READ AND SAVE THESE INSTRUCTIONS Owner’s Manual Model 8570 Includes Operating Instructions and Warranty Information

About half of all energy used by households goes to heating and cooling the

home. By selecting a programmable Aprilaire® Electronic Thermostat, you have made a significant step toward conserving energy usage and costs, while improving your indoor comfort. In fact, the Aprilaire® Model 8570 Premium Programmable Thermostat has earned the “ENERGYSTAR®” designation of the U.S. Environmental Protection Agency (EPA). This means that your Aprilaire Thermostat is a highly efficient, cutting edge product that is good for the environment. It saves energy and costs less to operate than similar products that do not qualify for the ENERGYSTAR label. ENERGYSTAR products help you differentiate between standard efficiency and high efficiency products. By using ENERGYSTAR products, you are helping to prevent air pollution while saving money on your utility bills. According to the EPA, by programming your thermostat and taking advantage of the times that a building is unoccupied or the occupants are asleep, an ENERGYSTAR thermostat can reduce heating and cooling bills by as much as $150. The Aprilaire Thermostat has programmable capabilities that allow you full flexibility to set your heating and cooling systems to meet your comfort and energy needs. As an ENERGYSTAR partner, Aprilaire has determined that this product meets the ENERGYSTAR guidelines for energy efficiency. TABLE OF CONTENTS PAGE ENERGYSTAR® Program Information . . . . . . . . . . . . . . . . . . 1 Getting Familiar with your Aprilaire® 8570 Thermostat. . . . . . . . . . . . . . . . . . . . . . . 2 Operating Your Thermostat . . . . . . . . . . . . . . . . . . . . . . . 4 Setting the Mode of Operation – Heat, Cool, etc. . . . . . 5 Temporarily Raising and Lowering the Temperature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Fan Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Setting the Date and Time . . . . . . . . . . . . . . . . . . . . . . . 9 PAGE Programming your Thermostat . . . . . . . . . . . . . . . . . . . 10 Holding Temperature – Holiday and Permanent . . . . . 12 Settings Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Info Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Viewing Other Thermostats on the System . . . . . . . . . 18 In Case of Power Failure . . . . . . . . . . . . . . . . . . . . . . . . 19 Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Event Desired Temperature Setting Daily Time Schedule Wake Heat = 70° Cool = 78° 6:00 am Leave Heat = 62° Cool = 85° 8:00 am Return Heat = 70° Cool = 78° 5:00 pm Sleep Heat = 62° Cool = 82° 10:00 pm ENERGYSTAR® PROGRAM INFORMATION Program your thermostat to save energy while you’re asleep or away. Saving energy helps prevent global warming LEARN MORE AT energystar.gov

FIGURE 1 – GETTING FAMILIAR WITH YOUR APRILAIRE® 8570 THERMOSTAT

EQUIPMENT STATUS OUTDOOR TEMPERATURE ROOM TEMPERATURE MESSAGE CENTER SETPOINTS UP/DOWN BUTTONS MULTI-FUNCTION BUTTONS MESSAGE CENTER Normally this is where you will find the current date and time and the name of the current event if running the temperature program. If the thermostat is in a Hold State, the thermostat will display when the Hold State is scheduled to end. The area is also used to give information on when you should replace your air filter or UV lamp, when you should service your humidifier and general HVAC equipment. When installed with an Aprilaire® Automatic Digital Humidifier Control (Model 58) and Humidifier, the message center will also inform you if the humidifier is operating. EQUIPMENT STATUS In this area of the display, the thermostat will show the equipment’s mode and whether the equipment is active. A typical message in this area would be HEAT MODE when the equipment is not running and HEATING when the equipment is active. OUTDOOR TEMPERATURE The thermostat has terminals that can be hooked up to an outdoor temperature sensor. If this is installed, outdoor temperature will be displayed in this area of the screen. When installed with an Aprilaire® Automatic Digital Humidifie Control (Model 58) or an Aprilaire® Model 6504 Intelligent Zon Comfort System, this information is communicated to the thermo so there is no need for the extra outdoor temperature sensor. ROOM TEMPERATURE The large temperature on the screen is the room temperature. The scale can be changed from Fahrenheit to Celsius if desired SETPOINTS The setpoints are the temperature(s) to which the thermostat is controlling. MULTI-FUNCTION BUTTONS The multi-function buttons are used throughout the thermostat menu system and have many functions. The description on the screen directly above the button is what that button is used fo that particular screen. In Figure 1, the left button would be us for INFO and the right button would be used for MENU. UP/DOWN BUTTONS These buttons are used to raise and lower temperature and to navigate through the thermostat’s menus. 2

OPERATING YOUR THERMOSTAT

Backlight Operation When any button is pressed, the backlighting will illuminate. Once the backlight is on, subsequent button presses will perform their respective tasks. Using the Up & Down Buttons and Multi-Function Buttons on the Thermostat This thermostat uses a menu driven display and four (4) buttons. The Up and Down buttons are generally used to move between selections in the menu and to raise and lower different parameters such as temperature, days, minutes etc., depending on which screen you are viewing. The multi-function buttons have a variety of uses. The portion of screen directly above these buttons will display the button’s function. For instance, when the main screen is being viewed, the buttons are titled INFO and MENU from left to right respectively. To access the menu of the thermostat, press the right multi-function button. Notes on Temperature Adjustments The Cool setting must always be 2° or 5° (F or C) higher than the Heat setting. The value (2° or 5°) is selectable. The thermostat will automatically change the temperature setting not being adjusted to maintain this difference, even if both settings are not shown on the display. 4 1. Setting the Mode of Operation – Heat, Cool, etc. The thermostat can be set to OFF, HEAT, COOL, AUTO and EMERGENCY HEAT (EMERGENCY HEAT for heat pumps only) modes. To set the mode, press the MENU button on the main screen. Once in the Main Menu screen, use the down button to move the highlighted text to the desired mode, then press SELECT. Example: Placing thermostat in HEAT MODE. 9/11/05 5:15PM OUTDOOR OFF MODE 45° FAN AUTO INFO MENU 72° MAIN MENU SET MODE: OFF AUTO COOL HEAT SET FAN: AUTO ON MORE EXIT SELECT HEAT 9/11/05 5:15PM OUTDOOR HEAT MODE 45° FAN AUTO SETPOINT HEAT 74 INFO MENU 72° CAUTION: Do not set to OFF mode during periods when freezing temperatures could occur. NOTE: When installed with an Aprilaire® Model 6504 you will be given the option to CHANGE ALL THERMOSTATS. If you select YES to this, the mode setting will be set to whatever you have selected for all the thermostats on the system.

3. Fan Operation

The thermostat allows you to operate the fan manually or it can change the fan setting for you automatically with each programming event. For manual operation, from the MAIN MENU simply select SET FAN: ON to run the fan all the time, or SET FAN: AUTO to run the fan only during heating and cooling calls. NOTE: When installed with an Aprilaire® Model 6504 you will be given the option to CHANGE ALL THERMOSTATS. If you select YES to this, the fan setting will be set to whatever you have selected for all the thermostats on the system. For automatic operation, select PROGRAMMED FAN from the MAIN MENU, and then select ENABLE. In the Fan Status setting screen, you set the fan to be either ON or AUTO during each of the programming events (see page 10 for details on the programming events). Use the and buttons to move to the Fan Status you wish to change, and use the or to change to ON or AUTO. Once you are done, use the button to highlight DONE and then press SAVE. 2. Temporarily Raising and Lowering the Temperature You can raise or lower the temperature by simply pressing the Up/Down buttons, then SAVE. Example: The Setpoint is at 68°, you want the temperature to be 72°. If you are in AUTO Mode, both heat and cool settings will be displayed on the hold screen. First you can change the Heat setting, then the Cool setting. If you do not want to change one of these settings, simply select the or to go to the next setting or BACK to go to the main screen. If you were running the temperature program when you made the change, the message center displays when the thermostat will return to programmed operation. Press the RESUME PROG. button to return to programmed operation at any time. 9/11/05 5:15PM OUTDOOR OFF MODE 45° FAN AUTO INFO MENU 72° 9/11/05 5:15PM OUTDOOR OFF MODE 45° FAN ON INFO MENU 72° MAIN MENU SET MODE: OFF AUTO COOL HEAT SET FAN: AUTO ON MORE EXIT SELECT ON HOLD THIS TEMPERATURE UNTIL 10:00PM HEAT COOL BACK71° HEAT 76° 8/27/05 5:15PM OUTDOOR AUTO MODE 81° FAN AUTO SETPOINT HEAT 71 COOL 76 INFO MENU 76° HOLD TIL 10:00PM OUTDOOR COOLING 81° FAN AUTO SETPOINT HEAT 71 RESUME COOL 74 PROG. MENU 76° HOLD THIS TEMPERATURE UNTIL 10:00PM HEAT COOL SAVE 71° COOL 74° 3/11/05 5:15PM OUTDOOR HEAT MODE 20° FAN AUTO SETPOINT HEAT 68 INFO MENU 68° HOLD TIL 10:00PM OUTDOOR HEAT MODE 20° FAN AUTO SETPOINT HEAT 72 RESUME PROG. MENU 68° HOLD THIS TEMPERATURE UNTIL 10:00PM HEAT BACK SAVE 72° HEAT MAIN MENU MORE HOLD PROGRAM PROGRAMMED FAN SETTINGS SET DATE AND TIME EXIT SELECT PROGRAMMED FAN DISABLE ENABLE BACK SELECT PROGRAMMED FAN FAN STATUS WAKE AUTO LEAVE AUTO RETURN AUTO SLEEP AUTO DONE WAKE AUTO PROGRAMMED FAN FAN STATUS WAKE ON LEAVE AUTO RETURN ON SLEEP ON DONE CANCEL SAVE DONE PROGRAMMED FAN ENABLE

When operating Programmed Fan, you can temporarily change the fan status by selecting SET FAN: ON or AUTO

from the MAIN MENU, but it will return to the program at the start of the next programming event. To permanently discontinue automatic fan operation, select DISABLE from the PROGRAMMED FAN menu. 4. Setting the Date and Time In the SET DATE AND TIME menu, you can set the correct date and time and activate or deactivate the automatic Daylight Savings Time Adjustment. 4.1 Automatic Daylight Savings Adjustment When ‘AUTO DAYLIGHT SAVINGS’ is selected, you have the option of selecting ‘ON’ or ‘OFF’. When this feature is set to ON, the clock will automatically compensate for Daylight Savings Time. 4.2 Date & Time Screens When SET DATE and TIME is selected from the Menu, you will be taken through a series of steps to set the month, day, year, hour and minute. Use the Up/Down buttons to adjust the values. Use the or to move from month, to day, year, etc. Then select SAVE when done. NOTE: When installed with an Aprilaire® Model 6504 you will be given the option to CHANGE ALL THERMOSTATS. If you select YES to this, the time setting will be set on all the thermostats on the system. MAIN MENU MORE HOLD PROGRAM PROGRAMMED FAN SETTINGS SET DATE AND TIME EXIT SELECT SET DATE AND TIME SET DATE AND TIME AUTO DAYLIGHT SAVING BACK SELECT SET DATE AND TIME AUTO DAYLIGHT SAVING AUTO DAYLIGHT SAVING ON OFF BACK SELECT ON DONE SET DATE AND TIME SET MINUTES 11/ 27/05 1: PM SAVE 00 SET MINUTES SET DATE AND TIME SET HOUR 11/27/05 :00 SET HOUR SET DATE AND TIME SET DAY 11/ /05 12:00PM SET DAY 01 SET DATE AND TIME SET MONTH / 01/05 12:00PM BACK SET MONTH 1 SET DATE AND TIME SET YEAR 11/ 27/ 12:00PM SET YEAR 05 12PM

5. Programming Your Thermostat

5.1 Programming a Day or Series of Days The PROGRAM MENU is located in the MAIN MENU. After selecting this menu, you have the option of programming everyday, weekdays, weekends, or individual days. Once you’ve selected a certain day to program, a screen appears that allows you to set the time, heat setting and cool setting for each event. Once you have set the correct times and temperatures, highlight DONE and push the SAVE button. The DONE screen will appear to let you know your changes are saved. You have now programmed your thermostat. MONDAY TIME HEAT COOL WAKE 6:00AM 70 78 LEAVE 8:00AM 62 85 RETURN 4:30PM 70 78 SLEEP 10:00PM 70 78 DONE MAIN MENU MORE HOLD PROGRAM PROGRAMMED FAN SETTINGS SET DATE AND TIME EXIT SELECT PROGRAM MENU EVERYDAY WEEKDAYS WEEKENDS MONDAY TUESDAY WEDNESDAY MORE BACK SELECT MONDAY TIME HEAT COOL WAKE 6:00AM 70 78 LEAVE 8:00AM 62 85 RETURN 4:30PM 70 78 SLEEP 10:00PM 70 78 DONE CANCEL SAVE DONE PROGRAM MONDAY WAKE 6:00AM DONE MONDAY TIME HEAT COOL DAY 6:00AM 70 78 NIGHT 8:00AM 62 85 DONE MONDAY TIME HEAT COOL OCC 6:00AM 70 78 UNOCC 8:00AM 62 85 DONE OCC 6:00AM 6:00AM DAY NOTE: When EVENTS PER DAY are set to 2-BUSINESS or 2-RESIDENTIAL (see page 15) the programming screen will look like above. 2-BUSINESS 2-RESIDENTIAL 5.2 Copying a Program from One Day to Another In the PROGRAM MENU, there is an option to COPY. The option can be used to copy the program from one day to another day or series of days (i.e. weekdays or weekends). After COPY is selected, the thermostat will prompt you for which day to copy. Next, it will prompt you for which day to copy the program to. After selecting this information, it will then confirm what is being copied to where. At this point you have the option of canceling the copy and not saving or saving and continuing. After selecting OK, the DONE screen will appear, then it will send you back to the COPY menu. Selecting DONE here will save your copy and return you to the Main Screen. The BACK button will also save your copy and return you back to the PROGRAM MENU. PROGRAM MENU MORE THURSDAY SATURDAY SUNDAY COPY BACK SELECT DONE COPY COPY FROM WHICH DAY? DONE MONDAY TUESDAY WEDNESDAY THURSDAY FRIDAY SATURDAY SUNDAY BACK SELECT COPY TO WHICH DAY? MONDAY TUESDAY WEDNESDAY THURSDAY FRIDAY SATURDAY SUNDAY WEEKDAYS WEEKENDS EVERYDAY BACK SELECT COPY PROGRAM FROM MONDAY TO WEEKDAYS? CANCEL OK COPY FROM WHICH DAY? DONE MONDAY TUESDAY WEDNESDAY THURSDAY FRIDAY SATURDAY SUNDAY BACK SELECT MONDAY WEEKDAYS DONE

6. Holding Temperature

The HOLD MENU, located in the MAIN MENU, allows you to hold a temperature until a set date and time, as would be done during a holiday, or allows you to hold a temperature permanently. 6.1 Holiday Hold You can program the thermostat to hold a temperature for a period of time. Whether you want to hold a temperature for a few hours or for a few weeks, your thermostat can accommodate your schedule. First the thermostat will prompt you for a temperature to hold. If you are in AUTO MODE you will be prompted for both a heat setting and a cool setting. Next it will prompt you for a date and time that you wish to return to programmed operation. On the Main Screen, the INFO button will change to RESUME PROG. If you choose to cancel the hold, simply press this button and the program will resume. You must be in HEAT, COOL or AUTO mode to program a hold; the thermostat will inform you of this if you attempt to HOLD while in the OFF mode. 12 MAIN MENU MORE HOLD PROGRAM PROGRAMMED FAN SETTINGS SET DATE AND TIME EXIT SELECT HOLD MENU HOLIDAY PERMANENT BACK SELECT DONE HOLD HOLIDAY HOLIDAY HOLD MENU SET HOLD TEMPERATURE COOL BACK SAVE 82° HOLIDAY HOLD MENU HOLD UNTIL SET MONTH / 27/05 12:00PM BACK 8 HOLIDAY HOLD MENU HOLD UNTIL SET MINUTES 9/ 04/05 1: PM SAVE 00 SET MONTH SET MINUTES COOL APRILAIRE MODEL 8570 SELECT HEAT OR COOL MODE BEFORE SETTING HOLD NOTE: When installed with an Aprilaire® Model 6504 you will be given the option to CHANGE ALL THERMOSTATS. If you select YES to this, the hold setting will be set on all the thermostats on the system, and pressing the RESUME button returns all thermostats to programmed operation. 6.2 Permanent Hold Similar to the Holiday Hold, the thermostat will prompt you to enter the temperature at which you would like to hold. Once you have selected the temperature, you are returned to the Main Screen. In order to resume the program, simply press the RESUME PROG. button. NOTE: When installed with an Aprilaire® Model 6504 you will be given the option to CHANGE ALL THERMOSTATS. If you select YES to this, the hold setting will be set on all the thermostats on the system, and pressing the RESUME button returns all thermostats to programmed operation. MAIN MENU MORE HOLD PROGRAM PROGRAMMED FAN SETTINGS SET DATE AND TIME EXIT SELECT HOLD MENU HOLIDAY PERMANENT BACK SELECT HOLD PERMANENT 9/11/05 3:15PM OUTDOOR COOL MODE 95° FAN AUTO SETPOINT RESUME COOL 76 PROG. MENU 77° PERMANENT HOLD SET HOLD TEMPERATURE COOL BACK SAVE 76° COOL NOTE: You must not be in the OFF mode when selecting HOLD. The thermostat will remind you to set the mode before completing the HOLD function. APRILAIRE MODEL 8570 SELECT HEAT OR COOL MODE BEFORE SETTING HOLD NOTE: You must not be in the OFF mode when selecting HOLD. The thermostat will remind you to set the mode before completing the HOLD function.

7. Settings Menu

The SETTINGS menu has many options for you to customize your thermostat. 7.1 Fahrenheit and Celsius You can change the temperature scale used by the thermostat. Highlight the scale of your choice and press SELECT. 7.2 12 OR 24 Hour Clock Within this menu option, you can change the time displayed by your thermostat to 24 Hour time, (Military Time). 7.3 Display Setpoints If you do not want the temperature setting displayed on the Main Screen, you can choose to turn it off in this menu. 14 SETTINGS MENU °F OR °C 12 OR 24 HOUR CLOCK DISPLAY SETPOINTS EVENTS PER DAY LOCKOUT OPTIONS MONITORS MORE BACK SELECT SETTINGS MENU MORE SET THERMOSTAT NAME BACK SELECT °F OR °C ADJUST CONTRAST TEMP SCALE °FAHRENHEIT °CELSIUS BACK SELECT °FAHRENHEIT 12 OR 24 HOUR CLOCK 12 HOUR 24 HOUR BACK SELECT 12 HOUR DISPLAY SETPOINTS ON OFF BACK SELECT ON 7.4 Events Per Day This is where you can set the number of events per day. (An event is a period of time scheduled with a certain heating and cooling setpoint.) For instance if you are away from your home from 8am to 5pm, make this period of time an event and set the thermostat at an energy saving setting. You have the option of setting the events per day to 4-RESIDENTIAL (4 events), 2-RESIDENTIAL (2 events), 2-BUSINESS (2 events) or 0-NON PROGRAMMABLE. If you want to set the thermostat so it can only be changed manually, set the events per day to 0-NON PROGRAMMABLE. EVENTS PER DAY 4 - RESIDENTIAL 2 – RESIDENTIAL 2 - BUSINESS 0 – NON PROGRAMMABLE BACK SELECT 4 - RESIDENTIAL 7.5 Lockout Options You have the ability to passcode protect the thermostat against undesired changes. You can completely lockout the thermostat, where no changes of any kind are allowed, or you can limit the changes that can be made. Allowable changes can be limited to temperature settings, by a specified number of degrees, to fan status, to mode of operation, or any combination of the three. To lockout the thermostat, select the LOCKOUT OPTIONS from the SETTINGS MENU then select SET PASSCODE/LOCK. You will then be prompted to enter a passcode. ENTER PASSCODE ENTER FIRST DIGIT 0 0 0 0 BACK ENTER PASSCODE ENTER FOURTH DIGIT 1 2 3 4 SAVE MAIN MENU MORE HOLD PROGRAM PROGRAMMED FAN SETTINGS SET DATE AND TIME EXIT SELECT SETTINGS SETTINGS MENU °F OR °C 12 OR 24 HOUR CLOCK DISPLAY SETPOINTS EVENTS PER DAY LOCKOUT OPTIONS MONITORS MORE BACK SELECT LOCKOUT OPTIONS LOCKOUT OPTIONS SET PASSCODE/LOCK UNLOCK BACK SELECT SET PASSCODE/LOCK

After entering your passcode, you will be prompted to enter the items you want to limit. When the thermostat

has been locked out, the passcode must be entered to change any of the items that have been locked or to enter the MAIN MENU of the thermostat. The thermostat relocks when it returns to the main operating display. “LOCKED” appears in the display Message Center when a thermostat has been locked out. To permanently unlock the thermostat, enter the passcode to get into the SETTINGS MENU, then select UNLOCK from the LOCKOUT OPTIONS menu. LIMITED CHANGES TEMPERATURE CHANGE LIMIT +/- 5° BACK SAVE DONE LOCKED OUTDOOR AUTO MODE 45° FAN AUTO SETPOINT HEAT 70° COOL 78° INFO MENU 72° LOCKOUT OPTIONS CHANGES TO ALLOW NO CHANGES ALLOWED ALLOW LIMITED CHANGES BACK SELECT ALLOW LIMITED CHANGES LIMITED CHANGES ALLOW CHANGES TO FAN SETTING? YES NO BACK SELECT YES LIMITED CHANGES ALLOW CHANGES TO MODE SETTING? YES NO BACK SELECT NO 7.6 Monitors The MONITORS Menu is where you can set your HVAC service reminders. The items that the thermostat will remind you of are servicing your air filter, servicing your humidifier, servicing your UV lamp, and a general service check for your entire system. NOTE: When installed with an Aprilaire® Model 6504 the monitor settings need only to be set on one thermostat. The other thermostats in the system will update with the new setting. NOTE: The ‘AUTO’ option shown above in the SERVICE HUMIDIFIER screen is only available if installed with an Aprilaire® Automatic Digital Humidifier Control. To reset an active monitor: 1. Press the CALL DEALER button. 2. Press the RESET button. 3. This will reset the monitor(s) and return you to the Main Screen. MONITORS AIR FILTER SERVICE HUMIDIFIER UV LAMP HVAC SERVICE TIMER BACK SELECT AIR FILTER HVAC SERVICE TIMER OFF 1 MONTH 3 MONTHS 6 MONTHS 1 YEAR 2 YEAR BACK SELECT OFF UV LAMP OFF 1 YEAR BACK SELECT OFF SERVICE HUMIDIFIER OFF AUTO TWICE/SEASON ONCE/SEASON BACK SELECT OFF AIR FILTER 1 MONTH 3 MONTHS 6 MONTHS 9 MONTHS 1 YEAR BACK SELECT 1 MONTH

8. Info Screen

The Info Screen can be accessed through the Main Screen by pressing INFO button. When pushed, the screen will show the outdoor temperature and indoor relative humidity (when connected to an Aprilaire® Automatic Digital Humidifier Control). Then the thermostat will display the contact information for your HVAC dealer should you have any problems or need any supplies. 7.7 Set Thermostat Name You can give your thermostat a name if you would like. Within this menu, the thermostat gives you some standard choices. Selecting CUSTOM NAME allows you to customize the name for your thermostat. This feature is most useful when installed with a Model 6504 Zoned Comfort Control Panel to more easily identify the thermostats on your system. SET THERMOSTAT NAME GREAT ROOM LIVING ROOM MASTER BEDROOM BEDROOM KITCHEN MORE BACK SELECT GREAT ROOM 7.8 Adjust Contrast The Contrast Adjustment Option allows the user to select a contrast level from 0 (lightest) to 80 (darkest) in increments of 2. Use the Up/Down arrows to adjust the display contrast to an appropriate level; and press SAVE. ADJUST CONTRAST BACK SAVE 60 APRILAIRE MODEL 8570 OUTDOOR INDOOR TEMPERATURE HUMIDITY BACK68°45% APRILAIRE MODEL 8570 XYZ HEATING & COOLING [555] 555 - 1234 XYZHEATING.COM MESSAGES: BACK RESET 9. Viewing Other Thermostats on the System (Model 6504 Installation Only) If installed with an Aprilaire® Model 6504, you have another option in the MAIN MENU. This option is to VIEW OTHER THERMOSTATS. When this is selected a list of other thermostats on the system will be displayed. If you have programmed a name in the THERMOSTAT(S), their respective name(s) will be displayed. If no names are given, you will see default names such as THERMOSTAT 2. When viewing other thermostats, you have the option of temporarily changing the temperature setting or resuming the program. The left multi-function button will be labeled RESUME PROG. if the temperature program is not running. This button would be used to resume the program, for the thermostat being viewed, if it is in hold. Either RESUME PROG. or EXIT returns you to the VIEW THERMOSTAT LIST menu. 10. In Case of Power Failure This thermostat does not require a battery. If the power goes out, the screen is blank. During the period the power is off, the heating/cooling system will not operate. When power is restored, the thermostat will return to the previous settings. If the power is off for more than 2 hours, you will need to reset the clock on the thermostat but all other information will be stored. You will not have to reprogram your thermostat or change any settings that you have previously set. 11. Cleaning If the surface of the thermostat becomes dirty it can be cleaned with plain water or many non-abrasive household cleaners, including glass cleaner. When using any cleaner be careful not to get any into the interior of the thermostat. Do not spray any liquid directly onto the thermostat. Spray the cleaner onto a soft cloth and wipe the surface of the thermostat. VIEW THERMOSTAT LIST THERMOSTAT 1 THERMOSTAT 2 THERMOSTAT 3 THERMOSTAT 4 BACK SELECT THERMOSTAT 1 THERMOSTAT 1 AUTO MODE FAN AUTO SETPOINT HEAT 70° RESUME COOL 78° PROG. EXIT 72° THERMOSTAT 1 MAIN MENU MORE HOLD PROGRAM PROGRAMMED FAN SETTINGS SET DATE AND TIME VIEW THERMOSTAT LIST EXIT SELECT VIEW THERMOSTAT LIST

ELECTRONIC THERMOSTAT FIVE YEAR

LIMITED WARRANTY Your Research Products Corporation Aprilaire® Thermostat unit is expressly warranted for five (5) years from date of installation to be free from defects in materials or workmanship. Research Products Corporation’s exclusive obligation under this warranty shall be to supply, without charge, a replacement for any thermostat which is found to be defective within such five (5) year period and which is returned, together with the date of installation, no later than thirty (30) days after said five (5) year period by you to either your original supplier or to Research Products Corporation, Madison, Wisconsin 53701. THIS WARRANTY SHALL NOT OBLIGATE RESEARCH PRODUCTS CORPORATION FOR ANY LABOR COSTS AND SHALL NOT APPLY TO DEFECTS IN WORKMANSHIP OR MATERIALS FURNISHED BY YOUR INSTALLER AS CONTRASTED TO DEFECTS IN THE THERMOSTAT ITSELF. IMPLIED WARRANTIES OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE SHALL BE LIMITED IN DURATION TO THE AFORESAID FIVE YEAR PERIOD. RESEARCH PRODUCTS CORPORATION’S LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, OTHER THAN DAMAGES FOR PERSONAL INJURIES, RESULTING FROM ANY BREACH OF THE AFORESAID IMPLIED WARRANTIES OR THE ABOVE LIMITED WARRANTY IS EXPRESSLY EXCLUDED. THIS LIMITED WARRANTY IS VOID IF DEFECT(S) RESULT FROM FAILURE TO HAVE THIS THERMOSTAT INSTALLED BY A QUALIFIED HEATING AND AIR CONDITIONING CONTRACTOR. IF THE LIMITED WARRANTY IS VOID DUE TO FAILURE TO USE A QUALIFIED CONTRACTOR, ALL DISCLAIMERS OF IMPLIED WARRANTIES SHALL BE EFFECTIVE UPON INSTALLATION. Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above exclusions or limitations may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. This equipment if installed in strict accordance with the manufacturer’s instructions, complies with the limits for a Class B computing device pursuant to Subpart J of Part 15 of FCC Rules. WARRANTY Please… Take a few minutes to visit us on-line at www.aprilaire.com to register your Aprilaire product. If you do not have on-line access, please mail a postcard with your name, address, phone number, product purchased and date of purchase to: Research Products Corporation P.O. BOX 1467 Madison, WI 53701 WARRANTY REGISTRATION Thank you! Your Warranty Registration information will not be sold or shared outside of this company.

Printed in U.S.A.

RESEARCH PRODUCTS CORPORATION P.O. BOX 1467 • MADISON,WI 53701-1467