Key Pages of Document

2. Safety Information

2.1 Safety Standards 1. Overview 2.3 Precautions 2.4 Electrical Symbols ................................................................01 3. Description 3.1 Front Panel 3.2 Display 3.3 Button Funtions 4. Operating Instructions 4.1 AC/DC voltage 4.2 AC/DC current 3.4 Auto Power Off 5. Specifications 5.1 General Specifications 5.2 Technical Specifications 4.3 Resistance 4.4 Continuity 4.5 Diode test 4.6 Battery test 4.7 Temperature 6. Maintenance 6.1 General Maintenance 6.2 Replacing the Battery 6.3 Replacing the Fuse 4.8 Non-Contact Voltage 4.9 Wireless Operation ...

±(0.8% of reading +3digits)

0.01MΩ 40MΩ If measured resistanceis less than 50Ω, buzzer will sound 5.2.5 Continuity Function Description Description Open circuit voltage: ~1V 5.2.4 Diode Test Display shows forward voltage drop Function Description Resolution 3V Diode Test Range 1mV ±(1.2% of reading +3digits) 5.2 Technical Specifications Accuracy: ±(% of reading + digits) at 18°C~28°C with a relative humidity of <80%; guaranteed for a period of one year. Resolution Accura ...

6.4 Replacing the Probe

If�insulation�on�probe�is�damaged,�replace�it. WARNING Use meet EN 61010-031 standard, rated CAT III 600V, 10A or better probe. 7. Accessories Test Leads 1set Package 1pcs 9V Battery 1pcs User's Manual 1pcs K type thermocouple 1pcs 6.2 Replacing the Battery WARNING To avoid false readings and potential dangerous situations, replace the battery immidately when the “ ” symbol appears. Turn off the meter and disconnect the test leads before opening the battery cover to prevent electrical shock and personal injury. Use the following steps to repl ...

To prevent injury or damage to the meter,turn off power to

circuit and discharge all capacitors fully before making continuity measurements. 4.5 Diode test • Turn off power to the circuit. Allow all capacitors to discharge. • Set the rotary switch to the multi-function position. Press “FUNC” once to enter diode mode. • Connect the red test lead to the input jack and the black lead to the COM jack. • Connect the red test lead to the anode (+) and the black lead to the cathode (-) of the diode and read the measurement on the display. The meter will display “OL ...

Never measure open-circuit voltages exceeding 600V between

the input terminals and ground to prevent injury or damage to the meter 07 08 4. Operating Instructions WARNING Do not measure voltages higher than 600V DC or ACrms to prevent damage to the meter or personal injury 4.1 AC/DC voltage measurement • • Press “FUNC” to switch between AC and DC voltage. • Connect the red test lead to the input jack and the black lead to the COM jack. • Connect the leads to the circuit under test and read the measurement on the display. Observe polarity for DC measurements. In manual ...

±(2.0% of reading +2 digits)

• Use a damp cloth to regularly clean the outside of the meter.Do not use abrasives or chemical solvents. Dirty or damp input jack can adversely affect readings. • To clean input jacks, follow the following steps: 1.Turn off the instrument and remove the test leads. 2.Clear any dirt or other particles on the input jacks. 3.Use a cotton ball/swab with a lubricant (i.e. WD-40) to clean off the contacts of the input jacks. 4.Use a separate cotton ball/swab for each jack to p ...

2. Safety Information

2.1 Safety Standards 1. Overview 2.3 Precautions 2.4 Electrical Symbols ................................................................01 3. Description 3.1 Front Panel 3.2 Display 3.3 Button Funtions 4. Operating Instructions 4.1 AC/DC voltage 4.2 AC/DC current 3.4 Auto Power Off 5. Specifications 5.1 General Specifications 5.2 Technical Specifications 4.3 Resistance 4.4 Continuity 4.5 Diode test 4.6 Battery test 4.7 Temperature 6. Maintenance 6.1 General Maintenance 6.2 Replacing the Battery 6.3 Replacing the Fuse 4.8 Non-Contact Voltage 4.9 Wireless Operation ...

5.1 General Specifications

When battery voltage drops below shown on the display Polarity Indication Display automatically displays “-” Function Range Max. Input between terminals and earth ground 600V DC or AC T-RMS Fuse Protection Sample Rate Approx. 3 times/sec. Display 3 digit LCD display Overload Indication Display shows “OL” Low Battery Indication Temperature coefficient 0.1xaccuracy/°C (>18°C or <28°C) Power Supply DC 9V (NEDA 1604, 6F22 or 006P) Size(LxWxH) Approx. 148x73.5x50mm weight Approx. 232g Safety Rating CAT III 600V, pollution degree of 2 ...

Mastech MS8238H user guide recommended for: MS8230B, MS8238C, MS8040, MY67, MS8229.

⚠️ Download Safety

The Multimeter Operation & user’s manual (12 pages) is completely safe to download (last scan date: 10/02/2026).

Related PDF Instructions for Mastech MS8238H:

Multimeter Equipment: Frequently Requested

Have some Questions about Mastech MS8238H Device?

Get valuable and actionable advices from other Mastech MS8238H device users. Describe your problem or question, regarding the using of MS8238H, in as much detail as possible, and other users will be able to answer you.