Goodman ACVC9 Copyright ©2009-2010 Goodman Manufacturing Company, L.P.
RT6612021 Rev. 4
December 2010
This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does
not assume any responsibility for property damage or personal injury due to improper service
procedures performed by an unqualified person.
ACVC9/AMVC95
GCVC9/GMVC95
90%-95% Gas Furnace Units
•
Refer to Service Manual RS6200004 for installation, operation, and t
The model and manufacturing number are used for positive identification of component parts used in manufacturing.
Please use these numbers when requesting service or parts information.
WARNING
WARNING
HIGH VOLTAGE!
Disconnect ALL power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal
injury or death.
Installation and repair of this unit
should be p
The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please
use these numbers when requesting service or parts information.
AMVC950453BXAA
AMVC950704CXAA
AMVC950905CXAA
AMVC950905DXAA
AMVC951155DXAA
ACVC90704CXAA
ACVC90905DXAA
AMVC950453BXAB
AMVC950704CXAB
AMVC950905DXAB
AMVC951155DXAB
ACVC90704CXAB
ACVC90905DXAB
ACVC950714CXAA
ACVC950915DXAA
The United States Environmen
installation (1 or 2 pipes). The optional Combustion Air
Pipe is dependent on installation/code requirements and
must be 2” or 3” diameter PVC.
2. Line voltage wiring can enter through the right or left side
of the furnace. Low voltage wiring can enter through the
right or left side of furnace.
3. Conversion kits for propane gas and high altitude natural
and propane gas operation are available. See High Alti-
tude Derate chart for deta
Goodman ACVC9 quired due to the natural reduction in the density of both the
gas fuel and combustion air as altitude increases. The kit
will provide the proper design certified input rate within the
specified altitude range.
High altitude kits are purchased according to the installa-
tion altitude and usage of either natural or propane gas. Refer
to the chart above for a tabular listing of appropriate altitude
ranges and corresponding manufacturer’s h
Two-Stage Gas Valve
2
Gas Line Entrance (Alternate)
3
Pressure Switch(es)
4
Gas Manifold
5
Combustion Air Intake Connection
6
Hot Surface Igniter
7
Rollout Limit
8
Burners
9
Flame Sensor
10 Flue Pipe Connection
11 Flue Pipe
12 Primary Limit
13 Gas Line Entrance
14 Flue Pipe Connection (Alternate)
15 Rubber Elbow
16 Two-Speed Induced Draft Blower
17 Electrical Connection Inlets (Alternat
Goodman ACVC9 NOTE: Airflow area will be reduced by approximately 18% if duct flanges are not unfolded. This could cause performance issues and noise issues.
AIR
DISCHARGE
AIR
DISCHARGE
LOW VOLTAGE
ELECTRICAL HOLE
HIGH VOLTAGE
ELECTRICAL HOLE
SIDE CUT-OUT
LEFT SIDE
VIEW
SIDE CUT-OUT
HIGH VOLTAGE
ELECTRICAL HOLE
LOW VOLTAGE
ELECTRICAL HOLE
RIGHT SIDE
DRAIN LINE
HOLES
STANDARD GAS
SUPPLY HOLE
DRAIN
TRAP
19 3/4
AIR INTAKE
PIPE
2" PVC