Amprobe GP-2 GeoTest Instruction Manual
File Specifications
| Brand: | Amprobe |
| Category: | Test Equipment |
| Model: | GP-2 GeoTest (Instruction Manual), prmTl2EnaLeHU |
| File Info: | Adobe Acrobat PDF (DjVu) |
| File Size: | — |
| Pages: | 41 pages |
Download PDF
Download Amprobe GP-2 GeoTest Manual (41 pages)Read Online:
Read the Amprobe GP-2 GeoTest Instruction Manual online using the built-in PDF viewer. This document explains how to operate the device, adjust settings and perform regular maintenance.
Key Pages of Document
EN - 18
Press SAVE to store the test results in memory (see paragraph 5.1). Example: You position the rods at a distance D of 3 feet and take 3 resistivity measurements: 7.7 7.7 Ω Ωm ρρ 7.1 7.1 Ω Ωm ρρ A A dd 7.1 7.1 Ω Ωm ρρ A A dd 1st meas. 2nd meas. 3rd meas. a) 1st measurement: you see the measured value but not the message “Add”. b) 2nd measurement: you see the message “Add”. This means that the second measurement is included in the calculation of the average; by pressing AVG you will get also the average value calculated. 7.4 7.4 Ω Ωm ρρ 002 ...
EN - 33
10. SERVICE 10.1. WARRANTY This instrument is guaranteed against any defects in material and manufacturing for one year, in compliance with the general sale terms and conditions. During the warranty period all defective parts may be replaced, but the manufacturer reserves the right to repair or replace the product. If the instrument is to be returned, its transport expenses must at the customer's expense. Shipping instructions may be obtained by contacting the factory. A Return Material Authorization (RMA) number must be obtained from the factory prior to return. A report ...
EN - 17
NOTE! Regardless on the unit of distance D, which is set up (either ft or m) the resistivity will be automatically calculated in OhmMeters! WARNING: When the message “Measuring” appears on the display, the instrument is measuring. Do not disconnect the alligator clips during the measurement. NOTE! If you keep pressing GO, the instrument takes more measurements consecutively. When a new value is acquired, the symbol Ωm blinks on the main display, the instrument emits a short sound and, if the measured value is inserted in the calculation of the average resistivity ...
EN - 20
F νν - - - - - - PP cc In case both the amperometric circuit and the voltmetric circuit are interrupted, when pressing GO the instrument will not read the minimum current nor the minimum voltage, therefore a screen similar to the one beside appears. Make sure that the terminals are connected correctly and that the amperometric and voltmetric rods (blue and red conductors) have not been driven into a gravely or scarcely conductive ground. If necessary, pour water around the rod. THIS RESULT CANNOT BE SAVED. F νν> >1999 1999 Ω Ω - - - - - - - - - ...
EN - 34
A report should accompany the returned product, stating the reason(s) for return. The unit should be packed in its original carton or equivalent; any damage that may be due to non-original packing shall be charged to the customer. The manufacturer disclaims any responsibility for damages caused to people and/or objects. ...
EN - 5
2. GENERAL DESCRIPTION Thank you for purchasing a quality AMPROBE Test Instrument. This instrument will provide you with accurate and reliable measurements provided that it is used according to this manual’s instructions The GP-2 GeoTest is able to measure: F EARTH 2 WIRES: 2 wires earth resistance F EARTH 3 WIRES: 3 wires earth resistance F ρρ: 4 wires earth resistivity The GP-2 GeoTest uses the "Fall of potential" method of measurement for all of the above tests. ...
EN - 11
secondary display on the left-hand side = 003 (no. of measurements = 3 means that 3 earth measurements have been taken consecutively) secondary display on the right-hand side = average of the measurements taken ((Val1+Val2)/no. of measurements = (0.90+0.96+0.93)/3 = 0.93Ω) NOTE! A test with a result over 700Ω is not inserted in the calculation of average value. Example: 1st measurement Main display: 1,07Ω Secondary display on the left-hand side: 1 Secondary display on the right-hand side: 1,07Ω 2nd measurement Main display: 4,15Ω Secondary display on the left-han ...
Amprobe GP-2 GeoTest user guide recommended for: DGC-1000A, gp-2a, VPC-30, PRM-6, CT238A.
⚠️ Download Safety
The Test Equipment Instruction manual (41 pages) is completely safe to download (last scan date: 08/12/2025).
Related PDF Instructions for Amprobe GP-2 GeoTest:
-
Amprobe ULD-400 Series Security Sensors Operation & user’s manual
ULD-400 Series66 -
Amprobe IR608A Thermometer Operation & user’s manual
IR608A64 -
Amprobe LCR55A Measuring Instruments Operation & user’s manual
LCR55A41 -
Amprobe CT235A Test Equipment Operation & user’s manual
CT235A28 -
Amprobe DM73C Multimeter Operation & user’s manual
DM73C55 -
Amprobe IRC-120 Thermal cameras Operation & user’s manual
IRC-12074
Test Equipment Equipment: Frequently Requested
-
Coretec Trainer 1000 SE Test Equipment
23.12.2025User handbook for the Coretec Trainer 1000 SE Test Equipment. This guide offers guidance on usage tips, service contacts, energy usage, maintenance guidelines.Trainer 1000 SE, 10 -
audioscan RM500SL Measuring Instruments
21.04.2026Operating instructions for the audioscan RM500SL Measuring Instruments. The manual outlines system configuration and installation procedures, security instructions, operating conditions.RM500SL, 126 -
Webasto Hollandia 900 Automobile Accessories
22.01.2026Official operating instructions for the Webasto Hollandia 900 Automobile Accessories. It offers guidance on calibration steps, system parameters, functional overview, component overview.Hollandia 900, 8 -
Teledyne Lecroy AP033 Measuring Instruments
25.02.2026User instruction booklet for the Teledyne Lecroy AP033 Measuring Instruments. This guide includes detailed instructions for error handling, network setup, dimensions and layout.AP033, 55 -
Emerson Cooper-Atkins 20900 Test Equipment
29.01.2026Maintenance instructions for the Emerson Cooper-Atkins 20900 Test Equipment. The document provides guidance on safety and product specifications, repair references, support details.Cooper-Atkins 20900, 19 -
SENTRONIC M-SYSTEM Mini-M Series Test Equipment
17.12.2025Device maintenance guide for the SENTRONIC M-SYSTEM Mini-M Series Test Equipment. This guide elaborates on device features and diagnostic information, compatibility information, calibration steps, operating guidelines.M-SYSTEM Mini-M Series, 4
Have some Questions about Amprobe GP-2 GeoTest Device?
Get valuable and actionable advices from other Amprobe GP-2 GeoTest device users. Describe your problem or question, regarding the using of GP-2 GeoTest, in as much detail as possible, and other users will be able to answer you.