DEVA Broadcast DB90-RX Maintenance And Operation Instruction Manual
Text of the manual
Introduction ........................................................................................................................................ 4
Typographic conventions .................................................................................................................. 5
General Information .......................................................................................................................... 6
Application ...................................................................................................................................... 6
Product Features ............................................................................................................................. 7
Technical Specifications .................................................................................................................. 8
Block Diagram ................................................................................................................................ 9
Safety Precautions ............................................................................................................................ 10
Panel Indicators and Appointments ............................................................................................... 11
Front View ..................................................................................................................................... 11
Rear View ...................................................................................................................................... 12
Connecting of DB90-RX ................................................................................................................. 13
Analog Audio Outputs .................................................................................................................. 13
Digital Audio Output .................................................................................................................... 13
LAN Port ....................................................................................................................................... 13
Operation .......................................................................................................................................... 14
Status ............................................................................................................................................. 16
DB90-RX Configuration ............................................................................................................... 18
Applying New Settings ............................................................................................................. 18
Network Settings ....................................................................................................................... 18
Web Server Settings .................................................................................................................. 19
SNMP Settings .......................................................................................................................... 19
Other Settings .......................................................................................................................... 19
IP Audio Settings ..................................................................................................................... 20
Analog Audio Output Settings .................................................................................................. 20
Audio Source Switching ............................................................................................................ 21
Factory Defaults Settings ............................................................................................................. 22
Stream Default Settings ............................................................................................................ 23
Network Default Settings .......................................................................................................... 23
WEB Server Default Settings ................................................................................................... 23
SNMP Default Settings ............................................................................................................. 23
Other Default Settings ............................................................................................................. 23
Hardware Reset ............................................................................................................................. 24
Network Default Settings .......................................................................................................... 24
WEB Server Default Settings .................................................................................................... 24
Rebooting ..................................................................................................................................... 25
Firmware Update ......................................................................................................................... 26
UPnP discovery in Local Networks ................................................................................................ 27
UPnP Activation ............................................................................................................................... 28
WARRANTY TERMS AND CONDITIONS ................................................................................. 29
Product Registration Card .............................................................................................................. 30
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
- 4 -
Introduction
DEVA Broadcast Ltd. is an international communications and high-technology manufacturing
organization, its corporate headquarters and facility located in Burgas, Bulgaria. The company
serves the broadcast and corporate markets worldwide – from consumers and small businesses to
the largest global organizations. It is dedicated to the research, design, development and provision
of advanced products, systems and services. DEVA launched its own brand back in 1997 and has
nowadays evolved to become known as a market leader and internationally reputed manufacturer
of user-friendly, cost-effective and innovative broadcast products.
Creativity and innovation are deeply woven into DEVA corporate culture. Through successful
engineering, marketing and management our team of dedicated professionals creates future-
oriented solutions to improve customers’ performance. You may rely that all issues communicated
to our crew would be addressed accordingly. We pride ourselves on our pre and post-sales support
and purchase services, which along with the outstanding quality of our radio gear have won us due
respect and the market authority position.
DEVA best-of-breed solutions have become the best sellers for our partners. The strategic
partnerships which have been formed with industry leaders during all these years that we have been
operating on the broadcasting market, have proved us a reliable business partner and a valuable
asset, as our dealers worldwide would confirm. In constant pursuit of precision and long-term
satisfaction, DEVA enhances the reputation of our partners and clients alike. Furthermore, we have
already a proven merit as a credible partner provider.
Our portfolio offers complete line of high quality and competitive products for FM and Digital
Radio, Radio Networks, Telecommunication Operators and regulation authorities. For almost
two decades of intensive software and hardware development, we have achieved a unique price-
performance and endurance of our product lines. Our company’s multitude of equipment and
services is in line with the latest technologies and key trends. The most recognizable characteristics
attributed to DEVA products are their clear-cut, streamlined design, easiness of use and cost-
effectiveness: simplicity of forms but multiplicity of functions.
For us there is no stage when we deem that we have reached the most satisfactory level in our
work. Our engineers are in constant pursuit of new ideas and technologies to be captured in DEVA
solutions. Simultaneously, a strict control is being exercised at each step of any new development.
Experience and hard work are our fundament but the continuous improving process is what we
never leave aside. DEVA participates on a regular basis in all landmark broadcasting events, not
only to promote its products, but to exchange valuable know-how and experience. We are also
engaged in international large-scale projects involving radio and audio solutions which makes us
even more competitive on the global market.
All DEVA products are developed and produced in accordance with the latest ISO 9001 quality
control standards.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
- 5 -
Typographic conventions
This manual uses the following typographic conventions:
Style
Used for
NOTE
Important notes and recommendations
Example
Used when example text is cited
“Menu” on page XX.
References
[OK]
Interface Interactive buttons.
Settings
Menu paths are represented as follows: Settings> General> Backup
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
- 6 -
General Information
DB90-RX IP Audio Decoder is an integrated decoder for IP transmitted digital audio signal. It is
a device designed to support HE-AAC and MPEG-1 Layer 3 compressed audio streams and PCM
uncompressed stream for audio reception without quality loss.
Decoding takes place in real time by a powerful DSP processor and the output signal is both in
digital and analog form. No matter how sophisticated, DB90-RX is located in a small and compact
housing. All this allows you to quickly and painlessly integrate existing audio systems to the
Internet.
Developed with the thought of easiness of use, DB90-RX can be managed through a standard
Web browser, PC, PDA or other device.
APPLICATION
• Audio reception over IP-based networks.
• Point-to-Point Audio Transfer (DB90-TX IP Audio Encoder is required at the opposite site).
• Suitable for professional and consumer use.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
- 7 -
PRODUCT FEATURES
• High Quality HE-AAC (v.1 and v.2), MPEG-1 and MPEG-3 Decoding;
• 32 kHz, 44.1 and 48 kHz sample rates support;
• Support of all standard bitrates and VBR as well;
• 6 LEDs and Phones output for quick diagnostics;
• IP address pronunciation at startup (through the headphones);
• Easy setup via a standard web browser;
• UPnP for easy discovery in Local Networks;
• Status monitoring via SNMP
• Source switch notification via SNMP
• Shoutcast / Icecast compatible TCP/IP client;
• Automatically switching to another server in the event of a connection error or loss;
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
- 8 -
TECHNICAL SPECIFICATIONS
Audio decoder
Decoder
HE-AAC (v.1 and v.2), MPEG-1 Layer 3 or raw PCM
Sample rates
32, 44.1 and 48 kHz
Bit Rates
All standard bitrates, including VBR
Analog audio output
Connector
2 x RCA, stereo
Type
Unbalanced
Level
+9dBu @ 0dBFs
Sample rate
Same as the source stream
Dynamic range
101 dB
Digital audio output
Connector
RCA
Type
S/PDIF (IEC 60958)
Sample rate
48 kHz
Resampling
Thru build-in sample rate converter
Stream client
Type
Shoutcast/Icecast compatible TCP/IP client
Codec Support
Codec Support AAC, MP3, PCM
Servers
Up to 3 with auto-switch on failure
RTP Receiver
Type
Unicast RTP/UDP compatible receiver
Codec
AAC, MP3
Count
1
Phones audio output
Connector
1/8” (3.5mm) jack, stereo
Type
Headphones
User interface
Indicators
6 LEDs on front panel
Web interface
Full control and status information
Network
Connector
RJ-45
Type
Ethernet
Device discovery
UPnP support
Operating conditions
Temperature
10ºC - 45ºC
Humidity
< 75%, non-condensing
Power requirements
Connector
Power Jack 1/4” (6,3 mm)
Power supply
12V DC, 1A
Size and weight
Dimension (W x H x D)
4,17” x 1,3” x 5” (106 x 33 x 128 mm)
Weight
0,44 lbs (0,2 kg)
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
- 9 -
BLOCK DIAGRAM
A simplified block diagram of DB90-RX IP Audio Decoder is shown below
D/A
ANALOG
AUDIO
L
R
WEB SERVER
STREAM CLIENT
MP3 DECODER
HE-AAC v2 DECODER
POWER
LAN
DIGITAL
AUDIO
S/PDIF
TX
PHONES
DSP
Because of the all-digital, minimalist-discrete-component nature of device circuitry, we have not
provided schematic diagrams of the DB90-RX in this Manual. As they say on the back of TV sets:
NO USER-SERVICEABLE COMPONENTS INSIDE.
REFER ALL SERVICING TO
QUALIFIED TECHNICAL PERSONNEL.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
- 10 -
Safety Precautions
IMPORTANT: Carefully read this paragraph as it contains important instructions concerning
operator safety and directions regarding the installation, operation and maintenance of the
equipment. Failure to observe the safety instructions and information given in this manual
constitutes an infringement of the safety rules and design specifications provided for this piece
of equipment.DEVA Broadcast Ltd. declines all responsibility if any one of the safety rules given
herein is not observed. DEVA Broadcast Ltd. declines all responsibility if the end-user resells the
product. The equipment is to be used by people capable of operating it in a trouble-free manner
and it is assumed that they are aware of the following safety rules.
◊ Keep this manual with the utmost care and close at hand so that it can be consulted whenever
needed
◊ After unpacking the equipment, check it for condition.
◊ Avoid banging the equipment.
◊ The packing material (plastic bags, polystyrene, nails, etc.) must never be left within the reach
of the children, as these items are potential sources of danger.
◊ Do not use the equipment in places where the temperature is not within the recommended
range, as specified by the manufacturer.
◊ Before connecting the equipment, make sure the nameplate specifications correspond to the
mains electricity supply (the nameplate is located on the equipment enclosure).
◊ Do not remove the sticker from the equipment as it contains important specifications and the
relevant serial number.
◊ To join the equipment to the mains supply, use the power cord purchased with the equipment.
◊ The equipment must be used only for the purpose it was designed for.
◊ Abuse or misuse of the equipment is extremely dangerous for people, pets and property. The
manufacturer declines all responsibility for damage and injury resulting from improper use and
mishandling.
◊ Certain basic safety rules must be observed when using electrical equipment, in particular:
- Never touch the equipment with wet and/or damp hands or other parts of the body.
- Keep the equipment away from drops of water or sprinkling systems.
- Never use the equipment near high heat sources or explosive material.
- Do not introduce any extraneous matter into the equipment.
- Do not allow children or untrained people to use the equipment.
◊ Before cleaning or servicing the equipment outside, disconnect it from the supply and wait at
least 2 seconds before working on it, as recommended by current safety regulations.
◊ In the event of faults and/or improper operation, turn off the equipment, shut off the electrical
power and call your dealer.
◊ Do not attempt to make repairs and/or adjustments when covers/guards or circuit boards are to
be removed.
◊ Call your dealer for any repairs and be certain original spare parts are used. Failure to observe
this rule may adversely affect the safety level of your equipment.
◊ The equipment is to be connected to the mains supply and provided with adequate and efficient
earth conductors.
◊ When installing, leave a clearance of at least 1 cm around the equipment to allow air to pass
freely.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
- 11 -
Panel Indicators and Appointments
FRONT VIEW
PHONES
LAN
PWR
BUSY
L
R
1
2
3
4
5
6
7
8
1 - Phones Output. The following audio signals are reproduced through the headphones:
Voice Announcement of DB90-RX IP Audio Decoder IP address upon startup;
Audio signal identical to that of the outputs audio;
2 - Left Channel Level LED Indicator. This LED can be in one of the following states:
Off - the channel level is within norms;
Blinking – indication of low signal level;
Constantly lit – indication of high signal level;
3 - Right Channel Level LED Indicator. This LED can in one of the following states:
Off - the channel level is within norms;
Blinking – indication of low signal level;
Constantly lit – indication of high signal level;
4 - Status LED Indicator. Blinking frequency of this LED is indication of DB90-RX state:
Fast blinking – in process of connection;
Approximately once per second – data buffering;
Approximately once per 2 seconds – DB90-RX is connected and operating normally;
5 - Power LED Indicator.
6 - LAN Port / Internet Input – standard RJ-45 port;
7 - Network Activity LED Indicator (RJ-45 built-in);
8 - Network Availability LED indicator (RJ-45 built-in);
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
- 12 -
REAR VIEW
TCP/IP MINI AUDIO TOOL
LEFT
RIGHT
S/PDIF
POWER
12V / 2A
1
2
3
4
5
1 - Left Line Analog Output – standard RCA female jack;
2 - Right Line Analog Output – standard RCA female jack;
3 - Factory Defaults Reset button;
4 - S/PDIF Output – standard RCA female jack;
5 - Power Supply (12V, 1A);
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
- 13 -
Connecting of DB90-RX
ANALOG AUDIO OUTPUTS
Using a cable ending with two standard RCA jacks connect DB90-RX analog signal outputs to
the analog audio inputs of your equipment.
DIGITAL AUDIO OUTPUT
Using a cable ending with a standard RCA jacks connect DB90-RX S/PDIF output to the digital
audio input of your equipment.
LAN PORT
For normal operation it is necessary the device to be connected to a local network or Internet
by cable with RJ-45 connector.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
- 14 -
Operation
DB90-RX is controlled through the built-in web server and a standard web browser can be used
to monitor its status or make some adjustments. To connect to the device you need to know its IP
address and follow the next steps:
• Open a WEB Browser.
• Enter the device IP address in the browser’s address field.
• Press .
If you do not know the device IP address you can hear it through the headphones when you turn
on the device. The other option to find out the IP address is using UPnP discovery in local networks
(see “UPnP discovery in Local Networks” on page 27).
The web interface consists of the following pages:
• Status
• Configuration
- Network
- IP Audio
• Factory Defaults
• Reboot
• Firmware Update
At the top of each page is located the Navigational Menu and underneath, on the left side is the
section with relevant information and adjustment fields. There is a kind of help section on the right
side, containing brief information about each of the fields on the left.
Hover with your mouse over any of the left side fields to bring out a field’s description next to
the mouse pointer.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
- 15 -
The picture below is illustrating STATUS page opened:
NOTE: As shown on the picture below a Username and Password may be requested if the
Access Control is turned on and a page other then STATUS is selected (see “Web Server Settings”
on page 19). Defaults values are user and pass.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
- 16 -
STATUS
On the picture below is shown the page with current device status:
This page contains information regarding current status of DB90-RX as follows:
• Audio Status;
• Network Status;
• Connection Status;
NOTE: Level of the Audio signal is dynamically updated.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
- 17 -
Under Network Status are shown MAC address and current IP address, Network mask and
Gateway and the method in which they have been assigned: Static Allocation or allocated by
DHCP server. Shown are also the primary and secondary DNS servers.
Connection Status is the place showing which one of the three available URLs is currently used,
device status (connected or disconnected), connection time, stream parameters and name.
Please note that if a compressed stream is used, Sample rate and Bitrate will be taken from the
stream. If the stream is in uncompressed format (PCM) then what is displayed for Sample rate and
Bitrate is what is set in the Configuration page.
In the upper right corner is located LIVE DATA icon. Clicking on the icon will toggle live data
ON and OFF as follows:
- live data is ON
- live data is OFF.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
- 18 -
DB90-RX CONFIGURATION
Applying New Settings
In order new settings to take effect, it is necessary to press the SAVE button. Please keep in
mind that some of the new settings can reset the device.
Network Settings
• DHCP – As DHCP Client is used to automatically obtain the Network Settings it can be
enabled or disabled. Default value is ON.
• IP Address – A field where static IP address is to be entered in case that DHCP client is not
used. Example: 192.168.0.2.
• Netmask – A field where static subnet mask is to be entered. This parameter is not used if the
DHCP Client is enabled. Example for Netmask is: 255.255.255.0.
• Gateway – A field where static gateway is to be entered. This parameter is not used if the
DHCP Client is enabled. Example for gateway is: 192.168.0.1.
• DNS 1 – A field where Static primary DNS server is to be entered. It is not used if DHCP
Client is enabled. Example: 192.168.0.1
• DNS 2 – A field where Static secondary DNS server to be entered. It is not used if DHCP
client is enabled. Example: 192.168.0.1
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
- 19 -
Web Server Settings
• Port – This is the TCP port of the WEB Server. Default value is 80.
• Username – User name for the WEB Server. Default value is user.
• Password – Password for the WEB Server. Default value is pass.
NOTE: Username and Password are used in order to restrict access to all configuration pages.
You can define Username only, Password only or both of them. If both Username and Password
are left blank, NO security is used.
SNMP Settings
SNMP MIB File: Press the Download button to download DB90-RX SNMP MIB file.
NOTE: The MIB file may change from one firmware revision to the other. Downloading this
file from the device ensures that you have the proper MIB file.
Specify Agent ID, Agent Port, Read/Write Communities, Manager IP and Manager Port.
NOTE: Agent ID is used to identify the device among others when a SNMP notification is send.
Agent - enables/disables SNMP Agent.
Other Settings
• Name – Name of the device. This name is used to identify the device in local network and is
used as title on all web pages. Up to 63 alpha-numeric characters can be entered.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
- 20 -
IP Audio Settings
• URL – URL of the stream server. Up to 3 URLs can be defined. Up to 63 characters can be
entered.
• Decoder + Sample rate – Select decoder and sample rate. For PCM (uncompressed) sample
rate can be 32, 44.1 or 48 kHz. For HE-AAC and MPEG1 sample rate is determined
automatically from the stream. Default value is HE-AAC / auto.
• Channels – Number of channels in PCM stream: 1 or 2. NOTE: This is not used for encoded
stream.
• Prebuffer – Minimum size of data in buffer before playing starts. Must be in the
range10240-65535. Default value is 32768.
• Buffering timeout – Seconds to wait for buffer to fill up. If the timeout is reached the device
will skip to next server. Default value is 30s.
• Gain Adjust - Audio gain adjust from -10 to 10 dB. Default value is 0dB.
NOTE: “Gain Adjust” is digital. If the sum of Signal Level and Gain is greater than 0dBFs the
signal will be distorted.
Analog Audio Output Settings
• Analog Level – Analog output volume from 0 to 100%. Default value is 100%.
NOTE: In order to ensure normal operation when PCM is used, it is necessary to select the
same sample rate at both encoding and decoding side.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
- 21 -
Audio Source Switching
DB90-RX has one main (URL1) and two alternative (URL2, URL3) Stream Audio Sources.
Switching between streams is immediate and is performed automatically when connection with
the current stream is lost.
NOTE: When current Stream is URL2 or URL3 and connection to URL1 is restored there will
be instantaneous switch back to URL1.
SOURCE
PRIORITY
TIME
URL 1
URL 2
URL 3
Audio Output
URL 1
Connection Loss
NO URL 3 Stream
Connection Restored
URL 2
URL 1
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
- 22 -
FACTORY DEFAULTS SETTINGS
On the above picture is shown the Factory Defaults page. Restoring DB90-RX to its Factory
Defaults can be done by following the next steps:
• Press the “Restore” button.
• A new window as the one shown below will appear:
• Confirm that you want to restore factory defaults.
• Wait for the process to complete.
NOTE: All the settings will be restored to their factory defaults except the Network Settings,
which will remain the same.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
- 23 -
On completion of the process DB90-RX settings will have the following values:
Stream Default Settings
• URL 1, URL 2 and URL 3 – blank fields
• Decoder + Sample rate: MPEG1 / auto (MP3)
• Channels: 2
• Volume: 100 %
• Prebuffer: 32768
• Buffering timeout 30 s
• Gain Adjustment: 0dB
Output Levels:
• Analog Output: +6 dBu
Network Default Settings
All General Network Settings will remain unchanged.
WEB Server Default Settings
All WEB Server Settings will remain unchanged.
SNMP Default Settings
• Agent : Disabled
• Agent Port: 161
• Community: DEVA90
• Manager IP: 0.0.0.0
• Manager Port: 162
• Agent ID: 0
Other Default Settings
•
Name: DB90-RX
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
- 24 -
HARDWARE RESET
This process will fully restore DB90-RX to its Factory Defaults, including the Network settings.
Hardware Reset can be done by following the next steps:
•
Disconnect the power supply cable from the unit.
•
Locate the RESET button on Rear panel.
•
Press and hold the RESET button.
•
Connect the power supply cable to the unit.
•
Keep the RESET button hold until the POWER led starts blinking.
•
Release the RESET button.
•
Wait for DB90-RX to reboot with the factory default settings.
Upon completion of the process DB90-RX settings will have the following values:
Network Default Settings
• DHCP: enabled
WEB Server Default Settings
• Port: 80
• Username: user
• Password: pass
All other settings will have the factory default values described in chapter “Factory Defaults
Settings”.
NOTE: After the process completes the DHCP Client is enabled. The DB90-RX will obtain IP
Address from DHCP server shortly.
ATTENTION: Please note that the WEB Server’s Port, Username and Password will be
changed, so it is possible the page not to be loaded after restoring factory defaults. You may be
asked to re-enter the encoder’s address and/or username and password.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
- 25 -
REBOOTING
On the above picture is shown the Reboot page. Rebooting of DB90-RX can be done by
following the next steps:
• Press the “Reboot” button.
• The following dialog warning window will appear:
• Confirm that you want to reboot the device.
• Wait for the process to complete.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
- 26 -
FIRMWARE UPDATE
On the above picture is shown the Firmware Update page. To update the device firmware,
please follow the next steps:
• Select the new firmware file.
• Press the “Upload” button.
• The following dialog window will appear:
• Wait for the process to complete.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
- 27 -
UPnP discovery in Local Networks
DB90-RX implements UPnP which lets you easily find it in your local network. For this purpose
your system should have UPnP enabled (see “UPnP Activation” on page 28). To discover the device
follow the next steps:
•
Connect the device to the local network.
•
Open “My Network Places” on your computer.
•
Find the decoder’s icon.
•
Double click it to open the DB90-RX web interface.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
- 28 -
UPnP Activation
NOTE: The following explanations apply to Windows XP SP2 or SP3! If you use another
operating system, please contact your system administrator.
Open “My Network Places”. If you have the caption displayed in the picture below, click on it.
Then click “Yes” and wait for the process to complete. Now you should see the device. If you still
have troubles finding the device, please see
http://support.microsoft.com/kb/941206 or contact your system administrator.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
- 29 -
WARRANTY TERMS AND CONDITIONS
I. TERMS OF SALE: DEVA Broadcast Ltd. products are sold with an understanding of “full
satisfaction”; that is, full credit or refund will be issued for products sold as new if returned to the
point of purchase within 30 days following their receipt, provided that they are returned complete
and in an “as received” condition.
II. CONDITIONS OF WARRANTY: The following terms apply unless amended in writing
by DEVA Broadcast Ltd.
A. The Warranty Registration Card supplied with this product must be completed and returned
to DEVA Broadcast Ltd. within 10 days of delivery.
B. This Warranty applies only to products sold “as new.” It is extended only to the original end-
user and may not be transferred or assigned without prior written approval by DEVA Broadcast Ltd.
C. This Warranty does not apply to damage caused by improper mains settings and/or power
supply.
D. This Warranty does not apply to damage caused by misuse, abuse, accident or neglect. This
Warranty is voided by unauthorized attempts at repair or modification, or if the serial identification
label has been removed or altered.
III. TERMS OF WARRANTY: DEVA Broadcast Ltd. products are warranted to be free from
defects in materials and workmanship.
A. Any discrepancies noted within TWO YEARS of the date of delivery will be repaired
free of charge, or the equipment will be replaced with a new or remanufactured product at
DEVA Broadcast Ltd. option.
B. Parts and labor for factory repair required after the two-year Warranty period will be billed
at prevailing prices and rates.
IV. RETURNING GOODS FOR FACTORY REPAIR:
A. Equipment will not be accepted for Warranty or other repair without a Return Authorization
(RA) number issued by DEVA Broadcast Ltd. prior to its return. An RA number may be obtained
by calling the factory. The number should be prominently marked on the outside of the shipping
carton.
B. Equipment must be shipped prepaid to DEVA Broadcast Ltd.. Shipping charges will be
reimbursed for valid Warranty claims. Damage sustained as a result of improper packing for return
to the factory is not covered under terms of the Warranty and may occasion additional charges.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
- 30 -
PRODUCT REGISTRATION CARD
• All fields are required, or warranty registration is invalid and void
Your Company Name
Contact
Address Line 1
Address Line 2
City
State/Province
ZIP/Postal Code
Country
E-mail
Phone
Fax
Which DEVA Broadcast Ltd. product did you purchase?
Product Serial #
Purchase date / / Installation date / /
Your signature*
*Signing this warranty registration form you are stating that all the information provided to DEVA Broadcast Ltd. are truth and correct.
DEVA Broadcast Ltd. declines any responsibility for the provided information that could result in an immediate loss of warranty for
the above specified product(s).
Privacy statement: DEVA Broadcast Ltd. will not share the personal information you provide on this card with any other parties.