ICS ELECTRONICS 9099 Instruction Manual
File Specifications
| Brand: | ICS ELECTRONICS |
| Category: | Switch |
| Model: | 9099 (Instruction Manual), pr.zepscMoZ7w |
| File Info: | Adobe Acrobat PDF (DjVu) |
| File Size: | — |
| Pages: | 178 pages |
Download PDF
Download ICS ELECTRONICS 9099 Manual (178 pages)Read Online:
Read the ICS ELECTRONICS 9099 Instruction Manual online using the built-in PDF viewer. This document explains how to operate the device, adjust settings and perform regular maintenance.
Key Pages of Document
The reload_config procedure is used to cause a reload of the configuration settings.
Any modified configuration settings will be restored to default settings. struct Reload_Config_Resp { unsigned int error; }; Reload_Config_Resp reload_config (void) = 20; If the RPC message is of insufficient length to satisfy the required length, an error value of 1 is returned. The returned Reload_Config_Resp.error value determines whether the default configuration was reloaded. error Meaning 0 No error 1 Syntax error ...
The abort_port_number procedure is used to read/modify the TCP port used
by the VXI-11 abort channel. struct Abort_Port_Parms { unsigned int action; unsigned int port; }; struct Abort_Port_Resp { unsigned int error; unsigned int port; }; Abort_Port_Resp abort_port_number (Abort_Port_Parms) = 4; The action value determines whether the client wishes to execute a read of the current setting, or a modification of the current value. action = 0 = read of current value action = 1 = modify current value If the action value is other than 0 or 1, then an error value of 5 i ...
All configuration messages pertaining to actions shall respond with an RPC
reply and then (if the status is No Error) execute the action. All Edevice configuration commands will reply with statuses corresponding to Error Codes as defined by the VXI-11 (section B.5.2). All Edevice configuration command data will use XDR encoding. Numeri- cal values will be of 4-byte unsigned integer format. String and binary fields will be of opaque array format. Variable length string values will be NULL terminated and will contain a leading length numerical value defining the total length (inclusive o ...
LAN systems have multiple timeouts. There is the VXI-11 IO_timeout which
includes the wait-for-lock-release time and the delays in the module. In the case of the 9099 this also includes the modbus serial timeout value set by the D command. The VISA communication or RPC network timeouts are long timeouts designed to catch network failures. COMM_Timeout is unique to ICS VXI-11 devices and refers to the time the device's service will go without getting a message from the other party before declaring the link dead. KeepAlive is a background function of the device’s TCP/IP Stack to ch ...
Enables generation of a prompt to tell the user that
the 9009 is ready for the next command. Recom-
mended for computer operation. Value is 1(On)
| 0(Off).
:ERRor?
0, “No
Requests next entry in 9099's error
error”
queue. Error messages are:
0, “no error”
-100, “Command error”
-200, “Execution error”
-400, “Query error”
:VERSion?
1994.0
Returns the
UPDATING THE FIRMWARE
The 9009 and 9099's firmware can be updated in the field without returning the unit to the factory. 1. Link to ICS Electronics website at http://www.icselect.com. Click on Downloads and select 90xx Product Updates. Locate the latest ICS_9099_ Update file. Download the .zip file to an temporary directory and unzip the file. 2. Connect the 9099 to a Windows PC as described in paragraph 2.6.1 and turn it on. 3. If the PC is already set to communicate with the 9099 skip this step. Else, disconnect the PC from your company network and change its Local Area Netw ...
The 9099 complies with the VXI-11.3 Specification.
1.4.1 RPC Protocol The RPC protocol conforms to ONC RPC Version 2. 1.4.2 Sockets The 9099's VXI-11 service supports 15 TCP/IP sockets for client communica- tion with a maximum of 4 active sockets. The sockets are normally opened and closed by the clients. The unit will close the socket and release all resources if a broken connection is detected or when the link count goes to zero if Auto Disconnect is enabled. There is a separate socket for UDP RPC Port Mapper communication. 1.4.3 Channels Supports Core, Abort a ...
ICS ELECTRONICS 9099 user guide recommended for: Impact NS5004, 2126-G - Baseline Switch, DSI5100, PE6, DCM/SN DIFF.
⚠️ Download Safety
The Switch Instruction manual (178 pages) is completely safe to download (last scan date: 02/04/2026).
Related PDF Instructions for ICS ELECTRONICS 9099:
-
ICS ELECTRONICS NAV6 V3 Series Receiver Operation & user’s manual
NAV6 V3 Series55 -
ICS ELECTRONICS 4803 Recording Equipment Quick start manual
48036 -
ICS ELECTRONICS 03DVR Series Computer Hardware Quick start manual
03DVR Series4 -
ICS ELECTRONICS NAV6 eNAVTEX V3 System Receiver Installation and quick start manual
NAV6 eNAVTEX V3 System14 -
ICS ELECTRONICS 4803DVR Computer Hardware Quick start manual
4803DVR3 -
ICS ELECTRONICS 4865B Controller Quick start manual
4865B4
Switch Equipment: Frequently Requested
-
Ruby Tech ES-2126C/D Switch
25.02.2026Complete device guide for the Ruby Tech ES-2126C/D Switch. It provides technical information on device overview, installation steps, troubleshooting, application scenarios.ES-2126C/D, 3 -
NETGEAR M4100 Series ProSAFE Switch
27.01.2026User support manual for the NETGEAR M4100 Series ProSAFE Switch. It provides information on installation and user instructions, network setup, specifications.M4100 Series ProSAFE, 446 -
HP STORAGEWORKS ALL-IN-ONE STORAGE SYSTEM Storage
18.03.2026Operation instructions for the HP STORAGEWORKS ALL-IN-ONE STORAGE SYSTEM Storage. It offers details on troubleshooting tips, wiring setup, device operation tips.STORAGEWORKS ALL-IN-ONE STORAGE SYSTEM, 2 -
CoolGear USB3- 16U1 Switch
13.11.2025Service manual for the CoolGear USB3- 16U1 Switch. It includes maintenance procedures and setup, firmware installation, replacement parts.USB3- 16U1, 9 -
Endress+Hauser Liquipoint T FTW31 Measuring Instruments
28.12.2025Complete installation manual for the Endress+Hauser Liquipoint T FTW31 Measuring Instruments. This manual elaborates on hardware setup, diagnostic information, network setup, connectivity options.Liquipoint T FTW31, 42 -
Ruckus Wireless ICX 7450 Switch
18.03.2026Owner’s manual for the Ruckus Wireless ICX 7450 Switch. This documentation covers software installation, control functions, device reset instructions.ICX 7450, 156
Have some Questions about ICS ELECTRONICS 9099 Device?
Get valuable and actionable advices from other ICS ELECTRONICS 9099 device users. Describe your problem or question, regarding the using of 9099, in as much detail as possible, and other users will be able to answer you.