors from the rear panel of the television controller. 2. Remove the two Phillips-head screws on the bottom of the enclosure. 3. Pull the two enclosure halves apart and set the bottom portion of the enclosure on a flat surface. FIG. 3 shows the location of the internal jumpers. DIP Switch Settings Switch 1 2 3 4 5 6 7 8 Value 1 2 4 8 16 32 64 128 Static electricity can damage electronic circuitry. Before removing the enclosure, discharge any accumulated static electricity from your body by touching a grounded metal object. FIG. 3 Internal jumper locations JP1 jumper JP3 jumper JP2 jumper front 1 2 3 4 5 6 7 8 ON DEVICE

Installation and Wiring

6 AXB-TC and AXB-TCR Television Controllers 4. Replace the top portion of the enclosure on the bottom portion. Then, refasten the two Phillips- head screws. JI jumper settings: TV power sensing/TV power current sensing mode J2 jumper settings: IR output mode (IR or serial communication) J3 jumper settings: IR attenuation mode (bypass or adjustment) JI Jumper Settings: TV Power Sensing/TV Power Current Sensing Television Power (on or off) Sensing mode To use this mode, connect a CC-IRC to the television to detect horizontal scan frequen- cies up to 65 kHz. Place the 2-pin jumper on the JP1 connector pin's 1 and 2. Television Power Current Sensing mode To use this mode, connect a PCS Power Current Sensor to the television to detect on and off power status. Place the 2-pin jumper on the JP1 connector pin's 2 and 3. Refer to the PCS Power Current Sensor instruction manual for additional control information. J2 Jumper Settings: IR Output Mode (IR or Serial Communication) IR Output mode To use this mode, connect a CC-IRC IR Emitter to the television to transmit IR sig- nals. Place the 2-pin jumper on the JP2 con- nector pin's 2 and 3. Serial (wired connection) Output mode Place the 2-pin jumper on the JP2 connector pin's 1 and 2. J3 Jumper Settings: IR Attenuation Mode (Bypass or Adjustment) IR Signal Attenuation Bypass mode (normal) Place the 2-pin jumper on the JP3 connector pin's 1 and 2. IR Signal Attenuation Adjustment mode Place the 2-pin jumper on the JP3 connector pin's 2 and 3. Also, set the JP2 internal jumper for IR emit- ter mode.

Installation and Wiring

7 AXB-TC and AXB-TCR Television Controllers Wiring The TV sensor, IR emitter, AXlink, and 12 VDC power supply connectors are located on the rear panel of the television controller as shown in FIG. 1 on page 1. Wiring guidelines The television controller requires 12 VDC power to operate properly. The power can be supplied via AXlink cable, or with an optional 12 VDC power supply. The maximum wiring distance between the Central Controller and television controller is determined by power consumption, supplied voltage, and the wire gauge used for the cable. The following table lists wire sizes and the maximum lengths allowable between the television controller and Central Controller. The maximum wiring lengths are based on a minimum of 13.5 volts available at the Central Controller's power supply. If a television controller is installed farther away from the Central Controller than recommended in the table, connect a 12 VDC power supply to the 2-pin 12 VDC PWR connector on the rear panel. Preparing/connecting captive wires 1. Strip 0.25 inch of wire insulation off all wires. 2. Insert each wire into the appropriate opening on the connector according to the wiring diagrams and connector types described in this section. Do not tighten the screws excessively; doing so may strip the threads and damage the connector. TV Sensor connections Connect the CC-IR to the TV Sensor connector, on the rear panel of the television controller, as shown in FIG. 4 to detect horizontal scan frequencies up to 65 kHz. Do not connect power directly to the television controller. If you are using power from AXlink, disconnect the wiring from the Central Controller before connecting the wiring to the television controller. If you are using an optional 12 VDC power supply, apply power to the television controller only when installation is complete. Wiring Guidelines - TC - 175 mA Wiring Guidelines - TCR - 200 mA Wire size Maximum wiring length Wire size Maximum wiring length 18 AWG 670.69 feet (204.43 meters) 18 AWG 586.55 feet (178.78 meters) 20 AWG 424.33 feet (129.34 meters) 20 AWG 371.29 feet (113.17 meters) 22 AWG 264.55 feet (80.63 meters) 22 AWG 231.48 feet (70.56 meters) 24 AWG 166.76 feet (50.83 meters) 24 AWG 145.91 feet (44.47 meters) FIG. 4 CC-IR TV Sensor connector wiring diagram TV SENSOR connector GND SEN CC-IR Television

Installation and Wiring

8 AXB-TC and AXB-TCR Television Controllers IR Emitter connections Connect the CC-IRC IR Emitter to the IR Emitter connector, on the rear panel of the television controller (FIG. 5) to transmit IR control signals to the television. Axlink data and power connections Connect the Central Controllers's AXlink connector to the AXlink connector on the rear panel of the television controller for data and 12 VDC power, as shown in FIG. 6. Axlink data and 12 VDC power supply connections Connect the Central Controller’s AXlink connector to the AXlink connector on the rear panel of the television controller, and the optional 12 VDC power supply, as shown in FIG. 7. FIG. 5 CC-IRC IR Emitter connector wiring diagram FIG. 6 AXlink data and power wiring diagram FIG. 7 AXlink Data and 12 VDC Power Supply Connections IR EMITTER connector GND SG CC-IRC Television 12 VDC no connection Axcess Control System AXlink connector PWR GND PWR AXP AXM GND PWR AXP AXM GND PWR connector 12 VDC 12 VDC power supply Axcess Control System AXlink connector PWR GND PWR AXP AXM GND PWR AXP AXM GND PWR connector

Installation and Wiring

9 AXB-TC and AXB-TCR Television Controllers Use the 12 VDC power supply when the distance between the AMX system and television controller exceeds the limits described in the Wiring Guidelines table on page 7. PCS and Axlink data and power connections Connect the PCS Power Current Sensor to the TV Sensor connector, on the rear panel of the television controller (FIG. 8) to detect and control the television power status (on or off). PCS and 12 VDC power supply connections Connect the PCS to the TV Sensor connector, on the rear panel of the television controller, and the optional 12 VDC power supply, as shown in FIG. 9, to detect and control the television power status (on or off). Make sure to connect only the GND wire on the AXlink connector when using a 12 VDC power supply. Do not connect the PWR wire to the AXlink connector's PWR opening. FIG. 8 PCS and AXlink data and power wiring diagram FIG. 9 PCS and optional 12 VDC power supply wiring diagram PWR AXP AXM GND PWR AXP AXM GND GND PWR SEN GND no connection PCS Power Supply Sensor 12 VDC AXlink TV SENSOR Television Controller connector connector connector PWR AXP AXM GND PWR AXP AXM GND GND PWR SEN GND PCS Power Supply Sensor 12 VDC AXlink TV SENSOR Television Controller connector connector connector GND PWR 12 VDC power supply

Installation and Wiring

10 AXB-TC and AXB-TCR Television Controllers Installation Install the television controller on any flat surface or inside the optional SE-TC Security Enclosure, as described below: 1. Mount the Axcess Central Controller where it will be used. Then, connect the power supply. 2. Route the Axlink power and data cable, CC-IR TV Sensor cable, CC-IRC IR Emitter cable, and 12 VDC power supply from the television to the television controller's location. 3. Drill four #6-32 holes into the SE-TC mounting surface in the locations shown in FIG. 10. 4. Mount the SE-TC. FIG. 10 SE-TC mounting dimensions

Installation and Wiring

11 AXB-TC and AXB-TCR Television Controllers Television Power Sensor Adjustment After connecting the CC-IR to the television, the power sensing POT, on the rear of the television controller (see FIG. 1 on page 1), may require adjustment to detect the television's power status: Use a Phillips-head screwdriver and flat-blade tool (non-conducting) to adjust the POT screw. 1. Turn the television off. 2. Locate the POT screw on the circuit card and turn it clockwise 20 full turns or until it clicks. The red TV Sensor indicator, located on the front panel, should be dark. 3. Turn the television on. 4. Turn the POT screw counterclockwise until the TV Sensor indicator lights. Then, turn the POT screw counterclockwise one full turn. 5. Turn television power off. If the TV Sensor indicator is lit, turn the POT screw clockwise until the indicator goes dark. 6. Reattach the enclosure and refasten the two screws. IR Signal Attenuation Adjustment If you experience television control problems after connecting a CC-IRC IR Emitter to the television, the television may be too sensitive to interpret the IR signals generated by the television controller. You can use the IR signal attenuation POT, located inside the television controller (FIG. 11), to decrease the strength of the IR signal. Refer to Internal Jumper Settings section on page 5 to put the AXB-TC or AXB-TCR in IR attenuation mode. Use a Phillips-head screwdriver and flat-blade tool (non-conducting) to adjust the POT screw. FIG. 11 IR signal attenuation POT location front IR signal attenuation POT Static electricity can damage electronic circuitry. Discharge any static electricity from your body by touching a grounded metal object before adjusting the POT.

Installation and Wiring

12 AXB-TC and AXB-TCR Television Controllers 1. Remove the two Phillips-head screws on the bottom of the television controller enclosure. 2. Pull the two enclosure halves apart and set the bottom portion of the enclosure on a flat surface. 3. Locate the POT screw on the circuit card and turn it counterclockwise with a flat-blade tool until it stops. 4. Turn the POT screw clockwise one-eighth turn to increase signal saturation. Then, send an IR control signal to the television. If the television performs correctly, go to step 5. If not, repeat this step until the television performs the correct operation. 5. Send an IR control signal to the television for all programmed operations. If an operation fails, go back to step 4. 6. Reattach the enclosure and refasten the two screws. Replacing the Lithium Battery There is a lithium battery (FIG. 12), with a life of approximately five years, in the television controller that protects stored presets if there is a power loss. The battery is not used when DC power is supplied to the television controller. You should write down the replacement date on a sticker or label by adding 5 years to the date of installation, and attach it to the bottom of the television controller. Contact your AMX dealer before you replace the lithium battery to verify that they have a current copy of the IRLIB program file for your television controller. This will prevent any inadvertent loss of data or service outage. Use a flat-blade tool (non-conducting) that can be slipped under the lithium battery to pry it up and out of the socket. 1. Discharge the static electricity from your body. 2. Unplug all cables from the television controller. 3. Remove the two Phillips-head screws on the bottom of the television controller enclosure. 4. Pull the two enclosure halves apart and set the bottom portion of the enclosure on a flat surface. 5. Locate the battery on the circuit card. FIG. 12 Lithium battery and socket Battery (CR2025 type) socket All control commands in television controller memory are lost when the lithium battery is replaced. Static electricity can damage electronic circuitry. Before removing the battery from the enclosure, discharge any static electricity from your body by touching a grounded metal object.

Installation and Wiring

13 AXB-TC and AXB-TCR Television Controllers 6. Carefully pry the battery out of its socket and insert the new battery. Write down the next replacement date on a label by adding 5 years to the replacement date; attach it to the bottom of the television controller. 7. Reattach the enclosure and refasten the two screws. 8. Plug all cables back into the television controllers. There is a danger of explosion if you replace the battery incorrectly. Replace the battery with the same or equivalent type, recommended by the manufacturer. Dispose of the used battery according to the manufacturer's instructions. Never recharge, disassemble, or heat the battery above 212 °F (100 °C). Never solder directly to the battery or expose the contents of the battery to water.

AXB-TC and AXB-TCR Television Controllers

Programming Information The television controllers are controlled with channel settings, IR functions, and Axcess Send_Commands. You create software programs with the AMX Axcess programming software. Use the programming information in this section with the Axcess Programming Guide to program television controllers. After you create the IRLIB program, download it to the non-volatile (battery protected) memory in the television controller. Refer to the IRLIB Infrared Library Management Program instruction manual to create and store IR control files. Channel Setting Commands Use the channel setting commands listed in the following table to generate IR code, PUSH and RELEASE operations, and to detect power failure errors. Channel Setting Commands Channel Description 1-127 Channels that generate IR code for the corresponding functions. 128-247 PUSH and RELEASE channels for received IR code. 248 A PUSH on this channel generates a power failure error. 249 Red IR sensor (AXB-TCR only) LED blinks when channel 249 and 250 are on. 250 Red IR sensor (AXB-TCR only) LED lights when channel is on. 255 Channel is on, when the television power sensor (CC-IR) detects a horizontal scan frequency. The channel is disabled after the television controller receives a 'POF' (power off) or 'PON' (power on) command. The channel is enabled after the television controller receives a 'POD' (disable 'PON' or 'POF') command. If one of these channels is turned on while another is already on, the initial channel stops transmitting and the second channel begins.

AXB-TC and AXB-TCR Television Controllers

IR Functions (Standard Order) The following table lists the IR function, in their standard order. IR Functions (Standard Order) Function Description Function Description 1 play > 22 channel up or + 2 stop [] 23 channel down or - 3 pause | | or still 24 volume up or + 4 ffwd >> 25 volume down or - 5 rewind << 26 mute 6 search fwd >>| (AMS music search fwd for CD) 27 on (power typically) 7 search rev |<< (AMS music search rev for CD) 28 off (power typically) 8 record 29 TV/Video, TV/VCR, or TV/LDP (one button source selection) 9 power or on/off 30 TV 10 '0 ' or '10 ' 31 Video1, Line A, VCR1, VDP, or input + 11 '1 ' (channel digits or tracks for CD) 32 Video2, Line B, VCR2, or input - 12 '2 ' 33 Video3 13 '3 ' 34 RGB1 or Tape1 14 '4 ' 35 RGB2 or Tape2 15 '5 ' 36 CD 16 '6 ' 37 tuner 17 '7 ' 38 phono 18 '8 ' 39 aux 19 '9 ' 40 AM/FM 20 '+10 ' (for CD players typically) 41 play < (play reverse) 21 enter (typically used in conjunction with num- bers) 42 A/B

AXB-TC and AXB-TCR Television Controllers

Send_Commands Use the Send_Commands listed in the following table to program the Axcess Central Controller and television controller. ! The device number range for the television controller is 1 through 255. ! Refer to the Axcess Programming Language instruction manual for additional programming information. Send_Commands CARON Enables an IR carrier signal after receiving a 'CARON' command. Example: SEND_COMMAND 1,'CARON' Enables the carrier signal for device 1. CAROFF Disables an IR carrier signal from responding until a 'CARON' command is received. Use this command to control television controllers via serial communication. Example: SEND_COMMAND 255,'CAROFF' Disables the carrier signal for device 255. 'CH', Generates IR digit pulses to select a television channel number. Chan- nels 1-99 pulse as two digits. Channels 100 and greater, the one-hun- dredth digit pulses as 127. If IR function 21 (enter) exists, it follows the IR digit pulses. Variable: = 0-199 Example: SEND_COMMAND 2,"'CH',25" Sets the television connected to device 2 to channel 25. 'CTOF',

AXB-TC and AXB-TCR Television Controllers

Send_Commands (Cont.) ?CTON Sends the current on-time pulse string "'CTON',

AXB-TC and AXB-TCR Television Controllers

Send_Commands (Cont.) 'PTOF',

AXB-TC and AXB-TCR Television Controllers

Send_Commands (Cont.) XCHM Changes the IR output pattern for the XCH command. Syntax: SEND_COMMAND ,'XCH-' Variable: Mode = 0-4 Example: SEND_COMMAND IR_1,'XCH 3' Sets the IR_1 device's extended channel command to mode 3. Mode 0 Example (default): [x] [x] SEND_COMMAND IR_1, 'XCH 3' Transmits the IR code as 3-enter. SEND_COMMAND IR_1, 'XCH 34' Transmits the IR code as 3-4-enter. SEND_COMMAND IR_1, 'XCH 343' Transmits the IR code as 3-4-3-enter. Mode 1 Example: SEND_COMMAND IR_1, 'XCH 3' Transmits the IR code as 0-0-3-enter. SEND_COMMAND IR_1, 'XCH 34' Transmits the IR code as 0-3-4-enter. SEND_COMMAND IR_1, 'XCH 343' Transmits the IR code as 3-4-3-enter. Mode 2 Example: SEND_COMMAND IR_1, 'XCH 3' Transmits the IR code as 0-0-3. SEND_COMMAND IR_1, 'XCH 34' Transmits the IR code as 0-3-4. SEND_COMMAND IR_1, 'XCH 343' Transmits the IR code as 3-4-3. Mode 3 Example: [[100][100]…] SEND_COMMAND IR_1, 'XCH 3' Transmits the IR code as 0-3. SEND_COMMAND IR_1, 'XCH 34' Transmits the IR code as 3-4. SEND_COMMAND IR_1, 'XCH 343' Transmits the IR code as 100-100-100-4-3. XCH Transmit the IR code in the format set with the XCHM mode command. Syntax: SEND_COMMAND ,'XCH ' Variable: = 0 through 999

AXB-TC and AXB-TCR Television Controllers

Firmware Upgrades Firmware upgrades allow you to install the latest available operating system for your AXB-TC or AXB-TCR. The firmware reload is required anytime the unit's LEDs all flash at the same rate as the AXlink LED, or if all LEDs are full-on. To accomplish the upgrade, your computer must be connected to the Axcess Master Controller via a serial (RS-232) interface connecting to the AXlink DB-9 programming port input. There are two ways to upgrade the firmware to an Axcess device: via the DOS-based SOFTROM application, or via the NetLinx Studio program. Both are included on the AMX Software Control Disc. Using SOFTROM To be able to download new firmware, the communications settings must be set by following the steps below. 1. Press F1 and the CONFIGURE BAUD RATE window appears (FIG. 13). 2. Using the up/down arrow keys, select the communications port you are using to interface with the Central Controller and press Enter. 3. Using the right arrow key, move to the BAUD RATE column. Then use the up/down arrow keys to select the interface communications speed. Make sure that the BAUD RATE selections match the settings on the Axcess System Master Controller. 4. Press Enter. 5. Press F10 to save the selected setting and to exit the CONFIGURE screen. After establishing the communications configuration, upgrade firmware as follows: 1. Press F5 to acquire the list of online programmable devices. 2. Using the up/down arrow keys, select your firmware version(s) listed in the Firmware column of the screen and press Enter. 3. Using the Tab key, switch to the ONLINE PANELS list. 4. Using the up/down arrow keys, select the device(s) to be programmed. Press Enter for each device as it is selected. FIG. 13 CONFIGURE BAUD RATE window

AXB-TC and AXB-TCR Television Controllers

5. Press F4 to program the selected device(s), the loading status bar in FIG. 14 then appears. 6. Press F5 to refresh the screen. Verify that all selected panels have the correct firmware version. If any devices still indicated the old version, repeat preceding steps 3 through 5 until all panels indicate the correct firmware version. 7. Upon completion of the upgrade, press F10 to exit SOFTROM. Firmware can be downloaded to multiple device numbers automatically. If multiple devices are selected, the bottom half of the loading bar will indicate the percentage complete for the selected devices. Using NetLinx Studio You can perform firmware upgrades for both Axcess and NetLinx devices using the options in the Firmware sub-menu. Axcess Master Controllers use .TSK files for firmware upgrades. 1. Choose Tools > Firmware > Axcess Firmware to open the Axcess Firmware Download dialog. 2. Adjust the Comm Settings, if necessary: a. Click Settings to open the Communication Setting dialog. b. Select the Communications Port to use. c. Click OK to accept the changes and return to the Axcess Firmware Download dialog. F2 can be pressed to select all ONLINE PANEL devices and F3 can be pressed to clear all devices. FIG. 14 Loading status bar Firmware Device Number Version Number Type Number Loading status and device number

AXB-TC and AXB-TCR Television Controllers

3. Click Browse to navigate to the directory containing the firmware file(s). Once a directory containing one or more .TSK files is specified, a list of available .TSK files is displayed in the upper table in this dialog. 4. Select the desired .TSK file from the list. 5. Click Query Online Devices to populate the on-line device list. 6. Select the target AXlink device from the list of online devices in the lower table. 7. Click Download to open the Confirm Communication Settings dialog, where you can review and confirm your Comm Settings and Target Device information before the download begins. ! Click Cancel to return to the Select Axcess Firmware File dialog, to edit these settings (if necessary). ! Click OK to confirm the Comm Settings and Target Device information, and download the selected .TSK file to the specified Master, on the selected communications port. 8. The File Transfer dialog shows the progress of the download. Click Cancel to cancel the download. 9. Once the .TSK file has been downloaded, the program prompts you to reboot the Axcess Master. Click Yes to reboot, and the program initiates the reboot sequence. When the Master has rebooted, the Status LED on the front panel of the Master blinks once a second to indicate it is functioning properly. 10. Once it has rebooted, click OK.

AMX reserves the right to alter specifications without notice at any time.

032-004-1213 7/03 ©2003 AMX Corporation. All rights reserved. AMX, the AMX logo, the building icon, the home icon, and the light bulb icon are all trademarks of AMX Corporation. AMX reserves the right to alter specifications without notice at any time. *In Canada doing business as Panja Inc. ARGENTINA • AUSTRALIA • BELGIUM • BRAZIL • CANADA • CHINA • ENGLAND • FRANCE • GERMANY • GREECE • HONG KONG • INDIA • INDONESIA • ITALY • JAPAN LEBANON • MALAYSIA • MEXICO • NETHERLANDS • NEW ZEALAND • PHILIPPINES • PORTUGAL • RUSSIA • SINGAPORE • SPAIN • SWITZERLAND • THAILAND • TURKEY • USA ATLANTA • BOSTON • CHICAGO • CLEVELAND • DALLAS • DENVER • INDIANAPOLIS • LOS ANGELES • MINNEAPOLIS • PHILADELPHIA • PHOENIX • PORTLAND • SPOKANE • TAMPA 3000 RESEARCH DRIVE, RICHARDSON, TX 75082 USA • 800.222.0193 • 469.624.8000 • 469-624-7153 fax • 800.932.6993 technical support • www.amx.com