Radio Systems CT-2002 Manual 

Specifications

Brand: Radio Systems
Category: Timer
Model: CT-2002 (Manual )
File Type: PDF
File Size: —
Pages: 25

Read Online

Read the Radio Systems CT-2002 Manual  online using the built-in PDF viewer.

Text of the manual

Radio Systems, Inc.

CT-2002 Clock/Timer Manual For Models: CT-2002 Desktop CT-2002 Thin CT-2002 Large 2” CT-2002 Large 4” CT-2002 Console CT-2002 Desktop GPS CT-2002 2” GPS CT-SYNC Clock to PC Synchronization Kit GPS-SYNC GPS to PC Synchronization Kit *Updated SEPTEMBER 2008 Applies to units with software versions CT-2007 Includes Remote Control Enhancements & New Daylight Savings Time Schedule

Radio Systems, Inc.

CT-2002Manual TOC Contents General Description Models......................................................................................................4 Options.....................................................................................................4 General Operating Instructions Clock/Timer (Mode) Select........................................................................5 To Set the Clock........................................................................................5 To Use the Up Timer.................................................................................5 To Utilize as Slave Clock Display.............................................................6 To Utilize as Slave Timer Display.............................................................7 Time-of-Day Offset....................................................................................8 Infrared Remote Control Up Timing.................................................................................................9 Down Timing............................................................................................9 Storing Down Times..................................................................................9 Recalling Stored Down Times.................................................................10 On Power Up..........................................................................................10 Time-of-Day Set......................................................................................10 Setting to Slave Display...........................................................................10 Setup Functions.......................................................................................11 Infrared Remote Control Diagram...........................................................13 GPS Driver Additional Operating Instructions............................................................14 Setup Programming.................................................................................14 Top-of-Hour Closure...............................................................................14. Connections and Installation...................................................................14 Operation................................................................................................15 GPS Error Codes......................................................................................15

Radio Systems, Inc.

CT-2002 Manual TOC Synchronization and GPS Extender Kits PC Synchronization.................................................................................16 GPS Antenna Cable Extenders ................................................................17 Wiring and Programming Diagrams Remote Connections to the CT-2002 Clock/Timer..................................18 Serial Time-of-Day Connections from CT-2002 GPS or Master Models...19 Serial Clock Timer Connections between CT-2002 Stand Alone Models 20. Using RJ-45 Patch Cords Serial Clock Timer Connections between CT-2002 Stand Alone Models 21. Using Twisted Pair Wiring GPS Antenna Wiring Diagrams...............................................................22 CT-2002 GPS Dip Switch Settings Diagram............................................23 Policies Warranty.................................................................................................24 Repair Policy...........................................................................................24 Return Instructions..................................................................................24 Note: Master Desktop and Master 2” models are no longer manufactured. Analog clocks are no longer manufactured. For operating and connection information for these products consult www.radiosystems.com/technotes.html

Radio Systems, Inc.

CT-2002 Manual Page  General Description The CT-2002 series of digital clock/timers is a family of timing displays, a master driver and a GPS driver. Models All Display Models: Will accept serial Time-of-Day and timer data in Radio Systems format, or Time-of-Day (only) data in SMPTE format. Provides up-timing as standard and down-timing with the optional IR remote control. Each display model (with V2005 or higher software) will output serial data for Time-of-Day in Radio Systems format. CT-2002 Desktop 4” deep x 3” high Desktop clock/up-down timer with 3/4” LED displays which functions as a stand alone or slave time of day display with wired remote control. CT-2002 Thin 1” deep x 3” high “stick-on” clock/timer with 3/4” LED displays featuring the same functions as the desktop unit, but in a smaller profile cabinet. CT-2002 2” 2” deep x 5” high clock/timer display with 2” high LED display and the same features set as the . “desktop” and “thin” units. CT-2002 4” 2” deep x 5” high clock/timer display with 4” high LED display and the same features set as the . “desktop” and “thin” units. Master & GPS Models: Provide up-timing and output serial Time-of-Day data in Radio Systems format. Options Infra-Red Remote Control Required for down timing and internal setup func- tions. Also provides clock operation, Time-of-Day Set and up-timer functions (for display units only.) Included with Desktop & Large Display. RS-485 Converter Installs in-line between the GPS satellite antenna and clock/receiver. Required for cable runs in excess of 150’.

Radio Systems, Inc.

CT-2002 Manual Page 5 General Operating Instructions For all non GPS or master units (applies to units utilized in stand-alone and slave display capacities.) Time-of-Day Set Up and Up-Timer functions can be controlled by the front panel buttons or the wired remote control. However, the IR Remote Control must be used for entering down times and internal setup functions. Front Panel or Wired Remote Operation Clock/Timer (Mode) Select All CT-2002 units operate as both clocks and timers. Switch between modes by pressing the MODE button on the front of the unit. The front panel LED’s will light to indicate the mode selected. Note that on the CT-2002 large wall display models, the mode switch is available on the remote control only. The fourth front panel switch is used to put the clock into the set mode. To Set the Clock: Note: If Serial Time of Day is supplied to the CT-2002 (slave mode), it will not be possible to enter the Time-of-Day set mode. Setting the time-of-day can either be done at the master unit or the displayed hours can be offset via the IR Remote Control. 1. Press the mode button to select the Time-of-Day display. The Clock LED will illuminate. 2. (Desktop and Thin models) - press and hold the STOP and START buttons. The Set LED will illuminate.. (Large models) - press the SET button. The Set LED will illuminate. 3. Display resets to 12:00:00 4. Press the STOP button to advance the hours. Press the RESET button to advance the minutes (note - seconds are not setable and remain at :00). 5. Start the clock at the top of the minute by pressing the START button. . The Set LED will extinguish. To Use the Up Timer: (To utilize as a Down-TImer consult IR Remote Control Instructions page 8) 1. Press the Mode Button to select the timer display. The Timer LED will . illuminate. 2. Press the START button to start timing. 3. Press the STOP button to stop timing. 4. Press the RESET button to return the display to 00:00.

Radio Systems, Inc.

CT-2002 Manual Page 6 Slaved Displays To Utilize as a Slaved Clock Display (CT-2002 Display units only): 1. Consult page 10 for setup functions to select either RS or SMPTE sync format. 2. Provide serial data to the unit. Choices of serial data are SMPTE time code and Radio Systems Time-of-Day data from CT-2002 GPS or CT-2002 Master units. In addition a CT-2002 display unit can be used to provide Time-of-Day and Timer data in the Radio Systems format. To connect to slave Time-of- Day displays only, wire only the serial data input terminals in parallel (use either the terminal strip or RJ-45 connectors—see the connections diagram on page 22). 3. The “SYNC” front panel LED will light and the time-of-day will immediately synchronize to the master unit readout. 4. Time-of-Day setting is now no longer available on this slave display. Time-of- Day setting must be made to the unit providing the serial Time-of-Day data. 5. If the data link is lost, the clock will revert to stand-alone local operation and the sync LED will extinguish. 6. Local timer functions continue to be available as described on the preceding page. 7. The minutes and seconds may be offset from the top of hour input closure. See manual section “Time-of-Day Offset on page 8 and “IR Remote control” section. 8. The hour, minutes and seconds may be offset from the upstream time-of-day serial data via the infra-red remote control. See manual section “Time-of-Day Offset on page 8 and “IR Remote control” section. Note: software/hardware kit is available (Radio Systems part # CT-SYNC) to update Windows PC clocks from your CT-2002 serial data stream

Radio Systems, Inc.

CT2002 Manual Page  To Utilize as a Slaved Timer Display as well as a slaved clock dis- play. (CT-2002 Display units only): 1. Consult page 11 for Setup function programming, and choose selection . 3 option “RS2” for slave timer operation. 2. Provide serial data from any CT-2002 display unit whose timer display you want to slave. Connect the serial data output terminals of the up-stream . CT-2002 display to the serial data input terminals of the slave display. Use either terminal strip or RJ-45 connectivity (consult wiring diagram on page 20 & 21.) 3. Place the slave display in the clock mode and confirm that the “SYNC” front panel LED on the slave display is lit and that the slave displays shows the Time-of-Day from the up-stream unit. 4. In the “Clock” mode, the time-of-day on the slave display will now synchro- nize to the up-stream stand alone display (regardless of what mode is being . displayed on the stand-alone upstream display.) 5. Place the slave display in the timer mode and press the “MEM 6” button on the IR remote control. Confirm that the SYNC LED on the slave lights and that the slave display shows the timer data from the up-stream display unit. 6. To return the slave display to none-slaving timer (stand-alone) functionality, press the “RESET” button on the IR remote control with the slave display in the timer mode. The “SYNC” LED will extinguish and the timer display will reset to 00:00, allowing local (IR and parallel) timer control. 7. To return to slave timer operation, push the “MEM 6” button on the IR remote control with the slave display in the timer mode. The “SYNC” LED will (re)illuminate and the display will synchronize to the up-stream stand- alone timer display. 8. Additional timers “downstream” from this slave timer may be wired to slave to this timers display, or function as Time-of-Day displays and independent stand-alone timer displays. Consult the wiring diagram on page 20 (RJ-45 patch cord wiring) or 21 (twisted pair wiring) for specific wiring configura- tions. Wired Remote Control All front panel controls are available on the rear barrier strip connector. Contacts are momentary / pull-to-ground. See attached wiring diagram for connections - page 18.

Radio Systems, Inc.

CT2002 Manual Page  Time of Day Display Offset The time of day displayed on CT2002 displays slaved from upstream GPS or Master clocks or triggered by top-of-hour input closures can be offset by any amount of seconds, minutes, or hours. Typical applications ofr such an offset: •Network Top-of-hour pulses sent early (seconds before the . actual top-of-hour) . • Stations running in full obsentity delay. • HD station transmission delay. • Time zone multi clock displays To offset closure reset: Use the infrared remote control option 10 position to enter the minutes and or seconds desired to be displayed when the top of hour closure is received.. • Note that hours displayed will not be affected. . • Note that top-of-hour is only active prior to and after the hour (to avoid false triggers at other times).. • See manual page 12 for programming instructions. To offset serial time input from and upstream GPS or Master clock in the serial chain (RS serial time code or SMTPE time code allowed): Use the infra red remote control to input hours to be added to time of day serial data (option 4), or minutes and or seconds to be added to the time of day serial data (option 11).. • Note that offsets are always added to the stream. For example:. To offset plus 1 hour, 10 seconds - set option 4 for 01 and . option 11 for 00:10. To offset minus 8 seconds - set option 4 for 23 and . option 11 for 00:52

Radio Systems, Inc.

CT-2002 Manual Page 9 Infra Red Remote Control (CT-2002 Display units only) Up Timing 1 Press the Timer Button to place the CT-2002 into the Timer Mode. The Timer LED will illuminate. (If the “Down” LED is illuminated, press the Reset Button. It may require two presses.) 2. Press the Start Button to start up timing. 3. Press the Stop Button to stop up timing. 4. Press the Start Button to resume up timing. 5. Press the Reset Button to clear the display. Down Timing 1. Press the Timer Button. The Timer LED will illuminate. 2. Using the numeric keypad, enter a down time. The Set LED and Down LED will illuminate. Hours can be from 00 to 99, minutes from 00 to 59 and sec- onds from 00 to 59. Erroneous entries can be overwritten or the Reset Button can be used to zero the display. An invalid time such as 12:60:00 will be cleared when the Start Button is pressed. 3. Press the Start Button to begin down timing. (The down timer can be set to either stop at zero or continue to count negative. See IR Remote Setup Functions - see page 10.) 4. Press the Stop Button to stop down timing. 5. Press the Start Button to resume down timing. 6. Press the Reset Button once to recall the entered down time. Repeat steps 3 through 6 as desired. 7. Press the Reset Button two times to exit the down mode (and to clear the . display and return to up timing mode). Storing Down Times The IR Remote Control can be used to store up to six down times. These times are saved when power is removed from the CT-2002. 1. Press the Timer Button. The Timer LED will illuminate. 2. Using the numeric keypad, enter a down time. The Set LED and Down LED will illuminate. Hours may be from 00 to 99, minutes from 00 to 59, and sec- onds from 00 to 59. Erroneous entries can be overwritten or the Reset button can be used to zero the display. 3. Press one of the Store Buttons. If the time entered was valid, the display will momentarily flash, the Set LED will extinguish and the down time will be stored. In addition, the entered down time will remain on the display and the Down LED will remain illuminated. However, an invalid time (such as 12:60:00) will be cleared when a Store Button is pressed. In addition, the . CT-2002 will return to the Up Timer Mode. 4. Repeat steps 2 and 3 as desired.

Radio Systems, Inc.

CT-2002 Manual Page 10 Recalling Stored Down Times Previously stored down times in locations MEM1 thru MEM6 may be recalled either with the IR remote control or via the wired remote control. See connection diagram page 18. 1. Press the Timer Button. The Timer LED will illuminate. 2. Press one of the Store Buttons. 3. The stored down time will appear on the display. The Down LED will illumi- nate. 4. Press the Start Button to begin down timing. 5. Press the Stop Button to stop down timing. 6. Press the Start Button to resume down timing. 7. Press the Reset Button once to recall the selected down time. Repeat steps 3 through 6 as desired. 8. Press the Reset Button two times to exit the down mode (return to up timing mode) and clear the display. On Power up 1. Units always power up into the time-of-day mode. 2. If serial data (RS or SMPTE) is supplied (and the correct mode was pre-select- ed with the IR Remote Control), then the serially supplied time will display. 3. The clock must be set when using the internal clock base. Time-of-Day set The CT-2002 will not enter the Time-of-Day set mode if serial time of day is being supplied by a master clock or GPS system. However, the displayed time may be offset up to 23 hours, (see IR Remote Setup Functions - page 13). 1. Press the Clock Mode Button to put the CT-2002 into the Clock Mode. . The Clock LED will illuminate. 2. Press the Time-of-Day set button. The Set LED will illuminate. 3. Using the numeric keypad on the IR Remote Control enter the correct time. The display will advance to the next digit only if a valid time has been entered. In the event of an erroneous entry, press the Time-of-Day set button to start over. 4. Press start at the correct moment. Setting the Timer to Act as a Slave Display Timers can be wired to slave the display of an upstream timer. Consult wiring dia- gram on pages 20 & 21for details. 1. When in timer mode, press the MEM 6 button on the IR remote control. The “SYNC” LED will illuminate and the timer will display the upstream time . (the slave display must be receiving timer data from and up-stream timer, and RS2 must be selected in IR setup option three.) 2. Press the Reset Button “when in timer mode” to force the timer to operate as a local up/down timer. The “SYNC” LED will extinguish and the timer dis- play will reset to 00:00. Operate the timer as usual. 3. Press the “MEM 6” button on the IR Remote Control to revert to slave timer readout.

Radio Systems, Inc.

CT-2002 Manual Page 11 Setup Functions The IR Remote Control is used to set various functions of the CT-2002. With the exception of “IR Remote Disable” these selections are stored if power is lost. 1. Press the Program Button. The “PGM” LED will illuminate. Repeatedly press- ing the Setup Button will step the CT-2002 through the 10 menu choices. 2. The selections are changed either by pressing the “Clock” set button or using the numeric keypad. 3. The Setup Mode is exited (and the selections are stored) by pressing either the Clock Button or the Timer Button. 4. For a confidence check that your programming changes have been made and stored, cycle thru the setup functions without making any more changes to check that your entries are saved. Then press clock or timer to exist. Option 1: 12/24 hour clock operation. Press the “Clock” set . button to toggle between 12 and 24 hour operation. Option 2: Down timer stop at zero or count negative. Press the . Time-of-Day set button to toggle between hold at 0 or go negative. Option 3: Serial time of day format. Press the “Clock” set button to toggle between Radio Systems-1 (rS1) format, Radio Systems-2 (rS2) format and SMPTE (SP) format . “SMPTE” enable the serial input to read standard SMPTE . format (no drop frame ). “rS1” enables the serial inputs to read Radio Systems serial time of day format as generated by Radio Systems’ GPS, Master, and stand-alone clocks. “rS2” enables the serial inputs to read Radio Systems serial time of day format as well as upstream timer displays. Note that in this mode, the “Mem 6” and RESET keys on the IR Remote control is retasked to allow switching between slave and local timer functions. Option 4: Serial time of day hour offset. Press the “Clock” set button to select from 00 to 23 hour added to the serial time of day data. Use option 11 to input minutes and seconds added. Option 5: IR Remote Functionality. Press the “Clock” set button to toggle between full functionality (iron), program defeat (irPr), and no remote (irno). In program defeat (irPr) the setup functions are locked out. When AC power is toggled off and on, the remote returns to full functionality. In no remote (irno) all remote functions are ignored. When AC power is toggled off and on, the remote returns to full functionality. Use this function if there is more than one clock in use in the same room.

Radio Systems, Inc.

CT2002 Manual Page 12 Option 6: Time compare 1. Use the numeric keypad to enter the minutes and seconds of the time compare. Time between 00:00 and 59:59 must be entered. Note that all four dig- its (including leading zeros) must be entered. When the minutes and seconds of the time of day are equal to the time compare stored, the matching open collector wired remote will activate. Option 7: Time compare 2. See “option 6” above. Option 8: Time compare 3. See “option 6” above. Option 9: Time compare 4. See “option 6” above. Option 10: Top of Hour Reset Offset. A wired remote input is . available for top of hour reset. The default operation . is to reset the time-of-day to 00 min’s. & 00 sec’s. . Use the numeric keypad to reset to a different time, . (minutes and seconds). When the displayed time of day is within a +- 5 minute window of the stored top of hour time and the wired remote input is activated, the displayed time will be replaced by the stored top of hour time. (This function active for stand-alone time-of-day operation only.) Option 11: Serial time of day minutes and seconds offset. Use the numeric keypad to enter the minutes and seconds desired to be added to the serial time of day data. Use option 4 to input hours to be added.

Radio Systems, Inc.

CT-2002 Manual Page 13 RESET STOP START CLOCK TIMER CLOCK SET PROGRAM 1 2 3 4 5 6 7 8 9 0 MEM 1 MEM 2 MEM 3 MEM 4 MEM 5 MEM 6 Storing Down Times 1. Press the Timer Button. The Timer LED will illuminate. 2. Using the numeric keypad, enter a down time. The Set LED and Down LED will illumi- nate. Hours may be from 00 to 99, minutes from 00 to 59, and seconds from 00 to 59. Erroneous entries can be overwritten or the Reset button can be used to zero the display. 3. Press one of the Store Buttons. If the time entered was valid, the display will momen- tarily flash, the Set LED will extinguish and the down time will be stored. In addition, the entered down time will remain on the display and the Down LED will remain illuminated. However, an invalid time (such as 12:60:00) will be cleared when a Store Button is pressed. In addition, the CT-2002 will return to the Up Timer Mode. 4. Repeat steps 2 and 3 as desired. Recalling Stored Down Times 1. Press the Timer Button. The Timer LED will illuminate. 2. Press one of the Store Buttons. 3. The stored down time will appear on the display. The Down LED will illuminate. 4. Press the Start Button to begin down timing. 5. Press the Stop Button to stop down timing. 6. Press the Start Button to resume down timing. 7. Press the Reset Button once to recall the selected down time. Repeat steps 3 through 6 as desired. 8. Press the Reset Button two times to exit the down mode (return to up timing mode) and clear the display Note: Stored Down-Time 1 can be recalled remotely via parallel remote control wiring. See illustration page 18. Push to display Time-of-Day Push to freeze Timer Display When Up-Timing: Push once to reset timing to 00:00 . (Continues to run if reset from Stop) . (Holds if reset from Stop) When Down-Timing: Push once to redisplay down time.. Push again to return display to 00:00 . and Up-Time mode. In Clock Mode: Starts display running from . Time-of-Day set mode In Timer Mode: Starts display running from . Up or Down Timer display Push for Timer Mode Push to set Time-of-Day Enter via numeric keypad. Push start. Push to set Internal Programming fea- tures (see setup functions on page 10). Program functions via . numeric keypad. Push Timer or Clock to exit . in that mode To set down time Enter time via numeric keypad. Push start to begin. Push reset to recall downtime. Push reset 2x to exit. CT-2002 InfraRed Remote Control MEM 6 is retasked to switch the timer between slave and local modes when using associated dis- play as a remote timer. See page 7.

Radio Systems, Inc.

CT-2002 Manual Page 14 GPS Driver Additional Operating Instructions Setup Programming Refer to the dip-switch setting diagram on page 23 to program the hour offset from GMT for your time zone, to enable the automatic daylight savings time setting, and to enable 12 or 24 hour operation. Note that the unit is shipped with the factory default setting of Eastern Time Zone (5 hours behind GMT), auto daylight savings time switch-over and 12-hour operation. The analog clock dip-switch (switch #1) causes the display to flash after recovery from a satellite signal loss as an operator indication that your analog clocks have lost time and must be reset. (Digital clocks connected to the GPS Master driver will automatically update.) After adjusting the time on the analog clock (see ana- log clock operation), push the start button to cease flashing and resume normal display. Factory default for this feature is “off”. Top-of-Hour Closure GPS Master driver units (on 2”, 4” and desktop) provide a top-of-hour closure available as a C-form relay closure for 250 ms, occurring at the top of each hour. The C-form contacts are available on the rear remote control barrier strip . connector on pins 15 and 16 (last two terminals on the strip). See Remote Connection diagram p19 of this manual for connections. Connections and Installation 1. Mount the antenna on a roof or window ledge with a clear view of the sky. Avoid areas directly under microwave antenna paths, or near dense foliage. 2. The antenna plugs into the clock/receiver via a pre-installed RJ-45 Ethernet style connector. Up to 150’ of four conductor shielded cable may installed between the antenna and the receiver. This cable may be user provided, or a pre-assembled 150’ or 250’ extension cable is available from Radio Systems. Please note that for any cable run in excess of 150’, in-line balancing RS-485 convertor amplifiers, available from Radio Systems, must be installed. For wiring specifications, see the attached antenna wiring detail on page 23.

Radio Systems, Inc.

CT-2002 Manual Page 15 Operation 1. After all connections are made, apply power. The unit will take from 1 to 15 minutes to acquire the satellite data. During this initial acquisition period, and during any subsequent periods of satellite data loss, the GPS Master unit will display one of 5 error codes. These codes and their meanings are listed below. 2. After acquisition, the true time will display and will be serially relayed to any digital display units “downstream”. If data is lost at any time in the future, downstream display “data” lamps will extinguish, but these clocks will con- tinue to run on their internal time base. On satellite reacquisition, the time will be updated, and the “data” lamps re-illuminated. 3. Front panel master GPS controls cannot be used to set or change the digitally displayed time-of-day, but the time mode may be used to adjust the time on any analog clocks connected, and the START, STOP and RESET switches may be used in the timer mode. See the “Analog Clock Connection and Use” sec- tion for operating details. GPS Error Codes These two digit error codes will display in the GPS Master readout in the center two digits on unit turn-on (pre-satellite acquisition) and during any data outage. Error Code 1-Pulse Per Second Serial Data Data 01 (1 PPS line broken) not present present okay 02 (satellite acquisition lost) present present bad 03 (fire-up status - first 1 to 15 minutes) not present present bad 04 (corrupted serial data output) present not present bad 05 (no antenna connection) not present not present bad

GPS-SYNC Synchronization Kit

This hardware and software kit allows time code received directly from GPS antenna to be read into a PC COMM (RS232 serial) port.. The kit includes an antenna, antenna outdoor mount, 12ft. connectorized serial cable, power supply and interface box, and software. A 150ft. extension cable is available as well as RS-485 for extended cable runs up to 500ft. Included software installs in any Windows 2000 or higher OS and automatically updates the Windows time base with GPS accurate time. Hours, minutes and sec- onds offset can be set manually by software configuration screens. PC-SYNC Synchronization Kit This hardware and software kit allows a PC’s time base to be updated via RS serial time code, OR allows a PC’s time base to output RS serial time code. Connection to the PC is via USB and connection to CT-2002 is via two wire twisted pair serial cable.. The kit includes a USB to RS422 converter and software. One included software program installs in any Windows 2000 or higher OS and automatically updates the Windows time base with CT-2002 serial time. A second software program included installs in any Windows 2000 or higher OS and auto- matically updates the CT-2002 clock system from the PC time base. Hours, minutes and seconds offset can be set manually via the software . configuration screens or in the CT-2002 software. Radio Systems, Inc. CT-2002 Manual Page 16 To/from RS serial . clock time code . via two wire . RS222 connection

Radio Systems, Inc.

CT-2002 Manual Page 17 GPS Antenna Cable Extension CT-150 GPS - 150ft. Extension Cable 150ft. of shielded CAT-5 cable with “biscuit” style RJ-45 termination boxes at each end. GPS antenna plugs into far side and near is connected to GPS clock via an RJ-45 patch cable (provided.) Note: This cable may be shortened by the customer, but 150ft. is the maximum distance that the antenna cable may be extended without the use of the active RS- 485 converter boxes (below.) CT-250 GPS - 250ft. Active Extension Kit 250ft. of shielded CAT-5 cable with active RS-232 to RS-485 extender ‘biscuits”. GPS antenna plugs into far side and near is connected to GPS clock via an RJ-45 patch cable (provided.) Converter biscuits are active and powered via the GPS clock power supply. Note: The antenna side RS-232 converter is not in a water-proof box and must be housed indoors or in a protective closure.

Radio Systems, Inc.

CT2002 Manual Page 18 Remote Control Connections to CT-2002 Clock/Timer Models GND SERIAL OUT - SERIAL OUT + GND START SWITCH STOP SWITCH RESET SWITCH MODE SWITCH GND TIME CLOSURE 1 TIME CLOSURE 2 TIME CLOSURE 3 TIME CLOSURE 4 GND DOWN TIME CLOSURE AT “0” TOH RESET INPUT RJ-45 OUT RJ-45 IN 9V DC IN MODEL CT-2002 DESKTOP Part No. 14409 SERIAL IN + SERIAL IN - RJ-45 SHIELD TO GND Logan Township, New Jersey USA 1-856-467-8000 • www.radiosystems.com CT-2002 Desktop START TOH RESET STOP RESET MODE Time Closures Pull to Ground Ground on Timer Remote rrier Stri GROD se  or oter ener l urose sinl diodes se n enerl urose SPST momentrt us utton or to StudioHu T nels Position  in timer mode MEM 1 MEM 2 MEM 3 MEM 4 MEM 5 MEM 6 Position  in timer mode Position  in timer mode Position  in timer mode Position  in timer mode Position  in timer mode CT-20022 Connetions to Timer Remote rrier Stri STOP RESET MODE START START START STOP STOP START RESET MODE MODE MODE MODE o ee stoe eo postos  t   e eote e to eote tes so o Desktop   oes ote tt stee oes ot sppe st e ste GND +15V DC IN 1 2 3 4 5 6 7 8 9 10 1112131415 1617181920 Anciary 16- Ground 17- Down Time Closure at “0” 18- Top-of-Hour Input 19- Ground 20- +15V DC emote ont ro 6- Ground 7- Start 8- Stop 9- Reset 10- Mode oc Triggers 11- Ground 12- Time Closure #1 13- Time Closure #2 14- Time Closure #3 15- Time Closure #4 Seria Synchroniing ata 1- Serial In + 2- Serial In - 3- Ground 4- Serial Out - 5- Serial Out + T NTL A ST N-UTS TOH RESET STOP RESET MODE Time Closures ull to round START GRO D 1 2 3 4 5 6 7 8 A CK DIP SWITCHES UP IS ON SERIAL DATA OUT + SERIAL DATA OUT - GROUND START SWITCH STOP SWITCH RESET SWITCH MODE SWITCH GROUND AHEAD DC TO CLOCKS 10 H TO CLOCKS GROUND COMMON N. O. CONTACT ANTENNA 15V DC IN 1 H OUT TO IMPULSE DRIVER TO ANALOG CLOCKS TOP O HOUR CLOSURE MODEL CT-2002 GPS Part No. 14411 CT-2002 START TOP O HO R REA COSRE STOP RESET MODE Logan Township, New Jersey USA 1-856-467-8000 • www.radiosystems.com CT-2002 START TOH RESET STOP RESET MODE Time Closures ull to round DOWN TIME CLOSURE AT “0” GND TOP O HOUR RESET INPU T TIME CLOSURE 4 TIME CLOSURE 3 TIME CLOSURE 2 TIME CLOSURE 1 GND SERIAL OUT - SERIAL OUT + +9V DC IN GND GND START SW STOP SW RESET SW MODE SW GND SERIAL IN - SERIAL IN + 4 6

Radio Systems, Inc.

CT2002 Manual Page 19 Serial Time of Day Connections from CT2002 and GPS Models Note: software/hardware kit is available (Radio Systems part # CT-SYNC) to update Windows PC clocks from your CT-2002 serial data stream GND SERIAL OUT - SERIAL OUT + GND START SWITCH STOP SWITCH RESET SWITCH MODE SWITCH GND TIME CLOSURE 1 TIME CLOSURE 2 TIME CLOSURE 3 TIME CLOSURE 4 GND DOWN TIME CLOSURE AT “0” TOH RESET INPUT RJ-45 OUT RJ-45 IN 9V DC IN MODEL CT-2002 DESKTOP P art No. 14409 SERIAL IN + SERIAL IN - RJ-45 SHIELD TO GND Logan Township, New Jersey USA 1-856-467-8000 • www .radiosystems.com 1 2 3 4 5 6 7 8 BACK DIP SWITCHES (UP IS ON) SERIAL DA TA OUT + SERIAL DA TA OUT - GROUND START SWITCH STOP SWITCH RESET SWITCH MODE SWITCH GROUND AHEAD DC TO CLOCKS 10 Hz TO CLOCKS GROUND N.O.CONTACT N.O.CONTACT ANTENNA 15V DC IN 1 Hz OUT TO IMPULSE DRIVER TO ANALOG CLOCKS TOP OF HOUR CLOSURE MODEL CT-2002 GPS P art No. 14411 Connect up to 32 serial slav e clocks in Ï dasiy chainÓ configuration. Use twisted pair 24A WG cable (preferrably shielded.) The last clock in chain must be terminated with a 120Ωresistor (or use the termination DIP switch on the CT2002 Lar ge Display.) Serial daisy chain connectivty may also be via CAT-5 cable and RJ-45 conectors. Use a standard 568B ethernet patch cable (all wires conecting straight thru pin to pin) or for custom made cables observe pinouts to right. SERIAL INPUT TERMINATION RJ-45 OUT RJ-45 IN GND +15V DC IN RJ-45 SHIELD TO GND 1 2 3 4 5 6 7 8 9 10 1112131415 1617181920 Ancillary I/O 16- Ground 17- Down Time Closure a t “0” 18- Top-of-Hour Input 19- Ground 20- +15V DC Remote Control 6- Ground 7- Start 8- Stop 9- Reset 10- Mode Clock Triggers 11- Ground 12- Time Closure #1 13- Time Closure #2 14- Time Closure #3 15- Time Closure #4 Serial Synchronizing Data 1- Serial In + 2- Serial In - 3- Ground 4- Serial Out - 5- Serial Out + REMOTE CONTROL BARRIER STRIP PIN-OUTS To additional RJ-45 clock serial inputs. SERIAL INPUT RJ-45 PIN OUTS 1- n/c 2- n/c 3- Serial In + 4- Ground 5- Top-of-Hour Reset Input 6- Serial In - (Note: Make serial connectivity EITHER via twisted or CAT-5 (not both) DB9 (FEMALE) PINOUTS Pin 1- Serial Data Out + Pin 2- Serial Data In + Pin 3- Serial Data In - Pin 4- Serial Data Out - Pin 5- GND Pin 6- TOH Reset Pin 7- GND Pin 8- N/C Pin 9 N/C Make serial connections to any one of the DB9 connector or either RJ-45 connector. SERIAL OUTPUT /LOOP THRU RJ-45 PIN OUTS 1- Serial Out + 2- Serial Out - 3- Serial In + 4- Ground 5- Top-of-Hour Reset Input 6- Serial In - RS-232 to RS-425 long cable run converter (optional) PC Clock Input Sync RS-485 to RS-232 converter RS-232 to RS-485 converter 9 4 8 7 6 3 2 1 5 Note: Software/hardware kit available (Radio Systems part # CT-SYNC) to update Windows PC clocks via USB from the CT-2002 serial data stream OR convert the Windows time base to RS time code to drive and synchronize the CT-2002 system. Logan Township, New Jersey USA 1-856-467-8000 • www .radiosystems.com DOWN TIME CLOSURE AT “0” +9V DC IN GND GND START SW STOP SW RESET SW MODE SW GND SERIAL IN - SERIAL IN + GND TOP OF HOUR RESET INPUT TIME CLOSURE 4 TIME CLOSURE 3 TIME CLOSURE 2 TIME CLOSURE 1 GND SERIAL OUT - (future use) SERIAL OUT + (future use) J4 J6

FOR MASTER TIME SYNC VIA TOP-of-HOUR RESET

wire timer displays Top-of-Hour in for accurate time readout. Note: T.O.H. input must be used to offset timer by one or more seconds. Use IR remote control progam option 10 consult manual page 11 for more information. SERIAL INPUT TERMINATION RJ-45 OUT RJ-45 IN GND +15V DC IN RJ-45 SHIELD TO GND 1 2 3 4 5 6 7 8 9 10 1112131415 1617181920 GND SERIAL OUT - SERIAL OUT + GND START SWITCH STOP SWITCH RESET SWITCH MODE SWITCH GND TIME CLOSURE 1 TIME CLOSURE 2 TIME CLOSURE 3 TIME CLOSURE 4 GND DOWN TIME CLOSURE AT “0” TOH RESET INPUT RJ-45 OUT RJ-45 IN 9V DC IN MODEL CT-2002 DESKTOP Part No. 14409 SERIAL IN + SERIAL IN - RJ-45 SHIELD TO GND Logan Township, New Jersey USA 1-856-467-8000 • www.radiosystems.com CT-2002 4” & 2” or Desktop (Desktop Shown) GND SERIAL OUT - SERIAL OUT + GND START SWITCH STOP SWITCH RESET SWITCH MODE SWITCH GND TIME CLOSURE 1 TIME CLOSURE 2 TIME CLOSURE 3 TIME CLOSURE 4 GND DOWN TIME CLOSURE AT “0” TOH RESET INPUT RJ-45 OUT RJ-45 IN 9V DC IN MODEL CT-2002 DESKTOP Part No. 14409 SERIAL IN + SERIAL IN - RJ-45 SHIELD TO GND Logan Township, New Jersey USA 1-856-467-8000 • www.radiosystems.com CT-2002 4” & 2” or Desktop (Desktop Shown) Ancillary I/O 16- Ground 17- Down Time Closure at “0” 18- Top-of-Hour Input 19- Ground 20- +15V DC Remote Control 6- Ground 7- Start 8- Stop 9- Reset 10- Mode Clock Triggers 11- Ground 12- Time Closure #1 13- Time Closure #2 14- Time Closure #3 15- Time Closure #4 Serial Synchronizing Data 1- Serial In + 2- Serial In - 3- Ground 4- Serial Out - 5- Serial Out + REMOTE CONTROL BARRIER STRIP PIN-OUTS CT-2002 Large FOR MASTER TIME SYNC VIA RADIO SYSTEMS or SMPTE SERIAL DATA wire timer displays serial in with Radio Systems or SMPTE Time-of-Day serial input for accurate time readout. Accurate time will be read by all serially connected displays. Time may be offset by one or more hours - use IR remote control progam option 4 consult manual page 10 for more information. Use a straight thru RJ-45 patch cable (from either RJ-45 connector) if this clock is being fed with remote master time sync and if downstream displays are not required to display remote timer information. Repeat up to 35 displays. Note: final display serial line must be terminated with a 150Ω resisitor (use terminator DIP switch on large clock.) Use a crossover RJ-45 patch cable to slave Time-of-Day and/or timer displays to downstream units. Via the IR remote control enter the program mode and select option 3 for serial time-of-day format. Select “rs1” for time-of-day only re-display from the master clock. Select “rs2” for time-of-day and timer re-display from the master clock. You must use a crossover RJ-45 patch cable if this display is the master (first clock) in the serial chain or, if you want downstream clockcs to display remote timer as well as Time-of-Day PC Clock Input Sync Note: Software/hardware kit available (Radio Systems part # CT-SYNC) to update Windows PC clocks via USB from the CT-2002 serial data stream Radio Systems, Inc. CT2002 Manual Page 20 Serial Clock/Timer Connections between CT2002 stand-alone Models Master/Slave Interconnection via RJ-45 Patch Cable Connections Straight thru (Time-of-Day only) RJ-45 Display Cable. Crossover (Time-of-Day and Timer) RJ-45 Display Cable. RJ-45 Patch Cord Wiring

Radio Systems, Inc.

CT2002 Manual Page 21 Serial Clock/Timer Connections between CT2002 stand-alone Models Master/Slave Interconnection via Twisted Pair Connections FOR MASTER TIME SYNC VIA TOP-of-HOUR RESET wire timer displays Top-of-Hour in for accurate time readout. Note: T.O.H. input must be used to offset timer by one or more seconds. Use IR remote control progam option 10 consult manual page 11 for more information. FOR MASTER TIME SYNC VIA RADIO SYSTEMS or SMPTE SERIAL DATA wire timer displays serial in with Radio Systems or SMPTE Time-of-Day serial input for accurate time readout. Accurate time will be read by all serially connected displays. Time may be offset by one or more hours - use IR remote control progam option 4 consult manual page 10 for more information. CT-2002 4” & 2”, Desktop or Thin (Thin Shown) GND SERIAL OUT - SERIAL OUT + GND START SWITCH STOP SWITCH RESET SWITCH MODE SWITCH GND TIME CLOSURE 1 TIME CLOSURE 2 TIME CLOSURE 3 TIME CLOSURE 4 GND DOWN TIME CLOSURE AT “0” TOH RESET INPUT RJ-45 OUT RJ-45 IN 9V DC IN MODEL CT-2002 DESKTOP Part No. 14409 SERIAL IN + SERIAL IN - RJ-45 SHIELD TO GND Logan Township, New Jersey USA 1-856-467-8000 • www.radiosystems.com CT-2002 Desktop GND SERIAL OUT - SERIAL OUT + GND START SWITCH STOP SWITCH RESET SWITCH MODE SWITCH GND TIME CLOSURE 1 TIME CLOSURE 2 TIME CLOSURE 3 TIME CLOSURE 4 GND DOWN TIME CLOSURE AT “0” TOH RESET INPUT RJ-45 OUT RJ-45 IN 9V DC IN MODEL CT-2002 DESKTOP Part No. 14409 SERIAL IN + SERIAL IN - RJ-45 SHIELD TO GND Logan Township, New Jersey USA 1-856-467-8000 • www.radiosystems.com CT-2002 4” & 2”, Desktop or Thin (Desktop Shown) Connect serial inputs in parallel to slave downstreamTime-of- Day displays only. Connect serial output to downstream clocks’ serial input to slave Time-of-Day and timer readouts, or if this is the master (first) clock in the serial chain. Connect serial inputs in parallel to slave downstreamTime-of- Day displays only. Repeat up to 35 displays. Note: final display serial line must be terminated with a 150Ω resisitor (use terminator DIP switch on large clock.) Connect serial output to downstream clocks’ serial input to slave Time-of-Day and timer readouts, or if this is the master (first) clock in the serial chain. PC Clock Input Sync Note: Software/hardware kit available (Radio Systems part # CT-SYNC) to update Windows PC clocks via USB from the CT-2002 serial data stream DOWN TIME CLOSURE AT “0” +9V DC IN GND GND START SW STOP SW RESET SW MODE SW GND SERIAL IN - SERIAL IN + GND TOP OF HOUR RESET INPUT TIME CLOSURE 4 TIME CLOSURE 3 TIME CLOSURE 2 TIME CLOSURE 1 GND SERIAL OUT - (future use) SERIAL OUT + (future use) J4 J6

Radio Systems, Inc.

CT2002 Manual Page 22 Connection Diagrams CT-2002 GPS Antenna Wiring Options CT-2002 GPS Driver 1 2 3 4 5 6 7 8 12345678 DIP SWITCHES (UP IS ON) ANTENNA 15V DC IN MODEL CT-2002 GPS Part No. 14411 Logan Township, New Jersey USA 1-856-467-8000 • www.radiosystems.com CT-2002 GPS Driver 1 2 3 4 5 6 7 8 12345678 DIP SWITCHES (UP IS ON) ANTENNA 15V DC IN MODEL CT-2002 GPS Part No. 14411 Logan Township, New Jersey USA 1-856-467-8000 • www.radiosystems.com CT-2002 GPS Driver 1 2 3 4 5 6 7 8 12345678 DIP SWITCHES (UP IS ON) ANTENNA 15V DC IN MODEL CT-2002 GPS Part No. 14411 Logan Township, New Jersey USA 1-856-467-8000 • www.radiosystems.com Satellite Receiver Antenna Note: The cable used must be shielded with the ground connected to pin 1 on both ends. For cable lengths over 150', install Radio Systems RS-485 balancing amplifiers. Pin 1 = Ground & Shield Pin 2 = +15V Pin 4 = 1 P.P.S. Pin 6 = Data 87654321 RJ-45 Patch Cable 250' factory shielded cable or user provided shielded 4 conductor cable up to 500' Note- Shielded Cable may be shortened, but not spliced longer. From Antenna To Cable To Clock From Cable RS-485 to RS-232 RS232 to RS-485 RJ-11 RJ-11 I. -with user provided cable II. -with factory 150' extension cable III. -with RS-485 converter box (for cable runs over 150' and up to 1000') Satellite Receiver Antenna Satellite Receiver Antenna up to 150' Shielded Cable Note: (on white-bodied antennas) yellow, black and ground wires shorted at connector RJ-45 Patch Cable

Radio Systems, Inc.

CT-2002 Manual Page 23 Connection Diagrams CT-2002 GPS Dip Switch Settings India (New Delhi) Time 5 1/2 hours ahead of GMT (No Daylight Savings/12 hour/ Analog Clocks connected) Note: Special software prom p/n 16119 required. Prom adds 1/2 hour to all time offset settings.

Radio Systems, Inc.

CT-2002 Manual Page 24 Warranty Radio Systems, Inc., warrants this equipment to be free from defects in materials and workmanship for a period of one (1) year. This warranty extends to first users of the product and future owners who pur- chase the product within the warranty period. The terms of this warranty are null and void if this product is stored or operated in an environment not conducive to electronic equipment, or shows signs of misuse or modifications which affect the proper functioning of the product. This warranty does not apply to damage caused by fire, smoke, flood, lightning, or acts of nature and physical abuse. Radio Systems, Inc., and its associated companies, authorized distributors, and personnel are not liable for loss of revenues or other damages, or effects to the broadcast signal quality or coverage which may result from the from the improper functioning of this product. Repair Policy Technical assistance is available at any time, at no charge, by phone or corre- spondence. During the warranty period, there will be no charge for parts or service made to units which show no sign of misuse by customer or lightning caused damage. The customer is responsible for the cost of shipping their unit back to Radio Systems for repair. During the warranty period, shipment of small parts and assemblies may also be made at a charge to the user. Emergency shipments of replacement parts and cir- cuits will be made at the user’s request for an extra shipping and service charge. Chargeable services will be made COD or on Net-30 day terms to users with established accounts. During the warranty period, full credit or return of COD charges (less any service and expedited shipping charges) will be made to users who return the defective parts or circuits within 30 days, if the damage is covered under the terms of the warranty. Return Instructions Contact Radio Systems for a return authorization number. Pack all items carefully and ship prepaid, via UPS insured, to: Radio Systems, Inc. Attn: R.A. # __________ 601 Heron Drive Logan Township, New Jersey 08085-1741 Enclose a note which includes your name, company, phone number, the serial number, return address (no box numbers), and a complete description of the . problem.

(856) 467-8000 • Fax (856) 467-3044.

601 Heron Drive • Logan Township, New Jersey 08085 • www.radiosystems.com For Assy. Part # 14691 rev. 9/09