Battant de fenêtre

Raam Battente 120 51 18 3 Fensterrahmen Frame Cadre Kozijn Telaio Abb./fg./ schéma/ afb./ill. 1 Abb./fg./ schéma/ afb./ill. 2 FAS FTS FTS FAS FAS FAS FAS FTS FTS 48 28 max. 29 Abb./fg./schéma/afb./ill. 3 4 2 3 6 8 1 5 7 G These instructions are organised in the following sections: I. General instructions II. Possible uses III. Pack contents IV. Tools V. Installation instructions VI. Operation I. General instructions The window universal lock FTS 106 is recognised as complying with the strict test requirements of DIN 18104-1 and VdS 2536. FTS 106 is certifed by DIN Certco as “BURGLAR RETARDANT DIN tested”. FTS 106 ofers additional protection from unauthorised intruders in your rooms. DIN 18104-1 recommends that an additional security device should be ftted on the left and right for every meter in height (per window). The police and insurance companies also give the same recommendation. Optimum protection can be achieved by proceeding according to these installation and operation instructions. To prevent the risk of over- tightening, the fastening screws should be screwed in using a suitable tool and tightened by hand. Only use ABUS fastening material. The manufacturer does not assume any liability for possible injuries or damages caused during installation and/or by incorrect handling! II. Possible uses FTS 106 is mounted on the handle side of the window or French door and is suitable for all common windows/French doors opening to the inside with turn or turn-and-tilt hardware (fg. 2). The lock can be ftted to wood, PVC or aluminium. The windows/French doors can open to the right or left. FTS 106 is always ftted on the inside, with the lock case on the casement and the striking plate on the frame. In poor fxture conditions (soft or hollow or foam base and PVC windows with and without metal inlay and wooden windows) and/or good possibilities for intrusion from the outside, more security devices and additional fastenings should be used (composite mortar or fxing bolts). If the frame itself is too weak for sensible retroftting, it may be necessary for example to reinforce the frame. To do so, please use the ABUS fxing bolt BA or alternatively for PVC frames, the ABUS fastening set IM 100. For IM 100 you need a suitable composite mortar, e.g. Fischer FIS VS 150C or similar. ABUS BA and ABUS IM 100 are available from retail stores together with composite mortar. The ABUS products (FAS) shown in fg. 2 are also available from retail stores. III. Pack contents (fg. 3) 1. 1 lock case 2. 1 striking plate 3. 1 screw-on strip 4. 1 cover cap for lock case 5. 1 cover cap for locking case 6. 2 wedge-shaped washers 7. 1 set of spacers for the frame strip 1x1, 2, 4, 5 mm each 8. Screws: 8 each 5.5 x 60 mm 2 each 4.2 x 16 mm 2 each 4.2 x 9.5 mm 1 each M6 x 35 mm 3 each M6 x 25 mm IV. Tools Phillips screwdriver Slotted recess screwdriver Drill Saw, fle for shortening the screws, possibly vice Hex key, width across fats 4 for screws Ø in wood and PVC without metal inlay drill bit Ø in aluminium and PVC with metal inlay drill bit Ø 4.0 mm 3.0 mm 4.5 mm 3.0 mm 5.5 mm 4.2 mm Drilling table G ABUS Installation and operation instructions for ABUS universal window lock FTS 106

Unterlagen für Höhenausgleich

Spacers Entretoises Opvulplaatjes Spessori da livellamento Rahmen Frame Cadre Kozijn Telaio 3 mm Tür bzw. Fenster Door/Window Fenêtre Deur/Raam Porta risp. Finestra 2 mm Schlosskasten Lock case Boîtier Slotkast Cassa della serratura Schließkasten Locking case Gâche Sluitkast Scatola della serratura Falzhöhe Rebate height Recouvrement Opdekmaat Altezza d’incassatura 0–29 mm F 2 mm C B B C A A C2 D C1 D 3 mm E2 E1 E3 G V. Installation instructions: • Before installation, please check the setting of the window or French door. • If necessary, readjust the fttings so that the window (French door) opens and closes perfectly. • Also check whether your window/French door complies with the minimum dimensions shown in fg. 1. • The depths of the drilled holes and screw lengths must be adjusted to the local conditions. • Avoid the drill or screws from coming out at the back! Possibly work with drill stopper or shorten the existing screws. • When drilling, do not damage any moving parts, seals or glass panes. Installation: Fitting the lock case: 1. Screw on the knob supplied loose through hole “F” using the Phillips screwdriver (fg. 5a). The screw is already in the lock case (1). For DIN left (fg. 5c), for DIN right (fg. 5b). 2. Adjusting the personal code: The number combination of knob is set to 0-0-0 in the factory. Adjust the personal code as follows: a) In the setting 0-0-0, hold the side pin in. b) Adjust your personal code. c) Release the side pin again, the new code is now adjuste. We recommend that you note the code and keep the note in a safe place. ABUS cannot tell what the secret code is. 3. Remove the cover cap (4) from the lock case (1) from below by pressing on the catch points (fg. 6). Undo the locking bolt. 4. Hold the lock case (1) in the required position against the window casement or door, at a distance of 2 mm to the edge (fg. 7). 5. Mark and pre-drill hole position A and B (for PVC windows and doors also C) (fg. 8 and drilling table). 6. Screw on lock case (1). For holes A (depending on rebate height), use screws 4.2 x 16 mm or 4.2 x 9.5 mm (use screwdriver with magnetic tip). Holes B (C) screws 5.5 x 60 mm. Fitting the locking case: The lock case (1) and striking plate (2) must be on the same level (fg. 4). To compensate for the difering rebate heights, the striking plate (2) is lined, using the screw-on strip (3) and/or the spacers (7). Rebate height: from 14 mm [with screw-on strip (3) and possibly shims (7)]. 1. Hold the screw-on strip (14 mm high) on the same level and at a parallel distance of 3 mm to the lock case (1) (fg. 9). Ensure that the screw-on strip (3) is in the right position. 2. Mark and pre-drill bore holes C1 and C2 (fg. 10 and drilling table). 3. Line screw-on strip (3) with spacers (7) if necessary (rebate height larger than 14 mm). Screw tight with screws 5.5 x 60 mm. 4. Drill in the middle through the slanting screw holes D at the same angle to the wall (see drilling table). If this is not possible, drill vertically. Then place the two wedge-shaped washers (6) in holes D. 5. Screw 2 more screws 5.5 x 60 mm into holes D. 6. Remove the cover cap (5) from the striking plate (2) from below by pressing on the catch points (fg. 11). 7. Screw striking plate (2) to screw-on strip with 3 screws M6 x 25 mm. Check function: Locking bolt must run freely into the striking plate (2) when closing. 8. Press on both cover caps. Rebate height: 0 to 13 mm (possibly with shims). 1. Remove the cover cap (5) from the striking plate (2) from below by pressing on the catch points (fg. 11). 2. Hold striking plate (2) centrally on the same level and at a parallel distance of 3 mm to the lock case (1) (fg. 12). 3. Mark and pre-drill holes position E1 to E3 (Fig. 13) (see drilling table). 4. Line striking plate (2) with spacers (7) if necessary and screw tight with 3 screws 5.5 x 60 mm. Check function: Locking bolt must run freely into the striking plate (2) when closing. 5. Press on both cover caps. VI. Operation FTS 106 can be locked without a key by turning the knob (possibly adjust code). To open, enter the number combination – your personally adjusted code number – and turn the knob back. The number wheels should be changed again after locking and also after opening unintentionally.

Other Locks Manuals