Andrew OneBase Cell Extender Operation Instructions Manual
Text of the manual
Andrew Corporation – Base Station Systems Group
Proprietary – Use pursuant to Company Instruction
OneBase™ Cell Extender
Model: OBE-DB-X
Operation Instruction
December 20, 2006
Version. 1.0
Reference Numbers:
FCC ID: S8L-OBEMCPA
IC:2237F-OBEMCPA
Andrew Corporation – Base Station Systems Group Page 1
Proprietary – Use pursuant to Company Instruction
Introduction:
The OneBase™ Cell Extender subrack is a high-power, mixed-mode RF front-end
equipment solution which provides signal amplification and conditioning for both uplink
and downlink cellular base station signals. It is a highly modular design, consisting of a
minimal set of unique field-replaceable units, capable of being configured and scaled for
a variety of system level capacities and air interfaces including TDMA, GSM/EDGE,
CDMA, WCDMA and analog air interfaces.
System Specifications:
System specifications for the OneBase™ Cell Extender Subrack are:
Parameter
Specification
Frequency Bands
850 MHz Band Tx: 869-894 MHz
1900 MHz Band Tx: 1930-1990 MHz
25 MHz (29 MHz for -20dB bandwidth, nominal)
Operation Bandwidth
60 MHz (70 MHz for -20dB bandwidth, nominal)
Input / Output Impedances
50 Ohms
Supply Voltage
+21 VDC to +30 VDC
Nominal Passband Gain (dB)
55 dB +/- 1 dB
Power Amplifier Module Power
Rating
135 Watts
Subrack Capacity
4 MCPAs
Total Rated Mean Output Power
426 Watts (+56.3 dBm)
Supported Output Power (Typical)
40 Watts/carrier (WCDMA)
25 Watts/carrier (TDMA)
25 Watts/carrier (CDMA)
25 Watts/carrier (GSM/EDGE)
DC current draw
<140 Amps per Subrack
In-Band emissions
-13 dBm/MHz
Receive Path Noise Figure
3.5 dB
Andrew Corporation – Base Station Systems Group Page 2
Proprietary – Use pursuant to Company Instruction
Functional Blocks:
The OneBase™ Cell Extender subrack is comprised of the following functional blocks:
− RFIM (Radio Frequency Interface Module):
− MCPAs (Multi-carrier Power Amplifiers—850 MHz or 1900 MHz)
− SCM (Switch Combiner Module)
− Filter Module (850 MHz or 1900 MHz)
− PDP (Power Distribution Panel)
− Inputs and Outputs
Inputs and Outputs:
The amplifier is powered from a DC supply voltage which can range from 20VDC-to-
30VDC (with a nominal voltage of 27 VDC). The DC power is brought into the subrack
at a terminal that is in the back of the subrack.
The RF signal is brought into the RFIM, passes into the amplifers, then through the SCM
which is blind-mate connected to the amplifiers, and finally into the Filter Modules and
subsequent antenna ports.
Andrew Corporation – Base Station Systems Group Page 3
Proprietary – Use pursuant to Company Instruction
System Pictures:
Front View
Rear View
Andrew Corporation – Base Station Systems Group Page 4
Proprietary – Use pursuant to Company Instruction
Alarm System:
Alarms and operating state are communicated to the BTS via connections to the “Alarm
Terminal Block” at the back of the subrack. The terminal block is internally connected to
dry-contact relays which are located in the MCPA subracks.
ALARM
CATEGORY
SEVERITY
Minor
Conditions that do not immediately affect system operation, but lead to more serious problems if
ignored.
Major
Conditions that directly affect amplifier operation (e.g. reduced gain), but allow the system to
continue operating.
Critical
Conditions which result in sector shutdown, preventing any further cellular call traffic.
MCPA LEDs
MCPA LED
Status
Alarm Severity
Possible Failure Modes
Green: “ON”
Yellow: ON”
Red: “ON”
Initial Power-up of
MCPAs.
NONE
LEDs all “ON” simultaneously for about 2 seconds.
Green: “ON”
Normal Operation
NONE
Green: “ON”
Yellow: ON”
Minor
1. MCPA Fan(s) failure
2. MCPA high internal temperature (approximately between 80°C
and 90°C).
3. MCPA values indicating: Poor Return Loss (3-8 dB)
Yellow: ON”
Major
1. RF disabled via MCPA panel switch or RFIM command
2. RF Overdrive (gain reduced)
3. DC voltage out of normal range
Red: “ON”
Critical
1. MCPA internal failure
2. RF Overdrive (> 10 dB)
3. MCPA high internal temperature
(above approximately 90°C).
4. MCPA values indicating: Poor Return Loss (0-3 dB)