ABB COMMANDER 1900 Series Programming Manual

Text of the manual

COMMANDER 1900 Series

Circular Chart Recorders COMMANDER 1900 100.3 dEG F 200.5 70.5

Clarification of an instruction or additional information.

Information. Further reference for more detailed information or technical details. Although Warning hazards are related to personal injury, and Caution hazards are associated with equipment or property damage, it must be understood that operation of damaged equipment could, under certain operational conditions, result in degraded process system performance leading to personal injury or death. Therefore, comply fully with all Warning and Caution notices. Information in this manual is intended only to assist our customers in the efficient operation of our equipment. Use of this manual for any other purpose is specifically prohibited and its contents are not to be reproduced in full or part without prior approval of Technical Communications Department, ABB Instrumentation. The Company ABB Instrumentation is an established world force in the design and manufacture of instrumentation for industrial process control, flow measurement, gas and liquid analysis and environmental applications. As a part of ABB, a world leader in process automation technology, we offer customers application expertise, service and support worldwide. We are committed to teamwork, high quality manufacturing, advanced technology and unrivalled service and support. The quality, accuracy and performance of the Company’s products result from over 100 years experience, combined with a continuous program of innovative design and development to incorporate the latest technology. The NAMAS Calibration Laboratory No. 0255(B) is just one of the ten flow calibration plants operated by the Company, and is indicative of ABB Instrumentation’s dedication to quality and accuracy. R E G I S T E R E D F I R M BS EN ISO 9001 St Neots, U.K. – Cert. No. Q5907 Stonehouse, U.K. – Cert. No. FM 21106 Stonehouse, U.K. – Cert. No. 0255 EN 29001 (ISO 9001) Lenno, Italy – Cert. No. 9/90A Use of Instructions Warning. An instruction that draws attention to the risk of injury or death. Caution. An instruction that draws attention to the risk of damage to the product, process or surroundings. Health and Safety To ensure that our products are safe and without risk to health, the following points must be noted: 1. The relevant sections of these instructions must be read carefully before proceeding. 2. Warning labels on containers and packages must be observed. 3. Installation, operation, maintenance and servicing must only be carried out by suitably trained personnel and in accordance with the information given. 4. Normal safety precautions must be taken to avoid the possibility of an accident occurring when operating in conditions of high pressure and/or temperature. 5. Chemicals must be stored away from heat, protected from temperature extremes and powders kept dry. Normal safe handling procedures must be used. 6. When disposing of chemicals ensure that no two chemicals are mixed. Safety advice concerning the use of the equipment described in this manual or any relevant hazard data sheets (where applicable) may be obtained from the Company address on the back cover, together with servicing and spares information.

INTRODUCTION ......................................................... 1

2 GENERAL PROGRAMMING ...................................... 2 2.1 Preparation for Changes to the Parameters ................................................. 2 2.2 Security System ............................................... 2 3 BASIC CONFIGURATION LEVEL.............................. 2 3.1 Set Up Input (Process Variable) ....................... 4 3.2 Set Up Pen Range/Event Source..................... 8 3.3 Set Up Chart .................................................... 9 3.4 Set Up Alarms ................................................ 10 3.5 Set Up Relay Output ...................................... 14 3.6 Set Up Digital Output ..................................... 16 3.7 Set Up Analog Output .................................... 18 3.8 Digital Inputs................................................... 20 3.9 Access Page................................................... 21 3.10 Scale Adjust ................................................... 22 4 ADVANCED CONFIGURATION LEVEL................... 25 4.1 Set Up Function Keys..................................... 25 4.2 Set Up Logic ................................................... 26 4.3 Set Up Pen Functions .................................... 28 5 CONNECTIONS & LINKS......................................... 29 The COMMANDER 1900 series of documentation is shown in Fig. 1.1. The Standard Manuals, including the specification sheet, are supplied with all instruments. The Supplementary Manuals supplied depend on the specification of the instrument. 1 INTRODUCTION A – Standard Manuals Part No. IM/C1900–INS INSTALLATION Product Identification Siting Mounting Electrical Connections Installation Record OPERATION Setting Up Displays & Controls Operating Level Simple Fault Finding Part No. IM/C1900–OGR PROGRAMMING SPECIFICATION SHT. Full Specification Part No. IM/C1900–PGR Part No. SS C1900 Flow Totalisation Ramp/Soak Profile Maths Functions Timer Functions Modbus (RTU) Serial Adaptors Serial Connections Programming Pages ASCII Tables Part No. IM/C1900–ADV Part No. IM/C1900–MOD ADVANCED SOFTWARE OPTIONS General Programming Basic Config. Level Advanced Config. Level Connections & Links B – Supplementary Manuals Fig. 1.1 COMMANDER 1900 Documentation

The programming procedures are used to make changes to

the operating parameter values and for scale adjustment – see Fig. 3.2. The programming of all channels is performed using faceplate 1 – see Fig. 3.1 When changing the input type it may be necessary to reposition the input selector links accordingly – see Section 5, CONNECTIONS & LINKS. 2.1 Preparation for Changes to the Parameters Ensure that the external alarm/control circuits are isolated if inadvertent operation during programming is undesirable. Any change to the operating parameters are implemented using the or switches – see Section 3 of the Operating Guide. Note. The instrument responds instantly to parameter changes which are saved automatically when leaving the current frame. 2.2 Security System A security system is used to prevent tampering with the programmed parameters by restricting access to programming levels, other than the OPERATOR LEVEL; all users have access to this level. A security password is used to give access to the programming pages. The password can be set to any value from 0 to 9999. The instrument is despatched with the password set to '0' – see Section 4.5 of Operating Guide. 3.1 Set Up Input (Process Variable) .............................. 4 • Input types • Linearization • Electrical ranges • Engineering ranges • Fault detection • Digital filtering 3.2 Set Up Pen Range ...................................................... 8 • Chart ranges • Event pen sources 3.3 Set Up Chart ............................................................ 9 • Chart duration (speed) • Chart stop function • Auto pen drop • Pen lift 3.4 Set Up Alarms .............................................................. 10 • Acknowledge type • Global alarm acknowledge • Alarm type • Trip/hysteresis/time hysteresis 3.5 Set Up Relay Output ................................................ 14 • Relay sources • Relay polarity 3.6 Set Up Digital Output .............................................. 16 • Digital output source • Digital output polarity 3.7 Set Up Analog Output ............................................. 18 • Retransmission sources • Retransmission ranges • Current output ranges 3.8 Digital Inputs .......................................................... 20 • Input polarity 3.9 Access Page .......................................................... 21 • Configurable password • Internal security link 3.10 Scale Adjust .......................................................... 22 • Process variable offset adjustment • Process variable span adjustment • Pen calibration • Mains filter • Pen Linearity Check Faceplate 1 Fig. 3.1 Location of Faceplate 1 2 GENERAL PROGRAMMING 3 BASIC CONFIGURATION LEVEL

BASIC CONFIGURATION LEVEL…

* These pages do not appear on the non-upgradeable version (1901J) Fig. 3.2 Basic Configuration Level SEtUP INPUt Set Up Input (PV) Input Type (PV) Temperature Units ENG–LO ____ dEC–Pt ____ rNG–HI _.__ Input Range High IntYP ____ SEtUP ALArMS Set Up Alarms Acknowledge Type SELECt __ CHArt ____ Chart Time Stop Chart Signal Select PV/Pen/Filter Scale Reset Offset Adjustment Cal. Pen At 100% Cal. Pen At 0% Select Alarm trIP ____ Trip Level Span Adjust Set Up Inputs Section 3.1 Page 4 Set Up Pen Range Section 3.2 Page 8 Set Up Alarms Section 3.4 Page 12 Setup Chart Section 3.3 Page 9 Scale Adjust Section 3.10 Page 23 UNItS ____ ENG–HI ____ Input Range Low FdLP-I _.__ Fault Detection Level Programmable Filter PrGFLt _.__ bSPd ____ Broken Sensor Drive rNG–LO _.__ HYSt ____ Hysteresis Select Pen Pen Range High Pen Range Low In Source SEtUP PENrNG Set Up Pen Range tYPE ____ Alarm Type ACKtYP ____ t–HYSt ____ Time Hysteresis Select Channel SELECt ____ SELECt ____ rESEt __ OFFSEt ____ SPAN ____ SEtPEN At100 Scale Adjust SCALE AdJUSt Set Up Chart SELECt ____ PEN–HI ____ PEN–LO ____ Out Source IN SrC ______ OUt.SrC ______ SEtUP CHArt CH–StP ______ Engineering High Decimal Point Engineering Low Linearizer Type LNtYP ____ ACKSrC ______ Alarm Ack Source Select Output Output Range High Output Range Low Output Source Set Up Analog Output* Section 3.7 Page 18 SELECt ____ Set Up Relay Output* Section 3.5 Page14 Select Relay SELECt ____ Relay Source Set Up Output SEt UP ANALOG Set Up Relay SEt UP rELAYS Retrans. Range Hi Retrans. Range Low SOUrCE ____ HI–OP ____ LO–OP ____ OP–SrC ____ rNG–HI ____ rNG–LO ____ Polarity POLrtY ____ ACCESS PAGE Access Page Access Page Section 3.9 Page 21 Configure Password C– PASS __ dIGtAL INPUtS Digital Inputs Digital Inputs* Section 3.8 Page 20 Polarity POLrtY ___ Select Digital I/P SELECt ____ SEtPEN At 0 Check Pen Cal. CHECK __._ Auto Pen Drop AUtdrP ___ Pen Lift Enable LIFt.EN ___ Pen Lift/Pen Status PENLFt ____ OPrtOr LEVEL bASIC CONFIG AdVNCd CONFIG Basic Config Advanced Config Operator Level Set Up Digital Output Section 3.6 Page 16 Select Output SELECt ____ Output Source Digital Outputs dIGtAL OUtPtS SOUrCE ____ Polarity POLrtY ____ Mains Filter FILtEr __ Hrt