LG LS091HSV3 Engineering Manual

Specifications

Brand: LG
Category: Air Conditioner
Model: LS091HSV3 (Engineering Manual)
File Type: PDF
File Size: —
Pages: 76

Read Online

Read the LG LS091HSV3 Engineering Manual online using the built-in PDF viewer.

Text of the manual

SINGLE ZONE HIGH EFFCIENCY, STANDARD AND

EXTENDED PIPE WALL MOUNT ENGINEERING MANUAL Single Zone Wall Mount Systems 3/4 to 2-3/4 Tons

For continual product development, LG Electronics U.S.A., Inc., reserves the right to change specifications without notice.

©LG Electronics U.S.A., Inc. PROPRIETARY DATA NOTICE This document, as well as all reports, illustrations, data, information, and other materials is the property of LG Electronics U.S.A., Inc.

Due to our policy of continuous product innovation, some specifications may change without notification.

© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp. 3 Introduction About LG Electronics, Inc. LG Electronics, Inc. is a global leader and technology innovator in consumer electronics, mobile communications, and home appliances, employing more than 213,000 people in more than 60 countries worldwide. With $136 billion (USD) revenue in 2011, LG Electronics, Inc. is ranked among Fortune 500’s list of largest companies. LG Electronics, Inc. comprises five business units— Home Entertainment, Mobile Communications, Air Conditioning, Business Solutions, and Home Appliance. LG is one of the world’s leading producers of flat panel televisions, audio and video products, mobile handsets, air conditioners, and washing machines. LG’s commercial air conditioning business unit was established in 1968 and has built its lineup of residential and commercial products to include VRF, Flex-Multi, duct-free split systems, packaged terminal air conditioners (PTACs), and room air conditioners. In 2011, the air conditioning and energy solutions business unit grew to include LED lighting and solar products. For more information, visit www.lg.com. Duct Free Split (DFS) Technology LG HVAC systems offer a range of solutions that are cost efficient, quiet and attractive. Duct-Free Split (DFS) systems are “split” into indoor and outdoor units, and provide a smart alternative to both central HVAC and window-mounted air conditioners. These inverter heat pump systems are available in a variety of configurations to suit different cooling and heating situations. Installation by a qualified HVAC contractor is safe and easy – little to no duct work or sheet metal is required. Inverter Systems LG Single Zone Inverter Wall Mount air-source systems offer the opportunity to minimize ductwork in the same configuration. The system offers zoning without the need for zone damper systems. The LG Single Zone Inverter Wall Mount system’s advanced controls provide exceptional building dehumidification and temperature control, and can rapidly adapt system operating parameters to the ever changing building load. The LG Single Zone Inverter Wall Mount system is easy to design, install, and maintain. The modular design allows occupants to control their environmental condition, providing individualized control of the set-point temperature and allowing oc- cupants to condition only the occupied zones. Quality Commitment LG is committed to the success of DFS projects. We provide industry leading technical support during installation and commissioning. LG offers a variety of classes designed for installers and servicers to ensure that every DFS system installation is completed successfully. Classes are conducted at LG’s training centers and in field locations at various times throughout the year and upon special request.

4 | INTRODUCTION

Single Zone High Efficiency, Standard and Extended Pipe Wall Mount Engineering Manual Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp. TABLE OF CONTENTS Architectural Appeal.............................................................................. 6 Product Features and Benefits ............................................................ 8 Unit Nomenclature ................................................................................. 9 General Data ...................................................................................10-17 Electrical Data ...................................................................................... 18 Outdoor Unit Dimensions ..............................................................19-21 Indoor Unit Dimensions .................................................................22-25 Outdoor Unit Acoustic Data................................................................ 26 Indoor Unit Acoustic Data..............................................................27-28 Refrigerant Flow Diagrams ............................................................29-32 Wiring Diagrams .............................................................................33-39 Accessories ....................................................................................40-42 Performance Data ...........................................................................43-52 Equipment Selection Procedure ...................................................54-56 Building Ventilation Design Guide ...............................................57-58 Placement Considerations ............................................................59-61 Refrigerant Piping Design .............................................................64-65 Installation & Layout Best Practices ............................................66-70 Electrical Connections ...................................................................71-72 Mechanical Specifications .................................................................. 74 Acronyms ............................................................................................. 75 TABLE OF SYMBOLS This symbol indicates a potentially hazardous situation which, if not avoided, may result in death, serious injury, property damage or equipment damage. This symbol indicates additional helpful information such as an explanation, a comment, or a clarification about the subject. This symbol indicates a recommendation or tip. Recommendations instruct the user to apply the suggested practice to ensure the best operating results in order to achieve the maximum benefit of the product. Tips contain practical information that may help the user solve a problem or describe actions that may save time.

6 | INTRODUCTION

Single Zone High Efficiency, Standard and Extended Pipe Wall Mount Engineering Manual Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp. Benefits of Single Zone Wall Mount Systems • Available from 9,000 - 33,000 Btu/h • Inverter technology • All season use - heat pump models for both cooling and heating capabilities • Operating range for outdoor units of 14°F to 118°F in cooling and -4°F to 75°F in heating • Operating range for indoor units of 64°F to 90°F in cooling and 60°F to 86°F in heating • Quiet operation inside and outside • Duct-free split system Convergence of Technological Innovation with Flexibility and Style Single Zone Inverter Wall Mount Systems Single zone wall mount duct free split (DFS) systems are among the industry’s best air- conditioning units. Choosing an LG single zone wall mount product provides a system designer an edge to engineer a system with individual control, and design flexibility with advanced controls. Single zone systems are available in a nominal capacity range of 3/4 to 2-3/4 tons. These are best suited for applications with zones that require heating or cooling, such as residential, and small business office buildings. Single zone wall mount outdoor and indoor units are available in 208–230V/60Hz/1Ph. Adaptable and Flexible Single zone wall mount duct-free split (DFS) systems allow cooling or heating for the entire residence or just a single room without the need for evasive ductwork. There is no tearing down of walls or altering the homes appearance. Long refrigerant piping lengths allow for extra design flex- ibility in indoor unit installation. These units may be used for a number of residential or commercial environments such as: • Older homes • New home construction • Office buildings • Restaurants • Hospitals / Medical facilities • Schools • Nursing homes • Retail establishments • Place of worship Inverter Technology Inverter variable-speed DFS systems are measurably quieter and consume less energy than conventional air conditioners. The inverter compressor ramps up or down to match the required room capacity and maintain the comfort level. When the selected temperature is reached, the inverter compressor operates at low speed to maintain that comfort level, thereby using less energy. ARCHITECTURAL APPEAL

“Product Features and Benefits” on page 8

“Unit Nomenclature” on page 9 “General Data” on page 10 “Electrical Data” on page 18 “Outdoor Unit Dimensions” on page 19 “Indoor Unit Dimensions” on page 22 “Acoustic Data” on page 26 “Refrigerant Flow Diagrams” on page 29 “Wiring Diagrams” on page 33 “Accessories” on page 40 PRODUCT DATA

8 | PRODUCT DATA

Single Zone High Efficiency, Standard and Extended Pipe Wall Mount Engineering Manual Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. Single Zone Systems Single zone systems are equipped with inverter components that offer superior load matching and long piping installation. The product works for optimizing power consumption in residential and small office buildings. Utilizing multiple indoor wall mount units each with custom temperature controls allow for precise temperature settings in each zone of the building. Single zone sys- tems allow flexibility in interior design and complement any decor. Low Sound Levels When outdoor units operate fully loaded,they have one of the quietest sound levels in the industry. Sound is almost undetectable dur- ing off-peak operation. To promote a quiet, comfortable environment, the single zone system indoor units operate at sound levels as low as 24 dB(A) (High Efficiency Single Zone) and outdoor units as low as 45 dB(A) at full load (High Efficiency Single Zone). LG customers often ask if the outdoor unit is running after commissioning is complete. All rotating components are soft-started by the controller using digitally controlled inverters, which reduce undesirable noise caused by fans and compressors cycling on and off. Comfort Control at Its Best Tight temperature control through precise load matching maximizes the time that the indoor units remove moisture. Unlike traditional air conditioning control systems, which use thermostatic controls to maintain room temperatures, LG Single Zone Inverter controls continuously adjust the indoor unit fan speed and refrigerant flow, indirectly pro- viding lower and more consistent humidity levels in the conditioned space. The longer the indoor coil temperature is below the dew-point of the room in conjunction with air movement across the coil, the space humid- ity level will vary little, compared to technolo- gies that cycle fans and compressors on and off multiple times per hour. The outdoor unit responds by varying the compressor speed and outdoor fan motors as needed to main- tain system operating pressure. As a result, the single zone systems deliver precise space temperature control. Inverter Driven The rotary (9k-12k Btu/h systems) and twin rotary (18k-36k Btu/h systems) compressors are optimized to maximize compressor ef- ficiency, which reduces power consumption and monthly utility bills. This latest inverter technology allows single zone system out- door units to vary the compressor motor shaft speed to deliver an appropriate amount of cooling to the indoor unit. Precise refriger- ant volume delivery translates into long periods with coil surface temperatures below dew point and minimizes compressor and fan component run time. Occupants remain comfortable while utility costs are reduced. Simplified Installation Cooling and heating applications that use single zone systems simplify and reduce the mechanical and control system design time. The designer no longer has to be concerned with interconnecting chilled and condenser water piping, air-distribution duct systems,matching and selecting chillers, towers,pumps, coils, fans, air handlers, or Variable Air Volume (VAV) boxes. Operating Range Single zone systems have a nominal capac- ity range of 3/4 to 2-3/4 tons (depending on outdoor/indoor units). Operating ranges for single zone systems: Cooling: 14°F DB to 118°F DB Heating: -4°F WB to 75°F WB Installing an optional Low Ambient Wind Baffle Kit will allow operation down to 0°F in cooling mode for all single zone systems. Compact Size Single zone outdoor units have the following footprints: Single Zone High Efficiency LSU091HSV3, LSU121HSV3 (WxHxD (in)) 30 5/16 x 21 1/2 x 11 5/16. LSU181HSV3, LSU240HSV3 (WxHxD (in)) 34-1/4 x 31-1/2 x 12-5/8. Single Zone Standard LSU307HV3, LSU360HV3 (WxHxD (in)) 34-1/4 x 31-1/2 x 12-5/8. Single Zone Extended Pipe LSU240HLV, LSU300HLV, LSU360HLV (WxHxD (in)) 34-1/4 x 31-1/2 x 12-5/8. Fin Design with Gold- Fin™ Coating All single zone outdoor units are provided with large surface coils made of copper tubes with louvered aluminum fins designed to maximize unit operating efficiency over a wide range of ambient conditions. Standard from the factory, every single zone outdoor unit coil fin surface is coated with LG’s exclusive GoldFin™ anti-corrosive coating designed to prevent natural surface corrosion of the aluminum fins. This main- tains heat transfer properties of the coil for an extended time. A hydrophilic coating is applied to the outdoor unit coil fin surface over the GoldFin coating. This coating enhances the develop- ment of heavier water droplets gathering on the fin surface. As a result, the droplets roll off the fin surfaces, delaying the point when frost forms on the coil surface during heating operation. This coating also makes it possible to easily clean the outdoor unit coil using a mild soap. Other Features • Inverter variable speed compressor • Jet Cool / Jet Heat • Dehumidifying mode • Chaos Wind • Auto restart • Auto operation • Self-cleaning indoor coil • Condensate sensor connection • Cooling only function • Precision load matching • Meets AHRI 210/240 PRODUCT FEATURES AND BENEFITS

PRODUCT DATA | 9

Product Data Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. Single Zone Indoor and Outdoor Units LS N 091 HSV 3 Indoor/Outdoor Product HV - Standard Wall Mount HSV - High Efficiency Wall Mount HLV - Extended Pipe 091 = 9,000 121 = 11,200 181 = 18,200 240 = 22,000 300/307 = 30,000 360 = 33,000 Type N = Indoor Wall Mount Unit U = Outdoor Heat Pump Unit Family LS = High Efficiency Wall Mount/ Standard Wall Mount 3 = Third Generation Nominal Capacity Generation UNIT NOMENCLATURE (Nominal cooling capacity in Btu/h)

10 | PRODUCT DATA

Single Zone High Efficiency, Standard and Extended Pipe Wall Mount Engineering Manual Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. GENERAL DATA Single Zone High Efficiency & Single Zone Standard System Pairing Table The following tables show the available outdoor and indoor units, along with the factory provided controllers. Table 1: Single Zone High Efficiency & Single Zone Standard System Pairing Table Outdoor Unit Model Indoor Unit Model Controller LSU091HSV3 LSU121HSV3 LSN091HSV3 LSN121HSV3 AKB73855712 LSU181HSV3 LSN181HSV3 AKB73855712 LSU240HSV3 LSN240HSV3 AKB73855713 LSU307HV3 LSU360HV3 LSN307HV3 LSN360HV3 AKB73855713

PRODUCT DATA | 11

Product Data Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. GENERAL DATA Single Zone Extended Pipe System Pairing Table Table 2: Single Zone Extended Pipe System Pairing Table Outdoor Unit Model Indoor Unit Model Controller LSU240HLV LSU300HLV LSU360HLV LSN240HLV LSN300HLV LSN360HLV AKB74055401

12 | PRODUCT DATA

Single Zone High Efficiency, Standard and Extended Pipe Wall Mount Engineering Manual Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. Type Single Zone High Efficiency Units System Model Number (IDU/ODU) LS091HSV3 (LSN091HSV3/ LSU091HSV3) LS121HSV3 (LSN121HSV3/ LSU121HSV3) LS181HSV3 (LSN181HSV3/ LSU181HSV3) LS240HSV3 (LSN240HSV3/ LSU240HSV3) Nominal Cooling Capacity (Btu/h) 9,000 11,200 18,200 22,000 Cooling Power Input1 (kW) 0.67 0.89 1.4 1.7 Nominal Heating Capacity (Btu/h)1 10,800 13,300 22,000 27,600 Heating Power Input1 (kW) 0.70 1.0 1.7 2.3 Cooling COP 3.90 3.66 3.69 3.66 EER 13.3 12.5 12.6 12.5 SEER 21.5 21.5 20.5 20.0 HSPF 11.0 11.0 9.7 10.2 Power Supply (V/Hz/Ø) 208-230/60/1 Outdoor Unit Operating Range2 Cooling (°F DB) 14-118 Heating (°F WB) -4-75 Indoor Unit Operating Range2 Cooling (°F) 64-90 Heating (°F) 60-86 Unit Data Refrigerant Type3 R410A Refrigerant Control EEV IDU Sound Pressure4 dB(A) (H/M/L) 38/33/24 39/33/24 45/40/35 46/43/39 ODU Sound Pressure4 dB(A) 45 45 53 54 Power/Communication Cable5 (No. x AWG) 4 x 18 IDU Net/Shipping Weight (lbs) 23/28 23/28 32/41 36/42 ODU Net/Shipping Weight (lbs) 75/79 75/79 123/131 128/137 Compressor Compressor Type (Qty) Rotary (1) Rotary (1) Twin Rotary (1) Twin Rotary (1) Fan IDU Type (Qty) Cross Flow (1) ODU Type (Qty) Propeller (1) Motor/Drive Brushless Digitally Controlled/Direct Airflow Rate IDU Max/H/M/L (CFM) 388/335/272/212 423/353/272/212 735/622/509/399 883/742/629/424 ODU Max (CFM) 1,165 1,165 2,119 2,119 Table 3: Single Zone High Efficiency Unit Specifications GENERAL DATA Single Zone High Efficiency Unit Specifications EEV: Electronic Expansion Valve IDU: Indoor Unit ODU: Outdoor Unit 1Power Input is rated at high speed. 2Low Ambient Wind Baffle Kit allows operation down to 0°F in cooling mode. 3Take appropriate actions at the end of HVAC equipment life to recover, recycle, reclaim or destroy R410A refrigerant according to applicable regulations (40 CFR Part 82, Subpart F) under section 608 of CAA. 4Sound Pressure levels are tested in an anechoic chamber under ISO Standard 1996. 5All power/communication cables to be minimum 18 AWG, 4-conductor, stranded, shielded and must comply with applicable and national code. Power wiring is field supplied and must comply with the applicable local and national codes This unit comes with a dry helium charge. This data is rated 0 ft above sea level with 24.6 of refrigerant line per indoor unit and a 0 ft level difference outdoor and indoor units. Cooling capacity rating obtained with air entering the indoor unit at 80ºF dry bulb (DB) and 67ºF wet bulb (WB) and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB). Heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and 59ºF wet bulb (WB) and outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet bulb (WB).

PRODUCT DATA | 13

Product Data Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. GENERAL DATA Single Zone High Efficiency Unit Specifications Type Single Zone High Efficiency Units System Model Number (IDU/ODU) LS091HSV3 (LSN091HSV3/ LSU091HSV3) LS121HSV3 (LSN121HSV3/ LSU121HSV3) LS181HSV3 (LSN181HSV3/ LSU181HSV3) LS240HSV3 (LSN240HSV3/ LSU240HSV3) Piping Liquid Line (in, OD) 1/4 1/4 3/8 3/8 Vapor Line (in, OD) 3/8 3/8 5/8 5/8 Condensation Line (OD, ID) 27/32, 5/8 27/32, 5/8 27/32, 5/8 27/32, 5/8 Additional Refrigerant Charge (oz/ft) 0.22 0.22 0.38 0.38 Max Pipe Length6 (ft) 65.6 65.6 98.4 98.4 Piping Length6 (no add’l refrigerant, ft) 41.0 41.0 24.6 24.6 Max Elevation Difference (ft) 32.8 32.8 49.2 49.2 Table 4: Single Zone High Efficiency Unit Specifications Continued EEV: Electronic Expansion Valve IDU: Indoor Unit ODU: Outdoor Unit 6Piping lengths are equivalent. Power wiring is field supplied and must comply with the applicable local and national codes This unit comes with a dry helium charge. This data is rated 0 ft above sea level with 24.6 of refrigerant line per indoor unit and a 0 ft level difference outdoor and indoor units. Cooling capacity rating obtained with air entering the indoor unit at 80ºF dry bulb (DB) and 67ºF wet bulb (WB) and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB). Heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and 59ºF wet bulb (WB) and outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet bulb (WB).

14 | PRODUCT DATA

Single Zone High Efficiency, Standard and Extended Pipe Wall Mount Engineering Manual Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. Table 5: Single Zone Standard Unit Specifications Type Single Zone Standard Units System Model Number (IDU/ODU) LS307HV3 (LSN307HV3/LSU307HV3) LS360HV3 (LSN360HV3/LSU360HV3) Nominal Cooling Capacity (Btu/h) 30,000 33,000 Cooling Power Input1 (kW) 3.0 4.0 Nominal Heating Capacity (Btu/h)1 32,000 35,200 Heating Power Input1 (kW) 3.1 3.8 Cooling COP 2.93 2.40 EER 10.0 8.2 SEER 18.0 16.1 HSPF 9.5 9.9 Power Supply (V/Hz/Ø) 208-230/60/1 208-230/60/1 Outdoor Unit Operating Range Cooling (°F DB) 14-118 14-118 Heating (°F WB) -4-75 -4-75 Indoor Unit Operating Range Cooling (°F) 64-90 64-90 Heating (°F) 60-86 60-86 Unit Data Refrigerant Type2 R410A R410A Refrigerant Control EEV EEV IDU Sound Pressure3 dB(A) (H/M/L) 49/44/39 49/44/39 ODU Sound Pressure3 dB(A) 55 55 Power/Communication Cable4 (No. x AWG) 4 x 18 4 x 18 IDU Net/Shipping Weight (lbs) 36/42 36/42 ODU Net/Shipping Weight (lbs) 128/137 128/137 Compressor Compressor Type (Qty) Twin Rotary (1) Twin Rotary (1) Fan IDU Type (Qty) Cross Flow Cross Flow ODU Type (Qty) Propeller Propeller Motor/Drive Brushless Digitally Controlled/Direct Airflow Rate IDU Max/H/M/L (CFM) 883/770/629/424 883/795/629/424 ODU Max (CFM) 2,119 2,119 EEV: Electronic Expansion Valve IDU: Indoor Unit ODU: Outdoor Unit 1Power Input is rated at high speed. 2Take appropriate actions at the end of HVAC equipment life to recover, recycle, reclaim or destroy R410A refrigerant according to applicable regulations (40 CFR Part 82, Subpart F) under section 608 of CAA. 3Sound Pressure levels are tested in an anechoic chamber under ISO Standard 1996. 4All power/communication cables to be minimum 18 AWG, 4-conductor, stranded, shielded and must comply with applicable and national code. Power wiring is field supplied and must comply with the applicable local and national codes This unit comes with a dry helium charge. This data is rated 0 ft above sea level with 24.6 of refrigerant line per indoor unit and a 0 ft level difference outdoor and indoor units. Cooling capacity rating obtained with air entering the indoor unit at 80ºF dry bulb (DB) and 67ºF wet bulb (WB) and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB). Heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and 59ºF wet bulb (WB) and outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet bulb (WB). GENERAL DATA Single Zone Standard Specifications

PRODUCT DATA | 15

Product Data Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. Type Single Zone Standard Units System Model Number (IDU/ODU) LS307HV3 (LSN307HV3/LSU307HV3) LS360HV3 (LSN360HV3/LSU360HV3) Piping Liquid Line (in, OD) 3/8 3/8 Vapor Line (in, OD) 5/8 5/8 Condensation Line (OD/ID) 27/32, 5/8 27/32, 5/8 Additional Refrigerant Charge (oz/ft) 0.38 0.38 Max Pipe Length5 (ft) 98.4 98.4 Piping Length5 (no add’l refrigerant, ft) 24.6 24.6 Max Elevation Difference (ft) 49.2 49.2 Table 6: Single Zone Standard Unit Specifications Continued EEV: Electronic Expansion Valve IDU: Indoor Unit ODU: Outdoor Unit 5Piping lengths are equivalent. Power wiring is field supplied and must comply with the applicable local and national codes This unit comes with a dry helium charge. This data is rated 0 ft above sea level with 24.6 of refrigerant line per indoor unit and a 0 ft level difference outdoor and indoor units. Cooling capacity rating obtained with air entering the indoor unit at 80ºF dry bulb (DB) and 67ºF wet bulb (WB) and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB). Heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and 59ºF wet bulb (WB) and outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet bulb (WB). GENERAL DATA Single Zone Standard Specifications

16 | PRODUCT DATA

Single Zone High Efficiency, Standard and Extended Pipe Wall Mount Engineering Manual Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. GENERAL DATA Single Zone Extended Pipe Unit Specifications Type Single Zone Extended Pipe Units System Model Number (IDU/ODU) LS240HLV (LSN240HLV/ LSU240HLV) LS300HLV (LSN300HLV/ LSU300HLV) LS360HLV (LSN360HLV/ LSU360HLV) Nominal Cooling Capacity (Btu/h) 22,000 30,000 33,000 Cooling Power Input1 (kW) 1.7 3.0 4.0 Nominal Heating Capacity (Btu/h)1 27,000 32,000 35,200 Heating Power Input1 (kW) 2.3 3.1 3.8 Cooling COP 3.66 2.93 2.40 EER 12.5 10.0 8.2 SEER 21.0 18.5 16.5 HSPF 11 10 10 Power Supply (V/Hz/Ø) 208-230/60/1 Outdoor Unit Operating Range Cooling (°F DB) 14-118 Heating (°F WB) -4-75 Indoor Unit Operating Range Cooling (°F) 64-90 Heating (°F) 60-86 Unit Data Refrigerant Type2 R410A Refrigerant Control EEV IDU Sound Pressure3 dB(A) (H/M/L) 49/44/40 49/44/40 49/44/40 ODU Sound Pressure3 dB(A) 55 55 55 Power/Communication Cable4 (No. x AWG) 4 x 18 IDU Net/Shipping Weight (lbs) 40/46 40/46 40/46 ODU Net/Shipping Weight (lbs) 125/133 125/133 125/133 Compressor Compressor Type (Qty) Twin Rotary (1) Twin Rotary (1) Twin Rotary (1) Fan IDU Type (Qty) Cross Flow ODU Type (Qty) Propeller Motor/Drive Brushless Digitally Controlled/Direct Airflow Rate IDU Max/H/M/L (CFM) 848/706/530/459 848/706/530/459 848/706/530/459 ODU Max (CFM) 2,119 2,119 2,119 Table 7: Single Zone Extended Pipe Unit Specifications EEV: Electronic Expansion Valve IDU: Indoor Unit ODU: Outdoor Unit 1Power Input is rated at high speed. 2Take appropriate actions at the end of HVAC equipment life to recover, recycle, reclaim or destroy R410A refrigerant according to applicable regulations (40 CFR Part 82, Subpart F) under section 608 of CAA. 3Sound Pressure levels are tested in an anechoic chamber under ISO Standard 1996. 4All power/communication cables to be minimum 18 AWG, 4-conductor, stranded, shielded and must comply with applicable and national code. Power wiring is field supplied and must comply with the applicable local and national codes This unit comes with a dry helium charge. This data is rated 0 ft above sea level with 24.6 of refrigerant line per indoor unit and a 0 ft level difference outdoor and indoor units. Cooling capacity rating obtained with air entering the indoor unit at 80ºF dry bulb (DB) and 67ºF wet bulb (WB) and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB). Heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and 59ºF wet bulb (WB) and outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet bulb (WB).

PRODUCT DATA | 17

Product Data Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. GENERAL DATA Single Zone Extended Pipe Unit Specifications Type Single ZoneExtended Pipe Units System Model Number (IDU/ODU) LS240HLV (LSN240HLV/ LSU240HLV) LS300HLV (LSN300HLV/ LSU300HLV) LS360HLV (LSN360HLV/ LSU360HLV) Piping Liquid Line (in, OD) 3/8 3/8 3/8 Vapor Line (in, OD) 5/8 5/8 5/8 Condensation Line (OD, ID) 27/32, 5/8 27/32, 5/8 27/32, 5/8 Additional Refrigerant Charge (oz/ft) 0.38 0.38 0.38 Max Pipe Length5 (ft) 164 164 164 Piping Length5 (no add’l refrigerant, ft) 24.6 24.6 24.6 Max Elevation Difference (ft) 98.4 98.4 98.4 Table 8: Single Zone Extended Pipe Unit Specifications Continued EEV: Electronic Expansion Valve IDU: Indoor Unit ODU: Outdoor Unit 5Piping lengths are equivalent. Power wiring is field supplied and must comply with the applicable local and national codes This unit comes with a dry helium charge. This data is rated 0 ft above sea level with 24.6 of refrigerant line per indoor unit and a 0 ft level difference outdoor and indoor units. Cooling capacity rating obtained with air entering the indoor unit at 80ºF dry bulb (DB) and 67ºF wet bulb (WB) and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB). Heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and 59ºF wet bulb (WB) and outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet bulb (WB).

18 | PRODUCT DATA

Single Zone High Efficiency, Standard and Extended Pipe Wall Mount Engineering Manual Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. ELECTRICAL DATA Model Number Nom. Tons Compressor Qty Compressor (A) Cool/Heat Fan Qty ODU Fan (A) MCA (A) MOP (A) LSU091HSV3 3/4 1 8.7/8.7 1 0.40 10 15 LSU121HSV3 1 1 8.7/8.7 1 0.40 10 15 LSU181HSV3 1-1/2 1 15.4/15.4 1 0.25 19 25 LSU240HSV3 1-3/4 1 15.4/15.4 1 0.25 19 25 Table 9: Single Zone High Efficiency Unit Electrical Data Model Number Nom. Tons Compressor Qty Compressor (A) Cool/Heat Fan Qty ODU Fan (A) MCA (A) MOP (A) LSU307HV3 2-1/2 1 15.4/15.4 1 0.25 19 25 LSU360HV3 2-3/4 1 15.4/15.4 1 0.25 19 25 Table 10: Single Zone Standard Unit Electrical Data Model Number Nom. Tons Compressor Qty Compressor (A) Cool/Heat Fan Qty ODU Fan (A) MCA (A) MOP (A) LSU240HLV 1-3/4 1 17.3/17.3 1 0.25 23 35 LSU300HLV 2-1/2 1 17.3/17.3 1 0.25 23 35 LSU360HLV 2-3/4 1 17.3/17.3 1 0.25 23 35 Table 11: Single Zone Extended Pipe Unit Electrical Data

PRODUCT DATA | 19

Product Data Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. OUTDOOR UNIT DIMENSIONS LSU091HSV3, LSU121HSV3 30-5/16 22 4-3/16 13-7/8 6-1/8 2-1/8 10-7/8 1 20-7/8 21-1/2 10-1/2 2-13/16 8-1/8 4 3 2 5 11-5/16 Ø18-5/16 Unit: inch Return Air Grille

20 | PRODUCT DATA

Single Zone High Efficiency, Standard and Extended Pipe Wall Mount Engineering Manual Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. OUTDOOR UNIT DIMENSIONS LSU181HSV3, LSU240HSV3, LSU307HV3, LSU360HV3 34-1/4 21-1/2 12-5/8 14-3/16 6-5/16 2-3/16 13-1/8 12-5/8 31-1/2 30-13/16 15-3/8 3-1/8 2 Ø20-7/8 R emarks Pa tr Name m N .o etI 1 Return Air Grille 2 3 4 5 6 Unit: inch

PRODUCT DATA | 21

Product Data Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. OUTDOOR UNIT DIMENSIONS LSU240HLV, LSU300HLV, LSU360HLV Item No. Part Name Remarks 1 Air discharge grille 2 3 4 5 6 34-1/4 21-1/2 12 -5/8 14- 3/16 6-5/16 2- 3/16 13- 1/8 12- 5/8 31- 1/2 30-27/32 15- 7/16 3-5/32 1 -31/32 Ø 20-29/32 Unit: inch

22 | PRODUCT DATA

Single Zone High Efficiency, Standard and Extended Pipe Wall Mount Engineering Manual Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. INDOOR UNIT DIMENSIONS LSN091HSV3, LSN121HSV3 Ø2-3/4 5-3/16 3-11/16 Right rear piping Left rear piping Installation Plate Place a level on raised tab Unit Outline 8-1/2 6-29/32 7-13/32 1 8-1/4 3 34-13/16 8-1/4 11-1/4 2 1 4 2-5/16 6-5/16 5 29/32 Unit: inch Ø2-3/4 7-13/32 1 Return Air Grille

PRODUCT DATA | 23

Product Data Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. INDOOR UNIT DIMENSIONS LSN181HSV3 9 -11/16 40-9/16 12-13/16 9-11/16 Ø 2-13/16 Ø 2 -13/16 2-11/16 2-13/16 Right rear piping Left rear piping Installation Plate Measuring Tape Measuring Tape Hanger Place a level on raised tab Unit Outline 8 -3/32 4 -3/32 18 -3/32 22-13/32 4 Unit:inch

24 | PRODUCT DATA

Single Zone High Efficiency, Standard and Extended Pipe Wall Mount Engineering Manual Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. INDOOR UNIT DIMENSIONS LSN240HSV3, LSN307HV3, LSN360HV3

PRODUCT DATA | 25

Product Data Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. INDOOR UNIT DIMENSIONS LSN240HLV, LSN300HLV, LSN360HLV 10 -7/16 46-7/8 40-9/16 13- 5/8 2- 17/32 2-11/32 3 2 1 4 33 -25/32 6 9/16 1- 11/16 17- 7/32 Ø -2 17/32 4 -23/32 1- 11/16 Ø 2- 17/32 4 -23/32 6 -9/16 Unit: inch Remarks Part Name Item No.

26 | PRODUCT DATA

Single Zone High Efficiency, Standard and Extended Pipe Wall Mount Engineering Manual Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. OUTDOOR UNIT ACOUSTIC DATA Model H LSU091HSV3 45 LSU121HSV3 45 LSU181HSV3 53 LSU240HSV3 54 LSU307HV3 55 LSU360HV3 55 LSU240HLV 55 LSU300HLV 55 LSU360HLV 55 Table 12: Outdoor Unit Acoustic Data Figure 1: Outdoor Unit Sound Levels 3.28 ft Center of Outdoor Unit Octave Band Center Frequency (Hz) 10 20 30 40 50 60 70 80 10 20 30 40 50 60 70 80 63 125 250 500 1000 2000 4000 8000 Octave Band Center Frequency (Hz) 63 125 250 500 1000 2000 4000 8000 NC-15 NC-20 NC-25 NC-30 NC-35 NC-40 NC-45 NC-50 NC-55 NC-60 NC-65 Approximate Hearing Threshold 10 20 30 40 50 60 70 80 63 125 250 500 1000 2000 4000 8000 Octave Band Center Frequency (Hz) NC-15 NC-20 NC-25 NC-30 NC-35 NC-40 NC-45 NC-50 NC-55 NC-60 NC-65 Approximate Hearing Threshold NC-15 NC-20 NC-25 NC-30 NC-35 NC-40 NC-45 NC-50 NC-55 NC-60 NC-65 Approximate Hearing Threshold Octave Band Center Frequency (Hz) 10 20 30 40 50 60 70 80 63 125 250 500 1000 2000 4000 8000 Approximate Hearing Threshold NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 NC-15 Octave Band Center Frequency (Hz) Octave Band Sound Pressure Level (0dB = 20μPa) 10 20 30 40 50 60 70 80 63 125 250 500 1000 2000 4000 8000 NC-15 NC-20 NC-25 NC-30 NC-35 NC-40 NC-45 NC-50 NC-55 NC-60 NC-65 Approximate Hearing Threshold Figure 2: LSU091HSV3 Figure 3: LSU121HSV3 Figure 4: LSU181HSV3 Figure 5: LSU240HSV3, LSU307HV3, LSU360HV3 Figure 6: LSU240HLV, LSU300HLV, LSU360HLV

PRODUCT DATA | 27

Product Data Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. INDOOR UNIT ACOUSTIC DATA Figure 7: Indoor Unit Sound Levels 2.62 ft 3.28 ft Microphone Model H M L LSN091HSV3 38 33 24 LSN121HSV3 39 33 24 LSN181HSV3 45 40 35 LSN240HSV3 46 43 39 LSN307HV3 49 44 39 LSN360HV3 49 44 39 LSN240HLV 49 44 40 LSN300HLV 49 44 40 LSN360HLV 49 44 40 Table 13: Indoor Unit Acoustic Data 10 20 30 40 50 60 70 80 63 125 250 500 1000 2000 4000 8000 Octave Band Center Frequency (Hz) NC-15 NC-20 NC-25 NC-30 NC-35 NC-40 NC-45 NC-50 NC-55 NC-60 NC-65 Approximate Hearing Threshold 10 20 30 40 50 60 70 80 63 125 250 500 1000 2000 4000 8000 Octave Band Center Frequency (Hz) NC-15 NC-20 NC-25 NC-30 NC-35 NC-40 NC-45 NC-50 NC-55 NC-60 NC-65 Approximate Hearing Threshold Octave Band Center Frequency (Hz) 10 20 30 40 50 60 70 80 63 125 250 500 1000 2000 4000 8000 NC-15 NC-20 NC-25 NC-30 NC-35 NC-40 NC-45 NC-50 NC-55 NC-60 NC-65 Approximate Hearing Threshold 10 20 30 40 50 60 70 80 63 125 250 500 1000 2000 4000 8000 Octave Band Center Frequency (Hz) NC-15 NC-20 NC-25 NC-30 NC-35 NC-40 NC-45 NC-50 NC-55 NC-60 NC-65 Approximate Hearing Threshold 10 20 30 40 50 60 70 80 63 125 250 500 1000 2000 4000 8000 NC-15 NC-20 NC-25 NC-30 NC-35 NC-40 NC-45 NC-50 NC-55 NC-60 NC-65 Approximate Hearing Threshold 10 20 30 40 50 60 70 80 63 125 250 500 1000 2000 4000 8000 Approximate Hearing Threshold NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 NC-20 NC-15 Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Figure 8: LSN091HSV3 Figure 9: LSN121HSV3 Figure 10: LSN181HSV3 Figure 11: LSN240HSV3 Figure 12: LSN307HSV3 Figure 13: LSN360HSV3

28 | PRODUCT DATA

Single Zone High Efficiency, Standard and Extended Pipe Wall Mount Engineering Manual Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. INDOOR UNIT ACOUSTIC DATA Octave Band Center Frequency (Hz) Octave Band Sound Pressure Level (0dB = 20μPa) 10 20 30 40 50 60 70 80 63 125 250 500 1000 2000 4000 8000 NC-15 NC-20 NC-25 NC-30 NC-35 NC-40 NC-45 NC-50 NC-55 NC-60 NC-65 Approximate Hearing Threshold Octave Band Center Frequency (Hz) Octave Band Sound Pressure Level (0dB = 20μPa) 10 20 30 40 50 60 70 80 63 125 250 500 1000 2000 4000 8000 NC-15 NC-20 NC-25 NC-30 NC-35 NC-40 NC-45 NC-50 NC-55 NC-60 NC-65 Approximate Hearing Threshold Octave Band Center Frequency (Hz) Octave Band Sound Pressure Level (0dB = 20μPa) 10 20 30 40 50 60 70 80 63 125 250 500 1000 2000 4000 8000 NC-15 NC-20 NC-25 NC-30 NC-35 NC-40 NC-45 NC-50 NC-55 NC-60 NC-65 Approximate Hearing Threshold Figure 14: LSN240HLV Figure 15: LSN300HLV Figure 16: LSN360HLV

PRODUCT DATA | 29

Product Data Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. LSU/LSN091HSV3, LSU/LSN121HSV3 REFRIGERANT FLOW DIAGRAMS LOC. Description PCB Connector Th1 Suction air temperature thermistor CN-TH1 (Indoor) Th2 Water level sensor (optional) CN-TH2 (Indoor) Th3 Evaporating middle temperature thermistor CN-TH3 (Indoor) Th4 Discharge pipe temperature thermistor CN-TH2 (Outdoor) Th5 Condensing temperature thermistor CN-TH1 (Outdoor) Th6 Outdoor air temperature thermistor tin Outdoo r U tin ndoo r U I Heat Exchanger (Evaporator) Heat Exchanger (Condenser) Compressor Accumulator Gas Side 3-Way Valve 2-Way Valve Liquid Side Cooling Heating Reversing Valve EEV Th1 Th5 Th2 Th6 Th3 Th4 EEV : Electronic Expansion Valve

30 | PRODUCT DATA

Single Zone High Efficiency, Standard and Extended Pipe Wall Mount Engineering Manual Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. LSU/LSN181HSV3 REFRIGERANT FLOW DIAGRAMS tin Outdoo r U tin ndoo r U I Heat Exchanger (Evaporator) Heat Exchanger (Condenser) Compressor Accumulator Gas Side 3-Way Valve 2-Way Valve Liquid Side Cooling Heating Reversing Valve EEV Th1 Th5 Th2 Th6 Th3 Th4 EEV : Electronic Expansion Valve LOC. Description PCB Connector Th1 Suction air temperature thermistor CN-TH1 (Indoor) Th2 Water level sensor (optional) Th3 Evaporating outlet temperature thermistor + water level sensor CN-TH2 (Indoor) Th4 Evaporating middle temperature thermistor CN-TH3 (Indoor) Th5 Discharge pipe temperature thermistor CN-TH3 (Outdoor) Th6 Suction pipe temperature thermistor Th7 Condensing temperature thermistor CN-TH2 (Outdoor) Th8 Outdoor air temperature thermistor Th9 Condensing middle temperature thermistor CN-TH4 (Outdoor)

PRODUCT DATA | 31

Product Data Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. LSU/LSN240HSV3, LSU/LSN307HV3, LSU/LSN360HV3 REFRIGERANT FLOW DIAGRAMS tin Outdoo r U tin ndoo r U I Heat Exchanger (Evaporator) Heat Exchanger (Condenser) Compressor Accumulator Gas Side 3-Way Valve 2-Way Valve Liquid Side Cooling Heating Reversing Valve EEV Th1 Th2 Th7 Th3 Th8 Th9 Th6 Th4 Th5 LOC. Description PCB Connector Th1 Suction air temperature thermistor CN-TH1 (Indoor) Th2 Water level sensor (optional) Th3 Evaporating outlet temperature thermistor + water level sensor CN-TH2 (Indoor) Th4 Evaporating middle temperature thermistor CN-TH3 (Indoor) Th5 Discharge pipe temperature thermistor CN-TH3 (Outdoor) Th6 Suction pipe temperature thermistor Th7 Condensing temperature thermistor CN-TH2 (Outdoor) Th8 Outdoor air temperature thermistor Th9 Condensing middle temperature thermistor CN-TH4 (Outdoor)

32 | PRODUCT DATA

Single Zone High Efficiency, Standard and Extended Pipe Wall Mount Engineering Manual Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. REFRIGERANT FLOW DIAGRAMS LSU/LSN240HLV, LSU/LSN300HLV, LSU/LSN360HLV Indoor Unit Outdoor Unit Heat Exchanger (Evaporator) Heat Exchanger (Condenser) Compressor Accumulator Gas Side 3-Way Valve 2-Way Valve Liquid Side Cooling Heating Reversing Valve EEV Th1 Th2 Th4 Th5 Th3 LOC. Description PCB Connector Th1 Suction air temperature thermistor CN-TH1 (Indoor) Th2 Evaporating middle temperature thermistor CN-TH3 (Indoor) Th3 Discharge pipe temperature thermistor CN-TH3 (Outdoor) Th4 Condensing temperature thermistor CN-TH2 (Outdoor) Th5 Outdoor air temperature thermistor

PRODUCT DATA | 33

Product Data Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. LSN091HSV3, LSN121HSV3 WIRING DIAGRAMS

34 | PRODUCT DATA

Single Zone High Efficiency, Standard and Extended Pipe Wall Mount Engineering Manual Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. LSN181HSV3 WIRING DIAGRAMS

PRODUCT DATA | 35

Product Data Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. LSN240HSV3, LSN307HV3, LSN360HV3 WIRING DIAGRAMS

36 | PRODUCT DATA

Single Zone High Efficiency, Standard and Extended Pipe Wall Mount Engineering Manual Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. LSN240HLV, LSN300HLV, LSN360HLV WIRING DIAGRAMS

PRODUCT DATA | 37

Product Data Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. LSU091HSV3, LSU121HSV3 WIRING DIAGRAMS

38 | PRODUCT DATA

Single Zone High Efficiency, Standard and Extended Pipe Wall Mount Engineering Manual Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. LSU181HSV3, LSU240HSV3, LSU307HV3, LSU360HV3 WIRING DIAGRAMS

PRODUCT DATA | 39

Product Data Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. LSU240HLV, LSU300HLV, LSU360HLV WIRING DIAGRAMS

40 | PRODUCT DATA

Single Zone High Efficiency, Standard and Extended Pipe Wall Mount Engineering Manual Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. ACCESSORIES Table 14: Optional Zone Controllers Before specifying or placing an order, refer to the V-Net Network Solution Engineering Product Data Book and review the detailed technical data provided to fully understand the capabilities and limitations of these devices. Zone Controller Name Model No. Case Color Max Wire Length (ft) Description Simple Controller with mode selection PQRCVCL0Q Black 164 Allows control of indoor unit on/off, operation mode, fan speed, and temperature setpoint for up to 16 indoor units. PQRCVCL0QW White Simple Controller without mode selection PQRCHCA0Q Black 164 Allows control of indoor unit on/off, fan speed, and temperature setpoint for up to 16 indoor units. PQRCHCA0QW White LG Programmable Thermostat PREMTB10U White 164 Allows control of indoor unit on/off, operation mode, occupied and unoccupied temperature setpoints, fan speed, and airflow direction for up to 16 indoor units. Programmable schedule with 5 events per day with control of occupied/unoccupied, on/off, mode, setpoints and fan speed. Advanced functions include two setpoint autochangoever, minimum difference between setpoints, setback and timed override. Table 15: Summary Data—Zone Controller Communication Cables Communication Cable Name Model No. Wire Length (ft) Description Wired Remote/Group Control Extension Cable PZCWRC1 32 Increases the distance between a remote controller and an indoor unit or between indoor units in a control group. Before specifying or placing an order, refer to the V-Net Network Solution Engineering Product Data Book and review the detailed technical data provided to fully understand the capabilities and limitations of these devices.

PRODUCT DATA | 41

Product Data Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. ACCESSORIES Table 16: Summary Data—Speciality Application Devices Speciality Application Device Name Model No. Connect to Application Binary Signals Input/ Output Description Dry Contact Unit 24 VAC PQDSB1 Indoor Unit On/Off, Run Status, Error Status 1/2 Enables the indoor unit to be controlled and monitored by third party controls using binary inputs and outputs. Dry Contact Unit for Communication PQDSBCGCD0 On/Off, Mode, Controller Lock, Power Save,Run Status, Error Status 2/2 Dry Contact Unit for Thermostat PQDSBNGCM1 On/Off, Thermo On/ Off, Mode,Fan Speed, Run Status, Error Status --- Enables the indoor unit to be controlled and monitored by a third party thermostat or controller. PI-485 V-net Control Integration Board1 PMNFP14A0 Outdoor Unit --- --- Control integration to LG V-net controls (AC Smart Premium, ACP, BACnet, LonWorks, etc.) Digital Output (DO) Kit PQNFP00T0 Comm Bus On/Off 0/1 One 25 amp DPST normally open relay. Used with central controller to control third party device manually or by schedule. 1The PI-485 is only available for use with models 18,000 Btu/h and larger. Before specifying or placing an order, refer to the V-Net Network Solution Engineering Product Data Book and review the detailed technical data provided to fully understand the capabilities and limitations of these devices.

42 | PRODUCT DATA

Single Zone High Efficiency, Standard and Extended Pipe Wall Mount Engineering Manual Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. ACCESSORIES • Actual inverter compressor speed • Target inverter compressor speed • Actual outdoor fan speed • Target outdoor unit fan speed • Actual superheat • Inverter compressor current value • Outdoor air temperature • Actual high pressure/saturation temperature • Actual low pressure/saturation temperature • Suction temperature • Inverter compressor discharge temperature • Outdoor coil pipe temperature • Liquid line pipe temperature • Inverter compressor operation indicator light • Four-way reversing valve operation indicator light • Pressure graph showing actual low pres- sure and actual high pressure levels • Error code display • Operating mode indicator • Total number of connected indoor units (for multi zone systems) • Communication indicator lights • Unit error code • Indoor unit capacity • Indoor unit operating mode • Indoor unit fan speed • Indoor unit room temperature • Indoor unit inlet pipe temperature • Indoor unit outlet pipe temperature LG Monitoring View (LGMV) Diagnostic Software and Cable (PRCTSL1 and PRCTFE1) LGMV software allows the service technician or commissioning agent to connect a computer USB port to the outdoor unit main printed circuit board (PCB) using an accessory cable with- out the need for a separate interface device. The main screen for LGMV shall allow user to view the following real time data on one screen: Additional screens can be accessed by tabs on the main screen: 1. Cycleview: Graphic of internal components including: 2. Setting: Converts metric values to imperial values. 3. Making Data: Recording of real time data to a separate file created to be stored on the user’s computer. 4. Loading Data: Recorded data from a saved “.CSV” file can be loaded to create an LGMV session. 5. Electrical Data: The lower half of main screen is changed to show the following: • Compressors showing actual speeds • EEVs • IDUs • Low and high pressures • Temperature and pressure sensors • Four-way reversing valve • Outdoor fans showing status and speeds • Inverter compressor - Amps - Volts - Power Hz - Inverter control board fan Hz The software is available in a high version with all of the features listed above. The low version has all features as the high version without Target High Pressure and Target Low Pressure values shown on main screen. In lieu of connecting to the ODU, user has the option to connect to IDU with the use of a USB to RS-485 connector kit. When connected through IDU, user will not be able to record data. This software can be used to both commission new systems and troubleshoot existing systems. LGMV data can be recorded to a “.CSV” file and emailed to an LG representative to assist with diagnostic evaluations. Recommended Minimum PC Configuration: • CPU: Pentium® IV 1.6 GHz • Operating System: Windows® NT/2000/ XP/Vista • Main Memory: 256 MB • Hard Disk: 600 MB when operating • Web Browser: Internet Explorer® 5.0

44 | PRODUCT DATA

High Efficiency, Standard and Extended Pipe Wall Mount Engineering Manual Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp. Cooling Capacity PERFORMANCE DATA DB: Dry Bulb Temperature (°F) WB: Wet Bulb Temperature (°F) TC: Total Capacity (kBtu/h) SHC: Sensible Capacity (kBtu/h) PI: Power Input (kW) (includes compressor,indoor fan motor and outdoor fan motor) 1. All capacities are net, evaporator fan motor heat is deducted. 2. Grey shading indicates reference data. When operating the unit at this temperature, these values can be different by discontinuous operation. 3. Direct interpolation is permissable. Do not extrapolate. Nominal capacity as rated: 0 ft. above sea level with 25 ft. of refrigerant piping. 0 ft. level difference between outdoor and indoor units. Nominal cooling capacity rating obtained with air entering the indoor unit at 80ºF dry bulb (DB) and 67ºF wet bulb (WB), and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB). LSN/LSU091HSV3,LSN/LSU121HSV3,LSN/LSU181HSV3 Outdoor Air Temp. (°F DB) Indoor Air Temperature (°F DB/ °F WB) 64 / 53 68 / 57 72 / 61 77 / 64 80 / 67 86 / 72 90 / 75 TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 14 5.51 4.83 0.29 5.92 5.19 0.30 6.33 5.56 0.31 6.75 5.92 0.32 6.94 6.08 0.33 7.57 6.64 0.34 7.99 7.00 0.35 23 5.92 5.00 0.29 6.36 5.38 0.30 6.80 5.75 0.31 7.24 6.13 0.31 7.45 6.30 0.32 8.13 6.88 0.34 8.57 7.25 0.35 59 7.10 5.37 0.33 7.63 5.78 0.34 8.16 6.18 0.35 8.69 6.58 0.36 8.94 6.77 0.37 9.75 7.39 0.39 10.29 7.79 0.40 70 8.10 6.60 0.49 8.64 7.04 0.50 9.18 7.47 0.52 9.54 7.77 0.53 9.81 7.99 0.55 10.53 8.57 0.57 11.25 9.16 0.59 75 8.00 6.62 0.50 8.54 7.07 0.52 9.08 7.52 0.53 9.45 7.83 0.55 9.72 8.05 0.57 10.40 8.61 0.59 11.16 9.24 0.61 80 7.79 6.56 0.52 8.33 7.02 0.54 8.87 7.47 0.56 9.27 7.81 0.57 9.63 8.11 0.59 10.26 8.64 0.62 10.98 9.25 0.63 85 7.58 6.59 0.56 8.12 7.06 0.58 8.66 7.52 0.60 9.09 7.90 0.61 9.45 8.21 0.63 10.13 8.80 0.66 10.82 9.40 0.68 90 7.37 6.63 0.58 7.91 7.12 0.60 8.45 7.60 0.62 8.91 8.01 0.64 9.27 8.34 0.66 9.99 8.99 0.69 10.60 9.53 0.71 95 7.15 6.66 0.60 7.68 7.15 0.62 8.22 7.65 0.64 8.75 8.15 0.66 9.00 8.38 0.68 9.83 9.15 0.71 10.36 9.65 0.73 100 6.96 6.55 0.61 7.50 7.05 0.63 8.03 7.56 0.65 8.57 8.06 0.67 8.88 8.36 0.69 9.64 9.07 0.72 10.17 9.57 0.74 105 6.77 6.44 0.62 7.31 6.95 0.64 7.84 7.46 0.66 8.38 7.97 0.68 8.77 8.34 0.70 9.45 8.99 0.73 9.99 9.50 0.75 110 6.59 6.38 0.63 7.12 6.90 0.65 7.66 7.42 0.67 8.19 7.94 0.69 8.58 8.31 0.71 9.26 8.98 0.74 9.80 9.49 0.76 115 6.40 6.26 0.64 6.94 6.79 0.65 7.47 7.31 0.68 8.01 7.83 0.70 8.39 8.21 0.72 9.08 8.88 0.75 9.61 9.41 0.77 118 6.21 6.12 0.64 6.75 6.65 0.66 7.20 7.10 0.68 7.74 7.63 0.70 8.10 7.98 0.72 8.78 8.65 0.75 9.27 9.14 0.78 122 5.92 5.84 0.64 6.42 6.35 0.66 6.93 6.85 0.68 7.44 7.35 0.71 7.80 7.71 0.73 8.45 8.35 0.76 8.96 8.85 0.78 Table 17: LSN091HSV3/LSU091HSV3 Cooling Capacities Table 18: LSN121HSV3/LSU121HSV3 Cooling Capacities Outdoor Air Temp. (°F DB) Indoor Air Temperature (°F DB/ °F WB) 64 / 53 68 / 57 72 / 61 77 / 64 80 / 67 86 / 72 90 / 75 TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 14 6.86 6.01 0.38 7.37 6.46 0.39 7.88 6.91 0.40 8.40 7.36 0.42 8.63 7.57 0.43 9.42 8.26 0.45 9.94 8.71 0.46 23 7.36 6.23 0.38 7.91 6.69 0.39 8.46 7.16 0.40 9.01 7.63 0.41 9.27 7.84 0.43 10.12 8.56 0.44 10.67 9.03 0.46 59 8.83 6.69 0.44 9.49 7.19 0.45 10.16 7.69 0.46 10.82 8.19 0.48 11.12 8.42 0.49 12.14 9.19 0.51 12.80 9.69 0.53 70 10.08 8.21 0.64 10.75 8.75 0.66 11.42 9.30 0.68 11.87 9.67 0.70 12.21 9.94 0.73 13.10 10.67 0.76 14.00 11.40 0.78 75 9.95 8.24 0.66 10.63 8.80 0.68 11.30 9.36 0.70 11.76 9.74 0.72 12.10 10.02 0.75 12.94 10.71 0.78 13.89 11.50 0.80 80 9.69 8.16 0.69 10.36 8.73 0.71 11.04 9.30 0.73 11.54 9.72 0.76 11.98 10.10 0.78 12.77 10.76 0.81 13.66 11.51 0.84 85 9.43 8.20 0.74 10.10 8.78 0.76 10.77 9.36 0.78 11.31 9.83 0.81 11.76 10.22 0.83 12.60 10.95 0.87 13.46 11.70 0.89 90 9.17 8.25 0.77 9.84 8.85 0.79 10.51 9.46 0.82 11.09 9.97 0.84 11.54 10.38 0.87 12.43 11.18 0.90 13.19 11.87 0.93 95 8.90 8.28 0.79 9.56 8.90 0.82 10.23 9.52 0.84 10.89 10.14 0.87 11.20 10.43 0.90 12.23 11.38 0.93 12.89 12.00 0.96 100 8.66 8.15 0.81 9.33 8.78 0.83 10.00 9.40 0.86 10.66 10.03 0.88 11.05 10.40 0.91 11.99 11.29 0.95 12.66 11.91 0.98 105 8.43 8.02 0.82 9.10 8.65 0.85 9.76 9.28 0.87 10.43 9.92 0.90 10.91 10.37 0.93 11.76 11.18 0.96 12.43 11.82 0.99 110 8.20 7.94 0.83 8.86 8.59 0.85 9.53 9.23 0.88 10.20 9.88 0.91 10.68 10.35 0.94 11.53 11.17 0.97 12.19 11.82 1.00 115 7.96 7.79 0.84 8.63 8.45 0.86 9.30 9.10 0.89 9.96 9.75 0.92 10.44 10.22 0.95 11.30 11.05 0.98 11.96 11.70 1.01 118 7.73 7.62 0.84 8.40 8.28 0.87 8.96 8.83 0.90 9.63 9.49 0.93 10.08 9.94 0.95 10.92 10.76 0.99 11.54 11.37 1.02 122 7.36 7.27 0.85 7.99 7.90 0.87 8.62 8.52 0.90 9.25 9.14 0.93 9.71 9.59 0.96 10.51 10.39 1.00 11.14 11.01 1.03 Table 19: LSN181HSV3/LSU181HSV3 Cooling Capacities Outdoor Air Temp. (°F DB) Indoor Air Temperature (°F DB/ °F WB) 64 / 53 68 / 57 72 / 61 77 / 64 80 / 67 86 / 72 90 / 75 TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 14 11.14 9.77 0.61 11.98 10.50 0.63 12.81 11.23 0.65 13.64 11.97 0.67 14.03 12.30 0.69 15.31 13.43 0.72 16.15 14.16 0.74 23 11.96 10.12 0.61 12.86 10.88 0.63 13.75 11.64 0.65 14.65 12.39 0.67 15.06 12.74 0.69 16.44 13.91 0.72 17.34 14.67 0.74 59 14.35 10.87 0.70 15.43 11.68 0.73 16.50 12.50 0.75 17.58 13.31 0.77 18.07 13.68 0.80 19.73 14.94 0.83 20.80 15.75 0.85 70 16.38 13.34 1.04 17.47 14.23 1.07 18.56 15.12 1.10 19.29 15.71 1.14 19.84 16.15 1.17 21.29 17.34 1.22 22.75 18.52 1.26 75 16.17 13.39 1.07 17.27 14.30 1.10 18.36 15.21 1.14 19.11 15.83 1.17 19.66 16.28 1.21 21.02 17.41 1.25 22.57 18.69 1.29 80 15.75 13.27 1.11 16.84 14.19 1.15 17.93 15.11 1.18 18.75 15.79 1.22 19.47 16.41 1.26 20.75 17.48 1.31 22.20 18.70 1.35 85 15.33 13.32 1.19 16.42 14.27 1.23 17.51 15.22 1.27 18.38 15.97 1.31 19.11 16.61 1.35 20.48 17.79 1.40 21.87 19.01 1.44 90 14.91 13.41 1.24 16.00 14.39 1.28 17.08 15.37 1.32 18.02 16.21 1.36 18.75 16.86 1.40 20.20 18.17 1.46 21.44 19.28 1.50 95 14.46 13.46 1.28 15.54 14.47 1.32 16.62 15.48 1.36 17.70 16.48 1.40 18.20 16.95 1.45 19.87 18.50 1.50 20.95 19.51 1.55 100 14.08 13.25 1.30 15.16 14.26 1.34 16.24 15.28 1.38 17.32 16.30 1.43 17.96 16.90 1.47 19.49 18.34 1.53 20.57 19.36 1.58 105 13.70 13.03 1.32 14.78 14.06 1.36 15.86 15.09 1.41 16.95 16.12 1.45 17.73 16.86 1.50 19.11 18.17 1.56 20.19 19.20 1.60 110 13.32 12.91 1.34 14.40 13.96 1.38 15.49 15.00 1.42 16.57 16.05 1.47 17.35 16.81 1.51 18.73 18.15 1.57 19.82 19.20 1.62 115 12.94 12.66 1.35 14.02 13.72 1.39 15.11 14.78 1.44 16.19 15.84 1.48 16.97 16.61 1.53 18.35 17.96 1.59 19.44 19.02 1.64 118 12.56 12.38 1.36 13.65 13.45 1.41 14.56 14.35 1.45 15.65 15.43 1.49 16.38 16.14 1.54 17.75 17.49 1.60 18.75 18.48 1.65 122 11.96 11.82 1.37 12.99 12.83 1.41 14.01 13.84 1.46 15.04 14.86 1.50 15.78 15.59 1.55 17.09 16.88 1.61 18.11 17.89 1.66

PRODUCT DATA | 45

Product Data Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp. PERFORMANCE DATA Cooling Capacity LSN/LSU240HSV3, LSN/LSU307HV3 Table 20: LSN240HSV3/LSU240HSV3 Cooling Capacities Outdoor Air Temp. (°F DB) Indoor Air Temperature (°F DB/ °F WB) 64 / 53 68 / 57 72 / 61 77 / 64 80 / 67 86 / 72 90 / 75 TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 0 13.32 10.68 0.68 16.66 11.37 0.81 19.99 12.06 0.93 24.16 12.93 1.09 26.66 13.45 1.19 22.25 14.66 0.97 19.30 15.48 0.82 5 13.07 10.53 0.72 16.34 11.21 0.85 19.61 11.89 0.98 23.70 12.74 1.14 26.15 13.26 1.24 21.82 14.46 1.01 18.93 15.26 0.86 7 13.16 10.62 0.72 16.45 11.31 0.86 19.74 12.00 0.99 23.86 12.86 1.15 26.33 13.38 1.25 21.97 14.59 1.02 19.06 15.40 0.87 10 13.29 10.77 0.73 16.62 11.47 0.87 19.95 12.17 1.00 24.10 13.04 1.17 26.60 13.56 1.27 22.20 14.79 1.04 19.26 15.61 0.88 14 13.47 10.96 0.75 16.84 11.67 0.89 20.22 12.38 1.03 24.43 13.27 1.20 26.96 13.81 1.30 22.50 15.06 1.06 19.52 15.89 0.90 23 14.46 11.77 0.74 17.40 12.53 0.90 20.33 13.30 1.05 24.00 14.25 1.24 26.20 14.82 1.36 23.06 16.16 1.08 20.96 17.06 0.90 25 14.69 11.96 0.76 17.56 12.70 0.91 20.43 13.44 1.06 24.02 14.36 1.25 26.18 14.91 1.36 23.31 16.34 1.10 21.40 17.29 0.93 30 15.25 12.42 0.82 17.97 13.10 0.96 20.68 13.79 1.10 24.08 14.64 1.27 26.11 15.15 1.38 23.94 16.77 1.15 22.50 17.85 0.99 35 15.82 12.88 0.87 18.38 13.51 1.00 20.94 14.14 1.13 24.13 14.92 1.29 26.05 15.39 1.39 24.58 17.21 1.19 23.60 18.42 1.06 40 16.39 13.34 0.93 18.79 13.92 1.05 21.19 14.49 1.16 24.19 15.20 1.31 25.99 15.63 1.40 25.21 17.64 1.23 24.70 18.98 1.13 45 16.96 13.81 0.98 19.20 14.32 1.09 21.44 14.84 1.20 24.24 15.48 1.33 25.93 15.87 1.41 25.85 18.08 1.28 25.79 19.55 1.19 50 17.52 14.27 1.04 19.61 14.73 1.13 21.69 15.19 1.23 24.30 15.76 1.35 25.86 16.11 1.42 26.48 18.51 1.32 26.89 20.11 1.26 55 18.09 14.73 1.09 20.02 15.13 1.18 21.95 15.54 1.26 24.36 16.04 1.37 25.80 16.35 1.43 27.12 18.94 1.37 27.99 20.68 1.32 60 18.66 15.19 1.15 20.43 15.54 1.22 22.20 15.89 1.30 24.41 16.33 1.39 25.74 16.59 1.44 27.75 19.38 1.41 29.09 21.24 1.39 65 18.49 15.05 1.21 20.17 15.48 1.28 21.85 15.90 1.35 23.95 16.43 1.43 25.21 16.75 1.49 27.21 19.39 1.47 28.55 21.15 1.46 70 18.32 14.92 1.27 19.91 15.41 1.33 21.50 15.91 1.40 23.48 16.53 1.48 24.67 16.91 1.53 26.68 19.40 1.53 28.02 21.06 1.53 75 18.15 14.78 1.33 19.65 15.35 1.39 21.14 15.92 1.45 23.01 16.64 1.53 24.14 17.07 1.58 26.14 19.41 1.59 27.48 20.98 1.60 80 17.98 14.64 1.38 19.39 15.29 1.44 20.79 15.94 1.50 22.55 16.74 1.58 23.60 17.23 1.62 25.61 19.42 1.65 26.94 20.89 1.68 85 17.81 14.51 1.44 19.12 15.23 1.50 20.44 15.95 1.56 22.08 16.85 1.63 23.07 17.39 1.67 25.07 19.44 1.72 26.40 20.80 1.75 90 17.64 14.37 1.50 18.86 15.16 1.55 20.09 15.96 1.61 21.62 16.95 1.67 22.53 17.55 1.71 24.53 19.45 1.78 25.87 20.71 1.82 95 17.47 14.23 1.56 18.60 15.10 1.61 19.74 15.97 1.66 21.15 17.06 1.72 22.00 17.71 1.76 24.00 19.46 1.84 25.33 20.62 1.89 100 17.01 13.86 1.58 18.17 14.77 1.63 19.34 15.68 1.69 20.79 16.81 1.75 21.66 17.50 1.79 23.58 19.15 1.86 24.87 20.25 1.92 105 16.56 13.48 1.61 17.75 14.43 1.66 18.94 15.38 1.71 20.42 16.57 1.77 21.31 17.29 1.81 23.17 18.84 1.89 24.41 19.87 1.94 110 16.10 13.11 1.63 17.32 14.10 1.68 18.54 15.09 1.74 20.06 16.33 1.80 20.97 17.07 1.84 22.76 18.53 1.92 23.95 19.50 1.97 115 15.53 12.64 1.65 16.70 13.60 1.70 17.88 14.57 1.75 19.35 15.77 1.82 20.24 16.50 1.86 21.98 17.90 1.94 23.14 18.84 2.00 118 15.18 12.36 1.66 16.34 13.31 1.71 17.49 14.26 1.77 18.93 15.44 1.83 19.80 16.15 1.87 21.52 17.53 1.95 22.66 18.45 2.01 122 14.72 12.61 1.68 15.84 13.57 1.73 16.97 14.54 1.78 18.37 15.75 1.85 19.21 16.48 1.89 20.87 17.88 1.97 21.98 18.82 2.03 Table 21: LSN307HV3/LSU307HV3 Cooling Capacities DB: Dry Bulb Temperature (°F) WB: Wet Bulb Temperature (°F) TC: Total Capacity (kBtu/h) SHC: Sensible Capacity (kBtu/h) PI: Power Input (kW) (includes compressor, indoor fan motor and outdoor fan motor) 1. All capacities are net, evaporator fan motor heat is deducted. 2. Cooling range with the Low Ambient Baffle Kit (sold separately) is 0°F to +122°F. 3. Grey shading indicates reference data. When operating the unit at this temperature, these values can be different by discontinuous operation. 4. Direct interpolation is permissible. Do not extrapolate. Nominal capacity as rated: 0 ft. above sea level with 25 ft. of refrigerant piping. 0 ft. level difference between outdoor and indoor units. Nominal cooling capacity rating obtained with air entering the indoor unit at 80ºF dry bulb (DB) and 67ºF wet bulb (WB), and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB). Outdoor Air Temp. (°F DB) Indoor Air Temperature (°F DB/ °F WB) 64 / 53 68 / 57 72 / 61 77 / 64 80 / 67 86 / 72 90 / 75 TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 0 18.16 14.56 1.17 22.71 15.51 1.38 27.26 16.45 1.59 32.94 17.63 1.86 36.35 18.34 2.02 30.34 20.00 1.65 26.32 21.10 1.40 5 17.82 14.36 1.22 22.28 15.29 1.44 26.74 16.22 1.67 32.31 17.38 1.95 35.66 18.08 2.11 29.75 19.71 1.72 25.82 20.80 1.46 7 17.94 14.49 1.23 22.43 15.43 1.46 26.92 16.37 1.68 32.54 17.54 1.97 35.90 18.24 2.14 29.96 19.89 1.74 26.00 21.00 1.48 10 18.12 14.69 1.25 22.66 15.64 1.48 27.20 16.59 1.71 32.87 17.78 2.00 36.27 18.49 2.17 30.27 20.17 1.77 26.26 21.28 1.50 14 18.37 14.95 1.28 22.97 15.92 1.51 27.57 16.89 1.75 33.31 18.10 2.04 36.76 18.83 2.22 30.68 20.53 1.81 26.62 21.67 1.53 23 19.72 16.05 1.26 23.72 17.09 1.53 27.72 18.13 1.79 32.73 19.43 2.12 35.73 20.21 2.32 31.44 22.04 1.85 28.58 23.27 1.53 25 20.03 16.31 1.30 23.94 17.31 1.56 27.86 18.32 1.81 32.76 19.58 2.13 35.69 20.34 2.33 31.79 22.28 1.88 29.18 23.58 1.58 30 20.80 16.94 1.39 24.50 17.87 1.63 28.21 18.80 1.87 32.83 19.96 2.17 35.61 20.66 2.34 32.65 22.87 1.95 30.68 24.34 1.69 35 21.58 17.57 1.49 25.06 18.42 1.71 28.55 19.28 1.93 32.91 20.35 2.20 35.52 20.99 2.36 33.52 23.46 2.03 32.18 25.11 1.80 40 22.35 18.20 1.58 25.62 18.98 1.78 28.89 19.76 1.98 32.98 20.73 2.23 35.44 21.31 2.38 34.38 24.06 2.10 33.68 25.88 1.92 45 23.12 18.83 1.68 26.18 19.53 1.86 29.24 20.23 2.04 33.06 21.11 2.26 35.35 21.64 2.40 35.25 24.65 2.18 35.17 26.65 2.03 50 23.90 19.46 1.77 26.74 20.08 1.93 29.58 20.71 2.09 33.14 21.50 2.30 35.27 21.97 2.42 36.11 25.24 2.25 36.67 27.42 2.14 55 24.67 20.09 1.87 27.30 20.64 2.01 29.93 21.19 2.15 33.21 21.88 2.33 35.18 22.29 2.44 36.98 25.83 2.33 38.17 28.19 2.26 60 25.45 20.72 1.96 27.86 21.19 2.08 30.27 21.67 2.21 33.29 22.26 2.36 35.10 22.62 2.45 37.84 26.43 2.40 39.67 28.96 2.37 65 25.21 20.53 2.06 27.50 21.11 2.18 29.79 21.68 2.30 32.65 22.40 2.44 34.37 22.84 2.53 37.11 26.44 2.51 38.94 28.84 2.49 70 24.98 20.34 2.16 27.15 21.02 2.27 29.31 21.70 2.39 32.02 22.55 2.53 33.64 23.06 2.61 36.38 26.46 2.61 38.20 28.72 2.61 75 24.75 20.15 2.26 26.79 20.93 2.37 28.83 21.71 2.47 31.38 22.69 2.61 32.91 23.28 2.69 35.65 26.47 2.72 37.47 28.60 2.73 80 24.52 19.97 2.36 26.44 20.85 2.46 28.35 21.73 2.56 30.75 22.83 2.69 32.19 23.49 2.77 34.92 26.49 2.82 36.74 28.48 2.86 85 24.29 19.78 2.46 26.08 20.76 2.56 27.87 21.75 2.65 30.11 22.98 2.77 31.46 23.71 2.84 34.19 26.50 2.92 36.01 28.36 2.98 90 24.05 19.59 2.56 25.72 20.68 2.65 27.39 21.76 2.74 29.48 23.12 2.85 30.73 23.93 2.92 33.46 26.52 3.03 35.27 28.24 3.10 95 23.82 19.41 2.66 25.37 20.59 2.74 26.91 21.78 2.83 28.84 23.26 2.94 30.00 24.15 3.00 32.72 26.53 3.13 34.54 28.12 3.22 100 23.20 18.90 2.70 24.78 20.14 2.79 26.37 21.38 2.87 28.34 22.93 2.98 29.53 23.86 3.05 32.16 26.11 3.18 33.91 27.61 3.27 105 22.58 18.38 2.74 24.20 19.68 2.83 25.82 20.98 2.91 27.85 22.60 3.02 29.06 23.57 3.09 31.60 25.69 3.22 33.29 27.10 3.31 110 21.95 17.87 2.78 23.61 19.23 2.87 25.28 20.58 2.96 27.35 22.27 3.07 28.60 23.28 3.14 31.03 25.27 3.27 32.66 26.59 3.36 115 21.17 17.24 2.81 22.78 18.55 2.90 24.38 19.87 2.99 26.39 21.51 3.10 27.60 22.50 3.17 29.98 24.42 3.31 31.56 25.69 3.40 118 20.70 16.85 2.83 22.28 18.15 2.92 23.85 19.44 3.01 25.82 21.06 3.12 27.00 22.03 3.19 29.34 23.90 3.33 30.90 25.16 3.43 122 20.08 17.19 2.86 21.61 18.51 2.95 23.13 19.83 3.04 25.04 21.48 3.15 26.19 22.47 3.22 28.46 24.38 3.36 29.97 25.66 3.46

46 | PRODUCT DATA

High Efficiency, Standard and Extended Pipe Wall Mount Engineering Manual Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp. Outdoor Air Temp. (°F DB) Indoor Air Temperature (°F DB/ °F WB) 64 / 53 68 / 57 72 / 61 77 / 64 80 / 67 86 / 72 90 / 75 TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 14 12.81 9.92 0.75 14.04 10.87 0.77 14.83 11.48 0.79 15.83 12.26 0.82 16.74 12.96 0.84 17.41 13.48 0.88 18.86 14.60 0.90 17 12.92 10.00 0.75 14.39 11.14 0.77 15.21 11.77 0.79 16.24 12.57 0.82 17.37 13.45 0.84 18.08 14.00 0.88 19.34 14.97 0.90 23 14.31 11.08 0.74 15.38 11.91 0.77 16.45 12.74 0.79 17.52 13.57 0.81 18.85 14.59 0.84 19.66 15.22 0.87 20.73 16.05 0.90 59 17.35 13.43 0.86 18.65 14.44 0.88 19.95 15.45 0.91 21.25 16.45 0.94 21.84 16.91 0.97 23.85 18.46 1.01 25.14 19.47 1.04 70 19.80 15.33 1.26 21.12 16.35 1.30 22.44 17.38 1.34 23.32 18.06 1.38 23.98 18.57 1.43 25.74 19.93 1.48 27.50 21.29 1.53 75 19.55 15.13 1.30 20.87 16.16 1.34 22.20 17.19 1.38 23.10 17.89 1.42 23.76 18.40 1.47 25.41 19.67 1.53 27.28 21.12 1.57 80 19.03 14.74 1.36 20.36 15.76 1.40 21.68 16.79 1.44 22.66 17.55 1.49 23.54 18.23 1.53 25.08 19.42 1.59 26.84 20.78 1.64 85 18.53 14.35 1.45 19.85 15.37 1.49 21.16 16.39 1.54 22.22 17.20 1.59 23.10 17.89 1.64 24.75 19.16 1.70 26.44 20.47 1.75 90 18.02 13.95 1.51 19.34 14.97 1.56 20.65 15.99 1.61 21.78 16.86 1.66 22.66 17.55 1.71 24.42 18.91 1.78 25.91 20.06 1.83 95 17.47 13.53 1.56 18.78 14.54 1.61 20.09 15.56 1.66 21.40 16.57 1.71 22.00 17.03 1.76 24.02 18.60 1.83 25.33 19.61 1.89 100 17.02 13.18 1.58 18.33 14.19 1.63 19.63 15.20 1.68 20.94 16.22 1.74 21.71 16.81 1.79 23.56 18.24 1.86 24.87 19.26 1.92 105 16.56 12.82 1.61 17.87 13.84 1.66 19.18 14.85 1.71 20.48 15.86 1.76 21.43 16.59 1.82 23.10 17.89 1.89 24.41 18.90 1.95 110 16.10 12.47 1.63 17.41 13.48 1.68 18.72 14.49 1.73 20.03 15.51 1.78 20.97 16.24 1.84 22.64 17.53 1.91 23.95 18.55 1.97 115 15.64 12.11 1.64 16.95 13.13 1.69 18.26 14.14 1.75 19.57 15.15 1.80 20.52 15.88 1.86 22.19 17.18 1.93 23.50 18.19 1.99 118 15.18 11.75 1.66 16.50 12.78 1.71 17.60 13.63 1.76 18.92 14.65 1.82 19.80 15.33 1.87 21.45 16.61 1.95 22.66 17.55 2.01 Table 23: LSN240HLV/LSU240HLV Cooling Capacities Table 22: LSN360HV3/LSU360HV3 Cooling Capacities DB: Dry Bulb Temperature (°F) WB: Wet Bulb Temperature (°F) TC: Total Capacity (kBtu/h) SHC: Sensible Capacity (kBtu/h) PI: Power Input (kW) (includes compressor, indoor fan motor and outdoor fan motor) 1. All capacities are net, evaporator fan motor heat is deducted. 2. Cooling range with the Low Ambient Baffle Kit (sold separately) is 0°F to +122°F. 3. Grey shading indicates reference data. When operating the unit at this temperature, these values can be different by discontinuous operation. 4. Direct interpolation is permissible. Do not extrapolate. Nominal capacity as rated: 0 ft. above sea level with 25 ft. of refrigerant piping. 0 ft. level difference between outdoor and indoor units. Nominal cooling capacity rating obtained with air entering the indoor unit at 80ºF dry bulb (DB) and 67ºF wet bulb (WB), and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB). Outdoor Air Temp. (°F DB) Indoor Air Temperature (°F DB/ °F WB) 64 / 53 68 / 57 72 / 61 77 / 64 80 / 67 86 / 72 90 / 75 TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 0 19.98 16.02 1.57 24.98 17.06 1.86 29.99 18.09 2.14 36.24 19.39 2.50 39.99 20.17 2.72 33.37 22.00 2.22 28.95 23.21 1.88 5 19.60 15.79 1.64 24.50 16.81 1.94 29.41 17.84 2.24 35.54 19.12 2.62 39.23 19.88 2.85 32.73 21.68 2.32 28.40 22.88 1.97 7 19.73 15.94 1.66 24.67 16.97 1.96 29.61 18.00 2.27 35.79 19.29 2.65 39.50 20.07 2.88 32.96 21.88 2.35 28.60 23.10 1.99 10 19.94 16.15 1.69 24.93 17.20 2.00 29.92 18.25 2.30 36.16 19.56 2.69 39.90 20.34 2.92 33.29 22.18 2.38 28.89 23.41 2.02 14 20.21 16.45 1.72 25.26 17.51 2.04 30.32 18.58 2.35 36.65 19.91 2.75 40.44 20.71 2.98 33.74 22.58 2.43 29.28 23.83 2.07 23 21.69 17.66 1.70 26.09 18.80 2.05 30.50 19.94 2.41 36.00 21.37 2.85 39.30 22.23 3.12 34.58 24.25 2.49 31.44 25.59 2.07 25 22.03 17.94 1.75 26.34 19.04 2.10 30.65 20.15 2.44 36.03 21.54 2.87 39.26 22.37 3.13 34.96 24.51 2.53 32.10 25.93 2.13 30 22.88 18.63 1.88 26.95 19.65 2.20 31.03 20.68 2.52 36.12 21.96 2.92 39.17 22.73 3.16 35.92 25.16 2.63 33.75 26.78 2.28 35 23.73 19.32 2.00 27.57 20.26 2.30 31.40 21.20 2.59 36.20 22.38 2.96 39.08 23.09 3.18 36.87 25.81 2.73 35.40 27.63 2.43 40 24.58 20.02 2.13 28.18 20.87 2.40 31.78 21.73 2.67 36.28 22.80 3.00 38.98 23.45 3.21 37.82 26.46 2.83 37.04 28.47 2.58 45 25.44 20.71 2.26 28.80 21.48 2.50 32.16 22.26 2.74 36.37 23.22 3.05 38.89 23.80 3.23 38.77 27.11 2.93 38.69 29.32 2.73 50 26.29 21.40 2.39 29.41 22.09 2.60 32.54 22.78 2.82 36.45 23.65 3.09 38.80 24.16 3.26 39.72 27.77 3.03 40.34 30.17 2.89 55 27.14 22.09 2.51 30.03 22.70 2.70 32.92 23.31 2.90 36.53 24.07 3.14 38.70 24.52 3.28 40.67 28.42 3.14 41.99 31.01 3.04 60 27.99 22.79 2.64 30.65 23.31 2.81 33.30 23.83 2.97 36.62 24.49 3.18 38.61 24.88 3.31 41.63 29.07 3.24 43.64 31.86 3.19 65 27.74 22.58 2.77 30.25 23.22 2.93 32.77 23.85 3.09 35.92 24.65 3.29 37.81 25.12 3.41 40.82 29.09 3.38 42.83 31.73 3.35 70 27.48 22.38 2.91 29.86 23.12 3.06 32.24 23.87 3.21 35.22 24.80 3.40 37.01 25.36 3.52 40.02 29.10 3.52 42.02 31.60 3.52 75 27.23 22.17 3.04 29.47 23.03 3.19 31.72 23.89 3.33 34.52 24.96 3.51 36.21 25.60 3.62 39.21 29.12 3.66 41.22 31.46 3.68 80 26.97 21.96 3.18 29.08 22.93 3.31 31.19 23.90 3.45 33.82 25.12 3.62 35.40 25.84 3.73 38.41 29.14 3.80 40.41 31.33 3.85 85 26.72 21.76 3.31 28.69 22.84 3.44 30.66 23.92 3.57 33.12 25.27 3.73 34.60 26.08 3.83 37.61 29.15 3.94 39.61 31.20 4.01 90 26.46 21.55 3.45 28.30 22.75 3.57 30.13 23.94 3.69 32.42 25.43 3.84 33.80 26.32 3.94 36.80 29.17 4.08 38.80 31.07 4.17 95 26.21 21.35 3.58 27.90 22.65 3.70 29.60 23.96 3.81 31.73 25.59 3.95 33.00 26.57 4.04 36.00 29.19 4.22 38.00 30.93 4.34 100 25.52 20.78 3.63 27.26 22.15 3.75 29.00 23.52 3.87 31.18 25.22 4.01 32.49 26.25 4.10 35.38 28.72 4.28 37.31 30.37 4.40 105 24.84 20.22 3.69 26.62 21.65 3.81 28.40 23.08 3.93 30.63 24.86 4.07 31.97 25.93 4.16 34.76 28.26 4.34 36.62 29.81 4.46 110 24.15 19.66 3.74 25.98 21.15 3.86 27.80 22.64 3.98 30.09 24.49 4.13 31.46 25.61 4.22 34.14 27.79 4.40 35.93 29.25 4.52 115 23.29 18.96 3.78 25.06 20.41 3.91 26.82 21.85 4.03 29.03 23.66 4.18 30.36 24.75 4.27 32.97 26.86 4.45 34.72 28.26 4.58 118 22.77 18.54 3.81 24.50 19.96 3.93 26.24 21.38 4.05 28.40 23.16 4.20 29.70 24.23 4.29 32.27 26.29 4.49 33.99 27.67 4.61 122 22.09 18.91 3.85 23.77 20.36 3.97 25.45 21.81 4.09 27.55 23.63 4.24 28.81 24.71 4.34 31.31 26.82 4.53 32.97 28.23 4.66 PERFORMANCE DATA Cooling Capacity LSN/LSU360HV3, LSN/LSU240HLV DB: Dry Bulb Temperature (°F) WB: Wet Bulb Temperature (°F) TC: Total Capacity (kBtu/h) SHC: Sensible Capacity (kBtu/h) PI: Power Input (kW) (includes compressor,indoor fan motor and outdoor fan motor) 1. All capacities are net, evaporator fan motor heat is deducted. 2. Direct interpolation is permissable. Do not extrapolate. Nominal capacity as rated: 0 ft. above sea level with 25 ft. of refrigerant piping. 0 ft. level difference between outdoor and indoor units. Nominal cooling capacity rating obtained with air entering the indoor unit at 80ºF dry bulb (DB) and 67ºF wet bulb (WB), and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB).

PRODUCT DATA | 47

Product Data Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp. Cooling Capacity PERFORMANCE DATA LSN/LSU300HLV, LSN/LSU360HLV DB: Dry Bulb Temperature (°F) WB: Wet Bulb Temperature (°F) TC: Total Capacity (kBtu/h) SHC: Sensible Capacity (kBtu/h) PI: Power Input (kW) (includes compressor,indoor fan motor and outdoor fan motor) 1. All capacities are net, evaporator fan motor heat is deducted. 2. Direct interpolation is permissable. Do not extrapolate. Nominal capacity as rated: 0 ft. above sea level with 25 ft. of refrigerant piping. 0 ft. level difference between outdoor and indoor units. Nominal cooling capacity rating obtained with air entering the indoor unit at 80ºF dry bulb (DB) and 67ºF wet bulb (WB), and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB). Table 24: LSN300HLV/LSU300HLV Cooling Capacities Outdoor Air Temp. (°F DB) Indoor Air Temperature (°F DB/ °F WB) 64 / 53 68 / 57 72 / 61 77 / 64 80 / 67 86 / 72 90 / 75 TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 14 17.47 13.52 1.27 19.14 14.82 1.31 20.22 15.65 1.35 21.59 16.72 1.39 22.82 17.67 1.44 23.74 18.38 1.50 25.72 19.91 1.54 17 17.62 13.64 1.27 19.63 15.20 1.31 20.73 16.05 1.35 22.14 17.15 1.40 23.69 18.34 1.44 24.66 19.10 1.50 26.37 20.42 1.54 23 19.51 15.10 1.27 20.97 16.24 1.31 22.43 17.37 1.35 23.89 18.50 1.39 25.70 19.90 1.43 26.81 20.76 1.49 28.27 21.89 1.53 59 23.66 18.32 1.46 25.43 19.69 1.51 27.20 21.06 1.55 28.97 22.43 1.60 29.79 23.06 1.65 32.52 25.18 1.72 34.29 26.55 1.77 70 27.00 20.91 2.15 28.80 22.30 2.22 30.60 23.69 2.29 31.80 24.62 2.36 32.70 25.32 2.43 35.10 27.18 2.53 37.50 29.04 2.60 75 26.65 20.64 2.21 28.46 22.04 2.28 30.27 23.44 2.35 31.50 24.39 2.43 32.40 25.09 2.50 34.65 26.83 2.60 37.20 28.80 2.68 80 25.96 20.10 2.31 27.76 21.49 2.38 29.56 22.89 2.46 30.90 23.93 2.53 32.10 24.86 2.61 34.20 26.48 2.71 36.60 28.34 2.80 85 25.27 19.56 2.47 27.06 20.95 2.55 28.86 22.35 2.63 30.30 23.46 2.71 31.50 24.39 2.79 33.75 26.13 2.90 36.05 27.91 2.99 90 24.57 19.03 2.58 26.37 20.42 2.66 28.16 21.80 2.74 29.70 23.00 2.82 30.90 23.93 2.91 33.30 25.78 3.03 35.33 27.36 3.12 95 23.83 18.45 2.66 25.61 19.83 2.74 27.40 21.21 2.82 29.18 22.60 2.91 30.00 23.23 3.00 32.75 25.36 3.12 34.53 26.74 3.21 100 23.20 17.97 2.70 24.99 19.35 2.78 26.77 20.73 2.87 28.56 22.11 2.96 29.61 22.93 3.05 32.13 24.88 3.17 33.91 26.26 3.27 105 22.58 17.48 2.74 24.37 18.87 2.83 26.15 20.25 2.92 27.93 21.63 3.01 29.22 22.63 3.10 31.50 24.39 3.22 33.29 25.77 3.32 110 21.96 17.00 2.78 23.74 18.38 2.86 25.53 19.76 2.95 27.31 21.15 3.04 28.60 22.14 3.14 30.88 23.91 3.26 32.66 25.29 3.36 115 21.33 16.52 2.80 23.12 17.90 2.89 24.90 19.28 2.98 26.69 20.66 3.07 27.98 21.66 3.17 30.26 23.43 3.29 32.04 24.81 3.39 118 20.70 16.03 2.83 22.50 17.42 2.92 24.00 18.58 3.01 25.80 19.98 3.10 27.00 20.91 3.20 29.25 22.65 3.32 30.90 23.93 3.42 Table 25: LSN360HLV/LSU360HLV Cooling Capacities Outdoor Air Temp. (°F DB) Indoor Air Temperature (°F DB/ °F WB) 64 / 53 68 / 57 72 / 61 77 / 64 80 / 67 86 / 72 90 / 75 TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 14 19.21 14.88 1.71 21.05 16.30 1.77 22.24 17.22 1.82 23.75 18.39 1.88 25.10 19.44 1.94 26.12 20.22 2.01 28.29 21.90 2.07 17 19.38 15.00 1.72 21.59 16.72 1.77 22.81 17.66 1.82 24.36 18.86 1.88 26.06 20.17 1.94 27.13 21.00 2.02 29.01 22.46 2.08 23 21.46 16.62 1.71 23.07 17.86 1.76 24.67 19.10 1.81 26.28 20.35 1.87 28.27 21.89 1.93 29.49 22.84 2.01 31.10 24.08 2.07 59 26.02 20.15 1.97 27.97 21.66 2.03 29.92 23.17 2.09 31.87 24.68 2.16 32.76 25.37 2.22 35.77 27.70 2.31 37.72 29.20 2.38 70 29.70 23.00 2.90 31.68 24.53 2.99 33.66 26.06 3.08 34.98 27.09 3.18 35.97 27.85 3.27 38.61 29.90 3.41 41.25 31.94 3.51 75 29.32 22.70 2.98 31.31 24.24 3.07 33.29 25.78 3.17 34.65 26.83 3.27 35.64 27.60 3.37 38.12 29.51 3.50 40.92 31.68 3.61 80 28.55 22.11 3.11 30.53 23.64 3.21 32.52 25.18 3.31 33.99 26.32 3.41 35.31 27.34 3.51 37.62 29.13 3.66 40.26 31.17 3.77 85 27.79 21.52 3.33 29.77 23.05 3.43 31.75 24.58 3.54 33.33 25.81 3.64 34.65 26.83 3.76 37.13 28.75 3.91 39.66 30.71 4.02 90 27.03 20.93 3.47 29.00 22.46 3.58 30.98 23.99 3.69 32.67 25.30 3.80 33.99 26.32 3.92 36.63 28.36 4.08 38.87 30.09 4.20 95 26.21 20.30 3.58 28.17 21.82 3.69 30.14 23.33 3.80 32.10 24.85 3.92 33.00 25.55 4.04 36.03 27.89 4.20 37.99 29.41 4.33 100 25.53 19.76 3.64 27.49 21.28 3.75 29.45 22.80 3.86 31.41 24.32 3.98 32.57 25.22 4.11 35.34 27.36 4.27 37.30 28.88 4.40 105 24.84 19.23 3.70 26.80 20.75 3.81 28.76 22.27 3.93 30.73 23.79 4.05 32.14 24.89 4.18 34.65 26.83 4.34 36.62 28.35 4.47 110 24.15 18.70 3.74 26.12 20.22 3.85 28.08 21.74 3.97 30.04 23.26 4.10 31.46 24.36 4.22 33.97 26.30 4.39 35.93 27.82 4.52 115 23.47 18.17 3.77 25.43 19.69 3.89 27.39 21.21 4.01 29.36 22.73 4.13 30.77 23.83 4.26 33.28 25.77 4.43 35.24 27.29 4.57 118 22.77 17.63 3.81 24.75 19.16 3.93 26.40 20.44 4.05 28.38 21.97 4.17 29.70 23.00 4.30 32.18 24.91 4.47 33.99 26.32 4.61

48 | PRODUCT DATA

High Efficiency, Standard and Extended Pipe Wall Mount Engineering Manual Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp. PERFORMANCE DATA Heating Capacity LSN/LSU091HSV3, LSN/LSU121HSV3 Outdoor Air Temp. Indoor Air Temperature (°F DB/ °F WB) °F DB °F WB 60 64 68 70 72 75 86 TC PI TC PI TC PI TC PI TC PI TC PI TC PI -3 -4 5.49 0.50 5.32 0.50 5.27 0.50 5.21 0.49 5.17 0.49 5.07 0.49 4.95 0.49 0 -1 5.97 0.55 5.79 0.55 5.73 0.55 5.68 0.54 5.63 0.54 5.52 0.54 5.39 0.54 6 5 6.32 0.58 6.13 0.57 6.07 0.57 6.01 0.57 5.96 0.57 5.84 0.56 5.70 0.56 10 9 6.60 0.60 6.40 0.59 6.33 0.59 6.27 0.59 6.22 0.59 6.10 0.58 5.95 0.58 16 14 6.81 0.60 6.60 0.60 6.53 0.60 6.47 0.59 6.42 0.59 6.29 0.59 6.14 0.59 19 17 6.94 0.62 6.73 0.62 6.67 0.62 6.60 0.61 6.55 0.61 6.42 0.60 6.27 0.60 24 23 7.62 0.64 7.39 0.63 7.32 0.63 7.25 0.62 7.19 0.62 7.05 0.62 6.88 0.62 32 30 9.15 0.67 8.88 0.66 8.79 0.66 8.70 0.66 8.63 0.66 8.46 0.65 8.26 0.65 41 38 10.51 0.70 10.20 0.69 10.09 0.69 9.99 0.68 9.92 0.68 9.72 0.68 9.49 0.68 43 40 10.85 0.70 10.53 0.70 10.42 0.70 10.32 0.69 10.24 0.69 10.03 0.68 9.79 0.68 47 43 11.36 0.71 11.02 0.71 10.91 0.71 10.80 0.70 10.72 0.70 10.50 0.69 10.25 0.69 53 50 11.48 0.72 11.13 0.71 11.02 0.71 10.91 0.71 10.82 0.71 10.61 0.70 10.36 0.70 59 55 11.74 0.73 11.38 0.72 11.27 0.72 11.16 0.71 11.07 0.71 10.85 0.71 10.59 0.71 64 60 11.99 0.74 11.63 0.74 11.51 0.74 11.39 0.73 11.31 0.73 11.08 0.72 10.82 0.72 70 66 12.22 0.75 11.85 0.75 11.73 0.75 11.61 0.74 11.52 0.74 11.29 0.73 11.02 0.73 75 71 12.39 0.76 12.01 0.76 11.89 0.76 11.77 0.75 11.68 0.75 11.45 0.74 11.18 0.74 78 75 12.50 0.77 12.12 0.76 12.00 0.76 11.88 0.76 11.79 0.76 11.55 0.75 11.28 0.75 Table 26: LSN091HSV3/LSU091HSV3 Heating Capacities Outdoor Air Temp. Indoor Air Temperature (°F DB/ °F WB) °F DB °F WB 60 64 68 70 72 75 86 TC PI TC PI TC PI TC PI TC PI TC PI TC PI -3 -4 7.23 0.70 7.01 0.70 6.94 0.70 6.87 0.69 6.82 0.69 6.68 0.68 6.52 0.68 0 -1 7.87 0.77 7.63 0.76 7.56 0.76 7.48 0.76 7.42 0.76 7.28 0.75 7.10 0.75 6 5 8.33 0.81 8.08 0.80 8.00 0.80 7.92 0.79 7.86 0.79 7.70 0.78 7.52 0.78 10 9 8.70 0.83 8.43 0.82 8.35 0.82 8.27 0.82 8.20 0.82 8.04 0.81 7.85 0.81 16 14 8.97 0.84 8.70 0.83 8.61 0.83 8.53 0.82 8.46 0.82 8.29 0.82 8.09 0.82 19 17 9.15 0.87 8.88 0.86 8.79 0.86 8.70 0.85 8.63 0.85 8.46 0.84 8.26 0.84 24 23 9.90 0.89 9.60 0.88 9.50 0.88 9.41 0.87 9.34 0.87 9.15 0.86 8.93 0.86 32 30 11.57 0.94 11.22 0.93 11.11 0.93 11.00 0.93 10.92 0.93 10.70 0.92 10.44 0.92 41 38 13.06 0.99 12.67 0.98 12.54 0.98 12.42 0.97 12.32 0.97 12.07 0.96 11.79 0.96 43 40 13.44 1.00 13.03 0.99 12.90 0.99 12.77 0.98 12.67 0.98 12.42 0.97 12.12 0.97 47 43 14.00 1.02 13.57 1.01 13.43 1.01 13.30 1.00 13.20 1.00 12.93 0.99 12.63 0.99 53 50 14.14 1.03 13.71 1.02 13.57 1.02 13.43 1.01 13.33 1.01 13.06 1.00 12.75 1.00 59 55 14.46 1.04 14.02 1.03 13.88 1.03 13.74 1.02 13.63 1.02 13.36 1.01 13.04 1.01 64 60 14.76 1.06 14.32 1.05 14.17 1.05 14.03 1.04 13.92 1.04 13.64 1.03 13.32 1.03 70 66 15.04 1.08 14.59 1.07 14.44 1.07 14.30 1.06 14.19 1.06 13.90 1.04 13.57 1.04 75 71 15.25 1.09 14.79 1.08 14.64 1.08 14.50 1.07 14.39 1.07 14.10 1.06 13.76 1.06 78 75 15.39 1.10 14.93 1.09 14.78 1.09 14.63 1.08 14.52 1.08 14.23 1.07 13.89 1.07 Table 27: LSN121HSV3/LSU121HSV3 Heating Capacities DB: Dry Bulb Temperature (°F) WB: Wet Bulb Temperature (°F) TC: Total Capacity (kBtu/h) PI: Power Input (kW) (includes compressor,indoor fan motor and outdoor fan motor) 1. All capacities are net, evaporator fan motor heat is deducted. 2. Direct interpolation is permissable. Do not extrapolate. Nominal capacity as rated: 0 ft. above sea level with 25 ft. of refrigerant piping. 0 ft. level difference between outdoor and indoor units. Nominal cooling capacity rating obtained with air entering the indoor unit at 80ºF dry bulb (DB) and 67ºF wet bulb (WB), and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB).

PRODUCT DATA | 49

Product Data Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp. Outdoor Air Temp. Indoor Air Temperature (°F DB/ °F WB) °F DB °F WB 60 64 68 70 72 75 86 TC PI TC PI TC PI TC PI TC PI TC PI TC PI -3 -4 11.22 1.17 10.88 1.16 10.77 1.16 10.67 1.15 10.58 1.15 10.37 1.14 10.12 1.14 0 -1 12.22 1.29 11.85 1.28 11.73 1.28 11.61 1.26 11.52 1.26 11.29 1.25 11.02 1.25 6 5 12.93 1.35 12.53 1.33 12.41 1.33 12.29 1.32 12.19 1.32 11.95 1.31 11.66 1.31 10 9 13.50 1.39 13.09 1.38 12.95 1.38 12.83 1.36 12.73 1.36 12.47 1.35 12.17 1.35 16 14 13.92 1.40 13.50 1.39 13.36 1.39 13.23 1.38 13.13 1.38 12.87 1.36 12.56 1.36 19 17 14.21 1.45 13.77 1.43 13.64 1.43 13.50 1.42 13.40 1.42 13.13 1.41 12.82 1.41 24 23 15.58 1.50 15.11 1.49 14.96 1.49 14.81 1.47 14.69 1.47 14.40 1.46 14.06 1.46 32 30 18.68 1.62 18.11 1.61 17.93 1.61 17.75 1.59 17.61 1.59 17.26 1.57 16.85 1.57 41 38 21.43 1.73 20.78 1.71 20.57 1.71 20.37 1.69 20.21 1.69 19.80 1.68 19.33 1.68 43 40 22.12 1.76 21.45 1.74 21.23 1.74 21.02 1.72 20.86 1.72 20.44 1.70 19.95 1.70 47 43 23.15 1.80 22.45 1.78 22.22 1.78 22.00 1.76 21.83 1.76 21.39 1.74 20.88 1.74 53 50 23.38 1.81 22.67 1.80 22.44 1.80 22.22 1.78 22.05 1.78 21.61 1.76 21.09 1.76 59 55 23.91 1.83 23.19 1.81 22.95 1.81 22.73 1.80 22.55 1.80 22.10 1.78 21.57 1.78 64 60 24.42 1.87 23.68 1.85 23.44 1.85 23.21 1.83 23.03 1.83 22.57 1.81 22.03 1.81 70 66 24.89 1.89 24.13 1.88 23.89 1.88 23.65 1.86 23.47 1.86 23.00 1.84 22.45 1.84 75 71 25.23 1.92 24.47 1.90 24.22 1.90 23.98 1.88 23.80 1.88 23.32 1.86 22.76 1.86 78 75 25.46 1.94 24.69 1.92 24.44 1.92 24.20 1.90 24.02 1.90 23.53 1.88 22.97 1.88 Table 28: LSN181HSV3/LSU181HSV3 Heating Capacities Heating Capacity PERFORMANCE DATA LSN/LSU181HSV3, LSN/LSU240HSV3 Table 29: LSN240HSV3/LSU240HSV3 Heating Capacities DB: Dry Bulb Temperature (°F) WB: Wet Bulb Temperature (°F) TC: Total Capacity (kBtu/h) PI: Power Input (kW) (includes compressor,indoor fan motor and outdoor fan motor) 1. All capacities are net, evaporator fan motor heat is deducted. 2. Direct interpolation is permissable. Do not extrapolate. Nominal capacity as rated: 0 ft. above sea level with 25 ft. of refrigerant piping. 0 ft. level difference between outdoor and indoor units. Nominal cooling capacity rating obtained with air entering the indoor unit at 80ºF dry bulb (DB) and 67ºF wet bulb (WB), and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB). Outdoor Air Temp. Indoor Air Temperature (°F DB/ °F WB) °F DB °F WB 60 64 68 70 72 75 86 TC PI TC PI TC PI TC PI TC PI TC PI TC PI -3 -4 15.55 1.63 15.07 1.61 14.92 1.61 14.77 1.60 14.66 1.60 14.37 1.58 14.02 1.58 0 -1 16.92 1.79 16.41 1.77 16.24 1.77 16.08 1.75 15.96 1.75 15.64 1.74 15.27 1.74 6 5 17.91 1.87 17.36 1.85 17.19 1.85 17.02 1.83 16.89 1.83 16.55 1.81 16.15 1.81 10 9 18.69 1.93 18.13 1.91 17.94 1.91 17.77 1.89 17.63 1.89 17.28 1.87 16.86 1.87 16 14 19.28 1.95 18.70 1.93 18.51 1.93 18.33 1.91 18.19 1.91 17.82 1.89 17.40 1.89 19 17 19.68 2.01 19.08 1.99 18.89 1.99 18.70 1.97 18.56 1.97 18.18 1.95 17.75 1.95 24 23 21.12 2.07 20.48 2.05 20.27 2.05 20.07 2.03 19.92 2.03 19.52 2.01 19.05 2.01 32 30 24.36 2.22 23.62 2.20 23.38 2.20 23.15 2.18 22.97 2.18 22.51 2.15 21.98 2.15 41 38 27.24 2.35 26.41 2.32 26.15 2.32 25.89 2.30 25.69 2.30 25.17 2.28 24.58 2.28 43 40 27.96 2.38 27.11 2.36 26.84 2.36 26.57 2.33 26.37 2.33 25.84 2.31 25.23 2.31 47 43 29.04 2.43 28.16 2.40 27.88 2.40 27.60 2.38 27.39 2.38 26.84 2.36 26.20 2.36 53 50 29.33 2.45 28.44 2.43 28.15 2.43 27.88 2.40 27.66 2.40 27.11 2.38 26.46 2.38 59 55 30.00 2.48 29.09 2.45 28.80 2.45 28.51 2.43 28.29 2.43 27.72 2.40 27.07 2.40 64 60 30.64 2.52 29.71 2.50 29.41 2.50 29.12 2.48 28.90 2.48 28.32 2.45 27.64 2.45 70 66 31.22 2.56 30.27 2.54 29.97 2.54 29.67 2.51 29.44 2.51 28.85 2.49 28.17 2.49 75 71 31.66 2.60 30.70 2.57 30.38 2.57 30.08 2.55 29.85 2.55 29.25 2.52 28.56 2.52 78 75 31.95 2.62 30.98 2.60 30.66 2.60 30.36 2.57 30.13 2.57 29.52 2.54 28.82 2.54

50 | PRODUCT DATA

High Efficiency, Standard and Extended Pipe Wall Mount Engineering Manual Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp. PERFORMANCE DATA Heating Capacity LSN/LSU307HV3, LSN/LSU360HV3 Table 30: LSN307HV3/LSU307HV3 Heating Capacities Outdoor Air Temp. Indoor Air Temperature (°F DB/ °F WB) °F DB °F WB 60 64 68 70 72 75 86 TC PI TC PI TC PI TC PI TC PI TC PI TC PI -3 -4 18.62 2.04 18.06 2.02 17.87 2.02 17.70 2.00 17.56 2.00 17.21 1.98 16.80 1.98 0 -1 20.27 2.24 19.66 2.22 19.46 2.22 19.26 2.20 19.12 2.20 18.73 2.18 18.29 2.18 6 5 21.45 2.34 20.80 2.32 20.59 2.32 20.38 2.30 20.23 2.30 19.82 2.27 19.35 2.27 10 9 22.39 2.42 21.71 2.39 21.49 2.39 21.28 2.37 21.12 2.37 20.69 2.35 20.20 2.35 16 14 23.10 2.44 22.40 2.42 22.17 2.42 21.95 2.40 21.78 2.40 21.35 2.37 20.84 2.37 19 17 23.57 2.52 22.86 2.49 22.62 2.49 22.40 2.47 22.23 2.47 21.78 2.45 21.26 2.45 24 23 25.12 2.62 24.36 2.59 24.12 2.59 23.88 2.57 23.69 2.57 23.22 2.54 22.67 2.54 32 30 28.62 2.84 27.75 2.81 27.47 2.81 27.20 2.79 26.99 2.79 26.45 2.76 25.82 2.76 41 38 31.73 3.04 30.77 3.01 30.46 3.01 30.15 2.98 29.92 2.98 29.32 2.95 28.63 2.95 43 40 32.51 3.09 31.52 3.06 31.20 3.06 30.89 3.03 30.66 3.03 30.04 3.00 29.33 3.00 47 43 33.67 3.16 32.65 3.13 32.32 3.13 32.00 3.10 31.76 3.10 31.12 3.07 30.38 3.07 53 50 34.01 3.19 32.98 3.16 32.64 3.16 32.32 3.13 32.07 3.13 31.43 3.10 30.68 3.10 59 55 34.78 3.23 33.73 3.19 33.39 3.19 33.06 3.16 32.80 3.16 32.14 3.13 31.38 3.13 64 60 35.52 3.29 34.45 3.26 34.10 3.26 33.76 3.22 33.50 3.22 32.83 3.19 32.05 3.19 70 66 36.20 3.34 35.10 3.30 34.74 3.30 34.40 3.27 34.14 3.27 33.45 3.24 32.66 3.24 75 71 36.70 3.38 35.59 3.35 35.23 3.35 34.88 3.32 34.61 3.32 33.92 3.28 33.11 3.28 78 75 37.04 3.41 35.92 3.38 35.55 3.38 35.20 3.35 34.93 3.35 34.23 3.31 33.42 3.31 Table 31: LSN360HV3/LSU360HV3 Heating Capacities DB: Dry Bulb Temperature (°F) WB: Wet Bulb Temperature (°F) TC: Total Capacity (kBtu/h) PI: Power Input (kW) (includes compressor,indoor fan motor and outdoor fan motor) 1. All capacities are net, evaporator fan motor heat is deducted. 2. Direct interpolation is permissable. Do not extrapolate. Nominal capacity as rated: 0 ft. above sea level with 25 ft. of refrigerant piping. 0 ft. level difference between outdoor and indoor units. Nominal cooling capacity rating obtained with air entering the indoor unit at 80ºF dry bulb (DB) and 67ºF wet bulb (WB), and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB). Outdoor Air Temp. Indoor Air Temperature (°F DB/ °F WB) °F DB °F WB 60 64 68 70 72 75 86 TC PI TC PI TC PI TC PI TC PI TC PI TC PI -3 -4 20.28 2.35 19.67 2.32 19.47 2.32 19.28 2.30 19.13 2.30 18.74 2.28 18.30 2.28 0 -1 22.08 2.58 21.41 2.55 21.19 2.55 20.98 2.53 20.82 2.53 20.41 2.50 19.92 2.50 6 5 23.36 2.69 22.66 2.67 22.43 2.67 22.20 2.64 22.03 2.64 21.59 2.61 21.08 2.61 10 9 24.39 2.78 23.65 2.75 23.41 2.75 23.18 2.73 23.00 2.73 22.54 2.70 22.01 2.70 16 14 25.16 2.81 24.40 2.78 24.15 2.78 23.91 2.75 23.73 2.75 23.25 2.73 22.70 2.73 19 17 25.68 2.90 24.90 2.87 24.64 2.87 24.40 2.84 24.21 2.84 23.73 2.81 23.16 2.81 24 23 27.42 3.05 26.59 3.02 26.32 3.02 26.06 2.99 25.86 2.99 25.34 2.96 24.74 2.96 32 30 31.36 3.41 30.41 3.37 30.10 3.37 29.80 3.34 29.57 3.34 28.98 3.31 28.29 3.31 41 38 34.85 3.72 33.80 3.68 33.45 3.68 33.12 3.65 32.87 3.65 32.21 3.61 31.44 3.61 43 40 35.73 3.80 34.64 3.76 34.29 3.76 33.95 3.72 33.69 3.72 33.02 3.69 32.23 3.69 47 43 37.04 3.92 35.92 3.88 35.55 3.88 35.20 3.84 34.93 3.84 34.23 3.80 33.42 3.80 53 50 37.41 3.96 36.28 3.92 35.91 3.92 35.55 3.88 35.28 3.88 34.57 3.84 33.75 3.84 59 55 38.26 4.00 37.10 3.96 36.73 3.96 36.36 3.92 36.08 3.92 35.36 3.88 34.52 3.88 64 60 39.08 4.07 37.89 4.03 37.51 4.03 37.14 3.99 36.85 3.99 36.11 3.95 35.25 3.95 70 66 39.82 4.13 38.61 4.09 38.22 4.09 37.84 4.05 37.55 4.05 36.80 4.01 35.92 4.01 75 71 40.37 4.19 39.15 4.15 38.75 4.15 38.37 4.11 38.07 4.11 37.31 4.07 36.42 4.07 78 75 40.74 4.23 39.51 4.19 39.11 4.19 38.72 4.15 38.42 4.15 37.65 4.11 36.76 4.11

PRODUCT DATA | 51

Product Data Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp. Heating Capacity PERFORMANCE DATA LSN/LSU240HLV, LSN/LSU300HLV Outdoor Air Temp. Indoor Air Temperature (°F DB/ °F WB) °F DB °F WB 60 64 68 70 72 75 86 TC PI TC PI TC PI TC PI TC PI TC PI TC PI -3 -4 16.29 1.59 15.86 1.57 15.72 1.57 15.59 1.56 15.49 1.56 15.22 1.54 14.91 1.54 -0.4 -1 17.53 1.74 17.07 1.73 16.92 1.73 16.77 1.71 16.66 1.71 16.37 1.69 16.04 1.69 6 5 18.43 1.82 17.93 1.80 17.77 1.80 17.62 1.79 17.50 1.79 17.20 1.77 16.84 1.77 10 9 19.14 1.88 18.62 1.86 18.46 1.86 18.30 1.84 18.17 1.84 17.85 1.82 17.48 1.82 16 14 19.67 1.90 19.14 1.88 18.97 1.88 18.81 1.86 18.68 1.86 18.35 1.84 17.96 1.84 19 17 20.03 1.96 19.49 1.94 19.31 1.94 19.06 1.92 19.01 1.92 18.68 1.90 18.29 1.90 24 23 21.74 2.03 21.20 2.01 21.02 2.01 20.77 1.99 20.72 1.99 20.39 1.97 19.99 1.97 32 30 23.73 2.19 23.19 2.17 23.01 2.17 22.76 2.15 22.72 2.15 22.38 2.13 21.99 2.13 41 38 26.01 2.34 25.47 2.31 25.29 2.31 25.04 2.29 24.99 2.29 24.66 2.27 24.26 2.27 43 40 26.58 2.37 26.04 2.35 25.86 2.35 25.61 2.33 25.56 2.33 25.22 2.30 24.83 2.30 47 43 29.04 2.43 28.16 2.40 27.88 2.40 27.00 2.38 27.39 2.38 26.84 2.36 26.20 2.36 53 50 29.33 2.45 28.44 2.43 28.15 2.43 27.88 2.40 27.66 2.40 27.11 2.38 26.46 2.38 59 55 30.00 2.48 29.09 2.45 28.80 2.45 28.51 2.43 28.29 2.43 27.72 2.40 27.07 2.40 64 60 30.64 2.52 29.71 2.50 29.41 2.50 29.12 2.48 28.90 2.48 28.32 2.45 27.64 2.45 70 66 31.22 2.56 30.27 2.54 29.97 2.54 29.67 2.51 29.44 2.51 28.85 2.49 28.17 2.49 75 71 31.66 2.60 30.70 2.57 30.38 2.57 30.08 2.55 29.85 2.55 29.25 2.52 28.56 2.52 78 75 31.95 2.62 30.98 2.60 30.66 2.60 30.36 2.57 30.13 2.57 29.52 2.54 28.82 2.54 Table 32: LSN240HLV/LSU240HLV Heating Capacities DB: Dry Bulb Temperature (°F) WB: Wet Bulb Temperature (°F) TC: Total Capacity (kBtu/h) PI: Power Input (kW) (includes compressor,indoor fan motor and outdoor fan motor) 1. All capacities are net, evaporator fan motor heat is deducted. 2. Direct interpolation is permissable. Do not extrapolate. Nominal capacity as rated: 0 ft. above sea level with 25 ft. of refrigerant piping. 0 ft. level difference between outdoor and indoor units. Nominal cooling capacity rating obtained with air entering the indoor unit at 80ºF dry bulb (DB) and 67ºF wet bulb (WB), and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB). Outdoor Air Temp. Indoor Air Temperature (°F DB/ °F WB) °F DB °F WB 60 64 68 70 72 75 86 TC PI TC PI TC PI TC PI TC PI TC PI TC PI -3 -4 18.88 2.07 18.39 2.05 18.23 2.05 18.07 2.03 17.95 2.03 17.65 2.01 17.29 2.01 -0.4 -1 20.33 2.27 19.79 2.25 19.62 2.25 19.45 2.23 19.32 2.23 18.98 2.20 18.59 2.20 6 5 21.36 2.37 20.79 2.35 20.61 2.35 20.43 2.33 20.29 2.33 19.94 2.30 19.52 2.30 10 9 22.19 2.45 21.59 2.43 21.40 2.43 21.21 2.40 21.07 2.40 20.70 2.38 20.27 2.38 16 14 22.81 2.47 22.19 2.45 22.00 2.45 21.80 2.43 21.66 2.43 21.27 2.40 20.83 2.40 19 17 23.22 2.55 22.60 2.53 22.39 2.53 22.10 2.50 22.05 2.50 21.65 2.48 21.20 2.48 24 23 25.20 2.65 24.58 2.62 24.37 2.62 24.08 2.59 24.03 2.59 23.64 2.57 23.18 2.57 32 30 27.51 2.86 26.89 2.83 26.68 2.83 26.39 2.80 26.34 2.80 25.95 2.77 25.49 2.77 41 38 30.15 3.04 29.53 3.01 29.32 3.01 29.03 2.98 28.98 2.98 28.59 2.95 28.13 2.95 43 40 30.81 3.09 30.19 3.06 29.98 3.06 29.69 3.03 29.64 3.03 29.25 3.00 28.79 3.00 47 43 33.67 3.16 32.65 3.13 32.32 3.13 32.00 3.10 31.76 3.10 31.12 3.07 30.38 3.07 53 50 34.01 3.19 32.98 3.16 32.64 3.16 32.32 3.13 32.07 3.13 31.43 3.10 30.68 3.10 59 55 34.78 3.23 33.73 3.19 33.39 3.19 33.06 3.16 32.80 3.16 32.14 3.13 31.38 3.13 64 60 35.52 3.29 34.45 3.26 34.10 3.26 33.76 3.22 33.50 3.22 32.83 3.19 32.05 3.19 70 66 36.20 3.34 35.10 3.30 34.74 3.30 34.40 3.27 34.14 3.27 33.45 3.24 32.66 3.24 75 71 36.70 3.38 35.59 3.35 35.23 3.35 34.88 3.32 34.61 3.32 33.92 3.28 33.11 3.28 78 75 37.04 3.41 35.92 3.38 35.55 3.38 35.20 3.35 34.93 3.35 34.23 3.31 33.42 3.31 Table 33: LSN300HLV/LSU300HLV Heating Capacities

52 | PRODUCT DATA

High Efficiency, Standard and Extended Pipe Wall Mount Engineering Manual Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp. PERFORMANCE DATA Heating Capacity LSN/LSU360HLV Outdoor Air Temp. Indoor Air Temperature (°F DB/ °F WB) °F DB °F WB 60 64 68 70 72 75 86 TC PI TC PI TC PI TC PI TC PI TC PI TC PI -3 -4 20.77 2.56 20.23 2.53 20.05 2.53 19.88 2.51 19.75 2.51 19.41 2.48 19.02 2.48 -0.4 -1 22.36 2.81 21.77 2.78 21.58 2.78 21.39 2.76 21.25 2.76 20.88 2.73 20.45 2.73 6 5 23.50 2.94 22.87 2.91 22.67 2.91 22.47 2.88 22.32 2.88 21.93 2.85 21.48 2.85 10 9 24.41 3.03 23.75 3.00 23.54 3.00 23.34 2.97 23.18 2.97 22.77 2.94 22.30 2.94 16 14 25.09 3.07 24.41 3.04 24.20 3.04 23.98 3.01 23.82 3.01 23.40 2.98 22.91 2.98 19 17 25.55 3.16 24.86 3.13 24.63 3.13 24.31 3.10 24.25 3.10 23.82 3.07 23.32 3.07 24 23 27.72 3.28 27.03 3.24 26.81 3.24 26.49 3.21 26.43 3.21 26.00 3.18 25.50 3.18 32 30 30.26 3.54 29.57 3.50 29.35 3.50 29.03 3.47 28.97 3.47 28.54 3.43 28.04 3.43 41 38 33.17 3.77 32.48 3.73 32.26 3.73 31.93 3.70 31.87 3.70 31.44 3.66 30.94 3.66 43 40 33.89 3.83 33.21 3.79 32.98 3.79 32.66 3.75 32.60 3.75 32.17 3.72 31.67 3.72 47 43 37.04 3.92 35.92 3.88 35.55 3.88 35.20 3.84 34.93 3.84 34.23 3.80 33.42 3.80 53 50 37.41 3.96 36.28 3.92 35.91 3.92 35.55 3.88 35.28 3.88 34.57 3.84 33.75 3.84 59 55 38.26 4.00 37.10 3.96 36.73 3.96 36.36 3.92 36.08 3.92 35.36 3.88 34.52 3.88 64 60 39.08 4.07 37.89 4.03 37.51 4.03 37.14 3.99 36.85 3.99 36.11 3.95 35.25 3.95 70 66 39.82 4.13 38.61 4.09 38.22 4.09 37.84 4.05 37.55 4.05 36.80 4.01 35.92 4.01 75 71 40.37 4.19 39.15 4.15 38.75 4.15 38.37 4.11 38.07 4.11 37.31 4.07 36.42 4.07 78 75 40.74 4.23 39.51 4.19 39.11 4.19 38.72 4.15 38.42 4.15 37.65 4.11 36.76 4.11 Table 34: LSN360HLV/LSU360HLV Heating Capacities DB: Dry Bulb Temperature (°F) WB: Wet Bulb Temperature (°F) TC: Total Capacity (kBtu/h) PI: Power Input (kW) (includes compressor,indoor fan motor and outdoor fan motor) 1. All capacities are net, evaporator fan motor heat is deducted. 2. Direct interpolation is permissable. Do not extrapolate. Nominal capacity as rated: 0 ft. above sea level with 25 ft. of refrigerant piping. 0 ft. level difference between outdoor and indoor units. Nominal cooling capacity rating obtained with air entering the indoor unit at 80ºF dry bulb (DB) and 67ºF wet bulb (WB), and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB).

“Equipment Selection Procedure” on page 54

“Building Ventilation Design Guide” on page 57 “Placement Considerations” on page 59 APPLICATION GUIDELINES

54 | APPLICATION GUIDELINES

Single Zone High Efficiency and Standard Wall Mount Engineering Manual Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. Cooling / Heating Correction Factors For the Single Zone High Efficiency, Single Zone Standard and Single Zone Extended Pipe systems, calculate the equivalent length of the liquid line from the outdoor unit to the indoor unit. Also, determine the elevation difference of the indoor unit above or below the outdoor unit. Find corresponding cooling or heating capacity correction factors as shown in Figures 17-22. Multiply the correction factors by the cooling or heating capacity obtained from the capacity tables using design conditions. The resultant is the NET cooling or heating capacity. EQUIPMENT SELECTION PROCEDURE Figure 17: LS091HSV3, LS121HSV3 Cooling Coefficient Factor 9k,12k 65.6 98.4 Total Pipe Length (ft) Capacity(%) Capacity(%) 100 90 95 24.6 100 95 9k,12k 65.6 98.4 24.6 Total Pipe Length (ft) Figure 18: LS091HSV3, LS121HSV3 Heating Coefficient Factor

APPLICATION GUIDELINES | 55

Application Guidelines Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. Figure 19: LS181HSV3, LS240HSV3, LS307HV3, LS360HV3 Cooling Coefficient Factor Cooling Heating 24k,30k,36k 18k Total Pipe Length (ft) 100 95 90 24.6 100 95 18k 24k,30k,36k Total Pipe Length (ft) Capacity(%) Capacity(%) 65.6 98.4 24.6 65.6 98.4 Figure 20: LS181HSV3, LS240HSV3, LS307HV3, LS360HV3 Heating Coefficient Factor EQUIPMENT SELECTION PROCEDURE

56 | APPLICATION GUIDELINES

Single Zone High Efficiency and Standard Wall Mount Engineering Manual Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. EQUIPMENT SELECTION PROCEDURE Figure 21: LS240HLV, LS300HLV, LS360HLV Cooling Coefficient Factor Cooling Heating 24k,30k,36k 98.4 164.0 Total Pipe Length(ft) 100 95 90 24.6 98.4 164.0 24.6 100 95 24k,30k,36k Total Pipe Length(ft) Capacity(%) Capacity(%) Figure 22: LS240HLV, LS300HLV, LS360HLV Heating Coefficient Factor

APPLICATION GUIDELINES | 57

Application Guidelines Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. BUILDING VENTILATION DESIGN GUIDE Building Ventilation Design Guide ASHRAE 62.1 and local codes specify the minimum volume of outdoor air that must be provided to an occupied space. Outdoor air is required to minimize adverse health effects, and it provides acceptable indoor air quality for building occupants. The three methods of accomplishing this with single zone systems are summarized here. Although we believe that these building ventilation methods have been portrayed accurately, none of the methods have been tested, verified, or evaluated by LG Electronics, U.S.A., Inc., In all cases, the designer, installer, and contractor should understand if the suggested method is used, it is used at their own risk. LG Electronics U.S.A., Inc., takes no responsibility and offers no warranty, expressed or implied, of merchantability or fitness of purpose if this method fails to perform as stated or intended. • For a complete copy of Standard 62.1-2010, refer to the American Standard of Heating and Air Conditioning Engineers (ASHRAE) website at www.ashrae.org. • For more information on how to properly size a ventilation air pretreatment system, refer to the article, “Selecting DOAS Equipment with Reserve Capacity” by John Murphy, published in the ASHRAE Journal, April 2010. Method 1: Decoupled Dedicated Outdoor Air System (DDOAS) Advantages • Does not add additional heating or cooling loads to indoor units. • May be used with all single zone systems. • If the outdoor air unit fails, the resulting untreated air will be readily noticed by the occupants. • The outdoor air unit may supply “neutral” air to the occupant space even when the single zone system indoor unit fan changes speed or cycles on and off. DDOAS controls do not have to be interlocked with the single zone system. • In lieu of installing localized smaller outside air treatment equipment throughout the building, this method centralizes the ventilation air source making service and filter changes easier and less disruptive for the building occupants. Disadvantages • Ceiling space is required to accommodate ductwork between the centralized outdoor air unit and ceiling diffusers. LG recommends using the DDOAS method in all installations. Provide a separate, dedicated outdoor-air system designed to filter, condition, and dehumidify ventilation air and deliver it directly to the conditioned space through a separate register or grille. This approach requires a separate independent ventilation duct system not associated with single systems (Figure 23). Methodology illustrations are for examples only and do not depict actual indoor units for the specific outdoor unit pairing. These are generic illustrations to show ventilation design only.. Figure 23: Decoupled Dedicated Outdoor System Diagram • Indoor unit operation and performance will not be affected by the condition of outdoor air. • Third-party demand control ventilation controls are more readily accommodated. Ceiling Diffuser Outdoor Air Unit / ERV Outdoor Air Wall Mount Inverter Intake Grill

58 | APPLICATION GUIDELINES

Single Zone High Efficiency and Standard Wall Mount Engineering Manual Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. BUILDING VENTILATION DESIGN GUIDE Method 2: Unconditioned Outdoor Air (Non-Ducted, Natural Ventilation) Natural ventilation devices, such as operable windows or louvers may be used to ventilate the building when local code permits. The open area of a window or the free area of a louver must meet the minimum percentage of the net occupied floor area. Refer to Figure 8. Advantages • Occupants control the volume of the ventilation air manually. • Useful for historic buildings that have no ceiling space available for outdoor air ductwork. • May be used with all single zone systems. Disadvantages • In some locations, it may be difficult to control humidity levels when windows are open. • Thermal comfort levels may be substandard when windows are open. • Indoor units may have to be oversized to account for the added heating and cooling loads when windows are open. • Provides outdoor air to perimeter spaces only. Additional mechanical ventilation system may be required to satisfy require- ments for interior spaces. • Outdoor air loads may be difficult to calculate since the quantity of outdoor air is not regulated. • May affect indoor unit proper operation when open. Methodology illustrations are for examples only and do not depict actual indoor units for the specific outdoor unit pairing. These are generic illustrations to show ventilation design only. Figure 24: Unconditioned Outdoor Air (Non-Ducted) Method 3: Unconditioned Outdoor Air (Non-Ducted, Fan Assisted Ventilation) When approved by local codes, the fan assisted ventilation method uses exhaust fans to remove air from the building, and outdoor air is drawn into occupied spaces through a wall louver or gravity roof intake hood. Supply fans can also be used to push the outdoor air into the space and building positive pressure will vent the exhaust air through louvers or roof-mounted exhaust hoods. Outdoor air is neither cooled nor heated before entering the building. Refer to Figure 24. This may result in loss of building pressurization control, increasing infiltration loads with adverse effects. Advantages • Outdoor air may be manually controlled by the occupant or auto- matic controls may be installed to open/close outdoor air dampers or to turn on/off ventilation fans. • Useful for large open spaces like warehouses, garages, and workshops. • Outdoor air volume is a known quantity. Air loads may be easier to calculate since fans will regulate the amount of outdoor air. • May be used with all single zone systems. Disadvantages • In some locations of the country, it may be difficult to control humidity levels while outdoor air louvers/hoods are opened. • Thermal comfort levels may be substandard when louvers/hoods are opened. • Indoor units may have to be oversized to account for the added heating/cooling loads when louvers/hoods are open. • Hot, cold, and/or humid areas may be present if the outdoor air is not evenly distributed to the different spaces. Methodology illustrations are for examples only and do not depict actual indoor units for the specific outdoor unit pairing. These are generic illustrations to show ventilation design only. Figure 25: Unconditioned Outdoor Air Fan Assisted Ventilation OA Wall Louver Damper Roof Fan

APPLICATION GUIDELINES | 59

Application Guidelines Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. PLACEMENT CONSIDERATIONS Selecting the Best Location Select a location for installing the outdoor unit that will meet the following conditions: • Where the unit will not be subjected to direct thermal radiation from other heat sources. • Where operating sound from the unit will not disturb inhabitants of surrounding buildings. • Where the unit will not be exposed to direct, strong winds. • Where there is enough strength to bear the weight of the unit. • Include space for drainage to ensure condensate flows properly out of the unit when it is in heating mode. • Include enough space for air flow and for service access. • To avoid the possibility of fire, do not install the unit in an area where combustible gas may generate, flow, stagnate, or leak. • Do not install the unit in a location where acidic solution and spray (sulfur) are often used. • Do not use the unit in environments where oil, steam, or sulfuric gas are present. • Install a fence to prevent vermin from crawling into the unit or unauthorized individuals from accessing it. To ensure the outdoor unit operates properly, certain measures are required in locations where there is a possibility of heavy snowfall or severe windchill or cold: 1. Prepare for severe winter wind chills and heavy snowfall, even in areas of the country where these are unusual phenomena. 2. Position the outdoor unit so that its airflow fans are not buried by direct, heavy snowfall. If snow piles up and blocks the airflow, the 3. system may malfunction. 4. Remove any snow that has accumulated 3-15/16 inches or more on the top of the outdoor unit. 5. Place the outdoor unit on a raised platform at least 19-11/16 inches higher than the average annual snowfall for the area. In environments where there is a possibility of heavy snow, the frame height must be more than two (2) times the amount of average annual snowfall, and should not exceed the width of the outdoor unit. If the frame width is wider than the outdoor unit, snow may accumulate. 6. Install a snow protection hood. 7. To prevent snow and heavy rain from entering the outdoor unit, install the suction and discharge ducts facing away from direct winds. 8. Additionally, the following conditions should be taken into considerations when the unit operates in defrost mode: • If the outdoor unit is installed in a highly humid environment (near an ocean, lake, etc.), ensure that the site is well-ventilated and has a lot of natural light. (Example: Install on a rooftop.) • Sidewalks or parking lots near the outdoor unit may accumulate moisture after unit operates in defrost mode that can turn to ice. The indoor unit may take longer to provide heat, or heating performance will be reduced in winter if the unit is installed: 1. In a narrow, shady location. 2. Near a location that has a lot of ground moisture. 3. In a highly humid environment. 4. In an area in which condensate does not drain properly.

60 | APPLICATION GUIDELINES

Single Zone High Efficiency and Standard Wall Mount Engineering Manual Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. PLACEMENT CONSIDERATIONS Outdoor Unit Installation General Mounting Securely attach the outdoor unit to a condenser pad, base rails, or another mounting platform that is securely anchored to the ground or building structure. Attach the outdoor unit with a bolt and nut on a concrete or rigid mount. See Figure 26. Refer to the applicable installation manual and follow applicable local codes for clearance, mounting, anchor and vibration attenuation requirements. All referenced materials are to be field-supplied. Images are not to scale.. Figure 26: Outdoor Unit Mounting Methods Bolt Placement & Anti-Vibration Pad Piping Connection Top of Unit Foundation Mounting Platform The underlying structure or foundation must be designed to sup- port the weight of the unit. Avoid placing the unit in a low lying area where water may accumulate. When installing the outdoor unit on the wall, or roof top, anchor the mounting base securely to account for wind, earthquake or vibration. Tie-Downs and Wind Restraints The strength of the Duct-free Split Single Zone Inverter system frame is adequate to be used with field-provided wind restraint tie- downs. The overall tie-down configuration must be approved by a local professional engineer. Always refer to local code when design- ing a wind restraint system. Snow and Ice Conditions In climates that experience snow build-up, place the unit on a raised platform to ensure condenser airflow. The raised support platform must be high enough to allow the unit to remain above possible snow drifts. Mount the unit on a field-provided snow stand at a minimum height that is equal to the average annual snowfall plus 20 inches. Design the mounting base to prevent snow accumulation on the platform in front or back of the unit case. If necessary, provide a field fabricated hood to keep snow and ice and/or drifting snow from accumulating on the coil surfaces. Use inlet and discharge duct or hoods to prevent snow or rain from accumulating on the fan inlet and outlet guards. Best practice prevents snow from accumulating on top of the unit. Consider tie-down requirements in case of high winds or where required by local codes. When deciding on a location to place the outdoor unit, be sure to choose an area where run-off from defrost will not accumulate and freeze on sidewalks or driveways. Ambient Air Conditions Avoid exposing the outdoor unit to steam, combustible gases, or other corrosive elements. Avoid exposing the unit to discharge from boiler stacks, chimneys, steam relief ports, other air conditioning units, kitchen vents, plumbing vents, and other sources of extreme temperature, gases, or substances that may degrade performance or cause damage to the unit. When installing multiple outdoor units, avoid placing units where the discharge of one outdoor unit will blow into the inlet side of an adjacent unit.

APPLICATION GUIDELINES | 61

Application Guidelines Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. PLACEMENT CONSIDERATIONS Outdoor Unit Installation Outdoor Unit Clearance Proper clearance through the outdoor unit coil is critical for proper unit operation. When installing the outdoor unit, consider service, inlet and outlet and minimum allowable space requirements as illustrated in the diagrams below. Specific clearance requirements in the diagram below are for the single zone wall mount systems. Figure 27 shows the overall minimum clearances that must be observed for safe operation and adequate airflow around the outdoor unit. Figure 27: Outdoor Unit Clearances Outdoor Unit Clearance 11-3/16 27-19/32 23-19/32 11-3/16 23-19/32 Unit : inch When placing the outdoor unit under an overhang, awning, sunroof or other “roof-like structure, observe the clearance requirements (as shown in Figure 27) for height in relation to the unit. This clearance ensures that heat radiation from the condenser is not restricted around the unit. Adhere to all clearance requirements if installing the unit on a roof. Be sure to level the unit and ensure that the unit is adequately anchored. Consult local codes for rooftop mounting requirements. Do not place the unit where animals and/or plants will be in the path of the warm air, or where the warm air and/or noise will disturb neighbors. Figure 28: Outdoor Unit Sunroof/Awning Clearances More than 11-13/16 More than 11-13/16 Sunroof Fence or obstacles More than 27-19/32 Unit : inch More than 23-19/32

62 | REFRIGERANT DESIGN

Single Zone High Efficiency and Standard Wall Mount Engineering Manual Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp.

“Refrigerant Piping Design” on page 64

“Installation & Best Layout Practices” on page 66 “Electrical Connections” on page 71 REFRIGERANT PIPING DESIGN AND BEST LAYOUT PRACTICES

64 | REFRIGERANT DESIGN

Single Zone High Efficiency and Standard Wall Mount Engineering Manual Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. REFRIGERANT PIPING DESIGN Design Guideline Summary Device Connection Limitations Single zone systems consist of one outdoor unit and one indoor unit. One of the most critical elements of a single zone system is the refriger- ant piping. Tables 35-37 list pipe length limits that must be followed in the design of a Single Zone Wall Mount refrigerant pipe system. Refer to Figure 29 for maximum length and elevation of piping Table 35: Single Zone High Efficiency Refrigerant Piping System Limitations. Pipe Length (ELF = Equivalent Length of pipe in Feet) Longest total equivalent piping length LS091HSV3 LS121HSV3 LS181HSV3 LS240HSV3 65.6 65.6 98.4 98.4 Distance between fittings and indoor units or outdoor units ≥20 inches ≥20 inches ≥20 inches ≥20 inches Elevation (All Elevation Limitations are Measured in Actual Feet) If outdoor unit is above indoor unit 32.8 32.8 49.2 49.2 If outdoor unit is below indoor unit 32.8 32.8 49.2 49.2 Additional Refrigerant Needed (oz/ft) 0.22 0.22 0.38 0.38 Table 36: Single Zone Standard Refrigerant Piping System Limitations. Table 37: Single Zone Extended Pipe Refrigerant Piping System Limitations. Figure 29: Single Zone System Layout Outdoor unit Indoor unit A B Outdoor unit Indoor unit A B Max Length = A Max Elevation = B Unit = Feet Pipe Length (ELF = Equivalent Length of pipe in Feet) Longest total equivalent piping length LS307HV3 LS360HV3 98.4 98.4 Distance between fittings and indoor units or outdoor units ≥20 inches ≥20 inches Elevation (All Elevation Limitations are Measured in Actual Feet) If outdoor unit is above indoor unit 49.2 49.2 If outdoor unit is below indoor unit 49.2 49.2 Additional Refrigerant Needed (oz/ft) 0.38 0.38 Pipe Length (ELF = Equivalent Length of pipe in Feet) Longest total equivalent piping length LS240HLV LS300HLV LS360HLV 164.0 164.0 164.0 Distance between fittings and indoor units or outdoor units ≥20 inches ≥20 inches ≥20 inches Elevation (All Elevation Limitations are Measured in Actual Feet) If outdoor unit is above indoor unit 98.4 98.4 98.4 If outdoor unit is below indoor unit 98.4 98.4 98.4 Additional Refrigerant Needed (oz/ft) 0.38 0.38 0.38

REFRIGERANT DESIGN | 65

Refrigerant Piping Design & Layout Best Practices Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. REFRIGERANT PIPING DESIGN Selecting Field-Supplied Copper Tubing Pipe Length1 Fluid Temperature °F 35° 40° 45° 50° 55° 60° 65° 70° 75° 80° 85° 90° 95° 100° 105° 110° 115° 120° 125° 130° 10 0.04 0.04 0.05 0.06 0.06 0.07 0.08 0.08 0.09 0.09 0.10 0.10 0.11 0.11 0.11 0.12 0.13 0.14 0.15 0.15 20 0.08 0.08 0.10 0.12 0.13 0.14 0.15 0.16 0.17 0.18 0.19 0.20 0.21 0.22 0.22 0.23 0.26 0.28 0.29 0.30 30 0.12 0.12 0.15 0.18 0.20 0.21 0.23 0.24 0.26 0.27 0.29 0.30 0.32 0.33 0.32 0.35 0.39 0.42 0.44 0.45 40 0.16 0.16 0.20 0.24 0.26 0.28 0.30 0.32 0.34 0.36 0.38 0.40 0.42 0.44 0.43 0.46 0.52 0.56 0.58 0.60 50 0.20 0.20 0.25 0.30 0.33 0.35 0.38 0.40 0.43 0.45 0.48 0.50 0.53 0.55 0.54 0.58 0.65 0.70 0.73 0.75 60 0.24 0.24 0.30 0.36 0.39 0.42 0.45 0.48 0.51 0.54 0.57 0.60 0.63 0.66 0.65 0.69 0.78 0.84 0.87 0.90 Table 38: Linear Thermal Expansion of Copper Tubing in Inches. 1Pipe length baseline temperature = 0°F. "Expansion of Carbon, Copper and Stainless Steel Pipe," The Engineers' Toolbox, www.engineeringtoolbox.com. Figure 30: Coiled Expansion Loops and Offsets. Large Tubing U-bend (>3/4 in.) Loop Small Tubing U-bend (<3/4 in.) R L R L L Anticipated Linear Expansion (LE) (inches) Nominal Tube Size (OD) inches 1/4 3/8 1/2 3/4 1/2 R1 6 7 8 9 L2 38 44 50 59 1 R1 9 10 11 13 L2 54 63 70 83 1-1/2 R1 11 12 14 16 L2 66 77 86 101 2 R1 12 14 16 19 L2 77 89 99 117 2-1/2 R1 14 16 18 21 L2 86 99 111 131 3 R1 15 17 19 23 L2 94 109 122 143 3-1/2 R1 16 19 21 25 L2 102 117 131 155 4 R1 17 20 22 26 L2 109 126 140 166 1R = Centerline Length of Pipe. 2L = Centerline Minimum Radius (inches). Table 39: Radii of Coiled Expansion Loops and Developed Lengths of Expansion Offsets.

66 | REFRIGERANT DESIGN

Single Zone High Efficiency and Standard Wall Mount Engineering Manual Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. INSTALLATION & LAYOUT BEST PRACTICES Refrigerant Piping System Layout Physical Pipe Length: Actual length of straight segment(s) of pipe. Equivalent Pipe Length: Actual length of pipe plus equivalent lengths of elbows, Y-branches, and valves. 1. Draft a one-line diagram of the proposed piping system connecting outdoor unit to heat recovery and indoor units. Follow the pipe limitations listed on page 64. 2. Calculate the physical length of each pipe segment and note it on the drawing. 3. Calculate the equivalent pipe length of each pipe segment. Using Elbows Field-supplied elbows are allowed as long as they are designed for use with R410A refrigerant. The designer, however, should be cautious with the quantity and size of fittings used, and must account for the additional pressure losses in equivalent pipe length calculation. The equivalent pipe length of each elbow must be added to each pipe segment. See Table 40 for equivalent lengths. Table 40: Equivalent Piping Length for Piping Components. Definitions Layout Procedure Component Size (Inches) 1/4 3/8 1/2 5/8 3/4 Elbow (ft.) 0.5 0.6 0.7 0.8 1.2 Field-Provided Isolation Ball Valves It is acceptable to install field-supplied ball valves with Schrader ports at the indoor unit. Full-port isolation ball valves with Schrader ports (positioned between valve and indoor unit) rated for use with R410A refrigerant should be used on both the liquid and vapor lines. If valves are not installed and the indoor unit needs to be removed or repaired, the entire system must be shut down and evacuated. Position valves with a minimum distance of three (3) to six (6) inches of pipe on either side of the valve. Valves must be easily accessible for service. If necessary, install drywall access doors or removable ceiling panels, and position the valves to face the access door or ceiling panel open- ing. Mount valves with adequate space between them to allow for placement of adequate pope insulation around the valves. Recommended best practice is to clearly label and document locations of all service valves. The equivalent pipe length of each ball valve must be added to each pipe segment. Obstacles When an obstacle, such as an I-beam or concrete T, is in the path of the planned refrigerant pipe run, it is best practice to route the pipe over the obstacle. If adequate space is not available to route the insulated pipe over the obstacle, then route the pipe under the obstacle. In either case, it is imperative the horizontal section of pipe above or below the obstacle be a minimum of three (3) times greater than the longest vertical rise (or fall) distance. Refer to Figure 31. Figure 31: Installing Piping Above and Below an Obstacle Above an obstacle. 3X Below an obstacle.

REFRIGERANT DESIGN | 67

Refrigerant Piping Design & Layout Best Practices Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. REFRIGERANT PIPING DESIGN No Pipe Size Substitutions Using a different size is prohibited and may result in a system malfunction or failure to work at all. In-line Refrigeration Components Components such as oil traps, solenoid valves, filter-dryers, sight glasses, tee fittings, and other after-market accessories are not permitted on the refrigerant piping system between the outdoor unit and the indoor unit. Single Zone Wall Mount systems are provided with redundant systems that assure oil is properly returned to the compressor. Sight-glasses and solenoid valves may cause vapor to form in the liquid stream. Over time, dryers may deteriorate and introduce debris into the system. The designer and installer should verify the refrigerant piping system is free of traps, sagging pipes, sight glasses, filter dryers, etc. Pipe Supports A properly installed pipe system should be adequately supported to avoid pipe sagging. Sagging pipes become oil traps that lead to equipment malfunction. Pipe supports should never touch the pipe wall; supports shall be installed outside (around) the primary pipe insulation jacket (see Figure 31). Insulate the pipe first because pipe supports shall be installed outside (around) the primary pipe insulation jacket. Clevis hangers should be used with shields between the hangers and insulation. Field provided pipe supports should be designed to meet local codes. If allowed by code, use fiber straps or split-ring hangers suspended from the ceiling on all-thread rods (fiber straps or split ring hangers can be used as long as they do not compress the pipe insulation). Place a second layer of insulation over the pipe insulation jacket to prevent chafing and compression of the primary insulation within the confines of the support pipe clamp. A properly installed pipe system will have sufficient supports to avoid pipes from sagging during the life of the system. As necessary, place supports closer for segments where potential sagging could occur. Maximum spacing of pipe supports shall meet local codes. If local codes do not specify pipe support spacing, pipe shall be supported: • Maximum of five feet (5′) on center for straight segments of pipe up to 3/4" outside diameter size. Wherever the pipe changes direction, place a hanger within twelve (12) inches on one side and within twelve to nineteen (12 to 19) inches of the bend on the other side as shown in Figure 32. Figure 32: Pipe Hanger Details. Figure 33: Typical Pipe Support Location— Change in Pipe Direction. Figure 34: Pipe Support at Indoor Unit. Max. 12" ~ 12" – 19" A B A + B ~ 12" – 19" Refrigerant Piping System Layout

68 | REFRIGERANT DESIGN

Single Zone High Efficiency and Standard Wall Mount Engineering Manual Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. INSTALLATION & LAYOUT BEST PRACTICES Refrigerant Piping System Layout Pipe Sleeves at Penetrations LG requires that all pipe penetrations through walls, floors, and pipes buried underground be properly insulated and routed through an appropriate wall sleeve of sufficient size to prevent compression of refrigerant pipe insulation and free movement of the pipe within the sleeve. Underground refrigerant pipe shall be routed inside a protective sleeve to prevent insulation deterioration. Refer to Figure 35. Figure 35: Pipe Sleeve Options. Diameter of penetrations shall be determined by pipe diameter plus the thickness of the insulation. Vapor Line Liquid Line Min. 18 Gauge Communications Cable Pipe Sleeve Insulation Material Insulation Material Underground Refrigerant Piping Refrigerant pipe installed underground should be routed inside a vapor tight protective sleeve to prevent insulation deterioration and water infiltration. Refrigerant pipe installed inside underground casing must be continuous without any joints. Underground refrigerant pipe must be located at a level below the frost line. Figure 36: Typical Arrangement of Refrigerant Pipe and Cable(s) in a Utility Conduit. Table 41: Utility Conduit Sizes. 1OD pipe diameter in inches; Values in parenthesis () indicate OD of pipe with insulation jacket. 2Diameter of pipe with insulation. Thickness of pipe insulation is typical. Actual required thickness may vary based on surrounding ambient conditions and should be calculated and specified by the design engineer. 3Insulation thickness (value in parenthesis) = 3/8 inch. 4Insulation thickness (value in parenthesis) = 1 inch. Liquid Pipe1 Vapor Pipe1 3/8 (1-1/82,3) 1/2 (2.02,4) 5/8 (2-1/82,4) 1/4 (1.0)3 4 4 4 3/8 (1-1/8)3 4 4 4 Table 42: Heat Pump Unit Refrigerant Pipe Connections (All Brazed Type) Model Liquid Conn. (inches) Vapor Conn. (inches) LSU091HSV3, LSU121HSV3 1/4 3/8 LSU181HSV3, LSU240HSV3 3/8 5/8 LSU307HV3, LSU360HV3 3/8 5/8 LSU240HLV, LSU300HLV, LSU360HLV 3/8 5/8

REFRIGERANT DESIGN | 69

Refrigerant Piping Design & Layout Best Practices Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. INSTALLATION & LAYOUT BEST PRACTICES Piping Connection Single Zone Wall Mount Outdoor Unit Connections 1. Remove the tubing cover by loosening the fastening screws. See Figure 37. 2. Align the center of the refrigerant pipe and corresponding connection as shown in Figure 38. 3. Place a couple of drops of refrigerant oil on the opening rim of the flare before assembling. Ensure you do not add any contaminants. Tighten the flare nut initially by hand. 4. Finish tightening the flare nut with a torque wrench until the wrench clicks. See Figure 39. Figure 37: Outdoor Unit Connection Cover Removal Tubing Cover When tightening the flare nut with a torque wrench, ensure the direction for tightening follows the arrow on the wrench.. Table 43: Torque Wrench Tightening Outside Diameter (inches) Torgue (lbs-ft) 1/4 13-18 3/8 24.6-30.4 1/2 39.8-47.7 5/8 45.6-59.3 3/4 71.6-87.5 Figure 38: Pipe Attachment Figure 39: Heat Pump Outdoor Unit Piping Connection Outdoor Unit Gas Side Piping (larger diameter) Liquid Side Piping (smaller diameter) Torque Wrench

70 | REFRIGERANT DESIGN

Single Zone High Efficiency and Standard Wall Mount Engineering Manual Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. INSTALLATION & LAYOUT BEST PRACTICES Refrigerant Piping System Layout All joints are brazed in the field. Duct-free Split Single Zone Inverter refrigeration system components contain very small capillary tubes, small orifices, electronic expansion valves, oil separators, and heat exchangers that can easily become blocked. Proper system operation depends on the installer using best practices and utmost care while assembling the piping system. • While brazing, use a dry nitrogen purge operating at a minimum pressure of three (3) psig and maintain a steady flow. • Blow clean all pipe sections with dry nitrogen prior to assembly. • Use a tubing cutter, do not use a saw to cut pipe. De-burr and clean all cuts before assembly. • Store pipe stock in a dry place. Keep pipe capped and clean. • Use adapters to assemble different sizes of pipe. • Do not use flux, soft solder, or anti-oxidant agents. • Use a 15% silver phosphorous copper brazing alloy to avoid overheating and produce good flow. • Protect isolation valves, electronic expansion valves, and other heat-sensitive control components from excessive heat with a wet rag or a heat barrier spray product Installation of Refrigerant Piping / Brazing Practices Pressure-reducing Valve Valve Taping Nitrogen Pipe to be brazed Refrigerant Piping Figure 40: Refrigerant Pipe Brazing. It is imperative to keep the piping system free of contaminants and debris such as copper burrs, slag, or carbon dust during installation. Refrigerant Piping System Insulation All refrigerant piping including Y-branch and Header connections, field-provided isolation ball valves, service valves, and elbows shall be completely insulated using closed cell pipe insulation. The liquid and vapor lines must be insulated separately. To prevent heat loss/heat gain through the refrigerant piping, all refrigerant piping including liquid lines and vapor lines shall be insulated separately. Insulation shall be a minimum 1/2″ thick, and thickness may need to be increased based on ambient conditions and local codes. All insulation joints shall be glued with no air gaps. Insulation material shall fit snugly against the refrigeration pipe with no air space between it and the pipe. Insulation passing through pipe hangers, inside conduit, and/or sleeves must not be compressed. Protect insulation inside hangers and supports with a second layer. All pipe insulation exposed to the sun and outdoor elements shall be properly protected with PVC, aluminum vapor barrier, or alternatively placed in a weather-resistant enclosure such as a pipe rack with a top cover; and meet local codes. The design engineer should perform calculations to determine if the factory-supplied insulation jackets are sufficient to meet local codes and avoid sweating. Add additional insulation if necessary. Mark all pipes at the point where the insulation jacket ends. Remove the jacket. Install field provided insulation on the run-out and main truck pipes first. Peel the adhesive glue protector slip from the insulation jacked and install the clam-shell jacket over the fitting.

REFRIGERANT DESIGN | 71

Refrigerant Piping Design & Layout Best Practices Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. ELECTRICAL CONNECTIONS Figure 41: Outdoor Unit Connection Terminal Block Connecting Cable Power Supply Cord Conduit Panel Tubing Cover Over 0.2” Outdoor Electrical Connection 1. Remove the control cover from the unit by loosening the fastening screw. Refer to Figure 41. 2. Take off the caps on the conduit panel. 3. Connect both the power supply and low voltage lines to the corresponding terminals on the terminal block. See Figures 43-46. 4. Be sure to ground the unit by following local codes. 5. Allow for enough length (add several inches) for each wiring. 6. Secure the cable with the cord clamp. 7. Secure conduit tubes with lock nuts. 8. Reattach the control cover to the original position with the fastening screw. Always use a circuit breaker or time delay fuse when connecting electrical wiring to the unit.. • Comply with local codes while running wire from the indoor unit to the outdoor unit.. • Ensure you connect the wire firmly. • Separately wire the high and low voltage lines. • Use heat-proof electrical wire capable of withstanding temperatures up to 167°F. • Use outdoor and waterproof connection cable rated up to 300V for the connection between the indoor and outdoor unit. • Do not allow wire to touch refrigerant tubing, the compressor or any moving parts. Figure 42: Circuit Breaker Air Conditioner Main Power Source Circuit Breaker Use a circuit breaker or time delay fuse

72 | REFRIGERANT DESIGN

Single Zone High Efficiency and Standard Wall Mount Engineering Manual Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. ELECTRICAL CONNECTIONS Figure 43: Terminal Block Wiring Diagram - LSU091HSV3, LSU121HSV3 Figure 44: Terminal Block Wiring Diagram - LSU181HSV3, LSU240HSV3 208/230 VAC Figure 45: Terminal Block Wiring Diagram - LSU307HV3, LSU360HV3 Figure 46: Terminal Block Wiring Diagram - LSU240HLV, LSU300HLV, LSU360HLV

74 | REFRIGERANT DESIGN

Single Zone High Efficiency and Standard Wall Mount Engineering Manual Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. MECHANICAL SPECIFICATIONS General LG Single Zone High Efficiency, Single Zone Standard and Single Zone Extended Pipe systems are comprised of a single outdoor unit connected to a single indoor unit with a single refrigerant circuit. These single zone systems can operate in either cooling or heating mode. These systems are capable of changing mode within a maximum time of three (3) minutes to ensure temperature can be properly maintained. LG components are manufactured in a facil- ity registered to ISO 9001 and ISO 14001, which is a set of standards applying to envi- ronmental protection set by the International Organization for Standardization (ISO). The units are listed by Intertek Electrical Testing Laboratories (ETL) and bear the ETL label. Wiring in these units are in accordance with the National Electrical Code (NEC). Temperature Ranges Outdoor Unit Operating ranges for outdoor units of 14°F to 118°F DB for cooling and -4°F to 75°F WB for heating. Indoor Unit Operating ranges for indoor units of 64°F to 90°F WB for cooling and 60°F to 86°F DB for heating. Installing an optional Low Ambient Wind Baffle Kit will allow operation down to 0°F in cooling mode for all single zone systems. Casing / Frame Outdoor unit is constructed with pre-coated metal (PCM). Indoor unit is constructed of heavy duty Ac- rylonitrile Butadiene Styrene (ABS) and High Impact Polystyrene (HIPS) plastic. Refrigerant System The refrigeration system consists of a single refrigeration circuit and uses R410A refriger- ant. The outdoor unit is provided with factory installed components, including a refrigerant strainer, four-way reversing valve, electronic controlled expansion valve (EEV), high and low side charging ports, service valves, and interconnecting piping. Refrigeration Oil Control Heat pump outdoor units have a centrifugal oil separator and controls to ensure suf- ficient oil supply is maintained, and that oil does not travel with the refrigerant. Compressors The outdoor unit is equipped with one hermetic digitally controlled inverter driven rotary (9k/12k Btu/h systems) or twin rotary (18k/24k/30k/36k Btu/h systems) compres- sor to modulate capacity (modulation in 1 Hz increments). Frequency ranges for the outdoor units are as follows: LSU091HSV3, LSU121HSV3, LSU181HSV3 = 15-100 Hz LSU240HSV3 = 20-100 Hz LSU307HV3, LSU360HV3 = 20-100 Hz LSU240HLV, LSU300HLV, LSU360HLV = 10-100 Hz. Overcurrent protection and vibration isolation are integrated with the compressor. Outdoor Unit Coil Heat pump outdoor unit coils are made of a nonferrous construction with louvered fins on copper tubing, and are protected with an integral coil guard. Coil fans have a factory applied corrosion resistant GoldFinTM mate- rial with hydrophilic coating. Fans and Motors The outdoor unit includes one direct fan drive, variable speed variable speed propeller type fan. The Brushless Digitally Controlled (BLDC) fan motor shall have inherent protection, permanently lubricated bearings, and variable speed with a maximum speed up to 950 rpm. Raised guards are provided to limit contact with moving parts. The outdoor unit has horizontal discharge airflow. Electrical These units are available in 208-230V, 60 Hz, 1-phase power supply. These units are capable of operating within voltage limits of ± 10% rated voltage, and include overcurrent protection. Controls These units are factory wired with necessary electrical components, integral microproces- sors, printed circuit boards, thermistors, sensors, terminal blocks, and lugs for power wiring. Microprocessor-based algorithms provide component protection, soft-start capability, refrigeration system pressure, temperature, defrost, and ambient control.

REFRIGERANT DESIGN | 75

Refrigerant Piping Design & Layout Best Practices Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp. ACRONYMS ABS Acrylonitrile Butadiene Styrene H/M/L High/Medium/Low AC Air Conditioner HVAC Heating, , Ventilation and Air Conditioning ACP Advanced Control Platform IDU Indoor Unit ASHRAE American Society of Heating, Refrigeration, and Air Conditioning ISO International Organization for Standardization AWG American Wire Gauge kW Kilo Watts BLDC Brushless Digitally Controlled/Direct LED Light Emitting Diode Btu/h British Thermal Units per hour MBh Thousands BTUs per hour BUS Binary Unit System MCA Maximum Circuit Ampacity CFM Cubic Feet per Minute MOP Maximum Overcurrent Protection COP Coefficient Of Performance ODU Outdoor Unit CR Combination Ratio PCB Printed Circuit Board DB Dry Bulb PCM Pre-Coated Metal dB(A) Decibels with “A” frequency weighting PDI Power Distribution Indicator DDOAS Decoupled Dedicated Outdoor Air PI Power Input DO Digital Output PTAC Packaged Terminal Air Conditioner DPST Double-Pole Single-Throw (switch) PVC Polyvinyl Chloride EEV Electronic Expansion Valve USB Universal Serial BUS ELF Equivalent Length in Feet VAC Voltage Alternating Current ESP External Static Pressure VAV Variable Air Volume ETL Electronic Testing Laboratories VRF Variable Refrigerant Flow HIPS High Impact Polystyrene WB Wet Bulb Table 44: Table of Acronyms.

Commercial Air Conditioning Division

4300 North Point Parkway Alpharetta, Georgia 30022 www.lghvac.com www.lg-dfs.com EM-SZ-HighEfficiencyWallmount-HSV3-HV3-HLV-9-16 Supersedes: EM-SZ-HighEfficiencyWallmount-HSV3-HV3-HLV-6-16 DFS-EM-AH-001-US 014D10 20001747 ISO 9001: 2008 LG ELECTRONICS INC. LG Electronics Commercial Products Support 1-888-865-3026 USA Follow the prompts for commercial A/C products.