Hardware Reference Guide

This guide describes the hardware features and specifications of the Hitachi Virtual Storage Platform G400 and the Hitachi Virtual Storage Platform G600 storage systems. MK-94HM8022-10 October 2017 Hitachi Virtual Storage Platform G400 and G600 83-04-4x or later

© 2017 Hitachi Vantara Corporation. All rights reserved.

No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, or stored in a database or retrieval system for commercial purposes without the express written permission of Hitachi, Ltd., or Hitachi Vantara Corporation (collectively, “Hitachi”). Licensee may make copies of the Materials provided that any such copy is: (i) created as an essential step in utilization of the Software as licensed and is used in no other manner; or (ii) used for archival purposes. Licensee may not make any other copies of the Materials. "Materials" mean text, data, photographs, graphics, audio, video and documents. Hitachi reserves the right to make changes to this Material at any time without notice and assumes no responsibility for its use. The Materials contain the most current information available at the time of publication. Some of the features described in the Materials might not be currently available. Refer to the most recent product announcement for information about feature and product availability, or contact Hitachi Vantara Corporation at https://support.HitachiVantara.com/ en_us/contact-us.html. Notice: Hitachi products and services can be ordered only under the terms and conditions of the applicable Hitachi agreements. The use of Hitachi products is governed by the terms of your agreements with Hitachi Vantara Corporation. By using this software, you agree that you are responsible for: 1) Acquiring the relevant consents as may be required under local privacy laws or otherwise from authorized employees and other individuals to access relevant data; and 2) Verifying that data continues to be held, retrieved, deleted, or otherwise processed in accordance with relevant laws. Notice on Export Controls. The technical data and technology inherent in this Document may be subject to U.S. export control laws, including the U.S. Export Administration Act and its associated regulations, and may be subject to export or import regulations in other countries. Reader agrees to comply strictly with all such regulations and acknowledges that Reader has the responsibility to obtain licenses to export, re-export, or import the Document and any Compliant Products. EXPORT CONTROLS - Licensee will comply fully with all applicable export laws and regulations of the United States and other countries, and Licensee shall not export, or allow the export or re-export of, the Software, API, or Materials in violation of any such laws or regulations. By downloading or using the Software, API, or Materials, Licensee agrees to the foregoing and represents and warrants that Licensee is not located in, under the control of, or a national or resident of any embargoed or restricted country. Hitachi is a registered trademark of Hitachi, Ltd., in the United States and other countries. AIX, AS/400e, DB2, Domino, DS6000, DS8000, Enterprise Storage Server, eServer, FICON, FlashCopy, IBM, Lotus, MVS, OS/390, PowerPC, RS6000, S/390, System z9, System z10, Tivoli, z/OS, z9, z10, z13, z/VM, and z/VSE are registered trademarks or trademarks of International Business Machines Corporation. Active Directory, ActiveX, Bing, Excel, Hyper-V, Internet Explorer, the Internet Explorer logo, Microsoft, the Microsoft Corporate Logo, MS-DOS, Outlook, PowerPoint, SharePoint, Silverlight, SmartScreen, SQL Server, Visual Basic, Visual C++, Visual Studio, Windows, the Windows logo, Windows Azure, Windows PowerShell, Windows Server, the Windows start button, and Windows Vista are registered trademarks or trademarks of Microsoft Corporation. Microsoft product screen shots are reprinted with permission from Microsoft Corporation. All other trademarks, service marks, and company names in this document or web site are properties of their respective owners.

Intended audience................................................................................................... 8

Safety and environmental notices..............................................................................8 Product version........................................................................................................9 Release notes........................................................................................................ 10 Changes in this revision..........................................................................................10 Document conventions........................................................................................... 10 Conventions for storage capacity values...................................................................11 Accessing product documentation........................................................................... 12 Getting help...........................................................................................................12 Comments.............................................................................................................12 1 Hitachi Virtual Storage Platform G400, G600 hardware overview............. 13 Block configuration.................................................................................................15 Unified configuration.............................................................................................. 15 VSP G400 model.................................................................................................... 15 VSP G600 model.................................................................................................... 17 Features................................................................................................................18 Scalability..............................................................................................................19 Examples of supported VSP G400 configurations.................................................19 Examples of supported VSP G600 configurations.................................................19 Maximum number of mounted drive trays...........................................................20 2 Virtual Storage Platform G400, G600 controller..................................... 23 CBLM controller......................................................................................................24 CBLM with front panel bezel.............................................................................. 24 CBLM front panel LEDs (without bezel)...............................................................25 CBLM rear panel...............................................................................................26 CBLM power supply unit LEDs and connectors.................................................... 28 Host, Network, and Drive Tray Ports and LEDs..........................................................28 Front end module descriptions...........................................................................28 10-Gbps iSCSI board LEDs and connectors (optical).......................................29 3 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

10-Gbps iSCSI board LEDs and connectors (copper)...................................... 29

8-Gbps, 16-Gbps, or 32-Gbps Fibre Channel (4-port) board LEDs and connectors ..................................................................................................................30 16-Gbps Fibre Channel (2-port) board LEDs and connectors...........................32 LAN blade LEDs and connectors.........................................................................33 Back end module LEDs and connectors.............................................................. 34 3 Storage system drive trays.................................................................. 37 Small form-factor (SFF) drive tray............................................................................38 SFF with front panel bezel.................................................................................38 SFF front panel without bezel............................................................................ 38 SFF rear panel..................................................................................................39 Large form-factor (LFF) drive tray............................................................................40 LFF with front panel bezel................................................................................. 40 LFF front panel without bezel.............................................................................41 LFF rear panel.................................................................................................. 42 Flash module drive (FMD) tray................................................................................ 43 FMD with front panel bezel................................................................................43 FMD front panel without bezel........................................................................... 44 FMD rear panel.................................................................................................45 Dense intermix drive tray........................................................................................46 Dense intermix drive tray with front panel bezel..................................................46 Dense intermix drive tray display LEDs............................................................... 47 Dense intermix drive tray rear panel...................................................................48 SFF and LFF AC power supply unit LEDs and connectors........................................... 49 4 Host port expansion chassis..................................................................51 Host port expansion chassis front panel bezel LEDs.................................................. 52 PCIe switchboard................................................................................................... 52 Host port expansion chassis fan.............................................................................. 53 PCIe cable connector..............................................................................................53 Host port expansion chassis power supply............................................................... 55 5 NAS module........................................................................................ 57 NAS Module Ports and LEDs....................................................................................58 6 VSP service processor server................................................................ 59 Service processor description.................................................................................. 60 SVP front panel......................................................................................................60 SVP rear panel.......................................................................................................61 Service processor hardware specifications................................................................62 7 Maintaining the storage system.............................................................63 Storing the storage system..................................................................................... 64 Powering off the storage system............................................................................. 64 Removing cables....................................................................................................64 4 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Mechanical specifications for VSP G400, G600 ......................................67

VSP G400 and VSP G600 mechanical specifications...................................................68 B Electrical specifications for VSP G400, G600...........................................75 Electrical specifications........................................................................................... 76 C Environmental specifications for VSP G400, G600...................................77 Environmental specifications................................................................................... 78 D iSCSI standards and specifications........................................................ 83 iSCSI standards......................................................................................................84 iSCSI specifications................................................................................................ 84 E Replacement parts...............................................................................87 Battery unit........................................................................................................... 88 F Data and power cables.........................................................................89 Fibre Channel cables.............................................................................................. 90 iSCSI cables...........................................................................................................93 Managing data cables.............................................................................................95 AC power cables.................................................................................................... 97 Power cable assemblies.....................................................................................97 AC connections.................................................................................................99 Power cable usage guidelines.......................................................................... 100 Three-phase power considerations for racks......................................................100 Cable management.........................................................................................101 Cable retention...............................................................................................101 G Port address mapping.........................................................................103 Port address mapping...........................................................................................104 H Third-party racks................................................................................105 Third-party rack support for VSP Gx00 models........................................................106 Hitachi Universal V2 Rack rail kits.......................................................................... 106 Hitachi Universal V2 Rack accessories.................................................................... 106 Third-party rack support for DB60 dense intermix drive trays...................................107 I Hitachi Universal V2 Rack power distribution units................................109 Americas single-phase PDU 1P30A-8C13-3C19UL.P.................................................110 Americas single-phase PDU 1P30A-15C13-3C19UL.P............................................... 110 Americas three-phase PDU 3P30A-8C13-3C19UL.P..................................................111 Americas three-phase PDU 3P30A-15C13-3C19UL.P................................................111 Americas three-phase PDU 3P30A-24C13-6C19UL.P................................................112 APAC and EMEA single-phase PDU 1P32A-9C13-3C19CE.P.......................................113 APAC and EMEA single-phase PDU 1P32A-18C13-3C19CE.P.....................................113 5 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

APAC and EMEA three-phase PDU 3P16A-9C13-3C19CE.P........................................114

APAC and EMEA three-phase PDU 3P16A-15C13-3C19CE.P......................................114 APAC and EMEA three-phase PDU 3P32A-24C13-6C19CE.P......................................115 J Regulatory compliance....................................................................... 117 Index................................................................................................119 6 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

This guide describes the hardware features and specifications of the VSP

Gx00 models. □ Intended audience □ Safety and environmental notices □ Product version □ Release notes □ Changes in this revision □ Document conventions □ Conventions for storage capacity values □ Accessing product documentation □ Getting help □ Comments Preface 7 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

This document is intended for customers inquiring about the features and

specifications of the VSP Gx00 models. Readers of this document should be familiar with the following: • Data processing and RAID storage systems and their basic functions. • The operating system and web browser software on the system hosting the storage management software. Safety and environmental notices Equipment warranty The term of guarantee of normal operation of the storage system and free service is one year from date of purchase. If a failure occurs multiple times, the storage system might shut off to avoid a serious accident. Notice of export controls Export of technical data contained in this document might require an export license from the United States government, the government of Japan. or both. Contact the Hitachi Legal Department for guidance about any export compliance questions. Backup Hitachi cannot guarantee against data loss due to failures. Therefore, back up your data to minimize chances for data loss. Data backup is also critical when hardware components are added or replaced, because performing such hardware procedures restores parameter settings that can affect how data is managed on the storage systems. Disposal This symbol on the product or on its packaging means that your electrical and electronic equipment should be disposed at the end of life separately from your household wastes. There are separate collection systems for recycling in the European Union. For more information, contact the local authority or the dealer where you purchased the product. Recycling A nickel-metal hydride battery is used in the Cache Backup Battery. A nickel-metal hydride battery is a resource that can be recycled. When you want to replace the Cache Backup Battery, call the service personnel. They will dispose of it for you. This nickel-metal hydride battery, which is designated as recycling product by a recycling promotion low, must be recycled. The mark posted on the Cache Backup Battery is a three-arrow mark that indicates a recyclable part. 8 Preface Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

UEFI Development Kit 2010

This product includes UEFI Development Kit 2010 written by the UEFI Open Source Community. For more information, see the UEFI Development Kit website: http://sourceforge.net/apps/mediawiki/tianocore/index.php?title=UDK2010 © 2004, Intel Corporation. All rights reserved. Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution. Neither the name of the Intel Corporation nor the names of its contributors might be used to endorse or promote products derived from this software without specific prior written permission. THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS “AS IS” AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. FDA radiation regulation The array complies with FDA radiation performance standard 21 CFR subchapter J. EMI regulation This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference in which case the user will be required to correct the interference at his own expense. Testing was done with shielded cables. Therefore, in order to comply with the FCC regulations, you must use shielded cables with your installation. The electromagnetic interference (EMI) test was done in the following configuration. This product must not be used in residential areas. This is a class A product. In a domestic environment this product can cause radio interference in which case the user can be required to take adequate measures. Product version This document revision applies to the following product versions: Preface 9 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

VSP G400, G600 firmware 83-04-4x or later

• Hitachi Storage Virtualization Operating System (SVOS) 7.2 or later • Hitachi NAS firmware version 13.1 or later Release notes Read the release notes before installing and using this product. They may contain requirements or restrictions that are not fully described in this document or updates or corrections to this document. Release notes are available on Hitachi Data Systems Support Connect: https:// knowledge.hds.com/Documents. Changes in this revision • Added new single- and three-phase power distribution units and specifications • Added third-party rack information Document conventions This document uses the following typographic conventions: Convention Description Bold • Indicates text in a window, including window titles, menus, menu options, buttons, fields, and labels. Example: Click OK. • Indicates emphasized words in list items. Italic • Indicates a document title or emphasized words in text. • Indicates a variable, which is a placeholder for actual text provided by the user or for output by the system. Example: pairdisplay -g group (For exceptions to this convention for variables, see the entry for angle brackets.) Monospace Indicates text that is displayed on screen or entered by the user. Example: pairdisplay -g oradb < > angle brackets Indicates variables in the following scenarios: • Variables are not clearly separated from the surrounding text or from other variables. Example: Status-.csv • Variables in headings. [ ] square brackets Indicates optional values. Example: [ a | b ] indicates that you can choose a, b, or nothing. 10 Preface Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

{ } braces

Indicates required or expected values. Example: { a | b } indicates that you must choose either a or b. | vertical bar Indicates that you have a choice between two or more options or arguments. Examples: [ a | b ] indicates that you can choose a, b, or nothing. { a | b } indicates that you must choose either a or b. This document uses the following icons to draw attention to information: Icon Label Description Note Calls attention to important or additional information. Tip Provides helpful information, guidelines, or suggestions for performing tasks more effectively. Caution Warns the user of adverse conditions and/or consequences (for example, disruptive operations, data loss, or a system crash). WARNING Warns the user of a hazardous situation which, if not avoided, could result in death or serious injury. Conventions for storage capacity values Physical storage capacity values (for example, disk drive capacity) are calculated based on the following values: Physical capacity unit Value 1 kilobyte (KB) 1,000 (10 3) bytes 1 megabyte (MB) 1,000 KB or 1,0002 bytes 1 gigabyte (GB) 1,000 MB or 1,0003 bytes 1 terabyte (TB) 1,000 GB or 1,0004 bytes 1 petabyte (PB) 1,000 TB or 1,0005 bytes 1 exabyte (EB) 1,000 PB or 1,0006 bytes Logical capacity values (for example, logical device capacity, cache memory capacity) are calculated based on the following values: Logical capacity unit Value 1 block 512 bytes Preface 11 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Logical capacity unit

Value 1 cylinder Mainframe: 870 KB Open-systems: • OPEN-V: 960 KB • Others: 720 KB 1 KB 1,024 (210) bytes 1 MB 1,024 KB or 1,0242 bytes 1 GB 1,024 MB or 1,0243 bytes 1 TB 1,024 GB or 1,0244 bytes 1 PB 1,024 TB or 1,0245 bytes 1 EB 1,024 PB or 1,0246 bytes Accessing product documentation Product user documentation is available on Hitachi Data Systems Support Connect: https://knowledge.hds.com/Documents. Check this site for the most current documentation, including important updates that may have been made after the release of the product. Getting help Hitachi Data Systems Support Connect is the destination for technical support of products and solutions sold by Hitachi Data Systems. To contact technical support, log on to Hitachi Data Systems Support Connect for contact information: https://support.hds.com/en_us/contact-us.html. Hitachi Data Systems Community is a global online community for HDS customers, partners, independent software vendors, employees, and prospects. It is the destination to get answers, discover insights, and make connections. Join the conversation today! Go to community.hds.com, register, and complete your profile. Comments Please send us your comments on this document to [email protected]. Include the document title and number, including the revision level (for example, -07), and refer to specific sections and paragraphs whenever possible. All comments become the property of Hitachi Data Systems Corporation. Thank you! 12 Preface Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Hitachi Virtual Storage Platform G400,

G600 hardware overview Hitachi Virtual Storage Platform G400, G600 are modular, rack-mountable, all-flash arrays that deliver high performance, high reliability, and flash- accelerated scalability. The storage system contain dual controllers, each controller contains its own processor, dual in-line cache memory modules (DIMMs), cache flash memory (CFM), battery, fans and iSCSI and Fibre Channel I/O modules. Each controller also has an Ethernet connection for out-of-band management. If the data path through one controller fails, all data drives remain available to data hosts using a redundant data path through the other controller. The storage system can be equipped with embedded network-attached storage (NAS) modules. The NAS modules provide file access through CIFS and NFS protocols and block access by using iSCSI protocols. All storage system models allow defective drives to be replaced without the interruption of data availability to hosts. A hot spare drive can be configured to replace a failed drive automatically, securing the fault-tolerant integrity of the logical drives. Self-contained, hardware-based RAID logical drives provide maximum performance in compact external enclosures. Essential hardware components are implemented with a redundant configuration so that the storage system can remain operational if a component fails. Adding and replacing components, along with firmware upgrades, can be conducted while the storage system is active. □ Block configuration □ Unified configuration □ VSP G400 model □ VSP G600 model Hitachi Virtual Storage Platform G400, G600 hardware overview 13 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Hitachi Virtual Storage Platform G400, G600 hardware overview

Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

A storage system configured for block-level storage provides the ability to

access and provision raw storage volumes using protocols such as Fibre Channel and iSCSI. A block configuration consists of the following: • Two controllers • One or more drive trays • One 1U service processor server (SVP) Unified configuration A unified configuration includes embedded NAS modules that support file system protocols such as CIFS and NFS and operate across a block-level setup using iSCSI or FC connections. • Two controllers • Two NAS modules for file operations and storage • One or more drive trays for block-level storage • One 1U block service processor server (SVP) VSP G400 model The VSP G400 is a highly reliable storage system that offers high storage capacity with full redundancy to better protect data and manage storage operations. The storage system consists of a 4U enclosure that includes two controllers, two optional NAS modules to support file operations. Drives are supported using drive trays connected to the controllers. The maximum number of drives supported is 384 (480 with dense intermix drive tray). The storage system supports 128 GB of high-speed cache memory. The DIMMs are arranged as 64 GB per controller. Storage system interfaces consist of: • 10-Gbps iSCSI: 28 ports per system (or 32 ports per systems for systems without drives or 12 ports per systems when NAS Modules are installed) • 10-Gbps iSCSI (Copper): 28 ports per system (or 32 ports per systems for systems without drives or 12 ports per systems when NAS Modules are installed) • 8-Gbps Fibre Channel: 56 ports per system (or 64 ports per systems for systems without drives or 24 ports per systems when NAS Modules are installed) Hitachi Virtual Storage Platform G400, G600 hardware overview 15 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

16-Gbps Fibre Channel (2-port): 28 ports per system (or 32 ports per

systems for systems without drives or 12 ports per systems when NAS Modules are installed) • 16-Gbps Fibre Channel (4-port): 56 ports per system (or 64 ports per systems for systems without drives or 24 ports per systems when NAS Modules are installed) • 32-Gbps Fibre Channel (4-port): 56 ports per system (or 64 ports per systems for systems without drives or 24 ports per systems when NAS Modules are installed) Controller Controller chassis Controller model Height CBLM DW800-CBL DW-F800-CTLM 4U (174.3 mm) Controller Model number Description NAS DW-F800-NAS Optional component for file storage configuration. NAS modules only provide file support. Drive tray Drive tray model name Supported drive type Number of drives supported Height SFF drive tray • DW-F800-DBS (power supply, contains BNST) • DW-F800- DBSC 2.5-inch SFF 24 2U (86.2 mm) LFF drive tray • DW-F800-DBL (power supply, contains BNST) • DW-F800- DBLC 3.5-inch LFF 12 2U (86.2 mm) FMD tray • DW-F800-DBF 5.25-inch FMD 12 2U (86.2 mm) Dense intermix drive tray • DW-F800- DB60 (power supply, contains BNST) • DW-F800- DB60C 3.5-inch LFF 60 4U (174.3 mm) Related references • Examples of supported VSP G400 configurations on page 19 16 Hitachi Virtual Storage Platform G400, G600 hardware overview Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

VSP G600 model

The VSP G600 is a highly reliable storage system that offers high storage capacity with full redundancy to better protect data and manage storage operations. The storage system consists of a 4U enclosure that includes two controllers, two optional NAS modules to support file operations. Drives are supported using drive trays connected to the controllers. The maximum number of drives supported is 576 (720 with dense intermix drive tray). The storage system supports 256 GB of high-speed cache memory. The DIMMs are arranged as 128 GB per controller. Storage system interfaces consist of: • 10-Gbps iSCSI: 28 ports per system (or 32 ports per systems for systems without drives or 12 ports per systems when NAS Modules are installed) • 10-Gbps iSCSI (Copper): 28 ports per system (or 32 ports per systems for systems without drives or 12 ports per systems when NAS Modules are installed) • 8-Gbps Fibre Channel: 56 ports per system (or 64 ports per systems for systems without drives or 24 ports per systems when NAS Modules are installed) • 16-Gbps Fibre Channel (2-port): 28 ports per system (or 32 ports per systems for systems without drives or 12 ports per systems when NAS Modules are installed) • 16-Gbps Fibre Channel (4-port): 56 ports per system (or 64 ports per systems for systems without drives or 24 ports per systems when NAS Modules are installed) • 32-Gbps Fibre Channel (4-port): 56 ports per system (or 64 ports per systems for systems without drives or 24 ports per systems when NAS Modules are installed) Controller Controller chassis Controller model Height CBLM DW800-CBL DW-F800-CTLM 4U (174.3 mm) Controller Model number Description NAS DW-F800-NAS Optional component for file storage configuration. NAS modules only provide file support. Hitachi Virtual Storage Platform G400, G600 hardware overview 17 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Drive tray model

name Supported drive type Number of drives supported Height SFF drive tray • DW-F800-DBS (power supply, contains BNST) • DW-F800- DBSC 2.5-inch SFF 24 2U (86.2 mm) LFF drive tray • DW-F800-DBL (power supply, contains BNST) • DW-F800- DBLC 3.5-inch LFF 12 2U (86.2 mm) FMD tray • DW-F800-DBF 5.25-inch FMD 12 2U (86.2 mm) Dense intermix drive tray • DW-F800- DB60 (power supply, contains BNST) • DW-F800- DB60C 3.5-inch LFF 60 4U (174.3 mm) Related references • Examples of supported VSP G600 configurations on page 19 Features The features described in the table are included with VSP G400 and VSP G600. Feature Value Maximum cache memory supported VSP G400:128 GB VSP G600: 256 GB Maximum number of spare drives 32 Maximum number of RAID groups VSP G400: 240 VSP G600: 240 Maximum volume size 3 TB (4 TB when using the LDEVs of other Storage Systems) Maximum number of volumes per RAID group 2,048 Maximum number of DP pool volumes 4,096 Maximum number of DP pools 64 Maximum number of iSCSI hosts connected through a network switch 255 18 Hitachi Virtual Storage Platform G400, G600 hardware overview Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Maximum number of Fibre Channel devices

connected through a Fibre Channel switch 255 Scalability All storage systems offer pay-as-you-grow scalability by allowing you to hot- add drives as you need them. Examples of supported VSP G400 configurations The following table lists the maximum number of drive trays and drives supported in a system configuration. A diskless configuration does not include any drive trays. Drive tray Maximum number of drive trays supported Maximum number of drives supported SFF drive tray 16 384 HDDs or SSDs LFF drive tray 16 192 HDDs or SSDs FMD tray 16 192 Hitachi Accelerated Flash (HAF) flash module drives Dense intermix drive tray 8 - Note: If a drive is inserted into a slot of a dense intermix drive tray when the installed number of drives exceeds 240 slots per path, the drive is blocked. Related references • VSP G400 model on page 15 Examples of supported VSP G600 configurations The following table lists the maximum number of drive trays and drives supported in a system configuration. A diskless configuration does not include any drive trays. Drive tray Maximum number of drive trays supported Maximum number of drives supported SFF drive tray 24 576 HDDs or SSDs LFF drive tray 24 288 HDDs or SSDs FMD drive tray 24 288 HAF flash module drives Dense intermix drive tray 12 - Hitachi Virtual Storage Platform G400, G600 hardware overview 19 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Note: If a drive is inserted into a slot of a dense intermix drive tray when the

installed number of drives exceeds 240 slots per path, the drive is blocked. Related references • VSP G600 model on page 17 Maximum number of mounted drive trays The following table lists the maximum number of mountable drive trays and mountable drives for each drive type. Note: If a drive is inserted into a slot of a dense intermix drive tray when the installed number of drives exceeds 240 slots per path, the drive is blocked. VSP G400 controller Drive trays Maximum number of trays Maximum number of drives CBLM SFF 16 384 HDDs or SSDs LFF 16 192 HDDs or SSDs FMD 16 192 FMDs (HAF) 4 48 FMDs FMD 1 8 FMDs + 1 spare (DC2) Dense intermix drive tray 8 480 HDDs or SSDs1 Note: 1The following SSD capacities (200 GB and 400 GB) are supported in a dense intermix drive tray. VSP G600 controller Drive trays Maximum number of trays Maximum number of drives CBLM SFF 24 576 HDDs or SSDs LFF 24 288 HDDs or SSDs FMD 24 288 FMDs (HAF) 4 48 FMDs FMD 2 16 FMDs + 1 spare (DC2) Dense intermix drive tray 12 720 HDDs or SSDs1 Note: 1The following SSD capacities (200 GB and 400 GB) are supported in a dense intermix drive tray. 20 Hitachi Virtual Storage Platform G400, G600 hardware overview Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Number of mounted drive trays

(Maximum 12 per path) Maximum number of mounted drives SFF, LFF drives Dense intermix drive tray SFF drive + dense intermix drive tray LFF drive + dense intermix drive tray CBLM 16 0 384 192 13 1 372 216 12 2 408 264 9 3 396 288 8 4 432 336 5 5 420 360 4 6 456 408 1 7 444 432 0 8 480 480 VSP G600 controller Number of mounted drive trays (Maximum 12 per path) Maximum number of mounted drives SFF, LFF drives Dense intermix drive tray SFF drive + dense intermix drive tray LFF drive + dense intermix drive tray CBLM 24 0 576 288 21 1 564 312 20 2 600 360 17 3 588 384 16 4 624 432 13 5 612 456 12 6 648 504 9 7 636 528 8 8 672 576 5 9 660 600 4 10 696 648 1 11 684 672 0 12 720 720 Hitachi Virtual Storage Platform G400, G600 hardware overview 21 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Hitachi Virtual Storage Platform G400, G600 hardware overview

Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Virtual Storage Platform G400, G600

controller The Virtual Storage Platform G400, G600 models are equipped with dual controllers for communicating with a data host. Each controller includes the following internal components such as a processor, dual in-line cache memory modules (DIMMs), cache flash memory (CFM), battery, and fans. The controller has an Ethernet connection for out- of-band management using Hitachi Device Manager - Storage Navigator. If the data path through one controller fails, all drives remain available to data hosts using a redundant data path through the other controller. The controller is equipped with LED indicators for monitoring its operating conditions and notifying possible component replacement. □ CBLM controller □ Host, Network, and Drive Tray Ports and LEDs Virtual Storage Platform G400, G600 controller 23 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

The CBLM controller includes specific functional LEDs located on the front and

rear of controller and power supplies to provide its operating status. CBLM with front panel bezel The following table describes the definitions of the CBLM controller front panel bezel LEDs. Number Item Description 1 POWER LED Green: Storage system is powered on. Amber: Storage system is receiving power. 2 READY LED Green: Normal operation. 3 WARNING LED Off: Normal operation. Amber: Component requires maintenance. Blink: Failure requires maintenance. Note: When System Option Mode 1097 is set to ON, the WARNING LED does not blink, even if the following failure service information messages (SIM) are issued: 452xxx, 462xxx, 3077xx, 4100xx, and 410100. LED might turn off during user maintenance. 4 ALARM LED Off: Normal operation. 24 Virtual Storage Platform G400, G600 controller Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Red: Processor failure (system

might be down). Go to the Customer Contact Us page at https://support.hds.com/ en_us/contact-us.html. 5 POWER ON/OFF (main switch) Powers the storage system. 6 Lock Locks and unlocks the front panel bezel by using the supplied key. Note: Removing a controller can cause the POWER, READY, WARNING, and ALARM LEDs on the front panel to turn off. These LEDs return to the on status after the storage system recovers from the controller replacement. CBLM front panel LEDs (without bezel) The following table describes the definitions of the CBLM controller front panel LEDs. Number Item Description 1 POWER ON/OFF (main switch) Powers the storage system. 2 POWER, READY, WARNING, and ALARM LEDs Note: When System Option Mode 1097 is set to ON, the WARNING LED does not blink, even if the following failure service information messages (SIM) are issued: 452xxx, 462xxx, 3077xx, 4100xx, and 410100. 3 Controllers Controller 1 (bottom) and Controller 2 (top). Virtual Storage Platform G400, G600 controller 25 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Green: Power restoration in

progress following power outage. Fast blink green: Restoring. Slow blink green: Restoring, or sequential shutdown in progress. 6 Cache flash memory N/A 7 ALM LED (for cache flash memory) Red: Cache flash memory can be removed. 8 CTL ALM LED Red: Controller can be removed. Blink red: Failure with the power supply unit of the controller. Amber: LAN reset switch was pressed. 9 LAN-RST switch Use only when instructed by customer support. 10 STATUS LED (for BKMF) Green: Charging of the battery in the backup module is complete. Red: Backup module can be removed. Blink red one time: Main battery failure. Blink red two times: Backup battery failure. Blink red three times: Both batteries failed or preventive maintenance replacement of batteries can run. Off: Battery is not mounted, battery-mounting failure occurred, or firmware is being upgraded. Off is normal status for configurations without batteries (for example, BKMF-10 and BKMF-20). CBLM rear panel The following table describes the definitions of the CBLM controller rear panel LEDs. 26 Virtual Storage Platform G400, G600 controller Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Power supply unit

2 Front end module 3 Back end module 4 LAN blade Rear view (includes NAS modules) Virtual Storage Platform G400, G600 controller 27 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Front end module

3 Back end module 4 LAN blade 5 Power supply unit CBLM power supply unit LEDs and connectors The following table lists the definitions of the CBLM power supply unit LEDs and connectors. Number Item Description 1 ALM/RDY LED Red: Power supply unit can be replaced. 2 Receptacle Connects to the power cable provided with the storage system. 3 RDY LED Green: Normal operation. Host, Network, and Drive Tray Ports and LEDs The controllers are equipped with specific interfaces for connecting, powering, configuring, and managing the storage system. The component LEDs display the operating status of the storage system. Front end module descriptions The front end module LEDs display the operating status of the module. 28 Virtual Storage Platform G400, G600 controller Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

10-Gbps iSCSI board LEDs and connectors (optical)

Number Item Description 1 STATUS LED Green: Front end module is in the power-on state. Red: Front end module can be removed safely. 2 PORT LED Red: Small form factor pluggable can be removed. Blue: Normal link status. Blink blue: Front end module is in communication status. 3 iSCSI connectors Connect to Ethernet LAN cables. 10-Gbps iSCSI board LEDs and connectors (copper) Virtual Storage Platform G400, G600 controller 29 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Green: Front end module is in

the power-on state. Red: Front end module can be removed safely. 2 PORT (Link/Speed) LED Yellow: 1-Gbps link. Green: 10-Gbps link. Off: No link connection. 3 PORT LED Green: Link connection is established. Blinking: Communication is in progress. Off: No link connection or not ready to communicate. 4 iSCSI connectors Connect to Ethernet LAN cables. 8-Gbps, 16-Gbps, or 32-Gbps Fibre Channel (4-port) board LEDs and connectors 30 Virtual Storage Platform G400, G600 controller Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Table 1 8-Gbps Fibre Channel

Number Item Description 1 Fibre Channel connectors Connect to Fibre Channel cables. 2 STATUS LED Green: Front end module is in power-on state. Red: Front end module can be removed safely. 3 PORT LED Red: Small form factor pluggable can be removed. Blue: Normal link status at 8- Gbps. Green: Normal link status at 2- Gbps or 4-Gbps. Table 2 32-Gbps, 16-Gbps Fibre Channel Number Item Description 1 Fibre Channel connectors Connect to Fibre Channel cables. 2 STATUS LED Green: Front end module is in power-on state. Red: Front end module can be removed safely. 3 PORT LED Red: Small form factor pluggable can be removed. Blue: Normal link status at 16- Gbps (16-Gbps). Blue: Normal link status at 32- Gbps (32-Gbps). Virtual Storage Platform G400, G600 controller 31 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Green: Normal link status at 4-

Gbps or 8-Gbps (16-Gbps). Green: Normal link status at 8- Gbps or 16-Gbps (32-Gbps). Port assignments CHB number 8-Gbps, 16-Gbps, or 32-Gbps Fibre Channel Ports (left to right) Port 1 Port 2 Port 3 Port 4 CHB-1A 1A 3A 5A 7A CHB-1B 1B 3B 5B 7B CHB-1C 1C 3C 5C 7C CHB-1D 1D 3D 5D 7D CHB-1E 1E 3E 5E 7E CHB-1F 1F 3F 5F 7F CHB-1G 1G 3G 5G 7G CHB-1H 1H 3H 5H 7H CHB-2A 2A 4A 6A 8A CHB-2B 2B 4B 6B 8B CHB-2C 2C 4C 6C 8C CHB-2D 2D 4D 6D 8D CHB-2E 2E 4E 6E 8E CHB-2F 2F 4F 6F 8F CHB-2G 2G 4G 6G 8G CHB-2H 2H 4H 6H 8H 16-Gbps Fibre Channel (2-port) board LEDs and connectors 32 Virtual Storage Platform G400, G600 controller Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Green: Front end module is in

the power-on state. Red: Front end module can be removed safely. 2 PORT LED Red: Small form factor pluggable can be removed. Blue: Normal link status at 16- Gbps. Green: Normal link status at 4- Gbps or 8-Gbps. 3 Fibre Channel connectors Connect to Fibre Channel cables. Port assignments CHB number 16-Gbps Fibre Channel Ports (left to right) Port 1 Port 2 CHB-1A 1A 3A CHB-1B 1B 3B CHB-1C 1C 3C CHB-1D 1D 3D CHB-1E 1E 3E CHB-1F 1F 3F CHB-1G 1G 3G CHB-1H 1H 3H CHB-2A 2A 4A CHB-2B 2B 4B CHB-2C 2C 4C CHB-2D 2D 4D CHB-2E 2E 4E CHB-2F 2F 4F CHB-2G 2G 4G CHB-2H 2H 4H LAN blade LEDs and connectors Virtual Storage Platform G400, G600 controller 33 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Green: Data is being

transferred. 2 LINK LED Green: Link status is normal. 3 LAN 2 LAN port used by the user. 4 LAN 1 Maintenance LAN port used by service personnel. 5 LAN ALARM LED Red: LAN blade can be removed. 6 Uninterruptible power supply (UPS) port N/A Back end module LEDs and connectors The back end module LEDs display the operating status of the module. 34 Virtual Storage Platform G400, G600 controller Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Green: Back end module is in

the power-on state. Red: Back end module can be removed safely. 2 Port LED Blue: Link status is normal. 3 PATH 0 connector Connect to a drive tray. 4 PATH 1 connector Connects to a drive tray. Virtual Storage Platform G400, G600 controller 35 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Virtual Storage Platform G400, G600 controller

Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Storage system drive trays

The drive trays contain drives, power supplies, fans, and status LEDs. Each drive tray provides interfaces for connecting to controllers and other drive trays. The all-flash storage arrays have various fixed storage capacity configurations with FMD DC2 flash storage devices. To deliver consistent low latency host response times and highest IOP performance across all host connection ports, conventional HDDs are not included or configurable with all-flash arrays. □ Small form-factor (SFF) drive tray □ Large form-factor (LFF) drive tray □ Flash module drive (FMD) tray □ Dense intermix drive tray □ SFF and LFF AC power supply unit LEDs and connectors Storage system drive trays 37 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Small form-factor (SFF) drive tray

SFF with front panel bezel Number Item Description 1 POWER LED Green: Drive tray is powered on. 2 READY LED Green: Drive tray is operational. 3 LOCATE LED Amber: • Indicates the location of the chassis. • Can be turned on or turned off by the maintenance utility. 4 Lock Locks and unlocks the front panel bezel by using the supplied key. SFF front panel without bezel 38 Storage system drive trays Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Green: Normal operation.

Blink green: Drive is being accessed. 2 ALM LED Red: Drive stopped due to a failure and can be replaced. 3 POWER, READY, and LOCATE LEDs Green: Drive tray is powered on. Green: Drive tray is operational. Amber: • Indicates the location of the chassis. • Can be turned on or turned off by the maintenance utility. 4 Small form factor drives The twenty-four 2.5-inch small form factor drives are positioned vertically. The slots are organized from 0 to 23. SFF rear panel Storage system drive trays 39 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Green: ENC is in the power-on

state. 3 LOCATE LED Amber: • Indicates the location of the chassis. • Can be turned on or turned off by the maintenance utility. 4 ALARM LED Red: ENC can be replaced. 5 PATH (IN) LED Blue: IN side port is linked up. 6 PATH (IN) connector Connects to a controller or drive tray. 7 PATH (OUT)LED Blue: OUT side port is linked up. 8 PATH (OUT) connector Connects to a drive tray. 9 Console This port is reserved. 10 Power supply unit N/A 11 Receptacle Connects to the power cable provided with the storage system. 12 AC IN LED Green: Normal operation. 13 ALM LED Red: Power supply unit can be replaced. 14 RDY LED Green: Normal operation. Large form-factor (LFF) drive tray LFF with front panel bezel 40 Storage system drive trays Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Green: Drive tray is powered

on. 2 READY LED Green: Drive tray is operational. 3 LOCATE LED Amber: • Indicates the location of the chassis. • Can be turned on or turned off by the maintenance utility. 4 Lock Locks and unlocks the front panel bezel by using the supplied key. LFF front panel without bezel Number Item Description 1 POWER, READY, and LOCATE LEDs Green: Drive tray is powered on. Green: Drive tray is operational. Amber: Storage system drive trays 41 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Indicates the location of the

chassis. • Can be turned on or turned off by the maintenance utility. 2 ACT LED Green: Normal operation. Blink green: Drive is being accessed. 3 ALM LED Red: Drive stopped due to a failure and can be replaced. 4 Large form factor drives The twelve 3.5-inch large form factor drives are positioned horizontally. The slots are organized in the following order: 8 9 10 11 4 5 6 7 0 1 2 3 LFF rear panel Number Item Description 1 ENC N/A 2 POWER LED Green: ENC is in the power-on state. 3 LOCATE LED Amber: • Indicates the location of the chassis. • Can be turned on or turned off by the maintenance utility. 4 ALARM LED Red: ENC can be replaced. 5 PATH (IN) LED Blue: IN side port is linked up. 42 Storage system drive trays Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

PATH (IN) connector

Connects to a controller or drive tray. 7 PATH (OUT)LED Blue: OUT side port is linked up. 8 PATH (OUT) connector Connects to a drive tray. 9 Console This port is reserved. 10 Power supply unit N/A 11 Receptacle Connects to the power cable provided with the storage system. 12 AC IN LED Green: Normal operation. 13 ALM LED Red: Power supply unit can be replaced. 14 RDY LED Green: Normal operation. Flash module drive (FMD) tray FMD with front panel bezel Number Item Description 1 POWER LED Green: Drive tray is powered on. 2 READY LED Green: Drive tray is operational. 3 LOCATE LED Amber: • Indicates the location of the chassis. • Can be turned on or turned off by the maintenance utility. Storage system drive trays 43 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Locks and unlocks the front

panel bezel by using the supplied key. FMD front panel without bezel Number Item Description 1, 2 ACT LED Green: Normal operation. Blink: Drive is being accessed. Slow blink: • DKC-F710I-1R6FM/3R2FM: Insufficient battery capacity in the flash module drive. • DKC-F810I-1R6FN/3R2FN/ 6R4FN: Flash module drive built-in capacitor is charged. If the storage system is turned on, the LED stops blinking when the capacitor is finished charging (approximately two minutes). Note: ACT indicator is only printed on some types of FMDs. 44 Storage system drive trays Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Red: Drive stopped due to a

failure and can be replaced. Note: ACT indicator is only printed on some types of FMDs. 3 POWER, READY, and LOCATE LEDs Green: Drive tray is powered on. Green: Drive tray is operational. Amber: • Indicates the location of the chassis. • Can be turned on or turned off by the maintenance utility. 4 Flash module drives Twelve flash module drives. Slots are organized the following way: 9, 10, 11 6, 7, 8 3, 4, 5 0, 1, 2 FMD rear panel Number Item Description 1 ENC N/A 2 POWER LED Green: ENC is in the power-on state. 3 LOCATE LED Amber: Storage system drive trays 45 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Indicates the location of the

chassis. • Can be turned on or turned off by the maintenance utility. 4 ALARM LED Red: ENC can be replaced. 5 PATH (IN) LED Blue: IN side port is linked up. 6 PATH (IN) connector Connects to a controller or drive tray. 7 PATH (OUT)LED Blue: OUT side port is linked up. 8 PATH (OUT) connector Connect to a drive tray. 9 Console This port is reserved. 10 Receptacle Connects to the power cable provided with the storage system. 11 Three LEDS, top to bottom: RDY LED AC IN LED ALM REPLACE LED Green: Power supply unit is operating normally. Green: Power supply unit is operating normally. Red: Power supply unit can be replaced. Dense intermix drive tray Dense intermix drive tray with front panel bezel 46 Storage system drive trays Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Green: Drive tray is powered

on. 2 READY LED Green: Drive tray is operational. 3 LOCATE LED Amber: • Indicates the location of the chassis. • Can be turned on or turned off by the maintenance utility. 4 Lock Locks and unlocks the front panel bezel by using the supplied key. Dense intermix drive tray display LEDs Number Item Description 1 ACT Green: Normal operation. Blink green: Drive is being accessed. 2 ALM LED Red: Drive stopped due to a failure and can be replaced. Storage system drive trays 47 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Note: At the rear of the drive tray, the drives are organized from left to right.

On the left side of the preceding figure, the rear of the drive tray is at the top. • Rear of drive tray: 48-59 • 36-47 • 24-35 • 12-23 • Front of drive tray: 00-11 Dense intermix drive tray rear panel Number Item Description 1 Power supply unit N/A 2 RDY LED Green: Normal operation. 3 AC IN LED Green: Normal operation. 4 ALM LED Red: Power supply unit can be replaced. 5 Receptacle Connects to the power cable provided with the storage system. 6 ENC N/A 7 PATH (OUT)LED Blue: OUT side port is linked up. 8 PATH (OUT) connector Connect to a drive tray. 9 PATH (IN) LED Blue: IN side port is linked up. 10 PATH (IN) connector Connects to a controller or drive tray. 48 Storage system drive trays Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

This port is reserved.

12 ALARM LED Red: ENC can be replaced. 13 LOCATE LED Amber: • Indicates the location of the chassis. • Can be turned on or turned off by the maintenance utility. 14 POWER LED Green: ENC is in the power-on state. SFF and LFF AC power supply unit LEDs and connectors Both SFF and LFF drive trays are equipped with AC power supply units. The AC power supply units include LEDs to display its operating status. Number Item Description 1 RDY LED Green: Normal operation. 2 AC IN LED Green: AC input is operating normally. 3 ALM LED Red: Power supply unit can be replaced. Storage system drive trays 49 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Host port expansion chassis

The host port expansion chassis contains various interconnect adapters that connect a host system to storage and other network devices. The interconnect adapters include PCIe boards, iSCSI and FC cards. For more information, contact customer support. □ Host port expansion chassis front panel bezel LEDs □ PCIe switchboard □ Host port expansion chassis fan □ PCIe cable connector □ Host port expansion chassis power supply Host port expansion chassis 51 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Host port expansion chassis front panel bezel LEDs

Number Item Description 1 POWER LED Green: Host port expansion is turned on. Amber: PCIe module is turned on. Off: PCIe module is turned off. 2 Safety lock Lock or unlock the front bezel. PCIe switchboard 52 Host port expansion chassis Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Green: PCIe switchboard is

powered on. Red: PCIe switchboard can be replaced safely. Off: PCIe switchboard is powered off. Host port expansion chassis fan Number Item Description 1 ALM LED Red: Fan failure has occurred. Off: Normal operation. PCIe cable connector Host port expansion chassis 53 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Green: PCIe cable connector is

powered on. Red: PCIe cable connector can be replaced safely. Off: PCIe cable connector is powered off. 2 Link Basic LED Green: Basic PCIe Gen-3.0 (8- Gbps) is linked up normally. Off: Basic PCIe is not linked up (PCIe cable might not be connected). If a cable is connected, it can be removed safely. 3 InAct Basic LED Amber: Basic PCIe status changed from link up to link down and cables. Cables can be removed safely. Off: Basic PCIe is normal or not set. 4 Link Option LED Green: Option PCIe Gen-3.0 (8- Gbps) is linked up normally. Off: Option PCIe is not linked up (PCIe cable might not be 54 Host port expansion chassis Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

connected). If a cable is

connected, it can be removed safely. 5 InAct Option LED Amber: Option PCIe status changed from link up to link down and cables. Cables can be removed safely. Off: Option PCIe is normal or not set. Host port expansion chassis power supply Number Item Description 1 ALM/RDY LED Red: Host port expansion chassis power supply can be replaced safely. Green: Normal operation. 2 AC IN LED Blue: AC input is normal. Host port expansion chassis 55 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Host port expansion chassis

Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

The NAS module provides communication ports to support file system

protocols in a block- or file-system configuration. Note: The NAS module is not supported on the VSP G200 storage system. □ NAS Module Ports and LEDs NAS module 57 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

NAS Module Ports and LEDs

Legend Name Color Description 1 User LAN port - This is used with the file level access. 1. Target group 1 2. Target group 2 3. Target group 3 4. Target group 4 5. Target group 5 6. Target group 6 2 Cluster port - Reserved for future use 3 Status LED Green NAS modules are functioning normally. Red NAS modules can be removed. 4 Link LED Blue Displays link status. 5 Fail LED Red A failure has occurred. 58 NAS module Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

VSP service processor server

The VSP Gx00 models include a separate, dedicated 1U service processor (SVP) to host an element manager (Storage Navigator). The SVP (model number 3919435.P) operates independently from the CPU of the storage system and operating system, and provides out‑of‑band configuration and management of the storage system. The SVP also monitors and collects performance data for key components of the storage system to enable diagnostic testing and analysis for customer support. The SVP is available as: • A physical 1U management server provided by Hitachi Data Systems that runs Windows Embedded Standard 7. • A software application that runs Windows 7 Professional x64 Service Pack 1 (64-bit) on a customer-supplied server hardware, a VMware ESXi host, or Linux KVM host. • A software application that runs Microsoft Hyper-V Windows Server 2012 R2 on a customer-supplied server hardware running one of the following 64-bit operating systems: ○ Windows 10 Professional ○ Windows 10 Enterprise ○ Windows Server 2012 ○ Windows Server 2012 R2 □ Service processor description □ SVP front panel □ SVP rear panel □ Service processor hardware specifications VSP service processor server 59 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Service processor description

The SVP provides four RJ-45 ports: • Two ports connect to the storage system controllers (one port for each controller). • One port connects to the IP network of the user. • One port connects to a user-supplied management console PC. Note: This product is also designed for IT power distribution systems with phase-to-phase voltage. Three of the four RJ-45 ports (which connect to the controllers and the IP network) are configured as a bridge. The SVP can be addressed using the default IP address 192.168.0.15. In the unlikely event you cannot connect to the SVP using the default IP address, use the following emergency login: http:///dev/storage// emergency.do. For example: Storage system model number Storage system serial number URL 8320004 456789 http://192.168.0.15/dev/ storage/8320004456789/ emergency.do 8340004 456789 http://192.168.0.15/dev/ storage/8340004456789/ emergency.do 8360004 456789 http://192.168.0.15/dev/ storage/8360004456789/ emergency.do Users are responsible for adopting the appropriate security procedures with the SVP, including: • Applying Windows security patches. • Turning on automatic Windows updates or using the manual Windows update method. • Installing antivirus software that has been tested and approved by Hitachi. SVP front panel The front panel of the physical SVP is equipped with LEDs, a reset button, and a power button. 60 VSP service processor server Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

LEDs. From left to right, the LEDs are:

• BMC Heartbeat • LAN card 2 • LAN card 1 • Hard drive • System standby power 2 Reset button. 3 Power button. Applies power to or removes power from the SVP. SVP rear panel The only ports used on the rear panel of the physical SVP are the power socket and the four LAN ports. Number Description 1 Power socket. Attach the power cable supplied with the SVP. 2 Four LAN ports arranged as follows: LAN3 LAN4 LAN1 LAN2 VSP service processor server 61 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

These ports connect to your IP network, the

management console PC, and the user LAN port on each storage system controller. Note: After the Initial Startup Wizard is run, the SVP can be used in non- bridge mode. In this mode, the cables can be removed from SVP ports LAN3 and LAN4 and attached to switches. For more information, contact customer support. Service processor hardware specifications The following table lists the hardware specifications for the service processor (SVP) provided by Hitachi Data Systems. Caution: The SVP is not supported in high-temperature environments. Do not operate it in locations with temperatures of 40°C or higher. Item Specification Dimensions Height: 1.7 inches (43 mm) Width: 17.2 inches (437 mm) Depth: 14.5 inches (369 mm) Weight: 14 lbs (6.4 kg) Processor Celeron G1820 2.7-GHz 2M, 2C, 2T • Cores: 2 • Instruction set: 64-bit • SmartCache: 2 MB • Maximum memory size: 32 GB • Memory types: DDR3-1333, DDR3L-1333 @ 1.5V Memory 8-GB RAM DDR3 Hard drive 2 TB Network interface card x4 ports (on-board NIC) + x1 IPMI (BMC) port Fans 2 x 4-cm 4-pin PWM fans Operating system Windows Embedded Standard 7 62 VSP service processor server Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Maintaining the storage system

Ongoing proper maintenance of the storage system maintains the reliability of the storage system and its constant availability to all hosts connected to it. For more complex maintenance activities, contact customer support. □ Storing the storage system □ Powering off the storage system □ Removing cables Maintaining the storage system 63 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Storing the storage system

If the storage system does not receive power for more than six months, the battery can become discharged and possibly damaged. To avoid this situation, charge the battery for more than three hours at least once every six months. Note: Do not store the equipment in an environment with temperatures of 104ºF (40ºC) or higher because battery life will be shortened. Powering off the storage system Procedure 1. Press the main switch for three seconds until the POWER LED blinks. 2. Verify the POWER LED on the front of the storage system changes from green to amber. Wait 25 minutes to 4 hours for the POWER LED to turn amber, depending on the system configuration (check after 33 minutes). 3. To stop the power supply, remove the power cables from the power supply units on the controller chassis and drive box. If the storage system is connected to a PDU, you can stop the power supply by turning off the PDU breaker. Note: If the storage system does not receive power for more than six months, the battery can become discharged and possibly damaged. To avoid this situation, charge the battery for more than three hours at least once every six months. Removing cables Observe the following instructions when removing cables form the storage system. To remove a SAS cable, pull the tab of the SAS cable (1) to release the latch and remove the SAS cable (2). 64 Maintaining the storage system Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

To remove an optical cable, push the top of the connector of the optical cable

(1) to release the latch and remove the SAS cable (2). To remove a LAN cable, push the top of the LAN cable connector (1) to release the latch and remove the LAN cable (2). Maintaining the storage system 65 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Maintaining the storage system

Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Mechanical specifications for VSP G400,

G600 The storage system mechanical specifications are described for VSP G400, G600 . □ VSP G400 and VSP G600 mechanical specifications Mechanical specifications for VSP G400, G600 67 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

VSP G400 and VSP G600 mechanical specifications

Controller Quantity Component Description 1 CBLM A 4U controller chassis consisting of controllers, channel boards, disk boards, NAS module (optional), AC or DC power supplies, and batteries with cooling fans. Drive trays Quantity Component Description 1 SFF drive tray A drive tray that supports 2.5- inch disk drives and 2.5-inch flash drives. The drive tray consists of an ENC, cooling fans, and AC-DC power supplies or DC-DC power supplies. 1 LFF drive tray A drive tray that supports 3.5- inch disk drives and 3.5-inch flash drives. The drive tray consists of an ENC, cooling fans, and AC-DC power supplies or DC-DC power supplies. 1 FMD tray A drive tray that supports flash module drives and consists of an ENC and AC-DC power supplies equipped with built-in cooling fans. 1 Dense intermix drive tray A drive chassis that supports a variety of drive types such as 2.5-inch drives, 3.5-inch drives, and flash drives. The chassis consists of an ENC and AC-DC power supplies equipped with built-in cooling fans. NAS module Component Description NAS module Optional component for block and file storage configuration 68 Mechanical specifications for VSP G400, G600 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

2.5-inch drive (SFF)

3.21 x 8.10 x 0.74 inches (81.6 x 205.7 x 18.7 mm) 3.5-inch drive (LFF and dense intermix drive tray) 4 x 5.78 x 1.02 inches (101.6 x 147.0 x 26.1 mm) Flash Module Drive (flash module drive tray) 5.74 x 14.44 x 0.78 inches (146 x 366.8 x 19.8 mm) Data capacity (GB) Component Specification 2.5-inch drive (SFF) 196.92, 288.20, 393.85, 472.61, 576.39, 945.23, 1152.79, 1729.29, 1890.46, 3780.92 GB 3.5-inch drive (LFF and dense intermix drive tray) 393.85, 1152.79, 1729.29, 3916.14, 5874.22, 9790.36 GB Flash Module Drive (flash module drive tray) 1759.21, 3518.43 , 7036.87, 14073.74 GB Rotational speed (min-1) Component Specification 2.5-inch drive (SFF) 288.20 GB: 15,000 RPM 576.39 GB: 10,000 or 15,000 RPM 1152.79 GB: 10,000 RPM 1729.29 GB: 10,000 RPM 3.5-inch drive (LFF and dense intermix drive tray) 3916.14 GB: 7,200 RPM 5874.22 GB: 7,200 RPM 9790.36 GB: 7,200 RPM Maximum mountable quantity Mixing SFF, LFF, FMD, and dense intermix drive trays might affect the maximum number of drives that can be mounted. Component Specification SFF 24 LFF 12 Mechanical specifications for VSP G400, G600 69 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Flash module drive (flash module drive tray)

12 Dense intermix drive tray 60 Battery specifications Storage system intake temperature CBLM Up to 75.2º F (24º C) 5 years Up to 86º F (30º C) 5 years Up to 93.2º (34º C) 4 years Up to 104º (40º C) 3 years Host interface Item Component Specification Interface type Fibre Channel optical 8-Gbps, 16-Gbps, 32-Gbps iSCSI optical 10-Gbps iSCSI copper 10-Gbps NAS module 10-Gbps (Fibre Channel optical) Data transfer speed (maximum speed for transfer to host) Fibre Channel optical 800-Mbps (Fibre Channel) 1600-Mbps (Fibre Channel) 3200-Mbps (Fibre Channel) iSCSI optical 10-Gbps (iSCSI optical) iSCSI copper 10-Gbps (iSCSI copper) NAS module (Fibre Channel) 1000 Mbs Number of ports 8-Gbps Fibre Channel optical 64 16-Gbps Fibre Channel optical (2-port) 32 16-Gbps Fibre Channel optical (4-port) 64 32-Gbps Fibre Channel optical (4-port) 64 10-Gbps optical iSCSI 32 10-Gbps copper iSCSI 32 Number of ports (NAS Module not installed) 8-Gbps Fibre Channel optical 64 16-Gbps Fibre Channel optical (2-port) 32 16-Gbps Fibre Channel optical (4-port) 64 70 Mechanical specifications for VSP G400, G600 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

32-Gbps Fibre Channel optical

(4-port) 64 10-Gbps optical iSCSI 32 10-Gbps copper iSCSI 32 Number of ports (NAS Module installed) 8-Gbps Fibre Channel optical 24 16-Gbps Fibre Channel optical (2-port) 12 16-Gbps Fibre Channel optical (4-port) 24 32-Gbps Fibre Channel optical (4-port) 24 10-Gbps optical iSCSI 12 10-Gbps copper iSCSI 12 10-Gbps Fibre Channel optical 12 Transferred block size 512 bytes Maximum number of hosts using a Fibre Channel switch 255 Maximum number of hosts using a network switch 255 RAID specifications D: Data drive, P: Parity drive. Although the storage system with a configuration of RAID 1, RAID 5, or RAID 6 provides data reliability enhanced by redundancy, there is a chance that user data could be lost due to an unexpected host, storage system hardware, or software failure. Therefore, users are requested to back up all data. RAID Level SAS, SAS 7.2k, flash drives mounted RAID 1 2D+2D, 4D+4D RAID 5 3D+1P, 4D+1P, 6D+1P, 7D+1P RAID 6 6D+2P, 12D+2P, 14D+2P Item Specification Maximum number of RAID groups VSP G400:160 VSP G600:240 Maximum volume size 3 TB (or 4 TB when using the LDEVs of other storage systems) Maximum volumes/host groups and iSCSI targets 2048 Maximum number of volumes per RAID group 2048 Mechanical specifications for VSP G400, G600 71 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Shared memory and data assurance

Item Specification Flash memory 32 MB L3 Cache memory 4 MB SDRAM 1 GB Data bus Parity Cache memory ECC (1 bit for correction, 2 bits for detection) Drive Data assurance code Start-up time Item Standard: 5-to-8 minutes. The start-up time may be longer in proportion to the number of drive trays connected. With a maximum configuration 1 controller tray and 19 drive trays, start-up time is approximately 8 minutes. Chassis size Component Specification (WxDxH) CBLM 19.01 x 35.10 x 6.86 inches (483 x 891.7 x 174.3 mm) SFF/LFF 18.97 x 22.24 x 3.47 inches (482 x 565 x 88.2 mm) DBF 19.01 x 30 x 3.42 inches (483 x 762 x 87 mm) Dense intermix drive tray 18.97 x 40.51 x 6.92 inches (482 x 1,029 x 176 mm) (includes the depth of the cable-management arms) Mass The table lists the values of a maximum configuration when all controllers and drives are mounted. Component Specification CBLM 187.39 pounds (85 kg) SFF Approx 50.70 inches (23 kg) LFF Approx 59.52 inches (27 kg) DBF Approx. 83.77 pounds (38 kg) 72 Mechanical specifications for VSP G400, G600 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Dense intermix drive tray

Approx. 198.41 pounds (90 kg) Required height Component Specification CBLM 4 U SFF 2 U LFF 2 U DBF 2 U Dense intermix drive tray 4 U If a drive is inserted into a slot of a dense intermix drive tray when the installed number of drives exceeds 240 slots per path, the drive is blocked. Cache specifications Item Specification Capacity (GB) VSP G400: 128 VSP G600: 256 NAS module Cache Capacity DDR3 DIMM 8GB x 12 [Slot] Note: • All 12 slots must be fully installed with DIMMs. • Each DIMM is replaceable when they fail. • The DIMM is not common and cannot be used with DKC DIMM. Control method Read LRU, Write after Battery backup Provided Backup duration Unrestricted (saving to a nonvolatile memory) Data in the cache memory is preserved against power failures. If a power outage occurs, data in cache memory is written to drives. When the storage system enters Cache Backup mode, the amber WARNING LED goes on to when the system starts. This warning indicates that the battery charge has dropped significantly and the remaining battery capacity is not sufficient; the storage system will continue operating with the Write Cache function disabled. When the battery is charged, the warning indication disappears, and the storage system continues the operation in the Write Cache function. Mechanical specifications for VSP G400, G600 73 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

The warning indication disappears within six hours. Even when the warning is

shown, normal operation is assured in Write-Through. Read and write performance is lowered because the Write Cache function is disabled. If the storage system is not charged for more than six months, the battery can become overcharged and sustain unrecoverable damage. To avoid this situation, charge the battery more than 3 hours every six months. Insulation performance Item Specification Insulation withstand voltage AC 1,500 V (100 mA, 1 min) Insulation resistance DC 500 V, 10 M Ω or more 74 Mechanical specifications for VSP G400, G600 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Electrical specifications for VSP G400,

G600 The electrical specifications are described for the storage systems. □ Electrical specifications Electrical specifications for VSP G400, G600 75 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Input voltage (operable voltage

range) (V) AC 200-240 +6%/-11% SFF, LFF, FMD, and dense intermix drive tray: AC 200-240 +6%/-11% Frequency (Hz) 50/60 ±1 Number of phases, cabling Single-phase with protective grounding Steady-state current 100V/ 200V1, 2 CBLM: 4.0x2 SFF drive tray: 2.4x2/1.2x2 LFF drive tray: 1.9x2/1.0x2 FMD drive tray: 2.6x2/1.3x2 Dense intermix drive tray: -/ 3.0x2 Current rating of breaker/fuse (A) 16.0 (each electrical) Heat value (normal) (kJ/h) CBLM: 2160 or less SFF drive tray: 1120 or less LFF drive tray: 940 or less FMD drive tray: 1520 or less Dense intermix drive tray: 3460 or less Steady-state power (VA/W)3 CBLM: 1600/1560 or less SFF drive tray: 480/460 or less LFF drive tray: 380/350 or less FMD drive tray: 520/490 or less Dense intermix drive tray: 1200/1160 or less Power consumption (VA/W) CBLM: 640/600 or less SFF drive tray: 320/310 or less LFF drive tray: 280/260 or less FMD drive tray: 440/420 or less Dense intermix drive tray: 1000/960 or less Notes: 1. The power current of Nx2 described in this table is required for a single power unit. 2. If one power unit fails, another power unit requires electric current for the two power units. Therefore, plan the power supply facility so that the current-carrying capacity for one power unit can provide the total capacity for two power units. 3. This table shows the power requirement (100 V or 200 V) for the maximum configuration . The actual required power might exceed the value shown in the table when the tolerance is included. 76 Electrical specifications for VSP G400, G600 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Environmental specifications for VSP

G400, G600 The environmental specifications are described for the storage systems. □ Environmental specifications Environmental specifications for VSP G400, G600 77 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Caution: The following VSP Gx00/Fx00 storage system components are not

supported in high-temperature environments. Do not operate the following components at temperatures of 40°C or higher: • DB60 dense drive tray • HDS provided service processor (SVP) server • First-generation FMDs (non-DC2 FMDs) State Controller SFF, LFF drive trays Dense intermix drive tray Operating 50°F to 104°F (10°C to 40°C) 50°F to 104°F (10°C to 40°C) 50°F to 95°F (10°C to 35°C) Non-operating 14°F to 122°F (-10°C to 50°C) 14°F to 122°F (-10°C to 50°C) 14°F to 122°F (-10°C to 50°C) Transport, storage -22°F to 140°F (-30°C to 60°C) -22°F to 140°F (-30°C to 60°C) -22°F to 140°F (-30°C to 60°C) Temperature change rate (°C/h) 10 or less State Controller FMD drive trays Operating 50°F to 104°F (10°C to 40°C) DKC-F710I-1R6FM or DKC-F710I-3R2FM drive is installed: 50°F to 95°F (10°C to 35°C) Operating 50°F to 104°F (10°C to 40°C) DKC-F810I-1R6FN/3R2FN/6R4FN/7R0FP/14RFP drive is installed: 50°F to 104°F (10°C to 40°C) Non-operating 14°F to 122°F (-10°C to 50°C) 14°F to 95°F (-10°C to 35°C) Transport, storage -22°F to 140°F (-30°C to 60°C) -22°F to 122°F (-30°C to 50°C) Temperature change rate (°C/h) 10 or less Humidity State Percentage Operating 8 to 80 78 Environmental specifications for VSP G400, G600 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

8 to 90

Transport, storage (%) 5 to 95 Maximum wet bulb temperature (°C) 29 (non-condensing) Vibration State m/s2 Operating 2.5 or less Within 5 seconds (resonance point: 10 Hz or less) Non-operating 5.0 or less at 5 Hz to 300 Hz (no damage to product) 9.8 (1.0 G) Within 5 seconds (resonance point: 10 Hz or less) Transport (packed) 5.0 or less Impact State m/s2 Operating 20 or less (10 ms, half sine wave) Non-operating 50 or less (10 ms, half sine wave) Transport (packed) 80 or less Altitude State Controller FMD drive Operating (m) 3,000 (Environmental temperature: 10°C to 32°C) 900 (Environmental temperature: 10°C to 40°C) 3,000 (Environmental temperature 10°C to 32°C) OR 900 (Environmental temperature: 10°C to 35°C) when DKC-F710I-1R6FM or DKC-F710I-3R2FM drive is installed. Operating (m) 3,000 (Environmental temperature: 10°C to 32°C) 3,000 (Environmental temperature: 10°C to 32°C) OR Environmental specifications for VSP G400, G600 79 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

10°C to 40°C)

900 (Environmental temperature: 10°C to 40°C) when DKC-F810I-1R6FN/3R2FN/6R4FN/7R0FP/14RFP drive is installed. Non-operating (m) -60 to 12,000 N/A State Controller SFF and LFF drives Dense intermix drive tray Operating (m) 3,000 (Environmenta l temperature: 10°C to 32°C) 3,000 (Environmental temperature: 10°C to 32°C) 3,000 (Environmental temperature: 10°C to 28°C) 1,000 (Environmental temperature: 10°C to 35°C) 900 (Environmenta l temperature: 10°C to 40°C) 900 (Environmental temperature: 10°C to 40°C) Non-operating (m) N/A Atmosphere Avoid areas exposed to corrosive gas and salty air. Acoustic Noise State Controller SFF, LFF Dense intermix drive tray Operati ng 60 dB (Environmental temperature 32°C or less)1 60 dB (Environmental temperature 32°C or less)1 71 dB (Environmental temperature 32°C or less)1, 2, 3, 4 Non- operati ng 55 dB 55 dB 71 dB (Environmental temperature 32°C or less)1, 2, 3, 4 Notes: 1. The system's internal temperature controls the rotating speed of the fan module. Therefore, this standard value might be exceeded if the maximum load continues under high- temperature environment or if a failure occurs in the system. 2. Sound pressure level (LA) changes from 66 dB or 75 dB, according to the ambient temperature, drive configuration, and operating status. Maximum volume can reach 79 dB during maintenance procedure for a failed ENC or power supply. 3. Acoustic power level (LwA) measured by the ISO 7779 standard is 7.2 B. This value changes from 7.2 B to 8.1 B, according to the ambient temperature, drive configuration, and operating status. 4. When accessing the dense intermix drive tray, do not work for long times at the rear of the rack. 80 Environmental specifications for VSP G400, G600 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

60 dB (Environmental temperature

32°C or less)1 60 dB (Environmental temperature 32°C or less)1, 2, 3 (When accessing the dense intermix drive tray, do not work for long times at the rear of the rack.) Non- operati ng 55 dB (Environmental temperature 32°C or less)1, 2, 3, 4 55 dB Notes: 1. The system's internal temperature controls the rotating speed of the fan module. Therefore, this standard value might be exceeded if the maximum load continues under high- temperature environment or if a failure occurs in the system. 2. Sound pressure level (LA) changes from 66 dB or 75 dB, according to the ambient temperature, drive configuration, and operating status. Maximum volume can reach 79 dB during maintenance procedure for a failed ENC or power supply. 3. Acoustic power level (LwA) measured by the ISO 7779 standard is 7.2 B. This value changes from 7.2 B to 8.1 B, according to the ambient temperature, drive configuration, and operating status. Environmental specifications for VSP G400, G600 81 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Environmental specifications for VSP G400, G600

Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

iSCSI standards and specifications

The following tables describe the standards and specifications for using iSCSI in a hosting environment. □ iSCSI standards □ iSCSI specifications iSCSI standards and specifications 83 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

The following standards apply to the management, maintenance, and iSCSI

data ports. To configure this system, use switches that comply with the following standards: • IEEE 802.1D STP • IEEE 802.1w RSTP • IEEE 802.3 CSMA/CD • IEEE 802.3u Fast Ethernet • IEEE 802.3z 1000 BASE-X • IEEE 802.1Q Virtual LANs • IEEE 802.3ae 10 Gigabit Ethernet • RFC 768 UDP • RFC 783 TFTP • RFC 791 IP • RFC 793 TCP • RFC 1157 SNMP v1 • RFC 1231 MIB II • RFC 1757 RMON • RFC 1901 SNMPv2 iSCSI specifications Item Specification Comments iSCSI target function Supported N/A iSCSI target function Supported TrueCopy® only iSCSI ports 2 per interface board VSP Gx00 models: Maximum 32 per iSCSI system Connection methods Direct and switch connections Host connections 255 (maximum per iSCSI port) With Linux software initiator, the maximum number decreases. Path failover HDLM1 Supports Microsoft MPIO (Multi Path I/O) Link 10 Gbps SFP+ N/A Transfer speed 10 Gbps N/A Connector type LC N/A Cable Optical OM3, OM2 MMF cable N/A Network switch L2 or L3 switch Should comply with IEEE802.3ae 84 iSCSI standards and specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Maximum: 5 switches or fewer

Minimum number of cascading switches is recommended. MAC address Per port (fixed value) Factory setting: World Wide Unique value. Cannot be changed. Maximum transfer unit (MTU) 1,500, 4,500, 9,000 bytes (Ethernet frame) Jumbo frame, MTU size greater than 1500 Link aggregation Not supported N/A Tagged VLAN Supported N/A IPv4 Supported N/A IPv6 Supported Note the following precautions: • When iSCSI Port IPv6 is set to Enabled, if the IPv6 global address is set to automatic, the address is determined by acquiring a prefix from an IPv6 router. • If the IPv6 router does not exist in the network, the address cannot be determined. As a result, an iSCSI connection might be delayed. When an iSCSI Port IPv6 is set to Enabled, verify the IPv6 router is connected to the same network, and then set IPv6 global address automatically. Subnet mask Supported N/A Gateway address Supported N/A DHCP N/A N/A DNS N/A N/A Ping (ICMP ECHO) Transmit, Receive Supported N/A IPsec2 N/A N/A TCP port number 3260 Changeable among 1 to 65,535. Observe the following if changing values: • The setting of the corresponding host should also be changed to log in the new port number. • The new port number might conflict with other network communication or be iSCSI standards and specifications 85 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

filtered on some network

equipment, preventing the storage system from communicating through the new port number. iSCSI name Both iqn3 and eui4 types are supported The unique iqn value is automatically set when a target is made. iSCSI name is configurable. Error recovery level 0 (zero) Error recovery by retrying from host. Does not support Level 1 and Level 2. Header digest Supported Detects header error or data error with iSCSI communication. The storage system follows the host's digest setting. If digest is enabled, the performance degrades. The amount of the degradation depends on factors such as host performance of host and transaction pattern. Data digest Supported Maximum iSCSI connections at one time 255 per iSCSI port N/A CHAP Supported Authentication: login request is sent properly from host to storage. CHAP is not supported during discovery session. Mutual (2-way) CHAP Supported (not available if connected to Linux software initiator) Authentication: login request is sent properly from host to storage. CHAP user registration Max 512 users per iSCSI port N/A iSNS Supported With iSNS (name service), a host can discover a target without knowing the target's IP address. Note: 1. JP1, HiCommand Dynamic Link Manager. Pass switching is achieved. Not supported on Windows Vista and Windows 7 operating systems. 2. IP Security. Authentication and encryption of IP packets. The storage system does not support IPsec. 3. iqn: iSCSI Qualified Name. The iqn consists of a type identifier, "iqn," a date of domain acquisition, a domain name, and a character string given by the individual who acquired the domain. Example: iqn.1994-04.jp.co.hitachi:rsd.d7m.t.10020.1b000.tar 4. eui: 64-bit Extended Unique Identifier. The eui consists of a type identifier, "eui," and an ASCII-coded, hexadecimal, EUI-64 identifier. Example: eui.0123456789abcdef 86 iSCSI standards and specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Part replacement is essential for maintaining the high performance of the

system. Replacing system components is covered by the maintenance service contract. □ Battery unit Replacement parts 87 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Use the storage system in a place where the ambient temperature is 86°F

(30°C) or less on average. Periodic parts replacement is required. For customers with maintenance service contracts, parts are replaced periodically in keeping with the terms of the contract. Note: The battery protects the data in the cache memory in an emergency, such as a sudden power failure. In these cases, follow the normal power down procedure. If not, the battery might reach its lifespan earlier than expected and become unusable within three years. When replacing the battery, follow the given procedure for disposing a used battery. 88 Replacement parts Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Data and power cables

The storage system supports a variety of data and power cables for specific hosting environments. □ Fibre Channel cables □ iSCSI cables □ Managing data cables □ AC power cables Data and power cables 89 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Fibre Channel cables

When constructing a system with the direct connection or Fibre Channel switch connection, consider the following: • If you connect a storage system to a FC host adapter through a switch, set Fabric = ON and set to Point-to-Point. • If you connect a storage system directly to FC host adapter with the following fabric topology: ○ For 2, 4 or 8 Gbps, set the storage port to Fabric = OFF and Connection Type FC-AL (Fibre Channel Arbitrated Loop). ○ For 16 or 32 Gbps, set the storage port to Fabric = OFF and Connection Type P-to-P (Point-to-Point). For the 8-Gbps Fibre Channel ports, the combinations between data- transfer speeds and connection types are as follows: Connection type Data transfer speeds for 8-Gbps ports 2 Gbps 4 Gbps 8 Gbps Auto FC-AL Available Available Available Available (default) P-to-P Available Available Available Available Fabric Available Available Available Available For the 16-Gbps Fibre Channel ports and for 16-Gbps SFP added to the 4- port FC 32-Gbps package, the combinations between data-transfer speeds and connection types are as follows: Connectio n type Data transfer speeds for 16-Gbps ports/SFPs 2 Gbps 4 Gbps 8 Gbps 16 Gbps 32 Gbps Auto FC-AL No available Available Available Not available Not available Available1 P-to-P No available Available Available Available Not available Available (default2) Fabric Available Available Available Available Not available Available Notes: 1. If this combination is specified, the maximum transfer speed automatically specified is 8 Gbps. 2. If this default value is set, Fabric is set to ON automatically. Note: To connect to the server by the 16-Gbps direct connection, the Fabric Emulation function of the Hitachi host adapter is required. 90 Data and power cables Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

For the direct connection using the Fabric Emulation function, set

the Fabric setting of the Fibre Channel port of the Storage System to ON. For the 32-Gbps SFP added to the 4-port FC 32-Gbps package, the combinations between data-transfer speeds and connection types are as follows: Connectio n type Data transfer speeds for 32-Gbps ports 2 Gbps 4 Gbps 8 Gbps 16 Gbps 32 Gbps Auto FC-AL No available No available Available Not available Not available Available1 P-to-P No available No available Available Available Available Available (default2) Fabric Available Available Available Available Available Available Notes: 1. If this combination is specified, the maximum transfer speed automatically specified is 8 Gbps. 2. If this default value is set, Fabric is set to ON automatically. Note: The five Hitachi FC HBAs also have an alternate option of Fabric Emulation. When the HBA is configured to use this mode, treat it as an attached switch and set the storage port to Fabric = On and Connection Type = P-to-P. • Due to high-speed serial data transfer is performed via Fibre Channel, use high-quality Fibre Channel cables that comply with the Fibre Channel-PH standard. Data and power cables 91 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Maximum length of cable

Multimode cable Single mode cable OM2 OM3 OM4 2 Gbps 984.25 ft (300 m) 1640.4 ft (500 m) — 3280.8 ft (10 km) 4 Gbps 493 ft (150 m) 1246.72 ft (380 m) 1312.3 ft (400 m) 8 Gbps 164.04 ft (50 m) 493 ft (150 m) 623.36 ft (190 m) 16 Gbps 114.8 ft (35 m) 328.08 ft (100 m) 410.1 ft (125 m) — 32 Gbps 65.62 ft (20 m) 229.7 ft (70 m) 328.08 ft (100 m) — The following table lists specifications of the Fibre Channel interface cable. Cable type Interface Cable mode name Nominal Cable Connector One side Other side LC-LC cable (shortwave) Optical Equivalent to DXLC-2P-PC- xxM-GC50, 125-2SR (OMx) 50, 125 μm, 62.5, 125 μm Multimode Wavelength: 850 nm LC connector LC connector 92 Data and power cables Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

The following figure shows the connector used for optical interfaces.

The following figure shows the type of optical connector that connects the storage system Fibre Channel ports. • LC connector type • Connector type: LC duplex receptacle connector • Interval: 6.25 mm flat type, two rows iSCSI cables When constructing an iSCSI system with a direct connection or switch connection, consider the following: Data and power cables 93 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Maximum length of cable

Multimode cable Single mode cable OM2 OM3 OM4 10 Gbps (FCoE) 269.02 ft (82 m) 984.25 ft (300 m) 1804.46 ft (550 m) — Cable specifications for iSCSI optical interface Cable type Interface Cable mode name Nominal Cable Connector One side Other side LC-LC cable Optical Equivalent to DXLC-2P-PC- xxM-GC50, 125-2SR (OMx) 50, 125 mm Multimode Wavelength: 850 nm LC connector LC connector The following figure shows the connector used for optical interfaces. The following figure shows the type of optical connector that connects the storage system optical iSCSI ports. • LC connector type • Connector type: LC duplex receptacle connector • Interval: 6.25 mm flat type, two rows 94 Data and power cables Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Cable specifications for 10 Gbps iSCSI copper interface

Cable type Maximum cable connection length Data transfer Transmission band Cable Connector Category 5e or 6a LAN cable 100 m 1 Gbps 1000BASE-T STP ( use an STP cable that suppresses radio noise) RJ-45 Category 6a LAN cable 50 m 10 Gbps 10GBASE-T STP ( use an STP cable that suppresses radio noise) RJ-45 The following figure shows a 10 Gbps iSCSI cable. Managing data cables Organize data cables to protect the integrity of your connections and allow proper airflow around your storage system. Observing bend radius values Never bend cables beyond their recommended bend radius. The following table provides general guidelines for minimum bend radius values, but you should consult the recommendation of your cable manufacturer. Cable type Minimum bend radius values Fibre Channel 1.73 inch (40 mm) iSCSI optical 1.73 inch (40 mm) Category 5 Ethernet Four times the outside diameter of the cable SAS 1.73 inch (40 mm) Protecting cables Damage to your Fibre Channel and Ethernet cables can affect the performance of your storage system. Observe the following guidelines to protect cables Data and power cables 95 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Keep cables away from sharp edges or metal corners.

• When bundling cables, do not pinch or constrict the cables. • Do not use zip ties to bundle cables. Instead, use Velcro hook-and-loop ties that do not have hard edges and which you can remove without cutting. • Never bundle network cables with power cables. If network and power cables are not bundled separately, electromagnetic interference (EMI) can affect your data stream. • If you run cables from overhead supports or from below a raised floor, include vertical distances when calculating necessary cable lengths. • If you use overhead cable supports: ○ Verify that your supports are anchored adequately to withstand the weight of bundled cables. ○ Gravity can stretch and damage cables over time. Therefore, do not allow cables to sag through gaps in your supports. ○ Place drop points in your supports that permit cables to reach racks without bending or pulling. Cabling full-width modules When cabling full-width modules, such as NAS modules as shown in the following figure, route the cables horizontally, so that they do not interfere when replacing a module. 96 Data and power cables Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Ensuring adequate airflow

Bundled cables can obstruct the movement of conditioned air around your storage system. • Secure cables away from fans. • Keep cables away from the intake holes at the front of the storage system. • Use flooring seals or grommets to keep conditioned air from escaping through cable holes. Preparing for future maintenance Design your cable infrastructure to accommodate future work on the storage system. Give thought to future tasks that will be performed on the storage system, such as locating specific pathways or connections, isolating a fault, or adding or removing components. • Purchase colored cables or apply colored tags. • Label both ends of every cable to denote the port to which it connects. AC power cables Utility AC power standards for connector types and voltage levels vary by country. Hitachi provides a variety of power cables that facilitate using storage systems around the world. Hitachi power cables meet the safety standards for the country for which they are intended. Power cable assemblies For information about racks and power distribution units (PDUs), refer to the Hitachi Universal V2 Rack Reference Guide. Hitachi power cables consist of three parts: • Plug: Male connector for insertion into the AC outlet providing power. The physical design and layout of the plug's contact meet a specific standard. • Cord: Main section of insulated wires of varying length, whose thickness is determined by its current rating. • Receptacle: Female connector to which the equipment attaches. The physical design and layout of the receptacle's contacts meet a specific standard. Common standards are the IEC C13 receptacle for loads up to 10 amperes (A) and the IEC C19 receptacle for loads up to 15 A. Data and power cables 97 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

CEE 7, 7

105 India 200-240 6, 16 IS-1293 South Africa 200-240 10, 16 SABS-164 11 Switzerland 200-240 10 SEV 1011 126 International 200-240 20 IEC 309 137 United Kingdom 200-240 13 BS-1363 International 200-240 20 IEC 309 148 International 200-240 30 IEC 309 Notes: 1. Also used for 200-240 VAC applications in Korea and Philippines. 2. Three-phase AC. 3. Also Malaysia and Ireland. 4. Also known as "Schuko" connector and used in Austria, Belgium, Finland, France, Germany, Greece, Hungary, Indonesia, Netherlands, Norway, Poland, Portugal, Russia, Spain, and Sweden. 98 Data and power cables Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Supersedes type BS 546.

6. 3-wire (two-phase and earth). Physical variations (connector size and color) indicate amperage rating. Used in Switzerland for a true 16 A application. 7. 4-wire (three-phase and earth). Physical variations (connector size and color) indicate amperage rating. 8. 5-wire (three-phase, earth and neutral). Physical variations (connector size and color) indicate amperage rating. AC connections The following table shows and describes the types of AC connections on your storage system. Description Receptacle (male end) Input rating Reference standards NEMA 5-15P 100V-120V (standard attachment) 1 ANSI C73.11 2 NEMA 5-15P 3 IEC 83 NEMA L6-20P 200V-240V 1 ANSI C73.11 2 NEMA 6-15P 3 IEC 83 CEE 7/7 200V-240V 4 CEE (7) II, IV, VII 3 IEC 83 BS-1363 200V-240V 5 BS 1365 3IEC 83 Data and power cables 99 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Receptacle (male end)

Input rating Reference standards AS-3112 200V-240V 6 AS C112 Power cable usage guidelines Hitachi storage systems are intended for rack installation and ship with power cords. Installation and service requirements may require additional cords and cables to be ordered. The type of power cable required by a given installation is determined primarily by the: • Type of AC line feed provided by the facility. • Type of AC source (wall outlet or modular and monitored PDU) to be used. • Serviceability of components to be connected. Storage systems require a country-specific power cable for direct connection to a facility AC feed. Storage systems are designed to allow replacement of hot-pluggable components without removing the chassis from the rack. As a result, power cables can be short because cable movement is of minimal consideration. Three-phase power considerations for racks Increasing power requirements for racks are making the use of three-phase power at the rack level compelling. • With single-phase power, at any given time the voltage across the hot and neutral conductors can be anywhere between its peak (maximum) and zero. Electrical conductors must be large to meet high amperage requirements. • Three-phase power uses three cycles that are 120 degrees out of phase, which never allows the voltage to drop to zero. The more consistent voltage derived from the three hot conductors results in smoother current flow and allows small-gauge conductors to be used to distribute the same amount of AC power. As a result, the load balancing and increased power 100 Data and power cables Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide

Other Storage Manuals