Johnson & Starley HE16S User Instructions
Read Online
Read the Johnson & Starley HE16S User Instructions online using the built-in PDF viewer.
Text of the manual
Johnson & Starley
R E L I A B I L I T Y Y O U C A N T R U S T
Publication No. ZZ 1187-4 March 2008
Product Identification No: 87B 074
USERS INSTRUCTIONS
Natural Gas G20:
Reno HE16S - GC No: 41-416-05
Reno HE25S - GC No: 41-416-02
Reno HE31S - GC No. 41-416-04
Propane G31 Variant:
Reno HE16SP - GC No: 41-416-09
Reno HE25SP - GC No: 41-416-12
Reno HE31SP - GC No. 41-416-08
SYSTEM
SERIES
High Efficiency
System
Boilers
www.johnsonandstarley.co.uk
BS EN ISO 9001 : 2000
www.energysavingtrust.org.uk
The Johnson & Starley Reno range has an
energy rating A on a scale of A to G.
For more information see
www.boilers.org.uk
This is a certification mark.
Telephone: 01604 762881
82˚C
12˚C
1.0 bar
1. SYMBOLS ON THE USER PANEL
Temperature of the central heating flow.
Fan is running.
Pump is running.
Ignitor is sparking.
Pressure in heating circuit.
Central heating off mode.
Anti-cycle feature is in operation.
Flame modulation.
Outside temperature, when an OTC sensor is connected.
Opentherm boiler management system is connected.
Error code.
USER CONTROL PANEL
Central Heating Water
Temperature Control (P1)
Power ON/OFF Switch
Reset Button
2.
CONTROL PANEL
The flip door at the bottom of the boiler is held in the closed position
by a concealed latch that has a push and release mechanism and is
located on the upper edge of the door in the centre. To gain access
to the control panel, take hold of the side of the panel at the corners
and pull panel towards you, allowing the door to drop into the open
position.
To close the flip door, lift up the panel and and push shut until it
clicks into place.
Telephone: 01604 762881
3.
INITIAL LIGHTING
If turning on the boiler for the first time carry out the following
steps:
Check that the electrical supply to the boiler is ON at the
external isolator.
Ensure all hot taps are closed.
Set any remote controls as required.
Turn the CH to the minimum setting. Switch on the appliance
at the on/off switch on the control panel. The boiler will then
be in the STANDBY mode.
Check the heating system pressure displayed in the RH
lower corner of the display. This should read at least 1.0
bar. A sealed pressurised system must be filled by a
competent person.
Only operate the boiler when you are sure that the system has
been filled and pressurised. If you are in any doubt about the
boiler being filled with water contact your installer.
4.
OPERATION OF THE BOILER
In order to turn on the central heating and adjust the temperature,
turn the control knob P1 to the desired setting between off and
max 82°C.
When the control knob is turned the central heating water
temperature will flash and indicate the new temperature setting.
After a delay of 5 seconds the display will revert to a steady display
of actual central heating water temperature. This will disappear if
there is no central heating demand.
During a central heating demand the radiator symbol and the
central heating water temperature will be illuminated on the
display.
If central heating is not required for any extended period turn
the control knob P1 fully anti-clockwise to the off position. In this
position the frost protection will still be active.
5.
RESET BUTTON
Should a fault occur this button can be pressed to reset the
controls and initiate a new start up sequence.
6.
FLAME LOSS
Should the flame signal be lost 5 times in any 4 minute period
then the boiler will lockout and an error code will be displayed in
the centre of the display. Pressing the reset will enable the boiler
to relight.
If the fault recurs, turn off the boiler and consult a CORGI
registered installer.
7.
BOILER OVERHEATING
In the event of the boiler overheating the boiler will lockout and an
error code will be displayed in the centre of the display. Pressing
the reset will enable the boiler to relight.
If the fault recurs, turn off the boiler and consult a CORGI
registered installer.
1.0 bar
82˚C
82˚C
ER:26
ER:03
WATER SYSTEM PRESSURE
The water system pressure is shown in the bottom right hand of
the display.
If the pressure drops below 1.0 bar it will begin to flash indicating
the system needs to be topped up by a competent person.
If the pressure continues to drop and reaches 0.6 bar, an
error code will appear in the centre of the display and all heat
demands will be blocked. This may indicate a leak and the
system should be checked before being re-pressurised.
9.
CONDENSATE DRAIN
The condensate drain must not be modified or blocked.
Blockage of the condensate drain caused by debris or freezing,
can cause the boiler to lockout.
If freezing is suspected and the pipe run is accessible, then
an attempt to free the obstruction by pouring hot water on to
the pipe may be made. If this fails to remedy the problem, the
assistance of a CORGI registered installer should be sought.
10. SERVICE & MAINTENANCE
It is recommended that a full maintenance check be carried out
annually on the appliance. It is also recommended to take out a
further service agreement on the expiry of the guarantee period.
You can obtain further information on this from your gas supplier.
The appliance should be checked /serviced by a CORGI
registered installer.
If you require service on your appliance please contact your local
installer or gas supplier.
On completion of the service the installer should fill in the service
section at the rear of the BENCHMARK log book. All installers
registered with CORGI carry an identification card. This card will
have an ID number which should be recorded in your logbook.
If you have any queries regarding your installer you can contact
CORGI by telephone on 01256 372400.
11. ESCAPE OF GAS
Should a gas leak be suspected contact your gas supplier with
out delay.
Do not search for leak with a naked flame.
12. CLEANING THE APPLIANCE
The appliance casing should only be cleaned with a damp cloth
then dried.
Do not use abrasive or solvent cleaners.
13. ERROR CODES
For any other error codes that you may encounter on your boiler,
please refer to your Installation & Maintenance Instructions or
contact your local CORGI registered installer.
1.0 bar
0.9 bar
ER:37
ER:??
Johnson & Starley
R E L I A B I L I T Y Y O U C A N T R U S T
www.johnsonandstarley.co.uk
RENO BOILER
RANGE
ECONOMAIRE WARM AIR HEATERS
HI-SPEC WARM AIR HEATERS
HEAT RECOVERY
HOME ‘N’ DRY
VENTILATION
DRYFLOW
RENOXTRA
CENTRAL EXTRACT
VENTILATION SYSTEM
DRAVO
Johnson & Starley are the leading UK &
European manufacturers of a complete range
of Domestic Warm Air Heaters.
All the heaters suit both Replacement and
Upgrade needs and are compliant with the
new (2006) amendments to Part L of the
Building Regulations.
HOME COMFORT SOLUTIONS
Company Details
Website Address
www.johnsonandstarley.co.uk
Email
[email protected]
[email protected]
Telephone Number
01604 762881 (Main switchboard)
Fax Number
01604 767408
Spares
Telephone
01604 707012
Fax
01604 762884
Sales
Telephone
01604 707012
Fax
01604 764879
Service
Telephone
01604 707011
Fax
01604 707017
Warm Air Upgrade Enquiry Service
Telephone
01604 707026
Fax
01604 707017
COMMERCIAL & INDUSTRIAL
H&V SOLUTIONS
Company Details
Johnson & Starley
Dravo Division Industrial H&V
Website Address
www.dravo.co.uk
Email
[email protected]
T elephone Number
01604 707022
Fax Number
01604 706467