Advanced Navigation ILU Reference Manual
Text of the manual
ILU Reference Manual
Page 1 of 30
Version 1.2
14/12/2016
Table of Contents
1 Revision History.........................................................................................................2
2 Firmware Changelog..................................................................................................3
3 Hardware Changelog.................................................................................................4
4 Introduction...............................................................................................................5
5 Quick Start Guide......................................................................................................6
5.1 Default username and password........................................................................6
5.2 WiFi Access Point................................................................................................6
5.3 Ethernet Port 1...................................................................................................6
5.4 Ethernet Port 2...................................................................................................7
6 Part Numbers and Ordering Options..........................................................................8
6.1 Standalone Unit..................................................................................................8
6.2 Accessories.........................................................................................................8
7 Specifications............................................................................................................9
7.1 Mechanical Drawings..........................................................................................9
7.2 Interfaces Specifications...................................................................................10
7.3 Protocols Specifications....................................................................................10
7.4 Hardware Specifications...................................................................................11
7.5 Electrical Specifications....................................................................................11
7.6 Connectors Pin-out...........................................................................................12
7.6.1 Power Connector.......................................................................................12
7.6.2 INS Connector............................................................................................13
7.6.3 IO Connector.............................................................................................14
7.6.3.1 Differential or Single Ended Encoders................................................15
7.6.3.2 5 Volt Output......................................................................................15
7.6.4 COM Connectors........................................................................................15
7.6.4.1 RS422 Mode.......................................................................................16
7.7 ILU to ODU Cable..............................................................................................16
7.8 ILU to Glenair Cable..........................................................................................17
8 Operation.................................................................................................................19
8.1 Power On..........................................................................................................19
8.2 Connection.......................................................................................................19
8.3 Web Interface...................................................................................................19
8.3.1 Status Indicators........................................................................................20
8.3.1.1 Time Synchronisation Indicator..........................................................20
8.3.2 Menus........................................................................................................21
8.3.2.1 Views Menu........................................................................................21
8.3.2.2 Device Configuration Menu................................................................21
8.3.2.3 ILU Configuration Menu......................................................................22
8.3.2.4 Tools Menu..........................................................................................22
8.4 Data Input/Output Configuration Example........................................................23
8.5 Logging Data....................................................................................................25
8.5.1 File Naming................................................................................................25
8.5.2 Logging Control.........................................................................................25
8.5.3 Logging Configuration...............................................................................26
8.5.4 Managing Log Files....................................................................................27
8.6 NTRIP Client......................................................................................................28
8.7 Connecting with Spatial Manager.....................................................................29
ILU Reference Manual
Page 2 of 30
Version 1.2
14/12/2016
1
Revision History
Version
Date
Changes
1.2
14/12/2016
Updated firmware changelog, section 2
Updated IP address for WiFi access, section 5.2
Updated IP address for Ethernet port 2 access, section 5.4
1.1
08/06/2016
Corrected error in part numbers description, section 6
1.0
17/09/2015
Initial Release
Table 1: Revision history
ILU Reference Manual
Page 3 of 30
Version 1.2
14/12/2016
2
Firmware Changelog
Version
Date
Changes
1.81
14/12/2016
IP subnets updated to less commonly used subnets
Log file size split
Altitude changed to 3 decimal places in NMEA strings
Bug fix for memory leak on NTRIP failed connections
Improvements to NTP and PTP timing
Bug fix for raw sensors display not updating when
overrange occurs
Added option to disable WiFi
Internal bugfixes and stability improvements
1.0
17/09/2015
Initial Release
0.5
11/05/2015
Beta Release
Table 2: Firmware changelog
ILU Reference Manual
Page 4 of 30
Version 1.2
14/12/2016
3
Hardware Changelog
Version
Date
Changes
1.0
24/02/2015
Initial Release
Table 3: Hardware changelog
ILU Reference Manual
Page 5 of 30
Version 1.2
14/12/2016
4
Introduction
The ILU (Interface and Logging Unit) is a device server that interfaces to any of
Advanced Navigation's systems and provides data logging, a web interface, a time
synchronisation server and a wide variety of different industry standard data
input/output options.
The ILU has no accompanying software and is fully managed through its web user
interface available over WiFi and the ethernet ports.
If you have any questions please contact [email protected].
ILU Reference Manual
Page 6 of 30
Version 1.2
14/12/2016
5
Quick Start Guide
Connect to the ILU web interface through the WiFi, Ethernet port 1 or Ethernet port 2
using the instructions below.
5.1
Default username and password
The web interface is protected by a username and password. The factory default
username and password is listed below.
Username
Password
admin
password
Table 4: Default username and password
5.2
WiFi Access Point
The factory default WiFi SSID and password are listed below.
Access Point SSID
Access Point Password
an-ilu
password
Table 5: WiFi access point default settings
To connect to the WiFi access point follow the steps below.
1. Power on the ILU and wait 30 seconds for it to boot.
2. Connect to the ILU WiFi access point using the SSID and password listed above
in Table 5.
3. Open a web browser and type in the address http://10.146.102.1
4. When prompted enter the default username and password listed in section 5.1.
5.3
Ethernet Port 1
By default Ethernet port 1 runs a DHCP client which means this port is intended to be
connected to a router. To connect over Ethernet port 1 follow the steps below.
1. Connect ILU Ethernet port 1 to your router with a standard Ethernet cable.
2. Power on the ILU.
3. Install zeroconf (Apple Bonjour) from one of the links below.
https://www.advancednavigation.com.au/Bonjour.msi (32-bit installer)
https://www.advancednavigation.com.au/Bonjour64.msi (64-bit installer)
4. Open a web browser and type in the address http://an-ilu.local
5. When prompted enter the default username and password listed in section 5.1.
ILU Reference Manual
Page 7 of 30
Version 1.2
14/12/2016
5.4
Ethernet Port 2
By default Ethernet port 2 runs a DHCP server which means this port is intended to be
connected directly to your computer. To connect over Ethernet port 2 follow the steps
below.
1. Connect ILU Ethernet port 2 directly to your computer with a standard Ethernet
cable. A crossover cable is not required as the port has automatic crossover.
2. Power on the ILU.
3. Open a web browser and type in the address http://10.146.101.1
4. When prompted enter the default username and password listed in section 5.1.
ILU Reference Manual
Page 8 of 30
Version 1.2
14/12/2016
6
Part Numbers and Ordering Options
6.1
Standalone Unit
Part Number
Description
Notes
ILU
Interface and
Logging Unit
Interface and Logging Unit
No cables included.
Requires either ILU-ACDC-PWR or ILU-CAR-
12V power cable.
Requires additional cable to interface to
other systems.
Table 6: Standalone unit part numbers
6.2
Accessories
Part Number
Description
Notes
ILU-CBL-ODU
ILU cable for
Spatial, Spatial
Dual or Orientus
2 metre ILU to ODU cable for Spatial,
Spatial Dual or Orientus. Supplies power.
See section 7.7.
ILU-CBL-FOG
ILU cable for
Spatial FOG or
Spatial FOG Dual
2 metre ILU to Glenair cable for Spatial
FOG or Spatial FOG Dual. Supplies power.
See section 7.8.
ILU-CAR-12V
12V car cigarette
lighter power
supply for ILU
3 metre car cigarette lighter to ILU power
connector cable.
ILU-ACDC-PWR
100-240V AC
power supply for
ILU
100 – 240V AC IEC power supply for ILU.
1.2 metre cable length. Included with
standalone unit.
S40B0C-P02MJG0-50GS ILU power
connector
unterminated
Unterminated ILU power connector.
Solder bucket terminals suit 20 to 26AWG
wire.
Gland fits 5mm diameter round cable.
Table 7: Accessories part numbers
ILU Reference Manual
Page 9 of 30
Version 1.2
14/12/2016
7
Specifications
7.1
Mechanical Drawings
Illustration 1: Mechanical drawings of interface and logging unit
ILU Reference Manual
Page 10 of 30
Version 1.2
14/12/2016
7.2
Interfaces Specifications
Parameter
Value
RS232/RS422 Ports
6
Baud Rates
1200 to 1M baud
Ethernet Ports
2
Ethernet Features
Gigabit
Hardware PTP
CAN Ports
1
GPIO Pins
8
Encoder Inputs
2 Differential Quadrature
2 Standard Quadrature
4 Frequency
WiFi
802.11b
802.11g
802.11n
Table 8: Interfaces specifications
7.3
Protocols Specifications
Parameter
Value
Supported Protocols
NMEA 0183
NMEA 2000
TSS
Simrad
Novatel
Trimble
Hemisphere
Topcon
Ashtech
IxSea
Applanix
Raw Binary (logging)
Raw ASCII (logging)
Supported Output Data Rates
Up to 1000 Hz
Logging Capacity
64GB (128GB option)
Simultaneous Logging
16 sources
Corrections
NTRIP Client
Table 9: Protocols specifications
ILU Reference Manual
Page 11 of 30
Version 1.2
14/12/2016
7.4
Hardware Specifications
Parameter
Value
Operating Voltage
9 to 36 V
Input Protection
-40 to 100 V
Power Consumption
3.5 Watts
Operating Temperature
-40 to 85 °C
Environmental Protection
IP68
MIL-STD-810G
Shock Limit
40 g
Dimensions
204x100x52 mm
Weight
550 g
Table 10: Hardware specifications
7.5
Electrical Specifications
Parameter
Minimum
Typical
Maximum
Power Supply
Input Supply Voltage
9 V
36 V
Input Protection Range
-40 V
100 V
RS232
Tx Voltage Low
-5.4 V
-5 V
Tx Voltage High
5 V
5.4 V
Tx Short Circuit Current
±60 mA
Rx Threshold Low
0.6 V
1.2 V
Rx Threshold High
1.5 V
2.0 V
RS422
Tx Differential Output
1.5 V
Tx Short Circuit Current
±250 mA
Rx Differential Threshold
-0.2 V
-0.05 V
GPIO
Output Voltage Low
0 V
0.3 V
Output Voltage High
4.8 V
5 V
Output Current
5 mA
Input Voltage
-20 V
20 V
Input Threshold Low
1.5 V
Input Threshold High
3.5 V
ILU Reference Manual
Page 12 of 30
Version 1.2
14/12/2016
Parameter
Minimum
Typical
Maximum
1PPS Output
Output Voltage Low
0 V
0.1 V
Output Voltage High
2.4 V
3.3 V
Output Current
50 mA
Encoder Inputs
Input Voltage Range
-25 V
25 V
Input Threshold Low (Single Ended Input)
2.3 V
Input Threshold High (Single Ended Input)
2.7 V
Input Threshold (Differential Input)
-0.2 V
0.2 V
CAN
Input Voltage Range
-60 V
60 V
Differential Output Voltage (Dominant)
1.5 V
2.2 V
3.0 V
Differential Output Voltage (Recessive)
-0.5 V
0 V
0.05 V
Differential Input Voltage Threshold
0.5 V
0.9 V
Table 11: Electrical specifications
7.6
Connectors Pin-out
The ILU contains 11 different connectors on the back panel, please see Illustration 2.
The pin-out for these connectors is detailed below. Advanced Navigation stocks pre-
terminated cables for the power and INS connectors. The other 9 connectors are
industry standard with connectors and cables widely available.
7.6.1
Power Connector
The power connector is labelled “PWR” in Illustration 2. The socket is an ODU G80B0C-
P02LJG0-0000 and the mating connector is an ODU S40B0C-P02MJG0-50GS. Advanced
Navigation stocks a 100-240V power supply with this connector, a car cigarette lighter
power supply with this connector and the unterminated connector. Please see section
Illustration 2: ILU back panel connectors
ILU Reference Manual
Page 13 of 30
Version 1.2
14/12/2016
6.2 for ordering details. The pin-out is listed below.
Pin
Function
1
Ground
2
Power Supply
Table 12: Power connector pin allocation table
7.6.2
INS Connector
The INS connector is intended to be connected to an Advanced Navigation Spatial,
Spatial Dual, Spatial FOG or Spatial FOG Dual. It carries RS232 or RS422
communication, 1PPS for synchronisation (over GPIO 1) and also power for the unit
connected. The socket is an ODU G81B0C-P08LFG0-0000 and the mating connector is
an ODU S41B0C-P08MFG0-50GS. Advanced Navigation stocks two different pre-
terminated cable variants. One cable is for connection to Spatial, Spatial Dual or
Orientus, see section 7.7. The second cable is for connection to Spatial FOG or Spatial
FOG Dual, see section 7.8. Please see section 6.2 for ordering details. The connector
pin-out is listed below. The selection of RS232 or RS422 is software configurable.
Illustration 3: Power
connector socket pins
1
2
Illustration 4: INS connector
socket pins
ILU Reference Manual
Page 14 of 30
Version 1.2
14/12/2016
Pin
Function
1
Signal Ground
2
RS422 Rx(-)
3
RS422 Tx(-)
4
RS232 Rx / RS422 Rx(+)
5
RS232 Tx / RS422 Tx(+)
6
1PPS Input
7
Power Supply
8
Power Ground
Table 13: INS connector pin allocation table
7.6.3
IO Connector
The IO connector contains the GPIO, CAN and encoder signals. The socket is a
standard female D Sub HD 15 connector and the mating connector is a standard male
D Sub HD 15 connector. The connector pin-out is listed below.
Pin
Function
1
Encoder 1 (Phase A) (+)
2
Encoder 2 (Phase A) (+)
3
Encoder 1 (Phase B) (+)
4
Encoder 2 (Phase B) (+)
5
5 Volt Output, see section 7.6.3.2
6
Encoder 1 (Phase A) (-), see section 7.6.3.1
7
Encoder 2 (Phase A) (-), see section 7.6.3.1
8
Encoder 1 (Phase B) (-), see section 7.6.3.1
9
Encoder 2 (Phase B) (-), see section 7.6.3.1
10
Ground
Illustration 5: IO connector socket pins
ILU Reference Manual
Page 15 of 30
Version 1.2
14/12/2016
Pin
Function
11
GPIO 1
12
GPIO 2
13
CAN Hi
14
CAN Lo
15
Ground
Table 14: IO connector pin allocation table
7.6.3.1
Differential or Single Ended Encoders
Please note that the encoder inputs can be used as either differential or single ended
(non-differential). When using the pins as single ended the signal should be connected
to the (+) pins and the (-) pins should be left disconnected.
7.6.3.2
5 Volt Output
The 5 volt output is intended for powering encoders and other auxiliary equipment. It
is protected by a 400mA current limit.
7.6.4
COM Connectors
Each COM connector carries a standard RS232 or RS422 serial port. Each port can be
software configured to operate in RS232 mode or RS422 mode. The RS232 connector
is industry standard and compatible with third party equipment. The sockets are a
standard male D Sub 9 connector and the mating connector is a standard female D
Sub 9 connector. The connector pin-out is listed below.
Pin
Function
1
Not Connected
2
RS232 Rx / RS422 Rx (+)
3
RS232 Tx / RS422 Tx (+)
Illustration 6: COM connectors socket pins
ILU Reference Manual
Page 16 of 30
Version 1.2
14/12/2016
Pin
Function
4
Not Connected
5
Ground
6
Not Connected
7
RS422 Tx (-)
8
RS422 Rx (-)
9
Not Connected
Table 15: COM connectors pin allocation table
7.6.4.1
RS422 Mode
When operating the port in RS422 mode please be aware that unlike RS232 there is no
industry standard pin allocation for RS422 and there is variation across different
manufacturers RS422 pin allocation so adaptors may be required when connecting to
some third party RS422 equipment.
7.7
ILU to ODU Cable
The ILU to ODU cable is required to connect a Spatial, Spatial Dual or Orientus device
to the ILU. Please see section 6.2 for ordering information.
Illustration 7: ILU to ODU cable
ILU Reference Manual
Page 17 of 30
Version 1.2
14/12/2016
ODU 9 Pin
Colour
Function
ODU 8 Pin
1
Black
Signal Ground
1
2
Brown
Power Supply
7
3
White
ILU 1PPS Input (GPIO 1)
6
4
Green
GPIO2
5
Red
RS232 Tx / RS422 Tx (+)
5
6
Orange
RS232 Rx / RS422 Rx (+)
4
7
Yellow
RS422 Tx (-)
3
8
Blue
RS422 Rx (-)
2
9
Pink
Power Ground
8
Table 16: ILU to ODU cable pin allocation table
7.8
ILU to Glenair Cable
The ILU to Glenair cable is required to connect a Spatial FOG or Spatial FOG Dual
device to the ILU. Please see section 6.2 for ordering information.
Illustration 8: ILU to Glenair cable
ILU Reference Manual
Page 18 of 30
Version 1.2
14/12/2016
Glenair Pin
Colour
Function
ODU 8 Pin
1
Black
ILU 1PPS Input (GPIO 1)
6
2
Brown
GPIO 2
3
Red
Signal Ground
1
4
Orange
Power Ground
8
5
Yellow
Power Supply
7
6
Green
RS232 Rx / RS422 Rx (+)
4
7
Blue
RS422 Rx (-)
2
8
Violet
RS232 Tx / RS422 Tx (+)
5
9
Grey
RS422 Tx (-)
3
10
White
Auxiliary RS232 Tx
11
White/Black
Auxiliary RS232 Rx
12
White/Brown
GNSS RS232 Rx
13
White/Red
GNSS RS232 Tx
Table 17: ILU to Glenair cable pin allocation table
ILU Reference Manual
Page 19 of 30
Version 1.2
14/12/2016
8
Operation
8.1
Power On
The ILU powers on as soon as power is connected to it. To power it off hold the power
button on the front panel for 4 seconds or disconnect the power lead.
8.2
Connection
Connection to the ILU web interface can be made over WiFi, Ethernet port 1 or
Ethernet port 2. Please follow the instructions of the quick start guide in section 5 to
establish a connection with the ILU and access the web interface.
8.3
Web Interface
The ILU user interface is accessed through a web browser. Upon logging into the ILU
you will see the home page shown below in Illustration 9.
ILU Reference Manual
Page 20 of 30
Version 1.2
14/12/2016
8.3.1
Status Indicators
The three status indicators provide the full status of the system and the device
connected to it.
8.3.1.1
Time Synchronisation Indicator
Every time the ILU powers off its time becomes invalid. On power up the system will
acquire time either through the network (NTP or PTP), the navigation device it is
connected to or a peripheral device (i.e. NMEA). There are three levels of time
synchronisation on the ILU.
Illustration 9: Screenshot of ILU home page with features labelled
ILU Reference Manual
Page 21 of 30
Version 1.2
14/12/2016
Time Status
Time Accuracy
Requirement
Time Invalid
Invalid
Coarse Time
< 250 ms
Not disciplined
INS GNSS Fix or
Network Time Protocol or
NMEA
Fine Time
< 100 ns
Disciplined
INS 1PPS Input or
Precision Time Protocol
Table 18: Time accuracy levels
With a Spatial, Spatial Dual, Spatial FOG or Spatial FOG Dual connected the time will
automatically be initialised to fine time about a minute after the system has a GNSS
fix.
8.3.2
Menus
The web interface and menus dynamically reconfigure based upon the device
connected to the INS port. The menus shown below are based on a connection to a
Spatial device.
8.3.2.1
Views Menu
The views menu provides a number of different graphical data displays for viewing
data from the connected Advanced Navigation device.
8.3.2.2
Device Configuration Menu
The device configuration menu provides several dialogues for configuration of the
connected Advanced Navigation device.
Illustration 10: Screenshot of views menu
ILU Reference Manual
Page 22 of 30
Version 1.2
14/12/2016
8.3.2.3
ILU Configuration Menu
The ILU configuration menu contains all the different dialogues for configuration of the
ILU itself.
8.3.2.4
Tools Menu
The tools menu provides dialogues for updating the connected device firmware, the
ILU firmware and a file manager page for log files.
Illustration 11: Screenshot of device configuration menu
Illustration 12: Screenshot of ILU configuration menu
ILU Reference Manual
Page 23 of 30
Version 1.2
14/12/2016
8.4
Data Input/Output Configuration Example
1. Under the ILU Configuration menu, open the Data Streams page.
2. The data streams page provides the ability to configure all of the input and
output devices of the ILU.
Illustration 13: Screenshot of ILU tools menu
Illustration 14: Data
streams in menu
ILU Reference Manual
Page 24 of 30
Version 1.2
14/12/2016
3. Click on the applicable port. In this example we will select the COM1 serial port.
You will be presented with the page shown below.
4. In this example we will configure the port output for NMEA timing (GPZDA) and
navigation data (GPRMC). Select NMEA as the output function and the NMEA
output options appear.
Illustration 15: Data streams page
Illustration 16: COM1 port configuration page
ILU Reference Manual
Page 25 of 30
Version 1.2
14/12/2016
5. We want timing at 1Hz and navigation at 10Hz so we set GPZDA to 1 and
GPRMC to 10. Click save and the configuration is complete and active
immediately.
8.5
Logging Data
The ILU can log data from many different sources simultaneously. By default the ILU is
set to automatically log data from the INS system connected to it. Logging starts
automatically at power on if it is enabled.
8.5.1
File Naming
When the ILU has valid time from a network or the connected INS device the log file
name will consist of the date and time the log file was started. For example the log file
COM1_15-09-12_15-24-02.anpp would have been started at 3:24:02pm on the 12th
September 2015.
When the ILU has invalid time the log file names will consist of a number. i.e.
COM1_0001.bin. If the ILU initialises its time while it is recording a log file it will
rename the log file to the correct date time at which it was started.
8.5.2
Logging Control
The logging indicator on the front of the unit indicates whether the unit is currently
logging data. The log button on the front of the unit can be used to start and stop
logging at any time, please see Illustration 18. When the button is pressed to stop
Illustration 17: Port configuration page with NMEA output
options displayed
ILU Reference Manual
Page 26 of 30
Version 1.2
14/12/2016
logging the current log files will be closed and logging will cease. When the button is
pressed again new log files will be started. There is no upper limit on a single log file
size. The only limit is that logging will stop when the system runs out of space.
8.5.3
Logging Configuration
1. Under the ILU Configuration menu, open the Data Streams page.
2. The data streams page shows a list of all the ports and the far right column
indicates whether logging is enabled on each port. Click on the port you would
like to enable logging on.
Illustration 18: Logging button on the front panel of the ILU
Illustration 19: Data streams
in menu
ILU Reference Manual
Page 27 of 30
Version 1.2
14/12/2016
3. Set logging to enabled and click save.
8.5.4
Managing Log Files
1. In the Tools menu, open the Log Files page.
Illustration 20: Data streams page
Illustration 21: Port configuration page
ILU Reference Manual
Page 28 of 30
Version 1.2
14/12/2016
2. The log files page displays all the log files currently on the device. The log files
currently being logged are highlighted in green. Click on the file name of a log
file to download it.
8.6
NTRIP Client
When the ILU is connected to a network that has access to the internet, it can stream
differential corrections from an NTRIP network corrections service to the INS device to
offer higher accuracy differential or RTK positioning.
1. In the ILU Configuration menu, open the NTRIP page.
2. Enter the details provided by your NTRIP network corrections service provider.
Illustration 22: Log files in
menu
Illustration 23: Log Files page
ILU Reference Manual
Page 29 of 30
Version 1.2
14/12/2016
8.7
Connecting with Spatial Manager
Spatial Manager can easily connect to the connected device through the ILU over a
network connection. Please follow the steps below to connect.
1. In the Tools menu, click on the Network Connect dialogue.
2. Type in the address used to connect to the ILU web page and the port 16718
and press connect.
Illustration 24: NTRIP configuration page
Illustration 25: Spatial Manager ILU connection
ILU Reference Manual
Page 30 of 30
Version 1.2
14/12/2016
Information in this document is provided solely in connection with Advanced Navigation products. Advanced Navigation
reserves the right to make changes, corrections, modifications or improvements, to this document, and the products
and services described herein at any time, without notice.
All Advanced Navigation products are sold pursuant to Advanced Navigation’s terms and conditions of sale.
Purchasers are solely responsible for the choice, selection and use of the Advanced Navigation products and services
described herein, and Advanced Navigation assumes no liability whatsoever relating to the choice, selection or use of
the Advanced Navigation products and services described herein.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted under this
document. If any part of this document refers to any third party products or services it shall not be deemed a license
grant by Advanced Navigation for the use of such third party products or services, or any intellectual property
contained therein or considered as a warranty covering the use in any manner whatsoever of such
third party products or services or any intellectual property contained therein.
UNLESS OTHERWISE SET FORTH IN ADVANCED NAVIGATION’S TERMS AND CONDITIONS OF SALE ADVANCED
NAVIGATION DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY WITH RESPECT TO THE USE AND/OR SALE OF ADVANCED
NAVIGATION PRODUCTS INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A
PARTICULAR PURPOSE (AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION), OR INFRINGEMENT OF ANY
PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT.
UNLESS EXPRESSLY APPROVED IN WRITING BY TWO AUTHORIZED ADVANCED NAVIGATION REPRESENTATIVES,
ADVANCED NAVIGATION PRODUCTS ARE NOT RECOMMENDED, AUTHORIZED OR WARRANTED FOR USE IN MILITARY, AIR
CRAFT, SPACE, LIFE SAVING, OR LIFE SUSTAINING APPLICATIONS, NOR IN PRODUCTS OR SYSTEMS WHERE FAILURE OR
MALFUNCTION MAY RESULT IN PERSONAL INJURY, DEATH, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE.
ADVANCED NAVIGATION PRODUCTS WHICH ARE NOT SPECIFIED AS "AUTOMOTIVE GRADE" MAY ONLY BE USED IN
AUTOMOTIVE APPLICATIONS AT USER’S OWN RISK.
Resale of Advanced Navigation products with provisions different from the statements and/or technical features set
forth in this document shall immediately void any warranty granted by Advanced Navigation for the Advanced
Navigation product or service described herein and shall not create or extend in any manner whatsoever, any
liability of Advanced Navigation.
Information in this document supersedes and replaces all information previously supplied.
© 2016 Advanced Navigation - All rights reserved