ENTRY DEVIATION MENU 96

Enter 96-(o). Enter 9 - 6 followed by the key corresponding to the Option Number required from the table below: Enter 0 Disabled (Default) Enter 1 Enabled PRINT EVENT LOG MENU 97 Enter 97-(o). Enter 9 - 7 followed by the key corresponding to the Option Number required from the table below: Enter 0 Disabled (Default) Enter 1 Print log The full 250 Event time and date stamped Log can be printed in full by a serial printer connected to the AUX supply and loudspeaker terminal via an adapter (Part No. 2011-096). Connect to the panel as follows. The data format is ...

DOWNLOADER - FIRST CONNECTION

To make a first contact from the downloader to the panel. The panel requires the following options programmed before a connection from the downloader can be made. The panel must be in “Day Mode” to enable a connection. At the Panel 1. Enter engineer mode by entering 9090 # *, The power LED will flash. 2. If the control panel programming has not been completed, restore the panel defaults by entering 981 followed by 981 again. 3. Enter the # and * keys to exit programming mode. At the Downloader 1. Create a new site (menu “Site” then “New Site”) p ...

BELL OUTPUT POLARITY MENU 56

Enter 56-(o). Enter 5 - 6 followed by the key corresponding to the Option Number required from the table below: Enter 0 Negative applied (Default) Enter 1 Negative removed ALARM OUTPUT POLARITY MENU 57 Enter 57-(o). Enter 5 - 7 followed by the key corresponding to the Option Number required from the table below: Enter 0 Negative applied (Default) Enter 1 Negative removed TAMPER ALARM RESET MENU 58 Enter 58-(o). Enter 5 - 8 followed by the key corresponding to the Option Number required from the table below: Enter 0 Customer (Default) Enter 1 Engineer Enter ...

DOWNLOADER - FIRST CONNECTION

To make a first contact from the downloader to the panel. The panel requires the following options programmed before a connection from the downloader can be made. The panel must be in “Day Mode” to enable a connection. At the Panel 1. Enter engineer mode by entering 9090 # *, The power LED will flash. 2. If the control panel programming has not been completed, restore the panel defaults by entering 981 followed by 981 again. 3. Enter the # and * keys to exit programming mode. At the Downloader 1. Create a new site (menu “Site” then “New Site”) p ...

COMMUNICATE LOW BATTERY & MAINS LOSS MENU 88

Enter 88-(o). Enter 8 - 8 followed by the key corresponding to the Option Number required from the table below: Enter 0 No (Default) Enter 1 Yes COMMUNICATE PERIODIC TEST REPORT MENU 89 Enter 89-(o). Enter 8 - 9 followed by the key corresponding to the Option Number required from the table below: Enter 0 No (Default) Enter 1 Every 24 hrs Enter 2 Every 7 days Enter 3 Every 31 days COMMUNICATE ISOLATE MENU 91 Enter 91-(o). Enter 9 - 1 followed by the key corresponding to the Option Number required from the table below: Enter 0 No (Default) ...

COMMUNICATE LOW BATTERY & MAINS LOSS MENU 88

Enter 88-(o). Enter 8 - 8 followed by the key corresponding to the Option Number required from the table below: Enter 0 No (Default) Enter 1 Yes COMMUNICATE PERIODIC TEST REPORT MENU 89 Enter 89-(o). Enter 8 - 9 followed by the key corresponding to the Option Number required from the table below: Enter 0 No (Default) Enter 1 Every 24 hrs Enter 2 Every 7 days Enter 3 Every 31 days COMMUNICATE ISOLATE MENU 91 Enter 91-(o). Enter 9 - 1 followed by the key corresponding to the Option Number required from the table below: Enter 0 No (Default) ...

BELL CUT-OFF TIME MENU 43

Enter 43-(o). Enter 4 - 3 followed by the key corresponding to the Option Number required from the table below: Enter 1 1 Minute Enter 2 2 Minutes Enter 3 3 Minutes Enter 4 4 Minutes Enter 5 5 Minutes Enter 6 10 Minutes Enter 7 15 Minutes Enter 8 20 Minutes (Default) Enter 9 30 Minutes PART SET EXIT WARNING SOUNDER MENU 44 Enter 44-(o). Enter 4 - 4 followed by the key corresponding to the Option Number required from the table below: Enter 0 Fault & comfort tones only (Default) Enter 1 Keypad buzzer only Enter 2 Keypad buzzer and sounder Note. Night set will a ...

LINE FAULT INHIBIT SETTING MENU 73

Enter 73-(o). Enter 7 - 3 followed by the key corresponding to the Option Number required from the table below: Enter 0 No (Default) Enter 1 Yes, inhibit setting with phone line fault BELL DELAY MENU 74 Enter 74-(o). Enter 7 - 4 followed by the key corresponding to the Option Number required from the table below: Enter 0 No (Default) Enter 1 Yes, 10 minute bell/sounder delay on alarm PUSH TO SET MENU 75 Enter 75-(o). Enter 7 - 5 followed by the key corresponding to the Option Number required from the table below: Enter 0 No timed or contact set ( ...

IntelliSense SECURIT 900C user guide recommended for: GP-4100 series, SR-10K, SECURIT 800L, BTP-2002NP, LS-GSM-006.

⚠️ Download Safety

The Control Panel Installation manual (32 pages) is completely safe to download (last scan date: 17/05/2026).