ADCP-92-049 • Issue 1 • February 2004

1260345 Rev A Page 1 © 2004, ADC Telecommunications, Inc. OptEnet™ 1000 Mb/s Ethernet Media Converter Module User Manual INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 List of Changes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Trademark Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Related Publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Admonishments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 General Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 FCC Compliance Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 UL/CSA Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 NEBS Certification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1 PRODUCT DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1.1 Front Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2 UNPACKING AND INSPECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 3 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 4 POWER-UP/CHECK OUT PROCEDURE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 5 SPECIFICATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 6 OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 7 MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 8 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 9 CUSTOMER INFORMATION AND ASSISTANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 _________________________________________________________________________________________________________ INTRODUCTION This manual describes the OptEnet 1000 Mb/s Media Converter Module, and provides procedures for unpacking, installing, and operating this product. Revision History Content Page ISSUE DATE REASON FOR CHANGE 1 02/2004 Original Publication

ADCP-92-049 • Issue 1 • February 2004

Page 2 © 2004, ADC Telecommunications, Inc. List of Changes Trademark Information ADC is a registered trademark of ADC Telecommunications, Inc.; OptEnet is a trademark of ADC Telecommunications, Inc. Related Publications Listed below are related manuals and their publication numbers. Copies of these publications can be ordered by contacting the ADC Technical Assistance Center at 1-800-366-3891 (in U.S.A. or Canada) or 952-917-3000, extension 73475 (outside U.S.A. and Canada). OptEnet 4000 & 12000 Media Converter Chassis Installation Instructions 92-045 OptEnet 10/100 Mb/s Ethernet Media Converter Module User Manual 92-048 OptEnet SM-MM Media Converter Module User Manual 92-050 OptEnet Media Converter Communications User Manual 92-051 Admonishments Important safety admonishments are used throughout this manual to warn of possible hazards to persons or equipment. An admonishment identifies a possible hazard and then explains what may happen if the hazard is not avoided. The admonishments — in the form of Dangers, Warnings, and Cautions — must be followed at all times. These warnings are flagged by use of the triangular alert icon (seen below), and are listed in descending order of severity of injury or damage and likelihood of occurrence. PAGE IDENTIFIER DESCRIPTION OF CHANGE All New manual Title/Description ADCP Number Danger: Danger is used to indicate the presence of a hazard that will cause severe personal injury, death, or substantial property damage if the hazard is not avoided. Warning: Warning is used to indicate the presence of a hazard that can cause severe personal injury, death, or substantial property damage if the hazard is not avoided. Caution: Caution is used to indicate the presence of a hazard that will or can cause minor personal injury or property damage if the hazard is not avoided.

ADCP-92-049 • Issue 1 • February 2004

Page 3 © 2004, ADC Telecommunications, Inc. General Safety Precautions FCC Compliance Statement The OptEnet Media Converter modules and chassis have been certified to comply with the requirements for Class A computing devices per part 15 of the FCC regulations. UL/CSA Certification The OptEnet Media Converter modules and chassis have been tested and found to comply with the requirements of UL/CSA 60950. NEBS Certification The OptEnet Media Converter modules and chassis complies with the requirements of GR-63- CORE, Issue 1, October 1995 and GR-1089-CORE, Issue 2, December 1997 with Revision 1, February 1999 as specified in SR-3580, Issue 1, 1995. Danger: Infrared radiation is invisible and can seriously damage the retina of the eye. Do not look into the optical connector of an operational transmitter, or into the end of an active fiber. A clean, protective cap or hood MUST be immediately placed over any radiating connector or optical fiber to avoid exposure to potentially dangerous amounts of radiation. This practice also helps prevent contamination of connectors and adapters. Do not assume laser power is turned off or the fiber is disconnected at the other end. Danger: To avoid the possibility of severe and potentially fatal electric shock, never install electrical equipment in a wet location or during a lightning storm. Caution: Electronic modules can be damaged by electrostatic discharge (ESD). Before handling modules, wear an anti-static-discharge wrist strap to prevent damage to electronic components. Place modules in anti-static packing material when transporting or storing them. When working on modules, always place them on an approved, electrically grounded, anti-static mat. Warning: This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual, may cause interference to radio communications. It has been tested and found to comply with limits for a Class A digital device pursuant to Subpart B of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference to TV and radio reception in which case the user, at their own expense, will be required to take whatever measures may be required to correct the interference. This equipment does not exceed Class A limits for radio emission for digital apparatus, set out in the radio interference regulation of the authorization methods of Industry Canada. Operation in a residential area may cause unacceptable interference to TV and radio reception requiring the owner or operator to take whatever steps are necessary to correct the interference. This product conforms to all applicable standards of 21 CFR 1040.

ADCP-92-049 • Issue 1 • February 2004

Page 4 © 2004, ADC Telecommunications, Inc. 1 PRODUCT DESCRIPTION The OptEnet 1000 M/bs Media Converter module is one of a family of modules that can be plugged into an OptEnet Media Converter chassis. The module is designed to convert optical signals to electrical signals. The module also performs the reverse function, converting electrical signals to optical signals. A block diagram of the basic converter assembly is shown in Figure 1. Each module has three connections fiber input, fiber output, and RJ45 Ethernet. Figure 1. Basic 1000 Mb/s Media Converter Block Diagram OptEnet 1000 Mb/s Media Converter modules support 1000BaseT data rates with 1310nm singlemode, 850nm multimode fiber, or 1550nm singlemode fiber. Table 1 lists the supported protocols. 1.1 Front Panel The module has three LEDs. One module power LED and two Link LEDs. Under normal operation the module PWR LED is green. Front panel indicators and controls are defined in Table 2. A module front panel is shown in Figure 2. Table 1. Cable Specifications APPLICATION DATA RATE MEDIA DISTANCE INTERFACE 1000BaseT Gigabit UTP Cat 5e (4-pair) 328 feet (100 m) RJ45 1000BaseSX Gigabit 850 nm multimode fiber 850 nm multimode fiber 722 feet (220 m) 62.5/125µm 1804 feet (550 m) 50/125µm SC 1000BaseLX Gigabit 1300 nm singlemode fiber 1300 nm multimode fiber 6.2 miles (10 km) 9/125µm 1804 feet (550 m) 62.5/125µm or 50/125µm SC 1000BaseLH Gigabit 1550 nm singlemode fiber 43.5 miles (70 km) 9/125µm SC 18699-B OPTICAL TRANSCEIVER ETHERNET TRANSCEIVER LED OR LASER PIN RJ-45 UTP CABLE 1000Base-X MODULE FIBER CABLE

ADCP-92-049 • Issue 1 • February 2004

Page 5 © 2004, ADC Telecommunications, Inc. Figure 2. OptEnet 1000 Mb/s Converter Front View Table 2. Module LED Indicators SIGNAL COLOR STATUS TP Link GREEN Link status 1000 Mb/s is OK. OFF Link status failed or no Ethernet detected. FO Link GREEN Signal detect asserted, link status OK. OFF Signal detect de-asserted, link status FAIL or no Ethernet detected. PWR GREEN Module Power OK OFF Module Power OFF CONTROL DESCRIPTION Reset If module supply voltage drops below a predetermined value the module shuts down, pressing the reset button restarts the module. 18523-A

ADCP-92-049 • Issue 1 • February 2004

Page 6 © 2004, ADC Telecommunications, Inc. 2 UNPACKING AND INSPECTION Unpack and inspect the module as follows: 1. Inspect the exterior of the shipping container(s) for evidence of rough handling that may have damaged the components in the container. 2. Unpack module, carefully checking it for damage and verify with the packing slip. If any item is damaged, consult ADC for repair, replacement, and warranty information. Even though no damage is evident, save the shipping container for use if the equipment requires shipment at a future date. 3. File a claim with the commercial carrier and notify ADC Customer Service if damage is detected or if parts are missing. Save damaged cartons for inspection by the carrier. 4. Refer to Customer Information and Assistance if you need to contact ADC. 5. Save all shipping containers for use if the equipment requires shipment at a future date. 3 INSTALLATION Each module has a 2-position dip-switch for enabling or disabling the UTP (Unshielded Twisted Pair) Link upon detection of the fiber optic link. Position 1 enables or disables the UTP link independently of the fiber link. Position 2 reports the configuration to the CPU through the backplane interface. Position 1 and position 2 must be set to the same positions. If DIP switches are set to the ON position, then the UTP side follows the fiber side. For example, if the fiber side links then the UTP side links also. If fiber side is not linked or loses link, then UTP side is not allowed to link or will drop the link. If switch is configured to the OFF position, then UTP link does not follow the fiber link. The UTP side links regardless of the status of the fiber side. Table 3 shows the dip-switch positions. Caution: Electronic modules can be damaged by electrostatic discharge (ESD). To prevent this, take the following precautions: • Wear an anti-static-discharge wrist strap while handling modules. • Place modules in anti-static packing material when transporting or storing them. • Place modules on an approved, electrically grounded, anti-static mat when working on them. Table 3. Dip-Switch Positions DIP SWITCH DESCRIPTION 1 ON = UTP Link dependent of Fiber Link OFF = UTP Link independent of Fiber Link (Default position) 2 ON = Reports to CPU the UTP Link dependent of Fiber Link OFF = Reports to CPU the UTP Link independent of Fiber Link (Default position)

ADCP-92-049 • Issue 1 • February 2004

Page 7 © 2004, ADC Telecommunications, Inc. OptEnet Chassis should already be installed, power supplies installed, and power connections made before installing OptEnet 1000 Mb/s Media Converter Modules. Media converter modules can be safely removed and installed into a powered chassis. Module installation is shown in Figure 3. 1. Locate the designated slot in the chassis for the module. 2. Set the DIP switches to the desired settings. 3. Slide OptEnet 1000 Mb/s converter module into slot and plug it into connector on the backplane. Modules can be plugged into any empty slot in the chassis. All fiber connectors are mounted in straight retainers. Module is held in place with thumbscrew fasteners. Figure 3. Installing Media Converter Module 4. Secure the module in place by tightening the captive thumbscrews on each end. Be sure that they are properly threaded before tightening. 5. Verify that the POWER LED is lit. Danger: To avoid the possibility of severe and potentially fatal electric shock, never install electrical equipment in a wet location or during a lightning storm. Caution: Electronic modules can be damaged by electrostatic discharge (ESD). To prevent this, take the following precautions: • Wear an anti-static-discharge wrist strap while handling modules. • Place modules in anti-static packing material when transporting or storing them. • Place modules on an approved, electrically grounded, anti-static mat when working on them. Caution: Always allow sufficient fiber length to permit routing without severe bends. Fibers may be permanently damaged if bent/curved to a radius of less than 1.5 in. (3.81 cm). 18529-A MEDIA CONVERTER MODULE

ADCP-92-049 • Issue 1 • February 2004

Page 8 © 2004, ADC Telecommunications, Inc. 6. Remove the dust covers from the fiber cable ends and from the rear of the media converter. 7. Attach the fiber cable “TX” and “RX” connectors to the corresponding receptacles on the media converter. See Figure 4. 8. Each 1000 Mb/s media converter module has an RJ45 connector located on the front. Use this connector when making the copper Ethernet connection. If a RJ45 Patchcord is provided proceed to Step 9. The following steps describe how to make your own RJ45 Patchcord. Pinout information is shown in Table 4 and Figure 5. a. Use CAT 5E cable, strip back cable jacket to expose the four wire pairs, the metallic sheath, and drain wire (if present). b. Cut off metallic sheath and drain wire (if present) so that it is even with the outer jacket of the cables. c. The IEEE Specification for Ethernet 1000BaseT requires that four twisted pairs are used. One pair is connected to pins 1 and 2, pair two is connected to pins 3 and 6, pair three is connected to pins 4 and 5, and pair four is connected to pins 7 and 8. Figure 4. 1000 Mb/s OptEnet Media Converter Module Connections Danger: Infrared radiation is invisible and can seriously damage the retina of the eye. Do not look into the optical connector of an operational transmitter, or into the end of an active fiber. A clean, protective cap or hood MUST be immediately placed over any radiating connector or optical fiber to avoid exposure to potentially dangerous amounts of radiation. This practice also helps prevent contamination of connectors and adapters. Do not assume laser power is turned off or the fiber is disconnected at the other end. 18522-A RJ45 CONNECTOR OPTICAL TRANSMIT OPTICAL RECEIVE

ADCP-92-049 • Issue 1 • February 2004

Page 9 © 2004, ADC Telecommunications, Inc. Figure 5. RJ45 Connector Wiring 9. Connect Ethernet RJ45 patchcord to RJ45 receptacle on the converter module. 10. Verify that the front panel LEDs are active. Link LEDs are not lighted if there is no Ethernet or optical signal present. 4 POWER-UP/CHECK OUT PROCEDURE Media Converter Modules are powered up as soon as power is applied to the chassis. The POWER indicator (GREEN LED) on the converter module should light to indicate that VDC power is applied to the media converter. If the POWER indicator does not come on, verify that the power connections between the Media Converter Module and the power supply are secure. Verify that there is power present at the source. If this procedure does not resolve the problem, replace the cable or power supply. OptEnet 1000 Mb/s Media Converter modules support Medium Dependent Interface Crossover (MDI-X). OptEnet Media Converter Module Ethernet ports allow connections to other hubs or switches without a null-modem or crossover cable. If a null-modem or crossover cable has been used the OptEnet 1000 Mb/s Media Converter module automatically detects this and switches the contacts to match the other end. Set data rate speed to 1000 Mb/s and enable half/full duplex auto-negotiate on any equipment connected to the OptEnet 1000 Mb/s Media Converter module. If the Network Interface Card (NIC) or port in the PC workstation has been set to 1000 Mb/s for speed and half/full duplex auto-negotiate, the link LED will be OFF when power is applied. Once valid optical and electrical links have been established, link LEDs turn GREEN. Table 4. 1000BaseT Ethernet RJ45 Connector PIN # SIGNAL NAME FUNCTION PIN # SIGNAL NAME FUNCTION 1 BD1+ Bidirectional 2 BD1– Bidirectional 3 BD2+ Bidirectional 4 BD3+ Bidirectional 5 BD3– Bidirectional 6 BD2– Bidirectional 7 BD4+ Bidirectional 8 BD4– Bidirectional RJ-JACK PIN 1 PIN 8 11899-A

ADCP-92-049 • Issue 1 • February 2004

Page 10 © 2004, ADC Telecommunications, Inc. 5 SPECIFICATIONS Table 5, Table 6, and Table 7 lists the specifications for the module. Table 5. Module Environmental Specifications PARAMETER SPECIFICATION REMARKS Operating Conditions 41°F to +104°F (5°C to +40°C) Per Telcordia GR-63 Short Term Conditions +23°F to +122°F (−5°C to +50°C) Per Telcordia GR-63 Storage Conditions −40°F to +160°F (−40°C to +70°C) at 5% to 95% RH Non-condensing Table 6. Electrical and Mechanical Specifications PARAMETER SPECIFICATION REMARKS Electrical Operating Voltage +5 VDC Backplane connector Input power 2.2 W max. Normal operation Mechanical Dimensions (H×W×D) 1.14 in.× 8.07 in.× 7.4 in. (2.89 cm × 20.5 cm × 18.8 cm) Chassis Compatibility OptEnet Media Converter All modular systems Module Retention Captive thumbscrews Weight 0.27 lb. (122 g.) Electrical Signal Interface RJ45 Four twisted pair 1000 Mb/s Optical Signal Interface SC Duplex Singlemode (9/125µm) 1310 nm SC Duplex Multimode (62.5/125µm or 50/125µm) 850 nm/1300 nm

ADCP-92-049 • Issue 1 • February 2004

Page 11 © 2004, ADC Telecommunications, Inc. 6 OPERATION The Module may be controlled through a Command Line Interface. Refer to the OptEnet Media Converter Communications User Manual listed in Related Publications, for SNMP procedures that pertain to the CPU module. 7 MAINTENANCE Follow standard cleaning practices for maintenance of fiber adapters and connectors. Table 7. Optical Specifications NETWORK SPECIFICATION REMARKS SingleMode (9/125µm) 1270 nm min./1355 nm max. Wavelength (1310 nm typical) 1480 nm min./1580 nm max. Wavelength (1550 nm typical) Output Optical Power 1000Base-LX –11 dBm min. to –3 dBm max. 1000Base-LH –3 dBm min. to 2 dBm max. Input Optical Power 1000Base-LX –20 dBm min. to –3 dBm max. 1000Base-LH –23 dBm min. to –3 dBm max. MultiMode (50/125µm or 62.5/125µm) 820 nm min./860 nm max. Wavelength (850 nm typical) 1270 nm min./1360 nm max. Wavelength (1300 nm typical) Output Optical Power 1000Base-SX –9.5 dBm min. to –4 dBm max. 850 nm VCSEL Input Optical Power 1000Base-SX –17 dBm min. to –3 dBm max. 850 nm

ADCP-92-049 • Issue 1 • February 2004

Page 12 © 2004, ADC Telecommunications, Inc. 8 TROUBLESHOOTING This section provides a troubleshooting flowchart, and corrective actions for the Module. Does the PWR LED on Media Converter Module light? NO YES NO 1. 2. If either Link LED is off, link status failed or no Ethernet is detected. Check optical or copper path for signal. Repair as necessary following local practices. YES Power-up the Media Converter Module by plugging it into the Chassis. 18693-A Do both Media Converter Module Link LEDs light green? Press the reset button, if the PWR LED does not turn green the module may be defective. Replace the Media Converter Module with a known good module. Does the PWR LED on Media Converter Module light? NO Pull out and insert the Media Converter Module into the slot so the backplane connector seats properly. Module is operating properly, signal detect is asserted and link status is OK.

ADCP-92-049 • Issue 1 • February 2004

Page 13 9 CUSTOMER INFORMATION AND ASSISTANCE © 2004, ADC Telecommunications, Inc. All Rights Reserved Printed in U.S.A. 13944-K WRITE: ADC TELECOMMUNICATIONS, INC PO BOX 1101, MINNEAPOLIS, MN 55440-1101, USA ADC TELECOMMUNICATIONS (S'PORE) PTE. LTD. 100 BEACH ROAD, #18-01, SHAW TOWERS. SINGAPORE 189702. ADC EUROPEAN CUSTOMER SERVICE, INC BELGICASTRAAT 2, 1930 ZAVENTEM, BELGIUM PHONE: EUROPE Sales Administration: +32-2-712-65 00 Technical Assistance: +32-2-712-65 42 EUROPEAN TOLL FREE NUMBERS UK: 0800 960236 Spain: 900 983291 France: 0800 914032 Germany: 0180 2232923 U.S.A. OR CANADA Sales: 1-800-366-3891 Extension 73000 Technical Assistance: 1-800-366-3891 Extension 73475 ASIA/PACIFIC Sales Administration: +65-6294-9948 Technical Assistance: +65-6393-0739 ELSEWHERE Sales Administration: +1-952-938-8080 Technical Assistance: +1-952-917-3475 Italy: 0800 782374 PRODUCT INFORMATION AND TECHNICAL ASSISTANCE: Contents herein are current as of the date of publication. ADC reserves the right to change the contents without prior notice. In no event shall ADC be liable for any damages resulting from loss of data, loss of use, or loss of profits and ADC further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages. This disclaimer of liability applies to all products, publications and services during and after the warranty period. This publication may be verified at any time by contacting ADC's Technical Assistance Center. [email protected] [email protected] [email protected]