IDS X64 Quick Programming Guide 700-398-03A Issued August 2010

3 LOCATION 0 Defaulting the Panel or Master User Code [#] [INSTALLER CODE] [*] [0] [*] [VALUE] [*] Value Action 0 Will reset all locations to the factory default values. (Master User Code 1234) and all keypad IDs will be defaulted. 1 Will default the master user code to 1234 - or 123456 if 6 digits are being used. Master user code properties will also be defaulted. 2 Defaults ALL user codes and their properties. 3 Defaults ALL keypads 4 Remove Missing Devices Any missing devices (keypads, for example), will have its address freed up, making its address available for a new device when it is enrolled. This MUST be performed when replacing a faulty device. (You must wait for 10 seconds.)

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010

4 LOCATIONS 1 - 8 Individual Zone Type Setup (Zones 1 – 64) [#] [INSTALLER CODE] [*] [LOCATION] [*] [ZONE NUMBER] [*] [ZONE TYPE] [*] Location = 1 – 8 Zone number = 1 – 64 Value Zone Type 00 DISABLED A zone violation of a Disabled zone is ignored by the control panel and will not be indicated on the keypad. 01 PRIMARY ENTRY / EXIT ZONE Violations of an Entry/Exit zone are ignored during the exit delay period of the arming procedure. Violating an Entry/Exit zone when armed will initiate the entry delay. If a valid User Code is not entered before the entry delay period expires, an alarm condition will be registered. Failure to exit through an Entry/Exit zone after arming will cause the panel to Stay Arm. This zone may also function as an Entry/Exit zone that is COMMON to two partitions. In such a case, should a user violate this zone and then disarm his partition, the OTHER partition will re-arm after the entry delay. 02 FOLLOWER ZONE A violation of a Follower zone is ignored during the Entry/Exit delay period (this allows the user to enter/exit via the Follower zone). A Follower zone will behave as an Instant zone if the panel is armed and an Entry/Exit zone is not violated prior to violation of the Follower zone. 03 PANIC / PRIORITY ZONE Regardless of whether the panel is armed or not, a violation of a Priority zone will cause the control panel to register a panic condition. This zone type CANNOT be bypassed. 04 INSTANT ZONE When the panel is armed the violation of an Instant zone will cause the control panel to register an alarm condition. 05 ARM / DISARM ZONE The violation of an Arm/Disarm zone will cause the panel to toggle between (away) armed and disarmed. It is typical to connect a momentary key-switch, or non-latching remote control unit to this zone. 08 SECONDARY ENTRY / EXIT ZONE The Secondary Entry delay will be activated if this zone is violated when the panel is armed. 10 FIRE ZONE Violation of a Fire Zone will cause the siren to sound regardless of whether the panel is armed or not. The siren will sound intermittently (one second on, one second off). For correct operation, a programmable output programmed as a fire detector power output must be used to control power to the fire detector. 11 TAMPER ZONE Violation of this zone will be reported to the base station regardless of whether the panel is armed or disarmed. If the panel is armed, the siren will be activated. 12 24 HOUR ALARM ZONE This works the same as a Panic zone – with the exception that it is able to be bypassed. 13 WARNING ZONE When the panel is armed, violation of a Warning zone will cause the siren to beep. The violation is logged in the event log but it is not reported to the base station. Warning zones may be included and will be counted when used as part of the cross-zone 14 PUSH TO ARM ZONE Violation of a Push to Arm zone during the exit delay will immediately arm the panel. 15 OUTDOOR INSTANT ZONE When the panel is armed the violation of an Outdoor Instant zone will cause the panel to register an alarm condition.

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010

5 LOCATION 10 Zone Shutdown Count (default = 5) [#] [INSTALLER CODE] [*] [1] [0] [*] [ZONE SHUTDOWN COUNT] [*] Zone shutdown count = 1 – 15 LOCATION 11 Programmable Zone Loop Response Time (default = 2) [#] [INSTALLER CODE] [*] [1] [1] [*] [ZONE LOOP RESPONSE TIME] [*] Zone loop response time = 1 – 255 LOCATION 12 Cross-zone Delay Time (default = 0030) [#] [INSTALLER CODE] [*] [1] [2] [*] [MMSS] [*] MMSS = 00m00s – 59m59s LOCATION 13 Cross-zone Count (default = 3) [#] [INSTALLER CODE] [*] [1] [3] [*] [CROSS-ZONE COUNT] [*] Cross zone count = 1 – 15, with 0 to disable

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010

6 LOCATION 14 Global Options [#] [INSTALLER CODE] [*] [1] [4] [*] [BITMAP] [*] LED On / Off Action 1 ON A user assigned to any partition may cancel the siren OFF Only a user assigned to the partition that triggered the siren may cancel the siren 2 ON Enable keypad trouble beep OFF Disable keypad trouble beep 3 ON Enable telephone line monitoring OFF Disable telephone line monitoring 4 ON Enable keypad beep on successful reporting to the base station OFF Disable keypad beep on successful reporting to the base station 5 ON Enable keypad Fire, Medical and Panic keys OFF Disable keypad Fire, Medical and Panic keys 6 ON Enable the display of bypassed and stay zones when armed OFF Disable the display of bypassed and stay zones when armed 7 ON Enable the siren delay OFF Disable the siren delay 8 ON Enable box tamper monitoring OFF Disable box tamper monitoring 9 ON Enable siren monitoring OFF Disable siren monitoring 10 ON Enable bus-wired peripheral tamper monitoring* OFF Disable bus-wired peripheral tamper monitoring* 11 ON Enable onboard dedicated panic – silent OFF Disable onboard dedicated panic– audible 12 ON Enable low battery monitoring** OFF Disable low battery monitoring** 13 ON Enable low battery cut-out** OFF Disable low battery cut-out** Default values are shaded * Option 9 in location 16 must be enabled for this to work. ** Option 12 needs to be enabled in order for option 13 to work. LOCATION 15 AC Fail / Restore Reporting Delay (default = 0004) [#] [INSTALLER CODE] [*] [1] [5] [*] [HHMM] [*] HHMM = 00h01m – 18h00m all-guides com

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010

7 LOCATION 16 Trouble Display Enable [#] [INSTALLER CODE] [*] [1] [6] [*] [BITMAP] [*] LED On / Off Action 1 ON Enable AC fail trouble display OFF Disable AC fail trouble display 2 ON Enable reporting communications fail trouble display OFF Disable reporting communications fail trouble display 3 ON Enable telephone line monitoring trouble display OFF Disable telephone monitoring line trouble display 4 ON Enable siren monitoring trouble display OFF Disable siren monitoring trouble display 5 ON Enable low battery monitoring trouble display OFF Disable low battery monitoring trouble display 6 ON Enable Aux. 12V monitoring trouble display OFF Disable Aux. 12V monitoring trouble display 7 ON Enable engineer's reset trouble display OFF Disable engineer’s reset trouble display 8 ON Enable box tamper trouble display OFF Disable box tamper trouble display 9 ON Enable bus-wired peripheral tamper trouble display OFF Disable bus-wired peripheral tamper trouble display 10 ON Enable bus-wired peripheral fail trouble display OFF Disable bus-wired peripheral fail trouble display 11 ON Enable bus-wired peripheral low power/ battery trouble display OFF Disable bus-wired peripheral low power/ battery trouble display 12 ON Enable EEPROM trouble display OFF Disable EEPROM trouble display Default values are shaded LOCATION 17 Siren Time Out Period (default = 0200) [#] [INSTALLER CODE] [*] [1] [7] [*] [MMSS] [*] MMSS = 00m01s – 59m59s LOCATION 18 Siren Delay (default = 0200) [#] [INSTALLER CODE] [*] [1] [8] [*] [MMSS] [*] MMSS = 00m01s – 59m59s LOCATION 20 Keypad Lockout Count (default = 4) [#] [INSTALLER CODE] [*] [2] [0] [*] [KEYPAD LOCKOUT COUNT] [*] Lockout count = 2 – 16

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010

8 LOCATION 21 Keypad Lockout Time (default = 0030) [#] [INSTALLER CODE] [*] [2] [1] [*] [MMSS] [*] MMSS = 00m01s – 59m59s LOCATION 22 Keypad Sleep Delay (default = 0500) [#] [INSTALLER CODE] [*] [2] [2] [*] [MMSS] [*] MMSS = 00m01s – 59m59s LOCATION 23 User, Installer & Maintenance Code - Number of Digits (default = 4) [#] [INSTALLER CODE] [*] [2] [3] [*] [NUMBER OF DIGITS] [*] Number of digits = 4 or 6 LOCATION 24 Number of Account Code Digits (default = 4) [#] [INSTALLER CODE] [*] [2] [4] [*] [NUMBER OF DIGITS] [*] Number of digits = 4 or 6 LOCATION 25 Month to Start Daylight Saving (default = 1) [#] [INSTALLER CODE] [*] [2] [5] [*] [MONTH] [*] Month = 1 – 12, with 0 to disable LOCATION 26 Day of Week to Start Daylight Saving (default = 1) [#] [INSTALLER CODE] [*] [2] [6] [*] [DAY] [*] Day = 1 – 7 LOCATION 27 Week of Month to Start Daylight Saving (default = 1) [#] [INSTALLER CODE] [*] [2] [7] [*] [WEEK] [*] Week = 1 – 5 LOCATION 28 Month to End Daylight Saving (default = 1) [#] [INSTALLER CODE] [*] [2] [8] [*] [MONTH] [*] Month = 1 – 12, with 0 to disable LOCATION 29 Day of Week to End Daylight Saving (default = 1) [#] [INSTALLER CODE] [*] [2] [9] [*] [DAY] [*] Day = 1 – 7

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010

9 LOCATION 30 Week of Month to End Daylight Saving (default = 1) [#] [INSTALLER CODE] [*] [3] [0] [*] [WEEK] [*] Week = 1 – 5 LOCATION 31 Daylight Saving Time Offset (default = 60) [#] [INSTALLER CODE] [*] [3] [1] [*] [DAYLIGHT SAVING TIME OFFSET] [*] Daylight saving time = 0 – 250 LOCATION 32 Auto Test Report Interval (default = 1) [#] [INSTALLER CODE] [*] [3] [2] [*] [AUTO TEST REPORT INTERVAL] [*] Auto test interval = 0 – 15 LOCATION 33 Auto Test Time (default = 0010) [#] [INSTALLER CODE] [*] [3] [3] [*] [HHMM] [*] HHMM = 00h00m – 23h59m LOCATION 34 Download Code Default Disable (default = 0) [#] [INSTALLER CODE] [*] [3] [4] [*] [DOWNLOAD CODE DEFAULT DISABLE] [*] Download code default disable = 0 or 10 LOCATION 35 Hardware Default Switch Disable (default = 0) [#] [INSTALLER CODE] [*] [3] [5] [*] [HARDWARE DEFAULT SWITCH DISABLE] [*] Reset switch disable = 0 or 10 LOCATION 41 Telephone Number 1 Communications Format (default = 5) [#] [INSTALLER CODE] [*] [4] [1] [*] [TELEPHONE NO. 1 COMMUNICATIONS FORMAT] [*] Value Format Name Description 0 Ademco Express Dual Tone HS, DTMF 1 FBI 4 x 2 ( With Parity) 1.8kHz TX, 2.3kHz HS, 40PPS 2 FBI 4 x 2 (No Parity) 1.8kHz TX, 2.3kHz HS, 20PPS 3 Silent Knight 4 x 2 Fast 1.9kHz TX, 1.4kHz, 20PPS 4 Silent Knight 4 x 2 Slow 1.9kHz TX, 1.4kHz, 20PPS 5 Contact ID Dual Tone HS, DTMF 6 Reserved 7 SIA Reporting 1170Hz TX, Blind 20PPS 8 Reserved Telephone No. 1 Communications Format = 0 – 8

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010

10 LOCATION 42 Telephone Number 2 Communications Format (default = 5) [#] [INSTALLER CODE] [*] [4] [2] [*] [TELEPHONE NO. 2 COMMUNICATIONS FORMAT] [*] Telephone No.2 Communications Format = 0 – 8 LOCATION 43 Telephone Number 3 Communications Format (default = 5) [#] [INSTALLER CODE] [*] [4] [3] [*] [TELEPHONE NO. 3 COMMUNICATIONS FORMAT] [*] Telephone No. 3 Communications Format = 0 – 8 LOCATION 44 Telephone Number 4 Communications Format (default = 5) [#] [INSTALLER CODE] [*] [4] [4] [*] [TELEPHONE NO. 4 COMMUNICATIONS FORMAT] [*] Telephone No. 4 Communications Format = 0 – 8 LOCATION 45 Communication Delay (default = 0020) [#] [INSTALLER CODE] [*] [4] [5] [*] [MMSS] [*] MMSS = 00m01s – 59m59s LOCATION 46 Reporting Communications Options [#] [INSTALLER CODE] [*] [4] [6] [*] [BITMAP] [*] LED On / Off Action 1 ON Tone Dialling Enabled OFF Pulse Dialling Enabled 2 ON Join the telephone numbers together OFF Keep two separate telephone numbers 3 ON Enable Dual Reporting OFF Disable Dual Reporting Default values are shaded LOCATION 47 Number of Dial Attempts (default = 6) [#] [INSTALLER CODE] [*] [4] [7] [*] [NUMBER OF DIAL ATTEMPTS] [*] Number of dial attempts = 1 – 9, with 0 to disable

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010

11 LOCATION 48 Download Options [#] [INSTALLER CODE] [*] [4] [8] [*] [BITMAP] [*] LED On / Off Action 1 ON Enable Fax Defeat OFF Disable Fax Defeat 2 ON Enable Forced Answer OFF Disable Forced Answer 3 ON Enable Auto Pickup OFF Disable Auto Pickup 4 ON Enable Call-back OFF Disable Call-back Default values are shaded LOCATION 49 Number of Rings to Answer (default = 15) [#] [INSTALLER CODE] [*] [4] [9] [*] [NUMBER OF RINGS TO ANSWER] [*] Number of rings to answer = 1 – 15 LOCATION 50 Call-back Telephone Number [#] [INSTALLER CODE] [*] [5] [0] [*] [CALL-BACK NUMBER] [*] Call-back number = a maximum of 24-digits LOCATION 51 Telephone Number 1 [#] [INSTALLER CODE] [*] [5] [1] [*] [TELEPHONE NUMBER 1] [*] Phone number 1 = a maximum of 24-digits LOCATION 52 Telephone Number 2 [#] [INSTALLER CODE] [*] [5] [2] [*] [TELEPHONE NUMBER 2] [*] Phone number 2 = a maximum of 24-digits LOCATION 53 Telephone Number 3 [#] [INSTALLER CODE] [*] [5] [3] [*] [TELEPHONE NUMBER 3] [*] Phone number 3 = a maximum of 24-digits LOCATION 54 Telephone Number 4 [#] [INSTALLER CODE] [*] [5] [4] [*] [TELEPHONE NUMBER 1] [*] Phone number 4 = a maximum of 24-digits all-guides com

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010

12 LOCATIONS 61-68 Primary Account Codes (Partitions 1- 8) [#] [INSTALLER CODE] [*] [LOCATION] [*] [PRIMARY ACCOUNT CODE] [*] Location = 61 – 68 LOCATIONS 71-78 Secondary Account Codes (Partitions 1- 8) [#] [INSTALLER CODE] [*] [LOCATION] [*] [SECONDARY ACCOUNT CODE] [*] Location = 71 – 78 LOCATIONS 101-164 Zone Type Properties (Zones 1 – 64) [#] [INSTALLER CODE] [*] [LOCATION] [*] [BITMAP] [*] Location = 101 – 164 LED ON / OFF Zone Properties LED ON / OFF Zone Properties 1 ON Tamper by Zone Enabled 9 ON Stay Profile 1 OFF Tamper by Zone Disabled OFF 2 ON Cross-zone Enabled 10 ON Stay Profile 2 OFF Cross-zone Disabled OFF 3 ON Shutdown Zone Enabled 11 ON Stay Profile 3 OFF Shutdown Zone Disabled OFF 4 ON Silent Zone Enabled 12 ON Stay Profile 4 OFF Silent Zone Disabled OFF 5 ON Chime Zone Enabled 13 ON Buzz Profile 1 OFF Chime Zone Disabled OFF 6 14 ON Buzz Profile 2 OFF 7 15 ON Buzz Profile 3 OFF 8 16 ON Buzz Profile 4 OFF Default values are shaded LOCATION 171 No Movement Auto Arm Time Out (default = 00) [#] [INSTALLER CODE] [*] [1] [7] [1] [*] [PARTITION NUMBER] [*] [AUTO ARM TIME OUT] [*] Partition number = 1 – 8 Auto arm time out = 01 – 23, with 00 to disable LOCATION 172 No Movement Auto Arm Start (default = 0000) [#] [INSTALLER CODE] [*] [1] [7] [2] [*] [PARTITION NUMBER] [*] [HHMM] [*] Partition number = 1 – 8 HHMM = 00h00m – 23h59m,

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010

13 LOCATION 173 No Movement Auto Arm End (default = 2400) [#] [INSTALLER CODE] [*] [1] [7] [3] [*] [PARTITION NUMBER] [*] [HHMM] [*] Partition number = 1 – 8 HHMM = 00h00m – 23h59m LOCATION 174 No Movement Medical Alarm (default = 00) [#] [INSTALLER CODE] [*] [1] [7] [4] [*] [PARTITION NUMBER] [*] [ALARM TIME OUT] [*] Partition number = 1 – 8 Alarm arm time out = 01 – 23, with 00 to disable LOCATION 175 No Movement Medical Alarm Start (default = 0100) [#] [INSTALLER CODE] [*] [1] [7] [5] [*] [PARTITION NUMBER] [*] [HHMM] [*] Partition number = 1 – 8 HHMM = 00h00m – 23h59m LOCATION 176 No Movement Alarm End (default = 0100) [#] [INSTALLER CODE] [*] [1] [7] [6] [*] [PARTITION NUMBER] [*] [HHMM] [*] Partition number = 1 – 8 HHMM = 00h00m – 23h59m LOCATION 180 Auto Arm Time (default = 2400) [#] [INSTALLER CODE] [*] [1] [8] [0] [*] [PARTITION NUMBER] [*] [HHMM] [*] Partition number = 1 – 8 HHMM = 00h00m – 23h59m, with 24h00m to disable LOCATIONS 181 - 188 Auto Arm/Disarm Days (default = all OFF) [#] [INSTALLER CODE] [*] [LOCATION] [*] [BITMAP] [*] Location = 181 - 188 LED ARM Days of the Week LED DISARM Days of the Week 1 Monday 9 Monday 2 Tuesday 10 Tuesday 3 Wednesday 11 Wednesday 4 Thursday 12 Thursday 5 Friday 13 Friday 6 Saturday 14 Saturday 7 Sunday 15 Sunday All OFF (Arm Day Disabled) All OFF (Disarm Day Disabled)

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010

14 LOCATION 189 Auto Disarm Time (default = 2400) [#] [INSTALLER CODE] [*] [1] [8] [9] [*] [PARTITION NUMBER] [*] [HHMM] [*] Partition number = 1 – 8 HHMM = 00h00m – 23h59m, with 24h00m to disable LOCATION 190 Auto Arm Delay (default = 0200 i.e. 2 minutes) [#] [INSTALLER CODE] [*] [1] [9] [0] [*] [PARTITION NUMBER] [*] [MMSS] [*] Partition number = 1 – 8 MMSS = 00m01s – 59m59s LOCATION 197 Installers Code (default = 9999) [#] [INSTALLER CODE] [*] [1] [9] [7] [*] [NEW INSTALLER CODE] [*] LOCATION 198 Download Code (default = 9999) [#] [INSTALLER CODE] [*] [1] [9] [8] [*] [NEW DOWNLOAD CODE] [*] LOCATION 199 Maintenance Code (default = 8888) [#] [INSTALLER CODE] [*] [1] [9] [9] [*] [NEW MAINTENACE CODE] [*] LOCATIONS 201 - 208 Partition Zone Allocation [#] [INSTALLER CODE] [*] [LOCATION] [*] [BITMAP] [*] Location = 201 – 208 Page 1 2 3 4 LED Indicator READY ARMED AWAY POWER Zones 1 9 2 10 3 11 4 12 5 13 6 14 7 15 8 16 17 25 18 26 19 27 20 28 21 29 22 30 23 31 24 32 33 41 34 42 35 43 36 44 37 45 38 46 39 47 40 48 49 57 50 58 51 59 52 60 53 61 54 62 55 63 56 64 LOCATIONS 211 - 218 Partition Arm Options (Partitions 1 – 8) [#] [INSTALLER CODE] [*] [LOCATION] [*] [BITMAP] [*] Location = 211 – 218

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010

15 LED On / Off Action 1 ON Enable Instant Arm OFF Disable Instant Arm 2 ON Enable Instant Key-switch Arm OFF Disable Instant Key-switch Arm 3 ON Enable Quick Arm Key OFF Disable Quick Arm Key 4 ON Enable Quick Stay Arm Key OFF Disable Quick Stay Arm Key 5 ON Enable Auto Stay Arm if No Exit Zone is Triggered* OFF Panel Away Arms Regardless of Zone Triggered* 6 ON Enable Auto Stay Arm if No Exit Zone is Triggered When Arming with a Key- switch* OFF Disable Auto Stay Arm if No Exit Zone is Triggered When Arming with a Key-switch * 7 ON Enable Forced Arm OFF Disable Forced Arm 8 ON Enable Zone Bypassing OFF Disable Zone Bypassing 9 ON Enable Arm with Zones in the Entry Route Violated OFF Disable Arm with Zones in the Entry Route Violated 10 ON Enable Siren Toot on Arm OFF Disable Siren Toot on Arm 11 ON Enable Siren Toot on Disarm OFF Disable Siren Toot on Disarm 12 ON Enable the Entry Beep OFF Disable the Entry Beep 13 ON Enable the Exit Beep OFF Disable the Exit Beep 14 ON Enable Engineer's Reset OFF Disable Engineer's Reset 15 ON Enable Auto Disarm OFF Disable Auto Disarm Default values are shaded * For option 5 or 6 to work, option 2 needs to be disabled. LOCATIONS 221 - 228 Extra Partition Options (Partitions 1 - 8) [#] [INSTALLER CODE] [*] [LOCATION] [*] [BITMAP] [*] Location = 221 – 228

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010

16 LED On/ Off Action 1 ON Enable Automatic Re-enabling of Shutdown Zones at the Time of the Dialler test OFF Disable Automatic Re-enabling of Shutdown Zones at the Time of the Dialler test 2 ON Enable Bypassing of Common Zones OFF Disable Bypassing of Common Zones 3 ON Enable Delay Before Communications OFF Disable Delay Before Communications 4 ON Enable Keypad Lockout OFF Disable Keypad Lockout 5 ON Enable Silent Keypad Panic OFF Disable Silent Keypad Panic Default values are shaded LOCATION 230 Exit Delay Period (default = 0030 i.e. 30 seconds) [#] [INSTALLER CODE] [*] [2] [3] [0] [*] [PARTITION NUMBER] [*] [MMSS] [*] Partition number = 1 – 8 MMSS = 00m00s – 59m59s LOCATION 231 Primary Entry Delay Period (default = 0030 i.e. 30 seconds) [#] [INSTALLER CODE] [*] [2] [3] [1] [*] [PARTITION NUMBER] [*] [MMSS] [*] Partition number = 1 – 8 MMSS = 00m00s – 59m59s LOCATION 232 Secondary Entry Delay Period (default = 0030 i.e. 30 seconds) [#] [INSTALLER CODE] [*] [2] [3] [2] [*] [PARTITION NUMBER] [*] [MMSS] [*] Partition number = 1 – 8 MMSS = 00m00s – 59m59s LOCATION 240 Keypad Partition (default = Partition 1) [#] [INSTALLER CODE] [*] [2] [4] [0] [*] [KEYPAD NUMBER] [*] [PARTITION NUMBER] [*] Keypad number = 1 – 8 Partition number = 1 – 8 LOCATION 241 Keypad Display Start Zone (default = Zone 1) [#] [INSTALLER CODE] [*] [2] [4] [1] [*] [KEYPAD NUMBER] [*] [START ZONE] [*] Keypad number = 1 – 8 Start zone = 01 – 64 all-guides com

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010

17 LOCATION 242 Keypad Zone Number (default = 0, i.e. Disabled) [#] [INSTALLER CODE] [*] [2] [4] [2] [*] [KEYPAD NUMBER] [*] [ZONE NUMBER] [*] Keypad number = 1 – 8 Start zone = 01 – 64 LOCATION 243 View Keypad ID [#] [INSTALLER CODE] [*] [2] [4] [3] [*] LOCATIONS 251 - 258 Keypad Options [#] [INSTALLER CODE] [*] [LOCATION] [*] [BITMAP] [*] Location = 251 – 258 LED On / Off Action 1 ON The keypad will timeout back to its default partition after it has been used to view another partition OFF The keypad will not timeout and will continue to show current partition information 2 ON Keypad sleep mode enabled OFF Keypad sleep mode disabled 3 ON Enable Global Keypad Status OFF Disable Global Keypad Status Default values are shaded LOCATION 300 Global Reporting Code 1 [#] [INSTALLER CODE] [*] [3] [0] [0] [*] [SUB-LOCATION] [*] [REPORTING CODE] [*] Sub-location = 1 – 8 Sub-location 1 is AC Fail Sub-location 2 is AC Restore Sub-location 3 is Low Battery Monitor Fail Sub-location 4 is Low Battery Monitor Restore Sub-location 5 is Auto Test Sub-location 6 is Download Sub-location 7 is Siren Monitor Fail Sub-location 8 is Aux 12V Monitor Fail Reporting code = 01 – FF, with 00 to disable LOCATION 301 Global Reporting Code 2 [#] [INSTALLER CODE] [*] [3] [0] [1] [*] [SUB-LOCATION] [*] [REPORTING CODE] [*] Sub-location = 1 – 8 Sub-location 1 is Reserved Sub-location 2 is Bus-wired Peripheral Tamper

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010

18 Sub-location 3 is Bus-wired Peripheral Fail Sub-location 4 is Box Tamper Sub-location 5 is Dedicated Panic Sub-location 6 is Reserved Sub-location 7 is Telephone Line Tamper Sub-location 8 is Telephone Line Restore Reporting code = 01 – FF, with 00 to disable LOCATION 303 Global Reporting Code 4 [#] [INSTALLER CODE] [*] [3] [0] [3] [*] [SUB-LOCATION] [*] [REPORTING CODE] [*] Sub-location = 1 – 8 Sub-location 1 is Wired Zone Expander Low Power Supply Monitoring Sub-location 2 is Wired Zone Expander Low Power Supply Restore Sub-location 3 is Reserved Sub-location 4 is Reserved Sub-location 5 is Reserved Sub-location 6 is Reserved Sub-location 7 is Reserved Sub-location 8 is Reserved Reporting code = 01 – FF, with 00 to disable LOCATIONS 304 - 307 Zone Alarm Reporting Code [#] [INSTALLER CODE] [*] [LOCATION] [*] [ZONE NUMBER] [*] [REPORTING CODE] [*] Location = 304 – 307 Zone Number = 01 – 64 Reporting code = 01 – FF, with 00 to disable LOCATIONS 308 - 311 Zone Alarm Restoral Reporting Code [#] [INSTALLER CODE] [*] [LOCATION] [*] [ZONE NUMBER] [*] [REPORTING CODE] [*] Location = 308 – 311 Zone Number = 01 – 64 Reporting code = 01 – FF, with 00 to disable LOCATIONS 312 - 315 Zone Tamper Reporting Code [#] [INSTALLER CODE] [*] [LOCATION] [*] [ZONE NUMBER] [*] [REPORTING CODE] [*] Location = 312 – 315 Zone Number = 01 – 64 Reporting code = 01 – FF, with 00 to disable LOCATIONS 316 - 319 Zone Tamper Restore Reporting Code [#] [INSTALLER CODE] [*] [LOCATION] [*] [ZONE NUMBER] [*] [REPORTING CODE] [*] Location = 316 – 319 Zone Number = 01 – 64

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010

19 Reporting code = 01 – FF, with 00 to disable LOCATIONS 320 - 323 Zone Bypass Reporting Code [#] [INSTALLER CODE] [*] [LOCATION] [*] [ZONE NUMBER] [*] [REPORTING CODE] [*] Location = 320 – 323 Zone Number = 01 – 64 Reporting code = 01 – FF, with 00 to disable LOCATIONS 324 - 327 Zone Force Arm Reporting Code [#] [INSTALLER CODE] [*] [LOCATION] [*] [ZONE NUMBER] [*] [REPORTING CODE] [*] Location = 324 – 327 Zone Number = 01 – 64 Reporting code = 01 – FF, with 00 to disable LOCATIONS 328 - 331 Zone Swinger Shutdown Reporting Code [#] [INSTALLER CODE] [*] [LOCATION] [*] [ZONE NUMBER] [*] [REPORTING CODE] [*] Location = 328 – 331 Zone Number = 01 – 64 Reporting code = 01 – FF, with 00 to disable LOCATIONS 332 - 335 Zone Swinger Shutdown Restore Reporting Code [#] [INSTALLER CODE] [*] [LOCATION] [*] [ZONE NUMBER] [*] [REPORTING CODE] [*] Location = 3332 – 335 Zone Number = 01 – 64 Reporting code = 01 – FF, with 00 to disable LOCATION 336 Duress Reporting Code [#] [INSTALLER CODE] [*] [3] [3] [6] [*] [PARTITION] [*] [REPORTING CODE] [*] Partition = 1 – 8 Reporting code = 01 – FF, with 00 to disable LOCATION 337 Keypad Panic Reporting Code [#] [INSTALLER CODE] [*] [3] [3] [7] [*] [PARTITION] [*] [REPORTING CODE] [*] Partition = 1 – 8 Reporting code = 01 – FF, with 00 to disable LOCATION 338 Keypad Fire Reporting Code [#] [INSTALLER CODE] [*] [3] [3] [8] [*] [PARTITION] [*] [REPORTING CODE] [*] Partition = 1 – 8

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010

20 Reporting code = 01 – FF, with 00 to disable LOCATION 339 Keypad Medical Reporting Code [#] [INSTALLER CODE] [*] [3] [3] [9] [*] [PARTITION] [*] [REPORTING CODE] [*] Partition = 1 – 8 Reporting code = 01 – FF, with 00 to disable LOCATION 340 Keypad Lockout Reporting Code [#] [INSTALLER CODE] [*] [3] [4] [0] [*] [PARTITION] [*] [REPORTING CODE] [*] Partition = 1 – 8 Reporting code = 01 – FF, with 00 to disable LOCATIONS 342 - 349 Close Reporting Code [#] [INSTALLER CODE] [*] [LOCATION] [*] [USER] [*] [REPORTING CODE] [*] Location = 342 – 349 User = 01 – 128 Reporting code = 01 – FF, with 00 to disable LOCATIONS 350 - 357 Stay Close Reporting Code [#] [INSTALLER CODE] [*] [LOCATION] [*] [USER] [*] [REPORTING CODE] [*] Location = 350 – 357 User = 01 – 128 Reporting code = 01 – FF, with 00 to disable LOCATIONS 358 - 365 Open Reporting Code [#] [INSTALLER CODE] [*] [LOCATION] [*] [USER] [*] [REPORTING CODE] [*] Location = 358 – 365 User = 01 – 128 Reporting code = 01 – FF, with 00 to disable LOCATIONS 366 - 373 Siren Cancel Reporting Code [#] [INSTALLER CODE] [*] [LOCATION] [*] [USER] [*] [REPORTING CODE] [*] Location = 366 – 373 User = 01 – 128 Reporting code = 01 – FF, with 00 to disable

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010

21 LOCATIONS 380 Clear Programmable Onboard Outputs on Disarming [#] [INSTALLER CODE] [*] [3] [8] [0] [*] [BITMAP] [*] LED Disarm Clear Output 1 Output 1 2 Output 2 3 Output 3 4 Output 4 5 Output 5 LOCATIONS 381 - 386 Clear Programmable Zone Expander Outputs on Disarming [#] [INSTALLER CODE] [*] [LOCATION] [*] [BITMAP] [*] Location = 381 – 386 LED Output 1 Output 1 2 Output 2 LOCATIONS 389 Clear Programmable Keypad Outputs on Disarming [#] [INSTALLER CODE] [*] [3] [8] [9] [*] [BITMAP] [*] LED Output 1 Keypad 1 2 Keypad 2 3 Keypad 3 4 Keypad 4 5 Keypad 5 6 Keypad 6 7 Keypad 7 8 Keypad 8 LOCATIONS 390 – 414 Partition Programmable Outputs [#] [INSTALLER CODE] [*] [LOCATION] [*] [PARTITION] [*] [OUTPUT] [ACTION] [*] Location = 390 – 414 Partition = 1 – 8 all-guides com

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010

22 Loc Event Default Output Default Action 390 Close Programmable Output Event Output 3 [03] Set High [00] 391 Stay Close Programmable Output Event Disabled [00] 392 Open Programmable Output Event Output 3 [03] Set Low [01] 393 Cancel Programmable Output Event Disabled [00] 394 Alarm Restoral Programmable Output Event Disabled [00] 395 Bypass Programmable Output Event Disabled [00] 396 Forced Arm Programmable Output Event Disabled [00] 397 Zone Tamper Programmable Output Event Disabled [00] 398 Zone Tamper Restoral Programmable Output Event Disabled [00] 399 Zone Shutdown Programmable Output Event Disabled [00] 400 Zone Shutdown Restoral Programmable Output Event Disabled [00] 401 Keypad Panic Programmable Output Event Output 1 [01] Pulse High [02] 402 Keypad Fire Programmable Output Event Output 4 [04] Pulse High [02] 403 Keypad Medical Programmable Output Event Output 5 [05] Pulse High [02] 404 Keypad Lockout Programmable Output Event Disabled [00] 405 Duress Programmable Output Event Output 1 [01] Pulse High [02] 406 Verifies Alarm Programmable Output Event Disabled [00] 407 Burglary Programmable Output Event Output 2 [02] Pulse High [02] 408 Panic Programmable Output Event Output 1 [01] Pulse High [02] 409 Fire Programmable Output Event (Refer to Error! Reference source not found.) Disabled [00] 410 Tamper Zone Programmable Output Event Disabled [00] 411 Siren Programmable Output Event Disabled [00] 412 Strobe Programmable Output Event Disabled [00] 413 Chime Programmable Output Event Disabled [00] 414 Arm Follow Programmable Output Event Disabled [00]

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010

23 Address Physical Outputs Address Physical Outputs 00 Disabled 21 Reserved 01 Onboard output 1 22 Reserved 02 Onboard output 2 23 Reserved 03 Onboard output 3 24 Reserved 04 Onboard output 4 25 Reserved 05 Onboard output 5 26 Reserved 06 Zone expander 1 output 1 27 Reserved 07 Zone expander 1 output 2 28 Reserved 08 Zone expander 2 output 1 29 Reserved 09 Zone expander 2 output 2 30 Reserved 10 Zone expander 3 output 1 31 Reserved 11 Zone expander 3 output 2 32 Reserved 12 Zone expander 4 output 1 33 Reserved 13 Zone expander 4 output 2 34 Keypad 1 output 14 Zone expander 5 output 1 35 Keypad 2 output 15 Zone expander 5 output 2 36 Keypad 3 output 16 Zone expander 6 output 1 37 Keypad 4 output 17 Zone expander 6 output 2 38 Keypad 5 output 18 Reserved 39 Keypad 6 output 19 Reserved 40 Keypad 7 output 20 Reserved 41 Keypad 8 output Value Output Action 00 Set Output High (Set) 01 Set Output Low (Reset) 02 Pulse Output High 03 Pulse Output Low NOTE: Locations 411 – 414 only have a 2-digit output and no action LOCATIONS 415 - 422 Zone Programmable Output Events [#] [INSTALLER] [*] [LOCATION] [*] [ZONE NO.] [*] [OUTPUT NUMBER] [ACTION] [*] Location = 415 – 422 Output number = same as for Locations 390 – 413 Action = same as for Locations 390 – 413 LOCATIONS 423 - 426 Global Programmable Output Events [#] [INSTALLER CODE] [*] [LOCATION] [*] [SUB-LOCATION] [*] [OUTPUT NUMBER] [*] [ACTION] [*] Location = 423 – 426 Output number = same as for Locations 390 – 413 Action = same as for Locations 390 – 413

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010

24 Loc Sub- location Event Default Output Default Action 423 1 AC Fail Programmable Output Event Disabled [00] 2 AC Restore Programmable Output Event Disabled [00] 3 Low Battery Programmable Output Event Disabled [00] 4 Low Battery Restore Programmable Output Event Disabled [00] 5 Auto Test Programmable Output Event Disabled [00] 6 Download Programmable Output Event Disabled [00] 7 Siren Tamper Programmable Output Event Disabled [00] 8 Aux 12V Trouble Programmable Output Event Disabled [00] 424 1 Reserved Disabled [00] 2 Bus-wired Peripheral Tamper Programmable Output Event Disabled [00] 3 Bus-wired Peripheral Fail Programmable Output Event Disabled [00] 4 Box Tamper Programmable Output Event Disabled [00] 5 Dedicated Panic Programmable Output Event Output [01] Pulse High [02] 6 Communication Fail Programmable Output Event Disabled [00] 7 Telephone Line Tamper Programmable Output Event Disabled [00] 8 Telephone Line Restore Programmable Output Event Disabled [00] 425 1 Reserved 2 Reserved 3 Reserved 4 Reserved 5 Reserved 6 Reserved 7 Reserved 8 Reserved 426 1 Wired Zone Expander Low Battery Programmable Output Event Disabled [00] 2 Wired Zone Expander Low Battery Restore Programmable Output Event Disabled [00] 3 Fire Sensor Power Programmable Output Event Disabled [00] No Action 4 Dual Reporting Programmable Output Event Disabled [00] No Action 5 Reserved 6 Reserved 7 Reserved 8 Reserved LOCATION 428 Onboard Output Pulse Time (default = 0002) [#] [INSTALLER CODE] [*] [4] [2] [8] [*] [OUTPUT NUMBER] [*] [MMSS] [*] Output number = 1 – 5 MMSS = 00m00s – 59m59s LOCATION 429 - 434 Zone Expander Output Pulse Time (default = 0002) [#] [INSTALLER CODE] [*] [LOCATION] [*] [OUTPUT NUMBER] [*] [MMSS] [*] Location = 429 – 434 Output number = 1 – 2

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010

25 MMSS = 00m00s – 59m59s LOCATION 437 Keypad Output Pulse Time (default = 0002) [#] [INSTALLER CODE] [*] [4] [3] [7] [*] [KEYPAD NUMBER] [*] [MMSS] [*] Keypad number = 1 – 8 MMSS = 00m00s – 59m59s LOCATION 438 Onboard Output ON Time (default = 2400) [#] [INSTALLER CODE] [*] [4] [3] [8] [*] [OUTPUT NUMBER] [*] [HHMM] [*] Output number = 1 – 5 HHMM = 00h00m – 23h59m, with 24h00m to disable LOCATION 439 - 444 Zone Expander Output ON Time (default = 2400) [#] [INSTALLER CODE] [*] [LOCATION] [*] [OUTPUT NUMBER] [*] [HHMM] [*] Location = 439 – 444 Output number = 1 – 2 HHMM = 00h00m – 23h59m, with 24h00m to disable LOCATION 447 Keypad Output ON Time (default = 2400) [#] [INSTALLER CODE] [*] [4] [4] [7] [*] [OUTPUT NUMBER] [*] [HHMM] [*] Output number = 1 – 8 HHMM = 00h00m – 23h59m, with 24h00m to disable LOCATION 448 Onboard Output OFF Time (default = 2400) [#] [INSTALLER CODE] [*] [4] [4] [8] [*] [OUTPUT NUMBER] [*] [HHMM] [*] Output number = 1 – 5 HHMM = 00h00m – 23h59m, with 24h00m to disable LOCATION 449 - 454 Zone Expander Output OFF Time (default = 2400) [#] [INSTALLER CODE] [*] [LOCATION] [*] [OUTPUT NUMBER] [*] [HHMM] [*] Location = 449 – 454 Output number = 1 – 2 HHMM = 00h00m – 23h59m, with 24h00m to disable LOCATION 457 Keypad Output OFF Time (default = 2400) [#] [INSTALLER CODE] [*] [4] [5] [7] [*] [OUTPUT NUMBER] [*] [HHMM] [*] Output number = 1 – 8 HHMM = 00h00m – 23h59m, with 24h00m to disable

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010

26 LOCATIONS 458 - 498 Output On/Off Days [#] [INSTALLER CODE] [*] [LOCATION] [*] [BITMAP] [*] Loc. Event 458 Onboard Output 1 459 Onboard Output 2 460 Onboard Output 3 461 Onboard Output 4 462 Onboard Output 5 463 Zone Expander 1, Output 1 464 Zone Expander 1, Output 2 465 Zone Expander 2, Output 1 466 Zone Expander 2, Output 2 467 Zone Expander 3, Output 1 468 Zone Expander 3, Output 2 469 Zone Expander 4, Output 1 470 Zone Expander 4, Output 2 471 Zone Expander 5, Output 1 472 Zone Expander 5, Output 2 473 Zone Expander 6, Output 1 474 Zone Expander 6, Output 2 475 Reserved 476 Reserved 477 Reserved 478 Reserved 479 Reserved 480 Reserved 481 Reserved 482 Reserved 483 Reserved 484 Reserved 485 Reserved 486 Reserved 487 Reserved 488 Reserved 489 Reserved 490 Reserved 491 Keypad 1 492 Keypad 2 493 Keypad 3 494 Keypad 4 495 Keypad 5 496 Keypad 6 497 Keypad 7 498 Keypad 8 all-guides com

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010

27 LED ON Days of the Week LED OFF Days of the Week 1 Monday 9 Monday 2 Tuesday 10 Tuesday 3 Wednesday 11 Wednesday 4 Thursday 12 Thursday 5 Friday 13 Friday 6 Saturday 14 Saturday 7 Sunday 15 Sunday All OFF (Arm Day Disabled) All OFF (Disarm Day Disabled) LOCATIONS 501 – 564 Split Reporting Zones 1 - 64 [#] [INSTALLER CODE] [*] [LOCATION] [*] [BITMAP] [*] Location = 501 – 564 LED On/Off Action LED On/Off Reporting Pair 1 ON Enable zone alarm reporting 9 ON Telephone module 2 OFF Disable zone alarm reporting OFF Telephone module 1 2 ON Enable zone alarm restore reporting 10 ON Telephone module 2 OFF Disable zone alarm restore reporting OFF Telephone module 1 3 ON Enable zone bypass reporting 11 ON Telephone module 2 OFF Disable zone bypass reporting OFF Telephone module 1 4 ON Enable zone force arm reporting 12 ON Telephone module 2 OFF Disable zone force arm reporting OFF Telephone module 1 5 ON Enable zone tamper reporting 13 ON Telephone module 2 OFF Disable zone tamper reporting OFF Telephone module 1 6 ON Enable zone tamper restore reporting 14 ON Telephone module 2 OFF Disable zone tamper restore reporting OFF Telephone module 1 7 ON Enable zone swinger shutdown reporting 15 ON Telephone module 2 OFF Disable zone swinger shutdown reporting OFF Telephone module 1 8 ON Enable zone swinger shutdown restore reporting 16 ON Telephone module 2 OFF Disable zone swinger shutdown restore reporting OFF Telephone module 1

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010

28 Default values are shaded LOCATION 571 Global Split Reporting 1 [#] [INSTALLER CODE] [*] [5] [7] [1] [*] [BITMAP] [*] LED On/Off Action LED On/Off Reporting Pair 1 ON Enable AC fail reporting 9 ON Telephone module 2 OFF Disable AC fail reporting OFF Telephone module 1 2 ON Enable communication fail reporting * 10 ON Telephone module 2 OFF Disable communication fail reporting * OFF Telephone module 1 3 ON Enable telephone line tamper reporting 11 ON Telephone module 2 OFF Disable telephone line tamper reporting OFF Telephone module 1 4 ON Enable siren fail reporting 12 ON Telephone module 2 OFF Disable siren fail reporting OFF Telephone module 1 5 ON Enable panel low battery fail reporting 13 ON Telephone module 2 OFF Disable panel low battery fail reporting OFF Telephone module 1 6 ON Enable aux 12V fuse fail reporting 14 ON Telephone module 2 OFF Disable aux 12V fuse fail reporting OFF Telephone module 1 7 ON Reserved 15 ON Reserved OFF Reserved OFF Reserved 8 ON Enable box tamper reporting 16 ON Telephone module 2 OFF Disable box tamper reporting OFF Telephone module 1 Default values are shaded * The reporting code is only supported by Contact ID or SIA, and thus will not be reported if any other format has been selected.

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010

29 LOCATION 572 Global Split Reporting 2 [#] [INSTALLER CODE] [*] [5] [7] [2] [*] [BITMAP] [*] LED On/Off Action LED On/Off Reporting Pair 1 ON Enable bus-wired peripheral tamper reporting 9 ON Telephone module 2 OFF Disable bus-wired peripheral tamper reporting OFF Telephone module 1 2 ON Enable bus-wired peripheral fail reporting 10 ON Telephone module 2 OFF Disable bus-wired peripheral fail reporting OFF Telephone module 1 3 ON Enable bus-wired peripheral low battery reporting * 11 ON Telephone module 2 OFF Disable bus-wired peripheral low battery reporting * OFF Telephone module 1 4 ON Enable AC restore reporting 12 ON Telephone module 2 OFF Disable AC restore reporting OFF Telephone module 1 5 ON Enable communications restore reporting** 13 ON Telephone module 2 OFF Disable communications restore reporting ** OFF Telephone module 1 6 ON Enable telephone line restore reporting 14 ON Telephone module 2 OFF Disable telephone line restore reporting OFF Telephone module 1 7 ON Enable siren restore reporting ** 15 ON Telephone module 2 OFF Disable siren restore reporting ** OFF Telephone module 1 8 ON Enable panel low battery restore reporting 16 ON Telephone module 2 OFF Disable panel low battery restore reporting OFF Telephone module 1 Default values are shaded * The reporting code is only supported by Contact ID, and thus will only be reported if Contact ID has been selected. * *The reporting code is only supported by Contact ID or SIA, and thus will not be reported if any other format has been selected.

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010

30 LOCATION 573 Global Split Reporting 3 [#] [INSTALLER CODE] [*] [5] [7] [3] [*] [BITMAP] [*] LED On/Off Action LED On/Off Reporting Pair 1 ON Enable aux 12V fuse restore reporting* 9 ON Telephone module 2 OFF Disable aux 12V fuse restore reporting* OFF Telephone module 1 2 ON Reserved 10 ON Reserved OFF Reserved OFF Reserved 3 ON Enable box tamper restore reporting * 11 ON Telephone module 2 OFF Disable box tamper restore reporting * OFF Telephone module 1 4 ON Enable bus-wired peripheral tamper restore reporting* 12 ON Telephone module 2 OFF Disable bus-wired peripheral tamper restore reporting* OFF Telephone module 1 5 ON Enable bus-wired peripheral fail restore reporting * 13 ON Telephone module 2 OFF Disable bus-wired peripheral fail restore reporting * OFF Telephone module 1 6 ON Enable bus-wired peripheral low battery restore reporting** 14 ON Telephone module 2 OFF Disable bus-wired peripheral low battery restore reporting** OFF Telephone module 1 7 ON Enable dedicated panic reporting 15 ON Telephone module 2 OFF Disable dedicated panic reporting OFF Telephone module 1 8 ON Enable auto test reporting 16 ON Telephone module 2 OFF Disable auto test reporting OFF Telephone module 1 Default values are shaded *The reporting code is only supported by Contact ID or SIA, and thus will not be reported if any other format has been selected. ** The reporting code is only supported by Contact ID, and thus will only be reported if Contact ID has been selected.

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010

31 LOCATION 574 Global Split Reporting 4 [#] [INSTALLER CODE] [*] [5] [7] [4] [*] [BITMAP] [*] LED On/Off Action LED On/Off Reporting Pair 1 ON Enable download reporting 9 ON Telephone module 2 OFF Disable download reporting OFF Telephone module 1 2 ON Reserved 10 ON Reserved OFF Reserved OFF Reserved 3 ON Reserved 11 ON Reserved OFF Reserved OFF Reserved 4 ON Reserved 12 ON Reserved OFF Reserved OFF Reserved 5 ON Reserved 13 ON Reserved OFF Reserved OFF Reserved 6 ON Reserved 14 ON Reserved OFF Reserved OFF Reserved 7 ON Reserved 15 ON Reserved OFF Reserved OFF Reserved 8 ON Reserved 16 ON Reserved OFF Reserved OFF Reserved Default values are shaded all-guides com

IDS X64 Quick Programming Guide 700-398-03A Issued August 2010

32 LOCATIONS 581 - 588 Split Reporting Partitions 1-8 [#] [INSTALLER CODE] [*] [LOCATION] [*] [BITMAP] [*] Location = 581 – 588 LED On/Off Action LED On/Off Reporting Pair 1 ON Enable duress reporting 9 ON Telephone module 2 OFF Disable duress reporting OFF Telephone module 1 2 ON Enable keypad panic reporting 10 ON Telephone module 2 OFF Disable keypad panic reporting OFF Telephone module 1 3 ON Enable fire reporting 11 ON Telephone module 2 OFF Disable fire reporting OFF Telephone module 1 4 ON Enable medical reporting 12 ON Telephone module 2 OFF Disable medical reporting OFF Telephone module 1 5 ON Enable keypad lockout reporting 13 ON Telephone module 2 OFF Disable keypad lockout reporting OFF Telephone module 1 6 ON Reserved 14 ON Reserved OFF Reserved OFF Reserved 7 ON Enable armed without user code reporting 15 ON Telephone module 2 OFF Disable armed without user code reporting OFF Telephone module 1 8 ON Reserved 16 ON Reserved OFF Reserved OFF Reserved Default values are shaded