Dynacord DCS 407R Datasheet
Read Online
Read the Dynacord DCS 407R Datasheet online using the built-in PDF viewer.
Text of the manual
Dynacord | DCS 407R
DCS 407R
www.dynacord.com
▪ 4 low frequency relays, 2 switch contacts each.
▪ Gold-plated double contacts for high level of
contact reliability.
▪ Pluggable connection terminals with screwed flange
for all contacts and coils.
▪ 4 relay control LEDs.
The module is fitted on the back of the DCS 400 rack
plug-in board. The module is used to switch audio
signals (line levels) or for control purposes regardless
of the DCS 400 system.
Additional properties:
• Configure the audio distributor by separating the wire
jumpers.
• A monitor bus can be connected.
Parts included
No.
Component
1
DCS 407R
2
Plug, 15-pin (Phoenix MC 1.5/15-STF-3.81 - 1827839)
Technical specifications
Operating voltage
24 V DC, -10%/+30%
Operating current
• Standby
24 V, 5.5 mA, 0.14 W
• Idle/Announcement/Alert
24 V, 42 mA, 1.01 W
Electromagnetical environment
E1, E2, E3
Operating temperature
-5 °C to 45 °C
Product dimensions (Width by
Height by Depth)
37.5 by 80.6 by 245 mm
Net weight
163 g
Relay contacts
• Contacts
2 SPDT
• Contact material
AgPd + 10μ Au
• Contact load (real)
1 A / 24 V DC
0.5 A / 120 V DC
• Contact current max.
2 A
CN to Backplane
CLK1
CLK1_A
CLK2
CLK2_A
CLK3
CLK3_A
RES
RES_A
*RES
*RES_A
DATA1
DATA1_A
DATA2
DATA2_A
DATA3
DATA3_A
DATA4_A
DATA5
DATA5_A
DATA_SEL
EN1
EN1_A
EN2
EN2_A
EN3
EN3_A
EN4
EN4_A
EN5
EN5_A
EN6
EN6_A
EN7
EN7_A
EN8
EN8_A
+24V
GND
MON+
MON-
DATA4_SEL_A
Block diagram
Installation/configuration notes
Installation information
On the DCS 400 rack plug-in board, slots 1–10 must
be occupied in ascending sequence (left to right)
without any gaps. Different module types can
otherwise be arranged in any sequence.
Exception: Slot 1 (far left) must always be occupied
with a DCS 801R control module or DCS 405R
extension module.
When assembling the device and installing the
connections, please comply with the standards VDE
0100 and EN 60065.
Connector
The scope of delivery for the device includes two 15-
pin connectors. Conductor cross-sections of 0.14 mm²
(AWG26) to 1.5 mm² (AWG16) can be used.
Recommended connecting cable: flexible CU strand,
LiY, 0.75 mm².
Certifications and approvals
Status as of November 2012:
• EN 50130-4
• EN 54-16
• EN 55103-1
• EN 55103-2
Ordering information
DCS 407R
Order number F01U121782
2 | DCS 407R
3 | DCS 407R
Represented by:
Germany:
EVI Audio GmbH
Sachsenring 60
94315 Straubing
Germany
www.dynacord.com
© Bosch Security Systems 2013 | Data subject to change without notice
Document Number | Vs1 | 19. Mar 2013