Acuity Controls nLIGHT Programming Instructions

Specifications

Brand: Acuity Controls
Category: Lantern
Model: nLIGHT (Programming Instructions)
File Type: PDF
File Size: —
Pages: 2

Read Online

Read the Acuity Controls nLIGHT Programming Instructions online using the built-in PDF viewer.

Text of the manual

1 of 2

Acuity Brands | One Lithonia Way Conyers, GA 30012 Phone: 800.535.2465 www.acuitycontrols.com © 2014-2015 Acuity Brands Lighting, Inc. All rights reserved. August 24, 2015 10:57 AM DOC# IN0012-005 Date Code 42115 1.800.535.2465 nLIGHT ENABLED DIGITAL LUMINAIRE PROGRAMMING INSTRUCTIONS 2 LUMEN COMPENSATION An algorithm that tracks the LED luminaire’s runtime and manages its light output to maintain constant lumen output over the system life. 3 IDLE TIME UNTIL DIM The length of time after last detected occupancy that the luminaire will reduce lighting level to Unoccupied Dim Level setting. 5 SWITCH TRACKING CHANNEL The channel on which the luminaire receives switch information. 6 FOLLOW PHOTOCELL MODE Directs the luminaire relative to a dimming photocell in its zone. 7 SECONDARY ZONE DIMMING OFFSET Percentage difference of unit’s dimming level from its connected zone’s primary dimming level (Function 6 must be enabled). 8 WALLPOD DIMMING ADJUSTMENTS Defines whether user dimming adjustments are maintained after lights are cycled, whether they revert to preset levels, or whether they temporarily disable a connected dimming photocell (until lights cycle). A-LEVEL FUNCTION DEFINITIONS ________________________________ 9 RESTORE FACTORY DEFAULTS Returns all functions to original settings. 19 DIMMING RATE The elapsed time over which changes to dimming levels initiated via global or local profile scenes are implemented. Note: dimming level changes initiated via global or local preset scenes are always immediate. 23 OCCUPIED BRIGHT LEVEL The percentage of the controllable dimming range up to which lights will rise when occupancy is detected or the luminaire is overridden on. Adjusting the dim level using a WallPod changes this setting. When set at 100%, light level will match High End Trim level. See function B31. 24 UNOCCUPIED DIM LEVEL The percentage of controllable dimming range to which lights manually or automatically dim to, once the Idle Time Until Dim timer expires. When set at 1%, light level will match Low End Trim level. See function B32. B-LEVEL FUNCTION DEFINITIONS ___________________________________________ 1 NAME UNIT w/ NUMBER Applies a number to the default name visible in SensorView (useful during commisioning) 2 MANUAL ON (SEMI-AUTO) GRACE PERIOD When in Manual On (Semi-Auto) mode (Function B-18), the time period after lights are automatically turned off that they can be reactivated with movement 3 PREDICTIVE EXIT TIME (valid for Predictive Off mode only) The time period after manually switching lights off for the occupant to leave the space 4 PREDICTIVE GRACE TIME (valid for Predictive Off mode only) The time period after the Predictive Exit Time that the sensor rescans the room for remaining occupants 11 OCCUPANCY TRACKING Indicates whether luminaire will react to occupancy information 12 OCCUPANCY TRACKING CHANNEL The channel on which luminaire receives occupancy information 13 PHOTOCELL TRACKING Indicates whether luminaire will react to photocell information 14 PHOTOCELL TRACKING CHANNEL The channel on which luminaire receives photocell information 15 SWITCH TRACKING Indicates whether luminaire will react to switch information 17 FORCED OVERRIDE Indicates whether luminaire is forced to max level or off 18 SPECIAL OPERATING MODE Unique defined behaviors of luminaire: NORMAL Operating Mode where occupancy sensors are capable of turning lights both on/off SEMI-AUTO (MANUAL ON) Special Mode that requires the occupant to manually turn the lights on, while having them turn off automatically by a sensor AUTO TO OVERRIDE ON Special Mode where lights are turned on initially by occupant detection but remain in the Override On state MANUAL ON TO FULL AUTO Special Mode that initially requires the occupant to manually turn on the lights, after which the sensor assumes full on/off control PREDICTIVE OFF When lights are switched off, sensor determines whether occupants remain or left the room, so as to leave the lights in either the Override Off or Auto On state MANUAL TO TIMED OVERRIDE ON Special Mode where lights are initially turned on manually but remain in the Override On state for a pre- determined period (Timed Override Delay) MANUAL TO NORMAL Special Mode where lights are initially turned on manually but remain in the Normal State (enabling auto- dimming) for a pre-determined period (Timed Override Delay) 22 MAINTAIN DIM LEVEL WHEN VACANT Prevents lights from turning fully off once in unoccupied state 23 SPECIAL SWITCH TRACKING MODE Defines unique behavior related to how luminaire responds to particular switch information. 29 OCCUPANCY EXPIRATION of MANUAL OFF When enabled, operation of device will revert from a push-button triggered override off state to Normal mode once the Occupancy Time Delay (adjustable via SensorView or push-button) expires. Not used with Manual On operating modes. 30 TIMED EXPIRATION of MANUAL OFF When enabled, operation of device will revert from a push-button triggered override off state to Normal mode once the Timed Override Delay (adjustable via SensorView) expires. Not used with Manual On operating modes. 31 HIGH END TRIM Maximum voltage level of the device’s dimming output. Commonly used for task tuning where absolute light level is not to be increased via a Wallpod or scene. When output is at high end trim, the reported control percentage will be 100%. Corresponding lumen output % is dependent on ballast/driver capabilities. Raising setting above factory default is not recommended as default is optimized to driver control range. 32 LOW END TRIM Minimum voltage level of the device’s active dimming range. Level can not be reduced via a WallPod or scene. Note, voltage level may go below this level when device is given an OFF command (for example when controlling LED drivers with sleep mode). When output is at low end trim, the reported control percentage will be 1%. Corresponding lumen output % is dependent on ballast/driver capabilities. Lowering setting below factory default is not recommended as default is optimized to driver control range. PLEASE READ ALL 4 STEPS BEFORE PROGRAMMING 1. Enter A-Level programming mode by pressing button the number of times as the desired function number from A-Level Detailed Function Tables below (e.g., press 5 times for function 5, Switch Tracking Channel). 2. The selected function’s current setting is indicated via LED flashes (e.g., 2 flashes for Switch Tracking - Channel 2). To change, proceed to step 3 before it repeats 3 times. 3. While the sensor flashes back current setting, press the button the number of times for the new desired setting as indicated in the detailed table (e.g., press 3 times for Switch Tracking - Channel 3). Sensor flashes new setting as confirmation. 4. Programming mode exits automatically when setting sequence flashes back 3 times without interruption. A-LEVEL PROGRAMMING INSTRUCTIONS __________________________________ PROGRAMMING FUNCTIONS _____________________________________________________ A-LEVEL FUNCTIONS 2 Lumen Compensation 3 Idle Time Until Dim 5 Switch Tracking Channel 6 Follow Photocell Mode 7 Secondary Zone Dimming Offset 8 WallPod Dimming Adjustments 9 Restore Factory Defaults 19 Dimming Rate 23 Occupied Bright Level 24 Unoccupied Dim Level B-LEVEL FUNCTIONS 1 Name Unit w/ Number 2 Manual On (Semi-Auto) Grace Period 3 Predictive Exit Time 4 Predictive Grace Time 11 Occupancy Tracking 12 Occupancy Tracking Channel 13 Photocell Tracking 14 Photocell Tracking Channel 15 Switch Tracking 17 Forced Override 18 Special Operating Mode 22 Maintain Dim Level When Vacant 23 Special Switch Tracking Mode 29 Occupancy Expiration of Manual Off 30 Timed Expiration of Manual Off 31 High End Trim 32 Low End Trim

2 of 2

Acuity Brands | One Lithonia Way Conyers, GA 30012 Phone: 800.535.2465 www.acuitycontrols.com © 2014-2015 Acuity Brands Lighting, Inc. All rights reserved. August 24, 2015 10:57 AM PLEASE READ ALL 4 STEPS BEFORE PROGRAMMING 1. Enter B-Level programming mode by holding down button until status LED flashes rapidly, release, hold down until rapid flash again, release, then immediately enter programming function as described in step 2. 2. Enter a programming function by pressing button the number of times as the desired function number from the B-Level Detailed Function Tables below (e.g., press twice for function 2, Semi- Auto Grace Period). 3. Staus LED will flash back the selected function’s current setting (e.g., 3 flashes for 15 sec). To change setting, proceed to step 3 before flash back sequence repeats 3 times. To exit the current function or to change to a different function, wait for sequence to repeat 3 times and return to step 1. 4. Press button the number of times indicated in the particular function’s detailed table for the new desired setting (e.g., press 1 time for 0 sec). As confirmation of setting change, status LED flashes back the new setting 3 times before exiting. INSTALLATION INSTRUCTIONS NOTE: For information on additional advanced settings, including resetting unit to factory defaults, contact: Technical Support: 1.800.535.2465 nPS 80 EZ B-LEVEL PROGRAMMING INSTRUCTIONS _______________________________ B-LEVEL DETAILED FUNCTION TABLES ____________________________ *Indicates factory default unless dependent on model number. ** Setting precision of 0.1V is available via SensorView. Device status LED blinks out current value rounded to nearest selection above. 1 = Name Unit w/ Number 1 1 3 3 5 5 7 7 9 9 2 2 4 4 6 6 8 8 10 Unassigned* 2 = Manual On (Semi-Auto) Grace Period 1 0 sec 3 15 sec* 3 = Predictive Exit Time 1 5 sec 3 7 sec 5 9 sec 7 15 sec 9 30 sec 2 6 sec 4 8 sec 6 10 sec* 8 20 sec 4 = Predictive Grace Time 1 0 sec 3 10 sec 5 30 sec 7 50 sec 2 5 sec* 4 20 sec 6 40 sec 8 60 sec 11 = Occupancy Tracking 1 Disable 2 Enable* 12 = Occupancy Tracking Channel 1 - 16 (e.g., 1 = Channel 1*; 2 = Channel 2; etc.) 13 = Photocell Tracking 1 Disable 2 Enable* 14 = Photocell Tracking Channel 1 - 16 (e.g., 1 = Channel 1*; 2 = Channel 2; etc.) 15 = Switch Tracking 1 Disable 2 Enable* 17 = Forced Override 1 Disabled (not forced)* 2 Override On 3 Override Off 18 = Special Operating Mode 1 Normal* 5 Predictive Off 2 Manual On 6 Manual to Override On 3 Auto to Override On 7 Manual to Normal 4 Manual to Full Auto 22 = Maintain Dim Level When Vacant 1 No* 2 Yes 23 = Special Switch Tracking Mode 1 Disable* 2 Ignore Offs 3 Ignore Ons 4 Ignore Ons & Offs 29 = Occupancy Expiration of Manual Off 1 Disabled* 2 Enabled 30 = Timed Expiration of Manual Off 1 Disabled* 2 Enabled 31 = High End Trim** 1 0.7V 3 2V 5 4V 7 6V 9 8V 11 10V 2 1V 4 3V 6 5V 8 7V 10 9V 32 = Low End Trim** 1 0.7V 3 2V 5 4V 7 6V 9 8V 11 10V 2 1V 4 3V 6 5V 8 7V 10 9V • Mount through a ½” knockout in any junction box or luminaire. Secure with lock nut. • Following above wiring diagram, connect wires to line voltage feed(s), neutral(s), and load. • Connect low voltage violet and gray dimming wires to 0-10 VDC driver leads and green wire to an approved ground connection. Note wires have 600V rated insula- tion. • Interconnect unit (via RJ-45 ports) with other nLight devices in lighting zone using CAT-5e cables. BUTTON LED RJ-45 PORTS *Indicates Factory Default A-LEVEL DETAILED FUNCTION TABLES ____________________________________________ 2 = Lumen Compensation 1 Disabled (n100) 2 Enabled (n80) 3 = Idle Time Until Dim 1 30 sec 3 5 min 5 10 min 7 15 min 9 20 min 2 2.5 min 4 7.5* min 6 12.5 min 8 17.5 min 5 = Switch Tracking Channel 1 - 16 (e.g., 1 = Channel 1*; 2 = Channel 2; etc.) 6 = Follow Photocell Mode 1 Disable* 2 Enabled (Neg) 3 Enabled (Pos/Neg) 7 = Secondary Zone Dimming Offset 1 -100% 5 -60% 9 -20% 13 20% 17 60% 21 100% 2 -90% 6 -50% 10 -10% 14 30% 18 70% 3 -80% 7 -40% 11 0% * 15 40% 19 80% 4 -70% 8 -30% 12 10% 16 50% 20 90% 8 = WallPod Dimming Adjustments 1 Permanent* 2 Temporary 3 Photocell Temp. Override 9 = Restore Factory Defaults 1 Maintain Current* 2 Restore Defaults 19 = Dimming Rate 1 5 min 2 15 sec 3 5 sec* 4 2 sec 5 Instant 23 = Occupied Bright Level 1 1% 3 20% 5 40% 7 60% 9 80% 11 100%* 2 10% 4 30% 6 50% 8 70% 10 90% 24 = Unoccupied Dim Level 1 1%* 3 20% 5 40% 7 60% 9 80% 11 100% 2 10% 4 30% 6 50% 8 70% 10 90%

Other Lantern Manuals