Kenwood TKR-750 Programming Reference Manual

Specifications

Brand: Kenwood
Category: Radio
Model: TKR-750 (Programming Reference Manual)
File Type: PDF
File Size: —
Pages: 83

Read Online

Read the Kenwood TKR-750 Programming Reference Manual online using the built-in PDF viewer.

Text of the manual

Field Programming Reference

(FPRG) For TTK KRR--775500//885500 VVeerrssiioonn22 TTK KRR--775511//885511

All copyrights and other intellectual property rights for this technical document and relevant in-depth manuals as well as

the software described in this technical document, relevant in-depth manuals, and help texts and manuals attached to the software are owned by Kenwood Corporation. A right to use the software described in this technical document and relevant in-depth manuals is granted to a licensee by Kenwood Corporation; however, the title to and ownership of the software shall be owned by Kenwood Corporation. Refer to the help texts attached to this software for details. Kenwood Corporation does not warrant quality and performance of the software described in this technical document and relevant in-depth manuals to conform to the applicability of any use, and Kenwood Corporation shall be free from liability for any defects, damage or loss, or from any warranty to anything other than expressly described in this technical document and relevant in-depth manuals. Revision history Date Description Sep. 2005 K-USA R&D modify

Field Programming Reference (FPRG)

I CONTENTS 1 SETTING UP THE KPG-91D......................1 1.1 System Requirement ..................................... 1 1.2 Connecting to the PC ..................................... 1 1.3 Installing KPG-91D ........................................ 1 1.4 Uninstalling KPG-91D .................................... 2 2 BASIC OPERATION...................................3 2.1 Starting and Exiting ........................................ 3 2.2 Initializing the window .................................... 3 2.3 Write the Configuration Data .......................... 3 2.4 Modify the Configuration Data ....................... 3 2.5 Edit the stored Data and Write ....................... 3 2.6 Display Help ................................................... 3 3 MENU DESCRIPTION ................................4 3.1 Main Window ................................................. 4 3.1.1 Title Bar ...................................................... 4 3.1.2 Menu Bar .................................................... 4 3.1.3 Toolbar ........................................................ 4 3.1.4 Status Bar ................................................... 5 3.2 Menu Command Description ......................... 5 3.2.1 “File” Menu .................................................. 5 3.2.2 “Model” Menu .............................................. 5 3.2.3 “Edit” Menu ................................................. 5 3.2.4 “Program” Menu .......................................... 6 3.2.5 “Tools” Menu ............................................... 6 3.2.6 “Setup” Menu .............................................. 6 3.2.7 “View” Menu ................................................ 7 3.2.8 “Window” Menu ........................................... 7 3.2.9 “Help” Menu ................................................ 7 3.3 Shortcut Keys ................................................. 8 3.3.1 Menu Bar Operation ................................... 8 3.3.2 “File” Menu Operation ................................. 8 3.3.3 “Channel Information” Window ................... 8 3.3.4 “Program” Menu .......................................... 8 3.3.5 Test Mode, Tuning Mode ............................ 9 3.3.6 Help ............................................................ 9 3.3.7 Editing the Configuration Data .................... 9 4 FILE MENU...............................................10 4.1 New .............................................................. 10 4.2 Open ............................................................ 10 4.3 Save ............................................................. 10 4.4 Save As ........................................................ 11 4.5 Print .............................................................. 11 4.5.1 Print Out List ............................................. 12 4.6 Print Preview ................................................ 14 4.6.1 Toolbar of the Print Preview ..................... 14 4.7 Exit ............................................................... 15 5 MODEL MENU..........................................16 5.1 Model Information ........................................ 16 5.1.1 Model Type ............................................... 16 5.1.2 Frequency ................................................. 16 5.1.3 Optional Board .......................................... 16 6 EDIT MENU .............................................. 17 6.1 Channel Information ..................................... 17 6.1.1 Reception Frequency ................................ 17 6.1.2 Transmission Frequency .......................... 17 6.1.3 QT/DQT Decode ....................................... 17 6.1.4 QT/DQT Encode ....................................... 18 6.1.5 Channel Name .......................................... 18 6.1.6 Multi-table ................................................. 18 6.1.7 W/N ........................................................... 18 6.1.8 Power ........................................................ 19 6.1.9 Operation Mode ........................................ 19 6.1.10 Scan Add .................................................. 19 6.1.11 CW ID ....................................................... 19 6.1.12 Channel Edit Button .................................. 19 6.1.13 Channel Copy ([Shift] + [F3]) .................... 19 6.1.14 Frequency Copy ([Shift] + [F4]) ................ 20 6.1.15 QT/DQT Copy ([Shift] + [F5]) .................... 20 6.1.16 Channel Insert ([Shift] + [F9]) ................... 20 6.1.17 Channel Delete ([Shift] + [F10]) ................ 20 6.1.18 Context Menu ........................................... 21 6.2 Channel Edit Window ................................... 21 6.2.1 Reception Frequency ................................ 21 6.2.2 Transmission Frequency .......................... 22 6.2.3 QT/DQT Decode ....................................... 22 6.2.4 QT/DQT Encode ....................................... 22 6.2.5 Channel Name .......................................... 22 6.2.6 Wide/Narrow ............................................. 23 6.2.7 Encode Tone in Multiple ........................... 23 6.2.8 Operation Mode ........................................ 23 6.2.9 Multi-table (Channel Edit) ......................... 23 6.2.10 Beat Shift .................................................. 23 6.2.11 TX High Power .......................................... 23 6.2.12 QT Reverse Burst ..................................... 24 6.2.13 Scan Add .................................................. 24 6.2.14 Compander ............................................. 24 6.2.15 CW ID ....................................................... 24 6.2.16 CW ID Button ............................................ 24 6.2.17 Voice Scrambler ....................................... 24 6.2.18 Scrambler Code ........................................ 24 6.3 CW ID Window ............................................. 25 6.3.1 CW ID ....................................................... 25 6.3.2 TX Interval Time ....................................... 25 6.3.3 TX Delay Time .......................................... 25 6.3.4 CW Speed ................................................ 25 6.3.5 CW Mod. Delay Time ................................ 25 6.3.6 Audio Frequency ....................................... 25 6.3.7 TX Required in Interval ............................. 26 6.3.8 CW ID Override ........................................ 26 6.3.9 Send CW ID to RA .................................... 26 6.3.10 CW ID on Channel Change .................... 26 6.3.11 Encode with QT/DQT (CW ID) .................. 26 6.4 Optional Features Window ........................... 27 6.4.1 Optional Features 1 Tab ........................... 27 6.4.2 Optional Features 2 Tab ........................... 31

Field Programming Reference (FPRG)

Version: 1.01 6.4.3 Others Tab (Optional Features) ................34 6.5 Key Assignment Window ..............................37 6.6 Scan Information Window .............................39 6.6.1 Priority .......................................................39 6.6.2 Priority Channel .........................................39 6.6.3 Look Back Time A .....................................39 6.6.4 Look Back Time B .....................................39 6.6.5 Revert Channel .........................................39 6.6.6 Dropout Delay Time ..................................40 6.6.7 Dwell Time .................................................40 6.6.8 Off-hook Scan ...........................................40 6.7 DTMF Window .............................................41 6.7.1 DTMF Speed .............................................41 6.7.2 First Digit Delay Time ................................41 6.7.3 First Digit Time ..........................................41 6.7.4 * and # Digit Time ......................................41 6.8 “Encode/Decode Table” Window ..................42 6.8.1 Encode Code .............................................42 6.8.2 Frequency .................................................42 6.8.3 Period ........................................................42 6.8.4 Sidetone ....................................................42 6.8.5 Decode Code ............................................42 6.9 Remote Control Window ...............................43 6.9.1 PF Key Tab ...............................................44 6.9.2 AUX Input/Output Tab ...............................45 6.9.3 Remote Access with QT/DQT ...................48 6.9.4 Clear To Transpond (Remote Control) ......48 6.10 Function Port Window ..................................48 6.10.1 AUX Select Tab .........................................48 6.10.2 AUX Tab ....................................................49 6.11 Multi-table Window .......................................54 6.11.1 Decode (Multi-table) ..................................54 6.11.2 Encode (Multi-table) ..................................54 6.12 CW Message Window ..................................55 6.12.1 CW Message .............................................55 6.12.2 CW Speed .................................................55 6.12.3 CW Mod. Delay Time ................................55 6.12.4 Audio Frequency .......................................56 6.12.5 Send CW Message to RA .........................56 6.12.6 Encode with QT/DQT (CW Message) .......56 6.13 Test Frequency Window ...............................56 6.13.1 Reception, Transmission ...........................56 6.13.2 CH Paste Button ........................................57 6.14 Embedded Message Window .......................57 6.15 Embedded Message w/Password Window ..58 7 PROGRAM MENU....................................60 7.1 Read Data from Repeater ............................60 7.2 Write Data to Repeater .................................60 7.3 Test Mode Window .......................................60 7.3.1 Test Channel .............................................61 7.3.2 Test Signalling ...........................................61 7.3.3 Wide/ Narrow .............................................62 7.3.4 Beat Shift (Test Mode) ..............................62 7.3.5 Power (Test Mode) ....................................62 7.3.6 Monitor (Test Mode) ..................................62 7.3.7 Compander (Test Mode) ...........................62 7.3.8 Repeat .......................................................62 7.3.9 TX/RX Button ............................................62 7.3.10 Print Button ................................................62 7.3.11 Tuning Mode .............................................62 8 TOOLS MENU..........................................65 8.1 Radio Information Window ...........................65 8.1.1 Model Type ................................................65 8.1.2 Frequency .................................................65 8.1.3 Serial Number ...........................................65 8.1.4 Checksum .................................................65 9 SETUP MENU ..........................................66 9.1 Communication Port Window .......................66 9.2 Language File Setup Window .......................66 10 VIEW MENU.............................................67 10.1 Tree View Window ........................................67 10.2 Toolbar .........................................................67 10.3 Status Bar .....................................................67 11 WINDOW MENU ......................................68 11.1 Cascade .......................................................68 11.2 Horizontal Tile ...............................................68 11.3 Vertical Tile ...................................................68 11.4 Arrange Icons ...............................................68 11.5 Close All Windows ........................................69 11.6 Opened Window List ....................................69 12 HELP MENU ............................................70 12.1 Help Topics Window .....................................70 12.1.1 Contents Tab .............................................70 12.1.2 Index Tab ..................................................70 12.1.3 Search Tab ................................................70 12.2 About KPG-91D Window ..............................70 13 FUNCTION LIST ......................................71

Field Programming Reference (FPRG)

1 1 SETTING UP THE KPG-91D It is possible to configure various functions of the TKR- 750/850/751/851 by KPG-91D and write the configuration data into the TKR-750/850/751/851 via the PC installed KPG-91D. It also can edit and print out the configuration data via KPG-91D. 1.1 System Requirement You must prepare the following devices and operating systems to install the KPG-91D. PC IBM PC or compatible with Windows ® operating system Hard Disc 10 MB or more free hard disc spaces Memory 32 MB or more free memory CD-ROM Drive A CD-ROM drive that can be accessed directly or via Network. Monitor A monitor having the resolution of 800 x 600 pixels and 256 or more colors. Operating Systems (OS) Microsoft Windows 98 Microsoft Windows Me Microsoft Windows 2000 Microsoft Windows XP Communication port The PC must have at least one asynchronous serial communication port to communicate with the TKR-750/ 850/751/851. You can select the communication port from COM1 - COM20 ports. Connection cable It has to connect the TKR-750/850/751/851 to the PC using KPG-46 programming cable. The DB-9 pin female to DB-25 pin male gender changer may be required depending on the COM port of your PC. Note: KPG-91D may not work properly due to the insufficient resource when running it with other software. 1.2 Connecting to the PC Follow the procedures below to connect the PC to the TKR-750/850/751/851. 1. Turn the PC OFF. 2. Connect the 25-pin connector of the KPG-46 cable to one of the COM1 - 20 ports on the PC. Use the DB-9 pin female to DB-25 pin male gender changer when your PC has only 9-pin COM port. 3. Turn the PC ON. 4. Turn the TKR-750/850/751/851 OFF. 5. Connect the modular connector of the KPG-46 programming cable to the female modular connector of the repeater. 6. Turn the TKR-750/850/751/851 ON. 1.3 Installing KPG-91D Follow the procedures below to install the KPG-91D to the PC. Note: The user must have the administrative privilege in order to install the KPG-91D with Windows 2000/XP. 1. Stop running all programs on the PC (including the virus-checking program). 2. Insert the KPG-91D CD-ROM into the CD drive.

1 SETTING UP THE KPG-91D

2 Field Programming Reference (FPRG) Version: 1.01 3. You can install the KPG-91D with one of the following methods. • Double-click the CD-ROM drive icon > “setup.exe”. • Select “RUN” > “setup.exe” in the CD-ROM drive. • Click “Control Panel” > “Application addition/ removal” > “Install”. (Click “Add Programs” when using Windows 2000/XP.) The setup program displays the instructions during installation. Follow the instructions on the screen to install the software. 1.4 Uninstalling KPG-91D Follow the procedures below to uninstall KPG-91D from the PC. Note: ! You must exit the KPG-91D before uninstalling it. ! You must have the administrative privilege in order to uninstall the KPG-91D from the PC (Windows 2000/XP). ! To update the software, uninstall the old version before installing the newer version. 1. Execute the “Application addition/ removal” command in the control panel. 2. Select the “KPG-91D” from the program list. 3. Click “Application addition/ removal”. (Click “Change/ Delete Programs” when using Windows 2000/XP.)

Field Programming Reference (FPRG)

3 2 BASIC OPERATION This section describes basic operations of the KPG-91D. Note: ! The TKR-750/850 automatically enters PC mode when reading or writing the programming data. (Refer to FUNC 1.5 Mode.) ! We recommend you storing the data configured by the KPG-91D to the hard disc or the external storage device. (Refer to 4 FILE MENU.) 2.1 Starting and Exiting Select “Start” > “All programs” > “KENWOOD FPU” > “KPG-91D” in order to start the KPG-91D. Note: You can start the KPG-91D by opening the folder in which you installed the KPG-91D and double-clicking the “kpg91d.exe” file. The Main window of the KPG-91D appears. The splash logo appears in the center of the screen for a while and it automatically disappears. You can also make the logo disappear by pressing any key on the keyboard or clicking a mouse button. Select “File” > “Exit” to exit the KPG-91D. 2.2 Initializing the window Select the model type to configure. (Refer to 5 MODEL MENU.) Model name, model type, frequency bandwidth, and data file name appear on the title bar located on the top of the window. 2.3 Write the Configuration Data Follow the procedures below to edit and write the configuration data. 1. Enter all the necessary data. Select the item that you want to configure in the “Edit” menu and enter data in the window. (Refer to 6 EDIT MENU.) 2. Write the updated data to the repeater. Select “Program” > “Write Data to Repeater”. (Refer to 7 PROGRAM MENU.) 2.4 Modify the Configuration Data Follow the procedures below to edit and write the configuration data. 1. Read the configuration data from the TKR-750/850. Select “Program” > “Read Data from Repeater”. (Refer to 7 PROGRAM MENU.) 2. Edit the data on the computer. Select the item that you want to edit in the “Edit” menu and enter data in the window. (Refer to 6 EDIT MENU.) 3. Write the updated data to the TKR-750/850. Select “Program” > “Write Data to Repeater”. (Refer to 7 PROGRAM MENU.) 2.5 Edit the stored Data and Write Follow the procedures below to edit and write the configuration data. 1. Open the configuration data stored in the hard disk drive or other storage devices. Select “File” > “Open”. (Refer to 4 FILE MENU.) 2. Edit the file data on the computer. Select the item that you want to edit in the “Edit” menu and enter data in the window. (Refer to 6 EDIT MENU.) 3. Write the updated data to the TKR-750/850. Select “Program” > “Write Data to Repeater”. (Refer to 7 PROGRAM MENU.) 2.6 Display Help Click “Help” located on each window to open the “KPG- 91D HTML Help” window. (Refer to 12 HELP MENU.)

Field Programming Reference (FPRG)

4 3 MENU DESCRIPTION 3.1 Main Window The title bar, menu bar, and toolbar appear on the top of this window. The status bar appears in the lower part of this window. Figure 3-1 Main Window 3.1.1 Title Bar The title bar of the KPG-91D software shows the model name, the frequency range, and the file name of the configuration data. (Refer to 5 MODEL MENU.) Figure 3-2 Title Bar 3.1.2 Menu Bar The Menu bar allows you to configure the functions of the TKR-750/850. Click the menu title to open the pull-down list. The menu commands stored in the menu appears. (Refer to 3.2 Menu Command Description.) When the “Window” menu appears: Figure 3-3 Menu bar 1 When the “Window” menu is not shown: Figure 3-4 Menu bar 2 Note: The “Window” menu appears on the menu bar only when the function is selected in the “Edit” menu and the window of the function is displayed. 3.1.3 Toolbar Frequently used icons are shown on the Toolbar. Click the icon to execute the function. Figure 3-5 Toolbar Note: ! You can display or hide the Toolbar by selecting “View” > “Toolbar”. (Refer to 10.2 Toolbar.) ! You can drag-and-drop the Toolbar to any desired position. Table 3-1 Descriptions of the Buttons on the Toolbar Button Function New This icon is for the “New” function in the “File” menu. This function allows you to clear the current configuration data and create the new configuration data. (Refer to 4.1 New.) Open This icon is for the “Open” function in the “File” menu. This function allows you to open the configuration data stored in the hard disk or other external storage devices. (Refer to 4.2 Open.) Save This icon is for the “Save” function in the “File” menu. This function allows you to save the current configuration data to the hard disk or other external storage devices. (Refer to 4.3 Save.) Print This icon is for the “Print” function in the “File” menu. This function allows you to print out the configuration data. (Refer to 4.5 Print.) Read This icon is for the “Read Data from Repeater” function in the “Program” menu. This function allows you to read the configuration data from the TKR-750/850. (Refer to 7.1 Read Data from Repeater.) Write This icon is for the “Write Data to Repeater” function in the “Program” menu. This function allows you to write the configuration data to the TKR-751/851. (Refer to 7.2 Write Data to Repeater.) About KPG-91D This icon is for the “About KPG-91D” function in the “Help” menu. (Refer to 12.2 About KPG-91D Window.)

3 MENU DESCRIPTION

5 Field Programming Reference (FPRG) Version: 1.01 3.1.4 Status Bar The Status bar shows a serial communication port used to perform a data communication between the KPG-91D and the TKR-750/850, and the current time and date. Figure 3-6 Status Bar Note: You can display or hide the Status bar by selecting “View” > “Status Bar”. (Refer to 10.3 Status Bar.) 3.2 Menu Command Description Following are the descriptions of the Menu Commands. 3.2.1 “File” Menu Figure 3-7 “File” Menu Table 3-2 Function List of the “File” Menu 3.2.2 “Model” Menu Figure 3-8 “Model” Menu Table 3-3 Function List of the “Model” Menu 3.2.3 “Edit” Menu The functions to be displayed vary depending on the configuration in “Model Information” > “Control Standard”. (Refer to 5.1 Model Information.) Figure 3-9 “Edit” Menu Function Description New This function allows you to clear the current configuration data and create the new configuration data. (Refer to 4.1 New.) Open This function allows you to open the configuration data stored in the hard disk drive or other external storage devices. (Refer to 4.2 Open.) Save This function allows you to save the current configuration data to the hard disk or other external storage devices. (Refer to 4.3 Save.) Save As This function allows you to name the current configuration data and save it to the hard disk or other external storage devices. Print This function allows you to print out the configuration data. (Refer to 4.5 Print.) Print Preview This function allows you to view the print image of the configuration data. (Refer to 4.6 Print Preview.) Exit This function allows you to exit the KPG- 91D. (Refer to 4.7 Exit.) Function Description Model Information This function allows you to select a model type of the TKR-750/850 and the frequency bandwidth. (Refer to 5.1 Model Information.) Function Description

Field Programming Reference (FPRG)

6 3 MENU DESCRIPTION Table 3-4 Function List of the “Edit” Menu 3.2.4 “Program” Menu Figure 3-10 “Program” Menu Table 3-5 Function List of the “Program” menu 3.2.5 “Tools” Menu Figure 3-11 “Tools” Menu Table 3-6 Function List of the “Program” Menu 3.2.6 “Setup” Menu Figure 3-12 “Setup” Menu Table 3-7 Function List of the “Setup” Menu Function Description Channel Information (Channel Edit) You can configure the channel data. (Refer to 6.1 Channel Information.) Optional Features This function allows you to configure various functions to the TKR-750/850. (Refer to 6.4 Optional Features Window.) Key Assignment This function allows you to assign functions to the PF keys. (Refer to 6.5 Key Assignment Window.) Scan Information This command allows you to configure the Scan function parameters. (Refer to 6.6 Scan Information Window.) DTMF This function allows you to configure the DTMF (Dual Tone Multi Frequency) function parameters. (Refer to 6.7 DTMF Window.) Encode/Decode Table (DTMF) This function allows you to configure the DTMF Encode/Decode function parameters. (Refer to 6.8 “Encode/Decode Table” Window.) Remote Control This function allows you to configure the Air Remote function parameters. (Refer to 6.9 Remote Control Window.) Function Port This function allows you to configure the PF keys and the Auxiliary ports parameters. (Refer to 6.10 Function Port Window.) Multi-table This function allows you to configure the Encode/Decode function parameters. (Refer to 6.11 Multi-table Window.) CW Message This command allows you to configure the data relating to the CW Message. (Refer to 6.12 CW Message Window.) Test Frequency This function allows you to configure the Test Frequency used in Test Mode. (Refer to 6.13 Test Frequency Window.) Embedded Message This function allows you to configure the characters to be stored in the TKR-750/850. (Refer to 6.14 Embedded Message Window.) Embedded Message w/ Password This function allows you to configure the characters to be stored in the TKR-750/850 and the password to protect the stored characters. (Refer to 6.15 Embedded Message w/Password Window.) Function Description Read Data from Repeater This function allows you to read the configuration data from the TKR-750/850. (Refer to 7.1 Read Data from Repeater.) Write Data to Repeater This function allows you to write the configuration data to the TKR-750/850. (Refer to 7.2 Write Data to Repeater.) Test Mode This function allows you to test or adjust the TKR-750/850. (Refer to 7.3 Test Mode Window.) Function Description Radio Information This function allows you to read the Radio information from the TKR-750/850. (Refer to 8.1 Radio Information Window.) Function Description Communication Port You can assign a serial communication port used to make the data communication between the KPG-91D and the TKR-750/850 via the serial communication port of the PC. (Refer to 9.1 Communication Port Window.) Language File Setup You can select the language used in the KPG-91D. (Refer to 9.2 Language File Setup Window.)

3 MENU DESCRIPTION

7 Field Programming Reference (FPRG) Version: 1.01 3.2.7 “View” Menu Figure 3-13 “View” Menu Table 3-8 Function List of the “View” Menu 3.2.8 “Window” Menu Figure 3-14 “Window” Menu Table 3-9 Function List of the “Window” Menu 3.2.9 “Help” Menu Figure 3-15 “Help” Menu Table 3-10 Function List of the “Help” Menu Function Description Tree View This function allows you to view the contents of the “Edit” menu in the list format. (Refer to 10.1 Tree View Window.) Toolbar This function allows you to display/hide the Toolbar. (Refer to 10.2 Toolbar.) Status Bar This function allows you to display/hide the Status bar. (Refer to 10.3 Status Bar.) Function Description Cascade This function allows you to rearrange the opened windows in an overlapped fashion (cascade format). (Refer to 11.1 Cascade.) Horizontal Tile This function allows you to rearrange the opened windows in the horizontal tiles fashion. (Refer to 11.2 Horizontal Tile.) Vertical Tile This function allows you to rearrange the opened windows in the vertical tiles fashion. (Refer to 11.3 Vertical Tile.) Arrange Icons This function allows you to rearrange the icons of the minimized windows. (Refer to 11.4 Arrange Icons.) Close All Windows This function allows you to close all the opened windows. (Refer to 11.5 Close All Windows.) Opened Window List This function allows you to list all opened windows. When clicking the title of the window, the selected window re-open on the screen. (Refer to 11.6 Opened Window List.) Function Description Help Topics This function allows you to search for the help topics. (Refer to 12.1 Help Topics Window.) About KPG-91D This function allows you to view the KPG- 91D's information. (Refer to 12.2 About KPG-91D Window.)

Field Programming Reference (FPRG)

8 3 MENU DESCRIPTION 3.3 Shortcut Keys The following shortcut keys is assigned for each command of KPG-91D. 3.3.1 Menu Bar Operation Table 3-11 Shortcut Keys used in the Menu Bar 3.3.2 “File” Menu Operation Table 3-12 Shortcut Keys used in the “File” Menu 3.3.3 “Channel Information” Window Table 3-13 Shortcut Keys used in the “Channel Information” Window 3.3.4 “Program” Menu Table 3-14 Shortcut Keys used in the “Program” Menu Key Name Function [Alt] [F10] You can select the Menu Bar. The “File” menu opens in the same way as the cursor is placed on the “File” in the menu bar. [(ING1)] [(ING2)] You can select the menu title using the [(ING1)] and [(ING2)] keys after selecting the menu bar with the [Alt] key. [(ING3)] key [(ING4)] key You can open the selected menu and select the function to be executed. [Enter] key • Press the [Enter] key while selecting the menu title to open the menu. • Press the [Enter] key while the menu is opened to execute the selected function. Key Name Function [Ctrl] + [n] Perform “File” > “New”. (Refer to 4.1 New.) [Ctrl] + [o] Perform “File” > “Open”. (Refer to 4.2 Open.) [Ctrl] + [s] Perform “File” > “Save”. (Refer to 4.3 Save.) [Ctrl] + [p] Perform “File” > “Print”. (Refer to 4.5 Print.) Key Name Function [Shift] + [F3] Appear the “Channel Copy” window. You can also copy the configured channel data to the specified channel. (Refer to 6.1.13 Channel Copy ([Shift] + [F3]).) [Shift] + [F4] Appear the “Frequency Copy” window. You can copy the “Reception Frequency” data to the “Transmission Frequency” data. (Refer to 6.1.14 Frequency Copy ([Shift] + [F4]).) [Shift] + [F5] Appear the “QT/DQT Copy” window. You can copy the configuration data of the “QT/ DQT Decode” to the “QT/DQT Encode” data. (Refer to 6.1.15 QT/DQT Copy ([Shift] + [F5]).) [Shift] + [F9] Insert a new channel into the specified channel.**1 (Refer to 6.1.16 Channel Insert ([Shift] + [F9]).) [Shift] + [F10] Delete the selected channel. (Refer to 6.1.17 Channel Delete ([Shift] + [F10]).) [F11] Appear the “Channel Edit” window. (Refer to 6.1.12 Channel Edit Button, 6.2 Channel Edit Window.) Key Name Function [Ctrl] + [r] Perform “Program” > “Read Data from Repeater”. (Refer to 7.1 Read Data from Repeater.) [Ctrl] + [w] Perform “Program” > “Write Data to Repeater”. (Refer to 7.2 Write Data to Repeater.) [Ctrl] + [t] Perform “Program” > “Test Mode”. (Refer to 7.3 Test Mode Window.)

3 MENU DESCRIPTION

9 Field Programming Reference (FPRG) Version: 1.01 3.3.5 Test Mode, Tuning Mode Table 3-15 Test Mode, Tuning Mode Shortcut Keys 3.3.6 Help Table 3-16 Shortcut Keys for the Help 3.3.7 Editing the Configuration Data Table 3-17 Shortcut Keys used to Edit the Configuration Data Key Name Function [Space] Toggle between transmission and reception. (Refer to 7.3 Test Mode Window, 7.3.11 Tuning Mode.) Key Name Function [F1] Appear the “KPG-91D HTML Help” window. The help topic operating when the [F1] key is pressed is shown. Key Name Function [Tab] Jump to the other configuration item by pressing this key. [Shift] + [Tab] Go back to the previously selected configuration item by pressing these keys. [Enter] Confirm the entered value and jump to the next configuration item. [(ING3)] [(ING4)] Use these buttons as the spin buttons in the configuration items that the spin button operation is available. You can also use these buttons to select the value in the torpedoing list without displaying the list.

Field Programming Reference (FPRG)

10 4 FILE MENU 4.1 New Select “File” > “New” to create a new data file. You can clear the current configuration data and create the new data file. The default file name for a new file will be “kpg91d.dat”. Follow the procedures below to create the new data file. 1. Select “File” > “New”. A caution message appears. Figure 4-1 File New 2. You can select one of the following options. • Click “OK”. Clear the current configuration data and create a new data file. • Click “Cancel”. The current configuration data will not be cleared and a new configuration data will not be created, neither. 4.2 Open This function is to open the configuration data file stored in the hard disk or other external storage devices (file extension:.dat). Follow the procedures below to open the configuration data file. 1. Select “File” > “Open”. The “Open” window appears. Figure 4-2 File_Open_1 Select a file name to open. The embedded message appears if the selected file contains an embedded message. 2. Click “Open”. You can read the file selected at the previous step using the KPG-91D. The error message appears when the selected file contains data that is not supported by the KPG-91D. Figure 4-3 File_Open_2 4.3 Save This function is to store the current configuration data to the hard disk or other external storage devices. Follow the procedures below to store the configuration data file. 1. Select “File” > “Save”. The configuration data is stored as a new file. The warning message appears if a file with the same name exists in the destination folder.

4 FILE MENU

11 Field Programming Reference (FPRG) Version: 1.01 Figure 4-4 File Save 2. Select one of the following options. • Click “OK”. You can store the new configuration data to the storage device. • Click “Cancel”. Cancel storing the new configuration data to the storage device. 4.4 Save As This function is to name the current configuration data and store it to the hard disk or other external storage devices. Follow the procedures to store the configuration data file as a new file. 1. Select “File” > “Save As”. The “Save As” window appears. Figure 4-5 File Save As_1 2. Enter the file name and click “Save”. You can store the configuration data with the file name entered in the “File Name”. The warning message appears if a file with the same name exists in the destination folder. Figure 4-6 File_Save As_2 3. Select one of the following options. • Click “Yes”. Store the new configuration data to the storage device. • Click “No”. The new configuration data will not be stored and returns to the “Save As” window. 4.5 Print Print out the configuration data. Follow the procedures to print the configuration data file. 1. Select “File” > “Print”. The “Print Out List” window appears and you can see the KPG-91D configuration item. (Refer to 4.5.1 Print Out List.) The functions to be displayed vary depending on the configuration in “Model Information” > “Control Standard”. (Refer to 5.1 Model Information.) Figure 4-7 File_Print_1

Field Programming Reference (FPRG)

12 4 FILE MENU 2. Confirm the check box of the configuration data item that you want to print. Figure 4-8 File_Print_3 Note: The “Model” check box and the “Embedded Message” check box are checked as default configuration. 3. Click “OK”. You can print out the “KENWOOD KPG-91D Radio Programming Information”. (Refer to 4.6 Print Preview.) 4.5.1 Print Out List " Model The Configured “Model Information” is printed. (Refer to 5.1 Model Information.) " Optional Features The Configured “Optional Features” parameters are printed. (Refer to 6.4 Optional Features Window.) " Key Assignment The Configured “Key Assignment” parameters are printed. (Refer to 6.5 Key Assignment Window.) " Scan Information The configured “Scan Information” parameters are printed. (Refer to 6.6 Scan Information Window.) " DTMF The configured “DTMF” parameters are printed. (Refer to 6.7 DTMF Window.) " Encode/Decode Table The configured “Encode/Decode Table” parameters are printed. (Refer to 6.8 “Encode/Decode Table” Window.) " Remote Control The configured “Remote Control parameters are printed. (Refer to 6.9 Remote Control Window.) " Function Port The configured “Function Port” parameters are printed. (Refer to 6.10 Function Port Window.) Range Checked The Model Information parameters will be printed out. Unchecked The Model Information parameters will not be printed out. Default Checked Range Checked The “Optional Features” parameters will be printed out. Unchecked The “Optional Features” parameters will not be printed out. Default Unchecked Range Checked The “Key Assignment” parameters will be printed. Unchecked The “Key Assignment” parameters will not be printed out. Default Unchecked Range Checked The “Scan Information” parameters will be printed. Unchecked The “Scan Information” parameters will not be printed out. Default Unchecked Range Checked The “DTMF” parameters will be printed out. Unchecked The “DTMF” parameters will not be printed out. Default Unchecked Range Checked The “Encode/Decode Table” parameters will be printed out. Unchecked The “Encode/Decode Table” parameters will not be printed out. Default Unchecked Range Checked The “Remote Control” parameters will be printed out. Unchecked The “Remote Control” parameters will not be printed out. Default Unchecked Range Checked The “Function Port” parameters will be printed out. Unchecked The “Function Port” parameters will not be printed out. Default Unchecked

4 FILE MENU

13 Field Programming Reference (FPRG) Version: 1.01 " Multi-table The configure “Multi-table” parameters are printed. (Refer to 6.11 Multi-table Window.) " CW Message The configured “CW Message” parameters are printed. (Refer to 6.12 CW Message Window.) " Test Frequency The configured “Test Frequency” parameters are printed. (Refer to 6.13 Test Frequency Window.) " Embedded Message The configured “Embedded Message” parameters are printed. (Refer to 6.14 Embedded Message Window.) " Embedded Message w/Password The configured “Embedded Message w/Password” parameters are printed. (Refer to 6.15 Embedded Message w/Password Window.) " Channel Information The configured “Channel Information” parameters are printed. (Refer to 6.1 Channel Information.) " Start Channel - End Channel It is possible to choice the start channel and end channel only when the “Channel Information” check box is checked. You can select the channel to print from the channels 1 to 16. Note: The value of the “Start Channel” must be lower than the “End Channel” value. The End Channel will be equal to the Start Channel if you enter the higher value in the Start Channel than the End Channel. " CW ID It is possible to select the CW ID only when the “Channel Information” checkbox is checked. You can configure the CW ID parameters to print. (Refer to 6.3 CW ID Window.) " “Print Setup” Button Click “Print Setup” to view the “Print Setup” window. You can configure the printer used to print out the configuration data, the paper size, and the paper rotation. " “Print Preview” Button Click “Print Preview” to view the “Print Preview” window. (Refer to 4.6 Print Preview.) Range Checked The “Multi-table” parameters will be printed out. Unchecked The “Multi-table” parameters will not be printed out. Default Unchecked Range Checked The “CW Message” parameters will be printed out. Unchecked The “CW Message” parameters will not be printed out. Default Unchecked Range Checked The “Test Frequency” parameters will be printed out. Unchecked The “Test Frequency” parameters will not be printed out. Default Unchecked Range Checked The “Embedded Message” parameters will be printed out. Unchecked The “Embedded Message” parameters will not be printed out. Default Checked Range Checked The “Embedded Message w/ Password” parameters will be printed. Unchecked The “Embedded Message w/ Password” parameter will not be printed out. Default Unchecked Range Checked The “Channel Information” parameters will be printed out. Unchecked The “Channel Information” parameters will not be printed out. Default Unchecked Range Start Channel End Channel 1 - 16 (Channel) 1 - 16 (Channel) Default 1 16 Range Checked The CW ID parameters will be printed out. Unchecked The CW ID parameters will not be printed out. Default Unchecked

Field Programming Reference (FPRG)

14 4 FILE MENU " “Clear All” Button Click “Clear All” to uncheck all checkbox. " “Select All” Button Click “Select All” to check all checkbox. " Total Pages The total number of pages appears. 4.6 Print Preview Review the print image after selecting items to be printed in the Print Out List. Follow the procedures below to view the print image. 1. You can select one of the following operations. • Select “File” > “Print Preview”. • Click “Print Preview” in the “Print Out List” window. (Refer to 4.5.1 Print Out List.) The “Print Preview” window appears. It can switch the display and move to the other page by clicking the buttons on the toolbar located on the top of the window. (Refer to 4.6.1 Toolbar of the Print Preview.) Figure 4-9 Print Preview 4.6.1 Toolbar of the Print Preview Figure 4-10 Print Preview_Toolbar " “Print” button Click “Print” to view the “Print Out List” window. " “Next Page”/”Prev Page” button Click “Next Page” to view the next page of the current print image. Click “Prev Page” to view the previous page of the current print image. Note: ! You can click the “Next Page” only when there are more than one page(s). ! You can click the “Prev Page” only when there are preceding page(s). " “Two Page”/”One Page” Button Click “Two Page” to display two pages at the same time. Click “One Page” when two pages are displayed in order to display only one page. " “Zoom In”/”Zoom Out” Button Click “Zoom In” to enlarge the print image. Click “Zoom Out” to zoom out the print image. Note: ! You can click the “Zoom In” button only when the print image can be enlarged. ! You can click the “Zoom Out” button only when the print image can be zoomed out. ! You can enlarge the print image when the magnifying glass icon appears on the image. You can zoom out the print image when the cursor returns to normal. " “Close” Button Click “Close” to close the “Print Preview” window and return to the main window or the “Print Out List” window.

4 FILE MENU

15 Field Programming Reference (FPRG) Version: 1.01 4.7 Exit This function is to exit the KPG-91D program. Follow the procedures below to exit the KPG-91D. 1. Select “File” > “Exit”. The confirmation dialog box appears to exit the KPG- 91D. Figure 4-11 File_Exit_1 2. Select one of the following options. • Click “No”. Click “No” if you do not want to exit the KPG-91D. • Click “Yes”. Immediately exit the KPG-91D program by pressing “Yes” when the configuration data has not been modified or already stored. The confirmation dialog box appears to ask you to store the configuration data if you have modified it. Figure 4-12 File_Exit_2 3. Select one of the following options. • Click “Cancel”. The exit is canceled. • Click “No”. Exit the KPG-91D program without storing the configuration data to the storage device. • Click “Yes”. The “Save As” window (refer to 4.4 Save As) appears and you can store the configuration data to a file. You can exit the KPG-91D program after storing the data.

Field Programming Reference (FPRG)

16 5 MODEL MENU 5.1 Model Information You can select the TKR-750/850/751/851 model type, market code, frequency, and the option board on the “Model Information” window. Figure 5-1 “Model Information” window 5.1.1 Model Type Select the TKR-750/850/751/851 model type model type from dropdown list. 5.1.2 Frequency Select the frequency bandwidth according to the model type from dropdown list. Table 5-1 Transmission/Reception Frequency Range Note: ! A warning message appears when clicking “OK” after changing “Model Type” or “Frequency” (Figure 5-2). Click “OK” to delete all configured data and create a new data with the selected Model Type or the transmission/reception frequency. Click “Cancel” to return to the “Model Information” window without changing the model type and the transmission/reception frequency. Figure 5-2 Model Information_Warning_1 ! 406.0 MHz and 406.1MHz are assigned as the Emergency locator beacons in the United States. Therefore, the TKR-750/ 751/850/851 is not designed to use these frequencies. 5.1.3 Optional Board Select the optional board installed in the TKR-750/850/ 751/851 from dropdown list. Select “None” if no Voice Scrambler board is installed. Range TKR-750, TKR-850, TKR-751, TKR-851 Default TKR-750 Model Market Code Frequency Range [MHz] TKR-750 K K2 146 - 174 136 - 150 TKR-850 K K2 K3 450 - 480 480 - 512 400 - 430 TKR-751 K 146 - 174 TKR-851 K K2 450 - 480 480 - 512 Range None No optional board is installed. Voice Scrambler The Voice Scrambler board is installed. Default None

Field Programming Reference (FPRG)

Version: 1.01 6 EDIT MENU 6.1 Channel Information It can configure the channel data to transmit/receive on the “Channel Information” window. You can configure the data a maximum of 16 channels. Figure 6-1 Channel Information window 6.1.1 Reception Frequency It can configure the Reception Frequency in this window. You can directly enter the value in the edit box. Note: ! The frequency range varies depending on the model and the market code. (Refer to FUNC 1.2 Transmission/Reception Frequency.) ! You can use numbers, “.”, and “,” for the 9 digits of the frequency. ! You must enter the value within the range when configuring the frequency. When entering the frequency, which is out of the range, it will be automatically replaced with the highest value or the lowest value within the range configured in “Model Information” > “Frequency” window. (Refer to 5.1 Model Information.) ! You must configure the “Reception Frequency” first before configuring other functions. On the other hand, the other functions are reset when clearing the frequency configured in the “Reception Frequency” window. 6.1.2 Transmission Frequency You can configure the Transmission Frequency in this window. You can directly enter the value in the edit box. Note: ! The frequency range varies depending on the model and the market code. (Refer to FUNC 1.2 Transmission/Reception Frequency.) ! You can use numbers, “.”, and “,” for the 9 digits of the frequency. ! You must enter the value within the range when configuring the frequency. When entering the frequency, which is out of the range, it will be automatically replaced with the highest value or the lowest value within the range configured in “Model Information” > “Frequency” window. (Refer to 5.1 Model Information.) 6.1.3 QT/DQT Decode It can configure the signalling used to receive a call. You can select the QT tone or DQT code from the dropdown list. You can also directly enter the QT tone and the DQT code. Note: ! When both of the QT Encode and the QT Reverse Burst functions are enabled, the repeater transmits the QT Reverse Burst tone at end of transmission. ! When the DQT Encode is selected, the TKR-750/850/751/851 transmits the DQT Turn-off Code. # Selecting the QT/DQT Decode Code from the Dropdown list: # Directly entering the QT/DQT Decode Code: Note: ! You can use numbers, “D”, “N”, “I”, “.”, and “,” for the 5 digits of the QT/DQT Encode code. ! When entering only numbers, the code is automatically configured as the QT Tone. ! When entering “D” as the first character of the code, the code is automatically configured as the DQT code. ! When entering the value, which is out of the range, it will be automatically replaced with the highest value or the lowest value in the range. Range TKR-750/751 100.00000 - 280.00000 MHz TKR-850/851 327.00000 - 550.00000 MHz (Common to all ranges) Default Blank Range TKR-750/751 100.00000 - 280.00000 MHz TKR-850/851 327.00000 - 550.00000 MHz (Common to all ranges) Default Blank Range QT 67.0 - 250.3 Hz DQT Normal D023N - D754N DQT Inverse D023I - D754I Default None Range QT 67.0 - 254.1 Hz DQT Normal D000N - D777N DQT Inverse D000I - D777I In steps of QT 0.1 Hz DQT 1 Default None

Field Programming Reference (FPRG)

18 6 EDIT MENU 6.1.4 QT/DQT Encode It can configure the signalling for the transmission. You can select the QT tone or DQT code from the dropdown list. You can also directly enter the QT tone and the DQT code. # Selecting the QT/DQT Encode Code from the Dropdown list: # Directly Entering the QT/DQT Encode Code: Note: ! You can use numbers, “D”, “N”, “I”, “.”, and “,” for the 5 digits of the QT/DQT Encode code. ! When entering only numbers, the code is automatically configured as the QT Tone. ! When entering “D” as the first character of the code, the code is automatically configured as the DQT code. ! When entering the value, which is out of the range, it will be automatically replaced with the highest value or the lowest value in the range. 6.1.5 Channel Name It can configure the name of the channel. The configured Channel Name appears on the Channel/Status display when selecting the channel with the PF key. (Refer to FUNC 1.6 Display.) Note: The TKR-750/850/751/851 may not properly recognize the entered characters when entering the reserved characters, such as “PG”, “E1”,”E2”, “E3”, “E4”. Do not use the reserved characters for the channel name. 6.1.6 Multi-table It can select whether or not the TKR-750/850/751/851 waits for a call with the QT/DQT Decode code configured to each channel and the QT/DQT Decode code configured in the Multi-table. This function is available only when the QT/DQT Decode code is configured on the “Channel Information” window and the Decode code is configured on the Multi-table. (Refer to 6.11 Multi-table Window.) Note: ! The signalling encoded when the PTT switch is pressed depend on configuration of the “Encode Tone in Multiple” of the “Channel Edit” window. (Refer to 6.2.7 Encode Tone in Multiple.) ! Do not configure the same QT/DQT Decode data in the Multi- table. When one or more same QT/DQT Decode data are configured in the Multi-table and the QT/DQT Encode data are different, the repeater cannot specify the QT/DQT Encode data to be transmitted. 6.1.7 W/N It can configure the transmission bandwidth for each channel. Select the bandwidth from Wide and Narrow from the dropdown list. (Refer to FUNC 1.4 Transmission Bandwidth.) Range QT 67.0 - 250.3 Hz DQT Normal D023N - D754N DQT Inverse D023I - D754I Default None Default QT 67.0 - 254.1 Hz DQT Normal D000N - D777N DQT Inverse D000I - D777I In steps of QT 0.1 Hz DQT 1 Default None Range 2 digits 0 ~ 9, A, b, c, d, E, F, G, H, i, J, L, n, o, P, q, r, S, t, U, y, -, =, _ Default Channel Number (1 - 16) Range Yes, No Default No Range Wide, Narrow Default Wide

6 EDIT MENU

19 Field Programming Reference (FPRG) Version: 1.01 6.1.8 Power It can configure the Transmission Power for each channel. Select “High” or “Low” from the dropdown list. It is possible to configure the Transmission Power only when the Transmission Frequency is configured. (Refer to 6.1.2 Transmission Frequency.) 6.1.9 Operation Mode It can configure the Operation Mode for each channel. Select the mode from Repeat, Simplex, and Duplex from the dropdown list. Note: ! When the reception frequency is same as the transmission frequency, the Operation Mode is fixed to Simplex mode, so that you cannot select “Repeat” or “Duplex”. ! You cannot enable the “Scan Add” when “Repeat” is selected since the channel has a fixed frequency pair. (Refer to 6.1.10 Scan Add.) 6.1.10 Scan Add You can select the channel to be scanned. Select “Yes” or “No” from the dropdown list. Note: You cannot enable the Scan Add function when selecting “Repeat” in the “Operation Mode” since the channel is fixed to operate the repeater mode. (Refer to 6.1.9 Operation Mode.) 6.1.11 CW ID It can select the repeater to send the CW ID. Select “Yes” or “No” from the dropdown list. Note: ! You cannot send a CW ID while scanning or Scan pauses. ! When “CW ID On” or “CW Message On” is enabled while sending the CW ID, the TKR-750/850/751/851 stops sending the current CW ID and sends the new CW ID instead. 6.1.12 Channel Edit Button Click “Channel Edit” to view the “Channel Edit” window. (Refer to 6.2 Channel Edit Window.) Note: You can open the “Channel Edit” window with one of the following options. • Press [F11]. • Double-click the channel number. 6.1.13 Channel Copy ([Shift] + [F3]) It can copy a configured channel data to the other channel. Follow the procedures given below to copy a channel. 1. Select the channel to copy. You can select the channel by clicking the channel number. 2. Press [Shift] and [F3] at the same time. The “Channel Copy” window appears. Figure 6-2 Channel Copy window 3. Select a channel to be copied. You can select the channel with the spin buttons. You can also directly enter the channel number. 4. Click “Copy”. The configuration data is copied to the desired channel. Note: You can copy the configuration data only when the source channel has the configuration data. Range High, Low Default High Range Repeat, Simplex, Duplex Default When the transmission frequency is not same as the reception frequency: Repeat When the transmission frequency is same as the reception frequency: Simplex Range Yes, No Default No Range Yes, No Default No

Field Programming Reference (FPRG)

20 6 EDIT MENU 6.1.14 Frequency Copy ([Shift] + [F4]) It can copy the data configured in the “Reception Frequency” to the “Transmission Frequency” of the same channel. Follow the procedures given below to copy the frequency. 1. Select the channel to copy. You can select the channel by clicking the channel number. 2. Press [Shift] + [F4]. The “Frequency Copy” window appears. Figure 6-3 Frequency Copy window 3. Click “Copy”. The data configured in the “Reception Frequency” is copied to the “Transmission Frequency” of the same channel. Note: ! When directly entering the frequency in the “Frequency Copy” window, the entered frequency is used as the “Transmission Frequency”. ! You cannot copy the “Reception Frequency” data to other channels. ! You can copy the configuration data only when the source channel has the Reception Frequency data. 6.1.15 QT/DQT Copy ([Shift] + [F5]) It can copy the data configured in the “QT/DQT Decode” to the “QT/DQT Encode” of the same channel. Follow the procedures given below to copy the QT/DQT code. 1. Select the channel to copy. You can select the channel by clicking the channel number. 2. Press [Shift] + [F5]. You can view the “QT/DQT Copy” window. Figure 6-4 QT/DQT Copy window 3. Click “Copy”. You can copy the data configured in the “QT/DQT Decode” to the “QT/DQT Encode” of the same channel. Note: ! When directly entering the QT/DQT Encode code in the “QT/ DQT Copy” window or selecting it from the dropdown list, the entered value is used as the “QT/DQT Encode”. ! You cannot copy the “QT/DQT Decode” configuration data to other channels. ! You can copy the configuration data only when the source channel has the QT/DQT Decode configuration data. 6.1.16 Channel Insert ([Shift] + [F9]) It can insert a new channel to the channel list. Follow the procedures below to insert the channel. 1. Select one of the channels to insert a new channel. You can select the channel by clicking the channel number. 2. Press [Shift] and [F9] at the same time. The new channel is inserted on top of the selected channel. The channel number of the channels following the inserted channel increases in steps of 1. Note: You cannot insert a new channel when the data is configured to the last channel (No. 16). 6.1.17 Channel Delete ([Shift] + [F10]) It can delete channel data. Follow the procedures given below to delete the channel data. 1. Select the channel to delete. You can select the channel by clicking the channel number. 2. Press [Shift] + [F10] at the same time. The selected channel is deleted. The channel number of the channels following the deleted channel decreases in steps of 1.

6 EDIT MENU

21 Field Programming Reference (FPRG) Version: 1.01 6.1.18 Context Menu Select the channel by clicking the channel number and right-click to display the context menu of the selected channel. In this menu, you can copy or delete the configuration data. Figure 6-5 Context Menu Table 6-1 Context Menu 6.2 Channel Edit Window It can configure the channel data to transmit/receive on the “Channel Edit” window. You can configure data of maximum 16 channels. You can configure the Encode Tone in Multiple, Beat Shift, QT Reverse Burst, Compander, CW ID, and Voice Scrambler functions. Figure 6-6 Channel Edit window 6.2.1 Reception Frequency It can configure the Reception Frequency to directly enter the value in the edit box. Note: ! The frequency range varies corresponding to the model and the market code. (Refer to FUNC 1.2 Transmission/Reception Frequency.) ! You can use numbers, “.”, and “,” for the 9 digits of the frequency. ! You must enter the value within the range when configuring the frequency. When entering the frequency, which is out of the range, it will be automatically replaced to the highest value or the lowest value within the range configured in “Model Information” > “Frequency” window. (Refer to 5.1 Model Information.) ! You must configure the “Reception Frequency” first before configuring other functions. On the other hand, the other functions resets when deleting the frequency data configured in the “Reception Frequency” window. Function Description Copy Copy the selected channel. Paste Paste the copied channel data. Delete Delete the selected channel. to Clipboard Copy the selected channel data to the clipboard. to Clipboard (w/ Title) You can copy the selected channel data to the clipboard with the title. Range TKR-750/751 100.00000 - 280.00000 MHz TKR-850/851 327.00000 - 550.00000 MHz Default Blank

Field Programming Reference (FPRG)

22 6 EDIT MENU 6.2.2 Transmission Frequency It can configure a Frequency to transmit. Enter a value in the edit box. directly Note: ! The frequency range varies depending on the model and the market code. (Refer to FUNC 1.2 Transmission/Reception Frequency.) ! It can use numbers, “.”, and “,” for the 9th digit of the frequency. ! You must enter the value within the range when configuring the frequency. When entering the frequency, which is out of the range, it will be automatically replaced with the highest value or the lowest value within the range configured in “Model Information” > “Frequency” window. (Refer to 5.1 Model Information.) 6.2.3 QT/DQT Decode It can configure a signalling to receive a call. Select a QT tone or DQT code from the dropdown list. You can also directly enter the QT tone and the DQT code. Note: ! When both of the QT Encode and the QT Reverse Burst functions are enabled, the TKR-750/850/751/851 transmits a QT Reverse Burst code at end of transmission. ! When the DQT Encode is selected, the TKR-750/850/751/851 transmits a DQT Turn-off Code. # Selecting the QT/DQT Decode Code from the Dropdown List: # Directly entering the QT/DQT Decode Code: Note: ! You can use numbers, “D”, “N”, “I”, “.”, and “,” for the 5th digit of the QT/DQT Encode code. ! When entering only numbers, the code is automatically configured as the QT Tone. ! When entering “D” as the first character of the code, the code is automatically configured as the DQT code. ! When entering the value, which is out of the range, it will be automatically replaced with the highest value or the lowest value in the range. 6.2.4 QT/DQT Encode It can configure a signalling to make a call. You can select a QT tone or DQT code from the dropdown list. You can also directly enter the QT tone and the DQT code. # Selecting the QT/DQT Encode Code from the Dropdown list: # Directly entering the QT/DQT Encode Code: Note: ! You can use numbers, “D”, “N”, “I”, “.”, and “,” for the 5 digits of the QT/DQT Encode code. ! When entering only numbers, the code is automatically configured as the QT Tone. ! When entering “D” as the first character of the code, the code is automatically configured as the DQT code. ! When entering the value, which is out of the range, it will be automatically replaced with the highest value or the lowest value in the range. 6.2.5 Channel Name It can configure the Channel Name. The configured channel name appears on the Channel/Status display when selecting the channel with the PF key. (Refer to FUNC 1.6 Display.) Range TKR-750/751 100.00000 - 280.00000 MHz TKR-850/851 327.00000 - 550.00000 MHz (Common to all ranges) Default Blank Range QT 67.0 - 250.3 Hz DQT Normal D023N - D754N DQT Inverse D023I - D754I Default None Range QT 67.0 - 254.1 Hz DQT Normal D000N - D777N DQT Inverse D000I - D777I In steps of QT 0.1 Hz DQT 1 Default None Range QT 67.0 - 250.3 Hz DQT Normal D023N - D754N DQT Inverse D023I - D754I Default None Range QT 67.0 - 254.1 Hz DQT Normal D000N - D777N DQT Inverse D000I - D777I In steps of QT 0.1 Hz DQT 1 Default None Range 2 digits 0 - 9, A, b, c, d, E, F, G, H, i, J, L, n, o, P, q, r, S, t, U, y, -, =, _ Default Channel Number (1 - 16)

6 EDIT MENU

23 Field Programming Reference (FPRG) Version: 1.01 Note: The TKR-750/850/751/851 may not properly recognize the entered characters when entering the reserved characters, such as “PG”, “E1”,”E2”, “E3”, “E4”. Do not use the reserved characters for the channel name. 6.2.6 Wide/Narrow It can configure the transmission bandwidth for each channel. Select the bandwidth from Wide and Narrow from the dropdown list. (Refer to FUNC 1.4 Transmission Bandwidth.) 6.2.7 Encode Tone in Multiple It can select a signalling to transmit when the TKR-750/850/ 751/851 receives the transmission request on the channel operating other than Simplex Mode. You can select “Primary” or “Current” from the dropdown list. Note: ! It cannot select “Current” in the “Encode Tone in Multiple” when the “Operation Mode” is configured to “Simplex”. (Refer to 6.2.8 Operation Mode.) ! The encode operation varies according to the PTT priority and the TKR-750/850/751/851 status. (Refer to FUNC 4.7 Encode Tone in Multiple.) 6.2.8 Operation Mode It can configure the operation mode for each channel. You can select a mode from Repeat, Simplex, and Duplex from the dropdown list. Note: ! When a reception frequency is same as a transmission frequency, the operation mode is fixed to Simplex, so that you cannot select “Repeat” or “Duplex”. ! You cannot enable “Scan Add” when selecting “Repeat” since the channel has a fixed frequency pair. (Refer to 6.2.13 Scan Add.) 6.2.9 Multi-table (Channel Edit) It can enable that the TKR-750/850/751/851 waits a call with a QT/DQT Decode code in the Multi-table. This function is available only when the QT/DQT Decode code is configured on the “Channel Information” window and the Decode code is configured in the Multi-table. (Refer to 6.11 Multi-table Window.) Note: ! The signalling, which is encoded when the PTT switch is pressed, is depend on the “Encode Tone in Multiple” configuration on the “Channel Edit” window. (Refer to 6.2.7 Encode Tone in Multiple.) ! Do not configure the same QT/DQT Decode data in the Multi- table. When one or more same QT/DQT Decode data are configured in the Multi-table and the QT/DQT Encode data are different, the TKR-750/850/751/851 cannot specify the QT/DQT Encode data to be transmitted. 6.2.10 Beat Shift It can enable/disable the Beat Shift. The Beat Shift function eliminates the problems of the TKR-750/850/751/ 851 internal beat caused by internal oscillators. The harmonic of the microprocessor clock may interfere to reception. You can eliminate this problem by slightly shifting the frequency of the clock used in the microprocessor. 6.2.11 TX High Power It can configure the Transmission Power for each channel. Select “High” or “Low”. You can configure the Transmission Power only when the Transmission Frequency is configured. (Refer to 6.2.2 Transmission Frequency.) Range Wide, Narrow Default Wide Range Primary: Encodes the Primary code configured to each channel. Current: Encodes the QT/DQT Encode code configured to the “Multi-table”. Default Primary Range Repeat, Simplex, Duplex Default When the transmission frequency is not the same as the reception frequency: Repeat When the transmission frequency is the same as the reception frequency: Simplex Range Checked The Multi-table function is enable. Unchecked The Multi-table function is disabled. Default Unchecked Range Checked The Beat Shift function is enabled. Unchecked The Beat Shift function is disabled. Default Unchecked Range Checked The transmission output power is configured to “High”. Unchecked The transmission output power is configured to “Low”. Default Checked

Field Programming Reference (FPRG)

24 6 EDIT MENU 6.2.12 QT Reverse Burst It can enable/disable the QT Reverse Burst function. This function eliminates a squelch tail noise on the receiving side since the QT Reverse Burst tone is sent at end of transmitting. When the QT/DQT Encode code configured to the channel is QT, the QT Reverse Burst Code is transmitted. Note: When the DQT Encode is selected, the TKR-750/850/751/ 851 transmits the QT Turn-off Code. 6.2.13 Scan Add It can select a channel to be scanned. Note: You cannot enable the Scan Add function when selecting “Repeat” in the “Operation Mode” since the channel is fixed to operate the repeater mode. (Refer to 6.2.8 Operation Mode.) 6.2.14 Compander It can enable/disable Compander. This function improves the quality of the received audio by reducing the noise. Compander is used to improve the S/N ratio (Signal to Noise Ratio) of an audio signal by compressing it at the transmitting side and expanding it at the receiving side. With this function, the TKR-750/850/751/851 compresses the transmission signal during transmission and it expands the signal with the same ratio during reception. Note: ! Compander does not operate on the audio signal to be repeated. ! To use Compander, both the transmitting party's configuration and the receiving party's configuration must be the same. 6.2.15 CW ID It can configure the TKR-750/850/751/851 to send a CW ID. Check the “CW ID” checkbox to enable. (Refer to 6.2.16 CW ID Button.) Note: ! It cannot send a CW ID while scanning or the Scan pauses. ! When “CW ID On” or “CW Message On” is enabled while sending the CW ID, the repeater stops sending the current CW ID and sends the new CW ID instead. 6.2.16 CW ID Button It can use the “CW ID” button only when CW ID is enabled. Click this button to view the “CW ID” window. (Refer to 6.3 CW ID Window.) 6.2.17 Voice Scrambler You can enable/disable Voice Scrambler. You must install the optional Voice Scramble board in the TKR-750/850/ 751/851 and select “Model Information” > “Option Board” > “Voice Scrambler” in order to use the Voice Scrambler. Note: The audio of repeat is not scrambled even if this function is enabled. 6.2.18 Scrambler Code It can configure the Scrambler Code. You must install the optional Voice Scramble board and select “Model Information” > “Option Board” > “Voice Scrambler” in order to configure the Scramble Code. Note: When the The TKR-750/850/751/851 is turned ON or the channel is changed, the code selection ports specify the configured Scrambler code regardless of the status of Voice Scrambler. (Refer to FUNC 4.14.1 Scrambler Code. Range Checked The QT Reverse Burst function is enabled. Unchecked The QT Reverse Burst function is disabled. Default Checked Range Checked The Scan operation is enabled. Unchecked The Scan operation is disabled. Default Unchecked Range Checked Compander is enabled. Unchecked Compander is disabled. Default Unchecked Range Checked CW ID is enable Unchecked CW ID is Disable Default Unchecked Range Checked Voice Scrambler is enabled. Voice Scrambler is enabled when TKR-750/850/751/851 is turned ON or the channel is changed. Unchecked Voice Scrambler is disabled. Voice Scrambler is disabled when TKR-750/850/751/851 is turned ON or the channel is changed. Default Unchecked Range 1 - 16 In steps of 1 Default 1

6 EDIT MENU

25 Field Programming Reference (FPRG) Version: 1.01 6.3 CW ID Window It can configure a CW ID to send. Figure 6-7 CW ID window 6.3.1 CW ID It can configure a CW ID by entering a maximum of 32 characters and symbols. (Refer to 6.3 CW ID Window.) 6.3.2 TX Interval Time It can configure the interval time to transmit the CW ID. You can configure a duration using the spin buttons or directly enter a value to configure the duration. Note: The TX Interval Time starts counting down when resetting the TKR-750/850/751/851, changing the channel, and activating the “CW ID On” Function or the “Scan Off” Function. 6.3.3 TX Delay Time TX Delay Time is a duration between the time when the transmission ends due to the expiration of the TX Interval Time, the change of the channel, or the deactivation of the CW ID Override function and the time when the TKR- 750/850/751/851 resumes transmitting in order to send the CW ID. You can configure the duration using the spin buttons or directly enter the value. (Refer to 6.3.2 TX Interval Time.) The CW ID is sent after the CW Mod. Delay Time is expired. (Refer to 6.3.5 CW Mod. Delay Time.) Note: “TX Delay Time” function is not applicable when sending the CW ID with the “CW ID On” function. 6.3.4 CW Speed It can configure a interval duration to send the CW ID. You can configure the speed using the spin buttons or directly enter the value. 6.3.5 CW Mod. Delay Time It can configure a duration between the time when the TKR-750/850/751/851 starts transmitting and the time when it sends a CW ID. You can configure the duration using the spin buttons or directly enter the value. 6.3.6 Audio Frequency It can configure a frequency to send the CW ID. You can configure the frequency using the spin buttons or directly enter the value to configure the duration. Range A maximum of 32 characters and symbols (space), “, ', (,), +,,, -,., /, 0, 1, 2, 3, 4, 5, 6, 7, 8, 9,:, =,? A - Z Default Blank Range 1 - 60 min. In steps of 1 min. Default 30 min. Range Off, 0.1 - 10 sec. In steps of 0.1 sec. Default 5 sec. Range 5 - 30 word/min. In steps of 1 word/min. Default 20 word/min. Range Off, 10 - 2550 ms In steps of 10 ms Default 600 ms Range 400 - 2000 Hz In steps of 100 Hz Default 800 Hz

Field Programming Reference (FPRG)

26 6 EDIT MENU 6.3.7 TX Required in Interval It can be enable to send a CW ID with the configured interval. (Refer to 6.3.2 TX Interval Time.) Note: “TX Required in Interval” function is not applicable when sending the CW ID with the “CW ID On” function. 6.3.8 CW ID Override It can send a CW ID with audio signal when the TX Interval Time expires during transmission. (Refer to 6.3.2 TX Interval Time.) Note: ! When sending the CW ID configured as CW ID Override On, the QT/DQT code configured to the channel is encoded regardless of the Encode with QT/DQT configuration. (Refer to 6.3.11 Encode with QT/DQT (CW ID).) ! The CW ID is not sent even when the CW ID On function is enabled during transmission while CW ID Override is disabled. 6.3.9 Send CW ID to RA A CW ID tone is sent to the front speaker and the RA terminal located on the rear panel. It can use to monitor and confirm by dispatcher. Note: The CW ID is only sent from the RA line when the channel is in Simplex mode. In this case, the CW ID is not sent from the speaker. 6.3.10 CW ID on Channel Change It can transmit a CW ID when the channel is selected or changed. The TKR-750/850/751/851 transmits a CW ID regardless of the configuration of the CW Mod. Delay Time and the TX Interval Time. 6.3.11 Encode with QT/DQT (CW ID) It can encode a QT/DQT (Primary) code configured to each channel while sending a CW ID. Note: The TKR-750/850/751/851 sends the QT/DQT code configured to each channel when Encode with QT/DQT is enabled, and it does not send the QT/DQT code when Encode with QT/DQT is disabled. However, the new CW ID/ CW Message is sent in conjunction with the Encode with QT/DQT configuration when the TKR-750/850/751/851 sends another CW ID or CW Message while the CW ID is independently sent. (Refer to 6.12 CW Message Window.) Range Checked The CW ID is sent after the configured interval timer expires only when TKR-750/850/751/851 transmitted. Unchecked The CW ID is sent with the interval configured in the “TX Interval Time”. Default Unchecked Range Checked The CW ID is sent with an audio signal when the TX Interval Time expires during transmission. Unchecked The CW ID is sent after the transmission ends when the TX Interval Time expires during transmission. Default Unchecked Range Checked “Send CW ID to RA” is enable Unchecked “Send CW ID to RA” is disable Default Unchecked Range Checked CW ID is sent when the channel is selected or changed. Unchecked CW ID is not sent even when the channel is selected or changed. Default Unchecked Range Checked CW ID is transmitted with QT/DQT (Primary) code of each channel. Unchecked CW ID is transmitted without QT/ DQT (Primary) code of each channel. Default Unchecked

6 EDIT MENU

27 Field Programming Reference (FPRG) Version: 1.01 6.4 Optional Features Window On this window, it can configure the transmission/ reception condition and the repeater's operation during transmission/reception. You can also configure the functions in conjunction with some operation status. This window consists of “Optional Features 1", “Optional Features 2", “Others” tabs and you can switch the display by clicking tabs. 6.4.1 Optional Features 1 Tab On this tab, it can configure the transmission/reception using the repeater PTT or the external PTT and the repeater's operation during transmission/reception. Figure 6-8 Optional Features 1 tab " Time-out Timer (TOT) (Repeater/Ext-PTT) You can configure a duration of the continuous transmission using the repeater PTT or the external PTT. The TKR-750/850/751/851 automatically stops transmission and returns to the reception mode when the TOT expires. Configure a duration time by the spin buttons or directly enter the value. Note: The TOT function is not applicable to send the CW ID. " Time-out Pre-alert (Repeater/Ext-PTT) It can configure a timing to activate the TOT Pre-alert to notify a user that the transmission is going to be terminated. You can also configure the timing to sound the TOT Pre-alert tone. Configure a frequency by the spin buttons or directly enter the value. (Refer to " Time-out Timer (TOT) (Repeater/Ext-PTT).) Note: You cannot configure this duration when the “Time-out Timer” is configured to “Off”. " TOT Rekey Time (Repeater/Ext-PTT) It can configure the duration between the time that the transmission ends with the TOT and the time that the TKR-750/850/751/851 can start transmitting again. You can configure the duration by the spin buttons or directly enter the value. (Refer to " Time-out Timer (TOT) (Repeater/Ext-PTT).) Note: ! You can transmit immediately after the TOT expires when the TOT Rekey Time function is disabled. ! You cannot configure the duration if the “Time-out Timer” is configured to “Off”. " TOT Reset Time (Repeater/Ext-PTT) It can configure the duration between the time when the transmission ends before the TOT expires and the time that the counter of the TOT resets. Configure the duration by the spin buttons or directly enter the value. (Refer to " Time-out Timer (TOT) (Repeater/Ext- PTT).) Note: ! The TOT is reset immediately after the ends of transmission when the TOT Reset Time function is disabled. ! You cannot configure the duration if the “Time-out Timer” is configured as “Off”. " Repeat Hold Time It can configure the duration to keep transmitting even the receive signal is gone. It should be used to prevent a interruption due to repeat a weak signal. You can configure a duration by the spin buttons or directly enter the value. Note: ! The 750/850/751/851 returns to the reception mode when the repeater PTT is released when the Repeat Hold Time is disabled. Range Off, 0.5 - 30 min. In steps of 0.5 min. Default 5.0 min. Range Off, 1 - 10 sec. In steps of 1 sec. Default Off Range Off, 1 - 60 sec. In steps of 1 sec. Default Off Range Off, 1 - 15 sec. In steps of 1 sec. Default Off Range Off, 1 - 10 sec. In steps of 0.1 sec. Default Off

Field Programming Reference (FPRG)

28 6 EDIT MENU ! The duration configured in the Repeat Hold Time is handled as the TOT. ! The audio signal is muted while the Repeat Hold Time is counting down. " DQT Turn-off Code It can configure a duration to send a DQT Turn-off code. This function eliminates the squelch tail noise on the receiving side by sending the DQT Turn-off code when the transmitting party stop to transmit. You can configure it by the spin buttons or directly enter the value. Note: When the QT/DQT Encode configured to the channel is DQT, the DQT Turn-off code is sent. " QT Decode Delay It can configure a duration between the time when the time the received QT signalling un-matches and the time when the TKR-750/850/751/851 starts the QT Decode operation. With this function, the QT Reverse Burst code should not be recognized as a normal QT signalling. You can configure a time by the spin buttons or directly enter the value. (Refer to 6.2.12 QT Reverse Burst.) Note: The TKR-750/850/751/851 starts the QT Decode operation immediately after the received QT signalling un-matches if the QT Decode Delay is disabled. " Test Tone It can configure the frequency of single tone transmitted when Test Tone assigned to a PF key or an Auxiliary Input Port is enabled. You can configure a tone by the spin buttons or directly enter the value to configure the duration. (Refer to 6.5 Key Assignment Window, 6.10 Function Port Window.) Note: The TKR-750/850/751/851 sends the CW ID/Message only when sending the CW ID/Message while transmitting Test Tone. It does not modulate the repeat audio signal while transmitting Test Tone. (Refer to 6.3 CW ID Window, 6.12 CW Message Window.) " Squelch Level It can configure a squelch level used to eliminate the weak signal. It should decrease to listen to weak radio signals and increase the level for only strong radio signals communication. You can configure the level by the spin buttons or directly enter the value. Note: When using the channel that “Operation Mode” is configured as “Repeat” and the “QT/DQT Encode” is configured as “None”, the TKR-750/850/751/851 activates the repeat operation regardless of the presence of the reception signal if the Squelch Level is configured as “0”. (Refer to 6.2.4 QT/DQT Encode, 6.2.8 Operation Mode.) " QT Reverse Burst Time It can configure a duration to send the QT Reverse Burst code. This function eliminates the squelch tail noise on the receiving side by sending the QT Reverse Burst code at end of transmitting. You can configure a duration by the spin buttons or directly enter the value. (Refer to 6.2.12 QT Reverse Burst.) Note: ! This function is available only when the QT/DQT Decode code is enabled in the “Channel Edit” window. ! When the QT/DQT Encode code configured to the channel is QT, the TKR-750/850/751/851 sends the QT Reverse Burst Code. When the DQT Encode is selected, the it sends the QT Turn-off Code. " Backup Battery System It can configure a timing to emit the Backup Battery Warning Tone/Operation Tone. Select “Secondary Input Backup” or “Main Line Backup” from the dropdown list. (Refer to 6.4.2 Optional Features 2 Tab.) " Power Supply Lower Level It can configure a reference voltage in order to activate/deactivate the Power Supply Lower Limit. This function activates an Auxiliary output port that is assigned to the Power Supply Lower Limit when the Range 140 - 200 ms In steps of 1 ms Default 170 ms Range Off, 1 - 250 ms In steps of 1 ms Default 80 ms Range 300 - 3000 Hz In steps of 1 Hz Default 1000 Hz Range 0 (Shallow) - 15 (Tight) In steps of 1 Default 1 Range 140 - 200 ms In steps of 1 ms Default 160 ms Range Secondary Input Backup Emits the Backup Battery Warning Tone or the Operation Tone when the power is switched from the main power to the backup power. Main Line Backup Emits the Backup Battery Warning Tone or the Operation Tone when the voltage of the main power becomes lower than the Power Supply Lower Level. Default Secondary Input Backup

6 EDIT MENU

29 Field Programming Reference (FPRG) Version: 1.01 voltage of the power becomes lower than the configured level. You can configure the level by the spin buttons or directly enter the value. (Refer to 6.10 Function Port Window.) " RX Signal Detect (Below) It can configure the reference RSSI voltage level to activate/deactivate the Reception Signal that is assigned to an Auxiliary output port. This function activates it that is assigned to the RX Signal Detect when the RSSI voltage becomes lower than the configured level and the port deactivates when the voltage level becomes higher than the configured level. Configure the level by the spin buttons or directly enter the value. (Refer to 6.10 Function Port Window.) " External Monitor This function opens squelch when the Ext. Monitor terminal receives a signal. The signal is assigned to the pin 15 of the control interface jack (25-pin connector) located on the rear panel. Select “Squelch Off” or “Monitor” from the dropdown list. (Refer to FUNC 1 Basic Operation.) Note: ! The Ext. Monitor terminal is fixed to Active Low. ! Operates in the signalling squelch mode when the channel is configured to the decode signalling mode and performing the repeat operation even if the Ext. Monitor terminal is operating. " Fan Action It can configure how to control the cooling Fan. Select the fan to be always switched On or be switched On when the internal temperature increases and stop running when the temperature decreases. Select “Continuous” or “Temperature” from the dropdown list. Note: You cannot disable the operation of the fan. " Data Password It can configure a Data Password. With this function enabled, the configuration data of the TKR-750/850/ 751/851 will not be read even when an unauthorized person attempts to read it by FPU. Click “Data Password” to view the “Data Password” window, then configure the data password. Figure 6-9 Data Password window Enter the password a maximum of 6 digits in the “Data Password” edit box and type the same password in the “Confirmation” edit box to confirm it, then click “OK”. Note: The data password does not prevent the configuration data from being written since it only prevents the data from being read. " Off-hook Decode It can decode the received signalling when the local microphone is in the Off-hook position. Note: When this function is disabled and the local microphone is in off-hook position, the TKR-750/850/751/851 operates in the carrier squelch mode to mute or unmute Range 10.6 - 13.6 V In steps of 0.1 V Default 11.7 V Range -120 - -95 dBm In steps of 1 dBm Default -118 dBm Range Squelch Off Opens squelch when the Ext. Monitor terminal receives a signal. Monitor Allows to perform carrier squelch when the Ext. Monitor terminal receives a signal. Default Squelch Off Range Continuous The cooling Fan is always switched On. Temperature The cooling fan is switched On when the internal temperature increases. Default Continuous Range 6 digits Default Blank Range Checked Receives the QT/DQT signalling and opens squelch (signalling Squelch) regardless of the local microphone position. Unchecked Operates in the signalling squelch mode while the microphone is in on- hook position, and it receives a carrier and opens squelch (Carrier squelch) while the microphone is in off-hook position. Default Checked

Field Programming Reference (FPRG)

30 6 EDIT MENU the speaker. It operates in the signalling squelch mode when it makes the repeat operation. " Scrambler Backup It can restore the Voice Scrambler configuration. When this function is enabled, the On/Off status is backup even if you turn the TKR-751/851 OFF after Voice Scrambler is on. Note: ! You can use this function only when the optional Voice Scrambler Board is installed in it. ! Refer to the Modification Information when installing the optional Voice Scrambler Board in the TKR-750/850/751/ 851. " TX Standby on Frequency It can shift a transmission frequency when the TKR- 750/850/751/851 is in standby mode. (Refer to FUNC 13 TX Standby Frequency function.) " PTT Priority It can configure the priority of the repeater PTT, the external PTT, and the Local Mic PTT. When the selected PTT configuration has higher priority than the current PTT, the TKR-750/850/751/851 switches the signalling and the modulation signal line corresponding to the selected PTT configuration that has higher priority. Change the priority of the PTT by the spin buttons. (Refer to FUNC 6.7 PTT Priority.) " Firmware Program It can allow the TKR-750/850/751/851 enter in the Firmware Programming Mode. When this function is enabled, the it enters Firmware Programming Mode by pressing the PF1 key and the power switch on at the same time. Note: You must run the “FPRO.EXE” in order to write the Firmware program. Refer to the Service Manual for details. YOU MUST CONFIRM THAT THIS FUNCTION SHOULD BE DISABLED BEFORE SHIPPING TO THE END USER. OTHERWISE, IT MIGHT HAVE SOME TROUBLE TO REWRITE OR BROKEN IT ACCIDENTALLY. Range Checked The Voice Scrambler status is backup. Unchecked The Voice Scrambler status is canceled and return to the default. Default Unchecked Range Checked Wait a call with the transmission frequency configured to each channel. Unchecked Shifts the transmission frequency by -18.75 kHz and wait a call. Default Unchecked Default Priority 1: Local Mic PTT Priority 2: External PTT Priority 3: Repeater PTT Range Checked Allow to enters Firmware Programming Mode. Unchecked Not allow to enters Firmware Programming Mode Default Unchecked

6 EDIT MENU

31 Field Programming Reference (FPRG) Version: 1.01 6.4.2 Optional Features 2 Tab On this tab, it can configure the transmission operation by the Local Mic PTT and the tones. Figure 6-10 Optional Features 2 tab " Time-out Timer (TOT) (Local Mic PTT) This is a duration to make continuous transmission by the Local Mic PTT. The TKR-750/850/751/851 automatically stops transmission and returns to the reception mode when the TOT expires. Configure a duration by the spin buttons or directly enter the value. Note: The TOT function is not applicable to send the CW ID. " Time-out Pre-alert (Local Mic PTT) This is a timing to activate the TOT Pre-alert to notify the user that the transmission is going to be terminated to sound the TOT Pre-alert tone. Configure a timing by the spin buttons or directly enter the value. (Refer to " Time-out Timer (TOT) (Local Mic PTT).) Note: It not allow to configure this function when the “Time-out Timer” is configured as “Off”. " TOT Rekey Time (Local Mic PTT) This is a duration between the time that the transmission ends with the TOT and the time when it starts transmitting again. Configure the timing by the spin buttons or directly enter the value. (Refer to " Time-out Timer (TOT) (Local Mic PTT).) Note: ! It can transmit immediately after the TOT expires when the TOT Rekey Time is disabled. ! It not allows to configure the duration if the “Time-out Timer” is configured as “Off”. " TOT Reset Time (Local Mic PTT) This is a duration between the time when the transmission ends before the TOT expires and the time when the counter of the TOT resets. Configure the timing by the spin buttons or directly enter the value. (Refer to " Time-out Timer (TOT) (Local Mic PTT).) Note: ! The TOT is reset immediately after the end the transmission when the TOT Reset Time is disabled. ! It not allow to configure the duration if the “Time-out Timer” is configured as “Off”. " Busy Channel Lockout This is the Busy Channel Lockout function. If the Local Mic PTT is pressed while other groups are using that channel, it may interfere on-going communications. This function prevents you from such interference. Select “Off”, “Carrier”, or “QT/DQT” from the dropdown list. Note: You must release the PTT switch to transmit after BCL is activated even when the channel becomes free. " Tone Volume This is a volume level of “Power On Tone”, “Warning Alert Tone”, and “Control Tone”. Configure the volume level by the spin buttons and directly enter the value. Note: The Tone Volume configuration does not interlock with the VOLUME control. Range Off, 15 - 255 sec. In steps of 1 sec. Default 60 sec. Range Off, 1 - 10 sec. In steps of 1 sec. Default Off Range Off, 1 - 60 sec. In steps of 1 sec. Default Off Range Off, 1 - 15 sec. In steps of 1 sec. Default Off Range Carrier Restrict the transmission when the channel is Busy. QT/DQT Restrict the transmission when the channel has a carrier and the QT/DQT does not match. Off Always transmit. Default Off Range 0 - 31 In steps of 1 Default 3

Field Programming Reference (FPRG)

32 6 EDIT MENU " Power On Tone This allows to emits the Power On Tone when the TKR-750/850/751/851 is turned ON. " Warning Alert Tone This allows to emit the Warning Tone. (Refer to " Time-out Timer (TOT) (Local Mic PTT), " TOT Rekey Time (Local Mic PTT), " Busy Channel Lockout.) " Control Tone This allows to emit the Control Tone when a PF key is pressed. " Backup Battery Warning Tone This allows to emit the Backup Battery Warning Tone when the power is switched to the backup power. " Backup Battery Warning Tone Frequency This is a frequency of the Backup Battery Warning Tone. Configure the frequency by the spin buttons or directly enter the value. (Refer to " Backup Battery Warning Tone.) Note: You can configure the frequency of the Backup Battery Warning Tone only when the Backup Battery Warning Tone is enabled. " Backup Battery Warning Tone Send to RA This function allows to emit the Backup Battery Warning Tone from the front speaker (RA output). The dispatcher and operator can be aware it is operating with backup power. (Refer to " Backup Battery Warning Tone.) Note: You can configure this function only when the Backup Battery Warning Tone is enabled. " Backup Battery Operation Tone This is a tone sounded during transmitting by the Repeater PTT, the External PTT, or the Local Mic PTT with the backup battery. " Backup Battery Operation Tone Frequency This is a frequency of the Backup Battery Operation Tone. Configure a frequency by the spin buttons or Range Checked The Power On Tone sounds. Unchecked The Power On Tone does not sound. Default Checked Range Checked There are three Warning Tones. • Warning Alert Tone This tone sounds when pressing the PTT switch even after the Time-out Timer of the Local Mic PTT expires or while the Rekey Time is activated. • TOT Pre-alert Tone This tone sounds when the Time- out Timer is about to expire. • TOT Pre-alert Tone This tone sounds when the transmission is disabled while the Busy Channel Lockout function is enabled. Unchecked Not emit the Warning Alert Tone. Default Checked Range Checked There are four Control Tones. • Key Press Tone (A) This tone sounds when the assigned function is enabled by pressing the PF key. • Key Press Tone (B) This tone sounds when the assigned function is disabled by pressing the PF key. • Key Input Error Tone This tone sounds when the operation of the PF key is denied. • Roll Over Tone This tone sounds when selecting the last channel by the PF key. Unchecked Not emit the Control Tone. Default Checked Range Checked Emits the Backup Battery Warning Tone for 5 seconds when the power is switched to the backup battery. Unchecked Not emit the Backup Battery Warning Tone even when the power is switched to the backup battery. Default Unchecked Range 300 - 3000 Hz In steps of 10 Hz Default 1630 Hz Range Checked Emits the Backup Battery Warning Tone from the front speaker and send to RA. Unchecked Not emit the Backup Battery Warning Tone. Default Unchecked Range Checked Emits the Backup Battery Operation Tone. Unchecked Not emit the Backup Battery Operation Tone. Default Unchecked

6 EDIT MENU

33 Field Programming Reference (FPRG) Version: 1.01 directly enter the value. (Refer to " Backup Battery Operation Tone.) Note: You can configure this function only when the Backup Battery Operation Tone is enabled. " Backup Battery Operation Tone Interval This is a interval time to sound the Backup Battery Operation Tone. Configure the interval by the spin buttons or directly enter the value to configure the interval. (Refer to " Backup Battery Operation Tone.) Note: You can configure this function only when the Backup Battery Operation Tone is enabled. " Backup Battery Operation Tone Send to RA This allows to emit the Backup Battery Operation Tone from the front speaker and send to RA. (Refer to " Backup Battery Operation Tone.) Note: You can configure this function only when the Backup Battery Operation Tone is enabled. " Courtesy Tone This allows to emit a courtesy tone when finishing the transmission using the repeater PTT, the external PTT, or the Local Mic PTT. Note: You can configure this tone only when the DTMF signalling is used. " Courtesy Tone Frequency This is a frequency of the courtesy tone. Configure the frequency by the spin buttons or directly enter the value to configure the frequency. (Refer to " Courtesy Tone.) Note: ! You can configure this tone only when the DTMF signalling is used. ! You can configure this tone only when the Courtesy Tone is enabled. " Courtesy Tone Period This is a period of the Courtesy Tone. Configure the period by the spin buttons or directly enter the value to configure the period. (Refer to " Courtesy Tone.) Note: ! You can configure this period only when the DTMF signalling is used. ! You can configure this tone only when the Courtesy Tone is enabled. " Courtesy Tone Send to RA This allows to emit the Courtesy Tone from the front speaker and send to RA. (Refer to " Courtesy Tone.) Note: ! You can configure this period only when the DTMF signalling is used. ! You can configure this tone only when the Courtesy Tone is enabled. Range 300 - 3000 Hz In steps of 10 Hz Default 600 Hz Range 5 - 900 sec. In steps of 5 sec. Default 5 sec. Range Checked Emits the Backup Battery Operation Tone from the front speaker and send to RA. Unchecked Not emit the Backup Battery Warning Tone fro speaker and not send to RA. Default Unchecked Range Checked Emits the Courtesy Tone. Unchecked Not emit the Courtesy Tone. Default Unchecked Range 300 - 3000 Hz In steps of 10 Hz Default 800 Hz Range Off, 100 - 1000 ms In steps of 10 ms Default 100 ms Range Checked Emits the Courtesy Tone from the front speaker and send to RA. Unchecked Not emit the Courtesy Tone from the front speaker and not send to RA. Default Unchecked

Field Programming Reference (FPRG)

34 6 EDIT MENU 6.4.3 Others Tab (Optional Features) On this tab, you can activate/deactivate Power Saver Mode and switch the power source, and configure the functions activating when the TKR-750/850/751/851 is turned ON. You can configure the Save On/Off, the Start Up operation, the “Backup Power Function”, and the “Main Power Function”. Figure 6-11 Others tab Table 6-2 Available functions Function Name Description None The TKR-750/850/751/851 does not perform any operation. AUX Out 1 Off - AUX Out 5 Off The function assigned to the specified Auxiliary Output port is disabled when the TKR-750/850/751/851 starts operation. You can assign this function when “Selectable” is configure to the Auxiliary Output ports 1 - 5. (Refer to Table 6-7 Assigning Functions to the Auxiliary Output Ports.) AUX I/O 1 Off - AUX I/O 6 Off The function assigned to the specified Auxiliary I/O port is disabled when the TKR-750/850/751/851 starts operation. You can assign the function when “Selectable” is configured to the Auxiliary I/O ports 1 - 6. (Refer to Table 6-7 Assigning Functions to the Auxiliary Output Ports.) AUX Out 1 On - AUX Out 5 On The function assigned to the specified Auxiliary Output port is enabled when the TKR-750/850/751/851 starts operation. You can assign this function when “Selectable” is configure to the Auxiliary Output ports 1 - 5. (Refer to Table 6-7 Assigning Functions to the Auxiliary Output Ports.) AUX I/O 1 On - AUX I/O 6 On The function assigned to the specified Auxiliary I/O port is enabled when the TKR-750/850/751/851 starts operation. You can assign the function when “Selectable” is configured to the Auxiliary I/O ports 1 - 6. (Refer to Table 6-7 Assigning Functions to the Auxiliary Output Ports.) Channel 1 - Channel 16 The TKR-750/850/751/851 moves to the channel selected from CH 1 to CH 16. You cannot configure this function when “Channel Select” is configured to Auxiliary I/O ports 1 - 4. “E2” appears on the display when specifying the channel without data. (Refer to Table 6-7 Assigning Functions to the Auxiliary Output Ports.) Channel Down The TKR-750/850/751/851 moves to the next lower channel. The channel without data is skipped. Channel Up The TKR-750/850/751/851 moves to the next higher channel. The channel without data is skipped. CW ID On The TKR-750/850/751/851 sends the CW ID when it starts operation. (Refer to 6.3 CW ID Window.) This function is available on the channel having the CW ID. CW Message 1 - CW Message 8 The TKR-750/850/751/851 sends the assigned CW ID from CW Messages 1 to 8 when it starts operation. (Refer to 6.12 CW Message Window.) DC Power Save Off The TKR-750/850/751/851 exits Power Saver Mode when it starts operation. You cannot configure this function to the Save On/Off function. DC Power Save On The TKR-750/850/751/851 enters Power Saver Mode when it starts operation. You cannot configure this function to the Save On/Off function. Display Off All LEDs other than the Power SW LED that is located on the front panel unlit. This function can be enabled only when the TKR-750/850/751/851 is in Power Saver Mode. Display On All LEDs on the front panel light. This function can be enabled only when the TKR-750/850/751/851 is in Power Saver Mode. Hold Time Disable The TKR-750/850/751/851 disables the Repeat Hold Time. You can configure this function only when at least one channel is configured as the Repeat for Operation mode and the Repeat Hold Time is enabled. (Refer to 6.4.1 Optional Features 1 Tab.)

6 EDIT MENU

35 Field Programming Reference (FPRG) Version: 1.01 Hold Time Enable The TKR-750/850/751/851 enables the Repeat Hold Time. You can configure this function only when at least one channel is configured as the Repeat for Operation mode and the Repeat Hold Time is enabled. (Refer to 6.4.1 Optional Features 1 Tab.) Local TX Disable The TKR-750/850/751/851 restricts the transmissions using the Local Mic PTT. Local TX Enable The TKR-750/850/751/851 enables the transmissions using the Local Mic PTT. Low Power Off*1 The TKR-750/850/751/851 switches the transmission power from Low to High. This function is enabled only when at least one channel is configured as High for TX Power. (Refer to 6.2.11 TX High Power.) Low Power On *1 The TKR-750/850/751/851 switches the transmission power from High to Low. This function activates only when at least one channel is configured as High for TX Power. (Refer to 6.2.11 TX High Power.) Monitor Off The TKR-750/850/751/851 enables the signalling Decode function. This function does not operate when the TKR-750/850/751/851 enables the repeat operation. Monitor On The TKR-750/850/751/851 disables the signalling Decode function. Multi-table Sub The signalling specified in the Multi-table Select is switched to the Sub-table. (Refer to 6.10.1 AUX Select Tab.) Multi-table Main The signalling specified in the Multi-table Select is switched to the Main-table. (Refer to 6.10.1 AUX Select Tab.) QT/DQT Decode Disable The TKR-750/850/751/851 disables QT/DQT Decode function. This function is available even when it is performing the repeat operation. QT/DQT Decode Enable The TKR-750/850/751/851 enables the QT/DQT Decode function. QT/DQT Encode Disable The TKR-750/850/751/851 disables the QT/DQT Encode function. QT/DQT Encode Enable The TKR-750/850/751/851 enables the QT/DQT Encode function. Repeat Disable The TKR-750/850/751/851 disables the repeat operation. You cannot configure this function if no channel is configured to the repeat operation. Repeat Enable The TKR-750/850/751/851 enables the repeat operation. You cannot configure this function if no channel is configured to the repeat operation. Scan Off The TKR-750/850/751/851 disables the scan function. Scan On The TKR-750/850/751/851 enables the scan function. Scrambler Off The TKR-750/850/751/851 disables Scrambler. You cannot configure this function when the optional Scrambler board is not installed. Scrambler On The TKR-750/850/751/851 enables Scrambler. You cannot configure this function when the optional Scrambler board is not installed. Squelch Off The TKR-750/850/751/851 disables Squelch. Squelch On The TKR-750/850/751/851 enables Squelch. Test Tone Off The TKR-750/850/751/851 switches Test Tone Off. Test Tone On The TKR-750/850/751/851 switches Test Tone On. TOT Disable*2 The TKR-750/850/751/851 disables Time-out Timer function. TOT Enable*2 The TKR-750/850/751/851 enables Time-out Timer function. TX Disable The TKR-750/850/751/851 restricts all transmissions. TX Enable The TKR-750/850/751/851 permits all transmissions. *1: You cannot switch to Low Power while transmitting or scanning. The Low Power status is retained even if the channel is changed or the TKR-750/850/751/851 is turned ON/OFF. *2: This function can be used for the TOT of the Local Mic PTT and the Repeater/External PTT. Function Name Description

Field Programming Reference (FPRG)

36 6 EDIT MENU " Save Delay Timer A This is a duration between the time when an Auxiliary Input port or an PF key assigned to the Display On function receives a signal and the time when the LED is switched Off or the AF Amp is switched Off while the TKR-750/850/751/851 is in Power Saver Mode. Configure the duration by the spin buttons or directly enter the value to configure the duration. (Refer to 6.5 Key Assignment Window.) (Refer to Table 6.10 Function Port Window.) Note: The Power LED does not unlit even if the Display On function is activated. " Save Delay Timer B This is a duration between the time when the TKR-750/ 850/751/851 enters Power Saver Mode and the time when the Power Saver function is switched On (Display Off). You can also configure the duration from the time when the TKR-750/850/751/851 switches from Busy status to Not Busy status to the time when it enters Save On status. Configure the durations by the spin buttons or directly enter the value to configure the durations. " Save Mode Duration This is a duration between the time when the TKR-750/ 850/751/851 enters Power Saver Mode and the time when it automatically exits the Mode. Configure the duration by the spin buttons or directly enter the value to configure the duration. " Save On Function It can configure the function to activate when the TKR- 750/850/751/851 enters Power Saver Mode. You can assign three functions and they operate in order of 1st, 2nd, then 3rd. Select the function from the dropdown list. " Save Off Function It can configure the function to activate when the TKR- 750/850/751/851 exits Power Saver Mode. You can assign three functions and they operate in order of 1st, 2nd, then 3rd. Select the functions from the dropdown list. " Start Up It can configure the function to activate when the KR- 750/850/751/851 is turned ON. You can assign three functions and they operate in order of 1st, 2nd, then 3rd. Select the functions from the dropdown list. " Backup Power Function It can configure the function to operate when the power of the KR-750/850/751/851 is switched from the main power to the backup power. You can configure three functions and they operate in order of 1st, 2nd, then 3rd. Select the functions from the dropdown list. " Main Power Function It can configure the function to operate when the power of the KR-750/850/751/851 is switched from the backup power to the main power. You can configure three functions and they operate in order of 1st, 2nd, then 3rd. Select the functions from the dropdown list. Range 1 - 255 sec. In steps of 1 sec. Default 10 sec. Range 10 - 480 min. In steps of 10 min. Default 240 min. Range Off, 0.5 - 24 h In steps of 0.5 h Default Off Range Refer to Table 6-2 Available functions. Default None Range Refer to Table 6-2 Available functions. Default None Range Refer to Table 6-2 Available functions. Default None Range Refer to Table 6-2 Available functions. Default None Range Refer to Table 6-2 Available functions. Default None

6 EDIT MENU

37 Field Programming Reference (FPRG) Version: 1.01 6.5 Key Assignment Window You can assign functions to each PF key on the “Key Assignment” window. Figure 6-12 Key Assignment window Select the function to assign to the PF key. Note: The PF key of the front panel displayed on the “Key Assignment” window lights red when the PF key is selected. When the Channel Up function is assigned to the PF1 key, the PF1 key is referred to as “PF [Channel Up] key”. Table 6-3 Assigning functions to the PF Keys Range Refer to Table 6-3 Assigning functions to the PF Keys. Default PF1 Key: None PF2 Key: Repeat Disable/Enable PF3 Key: TX Disable/Enable PF4 Key: Take Over On/Off PF5 Key: Monitor On/Off PF6 Key: Channel Up Function Name Description None The TKR-750/850/751/851 does not perform any operation. AUX Out 1 On/Off - AUX Out 5 On/Off It can enable/disable the function assigned to the Auxiliary output port by pressing one of the PF keys. You can assign this function when “Selectable” is configure to the Auxiliary Output 1 to Auxiliary Output 5 ports. (Refer to Table 6-7 Assigning Functions to the Auxiliary Output Ports.) AUX I/O 1 On/Off - AUX I/O 6 On/Off It can enable/disable the function assigned to the Auxiliary I/O port by pressing one of the PF keys. You can assign the function when “Selectable” is configured to the Auxiliary I/O 1 to Auxiliary I/O 6 ports. (Refer to Table 6-7 Assigning Functions to the Auxiliary Output Ports.) Channel 1 - Channel 16 The TKR-750/850/751/851 moves to the channel from one of CH 1 to CH 16 channels. You cannot configure this function when “Channel Select” is configured to Auxiliary I/O ports 1 - 4. “E2” appears on the display when specifying the channel without data. (Refer to 6.10.1 AUX Select Tab.) Channel Down The TKR-750/850/751/851 moves to the next lower channel. The channel without data is skipped. Channel Up The TKR-750/850/751/851 moves to the next higher channel. The channel without data is skipped. CW ID On The TKR-750/850/751/851 sends the CW ID. (Refer to 6.3 CW ID Window.) This function is available on the channel having the CW ID. CW Message 1 - CW Message 8 The TKR-750/850/751/851 sends one of CW Message 1 to CW Message 8. (Refer to 6.12 CW Message Window.) DC Power Save On/Off It can enable/disable Power Saver Mode. (Refer to 6.4.3 Others Tab (Optional Features).) Display On/Off It can switch the panel LED On/Off. This function is enabled only when the TKR-750/850/751/851 is in Power Saver Mode. Hold Time Disable/ Enable It can disable/enable the Repeat Hold Time. You can configure this function only when at least one channel is configured as the Repeat for Operation mode and the Repeat Hold Time is enabled. (Refer to 6.4.1 Optional Features 1 Tab.) Local TX Disable/Enable It can disable/enable the transmissions by the Local Mic PTT. Low Power On/Off It can switch High or Low for the transmission power. This function activates only when at least one channel is configured as High for TX Power. (Refer to 6.2.11 TX High Power.) Monitor On/Off It can disable/enable the signalling Decode function. Monitor Momentary The TKR-750/850/751/851 activates the Monitor function while pressing the PF key.

Field Programming Reference (FPRG)

38 6 EDIT MENU Note: The level detection for the auxiliary input port is performed even if the PF key is pressed during the detection when the Auxiliary input port is active. In this case, the Key Input Error Tone sounds and the function assigned to the PF key does not operate. (Refer to FUNC 9 Tone, Refer to Table 6.10.2 AUX Tab. ) Multi-table Main/Sub It can toggle between Main and Sub for the signalling specified by the Multi-table Select by pressing the PF key. (Refer to 6.10.1 AUX Select Tab.) QT/DQT Decode Disable/Enable It can disable/enable QT/DQT Decode function by pressing the PF key. QT/DQT Encode Disable/Enable It can disable/enable QT/DQT Encode function by pressing the PF key. Repeat Disable/Enable It can disable/enable the repeat operation by pressing the PF key. It does not allow to configure this function if no channel is configured to the repeat operation. Reset The operation of the TKR-750/850/751/851 is reset and it returns to the default when pressing the PF key. Scan On/Off It can enable/disable the Scan function by pressing the PF [Scan On/Off] key. Scrambler On/Off It can enable/disable Scrambler by pressing the PF [Scrambler On/Off] key. Squelch On/Off It can disable/enable Squelch by pressing the PF [Squelch On/Off] key. Squelch Momentary It can disable Squelch while pressing the PF [Squelch Momentary] key. Take Over On/Off *1 It can enable/disable the control from an external device by pressing the PF [Take Over On/Off] key. Test Tone On/Off It can enable/disable Test Tone function by pressing the PF [Test Tone On/Off] key. TOT Disable/Enable It can enable/disable Time-out Timer by pressing the PF [TOT Disable/Enable] key. TX Disable/Enable It can restrict/permit all transmissions by pressing the PF [TX Disable/Enable] key. *1: When the control from the external device is enabled by pressing the PF [Take Over On/Off] key, you cannot control the external Monitor, the external PTT, the Auxiliary Input port, and the Auxiliary I/O (In) port. However, the Auxiliary Out port and the Auxiliary I/O (Out) port works. Function Name Description

6 EDIT MENU

39 Field Programming Reference (FPRG) Version: 1.01 6.6 Scan Information Window It can configure the Scan operation and conditions on the “Scan Information” window. (Refer to FUNC 16 Scan.) Figure 6-13 Scan Information window 6.6.1 Priority This is a priority channel type to be scanned periodically. You can select the mode from None, Fixed, and Selected from the dropdown list. TKR-750/850/751/851 scans channels in numerical order (Normal Scan) when the priority scan function is selected None. Note: ! You cannot configure the Priority Channel, Look Back Time A, and Look Back Time B when priority is configured as “None”. ! You cannot configure the Priority Channel when priority is configured as “Selected”. 6.6.2 Priority Channel This is a channel to be scanned periodically when TKR- 750/850/751/851 is scanning. Select the channel configured as the Priority Channel from the dropdown list or directly enter the channel number. Note: ! You cannot configure this function if the “Priority” is configured to “None” or “Selected”. ! The dropdown list only displays the channel having the configuration data. 6.6.3 Look Back Time A This is a interval time to check the priority channel when the scan is stopping on the normal channel and no signal is on the priority channel. Configure the period by the spin buttons or directly enter the value to configure the period. Note: It pauses on the Priority Channel when there is a signal to receive and the signalling matches while scanning the Priority Channel. 6.6.4 Look Back Time B This is a interval time to check the priority channel when the scan is stopping and a signal without same signalling is on the priority channel. Configure the period by the spin buttons or directly enter the value to configure the period. Note: It pauses on the Priority Channel when there is a signal to receive and the signalling matches while scanning the Priority Channel. 6.6.5 Revert Channel This is a condition of channel to transmit during scanning. Select the condition from the dropdown list. Range None Not perform the Priority Scan. Fixed The channels configured as the priority channel are scanned periodically. Selected The selected channel is configured as the priority channel when changing the channel. Default None Range 1 - 16 Default None Range 0.5 - 5.0 sec. In steps of 0.1 sec. Default 0.5 sec. Range 0.5 - 5.0 sec. In steps of 0.1 sec. Default 2.0 sec. Range Last Called Last Used Selected Selected + Talkback Priority Priority + Talkback Default Last Called

Field Programming Reference (FPRG)

40 6 EDIT MENU Table 6-4 Revert Channel Configuration Note: You are able to configure the channel used for the repeat operation as a Priority Channel. (Refer to 6.6.2 Priority Channel.) Although TKR-750/850/751/851 performs the repeat operation on the Priority Channel when receiving a call on the Priority Channel, it transmits with the channel matching the conditions configured in the Revert Channel function when receiving the transmission request having higher priority than the transmission with the repeater PTT. 6.6.6 Dropout Delay Time This is a duration time that TKR-750/850/751/851 automatically resumes the Scan after the receiving signal is disappear. Configure the duration by the spin buttons or directly enter the value to configure the duration. TKR-750/850/751/851 to resume scanning with the following conditions. • There is no signal to receive. • The received QT/DQT code becomes un-match. 6.6.7 Dwell Time This is a duration to resume scanning after stop transmitting. TKR-750/850/751/851 pauses scanning if the PTT switch is pressed to transmit during the scan and resumes scanning after the transmission ends. Configure the duration by the spin buttons or directly enter the value to configure the duration. 6.6.8 Off-hook Scan It can enable/disable the Off-hook Scan. TKR-750/850/ 751/851 activates the Scan function regardless of the local microphone position when this function is enabled. Note: TKR-750/850/751/851 continues scanning without pausing on the revert channel when receiving the transmission command with the TX Disable function. When the Off-hook Scan function is disabled, it moves to the revert channel. (Refer to 6.10 Function Port Window.) Function Description Last Called The revert channel is assigned to the last channel that is received signal and stopped scanning during scanning and transmit on it. In case of pausing the scan due to changing channel by PF key, it transmits on that channel. During pausing scan due to receiving signal, It is assigned as the revert channel, and transmits on it. Last Used The revert channel is assigned to the last channel that is transmitted during scanning. In case of pausing the scan due to changing channel by PF key, it transmits on that channel. While receiving a signal, It transmits on the revert channel. Selected The revert channel is assigned to the last selected channel. In case of pausing the scan due to changing channel by PF key, it is assigned as the revert channel and transmit on it. While receiving a signal, it changes to the revert channel and transmit. Selected + Talk Back The revert channel is assigned to the last selected channel and transmit on it during scan. In case of pausing scan due to changing channel by PF key, it transmits on that channel. While receiving a signal, It transmits on the current channel. Priority The revert channel is assigned to the priority channel and transmit on it during scan. Even when pausing scan due to selecting channel by PF key or receiving a signal during scan, it transmits on the priority channel. Priority + Talk Back The revert channel is assigned to the priority channel and transmit on it during scan. In case of pausing scan due to changing channel by PF key, it transmits on that channel. While receiving a signal, It transmits on the current channel. Range 0.5 - 5.0 sec. In steps of 0.5 sec. Default 3.0 sec. Range 0.5 - 5.0 sec. In steps of 0.5 sec. Default 3.0 sec. Range Checked Scanning regardless of the local microphone position. Unchecked Scanning only when the local microphone is in On-hook position. Default Checked

6 EDIT MENU

41 Field Programming Reference (FPRG) Version: 1.01 6.7 DTMF Window It can configure the DTMF encode condition. Figure 6-14 DTMF window 6.7.1 DTMF Speed This is a speed to send DTMF code. Select the speed from the dropdown list. 6.7.2 First Digit Delay Time This is a delay time between the time when TKR-750/850/ 751/851 starts transmitting and the time when it sends the DTMF code. Configure the duration by the spin buttons or directly enter the value to configure the duration. 6.7.3 First Digit Time This is a duration time to transmit the first digit of the DTMF code. Select the duration from the dropdown list. This function ensures the recognition of the first digit of the DTMF code detection for the receiving transceiver using the Power Saver or Scan functions. The duration of the first digit of the DTMF is obtained by adding the transmission time configured in the DTMF Speed and the First Digit Time. (Refer to 6.7.1 DTMF Speed.) 6.7.4 * and # Digit Time This is a duration time to transmit the “*” tone and the “#” tone of the DTMF code. Select the delay time from the dropdown list. In some case, these tone is used for special function, such as Connecting tone and Disconnecting tone. To extend these tone transmitting time, it allows to receive them correctly. The time of the “*” tone and the “#” tone is obtained by adding the transmission time configuring the DTMF Speed to the “*” and “#” Digit Time. (Refer to 6.7.1 DTMF Speed.) Note: When the first digit of the DTMF code is “*” tone or “#” tone, TKR-750/850/751/851 compares the duration time to transmit the first digit configured in the First Digit Time with the “*”and “# “Digit Time and uses the longer delay time to transmit. (Refer to 6.7.3 First Digit Time.) Range 6, 8, 10, 15 digit/s Default 6 digit/s Range 100 - 1000 ms In steps of 50 ms Default 100 ms Range 0, 100, 500, 1000 ms Default 0 ms Range 0, 100, 500, 1000 ms Default 0 ms

Field Programming Reference (FPRG)

42 6 EDIT MENU 6.8 “Encode/Decode Table” Window It can configure the DTMF Encode/Decode code and the function relating to the Transpond function. You can configure this function when the DTMF signalling is used. This window consists of “Encode” and “Decode” tabs and you can switch the window by clicking the tabs. Figure 6-15 Encode tab Figure 6-16 Decode tab 6.8.1 Encode Code It can configure the Encode code with a maximum of 16 digits of the DTMF Tone. Enter the code in the edit boxes from No. 1 to No. 32. 6.8.2 Frequency This is a frequency to transmit Single tone as the Transpond code when the function assigned to the PF key or the auxiliary port activates/deactivates. You can configure the frequency for both of “Activation” and “Deactivation”. Configure the frequency by the spin buttons or directly enter the value to configure the frequency. 6.8.3 Period This is a period to transmit Single Tone as the Transpond code when the function assigned to a PF key or an Auxiliary port activates/deactivates. You can configure the transmission period for both of “Activation” and “Deactivation”. Configure the period by the spin buttons or directly enter the value to configure the period. 6.8.4 Sidetone It allows to transmit a sidetone when sending the DTMF code. This function is used to feedback the audio tone to the transceiver's speaker. Note: You cannot transmit the sidetone when the “Operation Mode” is configured as “Simplex”. (Refer to 6.2.8 Operation Mode.) 6.8.5 Decode Code Range 16 digits 0 - 9, A - D, *, # Default No. 1 is 159D. No. 2 - No. 32 are blank. Range 100 - 3000 Hz In steps of 10 Hz Default 800 Hz (Activation) 600 Hz (Deactivation) Range 100 - 3000 ms In steps of 50 ms Default 1000 ms (Activation) 2000 ms (Deactivation) Range Checked Transmits the sidetone with DTMF code. Unchecked Not transmit the sidetone with the DTMF code. Default Checked

6 EDIT MENU

43 Field Programming Reference (FPRG) Version: 1.01 It can configure the Decode code with a maximum of 16- digit DTMF Tone. Enter the code in the edit boxes from No. 1 to No. 40. Note: If the same DTMF code is configured in the different table, it may use the same DTMF code to decode for the Air Remote function. In this case, the function may not work properly. (Refer to 6.9 Remote Control Window.) 6.9 Remote Control Window It can configure the TKR-750/850/751/851 to be controlled by other transceivers on the “Remote Control” window. It is possible to control functions assigned to the PF key or the Auxiliary Port by the Air Remote code. Air Remote activates the function configured previously (Channel Up function and Scan On/Off function, etc.) when the received code is same as the transmitted code from other transceivers. The code used in this function is referred to as the “Air Remote code”. This window consists of PF key and AUX Input/Output tabs and you can switch the window by clicking the tabs. " Conditions od the Air Remote # When the Air Remote functions for the Auxiliary Input (Level) and the PF key are assigned to the same, the status of the Auxiliary Input (Level) port gets the preference over the operation of the PF key. In this case, the Transpond code is not sent and the Air Remote function is canceled. For example, when the scan function is assigned to the Auxiliary Input (Level) port and activating, the PF keys relating to the Scan operation and the Air Remote function are not acceptable. # It can select a timing to send a Transpond code from “Before”, “After” or “Both” the received Air Remote code is processed. Before: TKR-750/850/751/851sends the Transpond code as soon as it receives the Air Remote code. The Transpond code is not sent when the transmission is restricted. After: TKR-750/850/751/851 sends the Transpond code after processing the function related received Air Remote code. The Transpond code is not sent when the transmission is restricted. Also it is not sent when that function cannot be processed. This operation is the same as when the function is disabled corresponding to the status of TKR-750/ 850/751/851 even when the PF key is pressed. Both: TKR-750/850/751/851 sends the Transpond code when receiving the Air Remote code and after processing the received code. The Transpond code is not sent when the transmission is restricted. # TKR-750/850/751/851 uses the following channel to send the code during Scan. (Refer to 6.6.5 Revert Channel.) Range 16 digits 0 - 9, A - D, *, # Default No. 1 is 159D. No. 2 - No. 40 are blank.

Field Programming Reference (FPRG)

44 6 EDIT MENU Table 6-5 The Transmitting channel during Scan. Note: ! The Transpond code is sent while the scan operation is pausing. ! The Transpond code is sent on the Revert CH when the Scan operation is switched On by the Air Remote. 6.9.1 PF Key Tab On this tab, It can configure the Air Remote code assigned to PF keys controlled. Figure 6-17 “PF Key” tab " Function (PF Key) The function configured on the “Key Assignment” window appears. However, you cannot change the configuration on this window. (Refer to 6.5 Key Assignment Window.) " Activation (PF Key) This is a standby Air Remote code to be decoded in order to activate the assigned function for the PF key. From the dropdown list, you can select a table number in the “Decode” tab from “Encode/Decode” table window. (Refer to 6.8 “Encode/Decode Table” Window.) Note: ! You cannot configure the “Activation” if no function is assign to “Function”. (Refer to " Function (PF Key).) ! When Dec. Table is already used in other functions, you cannot configure the same Dec. Table. " Deactivation (PF Key) This is a standby Air Remote code to be decoded in order to deactivate the assigned function for the PF key. From the dropdown list, you can select a table number in the “Decode” tab from “Encode/Decode” table window. (Refer to 6.8 “Encode/Decode Table” Window.) Note: ! You cannot configure “Deactivation” if no function is assign to “Function”. (Refer to " Function (PF Key).) ! You cannot configure “Deactivation” to the functions that it cannot be disable, such as Channel Up function. ! When Dec. Table is already used to other functions, you cannot configure the same Dec. Table. " Transponder (PF Key) This is a timing to send the Transpond code. Select one of “None”, “Fore”, “After” and “Both” from the dropdown list. Note: ! You cannot configure “Transponder” if no function is assign to “Function”. (Refer to " Function (PF Key).) ! You may not be allowed to select “After” or “Both” due to the assigned functions to the PF key. (Example: Reset, CW ID On) (Refer to 6.5 Key Assignment Window.) Transmission event During the Scan While the Scan pauses. AUX In & In (I/O) Revert CH Revert CH AUX Out Revert CH CH that Scan pauses Air Remote Transpond - CH that Scan pauses Range None, Dec. Table 1 - 40 Default None Range None, Dec. Table 1 - 40 Default None Range None Not send the Transpond code. Fore Sends the Transpond code when receiving the Air Remote code. After Sends the Transpond code after processing the received Air Remote code. Both Sends the Transpond code when receiving the Air Remote code and after processing the received code. Default None

6 EDIT MENU

45 Field Programming Reference (FPRG) Version: 1.01 " Activation (PF Key Transponder) This is a Transpond code that is sent when the function assigned to AUX In/Out activates with the Air Remote function and “Transponder” is configured as “Yes”. (Refer to " Transponder (PF Key).) From the dropdown list, you can select a table number in the “Decode” tab from “Encode/Decode” table window. (Refer to 6.8 “Encode/Decode Table” Window.) Note: You can use Single Tone as the Transpond code when the DTMF signalling is configured. (Refer to " Single Tone (PF Key Transponder).) " Deactivation (PF Key Transponder) This is a Transpond code when the function assigned to Aux In/Out deactivates with the Air Remote function and “Transponder” is configured as “Yes”. (Refer to " Transponder (PF Key).) From the dropdown list, you can select a table number in the “Decode” tab from “Encode/ Decode” table window. (Refer to 6.8 “Encode/Decode Table” Window.) Note: You can use Single Tone as the Transpond code when the DTMF signalling is configured. (Refer to " Single Tone (PF Key Transponder).) " Single Tone (PF Key Transponder) It can use a Single Tone for the Transpond code. You can configure this function only when the DTMF signalling is used. Note: You cannot individually select Single Tone for Aux Transponder Activation and Deactivation. 6.9.2 AUX Input/Output Tab On this tab, it can control the function assigned to the Auxiliary Port by the Air Remote code. Figure 6-18 AUX Input/Output tab " Function (AUX Input) The function assigned on the “Aux Input” tab of the “Function Port” window appears. However, you cannot change the configuration in this window. (Refer to 6.10.2 AUX Tab.) Although you can configure three functions (1st, 2nd, and 3rd) to the Auxiliary Input port, it is possible activate only the function configured to the 1st with the Air Remote function. (Refer to 6.10 Function Port Window.) " Activation (AUX Input) this is a standby Air Remote code to be decoded in order to activate the assigned function for the Auxiliary Input port. From the dropdown list, you can select a table number on the “Decode” tab from “Encode/ Decode” table window. (Refer to 6.8 “Encode/Decode Table” Window.) When no function is assigned to “Function” (None), It can perform the encode function by interlocking with the sensor input of the external device. From the dropdown list, you can select a table number on the “Decode” tab from “Encode/ Decode” table window. (Refer to 6.8 “Encode/Decode Table” Window.) Note: When Dec. Table is already used for the other function, it does not allow to configure the same Dec. Table. Range None, Enc. Table 1 - 32 Default None Range None, Enc Table 1 - 32 Default None Range Checked Uses Single Tone for the Transpond code. Unchecked Not use Single Tone for the Transpond code. Default Unchecked Range None, Dec. Table 1 - 40, Enc Table 1 - 32 Default None

Field Programming Reference (FPRG)

46 6 EDIT MENU " Deactivation (AUX Input) This is a standby Air Remote code to be decoded in order to deavtivate the assigned function for the Auxiliary Input port. From the dropdown list, you can select a table number on the “Decode” tab from “Encode/ Decode” table window. (Refer to 6.8 “Encode/Decode Table” Window.) When no function is assigned to “Function”, you can perform the encode function by interlocking with the sensor input of the external device. You can select the table number configured with the “Encode” tab on the “Encode/Decode Table” window from the dropdown list. (Refer to 6.8 “Encode/Decode Table” Window.) Note: ! You cannot configure “Deactivation“to the functions that you cannot disable, such as the Channel Up function. ! When Dec. Table is already used to the other function, you cannot configure the same Dec. Table. " Transponder (AUX Input) This is a timing to send the Transpond code. Select one of “None”, “Fore”, “After” and “Both” from the dropdown list. Note: ! You cannot configure “Transponder” if no function is assign to “Function”. (Refer to " Function (AUX Input).) ! You may not be allowed to select “After” or “Both” due to the assigned functions to the Auxiliary Input port. (Example: Reset, CW ID On) (Refer to 6.5 Key Assignment Window.) " Function (AUX Output) The function assigned on the “Aux Output” tab of the “Function Port” window appears. However, you cannot change the configuration in this window. (Refer to 6.10.2 AUX Tab.) " Activation (AUX Output) This is an Air Remote code when the function assigned to the Auxiliary Output port activates. When no function is assigned to “Function” (None), you can control external devices by specifying the decode code. Select the table number configured on the “Decode” tab of the “Encode/Decode Table” window from the dropdown list. (Refer to 6.8 “Encode/ Decode Table” Window.) Note: ! You cannot use the TX Unlock and TXS with Air Remote. (Refer to 6.10 Function Port Window.) ! Although you can use RF Power Down Detect with Air- Remote, the Air Remote code is transmitted with the low transmission power. (Refer to 6.10 Function Port Window.) ! When Dec. Table is already used to the other function, you cannot configure the same Dec. Table. " Deactivation (AUX Output) This is an Air Remote code when the function assigned to the Auxiliary Output port deactivates. When no function is assigned to “Function” (None), you can control external devices by specifying the decode code. Select the table number configured on the “Decode” tab of the “Encode/Decode Table” window from the dropdown list. (Refer to 6.8 “Encode/ Decode Table” Window.) Note: ! You cannot use TX Unlock and TXS with the Air Remote. (Refer to 6.10 Function Port Window.) ! When Dec. Table is already used to the other functions, you cannot configure the same Dec. Table. Range None, Dec. Table 1 - 40, Enc Table 1 - 32 Default None Range None Not send the Transpond code. Fore Sends the Transpond code when receiving the Air Remote code. After Sends the Transpond code after processing the received Air Remote code. Both Sends the Transpond code when receiving the Air Remote code and after processing the received code. Default None Range None, Dec. Table 1 - 40, Enc Table 1 - 32 Default None Range None, Dec. Table 1 - 40, Enc Table 1 - 32 Default None

6 EDIT MENU

47 Field Programming Reference (FPRG) Version: 1.01 " Transponder (AUX Output) This is a timing to send the Transpond code. It can configure only when no function is assign to “Function”. Select one of “None”, “Fore”, “After” and “Both” from the dropdown list. " Logic Type (AUX Output) It can select the status of the signal (Low/High) to activate or deactivate the function with the Air-Remote code. It can configure this function only when no function is assign to “Function”. Select “Active Low” or “Active High” from the dropdown list. Note: The “Logic Type” configured on the “AUX” tab of the “Function Port” window appears when “Function” is configured other than “None”. However, you cannot change the configuration on this window. (Refer to 6.10.2 AUX Tab.) " Activation (AUX Transponder) This is a Transpond code when the function assigned to the Auxiliary port is activated by the Air Remote code and the “Transponder” is configured as “Yes”. (Refer to " Transponder (AUX Input), " Transponder (AUX Output).) Select a table number configured on the “Encode” tab of the “Encode/Decode Table” window from the dropdown list. (Refer to 6.8 “Encode/Decode Table” Window.) Note: You can use Single Tone as the Transpond code when the DTMF signalling is configured. (Refer to " Single Tone (Aux Transponder).) " Deactivation (AUX Transponder) This is a Transpond code when the function assigned to the Auxiliary port is deactivated by the Air Remote code and the “Transponder” is configured as “Yes”. (Refer to " Transponder (AUX Input), " Transponder (AUX Output).) Select a table number configured on the “Encode” tab of the “Encode/Decode Table” window from the dropdown list. (Refer to 6.8 “Encode/Decode Table” Window.) Note: You can use Single Tone as the Transpond code when the DTMF signalling is configured. (Refer to " Single Tone (Aux Transponder).) " Single Tone (Aux Transponder) It can use Single Tone for the Transpond code. Note: You cannot individually select Single Tone for Aux Transponder Activation and Deactivation. Range None Not send the Transpond code. Fore Sends the Transpond code when receiving the Air Remote code. After Sends the Transpond code after processing the received Air Remote code. Both Sends the Transpond code when receiving the Air Remote code and after processing the received Air Remote code. Default None Range Active Low The assigned function activates in Active Low. Active High The assigned function activates in Active High. Default Active Low Range None, Enc Table 1 - 32 Default None Range None, Enc Table 1 - 32 Default None Range Checked Use Single Tone for the Transpond code. Unchecked Not use Single Tone for the Transpond code. Default Unchecked

Field Programming Reference (FPRG)

48 6 EDIT MENU 6.9.3 Remote Access with QT/DQT It can receive the Air Remote code depending on the matched/unmatched status of the received QT/DQT code. Note: ! This function is only available to receive the Air Remote code. This function does not affect the repeat operation. ! If the check box is checked, the QT/DQT Decode function is performed to receive the Air Remote code even when the QT/ DQT Decode function is disabled as following. • The Off-hook Decode function is disabled and the microphone is in the Off-hook position. • The monitor is enable: 6.9.4 Clear To Transpond (Remote Control) This is a timing to transmit a Transpond code. If check box is checked, TKR-750/850/751/851 waits to transmit a Transpond code until the channel is available. 6.10 Function Port Window It can configure the functions that you can assign to the Auxiliary port on this window. This window consists of “AUX Select” and “AUX” tabs and it can switch the window by clicking the tabs. 6.10.1 AUX Select Tab It can select operation type of AUX Input/Output ports on this window. Figure 6-19 AUX Select tab " Function (AUX Select) It can assign this function to the AUX Input/Output ports 1 - 6 only. Select a operation type from “AUX Input”, “AUX Output”, “Channel Select”, and “Multi- table Select”. Note: ! It can assign “Channel Select” and the “Multi-table Select” to the AUX Input/Output ports 1 - 4 only. ! It cannot change the order of the AUX Input/Output ports (1 - 4) when assigning the “Channel Select” function to these ports. If the AUX Input/Output 1" port is assigned the “Multi- table Select”, the “Multi-table Select” function is automatically assigned to AUX Input/Output ports (2 - 4). Range Checked TKR-750/850/751/851 receives the Air Remote code only when the QT/ DQT code matches. Although the it performs the repeat operation, it does not transmit when “TX Disable” is enabled. Unchecked TKR-750/850/751/851 receives the Air Remote code even when the QT/ DQT code does not match or carrier. It cannot enable the repeat operation when the repeat conditions do not match. Default Unchecked Range Checked Waits until the channel becomes available without sending the Transpond code when the channel is busy. Unchecked Sends the Transpond code even if the channel is busy. Default Unchecked Range AUX Input This port works as the PF Input port. AUX Output This port works as the PF Output port. Channel Select Move to one of the CH 1 - CH 16 channels when the voltage level of the Auxiliary Input/Output pots is High or Low. Multi-table Select Specify one of the No. 2 to No. 16 codes configured on the Multi-table when the voltage level of the Auxiliary Input/Output ports is High or Low. Default AUX Input/Output 1 - 5: AUX Input AUX Input/Output 6: AUX Output

6 EDIT MENU

49 Field Programming Reference (FPRG) Version: 1.01 6.10.2 AUX Tab It can configure functions assigned to the AUX Input port, AUX Output port, and the AUX Input/Output port in this tab. Figure 6-20 AUX tab " AUX Input Trigger (AUX Input) This is a method to detect the signal applied to the Auxiliary Input ports Select “Level” or “Down Edge” from the dropdown list. Note: Although TKR-750/850/751/851 performs the detection when the detection is enabled, it performs Start Up first when Start Up is enabled when the “Level” is selected. (Refer to 6.4.3 Others Tab (Optional Features).) " 1st, 2nd, 3rd (AUX Input) You can assign three functions (1st, 2nd, and 3rd) to the AUX Input port and the AUX Input/Output port. Select the functions from the dropdown list. Note: ! As for the AUX Input/Output port, it appears on the list only when it is configured as the “AUX Input” port in the “AUX Select” tab. (Refer to 6.10.1 AUX Select Tab.) ! It cannot configure any functions to “2nd” and “3rd” when “1st” is configured as “None”, and it cannot configure any functions to “3rd” when “2nd” is configured to “None”. Table 6-6 Assigning Functions to the Auxiliary Input Ports (Functions in GLAY are available only when Down Edge is detected.) Range Level Perform the trigger detection when the port is in Active Low. Down Edge Perform the trigger detection with Down Edge on the input signal. Default Level Range Refer to Table 6-6 Assigning Functions to the Auxiliary Input Ports. Default 1st: None 2nd: Cannot be configured. 3rd: Cannot be configured. Function Name Description None Not perform any operation. AUX Out 1 Off - AUX Out 5 Off When the signal is applied to one of the PF [AUX Out 1 Off] - PF [AUX Out 5 Off] input ports, the function assigned to the Auxiliary Output port is deactivated. You can assign this function when “Selectable” is configure to the Auxiliary Output ports 1 to 5. (Refer to Table 6-7 Assigning Functions to the Auxiliary Output Ports.) AUX I/O 1 Off - AUX I/O 6 Off When the signal is applied to one of the PF [AUX Out 1 Off] - PF [AUX Out 6 Off] input ports, the function assigned to the Auxiliary I/O port is deactivated. You can assign the function when “Selectable” is configured to the Auxiliary I/O ports 1 to 6. (Refer to Table 6-7 Assigning Functions to the Auxiliary Output Ports.) AUX Out 1 On - AUX Out 5 On When the signal is applied to one of the PF [AUX Out 1 On] - PF [AUX Out 5 On] input ports, the function assigned to the Auxiliary Output port is activated. You can assign this function when “Selectable” is configure to the Auxiliary Output ports 1 to 5. (Refer to Table 6-7 Assigning Functions to the Auxiliary Output Ports.) AUX I/O 1 On - AUX I/O 6 On When the signal is applied to one of the PF [AUX I/O 1 On] - PF [AUX I/O 6 On] input ports, the function assigned to the Auxiliary I/O port is disabled. You can assign the function when “Selectable” is configured to the Auxiliary I/O ports 1 to 6. (Refer to Table 6-7 Assigning Functions to the Auxiliary Output Ports.) AUX Out 1 On/Off - AUX Out 5 On/Off Switch enable/disable the function assigned to the Auxiliary Output port when the signal is applied to one of the PF [AUX Out 1 On/Off] to PF [AUX Out 5 On/Off] input ports. You can assign this function when “Selectable” is configure to the Auxiliary Output ports 1 to 5. (Refer to Table 6-7 Assigning Functions to the Auxiliary Output Ports.)

Field Programming Reference (FPRG)

50 6 EDIT MENU AUX I/O 1 On/Off - AUX I/O 6 On/Off Switch enable/disable the function assigned to the Auxiliary I/O port when the signal is applied to one of the PF [AUX I/O 1 On/Off] to PF [AUX I/O 6 On/Off] ports. You can assign the function when “Selectable” is configured to the Auxiliary I/O ports 1 to 6. (Refer to Table 6-7 Assigning Functions to the Auxiliary Output Ports.) Channel 1 - Channel 16 Move the channel to one of CH 1 to CH 16 channels when the signal is applied to one of the PF [Channel 1] to PF [Channel 16] ports. You cannot configure this function when “Channel Select” is configured to Auxiliary I/O ports 1 to 4. “E2” appears when specifying the channel without data. (Refer to 6.10.1 AUX Select Tab.) Channel Down Move to the next lower channel when the signal is applied to the PF [Channel Down] input port. The channel without data is skipped. Channel Up Move to the next higher channel when the signal is applied to the PF [Channel Down] input port. The channel without data is skipped. CW ID On Transmit CW ID when the signal is applied to the PF [CW ID On] input port. (Refer to 6.3 CW ID Window.) This function is available on the channel having the CW ID. CW Message 1 - CW Message 8 Transmits one of the CW Messages 1 to 8 when the signal is applied to one of the PF [CW Message 1] to PF [CW Message 8] input ports. (Refer to 6.12 CW Message Window.) DC Power Save Off Switch the Saver Mode Off when the signal is applied to the PF [DC Power Save Off] input port. When the signal is detected with Down Edge, it cannot switch the DC Power Save function On after this function is enabled. DC Power Save On Switch the Save Mode On when the signal is applied to the PF [DC Power Save On] input port. When the signal is detected with Down Edge, it cannot switch the DC Power Save function Off after this function is once enabled. DC Power Save On/Off Switch the Save Mode On/Off when the signal is applied to the PF [DC Power Save On/Off] input port. (Refer to 6.4.3 Others Tab (Optional Features).) Display Off All LEDs other than Power SW LED located on the front panel unlit when the signal is applied to the PF [Display Off] input port. This function is valid for only Power Saver Mode. When the signal is detected with Down Edge, it cannot make all LEDs unlit after this function is enabled. Display On All LEDs on the front panel light when the signal is applied to the PF [Display On] input port. This function is valid for only Power Saver Mode. When the signal is detected with Down Edge, it cannot make all LEDs unlit after this function is enabled. Display On/Off Switch the LEDs located on the front panel On/Off when the signal is applied to the PF [Display On/Off] input port. This function is valid for only Power Saver Mode. Hold Time Disable Switch Repeat Hold Time Off when the signal is applied to the PF [Hold Time Disable] input port. It can configure this function only when at least one channel is configured as the Repeat for Operation mode and Repeat Hold Time is enabled. (Refer to 6.4.1 Optional Features 1 Tab.) When the signal is detected with Down Edge, it cannot switch Hold Time On after this function is enabled. Hold Time Enable Switch Repeat Hold Time On when the signal is applied to the PF [Hold Time Enable] input port. It can configure this function only when at least one channel is configured as the Repeat for Operation mode and Repeat Hold Time is enabled. (Refer to 6.4.1 Optional Features 1 Tab.) When the signal is detected with Down Edge, it cannot switch Hold Time On after this function is enabled. Hold Time Disable/ Enable Switch disable/enable Repeat Hold Time when the signal is applied to the PF [Hold Time Disable/Enable] input port. It can configure this function only when at least one channel is configured as the Repeat for Operation mode and Repeat Hold Time is enabled. (Refer to 6.4.1 Optional Features 1 Tab.) Local TX Disable It can disable the transmissions using the Local Mic PTT when the signal is applied to the PF [Local TX Disable] input port. When the signal is detected with Down Edge, it cannot enable the transmission using the Local Mic PTT after this function is enabled. Local TX Enable It can enable the transmission using the Local Mic PTT when the signal is applied to the PF [Local TX Enable] input port. When the signal is detected with Down Edge, it cannot restrict the transmissions using the Local Mic PTT after this function is enabled. Local TX Disable/Enable Switch disable/enable the transmissions using the Local Mic PTT when the signal is applied to the PF [Local TX Disable/Enable] input port. it can use this function only when the signal is detected with Down Edge. (Refer to " AUX Input Trigger (AUX Input).) Low Power Off *1 Switch the transmission power from Low to High when the signal is applied to the PF [Low Power Off] input port. This function activates only when at least one channel is configured as High Transmission Power. (Refer to 6.2.11 TX High Power.) Function Name Description

6 EDIT MENU

51 Field Programming Reference (FPRG) Version: 1.01 Low Power On *1 Switch the transmission power from High to Low when the signal is applied to the PF [Low Power Off] input port. This function activates only when at least one channel is configured as High Transmission Power. (Refer to 6.2.11 TX High Power.) Low Power On/Off*1 Switch High/Low for the transmission power when the signal is applied to the PF [Low Power On/Off] input port. This function activates only when at least one channel is configured as High for Transmission Power. (Refer to 6.2.11 TX High Power.) Monitor Off It can enable the signalling Decode function when the signal is applied to the PF [Monitor Off] input port. When the signal is detected with Down Edge, you cannot switch Monitor On after this function is once enabled. This function does not operate when the repeater enables the repeat operation. Monitor On It can disable signalling Decode when the signal is applied to the PF [Monitor On] input port. When the signal is detected with Down Edge, you cannot switch Monitor Off after this function is once enabled. Monitor On/Off Switch disable/enable signalling Decode when the signal is applied to the PF [Monitor On/Off] input port. You can use this function only when the signal is detected with Down Edge. (Refer to " AUX Input Trigger (AUX Input).) Multi-table Sub Switch the signalling specified on the Multi-table Select to the Sub-table signalling when the signal is applied to the PF [Multi-table Sub] input port. (Refer to 6.10.1 AUX Select Tab.) When the signal is detected with Down Edge, it cannot switch to the Main-table after the Sub-table is selected. Multi-table Main Switch the signalling specified on the Multi-table Select to the Main-table when the signal is applied to the PF [Multi-table Main] input port. (Refer to 6.10.1 AUX Select Tab.) When the signal is detected with Down Edge, it cannot switch to the Sub-table after the Main-table is selected. Multi-table Main/Sub Switch Main/Sub for the signalling specified with the Multi-table Select when the signal is applied to the PF [Multi-table Main/Sub] input port. (Refer to 6.10.1 AUX Select Tab.) QT/DQT Decode Disable Restrict QT/DQT Decode when the signal is applied to the PF [QT/DQT Decode Disable] input port. When the signal is detected with Down Edge, it cannot switch the QT/DQT Decode function on after this function is on. This function is valid even when the repeater is performing the Repeat operation. QT/DQT Decode Enable Activate QT/DQT Decode when the signal is applied to the PF [QT/DQT Decode Enable] input port. When the signal is detected with Down Edge, it cannot switch the QT/DQT Decode function Off after this function is on. QT/DQT Decode Disable/Enable Switch disable/enable QT/DQT Decode when the signal is applied to the PF [QT/DQT Encode Disable/Enable] input port. QT/DQT Encode Disable Restrict QT/DQT Encode when the signal is applied to the PF [QT/DQT Encode Disable] input port. When the signal is detected with Down Edge, it cannot switch the QT/DQT Encode function On after this function is on. QT/DQT Encode Enable Activate QT/DQT Encode when the signal is applied to the PF [QT/DQT Encode Enable] input port. When the signal is detected with Down Edge, it cannot switch the QT/DQT Encode function Off after this function is on. QT/DQT Encode Disable/Enable Switch disable/enable QT/DQT Encode when the signal is applied to the PF [QT/DQT Encode Disable/Enable] input port. Repeat Disable Restrict the Repeat operation when the signal is applied to the PF [Repeat Disable] input port. It cannot configure this function if no channel is configured to the Repeat operation. When the signal is detected with Down Edge, it cannot enable the Repeat operation after this function is enabled. Repeat Enable Activate the Repeat operation when the signal is applied to the PF [Repeat Enable] input port. It cannot configure this function if no channel is configured to the Repeat operation. When the signal is detected with Down Edge, it cannot disable the repeat operation after this function is enabled. Repeat Disable/Enable Switch disable/enable the repeat operation when the signal is applied to the PF [Repeat Disable/Enable] input port. It cannot configure this function if no channel is configured to the Repeat operation. Reset Reset the operations and returns to the default value when the signal is applied to the PF [Reset] input port. Scan Off It can disable the Scan when the signal is applied to the PF [Scan Off] input port. When the signal is detected with Down Edge, it cannot enable the Scan after this function is enabled. Scan On It can enable the Scan when the signal is applied to the PF [Scan On] input port. When the signal is detected with Down Edge, it cannot disable the Scan after this function is enabled. Scan On/Off Switch Scan On/Off when the signal is applied to the PF [Scan On/Off] input port. Scrambler Off It can disable Scrambler when the signal is applied to the PF [Scrambler Off] input port. It cannot configure this function when the optional Scrambler board is not installed. When the signal is detected with Down Edge, it cannot switch Scrambler On after this function is enabled. Function Name Description

Field Programming Reference (FPRG)

52 6 EDIT MENU Note: ! When assigning similar functions to Auxiliary Input ports, TKR-750/850/751/851 activates the function according to the status of the last used Auxiliary Input port. ! When the same function or similar functions are assigned to the Auxiliary Input port and the PF key, the operation may become unstable due to the chattering. Example: When the PF [Scan On/Off] key is switched from Off to On: • Starts scanning since the Scan starts with the PF [Scan On/Off] key. (Channel/Status display) • Pauses scanning when the signal is applied to the PF [Scan On/Off] input port. ! When the DTMF signalling is configured, TKR-750/850/751/ 851 determines that the received code is a continuous code even when it is intermittently received for a couple seconds. Therefore, it activates the “Reset” function in any of the following cases. Example: TKR-750/850/751/851 assumes that it has received the No. 2 Reset signal when receiving the No. 3 Repeat Disable signal after receiving the No. 1 Take Over On signal. " Function (AUX Output) It can assign the function to the AUX Output port and the AUX Input/Output port. Select the functions from the dropdown list. Note: As for the AUX Input/Output port, it appears on the list only when it is configured as the “AUX Output” port in the “AUX Select” tab. (Refer to 6.10.1 AUX Select Tab.) Scrambler On It can enable Scrambler when the signal is applied to the PF [Scrambler On] input port. It cannot configure this function when the optional Scrambler board is not installed. When the signal is detected with Down Edge, it cannot disable Scrambler after this function is enabled. Scrambler On/Off Switch Scrambler On/Off when the signal is applied to the PF [Scrambler On/Off] input port. It cannot configure this function when the optional Scrambler board is not installed. Squelch Off It can disable Squelch when the signal is applied to the PF [Squelch Off] input port. When the signal is detected with Down Edge, it cannot switch Squelch On after this function is enabled. Squelch On You can enable Squelch when the signal is applied to the PF [Squelch On] input port. When the signal is detected with Down Edge, you cannot switch Squelch Off once this function is enabled. Squelch On/Off Switch Squelch On/Off when the signal is applied to the PF [Squelch On/Off] input port. TA Line Pre-emphasis Off It can disable the pre-emphasis of the TA terminal. It can use this function only when the signal is detected with the Level. TA Line Pre-emphasis On/Off Switch enable/disable the pre-emphasis of the TA terminal. Test Tone Off Stop Test Tone when the signal is applied to the PF [Test Tone Off] input port. When the signal is detected with Down Edge, it cannot switch Test Tone On after this function is on. Test Tone On Start Test Tone when the signal is applied to the PF [Test Tone On] input port. When the signal is detected with Down Edge, it cannot switch Test Tone Off once this function is on. Test Tone On/Off Switch Test Tone On/Off when the signal is applied to the PF [Test Tone On/Off] input port. TOT Disable *2 Disable Time-out Timer when the signal is applied to the PF [TOT Disable] input port. When the signal is detected with Down Edge, it cannot switch Time-out Timer On after this function is on. TOT Enable *2 Enable Time-out Timer when the signal is applied to the PF [TOT Enable] input port. When the signal is detected with Down Edge, it cannot switch Time-out Timer Off after this function is on. TOT Disable/Enable *2 Switch disable/enable Time-out Timer when the signal is applied to the PF [TOT Disable/Enable] input port. TX Disable Restrict all transmissions when the signal is applied to the PF [TX Disable] input port. When the signal is detected with Down Edge, it cannot permit transmissions after this function is on. TX Enable Permit all transmissions when the signal is applied to the PF [TX Enable] input port. When the signal is detected with Down Edge, it cannot restrict transmissions after this function is on. TX Disable/Enable Switch disable/enable the transmissions when the signal is applied to the PF [TX Disable/Enable] input port. *1: This function is available on the TOT of the Local Mic PTT and the Repeater/External PTT. *2: You cannot switch to Low Power while transmitting or scanning. The Low Power status is retained even if the channel is changed or the repeater is turned ON/OFF. Function Name Description Decode Table Assigned Function No. Code 1 0123456 Take Over On 2 0123456789ABCD Reset 3 789ABCD Repeat Disable Range Refer to Table 6-7 Assigning Functions to the Auxiliary Output Ports. Default None Decode Table Assigned Function No. Code

6 EDIT MENU

53 Field Programming Reference (FPRG) Version: 1.01 Table 6-7 Assigning Functions to the Auxiliary Output Ports " Logic Type (AUX Output) It can select the status of the signal (Low/High) to activate or deactivate the function with the Air Remote code. You can configure this function only when at least one function is assign to “Function”. Select “Active Low” or “Active High” from the dropdown list. Function Name Description None Not perform any operation. COR The PF [COR] output port is activated when receiving the signal. Fan Status The PF [Fan Status] output port is activated when the fan starts operating. Power Supply Lower Limit *1 *1: It can configure the any voltage value to detect the voltage decrease/increase. (Refer to 6.4.1 Optional Features 1 Tab.) The PF [Power Supply Lower Level] output port is activated when the power voltage is decreased. RF Power Down Detect *2 *2: It can select High Power or Low Power with “Power Down Detect” in Tuning mode. This function notifies the user that the transmission power is suddenly decreased when the power is decreased, etc. However, you cannot use this function as a real- time power monitor. (Refer to 7.3.11 Tuning Mode.) Default: Hi (25 W) power: Approximately 10 W Low (1 W) power: Approximately 0.3 W Note: ! When configuring the Activation code to the PF [COR] output port or the PF [TOR] output port, TKR-750/850/751/ 851 cannot activate the repeat operation since it sends the code while it is in Busy status, so that it cannot receive the Air Remote code and the Repeater Open code. (Refer to 6.10.2 AUX Tab.) ! Since the status of Air Remote Encode is retained while transmitting using Repeater PTT, Local Mic PTT, or External PTT, or CW ID, TKR-750/850/751/851 cannot send the Activation code even when the function is activated while the Activation code is configured to the PF [Power Supply Lower Limit] output port. In this case, it transmits the Activation code after ending the transmission (the function deactivates). When the Deactivation code is configured to the port, it sends the Deactivation code after transmitting the Activation code. (Refer to 6.10.2 AUX Tab.) The PF [RF Power Down Detect] output port is activated when the transmission power becomes lower than the configured threshold level. Reception Signal (Below) *1 The PF [RX Signal Detect] output port is activated when the RSSI voltage is decreased. Reception Unlock The PF [RX Unlock] output port is activated when RX PLL is unlocked. Selectable Toggle the PF [Selectable] output port between Active/Inactive when the signal is applied to the Auxiliary Input port or the PF key. TOR The PF [TOR] output port is activated when the signalling matches while receiving the signal. The PF [TOR] output port is activated on the channel without the signalling configuration while receiving. TXS The PF [TXS] output port is activated while transmitting. Transmission Unlock The PF [TX Unlock] output port is activated when the TX PLL is unlocked. Range Active Low The assigned function activates in Active Low. Active High The assigned function activates in Active High. Default Active Low

Field Programming Reference (FPRG)

54 6 EDIT MENU 6.11 Multi-table Window It can configure the QT/DQT (Current) code on this window. When the Multi-table function is enabled, it can wait for the call with two types of QT/DQT code; Primary and Current. (Refer to 6.1.6 Multi-table, 6.2.9 Multi-table (Channel Edit).) This window consists of “Main-table” and “Sub-table” tabs and it can switch the window by clicking the tabs. 6.11.1 Decode (Multi-table) It can configure the signalling used to receive the calls. Select the QT tone or DQT code from the dropdown list or directly enter the QT tone and the DQT code. # Selecting the QT/DQT Encode Code from the Dropdown List: # Directly entering the QT/DQT Encode Code: Note: ! It cannot configure the QT/DQT code to the No.1 table. ! It can use numbers, “D”, “N”, “I”, “.”, and “,” for the 5 digits of the QT/DQT Encode code. ! When entering only numbers, the code is configured as QT Tone. ! When entering “D” as the first character of the code, the code is configured as the DQT code. ! When entering the value, which is out of the range, it will be automatically replaced with the highest value or the lowest value in the range. 6.11.2 Encode (Multi-table) It can configure the signalling used to transmit. Select the QT tone or DQT code with the dropdown list or directly enter the QT tone and the DQT code. # When Selecting the QT/DQT Encode Code with the Dropdown List: # Directly entering the QT/DQT Encode Code: Note: ! It cannot configure “Encode” if the “Decode” function is not configured. ! It can use numbers, “D”, “N”, “I”, “.”, and “,” for the 5 digits of the QT/DQT Encode code. ! When entering only numbers, the code is configured as QT Tone. ! When entering “D” as the first character of the code, the code is configured as the DQT code. ! When entering the value, which is out of the range, it will be automatically replaced with the highest value or the lowest value in the range. Range QT 67.0 - 250.3 Hz DQT Normal D023N - D754N DQT Inverse D023I - D754I Default None Range QT 67.0 - 254.1 Hz DQT Normal D000N - D777N DQT Inverse D000I - D777I In steps of QT 0.1 Hz DQT 1 Default None Range QT 67.0 - 250.3 Hz DQT Normal D023N - D754N DQT Inverse D023I - D754I Default None Range QT 67.0 - 254.1 Hz DQT Normal D000N - D777N DQT Inverse D000I - D777I In steps of QT 0.1 Hz DQT 1 Default None

6 EDIT MENU

55 Field Programming Reference (FPRG) Version: 1.01 6.12 CW Message Window It can configure the CW Message to send on this window. You can send the configured CW Message by interlocking with the operation of function keys and the input/output operation of the Auxiliary port. (Refer to 13 FUNCTION LIST.) It can control the transmission of CW Message with the following functions. # Key Function TKR-750/850/751/851 sends the configured CW Message when the PF key is pressed if the CW Message transmission function is assigned to the PF key. (Refer to 6.5 Key Assignment Window.) # Auxiliary Input port TKR-750/850/751/851 sends CW Message when the signal is applied to the Auxiliary Input port if the CW Message transmission function is assigned to the Auxiliary Input port. (Refer to Table 6-6 Assigning Functions to the Auxiliary Input Ports.) # Save On/Off Function TKR-750/850/751/851 sends CW Message when it enters/exists Power Saver mode if the CW Message transmission function is assigned to the Save On/Off function. (Refer to 6.4.3 Others Tab (Optional Features).) # Start Up Function TKR-750/850/751/851 sends CW Message when it is turned ON if the CW Message transmission function is assigned to Start Up. (Refer to 6.4.3 Others Tab (Optional Features).) # Backup Power Function TKR-750/850/751/851 sends CW Message when the power is switched from the main power to the backup power if the CW Message transmission function is assigned to the Backup Power function. (Refer to 6.4.3 Others Tab (Optional Features).) # Main Power Function TKR-750/850/751/851 sends CW Message when the power is switched from the backup power to the main power if the CW Message transmission function is assigned to the Main Power function. (Refer to 6.4.3 Others Tab (Optional Features).) Figure 6-21 “CW Message” window 6.12.1 CW Message It can configure CW Message with a maximum of 32 characters and symbols. Enter directly the message in the edit box. 6.12.2 CW Speed This is a speed to send CW Message. It can configure the speed by the spin buttons or directly enter the value to configure the speed. 6.12.3 CW Mod. Delay Time This is a duration time to send CW message from starts transmitting. It can configure the duration by the spin buttons or directly enter the value to configure the duration. Range No. 1 - 8 A maximum of 32 characters and symbols (space), “, ', (,), +,,, -,., /, 0, 1, 2, 3, 4, 5, 6, 7, 8, 9,:, =,? A - Z Default Blank Range 5 - 30 word/min. In steps of 1 word/min. Default 20 words/min. Range 0, 10 - 2550 ms In steps of 10 ms Default 600 ms

Field Programming Reference (FPRG)

56 6 EDIT MENU 6.12.4 Audio Frequency This is a frequency of CW Message. It can configure the frequency by the spin buttons or directly enter the value to configure the frequency 6.12.5 Send CW Message to RA It allows to monitor CW Message in Morse code when sending the message from the RA line and the front speaker. Note: In Simplex mode, CW Message is sent to RA only. In this case, CW Message is not emitted from the speaker. 6.12.6 Encode with QT/DQT (CW Message) It can encode the QT/DQT (Primary) code configured to each channel while sending the CW Message. 6.13 Test Frequency Window It can configure the test frequency to be used in Test Mode. It can configure a maximum of 16 channels. You can copy the frequency configured in the “Channel Edit” window to the test frequency channel. The available frequency range varies depending on the model and the market code. Figure 6-22 Test Frequency window 6.13.1 Reception, Transmission This is a test frequency. Directly enter the value in the “Reception” edit box and the “Transmission” edit box. Table 6-8 Test Frequency Range Table 6-9 Default Test Frequency of the TKR-750/751 (K) Range 400 - 2000 Hz In steps of 100 Hz Default 800 Hz Range Checked CW Message audio signals sent from the RA line and emitted from the front speaker. Unchecked CW Message audio signals sent from the RA line and emitted from the front speaker. Default Unchecked Range Checked CW Message is sent with primary QT/ DQT signalling. Unchecked CW Message is sent without QT/DQT signalling. Default Unchecked Model Market Code Transmission/Reception Frequency Range [MHz] TKR-750/751 K 146 - 174 TKR-750 K2 136 - 150 TKR-850/851 K 450 - 480 TKR-850 K2 480 - 512 TKR-850 K3 400 - 430 Channel No. Reception Frequency [MHz] Transmission Frequency [MHz] 1 146.10000 146.00000 2 160.10000 160.00000 3 173.90000 174.00000 4 150.10000 150.00000 5 155.10000 155.00000 6 165.10000 165.00000

6 EDIT MENU

57 Field Programming Reference (FPRG) Version: 1.01 Table 6-10 Default Test Frequency of the TKR-850/851 (K) Note: ! It must configure both of the “Reception” frequency and the “Transmission” frequency. ! The default frequency is configured when all frequencies are deleted. ! Refer to the Service Manual for checking how to test the TKR- 750/850/751/851. ! 406.0 MHz and 406.1 MHz are assigned as the Emergency locator beacons in the United States. Therefore, it does not allow designed to use these frequencies. 6.13.2 CH Paste Button Click “CH Paste” to copy the frequency configured in the “Channel Information” window to each channel in the “Test Frequency” window. Note: ! You can view the context menu of the selected channel by right- clicking the channel number. In this window, you can copy or delete the configuration data. ! The default frequency is configured when all frequencies are deleted. 6.14 Embedded Message Window It can configure the message that is stored in the TKR- 750/850/751/851 on the “Embedded Message” window. It can store a message with up to 64 characters (combination of alphabets and numerals). It can embed the specific information, such as the control number or the name of the configuration data written. The Embedded Message appears on the “Open” window when the configuration data is opened. (Refer to 4.2 Open.) Figure 6-23 “Embedded Message” window Directly enter the message in the edit box. 7 170.10000 170.00000 8 158.50000 161.50000 9 161.50000 158.50000 10 136.10000 136.00000 11 151.90000 151.95000 12 152.10000 152.00000 13 - - 14 - - 15 - - 16 - - Channel No. Reception Frequency [MHz] Transmission Frequency [MHz] 1 450.10000 450.00000 2 465.10000 465.00000 3 479.90000 480.00000 4 455.10000 455.00000 5 460.10000 460.00000 6 470.10000 470.00000 7 475.10000 475.00000 8 462.60000 462.50000 9 467.60000 467.50000 10 440.10000 440.00000 11 459.90000 460.00000 12 - - 13 - - 14 - - 15 - - 16 - - Channel No. Reception Frequency [MHz] Transmission Frequency [MHz] Range Maximum of 64 characters and symbols Default Blank

Field Programming Reference (FPRG)

58 6 EDIT MENU 6.15 Embedded Message w/ Password Window It can configure a message and a password into the TKR- 750/850/751/851 on the “Embedded Message w/ Password” window. You can configure a message with up to 64 characters (combination of alphabets and numerals) to the repeater. You can also configure the password to protect the message. You can embed the specific information in it, such as the control number or the name of the configuration data written with a password. Figure 6-24 “Embedded Message w/Password” window Directly enter the message in the edit box. " Write Button This can write the configured message into the TKR- 750/850/751/851. Follow the procedures below to write the message. 1. Click “Write”. The Password Entry display appears. Figure 6-25 Password Entry display Note: The display requiring you to configure the password when the password is not configured. You must configure the password first, then you can write the configured message. 2. Enter the password and click “Write”. 3. Click “OK”. Note: ! The error message appears if you enter an incorrect password. ! The password entry display closes when entering a wrong password three times in a row. ! When writing the message with Embedded Message w/ Password, you can store the message as a separate data from the configuration data. " Password Button It can configure the password and change it. Follow the procedures below to configure/change the password. 1. Click “Password”. The “Caution” window appears. Click “OK” to view the “Password Change” window. Figure 6-26 “Caution” window Figure 6-27 “Password Change” window 2. Enter the password. You can configure a password a maximum of 6 characters. Old Password: Enter the old password in this box. New Password: Enter the new password. Confirm: Enter the same password as the “New Password” to confirm. 3. Click “Write”. 4. Click “OK”. Note: ! The error message appears when the password entered in the “Old Password” box does not match with the registered password. ! The error message appears when the password entered in the “New Password” box does not match with the password entered in the “Confirm” box. ! The password entry display closes when entering an incorrect password three times in a row. Range Maximum of 64 characters and symbols. Default Blank

Field Programming Reference (FPRG)

Version: 1.01 7 PROGRAM MENU 7.1 Read Data from Repeater This function allows to read the configuration data from TKR-750/850/751/851 connected to the PC with the KPG-46 programming cable by KPG-91D. (Refer to 1.2 Connecting to the PC.) Follow the procedures below to read the data. 1. Select one of the following options. • Select “Program” > “Read Data from Repeater”. • Click on the Toolbar. 2. Click “Read”. The PC starts reading the configuration data. # If the Data Password is configured: Click “Read” to view the “Data Password” window. Figure 7-1 “Data Password” window Enter the password in the “Data Password” edit box and click “OK” to start reading the configuration data. Note: ! Embedded Message appears if the message has embedded message. ! The error message appears if you enter a wrong password. The “Data Password” window closes when entering an incorrect password three times in a row. The data reading completion message appears when the PC correctly reads the confirmation from the repeater. 3. Click “OK”. Note: ! The PC cannot read the configuration data when TKR-750/ 850/751/851 does not respond even if “Read” is clicked. In this case, you must ensure the power of TKR-750/850/751/ 851 and the connection between the PC, and then start the operation again. ! The error message appears when the Com port does not open and you cannot read the configuration data. In this case, you must ensure the COM port configuration in “Communication Port”, and then start the operation again. (Refer to 9.1 Communication Port Window.) 7.2 Write Data to Repeater This function allows to write the configuration data into TKR-750/850/751/851 connected to the PC with the KPG-46 programming cable by KPG-91D. (Refer to 1.2 Connecting to the PC.) Follow the procedures below to write the configuration data. 1. Select one of the following options. • Select “Program” > “Write Data to Repeater”. • Click on the Toolbar. 2. Click “Write”. The PC starts writing the configuration data. # If the “Data Password” is configured: The warning message appears when clicking “Write”. Figure 7-2 Warning message Click “OK” to start writing the configuration data. The data writing completion message appears when the PC properly writes the confirmation. 3. Click “OK”. Note: ! The PC cannot write the configuration data when TKR-750/ 850/751/851 does not respond even if “Write” is clicked. In this case, you must ensure the power of TKR-750/850/751/ 851and the connection between the PC and start the operation again. ! The error message appears when the COM port is not available and you cannot write the configuration data. In this case, you must ensure that COM port is available in the “Communication Port” configuration, and then start the operation again. (Refer to 9.1 Communication Port Window.) 7.3 Test Mode Window It can configure the data used to perform various tests and adjustments in the “Test Mode” window when operating the TKR-750/850/751/851 in Test mode. In this mode, you can make various adjustments, such as checking the RF environment of the location and the adjustment of the reception frequency, before installing or operating the TKR-750/850/751/851. You can start the test without writing data since the encode/decode signalling and the test frequency are already configured. (Refer to 6.13 Test Frequency Window.)

Field Programming Reference (FPRG)

61 7 PROGRAM MENU You can modify the test and other configuration data by KPG-91D. Figure 7-3 “Test Mode” window Note: ! The cooling Fan is switched On operates in PC Test Mode. ! Refer to the Service Manual for checking how to test. 7.3.1 Test Channel It can select the channel to test. You can select the numbers of the channel configured on the “Test Frequency” window by the spin buttons. (Refer to 6.13 Test Frequency Window.) The frequency configured to the selected channel number appears on the “Frequency” window. Note: You cannot select the number of the channel that is not configured on the “Test Frequency” window. 7.3.2 Test Signalling It can select the test signalling. Select the number of the test signalling that is already configured by the spin buttons. The Decode Tone/Encode Tone configured to the selected signalling Number appears on the “Frequency” window. signalling No.: signalling No. of the Test Mode Decode Tone: Reception signalling Encode Tone: Transmission signalling Table 7-1 Test Signalling Note: TKR-750/850/751/851 deactivates AF Mute when the signalling is decoded with the QT/DQT code and the signalling matches. Range 1 - 16 Default 1 Range Test signalling No. 1 - 16 Default 1 signalling No. Decode tone Encode tone 1 None None 2 None 100 Hz square wave 3 QT 67.0 Hz QT 67.0 Hz 4 QT 151.4 Hz QT 151.4 Hz 5 QT 210.7 Hz QT 210.7 Hz 6 QT 250.3 Hz QT 250.3 Hz 7 DQT D023N DQT D023N 8 DQT D754I DQT D754I 9 None CW ID Encode [ID = VVV] 10 None Single Tone [1000 Hz] 11 DTMF 159D DTMF 159D 12 None DTMF Tone 9 13 None Courtesy Tone*1 *1: The value configured in the “Optional Features 2" tab. (Refer to 6.4.2 Optional Features 2 Tab.) 14 None Battery Warning Tone*1 15 None Battery Operation Tone*1 16 - -

7 PROGRAM MENU

62 Field Programming Reference (FPRG) Version: 1.01 7.3.3 Wide/ Narrow It can select the Bandwidth for the Test Channel. Select from Wide and Narrow from the dropdown list. (Refer to FUNC 1.4 Transmission Bandwidth.) 7.3.4 Beat Shift (Test Mode) It can select the Beat Shift function to the Test Channel. The Beat Shift function eliminates the problems of the internal beat caused by internal oscillators. Select “Yes” or “No” from the dropdown list. 7.3.5 Power (Test Mode) It can select the transmit output power for the Test Channel. Select “High” or “Low” from the dropdown list. 7.3.6 Monitor (Test Mode) It can enable/disable Squelch of the Test Channel. Select “Off” or “On” from the dropdown list. 7.3.7 Compander (Test Mode) It can select Compander for the Test Channel. This function improves the quality of the received tone by reducing the noise. Select “Off” or “On” from the dropdown list. 7.3.8 Repeat It can configure Repeat operation to the Test Channel. Select “Off” or “On” from the dropdown list. 7.3.9 TX/RX Button Click “TX/RX” to toggle between transmission and reception. 7.3.10 Print Button Click “Print” to print out the configured Tuning Data. 7.3.11 Tuning Mode It can make various adjustments for the TKR-750/850/ 751/851 by the KPG-91D. Double-click the function in the list box in the “Test Mode” window to view the adjustment window of the selected function. (Refer to Table 7-2 Functions that you can adjust in PC Tuning Mode.) Figure 7-4 Example: “Frequency Adjustment” window Note: Refer to the Service Manual how to adjust the TKR-750/850/ 751/851 also. Range Wide, Narrow Default Wide Range Yes The Beat Shift function is enabled. No The Beat Shift function is disabled. Default No Range High, Low Default High Range Off Squelch is disabled. On Squelch is enabled. Default Off Range Off Compander is disabled. On Compander is enabled. Default Off Range Off Repeat is disabled. On Repeat is enabled. Default Off

Field Programming Reference (FPRG)

63 7 PROGRAM MENU Table 7-2 Functions that you can adjust in PC Tuning Mode Function Wide/ Narrow Description Signalling Reception Frequency - You can adjust the VCO frequency during reception. TKR-750/751 (VHF): Single Reference Level Adjustment TKR-850/851 (UHF): Single Reference Level Adjustment Reception Frequency (Low) - You can adjust the VCO frequency during reception. TKR-750/751 (VHF) only: Single Reference Level Adjustment You can make the adjustment in steps of 2.5 kHz. Reception Frequency (High) - You can adjust the VCO frequency during reception. TKR-750/751 (VHF) only: Single Reference Level Adjustment You can make the adjustment in steps of 2.5 kHz. Transmission Frequency - You can adjust the VCO frequency during transmission. TKR-750/751 (VHF): Single Reference Level Adjustment TKR-850/851 (UHF): Single Reference Level Adjustment Transmission Frequency (Low) - You can adjust the VCO frequency during transmission. TKR-750/751 (VHF) only: Single Reference Level Adjustment You can make the adjustment in steps of 2.5 kHz. Transmission Frequency (High) - You can adjust the VCO frequency during transmission. TKR-750/751 (VHF) only: Single Reference Level Adjustment You can make the adjustment in steps of 2.5 kHz. Squelch Tight Wide You can adjust the Squelch Level 15. Single Reference Level Adjustment Narrow Squelch Open Wide You can adjust the Squelch Level 1. Single Reference Level Adjustment The TKR-750/850/751/851 stores the RSSI Level at the same time. Narrow RD (RX Detector Output) Level Wide You can adjust the RD (RX Detector Signal Output) level. Single Reference Level Adjustment Narrow RA (RX Audio Output) Level Wide You can adjust the RA (RX Audio Signal Output) level. Single Reference Level Adjustment Narrow TX High Power - You can adjust the TX High Power level. High Power: 3 Reference Level Adjustments TX Low Power - You can adjust the TX Low Power level. Low Power: 3 Reference Level Adjustments Power Down Detect (High) - You can configure the threshold level to detect the degradation of the output power while transmitting in High Power mode. Single Reference Level Adjustment Power Down Detect (Low) - You can configure the threshold value to detect the degradation of the output power while transmitting in Low Power mode. Single Reference Level Adjustment Max Deviation Wide You can adjust the Maximum Deviation level. TKR-750/751 (VHF): 6 Reference Level Adjustments (3 Reference levels for VCO A and B) TKR-850/851 (UHF): 3 Reference Level Adjustments Narrow DQT Balance Wide You can adjust the DQT Encode balance. TKR-750/751 (VHF): 2 Reference Level Adjustments TKR-850/851 (UHF): Single Reference Level Adjustment Sig CH = 2 Narrow TD (Ext. Signalling) Deviation Wide You can adjust the TD (external signalling) level. TKR-750/751 (VHF): 2 Reference Level Adjustments TKR850/-851 (UHF): Single Reference Level Adjustment Narrow TA (TX Audio) Deviation Wide You can adjust the TA (TX Audio) level. TKR-750/751 (VHF): 2 Reference Level Adjustments TKR-850/851 (UHF): Single Reference Level Adjustment Narrow

7 PROGRAM MENU

64 Field Programming Reference (FPRG) Version: 1.01 Note: Deviation is the frequency modulation bandwidth. DQT Deviation Wide You can adjust the DQT Encode level. TKR-750/751 (VHF): 2 Reference Level Adjustments TKR-850/851 (UHF): Single Reference Level Adjustment Sig CH = 7 Narrow QT Deviation Wide You can adjust the QT Encode level. TKR-750/751 (VHF): 2 Reference Level Adjustments TKR-850/851 (UHF): Single Reference Level Adjustment Sig CH = 4 Narrow CW ID Deviation Wide You can adjust the CW ID Encode level. TKR-750/751 (VHF): 2 Reference Level Adjustments TKR-850/851 (UHF): Single Reference Level Adjustment Sig CH = 10 Narrow Test Tone Deviation Wide You can adjust the Test Tone (single tone) Encode level. TKR-750/751 (VHF): 2 Reference Level Adjustments TKR-850/851 (UHF): Single Reference Level Adjustment Sig CH = 10 Narrow DTMF Deviation Wide You can adjust the DTMF Encode level. TKR-750/751 (VHF): 2 Reference Level Adjustments TKR-850/851 (UHF): Single Reference Level Adjustment Sig CH = 12 Narrow Courtesy Tone Deviation Wide You can adjust the Courtesy Tone Encode level. TKR-750/751 (VHF): 2 Reference Level Adjustments TKR-850/851 (UHF): Single Reference Level Adjustment Configurati on value in the KPG- 91D Narrow Buttery Warning Tone Deviation Wide You can adjust the Battery Warning Tone Encode level. TKR-750/751 (VHF): 2 Reference Level Adjustments TKR-850/851 (UHF): Single Reference Level Adjustment Configurati on value in the KPG- 91D Narrow Buttery Operation Tone Deviation Wide You can adjust the Battery Operation Tone Encode level.TKR-750/751 (VHF): 2 Reference Level Adjustments TKR-850/851 (UHF): Single Reference Level Adjustment Configurati on value in the KPG- 91D Narrow Repeat Gain Wide You can adjust the Repeat Audio level. Single Reference Level Adjustment Narrow Function Wide/ Narrow Description Signalling

Field Programming Reference (FPRG)

Version: 1.01 8 TOOLS MENU 8.1 Radio Information Window The information configured in the TKR-750/850/751/851 appears on the “Radio Information” window. The “Radio Information” window appears when selecting “Radio Information” in the “Tools” menu. Figure 8-1 “Radio Information” window 8.1.1 Model Type The model type of the TKR-750/850/751/851 appears. (Refer to 5.1.1 Model Type.) 8.1.2 Frequency The frequency bandwidth configured to the TKR-750/850/ 751/851 appears. (Refer to 5.1.2 Frequency.) 8.1.3 Serial Number The serial number assigned to the TKR-750/850/751/851 appears. 8.1.4 Checksum The checksum which is firmware version appears.

Field Programming Reference (FPRG)

66 9 SETUP MENU 9.1 Communication Port Window It can select the COM port to communicate with the TKR- 750/850/751/851. When there is only one available Communication port on a PC, the port is automatically configured as COM1. The “Communication Port” window appears when selecting “Communication Port” in the “Setup” menu. Figure 9-1 Communication Port window Select the Communication Port from COM1 - COM20 and click “OK”. 9.2 Language File Setup Window It can select the language on “Language File Setup” window. Figure 9-2 “Language File Setup” window From the dropdown list, Select the language. Note: The selected language in the “Language File Setup” window is applied to all KPG-91D software functions. Range Dutch, English, French, German, Italian, Spanish Default The language selected when installing the software appears.

Field Programming Reference (FPRG)

Version: 1.01 10 VIEW MENU 10.1 Tree View Window This window displays the functions in the “Edit” menu. Double-click each item to display the window of the selected item. Figure 10-1 “Tree View” window 10.2 Toolbar It can display/hide the toolbar. You can display or hide the Toolbar by selecting “View” > “Toolbar”. (Refer to 3.1.3 Toolbar.) 10.3 Status Bar It can display/hide the Status bar. You can display or hide the Status bar by selecting “View” > “Status Bar”. (Refer to 3.1.4 Status Bar.)

Field Programming Reference (FPRG)

68 11 WINDOW MENU The “Window” menu appears when the function is selected in the “Edit” menu and the window of the function is displayed. You can rearrange and close the opened windows. (Refer to 3.2.8 “Window” Menu.) 11.1 Cascade You can rearrange the opened windows in an overlapped fashion (cascade format) by selecting “Cascade”. Figure 11-1 Cascade 11.2 Horizontal Tile You can rearrange the opened windows in the horizontal tiles fashion by selecting “Horizontal Tile”. Figure 11-2 Horizontal Tile 11.3 Vertical Tile You can rearrange the opened windows in the vertical tiles fashion by selecting “Vertical Tile”. Figure 11-3 Vertical Tile 11.4 Arrange Icons You can rearrange the icons of the minimized windows by selecting “Arrange Icons”. Figure 11-4 Arrange Icons

11 WINDOW MENU

69 Field Programming Reference (FPRG) Version: 1.01 11.5 Close All Windows You can close all opened windows by selecting “Close All Windows”. 11.6 Opened Window List You can display the title of the opened window. When clicking the title of the window, the selected window appears. Figure 11-5 Opened Window List

Field Programming Reference (FPRG)

70 12 HELP MENU 12.1 Help Topics Window You can view the “KPG-91D Help” window by selecting “Help” > “Help Topics”. In this window, you can search for the help topics relating to the operations and functions of the KPG-91D. This window consists of “Contents”, “Index”, and “Search” tabs and you can switch the window by clicking the tabs. (Refer to 3.2.9 “Help” Menu.) 12.1.1 Contents Tab You can search for the help topics from the menu bar. The menu bar has 8 items; File, Model, Edit, Program, Tools, Setup, View, and Window. Figure 12-1 Contents tab The help text appears in the right frame of the “Help” window when clicking ILG or . You can view the detailed help text on the when double-clicking the or clicking . 12.1.2 Index Tab You can search the help topic from the Keyword list. Enter the keyword into the edit box, then click the keyword from the Keyword List or click “Display”. 12.1.3 Search Tab You can search the help topic with the word or phrases in the document. Enter the keyword into the edit box, then double-click the keyword or click “Display”. 12.2 About KPG-91D Window You can view the “About KPG-91D Help” window by selecting “Help” → “About KPG-91D”. You can view the information about the KPG-91D. Figure 12-2 “About KPG-91D” window Click “OK” to close the “About KPG-91D” window.

Field Programming Reference (FPRG)

71 13 FUNCTION LIST Refer to the PF key, AUX Input port, Save On/Off, Start Up, and Power Supply sections for details. PF key (Refer to 6.5 Key Assignment Window.) AUX Input port (Refer to 6.10.2 AUX Tab.) Save On/Off (Refer to 6.4.3 Others Tab (Optional Features).) Start Up (Refer to 6.4.3 Others Tab (Optional Features).) Power Supply (Refer to 6.4.3 Others Tab (Optional Features).) Table 13-1 Function List Y: Available function N: Unavailable function Function PF Key AUX Input Save On/Off Start Up Power Supply None Y Y Y Y Y AUX Out 1 Off N Y Y Y Y AUX Out 2 Off N Y Y Y Y AUX Out 3 Off N Y Y Y Y AUX Out 4 Off N Y Y Y Y AUX Out 5 Off N Y Y Y Y AUX I/O 1 Off N Y Y Y Y AUX I/O 2 Off N Y Y Y Y AUX I/O 3 Off N Y Y Y Y AUX I/O 4 Off N Y Y Y Y AUX I/O 5 Off N Y Y Y Y AUX I/O 6 Off N Y Y Y Y AUX Out 1 On N Y Y Y Y AUX Out 2 On N Y Y Y Y AUX Out 3 On N Y Y Y Y AUX Out 4 On N Y Y Y Y AUX Out 5 On N Y Y Y Y AUX I/O 1 On N Y Y Y Y AUX I/O 2 On N Y Y Y Y AUX I/O 3 On N Y Y Y Y AUX I/O 4 On N Y Y Y Y AUX I/O 5 On N Y Y Y Y AUX I/O 6 On N Y Y Y Y AUX Out 1 On/Off Y Y* N N N AUX Out 2 On/Off Y Y* N N N AUX Out 3 On/Off Y Y* N N N AUX Out 4 On/Off Y Y* N N N AUX Out 5 On/Off Y Y* N N N AUX I/O 1 On/Off Y Y* N N N AUX I/O 2 On/Off Y Y* N N N AUX I/O 3 On/Off Y Y* N N N AUX I/O 4 On/Off Y Y* N N N AUX I/O 5 On/Off Y Y* N N N AUX I/O 6 On/Off Y Y* N N N Channel 1 Y Y Y Y Y Channel 2 Y Y Y Y Y Channel 3 Y Y Y Y Y Channel 4 Y Y Y Y Y Channel 5 Y Y Y Y Y Channel 6 Y Y Y Y Y Channel 7 Y Y Y Y Y Channel 8 Y Y Y Y Y Channel 9 Y Y Y Y Y Channel 10 Y Y Y Y Y Channel 11 Y Y Y Y Y Channel 12 Y Y Y Y Y Channel 13 Y Y Y Y Y Channel 14 Y Y Y Y Y Channel 15 Y Y Y Y Y Channel 16 Y Y Y Y Y Channel Down Y Y Y Y Y Channel Up Y Y Y Y Y CW ID On Y Y Y Y Y Function PF Key AUX Input Save On/Off Start Up Power Supply

13 FUNCTION LIST

72 Field Programming Reference (FPRG) Version: 1.01 CW Message 1 On Y Y Y Y Y CW Message 2 On Y Y Y Y Y CW Message 3 On Y Y Y Y Y CW Message 4 On Y Y Y Y Y CW Message 5 On Y Y Y Y Y CW Message 6 On Y Y Y Y Y CW Message 7 On Y Y Y Y Y CW Message 8 On Y Y Y Y Y DC Power Save Off N Y N Y Y DC Power Save On N Y N Y Y DC Power Save On/Off Y Y* N N N Display Off N Y Y Y Y Display On N Y Y Y Y Display On/ Off Y Y* N N N Hold Time Enable N Y Y Y Y Hold Time Disable N Y Y Y Y Hold Time Dis/En Y Y* N N N Local TX Disable N Y Y Y Y Local TX Enable N Y Y Y Y Local TX Dis/ En Y Y* N N N Monitor Off N Y Y Y Y Monitor On N Y Y Y Y Monitor On/ Off Y Y* N N N Function PF Key AUX Input Save On/Off Start Up Power Supply Monitor Momentary Y N N N N Multi Table Sub N Y Y Y Y Multi Table Main N Y Y Y Y Multi Table Main/Sub Y Y* N N N QT/DQT Dec. Disable N Y Y Y Y QT/DQT Dec. Enable N Y Y Y Y QT/DQT Dec. Dis/En Y Y* N N N QT/DQT Enc Disable N Y Y Y Y QT/DQT Enc Enable N Y Y Y Y QT/DQT Enc Dis/En Y Y* Y N Y Repeat Disable N Y Y Y Y Repeat Enable N Y Y Y Y Repeat Dis/ En Y Y* N N N Reset Y Y N N N Scan Off N Y Y Y Y Scan On N Y Y Y Y Scan On/Off Y Y* N N N Scrambler Off N Y Y Y Y Scrambler On N Y Y Y Y Scrambler On/Off Y Y* N N N Squelch Off N Y Y Y Y Squelch On N Y Y Y Y Squelch On/ Off Y Y* N N N Squelch Momentary Y N N N N TA line Pre- emphasis Off N Y** N N N TA line Pre- emphasis On/ Off N Y* N N N Take Over On/Off Y N N N N Function PF Key AUX Input Save On/Off Start Up Power Supply

Field Programming Reference (FPRG)

73 13 FUNCTION LIST *: You can use this function only when the signal is detected with the Down Edge. **: You can use this function only when the signal is detected with the Level. Test Tone Off N Y Y Y Y Test Tone On N Y Y Y Y Test Tone On/ Off Y Y* N N N TOT Disable N Y Y Y Y TOT Enable N Y Y Y Y TOT Dis/En Y Y* N N N TX Disable N Y Y Y Y TX Enable N Y Y Y Y TX Dis/En Y Y* N N N Low Power Off N Y Y Y Y Low Power On N Y Y Y Y Low Power On/Off Y Y* N N N Function PF Key AUX Input Save On/Off Start Up Power Supply

Field Programming Reference (FPRG)

I INDEX Symbols "Edit" Menu ..............................5 "File" menu ..............................5 "Help" menu..............................7 "Model" Menu.............................5 "Program" menu ...........................6 "Setup" menu .............................6 "Tools" menu .............................6 "View" menu..............................7 "Window" menu ...........................7 * and # Digit Time .........................41 Numerics 1st, 2nd, 3rd (AUX Input.....................49 A AUX Input Trigger (AUX Input) ................49 AUX Input/Output tab ......................45 AUX Select tb............................48 AUX tab................................49 About KPG-91D window ....................70 Activation (AUX Input) ......................45 Activation (AUX Output).....................46 Activation (AUX Transponder) ................47 Activation (PF Key Transponder)...............45 Activation (PF Key) ........................44 Arrange Icons............................68 Assigning Functions to the Auxiliary Input Ports 49, 53 Assigning Functions to the Auxiliary Output Ports ...53 Assigning functions to the PF Keys .............37 Audio Frequency......................25, 56 B Backup Battery Operation Tone ...............32 Backup Battery Operation Tone Frequency .......32 Backup Battery Operation Tone Interval..........33 Backup Battery Operation Tone Send to RA .......33 Backup Battery System .....................28 Backup Battery Warning Tone ................32 Backup Battery Warning Tone Frequency ........32 Backup Battery Warning Tone Send to RA ........32 Backup Power Function .....................36 Beat Shift...............................23 Beat Shift (Test Mode)......................62 Busy Channel Lockout......................31 C CW ID .............................24, 25 CW ID Override ..........................26 CW ID button ............................24 CW ID on Channel Change ..................26 CW ID window ...........................25 CW Message ............................55 CW Message window ......................55 CW Mod. Delay Time.......................55 CW Mod.Delay Time .......................25 CW Speed ..........................25, 55 Cascade ...............................68 Ch Paste button ..........................57 Channel Copy........................19, 24 Channel Delete...........................20 Channel Edit button........................19 Channel Edit window .......................21 Channel Information window..................17 Channel Insert ...........................20 Channel Name .......................18, 22 Clear To Transpond (Remote Control) ...........48 Closes All Windows........................69 Communication Port window..................66 Communication port ........................1 Compander .............................24 Compander (Test Mode) ....................62 Conditions to Activate the Air Remote Function .....43 Connecting the TKR-751/851 to the PC ...........1 Context Menu............................21 Control Tone ............................32 Courtesy Tone ...........................33 Courtesy Tone Frequency ...................33 Courtesy Tone Period ......................33 Courtesy Tone Send to RA...................33 D DQT Turn-off Code ........................28 DTMF Speed ............................41 DTMF window............................41 Data Password ...........................29 Deactivation (AUX Input) ....................46 Deactivation (AUX Output) ...................46 Deactivation (AUX Transponder)...............47 Deactivation (PF Key Transponder) .............45 Deactivation (PF Key) ......................44 Decode (Multi-table) .......................54 Decode Code ............................42 Displaying Help............................3 Dropout Delay Time........................40 Dwell Time..............................40 E Edit menu ..............................17 Editing the Configuration Data and Writing to the Repeater ...........................3 Embedded Message w/Password window ........58 Embedded Message window .................57 Encode (Multi-table) .......................54 Encode Tone in Multiple.....................23 Encode with QT/DQT (CW ID) ................26 Encode with QT/DQT CW Message.............56 Encode/Decode Table Window ................42

Field Programming Reference (FPRG)

Version: 1.01 External Monitor.......................... 29 F Fan Action.............................. 29 File menu .............................. 10 Firmware Program ........................ 30 First Digit Delay Time ...................... 41 First Digit Time........................... 41 Frequency .......................... 16, 42 Frequency Copy.......................... 20 Function (AUX Input)....................... 45 Function (AUX Output) ................. 46, 52 Function (AUX Select)...................... 48 Function (PF Key)......................... 44 Function List ............................ 71 Function Port window ...................... 48 Functions that you can adjust in PC Tuning Mode... 63 H Help Menu.............................. 70 Help Topics window ....................... 70 Horizontal Tile ........................... 68 I Initializing the Window....................... 3 Installing the KPG-91D ...................... 1 K KPG-91D................................ 1 Key Assignment window .................... 37 L Language File Setup window ................. 66 Logic Type (AUX Output)................ 47, 53 Look Back Time A ........................ 39 Look Back Time B ........................ 39 M Main Power Function ...................... 36 Main window ............................. 4 Menu bar................................ 4 Model Information window ................... 16 Model Type ............................. 16 Model menu............................. 16 Modifying the configuration data ................ 3 Monitor (Test Mode) ....................... 62 Multi-table (Channel Edit) ................... 23 Multi-table (Channel Information) .............. 18 Multi-table window ........................ 54 O Off-hook Decode ......................... 29 Off-hook Scan ........................... 40 Opened Window List.......................69 Operation Mode ......................19, 23 Optional Board ...........................16 Optional Features 1 tab .....................27 Optional Features 2 tab .....................31 Optional Features window ...................27 Others tab (Optional Features) ................34 P PF Key tab..............................44 PTT Priority .............................30 Password button..........................58 Period .................................42 Power .................................19 Power (Test Mode) ........................62 Power On Tone ..........................32 Power Supply Lower Level...................28 Print ..................................11 Print Out List ............................12 Print button .............................62 Priority ................................39 Priority Channel ..........................39 Program menu ...........................60 Q QT Decode Delay .........................28 QT Reverse Burst.........................24 QT Reverse Burst Time.....................28 QT/DQT Copy ...........................20 QT/DQT Decode......................17, 22 QT/DQT Encode......................18, 22 R RX Signal Detect (Below)....................29 Radio Information window ...................65 Read Data from Repeater ...................60 Reception Frequency ..................17, 21 Reception, Transmission ....................56 Remote Access with QT/DQT.................48 Remote Control window.....................43 Repeat ................................62 Revert Channel ..........................39 S Save Delay Timer A .......................36 Save Delay Timer B .......................36 Save Mode Duration .......................36 Save Off Function.........................36 Save On Function.........................36 Scan Add...........................19, 24 Scan Information window....................39 Scrambler Backup ........................30 Scrambler Code ..........................24 Send CW ID to RA ........................26 Send CW Message to RA ...................56

Field Programming Reference (FPRG)

III CONTENTS Setup menu .............................66 Shortcut Keys.............................8 Sidetone ...............................42 Single Tone (Aux Transponder) ...............47 Single Tone (PF Key Transponder) .............45 Squelch Level............................28 Start Up................................36 Starting and Exiting the KPG-91D ...............3 Status bar ...............................5 System Requirements .......................1 T TOT Rekey Time (Local Mic PTT) ..............31 TOT Reset Time (Local Mic PTT) ..............31 TX Delay Time ...........................25 TX High Power ...........................23 TX Interval Time ..........................25 TX Required in Interval .....................26 TX Standby on Frequency ...................30 TX/RX Button ............................62 Test Channel ............................61 Test Frequency window .....................56 Test Mode window ........................60 Test Signalling ...........................61 Test Tone ..............................28 Time-out Pre-alert (Local Mic PTT) .............31 Time-out Timer (Local Mic PTT) ...............31 Title Bar.................................4 Tone Volume ............................31 Toolbar .................................4 Tools menu .............................65 Transmission Frequency ....................22 Transponder (AUX Input) ....................46 Transponder (AUX Output)...................47 Transponder (PF Key) ......................44 Tree View window.........................67 Tuning Mode ............................62 U Uninstalling the KPG-91D ....................2 V Vertical Tile .............................68 View menu..............................67 Voice Scrambler ..........................24 W W/N ..................................18 Warning Alert Tone ........................32 Wide/Narrow ........................23, 62 Window menu ...........................68 Write Data to Repeater .....................60 Write button .............................58 Writing the configuration data to the Repeater.......3 Z Channel Delete (..........................20

Other Radio Manuals