Fluke 52120A Operation & User’s Manual

File Specifications

Brand: Fluke
Category: Amplifier
Model: 52120A (Operation & User’s Manual), prh1DayHvE9Ks
File Info: Adobe Acrobat PDF (DjVu)
File Size:
Pages: 98 pages

Download PDF

Download Fluke 52120A Manual (98 pages)

Read Online:

Read the Fluke 52120A Operation & User’s Manual online using the built-in PDF viewer. This document explains how to operate the device, adjust settings and perform regular maintenance.

Key Pages of Document

Introduction and Specifications

Front-Panel Features 1 1-11 Table 1-4. Front-Panel Features (cont.) Item Description  Mains Power Switch The power switch turns the power on and off. The switch is a latching push-push type. When the switch is latched in, power is on. Note The front panel power switch operates electronically and is not an isolation switch. The main power ON/OFF isolation switch is on the rear panel.  Chassis ground connection  Input Terminals Used to input voltage or current to the Product.  A V Sets the INPUT to receive voltage or current.  INPUT OVER RANGE Indic ...

All test equipment must be energized a sufficient time so they operate at

their full specification. Refer to the applicable user documentation. 1. Set the calibrator to 0 volts dc in standby mode. 2. Open the guard to ground link on the calibrator. 3. Push V on the Product to set the input to volts. 4. Push K on the Product to set the output terminals. 5. Push B on the Product to set the range to 2 A. 6. Set the DMM to the 2 volt range. 7. Configure the DMM to 2wV, Resolution to 6 digits, Filter off, and Fast off. 8. Set DMM guard to local. 9. Set the DMM to ...

Table 5-5. 120 Amp Range Verification Points (cont.)

5720A Output 8508A ACV filter 8508A Input A40B Measured Error (%) Product Specification (99 %) Measurement uncertainty (99 %) TUR 0.8 V, 3 kHz 100 Rear 100 A - Reference level 1 V, 3 kHz 100 Front 100 A ±0.6000 % ±0.0117 % >25:1 0.8 V, 6 kHz 100 Rear 100 A - Reference level 1 V, 6 kHz 100 Front 100 A ±1.5400 % ±0.0117 % >25:1 0.8 V, 10 kHz 100 Rear 100 A - Reference level 1 V, 10 kHz 100 Front 100 A ±4.9000 % ±0.0117 % >25:1 Current Input Burden Resistor Verification 1. Push S on the Product and 5720A. 2 ...

INPUT OVER RANGE

L COMP POWER 10V PK MAX OPTION POWER OUTPUT (12V DC) 52120A TRANSCONDUCTANCE AMPLIFIER HI LO HI LO HI LO Current Shunt (A40B) Voltage Source (5720A) 52120A DMM (8508A) 8508A (Rear) LOW CURRENT OUTPUT 850V PK MAX 30A PK 7V PK MAX HI LO ...

Coverage factor k=2.00 (95 % confidence level)

Current Accuracy Frequency 1-year accuracy, tcal [1] ±5 °C ±(% of output + % of range 6105B 6100B % of output % of range % of output % of range DC 0.012 0.008 0.017 0.019 10 Hz to 850 Hz 0.009 0.002 0.021 0.002 850 Hz to 6 kHz 0.040 0.004 0.040 0.004 6 kHz to 10 kHz See Operated Stand Alone current accuracy table. [1] tcal is the temperature at which calibration adjustment took place. Notes: Maximum inductance for stability LCOMP OFF is 100 μH. Maximum inductance for stability LCOMP ON is 400 μH for 2 A and 20 A range ...

How to Setup Multiple Amplifiers 2

2-13 Fluke 52120A #1 Fluke 52120A #2 gpp017.eps Figure 2-5. Master to Slave Connections The first Product is the master and the second the slave. Connect the input signal to the master Product front-panel terminals. The second Product senses the input signal through the control cable. The two Products are controlled through the front panel of the master Product. All the keys but the STBY key are turned off on the slave Product. Connect the outputs of amplifier 1 and 2 to the load as shown in Figure 2-6. ...

Calibration ............................................................................................ 5-1

Introduction ........................................................................................................ 5-3 Calibration Correction Factors ...................................................................... 5-3 Equipment Required ...................................................................................... 5-3 Initial Setup and Input Zero Adjustments ...................................................... 5-3 Calibration Verificat ...

Table 5-3. 2 Amp Range Verification (cont.)

5720A Output 8508A ACV filter 8508A Input A40B Measured Error (%) Product Specification (99 %) Measurement uncertainty (99 %) TUR -2 Vdc - Front 2 A ±0.0150 % ±0.0030 % 5.0:1 0.56 V, 10 Hz 10 Rear 2 A - Reference level 1.4 V, 10 Hz 10 Front 2 A ±0.1150 % ±0.0051 % 23:1 0.8 V, 57 Hz 40 Rear 2 A - Reference level 2 V, 57 Hz 40 Front 2 A ±0.0850 % ±0.0037 % 23:1 0.8 V, 300 Hz 100 Rear 2 A - Reference level 2 V, 300 Hz 100 Front 2 A ±0.1000 % ±0.0037 % >25:1 0.8 V, 1 kHz 100 Rear 2 A - Reference level 2 V, 1 kHz 100 ...

Fluke 52120A user guide recommended for: 5205A, 2HP-D, GM-X822 X1R/UC, ATM7000USB, 203A.

⚠️ Download Safety

The Amplifier Operation & user’s manual (98 pages) is completely safe to download (last scan date: 02/01/2026).

Related PDF Instructions for Fluke 52120A:

Amplifier Equipment: Frequently Requested

Have some Questions about Fluke 52120A Device?

Get valuable and actionable advices from other Fluke 52120A device users. Describe your problem or question, regarding the using of 52120A, in as much detail as possible, and other users will be able to answer you.