Alfa Laval AlfaNova 14-76, AXP AN Instruction Manual
File Specifications
| Brand: | Alfa Laval |
| Category: | Industrial Equipment |
| Model: | AlfaNova 14-76, AXP AN (Instruction Manual), prwR4U5ZNDpbI |
| File Info: | Adobe Acrobat PDF (DjVu) |
| File Size: | — |
| Pages: | 26 pages |
Download PDF
Download Alfa Laval AlfaNova 14-76, AXP AN Manual (26 pages)Read Online:
Read the Alfa Laval AlfaNova 14-76, AXP AN Instruction Manual online using the built-in PDF viewer. This document explains how to operate the device, adjust settings and perform regular maintenance.
Key Pages of Document
If several pumps are included in the system, make
sure you know which one should be activated first. Note! Adjustments of flow rates should be made slowly in order to avoid the risk of water hammer. Water hammer is a short-lasting pressure peak that can appear during start-up or shut-down of a system, which causing liquids to travel along a pipe as a wave at the speed of sound. This can cause considerable damage to the equipment. Step 1 Check that the inlet valve (2) is closed between the pump and the unit controlling the system flow rate. Inlet valve (2, ...
It is recommended to mount the plate heat exchanger on the
floor, on feet or on the wall. Larger heat exchangers should be secured with support mountings (ordered as accessory) intended for a specific heat exchanger, or be secured with straps or by means of mounting bolts. Note! Regardless of the mounting method minimize the pipe loads at installation. Maximum tightening torques for the mounting bolts according to table below. Bolt dimension Torque Nm lbf*ft M5 2.3 1.7 M6 3.8 2.8 M8 9.5 7.0 M8 (Extra small units) 8.0 5.9 M10 19.0 14.0 M12 33.0 24.3 UNC 1/4” 3.8 2.8 UN ...
When all air is expelled, close the vent valve (5).
Step 6 Repeat steps 1–5 for the second media. Unit in operation Note! Adjustments of flow rates should be made slowly in order to protect the system against sudden and extreme variations of temperature and pressure. During operation, check that: • media temperatures and pressures are within the limits stated on the name plate • no leakages appear due to faulty tightening of the connections. Protection against connection loads Make sure that the heat exchanger is fastened to avoid or minimize connection loads during ope ...
Protection against thermal or/and pressure fatigue
Sudden temperature and pressure changes could cause fatigue damage to the heat exchanger. Therefore, the following must be taken into consideration to ensure that the heat exchanger operates without fluctuating pressures/temperatures. Warning! The plate heat exchanger is not intended for cyclic processes, please contact an Alfa Laval Representative for advice. • Locate the temperature sensor as close as possible to the outlet from the heat exchanger. • Choose valves and regulation equipment which give stable temperatures/pressur ...
If several pumps are included in the system, make
sure you know which one should be activated first. Note! Adjustments of flow rates should be made slowly in order to avoid the risk of water hammer. Water hammer is a short-lasting pressure peak that can appear during start-up or shut-down of a system, which causing liquids to travel along a pipe as a wave at the speed of sound. This can cause considerable damage to the equipment. Step 1 Check that the inlet valve (2) is closed between the pump and the unit controlling the system flow rate. Inlet valve (2, ...
If several pumps are included in the system, make
sure you know which one should be stopped first. 1. Slowly reduce the flow rate in order to avoid water hammer. 2. When the valve is closed, stop the pump. 3. Repeat steps 1–2 for the other medium/media. 4. If the plate heat exchanger is shut down for a long period, it should be drained. Also, drain the heat exchanger if the process is shut down and the ambient temperature is below the freezing temperature of the media. Depending on the media processed, rinse and dry the heat exchanger and its connections. Document ...
Alfa Laval AlfaNova 14-76, AXP AN user guide recommended for: M3, FrontLine ClipLine, T35, IsoMix External Drive, LeviMag.
⚠️ Download Safety
The Industrial Equipment Instruction manual (26 pages) is completely safe to download (last scan date: 09/03/2026).
Related PDF Instructions for Alfa Laval AlfaNova 14-76, AXP AN:
-
Alfa Laval A MRPX 614HGV-14C Water Filtration Systems Operator's manual
A MRPX 614HGV-14C62 -
Alfa Laval FOPX 610TFD Water Filtration Systems Manual
FOPX 610TFD218 -
Alfa Laval ALS Series Industrial Equipment Instruction manual
ALS Series50 -
Alfa Laval Toftejorg Cleaning Equipment Instruction manual
Toftejorg40 -
Alfa Laval Arctigo HRCD 06-I Air Conditioner Original instruction
Arctigo HRCD 06-I16 -
Alfa Laval ThinkTop v.3.0 Controller Instruction manual
ThinkTop v.3.040
Industrial Equipment Equipment: Frequently Requested
-
Midmark Ritter 105 Series Industrial Equipment
22.02.2026Operational manual for the Midmark Ritter 105 Series Industrial Equipment. It includes maintenance procedures and usage procedures, configuration options, setup.Ritter 105 Series, 22 -
Miller SRL2-M Series Industrial Equipment
06.01.2026Owner’s guide for the Miller SRL2-M Series Industrial Equipment. The document highlights operating procedures and support details, warranty information, power requirements, user preferences.SRL2-M Series, 32 -
John Crane 5611 Industrial Equipment
11.03.2026User instruction booklet for the John Crane 5611 Industrial Equipment. It explains configuration options and troubleshooting tips, technical troubleshooting, component replacement, application scenarios.5611, 6 -
Siemens SIPROTEC 5 Controller
02.05.2026Comprehensive guide for the Siemens SIPROTEC 5 Controller. This manual outlines usage tips, system setup, software configuration.SIPROTEC 5, 63 -
Indutherm VC 400 LCD Industrial Equipment
11.02.2026Setup instructions for the Indutherm VC 400 LCD Industrial Equipment. The manual provides information on service procedures, safety precautions, operating guidelines.VC 400 LCD, 42 -
Siemens RUGGEDCOM ROX II Network Hardware
30.11.2025Maintenance instructions for the Siemens RUGGEDCOM ROX II Network Hardware. The guide offers support information and troubleshooting guides, configuration options, troubleshooting, technical guidelines.RUGGEDCOM ROX II, 664
Have some Questions about Alfa Laval AlfaNova 14-76, AXP AN Device?
Get valuable and actionable advices from other Alfa Laval AlfaNova 14-76, AXP AN device users. Describe your problem or question, regarding the using of AlfaNova 14-76, AXP AN, in as much detail as possible, and other users will be able to answer you.