Johnson & Starley Reno HE30C User Instructions
Read Online
Read the Johnson & Starley Reno HE30C User Instructions online using the built-in PDF viewer.
Text of the manual
High Efficiency Combination Boiler
Johnson & Starley
www.johnsonandstarley.co.uk
Model: HE30C
GC No: 47-416-01
User’s Instructions
Tel: 01604 762 881
Publication ZZ1184/1
Product Identification No: 87B 074
Symbols on the user display:
82
12
1.0
PRE-
HEAT
Temperature of the central
heating flow.
Pump is running.
Pre-heat is selected.
Anti-cycle feature is in operation
Outside temperature, when OTC
sensor is connected.
Pressure in heating circuit
Fan is running
oC
oC
bar
65
Temperature of the domestic
hot water
Ignitor is sparking
Summer mode
Flame modulation
Opentherm boiler management
system is connected
Error code
oC
ER88
:
RESET
Space for optional programmer
Power On/Off switch
Domestic hot water control (P2)
Reset button
Central Heating water
temperature control (P1)
Preheat button
View of user control panel
Control PPanel
The flip door at the bottom of the boiler is held in the closed posision by a concealed latch that has a push and
release mechanism and is located on the upper edge of the door in the centre. To gain access to the control panel,
apply light pressure on the upper edge of the flip door at the centre, the latch will then release allowing the door to
drop into the open position.
To close the flip door, swing it into the closed position and apply light pressure to the upper edge in the centre of the
door and the latch mechanism will lock the door into place.
If turning on the boiler for the first time
carry out the following steps:
• Check that the electrical supply
to the boiler is ON at the
external isolator.
• Ensure all hot taps are closed.
• Set any remote controls as
required.
• Turn the CH and DHW controls to
the minimum setting. Switch on
the appliance at the on/off switch
on the control panel. The boiler will
then be in the STANDBY mode.
• Check the heating system pres-
sure displayed in the RH lower
corner of the display. This should
read at least 1.0 bar. A sealed
pressurised system must be filled
by a competent person.
Only operate the boiler when you are
sure that the system has been filled
and pressurised. If you are in any
doubt about the boiler being filled
with water contact your installer.
Operation oof CCentral
Heating
In order to turn on the central heating
and adjust the temperature, turn the
control knob P1 to the desired setting
between off and max 82°C.
When the control knob is turned the
central heating water temperature will
flash and indicate the new temperature
setting.
After a delay of 5 seconds the display
will revert to a steady display of actual
central heating water temperature.
This will disappear if there is no
central heating demand.
During a central heating demand the
radiator symbol and the central heating
water temperature will be illuminated
on the display.
If central heating is not required for
any extended period turn the control
knob P1 fully anti-clockwise to the off
position. In this position the “heating
off “ symbol will be displayed, the
domestic hot water and frost protec-
tion will still be active. This is also
the “summer mode”.
Operation oof DDomestic
Hot W
Water
The domestic hot water temperature
is adjustable between 30°C and 65°C
by the control knob P2.
When the control knob is turned the
DHW water temperature will flash
and indicate the new temperature
setting.
After a delay of 5 seconds the dis-
play will revert to a steady display of
actual DHW temperature. This will
disappear if there is no DHW
demand.
During a DHW demand, the tap
symbol and the DHW temperature
will be illuminated on the display.
Pre-heat BButton
With the pre-heat button selected the
boiler is maintained in a hot condition
to enable a fast response to any DHW
demand. When selected, PRE-HEAT
will be illuminated on the display.
If required this can be selected for
all year round use, but will be of
maximum benefit in the summer
months, or when there is little or no
demand for central heating, in
which case the boiler would become
cold without the pre-heat button
selected.
The pre-heat function has a built-in
intelligent function that will turn itself
off if there is no DHW demand for a
24 hour period. If previously selected,
once DHW water has been drawn off,
the function will automatically re-
enable.
Reset BButton
Should a fault occur this button can
be pressed to reset the controls and
initiate a new start up sequence.
Should the flame signal be lost 5
times in any 4 minute period then
the boiler will lockout and an error
code will be displayed in the centre
of the display. Pressing the reset will
enable the boiler to relight.
If the fault recurs, turn off the boiler
and consult a CORGI registered
installer.
Boiler ooverheat
In the event of the boiler overheating
the boiler will lockout and an error
code will be displayed in the centre
of the display. Pressing the reset will
enable the boiler to relight.
If the fault recurs, turn off the boiler
and consult a CORGI registered
installer.
Water SSystem PPressure
The water system pressure is
shown in the bottom right hand of
the display.
If the pressure drops below 1.0 bar
it will begin to flash indicating the
system needs to be topped up by a
competent person.
If the pressure continues to drop and
reaches 0.6 bar, an error code will
appear in the centre of the display
and all heat demands will be
blocked. This may indicate a leak
and the system should be checked
before being re-pressurised.
Condensate DDrain
The condensate drain must not be
modified or blocked.
Blockage of the condensate drain
caused by debris or freezing, can
cause the boiler to lockout.
If freezing is suspected and the pipe
run is accessible, then an attempt to
free the obstruction by pouring hot
water on to the pipe may be made.
If this fails to remedy the problem,
the assistance of a CORGI registered
installer should be sought.
Service aand M
Maintenance
It is recommended that a full mainte-
nance check be carried out annually on
the appliance. It is also recommended
to take out a further service agreement
on the expiry of the guarantee period.
You can obtain further information
on this from your gas supplier.
The appliance should be checked
/servicedby a CORGI registered
installer.
If you require service on your appliance
please contact your local installer or
gas supplier.
On completion of the service the
installer should fill in the service sec-
tion at the rear of the BENCHMARK
log book. All installers registered with
CORGI carry an identification card.
This card will have an ID number
which should be recorded in your
logbook.
If you have any queries regarding
your installer you can contact CORGI
by telephone on 01256 372400.
Escape oof GGas
Should a gas leak be suspected
contact your gas supplier with out
delay.
Do not search for leak with a naked
flame.
Cleaning tthe AAppliance
The appliance casing should only be
cleaned with a damp cloth then
dried.
Do not use abrasive or solvent
cleaners.
Error CCodes
For any other error codes that you
may encounter on your boiler, please
refer to your Installation &
Maintenance Instructions or contact
your local CORGI registered installer.
1.0bar
bar
0.9
ER:26
RESET
ER:37
RESET
ER:??
RESET
ER:03
RESET
Analogue ttime ccontrol ((if ffitted)
Setting the time
• Rotate the dial clockwise, by hand, until the indicator
arrow is pointing to the current time.
Note the time is set in 24 hour format.
Setting the central heating on and off times
• Select the on times by pushing the black tappets to
the outside.
• Select the off times by pushing the black tappets to
the inside
Overriding the clock
The clock has a manual on off switch which operates as
follows
1
Heating on continuously
Heating on timed
0
Heating off
Indicator
Arrow
1
0
Black Tappets
Digital PProgrammer ((if ffitted)
Button Description
Time/Automatic Run mode selection
Prog
Programme selection
Res.
Reset clears all settings
ON/OFF selection in Prog mode,
Manual override selector in run mode
+/-1h
Summer/Winter time settings
h
Sets the hour
m
Sets the minute
Day
Sets days
LCD DDisplay
The LCD display incorporates a number of different elements to display vari-
ous data and information
Programmes
The Digital Programmer will accept up to 20 events
Each event consists of:
• An ON or OFF command
• Time of Day (hour and minute)
• Single day or multiple days
An event is required for each ON and OFF.
NOTE: MULTIPLE ON OR OFF EVENTS MAY BE PRO-
GRAMMED, SEE EXAMPLE.
BEFORE PROCEEDING WITH SETTING THE TIME AND
PROGRAMMING THE UNIT, PRESS THE RESET KEY TO
CLEAR ALL DATA FROM THE MEMORY.
Run mode:
Off
Continous off
On
Continous on
1 2 3 4 5 6 7
+1h
AM
8
88
8 :
Days of week
Time of
day
Manual
override on
Press and hold the
key during the following:
(If British summer time is in effect, press +/- 1h first)
• Press h to advance the current hour (While holding
down the key)
• Press m to advance to the current minute (While hold-
ing down the key)
• Press DAY repeatedly to advance to current day (While
holding down the key)
Selecting AAM/PM oor 224 hhour cclock
After pressing reset the display may show AM, numbered
days will be flashing on and off.
If the display does not show AM. It is in 24 hour mode,
press and hold the h key and press the +/-1h key once.
AM will appear in the display
If display is in AM/PM mode and 24 hour time mode is
desired, press and hold the h key, press the +/- key once
Setting tthe TTime
If the h and m keys are held down longer than 2 sec-
onds, the numbers will advance rapidly.
Day KKey SSelections
Press Day Key
Display shows
Days
0 times
1234567
Every day
1 time
123456
mon-sat
2 times
12345
Mon-fri
3 times
67
sat & sun
4 times
1
Monday
5 times
2
Tuesday
6 times
3
Wednesday
7 times
4
Thursday
8 times
5
Friday
9 times
6
Saturday
10 times
7
Sunday
Note: if the days are flashing, it indicates the day of the
week was not set when setting the time. The timer cannot
be programmed unless the day of the week is entered.
Manual GGMT/BST ttime cchangeover
Each year, in the spring press +/- 1h to advance the time
an hour. In the Autumn press +/- 1h to set back an hour.
Programming 224 hh oor 77 dday SSchedules
It may be helpful to write out the programme schedules
before beginning.
Example
Event 1: On at 7.00AM Monday through to Saturday
Event 2: Off at 5.00PM Monday through to Friday
Event 1: Off at 7.00PM Saturday
Three events need to be entered.
Event 1 (ON at 7:00AM Monday through Saturday)
Press
key once. ON symbol
appears
Press h key to 07AM
Press m key once to 00
Press Day key once 123456 is displayed
Press Prog key to enter
Event 2 (Off at 5.00PM Monday through to Friday)
Press
key twice. Off symbol
appears
Press h key to 05PM
Press m key once to 00
Press Day key twice 12345 is displayed
Press Prog key to enter
Event 3 (Off at 7.00PM Saturday)
Press
key twice. ON symbol
appears
Press h key to 07PM
press m key once to 00
Press Day key 9 times 6 is displayed
Press Prog key to enter
Press
key to enter run mode
IF 24 HOUR TIME CONTROL (SAME SCHEDULE EVERY
DAY OF THE WEEK) IS DESIRED IGNORE Day KEY.
1 2 3 4 5 6 7
AM
- --
- :
Event RReview
To review the programs at any time, press Prog key.
Events will appear in the order they were entered with
repeated presses of the Prog key. After all events have
been reviewed the display will go blank in order to allow
you to enter another event. Another press of the Prog key
will display the number of free events spaces.
Manual OOverride
While in the run mode, pressing the
key will reverse
the current mode i.e on to off or off to on.
1 2 3 4 5 6 7
+1h
AM
8
88
8 :
Time of
day
Johnson & Starley
www.johnsonandstarley.co.uk
Tel: 01604 762 881
Continuous ooperation
While in the run mode, press the
key twice to turn
the output to permanently on. The
symbol appears in
the display.
To revert back to timed operation press the
until the
symbol appears in the display.
Changing aan EEvent
Select the event to be changed with the Prog key. A new
set of days may be selected with Day key just as in initial
programming.
Hours and minutes can be changed with the h and m
keys
Press the Prog key to store the new programme.
Troubleshooting
Problem: days are flashing and pressing any key does nothing BUT
key turns output ON and OFF.
Solution: Time of Day and DAY of Week have not been set. This may occur if the power has been off to boiler for longer
than 3 days.
Problem: Time of day was set while holding the
key down but the days are still flashing.
Solution: Current day of the week has not been set.
Problem: It is 10AM and an ON event for 8AM was entered but the output symbol is not ON. Display shows the
and
the
symbols
Solution: After programming the timer does not look back and will not take place until the event recurs at 8AM tomorrow.
In order to turn the boiler ON use the manual override.