Product Data Sheet
September 2014
00813-0100-4827, Rev DA
Resistance temperature sensors for applications in the food and beverage, pharmaceutical and life-science
industries
Aseptic process connections suitable for CIP and SIP dead-pocket free measurement applications
Exchangeable measuring insert to ensure process integrity
Enhanced system accuracy with transmitter-sensor matching, meets pharmaceutical industry
requirements
Resistance Temperature Sensors for Hygienic
and Sanitary Applications
Product Discontinued
Rosemount 65Q Sensor
Optimize plant efficiency and increase measurement reliability with industry
proven design and specifications
RTD elements for a reliable and accurate measurement point
Available in a wide variety of process connections for sanitary and hygienic applications
Meets EHEDG and 3-A Standard requirements for use in a variety of sanitary
Flying leads, terminal blocks, and cable connections to suit different wiring needs
State of the art manufacturing procedures provide robust element packaging, increasing reliability
Industry-leading calibration capabilities allow for Callendar-van-Dusen values to give increased accuracy when paired with
Rosemount transmitters
Streamline operations and maintenance with sensor and thermowell design
Process connections allow for quick and easy connection to industry-standard sanitary process connection points
Integral thermowell protection on 65Q allows for ordering sanitary sensor and thermowell together
Explore the benefits of a Complete Point Solution from Rosemount Temperature
Measurement
An “Assemble Sensor to Specific Transmitter” option enables Emerson to provide a
complete point temperature solution, delivering an installation-ready transmitter
and sensor assembly.
Emerson has a complete portfolio of Single Point and High Density Temperature
Measurement solutions, allowing you to effectively measure and control your
processes with the reliability you trust from Rosemount products.
Experience global consistency and local support
from numerous worldwide Rosemount Temperature sites
World-class manufacturing provides globally consistent ‘‘‘‘‘‘‘‘‘‘‘
‘
product from every factory and the capability to fulfill the ‘‘‘‘‘‘‘‘
‘
needs of any project, large or small.
Experienced Instrumentation Consultants help select
the right product for any temperature application and
advise on best installation practices.
An extensive global network of Emerson service and support
personnel can be on-site when and where they are needed.
Rosemount 65Q Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Rosemount 65Q Sanitary Sensor . . . . . . . . . . . . . . . . . . . . . . . 4
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Rosemount 65Q Sanitary Sensor
The Rosemount 65Q Sanitary Sensor has designs that provide flexible and
reliable temperature measurements in hygienic process environments.
Features include:
– 50 to 450 °C temperature range
Industry-standard RTD sensor design
3-A and EHEDG Standards approval
Variety of enclosure and connection head options
Global hazardous-location approvals (Option Code I1)
Calibration services to give you insight to sensor performance (Option
Codes V10, V11)
Electropolishing Surface Finish (Option Code R20)
Assemble to Transmitter option (Option Code XA)
Specification and selection of product materials, options, or components must be made by the purchaser of the equipment.
See page 10 for more information on Material Selection.
Table 1. 65Q RTD Assembly (Pt 100) for Hygienic and Food and Beverage Applications
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model
Product description
0065Q
65Q RTD Sensor with Twell for Sanitary Applications
Connection head
IP rating(1)
Connection thread
C
Rosemount Aluminum
68
M20 x 1.5
★
D
Rosemount Aluminum
68
1/2-in. NPT
★
1
Rosemount, Aluminum with LCD Display Cover
68
M20 x 1.5
★
2
Rosemount, Aluminum with LCD Display Cover
68
1/2-in. NPT
★
5
Connection Head DIN A Polished Stainless Steel with LCD Display
Cover
68
M20 x 1.5
★
6
Connection Head DIN A Polished Stainless Steel with LCD Display
Cover
68
1/2-in. NPT
★
E
Connection Head DIN A Polished Stainless Steel
68
M20 x 1.5
★
F
Connection Head DIN A Polished Stainless Steel
68
1/2-in. NPT
★
R
Connection Head DIN B Polished Stainless Steel
66
M20 x 1.5
★
S
Connection Head DIN B Polished Stainless Steel
66
1/2-in. NPT
★
J
GR-A/BL (BUZ), Aluminum
65
M20 x 1.5 (with cable gland)
L
TZ-A/BL (BUZH) Aluminum
65
M20 x 1.5 (with cable gland)
T
TZ-A/BK, Polyamide, Black
65
M20 x 1.5 (with cable gland)
Sensor lead wire termination
0
Flying Leads – No Springs on DIN plate
★
2
Terminal Block – DIN 43762
★
Sensor type
Temperature range
1
RTD, Single Element, 4-wire
– 50 to 450 °C
★
2
RTD, Dual Element, 3-wire
– 50 to 450 °C
★
5
RTD, Single Element, 3-wire
– 50 to 450 °C
★
Extension
S
Tubular with Extension, Welded Screw Bush M24 x 1.5
★
Z
Tubular with Extension, Head Connection Adjustable Loose Screw Nut M24 x 1.5
★
Extension length (N) in millimeters
0050(2)
50 mm
★
0065(3)
65 mm
★
0130
130 mm
★
XXXX
Non-standard extension length – non-standard lengths are available from 50 to 990 mm
★
Thermowell material
D
1.4404 (AISI 316L) Stainless Steel, ≤ 0.8 μm electropolishing
★
Immersion length (L) in millimeters
0025
25 mm – not available for Mounting Style code T02
★
0050
50 mm
★
0065
65 mm
★
0100
100 mm
★
0150
150 mm
★
0200
200 mm
★
0250
250 mm
★
XXXX
Non-standard immersion length – non-standard lengths are available from 25 to 2500 mm
Thermowell mounting style
Process connection
Stem style
C02
Flanged
1-in. Tri-Clamp™ (diameter 50.4 mm)
Stepped, 10/6 mm(4)
★
C04
Flanged
11/2-in. Tri-Clamp (diameter 50.4 mm)
Stepped, 10/6 mm(4)
★
C06
Flanged
2-in. Tri-Clamp (diameter 64 mm)
Stepped, 10/6 mm(4)
★
C08
Flanged
21/2-in. Tri-Clamp (diameter 77.4 mm)
Stepped, 10/6 mm(4)
★
C10
Flanged
3-in. Tri-Clamp (diameter 91 mm)
Stepped, 10/6 mm(4)
★
C12
Flanged
4-in. Tri-Clamp (diameter 119 mm)
Stepped, 10/6 mm(4)
★
C14
Flanged
1/2-in. Tri-Clamp (diameter 24.9 mm)
Stepped, 10/6 mm(4)
★
Table 1. 65Q RTD Assembly (Pt 100) for Hygienic and Food and Beverage Applications
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
3/4-in. Tri-Clamp (diameter 37.4 mm)
Stepped, 10/6 mm(4)
★
K02
Weld-in
Ball (adjustable), diameter 25 mm, PEEK Seal
Straight, 6 mm(5)
★
K04
Weld-in
Ball (adjustable), diameter 25 mm, SST Seal
Straight, 6 mm(5)
★
M10
Tapered with Coupling Nut(6)
Suitable connection for tube nominal size DN 10
Stepped, 10/6 mm(4)
★
M25
Tapered Union with Coupling
Nut(6)
Suitable connection for tube nominal size DN 25
Stepped, 10/6 mm(4)
★
M32
Tapered Union with Coupling
Nut(6)
Suitable connection for tube nominal size DN 32
Stepped, 10/6 mm(4)
★
M40
Tapered Union with Coupling
Nut(6)
Suitable connection for tube nominal size DN 40
Stepped, 10/6 mm(4)
★
M50
Tapered Union with Coupling
Nut(6)
Suitable connection for tube nominal size DN 50
Stepped, 10/6 mm(4)
★
T02
Threaded Parallel
1/2-in. (1/2-in. BSPF) (G1/2)
Stepped, 10/6 mm(7)
★
T12
Threaded Tapered
1/2-in. NPT
Stepped, 10/6 mm(4)
★
V04
VARIVENT® DN 1 1/2 - 3 inch (Dim. 68 mm) Standard
★
Options (include with selected model number)
Sensor options
A3
Single Element Class 1/3 DIN B
Sensor
0 to 100 °C (–32 to 212 °F)
A4
Dual Element Class 1/3 DIN B
Sensor
0 to 100 °C (–32 to 212 °F)
Product certifications
I1
EEx ia ATEX/IBExU Intrinsic Safety Approval
★
Cable gland option
G2
Cable Gland, EEx d, Brass 7.5 mm - 11.9 mm
★
Cover chain option
G3
Cover Chain (only available with Connection Head Material codes C and D)
★
Extension ring
G6
Aluminum Extension Ring for Dual Transmitter Mounting
(only available with Connection Head Material codes C and D)
★
Material certification
Q8
Thermowell Material Certification
★
Extension ring
R20
Electropolishing Surface Finish of wetted parts, Ra = 0.4 μm
Assemble to options
XA(8)
Assemble Sensor to Specific Temperature Transmitter
★
Table 1. 65Q RTD Assembly (Pt 100) for Hygienic and Food and Beverage Applications
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Standard calibration (with A, B, C and Callendar-van Dusen constants)
V10
Works Certificate – Sensor Calibration from –50 to 450 °C (-58 to 842 °F)
★
V11
Works Certificate – Sensor Calibration from 0 to 100 °C (-32 to 212 °F)
★
Temperature range
X8
Works Certificate – Sensor Calibration Over Specified Temperature Range with A, B, C, and Callendar-van Dusen
constants
★
Typical model number:
0065Q
C
0
1
S
0050
D
0200
C04
XA
(1)
IP 68 rating requires a suitable cable gland on the conduit connection thread. All threads must be sealed.
(2)
Standard length for use with Connection Head codes C, D, 1, and 2.
(3)
Standard length for use with Connection Head codes E, F, J, L, R, S, T, 5,and 6.
(4)
For U < 50 mm, outer diameter 6 mm straight, below part of process connection.
(5)
Valid for DIN B connection heads only.
(6)
According to DIN 11851.
(7)
For Up ≤ 65 mm, the outer diameter is 6 mm for straight stem styles.
(8)
If ordering XA with a transmitter, specify the same option on the transmitter model number.
Table 1. 65Q RTD Assembly (Pt 100) for Hygienic and Food and Beverage Applications
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Rosemount Series 65Q Temperature Sensor is designed for use
in hygienic and aseptic applications exclusively to meet the
stringent quality requirements in the Food and Beverage, and
Pharmaceutical industries. Rosemount temperature products
are manufactured according to Good Manufacturing Practice
(GMP) guidelines and comply with the standards of the
European Hygienic Equipment Design Group (EHEDG) as well as
3A standards.
National and international guidelines
Products that may have a direct or indirect impact on public
health, must be produced according to national and
international guidelines. The guidelines contain rules for the
implementation and organization of methods, production,
production environments, and inspections.
The European Hygienic Equipment Design Group (EHEDG) is a
foundation in which mainly users and manufacturers or hygienic
equipment are represented. EHEDG provides guidance of the
hygienic engineering aspects of manufacturing of safe and
wholesome food, e.g. through production, publication, and
updating of guidelines, equipment approval through
certification to assist equipment suppliers and food
manufacturers and advisory function to legislators and
standards groups.
EHEDG cooperation with 3-A
EHEDG cooperates with 3-A Sanitary Standards, Inc. in the
development of hygienic construction material selection and
design standards for food and dairy processing equipment. 3-A
Sanitary Standards and Practices have been developed for use by
the dairy industry, dairy equipment manufacturers, and milk
regulatory agencies as voluntary guidelines. These voluntary
guidelines are used as a benchmark for product performance,
hygienic quality, and ultimately food safety. 3-A Sanitary
Standards and Practices are generally accepted by federal, state,
and local public health authorities in the United States and other
public health authorities around the world.
While 3-A Sanitary Standards have been in development and use
since the late 1920’s. EHEDG is a fairly recent development that
applies test criteria and laboratory test data for determining
cleanability and acceptance for equipment use in the processing
of foods or comestibles. Both EHEDG and 3-A Sanitary Standards
may be applied not only to Food and Beverage processing
equipment, but can also be applied to Biotech and Bio-pharm
equipment to ensure product acceptance and safety.
Mounting configurations
The Rosemount 65Q can be ordered with flying leads or terminal
block. Ordered with flying leads, the sensors are designed with
an integral mounting plate, and are for use with a head-mount
transmitter attached directly to the sensor. The flying lead
configuration facilitates removal of the sensor and transmitter
as one assembly. The configuration with terminal block allows
only the mounting of transmitter into the cover of several DIN
size connection heads or requires the use of field mount
transmitter.
Series 65Q RTD – sanitary applications
Rosemount Series 65Q Integral Mount Temperature Sensors are
designed for use in hygienic, food and beverage applications
when fitted with the Tri-Clamp, adjustable Weld-in Ball or
Tapered Union with Coupling Nut according to DIN 11851 (Dairy
Connection) process connections which do not need to meet as
harsh aseptic requirements as requested for BioPharm
applications. Alternatively for direct insertion into non-hygienic
processes, the Series 65Q Temperature Sensor can be ordered
optional with G½-in. (½-in. BSPF) or ½-in. NPT thread mounting.
The 65Q is available alone or as complete assemblies including
connection heads, thermowells with weld-on process
connections. This offering is designed to be used in complete
temperature assemblies including Rosemount Temperature
Transmitters. The RTD sensors meet most critical parameters of
international standards - DIN EN 60751 incorporating
Amendments 1 and 2. All sensors are available in a variety of
lengths and ranges with terminal block or flying leads.
Figure 1. Rosemount 65Q Lead Wire Termination
Series 65 RTD flying leads (Code 0)
Single element
3-wire
Single element
4-wire
Dual element
3-wire
Series 65 RTD terminal block termination (Code 2)
Single element
3-wire
Single element
4-wire
Dual element
3-wire
Red
Red
White
Red
Red
White
White
Red
Red
Green
Black
Blue
Blue
White
Red
Red
Red
Red
White
White
White
White
Red
Red
Red
Red
Emerson provides a variety of Rosemount product with various
product options and configurations including materials of
construction that can be expected to perform well in a wide
range of applications. The Rosemount product information
presented is intended as a guide for the purchaser to make an
appropriate selection for the application. It is the purchaser’s
sole responsibility to make a careful analysis of all process
parameters (such as all chemical components, temperature,
pressure, flow rate, abrasives, contaminants, etc.), when
specifying product, materials, options and components for the
particular application. Emerson Process Management is not in a
position to evaluate or guarantee the compatibility of the
process fluid or other process parameters with the product,
options, configuration or materials of construction selected.
Nominal resistance
In accordance with DIN EN 60751, the nominal resistance is
defined as follows:
100 Ω RTD at 0 °C
Temperature coefficient α = 0.00385 Ω x °C/Ω), averaged
between 0 and 100 °C
Limit deviations
Tolerance Class A as standard: t = ± (0.15 + 0.002 x t);
valid for the temperature range from 0 to +350 °C
Lead wire configuration
As single element (1Pt 100) with 3 or 4 lead wires or dual
element (2Pt 100) with 3 lead wires
Response time
Less than 12 seconds to reach 63% step change in water flowing
at 0.4 m/s
Process temperature range
-50 to +450 °C
The measurement range can be limited by the gasket in the
process connection.
Ambient temperature
Housing without head-mounted transmitter
Metal housings: -40 to +130 °C
Plastic housings: -40 to +85 °C
Housing with head-mounted transmitter
-40 to +85 °C
Maximum process pressure
Lower maximum pressure can be due to the process connection
Pressure ratings at 20 °C:
Tri-Clamp: 10 bar
Weld-in Ball with PEEK-Seal: 6 bar
Weld-in Ball with SST-Seal: 40 bar
Threaded: 40 bar
Tapered Union with Coupling Nut: 10 bar
VARIVENT: 10 bar
Shock and vibration resistance
According to DIN EN 60751: 2.8 g peak / 10…500 Hz
Self heating
0.15 °K/mW when measured per method defined in DIN EN
60751
Insulation resistance
1,000 MΩ minimum insulation resistance when measured at
500 Vdc and at room temperature
Sheath material
321 Stainless Steel with mineral-insulated cable construction
Lead wire
PTFE insulated, silver coated copper wire
The model and serial numbers are marked on each sensor.
Ingress Protection (IP) ratings
The particular rating is applicable only for complete assemblies
including a connection head and tubular thermowell. IP varies
from 65 to 68 due to a wide selection on different connection
heads, DIN A and B size, made of different materials such as
aluminum, polyamide, and stainless steel.
System components
Sensor
The 65Q sensor consists of an exchangeable mineral-insulated
measuring insert, wherein a small, drop-form thin film RTD
element is encapsulated. This design protects the relatively
strain-free element, thereby maintaining accuracy and
long-term stability. The sensor is mounted into a swaged or
straight stainless steel sheath. The sensor outer diameter is 3.2
mm. The minimum sensor length for an exchangeable sensor is
100 mm. The RTD sensor is fitted into a housing with connection
head and welded thermowell.
Extension
Standard material Stainless Steel 1.4404 (316 L)
Standard diameter of 10 mm
Preferred standard lengths; 50, 65, and 130 mm
Thermowell
Thermowell stem styles
Straight thermowell with an outer diameter of 6 mm diameter
must be used for immersion lengths less than 50 mm
More stable Stepped Thermowell with an outer diameter of
10mm reduced to 6 mm must be used for immersion lengths
greater than 50 mm (65 mm on parallel thread G1/2-in.
(1/2-in. BSPF))
Thermowell materials
Stainless Steel 1.4404 (316L) for hygienic applications
Thermowell surface qualities
Ra < 0,8 μm as standard, electropolishing
Ra < 0,4 μm optional, electropolishing
Connection heads (see Table 2)
The connection heads can be of different types (size DIN A and
B) and materials (plastic, aluminum, stainless steel). Its fitting to
the rest of the probe and the gland for the cable entry, assure an
IP grade of 65 at minimum. All supplied heads have a process
connection M24x1.5.
Polished stainless steel DIN A (sanitary applications)
Smoothly contoured design which minimizes crevices for easy
wipe-down
Sanitary Stainless Steel housing for easy-to-clean applications
Mounting of one DIN A or B sized transmitter on DIN plate
Local indication with integral LCD Display Meter
Polished stainless steel DIN B (sanitary applications)
Smoothly contoured design which minimizes crevices for easy
wipe-down
Sanitary Stainless Steel housing for easy-to-clean applications
Mounting of one DIN B sized transmitter on DIN plate
Rosemount aluminum DIN A
Rosemount design
Mounting of one or two transmitters on DIN plate and for
second one optional by the use of extension ring
TZ-A/BL (BUZH)
DIN B head with enlarger space for mounting a DIN A size
(644H) or DIN B size transmitter into the cover by the use of
terminal block or two transmitters with flying lead sensors
GR-A/BL (BUZ)
DIN B head with enlarger space for mounting a DIN A size
(644H) or DIN B size transmitter on DIN plates
TZ-A/BK
DIN B head with enlarger space for mounting a DIN A size
(644H) or DIN B size transmitter into the cover by the use of
terminal block or two transmitters (248H) with flying lead
sensors
Suggested for use in high humidity environments and at low
temperatures to avoid problems due to condensation
Table 2. Connection Head Features
Type
Material
IP
rating Lid version
Transmitter mounting
Conduit
connection
LCD display
meter cover
Polished DIN A
SST
68
Threaded
DIN plate, 644, 248
M20 x 1.5, 1/2-in. NPT
Yes
Polished DIN B
SST
66
Threaded
DIN plate, 248
M20 x 1.5, 1/2-in. NPT
No
Rosemount
Aluminum
68
Threaded
DIN plate, 644, 248
M20 x 1.5, 1/2-in. NPT
Yes
TZ-A/BK
Polyamide
65
Screw-on cap
On cover, terminal block 644, 248
M20 x 1.5
No
TZ-A/BL
Aluminum
65
Screw-on camp
On cover, terminal block 644, 248
M20 x 1.5
No
GR-A/BL
Aluminum
65
Screw-on camp
DIN plate, 644, 248
M20 x 1.5
No
Mounting style and process connection
Achieving absolute control through every step of the
manufacturing process is essential in order for the production of
sanitary fittings to be successful. By achieving such control, each
fitting will perform more satisfactorily when incorporated into
the process installation, reducing installation time, and ensuring
process integrity.
Process connections are available in several sizes
Process connection is continuously welded on the thermowell
in such a way to obtain a welding radius of 3.2 mm at
minimum, between the lower surface of the connection and
the sensor stem according to 3A standards
All process connections are available in material 1.4404
(316L)
Surface roughness on wetted parts: Ra of ≤ 0.8 μm is available
as standard, optional with Ra ≤ 0.4 μm, both electropolishing
Tri-Clamp
Welded on the thermowell it allows immersion lengths from
25 to 500 mm, they depend on pipe nominal size used; see
details on dimension table
Available in 1/2 -to-4 in. (19 to 10.16 mm) tube OD sizes, larger
sizes than 4-in. are available upon request
Available in material 1.4404 (316L), surface finish Ra of ≤ 0.8
μm is available as standard, optional with Ra of ≤ 0.4 μm, both
electropolishing
Can be cleaned in place, fast and easy to take down, provide
lead-tight connections and readily adaptable to other forms
of piping, allow in-line temperature measurement by the use
of counter part and suitable seal O-ring on customer site
Meet the 3-A Sanitary Standard
Meets ASME BPE 2002 standards
Tapered union with coupling nut according to DIN
11851 (dairy connection)
Immersion lengths from 25 to 500 mm
Available in DN10 - DN50 tube OD sizes, larger sizes than 50
DN are available upon request
Available in material 1.4404 (316L), surface finish Ra of ≤ 0.8
μm is available as standard, optional with Ra of ≤ 0.4 μm, both
electropolishing
Self-centering, external coupling nut can be easily cleaned
26
N
U
T
D
T1
D = Process Connection Diameter
T1 = Extension Outer Diameter
T = Thermowell Outer Diameter
U = Immersion Length
N = Extension Length
Dimensions (mm)
Nominal size
D
T
T1
1/2-in. (12.7 mm)
24.9
6(1)
(1)
Diameter 6 mm as standard for immersion
length U ≤ 50 mm. For U ≥ 50 mm Stepped
thermowell diameter 10 mm with reduced
measuring tip of 6 mm.
10
3/4-in. (19 mm)
24.9
6(1)
10
1-in. (25.4 mm)
50.4
6(1)
10
11/2-in. (38 mm)
50.4
6(1)
10
2-in. (50.8 mm)
63.9
6(1)
10
21/2-in. (63.5 mm)
77.4
6(1)
10
3-in. (76.2 mm)
90.9
6(1)
10
4-in. (101.6 mm)
119.1
6(1)
10
Dimensions (mm)
Nominal size
D
B
T
T1
DN 10
22.5
38
6(1)
(1)
Diameter 6 mm as standard for immersion
length U ≤ 50 mm. For U ≥ 50 mm Stepped
thermowell diameter 10 mm with reduced
measuring tip of 6 mm.
10
DN 25
44
63
6(1)
10
DN 32
50
70
6(1)
10
DN 40
56
78
6(1)
10
DN 50
68.5
92
6(1)
10
26
N
U
T1
T
D
B
D = Process Connection Diameter
T = Thermowell Outer Diameter
T1 = Extension Outer Diameter
UP = Immersion Length (parallel)
UT = Immersion Length (tapered)
NP = Extension Length (parallel)
NT = Extension Length (tapered)
Weld-in ball connection
Immersion lengths from 25 to 500 mm, mostly used for
temperature measurement in vessels
Available in material 1.4404 (316L), surface finish Ra of ≤ 0.8
μm is available as standard, optional with Ra of ≤ 0.4 μm, both
electropolishing
Used for Food and Beverage applications
Available with PEEK or SST seal
Threaded process connection
Immersion lengths from 25 mm (tapered threads) and 40 mm
(parallel threads) to 500 mm
Available in material 1.4404 (316L)
Used for temperature measurement in non-hygienic processes
VARIVENT process connection
Immersion lengths from 35 to 500 mm
Available in D = 68 mm
Suitable for hygienic and aseptic applications
PARALLEL
26
NP
UP
T
T1
TAPERED
26
NT
UT
T
T1
26
N
T
D
U
D = Process Connection Diameter
T = Thermowell Outer Diameter
U = Immersion Length
N = Extension Length
Dimensions (mm)
T
T1
6(1)
(1)
Diameter 6 mm as standard for
immersion length UT ≤ 50 mm or
Up ≤ 65 mm. For UT ≥ 50 mm or Up
≥ 65 mm Stepped thermowell
diameter 10 mm with reduced
measuring tip of 6 mm.
10
Dimensions (mm)
Nominal size
D
DN 32 - 125
68
26
N
U
6
25
U = Immersion Length (adjustable)
N = Extension Length (adjustable)
Series 65Q Temperature Sensors can be mounted on the wall of
pipes or vessels. The counterparts for the process connections
and the respective gaskets or sealing rings are generally not
supplied with the sensors, and are on the customer's
responsibility (FDA material certification, EHEDG and 3A
requirements shall be observed).
As a general rule, the sensors should be installed in a manner
which does not adversely affect their ability to be cleaned.
The immersion length may have an influence on the accuracy of
the sensors, If it is too short, an error might be generated in the
measured temperature, due to the lower temperatures of the
process medium near the walls and the heat transfer which
occurs through the sensor stem. To avoid this effect of
inaccuracy, the immersion length should be, if possible, at least
90 to 120 mm. In pipes with smaller diameter, the axis line of the
duct must be reached, and even slightly exceeded by the sensor
tip.
In hygienic applications a strict installation rule exists so as not
to leave any dead spaces along the run of process fluid.
In case of disassembling of the sensor, new gaskets equal to the
originals and specific torques must be employed for the
reassembly procedure, to assure the stated IP grade of the
connection heads.
TriClamp Flange partially fulfills this requirement.
For Weld-in Ball Connection, care should be taken by the user
in the execution of the welding on the process side; e.g. suitable
weld material, welding radius > 3 mm, absence of pits, crevices
etc.)
Tapered Union with Coupling nut according to DIN 11581
(Dairy Process Connection) process connection doesn't meet
as harsh aseptic requirements as requested for BioPharm
applications.
Alternatively, for direct insertion into non-hygienic processes,
the Series 65Q Temperature Sensor can be ordered with
optional G1/2-in. (1/2-in. BSPF) or NPT thread mounting.
Figure 2. Installation Drawing
h
Codes C, D, 1, 2
DIN A
SST
Codes, E, F, 5, 6
DIN B
Polished SST
Codes R, S
TZ-A/BL
Aluminum
Code L
FR-A/BL
Aluminum
Code J
TZ-A/BK
Polyamide
Code T
40
25
25
25
25
25
Sensor Lead Wire Terminations
Flying leads
Code 0
Terminal block
Code 2
3.2
L
L
3.2
All dimensions are in millimeters.
Thermowells and Process Connections
Tri-Clamp
Weld-in ball (adjustable)
Tapered union with coupling nut
Threaded tapered
Threaded parallel
Stepped thermowell
Straight thermowell
VARIVENT
Standard Terms and Conditions of Sale can be found at www.rosemount.com\terms_of_sale
The Emerson logo is a trade mark and service mark of Emerson Electric Co.
Tri-Clamp, Rosemount, and the Rosemount logotype are registered trademarks of Rosemount Inc.
VARIVENT is a registered trademark of GEA Process Engineering Limited.
All other marks are the property of their respective owners.
© 2014 Rosemount Inc. All rights reserved.
Emerson Process Management
Rosemount Inc.
8200 Market Boulevard
Chanhassen, MN 55317 USA
T (U.S.) 1-800-999-9307
T (International) (952) 906-8888
F (952) 906-8889
www.rosemount.com
Emerson Process Management
Blegistrasse 23
P.O. Box 1046
CH 6341 Baar
Switzerland
T +41 (0) 41 768 6111
F +41 (0) 41 768 6300
www.rosemount.com
Emerson Process Management
Asia Pacific Pte Ltd
1 Pandan Crescent
Signapore 128461
T +65 6777 8211
F +65 6777 0947
Service Support Hotline: +65 6770 8711
Email: [email protected]
www.rosemount.com
Rosemount 65Q
00813-0100-4827 Rev DA
Product Data Sheet
September 2014
Emerson Process Management
Latin America
1300 Concord Terrace, Suite 400
Sunrise, Florida 33323 USA
T + 1 954 846 5030
www.rosemount.com