Thank you for purchasing COMMAX products.

Please carefully read this User’s Guide (in particular, precautions for safety) before using a product and follow instructions to use a product exactly. The company is not responsible for any safety accidents caused by abnormal operation of the product.

Keep out of direct sunlight and heat radiation sources.

Shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases, shall be placed on the products. When cleaning, do not use liquid solvent or wet cloth. Wipe with soft cloth. Never disassemble or modify this device in any way. (Identery is not liable for problems caused by unauthorized modification or attempted repair) Cautions Before using this device, read and follow all instructions for safety. COMMAX Access Control Solutions

Do not install this device near by TV, monitor or magnetic interference.

If the product fails to operate normally, contact the authorized dealer or service senter. Cautions Before using this device, read and follow all instructions for safety. COMMAX Access Control Solutions

Light on for system status.

Fingerprint sensor Used to register or identity the user. Function Key Speaker Color TFT LCD Displays time, device status, user list and UI for operation. Key button for operation. Connector For cable connection. Parts and Their Functions COMMAX Access Control Solutions

Front View Bracket

Bracket Side View Dimensions This system comes with the following comeponents. COMMAX Access Control Solutions

You have to register fingerprint in proper way to enhance

recognition rate. Recommended to use finger which has no damage. Recommended to register more than two fingerprint in case. Proper way Improper way. Fingerprint Registration Place the finger on the sensor as seen in below in the proper way. Place the entire area of your finger firmly to the sensor. COMMAX Access Control Solutions

T65 supports various type of access mode : Combination of Fingerprint, Card and ID(PIN)

Verification mode can be setup in verification mode (Settings>Basic>Verification Mode) Vertfication Mode COMMAX Access Control Solutions

Function Key is usually used for Time & Attendance.

The admin is able to setup a certain definition to a function key in the program (F1 = Sing in) The admin is able to find out the users attendance records. ID Authentication Scheme F1~F4 + 0~9 CARD Authentication Scheme F1~F4 + 0~9 1. Press Function Key (F1~F4) only or press numbers after Function Key . 2. Present the card to enter. FD Authentication Scheme F1~F4 + Fingerprint 1. Press Function Key (F1~F4) only or Press numbers after Function Key . 2. Place Finger Print to enter. 1. Press Function Key (F1~F4) only or Press numbers after Function Key . 2. Input ID used to enter. Functions Key COMMAX Access Control Solutions

1.Enroll 2.Delete 3.Set Temp ID

1.Basic 2.Advanced 3.AC Setting 4.Communication 5.Schedule 6.Log Setting 1.Download General Log 2.Download All General Log 3.Download Management Log 4.Download All Management Log 5.Download User Info 6.Upload User Info 7.Upgrade Firmware 1.Memory 2.Device Info 3.Advanced 1.Test All 2.Test Memory 3.Test LCD 4.Test Sound (AUTO) 5.Test Sound (MANUAL) 6.Test Sensor 7.Test Keyboard 8.Test RTC 9.Test Case Status 10.Test Card Reader T65 System Directory on Key COMMAX Access Control Solutions

1.Basic 2.Advanced 3.AC Setting 4.Communication 5.Schedule 6.Log Setting

Basic 1.Time 2.Date 3.Date Format 4.Language 5.Use Busytone detection 6. Set Phone Numbers Advanced 1.Vertification Mode 2.ID Mask 3.Use Tamer Alram 4.Use Touch Sensor 5.Celibrate Senseor 6.Restore Factory Settings 7.Clear General Log 8.Clear Management Log 9.Clear Enroll Date AC Settings 1.Define Timezone 2.User Timezone 3.Lock Type 4.Lock Door Release Time 5.Door Open Warning 6.Re-access Count 7.Re-access Limit Time 8.Wiegand Format 9.Anti-Passback T65 System Tree Structure COMMAX Access Control Solutions

1.Basic 2.Advanced 3.AC Setting 4.Communication 5.Schedule 6.Log Setting

Communication 1.Device ID 2.Baudrate 3.TCP/IP Settings -DHCP -IP Antipass -Subnet Mask -Default Gateway -Port -Mac Address 4.Communication Password Schedule 1.Set Tmode 2.Ring Settings 3.Auto Door 4.Auto Funckey 5.None-Relat Funckey 6.Day Light 7.Holiday 8.Funckey Alarm 9.Idle Settings Log Setting 1.Management Log Warning 2.General Log Warning T65 System Tree Structure COMMAX Access Control Solutions

These displays are primary screens.

Verification Mode Date and Time User Menu User Enroll Menu Settings Menu COMMAX Access Control Solutions Displays

To previous menu

Home Screen Select the Menu F1 F2 * # F4 F1 F2 Menu Navigation Buttons COMMAX Access Control Solutions

Default condition and admin is not registered.

> 1 2 3 4 > > Menu Screen F1 F2 * # 1.Press Button. 2.After “1 2 3 4”, Press Button 3.Succeed to access system menu 4.Move between menus using or button * # Access To The System Menu 1 COMMAX Access Control Solutions

Admin is registered already.

F1 F2 * # * > Admin ID > > Verify Fingerprint or CD > Main menu 1. Press Button. 2. Press Registered admin ID and 3. Verify fingerprint or CD of the above ID 4. Succeed to access system menu. 5. Move between menus using or button. Press Button at the bottom left corner to return home Screen. * * Access To The System Menu 2 Only when admin is registered. Refer to “Admin Registration part” for admin registration. When admin ID is incorrect, access to the system menu is denied. When admin ID is not registered anyone can be access to system menu. So it is highly recommended to register admin More than one. Unless stated otherwise instructions in this manual stars from system menu. COMMAX Access Control Solutions

When ADMIN is not registered

F1 * # * > 1234 > > User > Enroll 1. Press button 2. After “ 1 2 3 4 ” , press button (Access to the system menu) 3. Select “ User” and press button 4. Select “ Enroll” and press button 5. Input password(USER ID) and set up the privilege; User or Admin. ( After User ID, press and set the privilege using the and button ) 6. Register fingerprints and/or card ( Refer to p. 16, Menu Navigation Buttons ) # # # # F1 Register COMMAX Access Control Solutions

When ADMIN is not registered

F1 * * > Admin ID > Admin verification > User . Enroll # # # F1 1. Press button 2. After “ Admin ID ” , press button 3. Verify Fingerprint or CD of the above Admin ID (Access to the system menu) 4. Select “ Enroll ” and press button 5. Input password(USER ID) and set up the privilege ; User or Admin. ( After User ID, press and set the privilege using the and button ) 6. Register fingerprints and/or card ( Refer to p. 16, Menu Navigation Buttons ) COMMAX Access Control Solutions Register Default admin ID is 1234. When the new admin is registered, 1234 does not work anymore. Tip : In case of the absence of the admin, multiple admin is recommended.

1. Access to the system menu

5. Scan fingerprint 3tiems for one registration 10. Complete fingerprint registration press button an back to home screen) 12. Select Card 15. Complete registration COMMAX Access Control Solutions User Registration If doesn’t need 2nd fingerprint or CARD, it is possible to skip this process.

1. Access to the system menu

fingerprint and repeat the same process 10. Select 2nd fingerprint 11. Scan 2nd fingerprint three times 12. Complete fingerprint registration button an back to home screen) COMMAX Access Control Solutions Admin Registration If doesn’t need 2nd fingerprint or CARD, it is possible to skip this process.

1. Access to the system menu

(Refer to P. 17 or P. 18 for access to the system menu) 2. Select “User” 3. Select “Delete” 4. Input password (“User ID”) to delete 5. Place fingerprint or Card to delete (If want to delete both fingerprint and card of the ID, select Delete All. 6. Press button after selection 7. “ Yes” and complete the delete COMMAX Access Control Solutions Delete Same as registration process, it is able to delete 1st fingerprint, 2nd fingerprint and card in each. If wish to delete all 3data, select“Delete All” and corresponding ID is deleted.

1. Access to the system menu

(Refer to P. 17 or P. 18 for access to the system menu) 2. Press button 3. Select “ User ” 4. Select “ Set Temp ID” 5. Input Temp ID ( upto 8 digits) and press 6. Input access admission times with this temp ID and press (Min. 1, Max. 9) 7. Compete setup temp ID. * # # COMMAX Access Control Solutions Set Temp ID Temp ID cannot be an Admin and not use fingerprint Admin can determine access times of Temp ID (min. 1 ~ max. 9) Access times are expired, Admin can revert it. emp ID leaves log data Pre-registered ID is not used as a temp ID.

1.Basic 2.Advanced 3.AC Setting 4.Communication 5.Schedule 6.Log Setting

Basic 1.Time 2.Date 3.Date Format 4.Language 5.Use Busytone detection 6. Set Phone Numbers Advanced 1.Vertification Mode 2.ID Mask 3.Use Tamer Alram 4.Use Touch Sensor 5.Celibrate Senseor 6.Restore Factory Settings 7.Clear General Log 8.Clear Management Log 9.Clear Enroll Date AC Settings 1.Define Timezone 2.User Timezone 3.Lock Type 4.Lock Door Release Time 5.Door Open Warning 6.Re-access Count 7.Re-access Limit Time 8.Wiegand Format 9.Anti-Passback COMMAX Access Control Solutions T65

1.Basic 2.Advanced 3.AC Setting 4.Communication 5.Schedule 6.Log Setting

Communication 1.Device ID 2.Baudrate 3.TCP/IP Settings -DHCP -IP Antipass -Subnet Mask -Default Gateway -Port -Mac Address 4.Communication Password Schedule 1.Set Tmode 2.Ring Settings 3.Auto Door 4.Auto Funckey 5.None-Relat Funckey 6.Day Light 7.Holiday 8.Funckey Alarm 9.Idle Settings Log Setting 1.Management Log Warning 2.General Log Warning COMMAX Access Control Solutions T65

Set-up the time of the device

Device’s time is applied to the time of the event. So it is important the accurate time. 2. Date Setup the date of the device. 3. Date Format (YYYY-MM-DD) Define date format at home screen 4. Language (Korean/English) Choose the language 5. Use Busy tone detection (No/Yes) If the silent exceeds 1minute, the phone disconnected automatically. Even visitors activate interphone, it returns standby mode and recommend to use. 6. Set Phone Numbers When interphone is connected, the receivers can remote control the door with pass word. Only registered phone numbers are able to control the door and available max. 100 phone numbers. COMMAX Access Control Solutions Basic

1. Verification Mode

Depends on the security level, it is able to adjust the verification mode. 2. ID mask When the user input ID, it hides user ID as xxxxxx and enhance the security. 3. Use Tamer Alarm When it detects tamper, it activate alarm. 4. Use Touch Sensor If touch sensor is on, sensor lights off in normal condition and lights on when the user touch the sensor only. 5. Calibrate Sensor Optical sensor perceive surroundings and optimize the brightness. When use this function, it has to block extraneous light. 6. Restore Factory Settings Reset all settings to the default 7. Clear General Log Delete all general log data 8. Clear Management Log Delete all management log data 9. Clear Enroll Data Delete entire user data including fingerprint, card data and it is unrecoverable COMMAX Access Control Solutions Advanced

1. ANY MODE : Access granted with any form of authorization

2. FINGER : Fingerprint Only – No access with ID or Card 3. CD OR FP 4. ID&FP OR CD 5. ID&FP OR ID&CD 6. ID &FP OR CD & FP 7. OPEN : Always Open (Fail Safe Mode ) 8. CLOSE : Always Closed (Fail-Secure Mode ) – No access with any form of authorization 9. CD : Card Only – No access with ID or Fingerprint 10. ID OR FP : ID or Fingerprint only – No access with Card 11. ID OR CD : ID or Card Only – No access with Fingerprint 12. ID & CD : Both ID and Card required for access – must punch in ID before Card authentication 13. CD & FP : Both Card and Fingerprint required for Access – Card must be authorized before fingerprint authentication 14. ID & FP : Both ID and Fingerprint required for Access – must punch in ID before fingerprint authentication 15. ID & CD & FP : all three formats needed for access Verification Mode COMMAX Access Control Solutions

1.Define Timezone : Able to set-up 256 timezones.

( Refer to Software (Guardian) manual 7.3 Time Zone set-up. 2.User Timezone : Able to allocate 2 time zone for each user. 0 for [ All Time ] and 257 for [ None Time ]. 3.Lock Type : NC or NO Set up door lock type 4.Lock Door Release Time : Default 3sec. Available to adjust between 1 ~ 99sec. 5.Door Open Warning : Once door open, if the door remains open over setting condition, it activates alarm 6.Reaccess Count : No, 0~ 9 Limit reaccess count between no., 0 ~ 9times. 7.Reaccess Limit Time : Limit reaccess time between no. 0 ~ 600minutes. 8.Wiegand Format : 26,34,35,37,64 Designate wiegand output format 26,34,35,37, or 64. Read all wiegand data regardless of wiegand settings 9.Anti-Passback : No / Yes Anti-passback activates through external wiegand input. If there is two controllers for enter and exit, re-enter is allowed only it has exit event data (EX : Public Parking lot, Restricted Area, Membership center ) COMMAX Access Control Solutions AC Settings

1 .Device ID (1 ~ 999)

Device ID ranges between 1 ~ 999. When many devices are connected in one network, each device must have unique address. 2. Baud rate : 115200 bps RS-485 Communication speed 3. TCP/IP Settings - DHCP : No/ Yes Choose DHCP on or off - IP Address : 192.168.1.224 Setup IP Address - Subnet Mask : 255.255.255.0 Setup subnet mask - Default Gateway : 192.168.1.1 Setup default gateway - Port : 5005 Setup TCP Port - MAC Address Displays MAC Address of the device To connect device with software (Guardian) by TCP/IP ( LAN), it must set-up IP Address, Subnet Mask, Gateway, (All the above data is for reference only and an confirm the details in network environment of the PC to connect) 4. Communication Password If the communication password is not correct, it is impossible to communicate with the software COMMAX Access Control Solutions Communications Settings

1. Set Tmode

Setup the door mode and it is converted automatically according to the time and schedule. Refer to Software (Guardian) manual 7-4 controller Special function/ Door mode how to setup the door mode 2. Ring Settings Setup the bell ring schedule. Refer to Software (Guardian) manual 7-4 controller Special function / Bell Time how to setup the bell rings 3. Auto Door Setup the operation time of the automatic door Refer to Software (Guardian) manual 7-4 controller Special function Auto Door how to setup the auto door. 4. Auto Funckey At the designated date and time, the corresponding key is set-up as default. Refer to Software (Guardian) manual 7-4 controller Special function auto F-Key how to setup the auto F-Key. 5. None-Relay Funckey Setup none-relay Funckey and buzzer alarm key. Refer to Software (Guardian) manual 7-4 controller Special function No act F-Key how to setup the No Act F-key. COMMAX Access Control Solutions Schedule

6. Day Light

Setup the daylight. Refer to Software (Guardian) manual 7-4 controller Special function Daylight how to setup Daylight. 7. Holiday Holiday settings must comply with the day of the week Refer to Software (Guardian) manual 7-4 controller Holiday setup 8. Funckey Alarm Once input the alarm key and succeed to identify, it activates buzzer alarm or relay alarm. 9. CD2 Auto Funckey Input card data to the external reader by Wiegand, and succeed to identify, it is used to save the event.. If a controller is connected to a reader, this function gives a function key to the external reader automatically, thus a an automatically setup function key is given to a user who is authorized from an external reader. Events of user entries from the reader are stored. (Ex. For time & attendance) 10. Idle Settings LCD power cut off : 0 ~ 60minutes IDLE mode : 0 ~ 60minutes COMMAX Access Control Solutions Schedule

1. Management Log Warning ( 0 ~ 100)

If the management logo exceeds the setting value, it alarms 2. General Log Warning If the management logo exceeds the setting value, it alarms COMMAX Access Control Solutions Log Settings

Insert USB memory into the slot at the bottom of the device and

up/download the events data and update the firmware i Download General log Download new general events Download All General log Download all general events Download Management log Download new management events Download All Management log Download all management events Download User Info Download user data Upload User info Upload user data Upgrade Firmware Update Firmware COMMAX Access Control Solutions Use Memory

1. User :User numbers which is enrolled in the device

2. Fingerprint : Template numbers which is enrolled in the device 3. ID Card : ID Card numbers which is enrolled in the device 4. General Log : General log ( access event ) numbers 5. Management Log : Management log ( system event ) numbers COMMAX Access Control Solutions Memory

Device info is set from the manufacturer and the user cannot edit this info.

1. Release Date : Displays the device release date 2. Serial Number : Displays the device serial number 3. Manufacturer : Displays the device manufacturer 4. Product Name : Displays the device Name 5. Product Type : Displays the device Type 6. Engine Version : Displays the engine version 7. Firmware Version: Displays the firmware version COMMAX Access Control Solutions Device Info

1.View General Log : Search and view the general access event

2.View Management Log : Search and view the system management event 3.View User info : Search and view the numbers of the fingerprint and card COMMAX Access Control Solutions Advanced

Test All : Test overall status and functions of the device

Test Memory : Test memory and takes 1 ~ 2 minutes . After test, it reboots and displays the result Test LCD : Test LCD Test Sound ( Auto ) : Test Voice announcement automatically. If there is no voice chip, it finishes quickly Test Sound ( Manual ) : Test Voice announcement manually. Test Sensor : Test Finger sensor Test Keyboard : Test keyboard Test RTC : Test RTC Test Case Status : Test the status of the case Test Card Reader : Test the card reading COMMAX Access Control Solutions Self Test