LEGRAND 0 489 35 Cat. No(s): 0 489 35

Technical data sheet: S000088482EN-1 Updated: Created: 02/01/2017 1/8 PIR+US ceiling mount sensors (DALI) CONTENTS Page 1. Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2. Technical characteristics . . . . . . . . . . . . . . . . . 1 3. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 4. Dimensions . . . . . . . . . . . . . . . . . .

Technical data sheet: S000088482EN-1

Updated: Created: 02/01/2017 Cat. No(s): 0 489 35 PIR+US ceiling mount sensors (DALI) CONTENTS  3.1 Sensor location  3.2 Recommended light exposure 3. INSTALLATION US PIR 2.5 m 1.5 m  3.3 Mounting  3.4 Recommended light exposure  3.5. Removal 3. INSTALLATION (CONTINUED) 0.3 to 20 mm Ø 65 Ø 65 Ø 68 Ø 68 50 0 488 75 Ø 120 Ø 120
Technical data sheet: S000088482EN-1 Updated: Created: 02/01/2017 Cat. No(s): 0 489 35 PIR+US ceiling mount sensors (DALI) CONTENTS 4. DIMENSIONS 50 58 50 Ø : 122  5.1 Wiring with a single sensor: 5. CONNECTION D  5.2 Wiring with several sensors 5. CONNECTION (CONTINUED) D x 64 max. 0 488 72 Cat. Nos. 0 035 13/15 200 mA max. D ≤ 100 m 0.5 mm2 ≤ 150 m 0.75 mm2 ≤ 300 m 1.5 mm2 25 mA 2 mA 0 488 72 Cat. Nos. 0 035 13/15 200 mA max. x 64 max.
Technical data sheet: S000088482EN-1 Updated: Created: 02/01/2017 Cat. No(s): 0 489 35 PIR+US ceiling mount sensors (DALI) CONTENTS  5.3 Wiring with several sensors and one control unit: 5. CONNECTION (CONTINUED) 5. CONNECTION (CONTINUED) 0 488 78 • The push-button must be connected to a master sensor via Cat. No. 0 488 78. 150m. max. D D ≤ 100 m 0.5 mm2 ≤ 150 m 0.75 mm2 ≤ 300 m 1.5 mm2 25 mA 2 mA  5.4 Wiring with several sensors,
Technical data sheet: S000088482EN-1 Updated: Created: 02/01/2017 Cat. No(s): 0 489 35 PIR+US ceiling mount sensors (DALI) CONTENTS  6.1 TEST function  6.2 Configuration Configuration of a DALI installation is described in the DALI programming manual. 7. SETTINGS  7.1 Detection settings Time delay: Length of time the load is on after detection. Pulse mode (= push-button mode): If the time delay is set to 0, the sensor is in push-button mode. I
Technical data sheet: S000088482EN-1 Updated: Created: 02/01/2017 Cat. No(s): 0 489 35 PIR+US ceiling mount sensors (DALI) CONTENTS  7.2 Light level settings Advanced mode: Calibration: The ambient light level measured with a luxmeter must then be transmitted to the sensor. Regulation: Automatic switch-off of the load 10 minutes after the daylight setpoint is exceeded with an additional safety threshold (to avoid lights switching off at the wrong mo
Technical data sheet: S000088482EN-1 Updated: Created: 02/01/2017 Cat. No(s): 0 489 35 PIR+US ceiling mount sensors (DALI) CONTENTS  8.4 US - Presence detection Keep the lens clean. Clean the surface with a cloth. Do not use acetone, tar-removing cleaning agents or trichloroethylene. Resistant to the following products: - Hexane - Methylated spirit - Soapy water - Diluted ammonia - Bleach diluted to 10% - Window-cleaning products Caution: Always tes