Radio Systems CT-2002 Manual
Read Online
Read the Radio Systems CT-2002 Manual online using the built-in PDF viewer.
Text of the manual
Radio Systems, Inc.
CT-2002 Clock/Timer Manual
For Models:
CT-2002 Desktop
CT-2002 Thin
CT-2002 Large 2”
CT-2002 Large 4”
CT-2002 Console
CT-2002 Desktop GPS
CT-2002 2” GPS
CT-SYNC Clock to PC Synchronization Kit
GPS-SYNC GPS to PC Synchronization Kit
*Updated SEPTEMBER 2008
Applies to units with
software versions CT-2007
Includes Remote Control Enhancements
& New Daylight Savings Time Schedule
Radio Systems, Inc.
CT-2002Manual
TOC
Contents
General Description
Models......................................................................................................4
Options.....................................................................................................4
General Operating Instructions
Clock/Timer (Mode) Select........................................................................5
To Set the Clock........................................................................................5
To Use the Up Timer.................................................................................5
To Utilize as Slave Clock Display.............................................................6
To Utilize as Slave Timer Display.............................................................7
Time-of-Day Offset....................................................................................8
Infrared Remote Control
Up Timing.................................................................................................9
Down Timing............................................................................................9
Storing Down Times..................................................................................9
Recalling Stored Down Times.................................................................10
On Power Up..........................................................................................10
Time-of-Day Set......................................................................................10
Setting to Slave Display...........................................................................10
Setup Functions.......................................................................................11
Infrared Remote Control Diagram...........................................................13
GPS Driver
Additional Operating Instructions............................................................14
Setup Programming.................................................................................14
Top-of-Hour Closure...............................................................................14.
Connections and Installation...................................................................14
Operation................................................................................................15
GPS Error Codes......................................................................................15
Radio Systems, Inc.
CT-2002 Manual
TOC
Synchronization and GPS Extender Kits
PC Synchronization.................................................................................16
GPS Antenna Cable Extenders ................................................................17
Wiring and Programming Diagrams
Remote Connections to the CT-2002 Clock/Timer..................................18
Serial Time-of-Day Connections from CT-2002 GPS or Master Models...19
Serial Clock Timer Connections between CT-2002 Stand Alone Models 20.
Using RJ-45 Patch Cords
Serial Clock Timer Connections between CT-2002 Stand Alone Models 21.
Using Twisted Pair Wiring
GPS Antenna Wiring Diagrams...............................................................22
CT-2002 GPS Dip Switch Settings Diagram............................................23
Policies
Warranty.................................................................................................24
Repair Policy...........................................................................................24
Return Instructions..................................................................................24
Note:
Master Desktop and Master 2” models are no longer manufactured.
Analog clocks are no longer manufactured.
For operating and connection information for these products consult
www.radiosystems.com/technotes.html
Radio Systems, Inc.
CT-2002 Manual
Page
General Description
The CT-2002 series of digital clock/timers is a family of timing displays, a master
driver and a GPS driver.
Models
All Display Models:
Will accept serial Time-of-Day and timer data in
Radio Systems format, or Time-of-Day (only) data in
SMPTE format. Provides up-timing as standard and
down-timing with the optional IR remote control.
Each display model (with V2005 or higher software)
will output serial data for Time-of-Day in Radio
Systems format.
CT-2002 Desktop
4” deep x 3” high Desktop clock/up-down timer with
3/4” LED displays which functions as a stand alone or
slave time of day display with wired remote control.
CT-2002 Thin
1” deep x 3” high “stick-on” clock/timer with 3/4”
LED displays featuring the same functions as the
desktop unit, but in a smaller profile cabinet.
CT-2002 2”
2” deep x 5” high clock/timer display with 2” high
LED display and the same features set as the .
“desktop” and “thin” units.
CT-2002 4”
2” deep x 5” high clock/timer display with 4” high
LED display and the same features set as the .
“desktop” and “thin” units.
Master & GPS Models:
Provide up-timing and output serial Time-of-Day data
in Radio Systems format.
Options
Infra-Red Remote Control
Required for down timing and internal setup func-
tions. Also provides clock operation, Time-of-Day
Set and up-timer functions (for display units only.)
Included with Desktop & Large Display.
RS-485 Converter
Installs in-line between the GPS satellite antenna and
clock/receiver. Required for cable runs in excess of
150’.
Radio Systems, Inc.
CT-2002 Manual
Page 5
General Operating Instructions
For all non GPS or master units (applies to units utilized in stand-alone
and slave display capacities.)
Time-of-Day Set Up and Up-Timer functions can be controlled by the front panel
buttons or the wired remote control. However, the IR Remote Control must be
used for entering down times and internal setup functions.
Front Panel or Wired Remote Operation
Clock/Timer (Mode) Select
All CT-2002 units operate as both clocks and timers. Switch between modes by
pressing the MODE button on the front of the unit. The front panel LED’s will light
to indicate the mode selected.
Note that on the CT-2002 large wall display models, the mode switch is available
on the remote control only. The fourth front panel switch is used to put the clock
into the set mode.
To Set the Clock:
Note: If Serial Time of Day is supplied to the CT-2002 (slave mode), it will not
be possible to enter the Time-of-Day set mode. Setting the time-of-day can either
be done at the master unit or the displayed hours can be offset via the IR Remote
Control.
1. Press the mode button to select the Time-of-Day display. The Clock LED will
illuminate.
2. (Desktop and Thin models) - press and hold the STOP and START buttons.
The Set LED will illuminate..
(Large models) - press the SET button. The Set LED will illuminate.
3. Display resets to 12:00:00
4. Press the STOP button to advance the hours. Press the RESET button to
advance the minutes (note - seconds are not setable and remain at :00).
5.
Start the clock at the top of the minute by pressing the START button. .
The Set LED will extinguish.
To Use the Up Timer:
(To utilize as a Down-TImer consult IR Remote Control Instructions page 8)
1. Press the Mode Button to select the timer display. The Timer LED will .
illuminate.
2. Press the START button to start timing.
3.
Press the STOP button to stop timing.
4. Press the RESET button to return the display to 00:00.
Radio Systems, Inc.
CT-2002 Manual
Page 6
Slaved Displays
To Utilize as a Slaved Clock Display (CT-2002 Display units only):
1. Consult page 10 for setup functions to select either RS or SMPTE sync format.
2.
Provide serial data to the unit. Choices of serial data are SMPTE time code
and Radio Systems Time-of-Day data from CT-2002 GPS or CT-2002 Master
units. In addition a CT-2002 display unit can be used to provide Time-of-Day
and Timer data in the Radio Systems format. To connect to slave Time-of-
Day displays only, wire only the serial data input terminals in parallel (use
either the terminal strip or RJ-45 connectors—see the connections diagram
on page 22).
3.
The “SYNC” front panel LED will light and the time-of-day will immediately
synchronize to the master unit readout.
4.
Time-of-Day setting is now no longer available on this slave display. Time-of-
Day setting must be made to the unit providing the serial Time-of-Day data.
5.
If the data link is lost, the clock will revert to stand-alone local operation and
the sync LED will extinguish.
6.
Local timer functions continue to be available as described on the preceding
page.
7.
The minutes and seconds may be offset from the top of hour input closure.
See manual section “Time-of-Day Offset on page 8 and “IR Remote control”
section.
8.
The hour, minutes and seconds may be offset from the upstream time-of-day
serial data via the infra-red remote control. See manual section “Time-of-Day
Offset on page 8 and “IR Remote control” section.
Note: software/hardware kit is available (Radio Systems part # CT-SYNC) to
update Windows PC clocks from your CT-2002 serial data stream
Radio Systems, Inc.
CT2002 Manual
Page
To Utilize as a Slaved Timer Display as well as a slaved clock dis-
play. (CT-2002 Display units only):
1.
Consult page 11 for Setup function programming, and choose selection .
3 option “RS2” for slave timer operation.
2.
Provide serial data from any CT-2002 display unit whose timer display you
want to slave. Connect the serial data output terminals of the up-stream .
CT-2002 display to the serial data input terminals of the slave display. Use
either terminal strip or RJ-45 connectivity (consult wiring diagram on page 20
& 21.)
3.
Place the slave display in the clock mode and confirm that the “SYNC” front
panel LED on the slave display is lit and that the slave displays shows the
Time-of-Day from the up-stream unit.
4.
In the “Clock” mode, the time-of-day on the slave display will now synchro-
nize to the up-stream stand alone display (regardless of what mode is being .
displayed on the stand-alone upstream display.)
5.
Place the slave display in the timer mode and press the “MEM 6” button on
the IR remote control. Confirm that the SYNC LED on the slave lights and
that the slave display shows the timer data from the up-stream display unit.
6.
To return the slave display to none-slaving timer (stand-alone) functionality,
press the “RESET” button on the IR remote control with the slave display in
the timer mode. The “SYNC” LED will extinguish and the timer display will
reset to 00:00, allowing local (IR and parallel) timer control.
7.
To return to slave timer operation, push the “MEM 6” button on the IR
remote control with the slave display in the timer mode. The “SYNC” LED
will (re)illuminate and the display will synchronize to the up-stream stand-
alone timer display.
8.
Additional timers “downstream” from this slave timer may be wired to slave
to this timers display, or function as Time-of-Day displays and independent
stand-alone timer displays. Consult the wiring diagram on page 20 (RJ-45
patch cord wiring) or 21 (twisted pair wiring) for specific wiring configura-
tions.
Wired Remote Control
All front panel controls are available on the rear barrier strip connector.
Contacts are momentary / pull-to-ground.
See attached wiring diagram for connections - page 18.
Radio Systems, Inc.
CT2002 Manual
Page
Time of Day Display Offset
The time of day displayed on CT2002 displays slaved from upstream GPS or
Master clocks or triggered by top-of-hour input closures can be offset by any
amount of seconds, minutes, or hours. Typical applications ofr such an offset:
•Network Top-of-hour pulses sent early (seconds before the .
actual top-of-hour) .
• Stations running in full obsentity delay.
• HD station transmission delay.
• Time zone multi clock displays
To offset closure reset:
Use the infrared remote control option 10 position to enter the minutes and
or seconds desired to be displayed when the top of hour closure is received..
• Note that hours displayed will not be affected. .
• Note that top-of-hour is only active prior to and after the hour (to avoid
false triggers at other times)..
• See manual page 12 for programming instructions.
To offset serial time input from and upstream GPS or Master
clock in the serial chain (RS serial time code or SMTPE time code
allowed):
Use the infra red remote control to input hours to be added to time of day
serial data (option 4), or minutes and or seconds to be added to the time of
day serial data (option 11)..
• Note that offsets are always added to the stream. For example:.
To offset plus 1 hour, 10 seconds - set option 4 for 01 and .
option 11 for 00:10.
To offset minus 8 seconds - set option 4 for 23 and .
option 11 for 00:52
Radio Systems, Inc.
CT-2002 Manual
Page 9
Infra Red Remote Control
(CT-2002 Display units only)
Up Timing
1
Press the Timer Button to place the CT-2002 into the Timer Mode. The Timer
LED will illuminate.
(If the “Down” LED is illuminated, press the Reset Button. It may require two
presses.)
2.
Press the Start Button to start up timing.
3.
Press the Stop Button to stop up timing.
4.
Press the Start Button to resume up timing.
5.
Press the Reset Button to clear the display.
Down Timing
1.
Press the Timer Button. The Timer LED will illuminate.
2.
Using the numeric keypad, enter a down time. The Set LED and Down LED
will illuminate. Hours can be from 00 to 99, minutes from 00 to 59 and sec-
onds from 00 to 59. Erroneous entries can be overwritten or the Reset Button
can be used to zero the display. An invalid time such as 12:60:00 will be
cleared when the Start Button is pressed.
3.
Press the Start Button to begin down timing. (The down timer can be set
to either stop at zero or continue to count negative. See IR Remote Setup
Functions - see page 10.)
4.
Press the Stop Button to stop down timing.
5.
Press the Start Button to resume down timing.
6.
Press the Reset Button once to recall the entered down time. Repeat steps 3
through 6 as desired.
7.
Press the Reset Button two times to exit the down mode (and to clear the .
display and return to up timing mode).
Storing Down Times
The IR Remote Control can be used to store up to six down times. These times are
saved when power is removed from the CT-2002.
1.
Press the Timer Button. The Timer LED will illuminate.
2.
Using the numeric keypad, enter a down time. The Set LED and Down LED
will illuminate. Hours may be from 00 to 99, minutes from 00 to 59, and sec-
onds from 00 to 59. Erroneous entries can be overwritten or the Reset button
can be used to zero the display.
3.
Press one of the Store Buttons. If the time entered was valid, the display will
momentarily flash, the Set LED will extinguish and the down time will be
stored. In addition, the entered down time will remain on the display and
the Down LED will remain illuminated. However, an invalid time (such as
12:60:00) will be cleared when a Store Button is pressed. In addition, the .
CT-2002 will return to the Up Timer Mode.
4.
Repeat steps 2 and 3 as desired.
Radio Systems, Inc.
CT-2002 Manual
Page 10
Recalling Stored Down Times
Previously stored down times in locations MEM1 thru MEM6 may be recalled
either with the IR remote control or via the wired remote control. See connection
diagram page 18.
1.
Press the Timer Button. The Timer LED will illuminate.
2.
Press one of the Store Buttons.
3.
The stored down time will appear on the display. The Down LED will illumi-
nate.
4.
Press the Start Button to begin down timing.
5.
Press the Stop Button to stop down timing.
6.
Press the Start Button to resume down timing.
7.
Press the Reset Button once to recall the selected down time. Repeat steps 3
through 6 as desired.
8.
Press the Reset Button two times to exit the down mode (return to up timing
mode) and clear the display.
On Power up
1.
Units always power up into the time-of-day mode.
2.
If serial data (RS or SMPTE) is supplied (and the correct mode was pre-select-
ed with the IR Remote Control), then the serially supplied time will display.
3.
The clock must be set when using the internal clock base.
Time-of-Day set
The CT-2002 will not enter the Time-of-Day set mode if serial time of day is being
supplied by a master clock or GPS system. However, the displayed time may be
offset up to 23 hours, (see IR Remote Setup Functions - page 13).
1.
Press the Clock Mode Button to put the CT-2002 into the Clock Mode. .
The Clock LED will illuminate.
2.
Press the Time-of-Day set button. The Set LED will illuminate.
3.
Using the numeric keypad on the IR Remote Control enter the correct time.
The display will advance to the next digit only if a valid time has been
entered. In the event of an erroneous entry, press the Time-of-Day set button
to start over.
4.
Press start at the correct moment.
Setting the Timer to Act as a Slave Display
Timers can be wired to slave the display of an upstream timer. Consult wiring dia-
gram on pages 20 & 21for details.
1. When in timer mode, press the MEM 6 button on the IR remote control. The
“SYNC” LED will illuminate and the timer will display the upstream time .
(the slave display must be receiving timer data from and up-stream timer, and
RS2 must be selected in IR setup option three.)
2. Press the Reset Button “when in timer mode” to force the timer to operate as
a local up/down timer. The “SYNC” LED will extinguish and the timer dis-
play will reset to 00:00. Operate the timer as usual.
3. Press the “MEM 6” button on the IR Remote Control to revert to slave timer
readout.
Radio Systems, Inc.
CT-2002 Manual
Page 11
Setup Functions
The IR Remote Control is used to set various functions of the CT-2002. With the
exception of “IR Remote Disable” these selections are stored if power is lost.
1.
Press the Program Button. The “PGM” LED will illuminate. Repeatedly press-
ing the Setup Button will step the CT-2002 through the 10 menu choices.
2.
The selections are changed either by pressing the “Clock” set button or using
the numeric keypad.
3.
The Setup Mode is exited (and the selections are stored) by pressing either
the Clock Button or the Timer Button.
4.
For a confidence check that your programming changes have been made and
stored, cycle thru the setup functions without making any more changes to
check that your entries are saved. Then press clock or timer to exist.
Option 1:
12/24 hour clock operation. Press the “Clock” set .
button to toggle between 12 and 24 hour operation.
Option 2:
Down timer stop at zero or count negative. Press the .
Time-of-Day set button to toggle between hold at 0 or go
negative.
Option 3:
Serial time of day format. Press the “Clock” set button to
toggle between Radio Systems-1 (rS1) format, Radio Systems-2
(rS2) format and SMPTE (SP) format .
“SMPTE” enable the serial input to read standard SMPTE .
format (no drop frame ).
“rS1” enables the serial inputs to read Radio Systems serial
time of day format as generated by Radio Systems’ GPS,
Master, and stand-alone clocks.
“rS2” enables the serial inputs to read Radio Systems serial
time of day format as well as upstream timer displays. Note
that in this mode, the “Mem 6” and RESET keys on the IR
Remote control is retasked to allow switching between slave
and local timer functions.
Option 4:
Serial time of day hour offset. Press the “Clock” set button to
select from 00 to 23 hour added to the serial time of day data.
Use option 11 to input minutes and seconds added.
Option 5:
IR Remote Functionality. Press the “Clock” set button to
toggle between full functionality (iron), program defeat
(irPr), and no remote (irno).
In program defeat (irPr) the setup functions are locked out.
When AC power is toggled off and on, the remote returns to
full functionality.
In no remote (irno) all remote functions are ignored. When
AC power is toggled off and on, the remote returns to full
functionality. Use this function if there is more than one
clock in use in the same room.
Radio Systems, Inc.
CT2002 Manual
Page 12
Option 6:
Time compare 1. Use the numeric keypad to enter the
minutes and seconds of the time compare. Time between
00:00 and 59:59 must be entered. Note that all four dig-
its (including leading zeros) must be entered. When the
minutes and seconds of the time of day are equal to the
time compare stored, the matching open collector wired
remote will activate.
Option 7:
Time compare 2. See “option 6” above.
Option 8:
Time compare 3. See “option 6” above.
Option 9:
Time compare 4. See “option 6” above.
Option 10:
Top of Hour Reset Offset. A wired remote input is .
available for top of hour reset. The default operation .
is to reset the time-of-day to 00 min’s. & 00 sec’s. .
Use the numeric keypad to reset to a different time, .
(minutes and seconds). When the displayed time of day is
within a +- 5 minute window of the stored top of hour time
and the wired remote input is activated, the displayed
time will be replaced by the stored top of hour time. (This
function active for stand-alone time-of-day operation
only.)
Option 11:
Serial time of day minutes and seconds offset. Use the
numeric keypad to enter the minutes and seconds desired to
be added to the serial time of day data. Use option 4 to input
hours to be added.
Radio Systems, Inc.
CT-2002 Manual
Page 13
RESET
STOP
START
CLOCK
TIMER
CLOCK SET
PROGRAM
1
2
3
4
5
6
7
8
9
0
MEM 1
MEM 2
MEM 3
MEM 4
MEM 5
MEM 6
Storing Down Times
1.
Press the Timer Button.
The Timer LED will illuminate.
2. Using the numeric keypad, enter a down
time. The Set LED and Down LED will illumi-
nate. Hours may be from 00 to 99, minutes
from 00 to 59, and seconds from 00 to 59.
Erroneous entries can be overwritten or the
Reset button can be used to zero the display.
3. Press one of the Store Buttons. If the time
entered was valid, the display will momen-
tarily flash, the Set LED will extinguish and
the down time will be stored. In addition, the
entered down time will remain on the display
and the Down LED will remain illuminated.
However, an invalid time (such as 12:60:00)
will be cleared when a Store Button is
pressed. In addition, the CT-2002 will return
to the Up Timer Mode.
4. Repeat steps 2 and 3 as desired.
Recalling Stored Down Times
1.
Press the Timer Button.
The Timer LED will illuminate.
2. Press one of the Store Buttons.
3. The stored down time will appear on the
display. The Down LED will illuminate.
4. Press the Start Button to begin down timing.
5. Press the Stop Button to stop down timing.
6. Press the Start Button to resume down timing.
7. Press the Reset Button once to recall the
selected down time. Repeat steps 3 through 6
as desired.
8. Press the Reset Button two times to exit the
down mode (return to up timing mode) and
clear the display
Note: Stored Down-Time 1 can be recalled
remotely via parallel remote control wiring.
See illustration page 18.
Push to display
Time-of-Day
Push to freeze
Timer Display
When Up-Timing:
Push once to reset timing to 00:00 .
(Continues to run if reset from Stop) .
(Holds if reset from Stop)
When Down-Timing:
Push once to redisplay down time..
Push again to return display to 00:00 .
and Up-Time mode.
In Clock Mode:
Starts display running from .
Time-of-Day set mode
In Timer Mode:
Starts display running from .
Up or Down Timer display
Push for Timer Mode
Push to set Time-of-Day
Enter via numeric keypad.
Push start.
Push to set Internal Programming fea-
tures (see setup functions on page 10).
Program functions via .
numeric keypad.
Push Timer or Clock to exit .
in that mode
To set down time
Enter time via numeric keypad.
Push start to begin.
Push reset to recall downtime.
Push reset 2x to exit.
CT-2002 InfraRed Remote Control
MEM 6 is retasked to switch the
timer between slave and local
modes when using associated dis-
play as a remote timer. See page 7.
Radio Systems, Inc.
CT-2002 Manual
Page 14
GPS Driver
Additional Operating Instructions
Setup Programming
Refer to the dip-switch setting diagram on page 23 to program the hour offset from
GMT for your time zone, to enable the automatic daylight savings time setting,
and to enable 12 or 24 hour operation.
Note that the unit is shipped with the factory default setting of Eastern Time Zone (5
hours behind GMT), auto daylight savings time switch-over and 12-hour operation.
The analog clock dip-switch (switch #1) causes the display to flash after recovery
from a satellite signal loss as an operator indication that your analog clocks have
lost time and must be reset. (Digital clocks connected to the GPS Master driver
will automatically update.) After adjusting the time on the analog clock (see ana-
log clock operation), push the start button to cease flashing and resume normal
display. Factory default for this feature is “off”.
Top-of-Hour Closure
GPS Master driver units (on 2”, 4” and desktop) provide a top-of-hour closure
available as a C-form relay closure for 250 ms, occurring at the top of each hour.
The C-form contacts are available on the rear remote control barrier strip .
connector on pins 15 and 16 (last two terminals on the strip). See Remote
Connection diagram p19 of this manual for connections.
Connections and Installation
1. Mount the antenna on a roof or window ledge with a clear view of the sky.
Avoid areas directly under microwave antenna paths, or near dense foliage.
2. The antenna plugs into the clock/receiver via a pre-installed RJ-45 Ethernet
style connector. Up to 150’ of four conductor shielded cable may installed
between the antenna and the receiver. This cable may be user provided, or a
pre-assembled 150’ or 250’ extension cable is available from Radio Systems.
Please note that for any cable run in excess of 150’, in-line balancing RS-485
convertor amplifiers, available from Radio Systems, must be installed. For
wiring specifications, see the attached antenna wiring detail on page 23.
Radio Systems, Inc.
CT-2002 Manual
Page 15
Operation
1. After all connections are made, apply power. The unit will take from 1 to 15
minutes to acquire the satellite data. During this initial acquisition period,
and during any subsequent periods of satellite data loss, the GPS Master unit
will display one of 5 error codes. These codes and their meanings are listed
below.
2. After acquisition, the true time will display and will be serially relayed to any
digital display units “downstream”. If data is lost at any time in the future,
downstream display “data” lamps will extinguish, but these clocks will con-
tinue to run on their internal time base. On satellite reacquisition, the time
will be updated, and the “data” lamps re-illuminated.
3. Front panel master GPS controls cannot be used to set or change the digitally
displayed time-of-day, but the time mode may be used to adjust the time on
any analog clocks connected, and the START, STOP and RESET switches may
be used in the timer mode. See the “Analog Clock Connection and Use” sec-
tion for operating details.
GPS Error Codes
These two digit error codes will display in the GPS Master readout in the center
two digits on unit turn-on (pre-satellite acquisition) and during any data outage.
Error Code
1-Pulse Per Second
Serial Data
Data
01 (1 PPS line broken)
not present
present
okay
02 (satellite acquisition lost)
present
present
bad
03 (fire-up status - first 1 to 15 minutes) not present
present
bad
04 (corrupted serial data output)
present
not present
bad
05 (no antenna connection)
not present
not present
bad
GPS-SYNC Synchronization Kit
This hardware and software kit allows time code received directly from GPS
antenna to be read into a PC COMM (RS232 serial) port..
The kit includes an antenna, antenna outdoor mount, 12ft. connectorized serial
cable, power supply and interface box, and software. A 150ft. extension cable is
available as well as RS-485 for extended cable runs up to 500ft.
Included software installs in any Windows 2000 or higher OS and automatically
updates the Windows time base with GPS accurate time. Hours, minutes and sec-
onds offset can be set manually by software configuration screens.
PC-SYNC Synchronization Kit
This hardware and software kit allows a PC’s time base to be updated via RS serial
time code, OR allows a PC’s time base to output RS serial time code. Connection
to the PC is via USB and connection to CT-2002 is via two wire twisted pair serial
cable..
The kit includes a USB to RS422 converter and software.
One included software program installs in any Windows 2000 or higher OS and
automatically updates the Windows time base with CT-2002 serial time. A second
software program included installs in any Windows 2000 or higher OS and auto-
matically updates the CT-2002 clock system from the PC time base.
Hours, minutes and seconds offset can be set manually via the software .
configuration screens or in the CT-2002 software.
Radio Systems, Inc.
CT-2002 Manual
Page 16
To/from RS serial .
clock time code .
via two wire .
RS222 connection
Radio Systems, Inc.
CT-2002 Manual
Page 17
GPS Antenna Cable Extension
CT-150 GPS - 150ft. Extension Cable
150ft. of shielded CAT-5 cable with “biscuit” style RJ-45 termination boxes at
each end. GPS antenna plugs into far side and near is connected to GPS clock via
an RJ-45 patch cable (provided.)
Note: This cable may be shortened by the customer, but 150ft. is the maximum
distance that the antenna cable may be extended without the use of the active RS-
485 converter boxes (below.)
CT-250 GPS - 250ft. Active Extension Kit
250ft. of shielded CAT-5 cable with active RS-232 to RS-485 extender ‘biscuits”.
GPS antenna plugs into far side and near is connected to GPS clock via an RJ-45
patch cable (provided.) Converter biscuits are active and powered via the GPS
clock power supply.
Note: The antenna side RS-232 converter is not in a water-proof box and must be
housed indoors or in a protective closure.
Radio Systems, Inc.
CT2002 Manual
Page 18
Remote Control Connections to CT-2002 Clock/Timer Models
GND
SERIAL OUT -
SERIAL OUT +
GND
START SWITCH
STOP SWITCH
RESET SWITCH
MODE SWITCH
GND
TIME CLOSURE 1
TIME CLOSURE 2
TIME CLOSURE 3
TIME CLOSURE 4
GND
DOWN TIME CLOSURE AT “0”
TOH RESET INPUT
RJ-45 OUT
RJ-45 IN
9V DC IN
MODEL CT-2002 DESKTOP Part No. 14409
SERIAL IN +
SERIAL IN -
RJ-45 SHIELD TO GND
Logan Township, New Jersey USA
1-856-467-8000 • www.radiosystems.com
CT-2002 Desktop
START
TOH RESET
STOP
RESET
MODE
Time Closures
Pull to Ground
Ground on Timer Remote rrier Stri
GROD
se or
oter ener l
urose
sinl diodes
se n enerl urose
SPST momentrt us
utton or to
StudioHu T nels
Position in timer mode MEM 1
MEM 2
MEM 3
MEM 4
MEM 5
MEM 6
Position in timer mode
Position in timer mode
Position in timer mode
Position in timer mode
Position in timer mode
CT-20022
Connetions
to Timer Remote
rrier Stri
STOP
RESET
MODE
START
START
START
STOP
STOP
START
RESET
MODE
MODE
MODE
MODE
o ee stoe eo postos t e eote
e to eote tes so o Desktop oes
ote tt stee oes ot sppe st e ste
GND
+15V DC IN
1 2 3 4 5
6 7 8 9 10
1112131415
1617181920
Anciary
16- Ground
17- Down Time Closure at “0”
18- Top-of-Hour Input
19- Ground
20- +15V DC
emote ont ro
6- Ground
7- Start
8- Stop
9- Reset
10- Mode
oc Triggers
11- Ground
12- Time Closure #1
13- Time Closure #2
14- Time Closure #3
15- Time Closure #4
Seria Synchroniing ata
1- Serial In +
2- Serial In -
3- Ground
4- Serial Out -
5- Serial Out +
T NTL A ST N-UTS
TOH RESET
STOP
RESET
MODE
Time Closures
ull to round
START
GRO D
1 2 3 4 5 6 7 8
A CK
DIP SWITCHES
UP IS ON
SERIAL DATA OUT +
SERIAL DATA OUT -
GROUND
START SWITCH
STOP SWITCH
RESET SWITCH
MODE SWITCH
GROUND
AHEAD
DC TO CLOCKS
10 H TO CLOCKS
GROUND
COMMON
N. O. CONTACT
ANTENNA
15V DC IN
1 H OUT
TO
IMPULSE
DRIVER
TO
ANALOG
CLOCKS
TOP
O HOUR
CLOSURE
MODEL CT-2002 GPS Part No. 14411
CT-2002
START
TOP O HO R
REA COSRE
STOP
RESET
MODE
Logan Township, New Jersey USA
1-856-467-8000 • www.radiosystems.com
CT-2002
START
TOH RESET
STOP
RESET
MODE
Time Closures
ull to round
DOWN TIME CLOSURE AT “0”
GND
TOP O HOUR RESET INPU T
TIME CLOSURE 4
TIME CLOSURE 3
TIME CLOSURE 2
TIME CLOSURE 1
GND
SERIAL OUT -
SERIAL OUT +
+9V DC IN
GND
GND
START SW
STOP SW
RESET SW
MODE SW
GND
SERIAL IN -
SERIAL IN +
4
6
Radio Systems, Inc.
CT2002 Manual
Page 19
Serial Time of Day Connections from CT2002 and GPS Models
Note: software/hardware kit is available (Radio Systems part # CT-SYNC)
to update Windows PC clocks from your CT-2002 serial data stream
GND
SERIAL OUT -
SERIAL OUT +
GND
START SWITCH
STOP SWITCH
RESET SWITCH
MODE SWITCH
GND
TIME CLOSURE 1
TIME CLOSURE 2
TIME CLOSURE 3
TIME CLOSURE 4
GND
DOWN TIME CLOSURE AT “0”
TOH RESET INPUT
RJ-45 OUT
RJ-45 IN
9V DC IN
MODEL CT-2002 DESKTOP P art No. 14409
SERIAL IN +
SERIAL IN -
RJ-45 SHIELD TO GND
Logan Township, New Jersey USA
1-856-467-8000 • www .radiosystems.com
1 2 3 4 5 6 7 8
BACK
DIP SWITCHES
(UP IS ON)
SERIAL DA TA OUT +
SERIAL DA TA OUT -
GROUND
START SWITCH
STOP SWITCH
RESET SWITCH
MODE SWITCH
GROUND
AHEAD
DC TO CLOCKS
10 Hz TO CLOCKS
GROUND
N.O.CONTACT
N.O.CONTACT
ANTENNA
15V DC IN
1 Hz OUT
TO
IMPULSE
DRIVER
TO
ANALOG
CLOCKS
TOP
OF HOUR
CLOSURE
MODEL CT-2002 GPS P art No. 14411
Connect up to 32 serial slav e clocks in Ï dasiy chainÓ
configuration. Use twisted pair 24A WG cable
(preferrably shielded.) The last clock in chain must be
terminated with a 120Ωresistor (or use the termination
DIP switch on the CT2002 Lar ge Display.)
Serial daisy chain
connectivty may also
be via CAT-5 cable and
RJ-45 conectors.
Use a standard 568B
ethernet patch cable
(all wires conecting
straight thru pin to pin)
or for custom made
cables observe pinouts
to right.
SERIAL INPUT
TERMINATION
RJ-45 OUT
RJ-45 IN
GND
+15V DC IN
RJ-45 SHIELD TO GND
1 2 3 4 5
6 7 8 9 10
1112131415
1617181920
Ancillary I/O
16- Ground
17- Down Time Closure a t “0”
18- Top-of-Hour Input
19- Ground
20- +15V DC
Remote Control
6- Ground
7- Start
8- Stop
9- Reset
10- Mode
Clock Triggers
11- Ground
12- Time Closure #1
13- Time Closure #2
14- Time Closure #3
15- Time Closure #4
Serial Synchronizing Data
1- Serial In +
2- Serial In -
3- Ground
4- Serial Out -
5- Serial Out +
REMOTE CONTROL BARRIER STRIP PIN-OUTS
To additional RJ-45
clock serial inputs.
SERIAL INPUT
RJ-45 PIN OUTS
1- n/c
2- n/c
3- Serial In +
4- Ground
5- Top-of-Hour Reset Input
6- Serial In -
(Note: Make serial connectivity EITHER
via twisted or CAT-5 (not both)
DB9 (FEMALE) PINOUTS
Pin 1- Serial Data Out +
Pin 2- Serial Data In +
Pin 3- Serial Data In -
Pin 4- Serial Data Out -
Pin 5- GND
Pin 6- TOH Reset
Pin 7- GND
Pin 8- N/C
Pin 9 N/C
Make serial connections to any
one of the DB9 connector or
either RJ-45 connector.
SERIAL OUTPUT /LOOP THRU
RJ-45 PIN OUTS
1- Serial Out +
2- Serial Out -
3- Serial In +
4- Ground
5- Top-of-Hour Reset Input
6- Serial In -
RS-232 to
RS-425
long cable
run converter
(optional)
PC Clock Input Sync
RS-485
to
RS-232
converter
RS-232
to
RS-485
converter
9
4
8
7
6
3
2
1
5
Note: Software/hardware
kit available (Radio Systems
part # CT-SYNC) to update
Windows PC clocks via USB
from the CT-2002 serial data
stream OR convert the Windows
time base to RS time code to
drive and synchronize the
CT-2002 system.
Logan Township, New Jersey USA
1-856-467-8000 • www .radiosystems.com
DOWN TIME CLOSURE AT “0”
+9V DC IN
GND
GND
START SW
STOP SW
RESET SW
MODE SW
GND
SERIAL IN -
SERIAL IN +
GND
TOP OF HOUR RESET INPUT
TIME CLOSURE 4
TIME CLOSURE 3
TIME CLOSURE 2
TIME CLOSURE 1
GND
SERIAL OUT - (future use)
SERIAL OUT + (future use)
J4
J6
FOR MASTER TIME SYNC VIA TOP-of-HOUR RESET
wire timer displays Top-of-Hour in for accurate time readout.
Note: T.O.H. input must be used to offset timer by one or more
seconds. Use IR remote control progam option 10 consult
manual page 11 for more information.
SERIAL INPUT
TERMINATION
RJ-45 OUT
RJ-45 IN
GND
+15V DC IN
RJ-45 SHIELD TO GND
1 2 3 4 5
6 7 8 9 10
1112131415
1617181920
GND
SERIAL OUT -
SERIAL OUT +
GND
START SWITCH
STOP SWITCH
RESET SWITCH
MODE SWITCH
GND
TIME CLOSURE 1
TIME CLOSURE 2
TIME CLOSURE 3
TIME CLOSURE 4
GND
DOWN TIME CLOSURE AT “0”
TOH RESET INPUT
RJ-45 OUT
RJ-45 IN
9V DC IN
MODEL CT-2002 DESKTOP Part No. 14409
SERIAL IN +
SERIAL IN -
RJ-45 SHIELD TO GND
Logan Township, New Jersey USA
1-856-467-8000 • www.radiosystems.com
CT-2002 4” & 2” or Desktop (Desktop Shown)
GND
SERIAL OUT -
SERIAL OUT +
GND
START SWITCH
STOP SWITCH
RESET SWITCH
MODE SWITCH
GND
TIME CLOSURE 1
TIME CLOSURE 2
TIME CLOSURE 3
TIME CLOSURE 4
GND
DOWN TIME CLOSURE AT “0”
TOH RESET INPUT
RJ-45 OUT
RJ-45 IN
9V DC IN
MODEL CT-2002 DESKTOP Part No. 14409
SERIAL IN +
SERIAL IN -
RJ-45 SHIELD TO GND
Logan Township, New Jersey USA
1-856-467-8000 • www.radiosystems.com
CT-2002 4” & 2” or Desktop (Desktop Shown)
Ancillary I/O
16- Ground
17- Down Time Closure at “0”
18- Top-of-Hour Input
19- Ground
20- +15V DC
Remote Control
6- Ground
7- Start
8- Stop
9- Reset
10- Mode
Clock Triggers
11- Ground
12- Time Closure #1
13- Time Closure #2
14- Time Closure #3
15- Time Closure #4
Serial Synchronizing Data
1- Serial In +
2- Serial In -
3- Ground
4- Serial Out -
5- Serial Out +
REMOTE CONTROL BARRIER STRIP PIN-OUTS
CT-2002 Large
FOR MASTER TIME SYNC VIA RADIO SYSTEMS or SMPTE SERIAL DATA
wire timer displays serial in with Radio Systems or SMPTE Time-of-Day
serial input for accurate time readout. Accurate time will be read by all
serially connected displays. Time may be offset by one or more hours
- use IR remote control progam option 4 consult manual page 10 for
more information.
Use a straight thru RJ-45 patch cable (from either RJ-45 connector) if
this clock is being fed with remote master time sync and if downstream
displays are not required to display remote timer information.
Repeat up to 35 displays.
Note: final display serial line must be terminated with a
150Ω resisitor (use terminator DIP switch on large clock.)
Use a crossover RJ-45 patch cable to slave Time-of-Day
and/or timer displays to downstream units.
Via the IR remote control enter the program mode and select option 3 for serial
time-of-day format. Select “rs1” for time-of-day only re-display from the master
clock. Select “rs2” for time-of-day and timer re-display from the master clock.
You must use a crossover RJ-45 patch cable if this display is the
master (first clock) in the serial chain or, if you want downstream
clockcs to display remote timer as well as Time-of-Day
PC Clock Input Sync
Note: Software/hardware
kit available (Radio Systems
part # CT-SYNC) to update
Windows PC clocks via USB
from the CT-2002
serial data stream
Radio Systems, Inc.
CT2002 Manual
Page 20
Serial Clock/Timer Connections between CT2002 stand-alone Models
Master/Slave Interconnection via RJ-45 Patch Cable Connections
Straight thru (Time-of-Day only)
RJ-45 Display Cable.
Crossover (Time-of-Day and Timer)
RJ-45 Display Cable.
RJ-45 Patch Cord Wiring
Radio Systems, Inc.
CT2002 Manual
Page 21
Serial Clock/Timer Connections between CT2002 stand-alone Models
Master/Slave Interconnection via Twisted Pair Connections
FOR MASTER TIME SYNC VIA TOP-of-HOUR RESET
wire timer displays Top-of-Hour in for accurate time readout.
Note: T.O.H. input must be used to offset timer by one or more
seconds. Use IR remote control progam option 10 consult
manual page 11 for more information.
FOR MASTER TIME SYNC VIA RADIO SYSTEMS or SMPTE SERIAL DATA
wire timer displays serial in with Radio Systems or SMPTE Time-of-Day
serial input for accurate time readout. Accurate time will be read by all
serially connected displays. Time may be offset by one or more hours
- use IR remote control progam option 4 consult manual page 10 for
more information.
CT-2002 4” & 2”, Desktop or Thin (Thin Shown)
GND
SERIAL OUT -
SERIAL OUT +
GND
START SWITCH
STOP SWITCH
RESET SWITCH
MODE SWITCH
GND
TIME CLOSURE 1
TIME CLOSURE 2
TIME CLOSURE 3
TIME CLOSURE 4
GND
DOWN TIME CLOSURE AT “0”
TOH RESET INPUT
RJ-45 OUT
RJ-45 IN
9V DC IN
MODEL CT-2002 DESKTOP Part No. 14409
SERIAL IN +
SERIAL IN -
RJ-45 SHIELD TO GND
Logan Township, New Jersey USA
1-856-467-8000 • www.radiosystems.com
CT-2002 Desktop
GND
SERIAL OUT -
SERIAL OUT +
GND
START SWITCH
STOP SWITCH
RESET SWITCH
MODE SWITCH
GND
TIME CLOSURE 1
TIME CLOSURE 2
TIME CLOSURE 3
TIME CLOSURE 4
GND
DOWN TIME CLOSURE AT “0”
TOH RESET INPUT
RJ-45 OUT
RJ-45 IN
9V DC IN
MODEL CT-2002 DESKTOP Part No. 14409
SERIAL IN +
SERIAL IN -
RJ-45 SHIELD TO GND
Logan Township, New Jersey USA
1-856-467-8000 • www.radiosystems.com
CT-2002 4” & 2”,
Desktop or Thin (Desktop Shown)
Connect serial inputs
in parallel to slave
downstreamTime-of-
Day displays only.
Connect serial output to
downstream clocks’ serial input
to slave Time-of-Day and timer
readouts, or if this is the master
(first) clock in the serial chain.
Connect serial inputs
in parallel to slave
downstreamTime-of-
Day displays only.
Repeat up to 35 displays.
Note: final display serial line
must be terminated with a
150Ω resisitor (use terminator
DIP switch on large clock.)
Connect serial output to downstream
clocks’ serial input to slave Time-of-Day
and timer readouts, or if this is the master
(first) clock in the serial chain.
PC Clock Input Sync
Note: Software/hardware
kit available (Radio Systems
part # CT-SYNC) to update
Windows PC clocks via USB
from the CT-2002
serial data stream
DOWN TIME CLOSURE AT “0”
+9V DC IN
GND
GND
START SW
STOP SW
RESET SW
MODE SW
GND
SERIAL IN -
SERIAL IN +
GND
TOP OF HOUR RESET INPUT
TIME CLOSURE 4
TIME CLOSURE 3
TIME CLOSURE 2
TIME CLOSURE 1
GND
SERIAL OUT - (future use)
SERIAL OUT + (future use)
J4
J6
Radio Systems, Inc.
CT2002 Manual
Page 22
Connection Diagrams
CT-2002 GPS Antenna Wiring Options
CT-2002 GPS Driver
1 2 3 4 5 6 7 8
12345678
DIP SWITCHES
(UP IS ON)
ANTENNA
15V DC IN
MODEL CT-2002 GPS Part No. 14411
Logan Township, New Jersey USA
1-856-467-8000 • www.radiosystems.com
CT-2002 GPS Driver
1 2 3 4 5 6 7 8
12345678
DIP SWITCHES
(UP IS ON)
ANTENNA
15V DC IN
MODEL CT-2002 GPS Part No. 14411
Logan Township, New Jersey USA
1-856-467-8000 • www.radiosystems.com
CT-2002 GPS Driver
1 2 3 4 5 6 7 8
12345678
DIP SWITCHES
(UP IS ON)
ANTENNA
15V DC IN
MODEL CT-2002 GPS Part No. 14411
Logan Township, New Jersey USA
1-856-467-8000 • www.radiosystems.com
Satellite Receiver
Antenna
Note: The cable used must be shielded with the ground connected to pin 1 on both ends.
For cable lengths over 150', install Radio Systems RS-485 balancing amplifiers.
Pin 1 = Ground & Shield
Pin 2 = +15V
Pin 4 = 1 P.P.S.
Pin 6 = Data
87654321
RJ-45 Patch Cable
250' factory
shielded cable or user
provided shielded 4 conductor
cable up to 500'
Note- Shielded Cable may be shortened,
but not spliced longer.
From Antenna
To Cable
To Clock
From Cable
RS-485 to RS-232
RS232 to RS-485
RJ-11
RJ-11
I. -with user provided cable
II. -with factory 150'
extension cable
III. -with RS-485 converter box
(for cable runs over 150'
and up to 1000')
Satellite Receiver
Antenna
Satellite Receiver
Antenna
up to 150' Shielded Cable
Note: (on white-bodied antennas)
yellow, black and ground wires shorted
at connector
RJ-45 Patch Cable
Radio Systems, Inc.
CT-2002 Manual
Page 23
Connection Diagrams
CT-2002 GPS Dip Switch Settings
India (New Delhi) Time
5 1/2 hours ahead of GMT
(No Daylight Savings/12 hour/
Analog Clocks connected)
Note:
Special software prom p/n 16119 required.
Prom adds 1/2 hour to all time offset settings.
Radio Systems, Inc.
CT-2002 Manual
Page 24
Warranty
Radio Systems, Inc., warrants this equipment to be free from defects in materials
and workmanship for a period of one (1) year.
This warranty extends to first users of the product and future owners who pur-
chase the product within the warranty period.
The terms of this warranty are null and void if this product is stored or operated in
an environment not conducive to electronic equipment, or shows signs of misuse
or modifications which affect the proper functioning of the product. This warranty
does not apply to damage caused by fire, smoke, flood, lightning, or acts of nature
and physical abuse.
Radio Systems, Inc., and its associated companies, authorized distributors, and
personnel are not liable for loss of revenues or other damages, or effects to the
broadcast signal quality or coverage which may result from the from the improper
functioning of this product.
Repair Policy
Technical assistance is available at any time, at no charge, by phone or corre-
spondence.
During the warranty period, there will be no charge for parts or service made to
units which show no sign of misuse by customer or lightning caused damage. The
customer is responsible for the cost of shipping their unit back to Radio Systems
for repair.
During the warranty period, shipment of small parts and assemblies may also be
made at a charge to the user. Emergency shipments of replacement parts and cir-
cuits will be made at the user’s request for an extra shipping and service charge.
Chargeable services will be made COD or on Net-30 day terms to users with
established accounts.
During the warranty period, full credit or return of COD charges (less any service
and expedited shipping charges) will be made to users who return the defective
parts or circuits within 30 days, if the damage is covered under the terms of the
warranty.
Return Instructions
Contact Radio Systems for a return authorization number.
Pack all items carefully and ship prepaid, via UPS insured, to:
Radio Systems, Inc.
Attn: R.A. # __________
601 Heron Drive
Logan Township, New Jersey 08085-1741
Enclose a note which includes your name, company, phone number, the serial
number, return address (no box numbers), and a complete description of the .
problem.
(856) 467-8000 • Fax (856) 467-3044.
601 Heron Drive • Logan Township, New Jersey 08085 • www.radiosystems.com
For Assy.
Part # 14691
rev. 9/09