Marantec CS 310 Operating Instructions Manual

Text of the manual

2 – CS 310 Gate Controls / Rev.G 1.54

1. Contents 1. Contents 2 2. Information in this document 2 3. General safety instructions 3 4. Product overview 4 5. Initial operation 6 6. Initialisation 15 7. Setting the end positions 16 8. Programming 18 9. Navigator (LCD monitor only) 20 10. Overview of functions 22 11. Error messages and rectification 37 12. Technical data 40 13. Maintenance 42 14. EC Declaration of conformity 43 15. Appendix 44 Original operating instructions − − Copyright. − − No part of these instructions may be reproduced without our prior approval. − − Subject to alterations in the interest of technical progress. − − All dimensions given in mm. − − The diagrams in this manual are not to scale. Key to symbols DANGER! Indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. WARNING! Indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. CAUTION! Indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. ATTENTION! Indicates an imminent danger of damage or destruction. CHECK Indicates a check to be performed. REFERENCE Reference to separate documents which must be complied with.   Action request − − List, itemisation Ô Ô Reference to other sections of this document 2. Information in this document

CS 310 Gate Controls / Rev.G 1.54 – 3

3. General safety instructions DANGER! Failure to comply with the documentation could result in life-threatening danger!   Be sure to follow all the safety instructions in this docu- ment. Warranty The function and safety of the equipment is only guaranteed if the warning and safety instructions included in these operating instructions are adhered to. Marantec GmbH + Co. KG is not liable for personal injury or damage to property if these occur as a result of the warnings and safety advice being disregarded. Marantec does not accept any liability or warranty for damage due to the use of non-approved spare parts and accessories. Use for the intended purpose The CS 310 control is intended exclusively for the purpose of controlling door systems operated using mechanical limit switches or an electronic end position system (AWG absolute value encoder). Target group Only qualified and trained electricians may connect, programme and service the control. Qualified and trained electricians must meet the following requirements: − − knowledge of the general and specific safety and accident prevention regulations. − − knowledge of the relevant electrical regulations, − − training in the use and care of appropriate safety equipment. − − capable of recognising the dangers associated with electricity. Instructions regarding installation and connection − − The control is designed with X type terminals. − − The system must be disconnected from the electricity supply before carrying out any electrical work. It must be ensured that the electricity supply remains disconnected for the duration of the work. − − Local protective regulations must be complied with. − − Consult the manufacturer before carrying out modifications or replacing the mains connection cable. Information concerning operation − − Unauthorised persons (particularly children) should not be allowed to play with permanently installed adjusting or control devices. − − Keep remote controls beyond the reach of children. Regulations and bases for testing For connecting, programming and servicing, the following regulations must be observed (the list is not exhaustive). Construction product standards − − EN 13241-1 (Products without fire resistance or smoke control characteristics) − − EN 12445 (Safety in use of power operated doors - Test methods) − − EN 12453 (Safety in use of power operated doors - Requirements) − − EN 12978 (Safety devices for power operated doors and gates - Requirements and test methods) EMC − − EN 55014-1 (Radio disturbance, household appliances) − − EN 61000-3-2 (Disturbances in supply systems - harmonic currents) − − EN 61000-3-3 (Disturbances in supply systems - voltage fluctuations) − − DIN EN 61000-6-2 (Electromagnetic compatibility (EMC) - Part 6-2: Generic standards – Immunity for industrial environments) − − DIN EN 61000-6-3 (Electromagnetic compatibility (EMC) - Part 6-3: Generic standards – Emission standard for residential, commercial and light-industrial environments) Machinery Directive − − EN 60204-1 (Safety of machinery, electrical equipment of machines; Part 1: General requirements) − − EN ISO 12100 (Safety of machinery – general principles for design - risk assessment and risk reduction) − − EN 13849-1 (Safety of machinery – Safety-related parts of control systems – Part 1: General principles for design)

4 – CS 310 Gate Controls / Rev.G 1.54

Low voltage − − DIN EN 60335-1 (Household and similar electrical appliances - Safety - Part 1: General requirements) − − DIN EN 60335-2-103 (Household and similar electrical appliances - Safety - Part 2-103: Particular requirements for drives for gates, doors and windows) Committee for Workplaces (Ausschuss für Arbeitsstätten - ASTA) − − ASR A1.7 (Technical Regulations for workplaces - Doors and gates) 4. Product overview 4.1 Versions The following package options are available for the CS 310 control: − − CS 310 control with LCD monitor − − CS 310 control with LCD monitor in housing − − CS 310 control without LCD monitor (monitor is required for all settings except the end position setting) All the above versions can be fitted with a plug-in weekly timer, a plug-in radio receiver and a plug-in transmission sys- tem (for a closing edge safety device and/or a safety element). The following options are available for the housing: − − Housing unit with 3-button input unit CS − − Housing with ON/OFF key switch − − Housing with main switch − − Housing with Emergency Stop switch The operating instructions describe the connection and programming options for the various versions: − − CS 310 control with LCD monitor connected and software version 1.54 or later General safety instructions

CS 310 Gate Controls / Rev.G 1.54 – 5

4.2 Motherboard CS 310 (with plugged-in LCD monitor) Key: X1: Terminal block for mains connection X2: Terminal block for motor X3: Terminal block for command devices X4: Terminal block for safety elements X5: Terminal block for relay X6: Sockets for internal ON-OFF switch X7: Sockets for internal 3-button input unit X8: Sockets for LCD monitor (under the LCD monitor) X9: Sockets for radio receiver X10: Sockets for weekly timer X11: Sockets for digital end position system X12: Sockets for external radio receiver X13: Sockets for CS three-button input unit X14: Interface RS 485 - Connection for CSI button input - Connection for RS 485 display X15: Terminal block for mechanical end position system X16: Sockets for BUS system (MS BUS) X17: Sockets for BUS system (MS BUS) X18: Frequency converter interface X19: Power supply for external devices 230V / 50 Hz protected by F1 (1 A delay) fuse X20: Sockets for transmission system H4: operational readiness Lights up when power supply available. H6: Status message Lights up when the safety devices are actuated or if an error occurs S1: Programming button (+) (under the LCD monitor) S2: Programming button (-) (under the LCD monitor) S3: Programming button (P) (under the LCD monitor) X11 X14 X18 B2 B1 W V X2 U 1 2 3 4 5 6 7 8 X5 1 2 3 4 5 6 7 8 X15 X10 1 2 3 4 5 6 7 8 9 10 X4 X3 X7 X6 X12 PE PE PE N L3 L2 L1 X1 1 2 3 4 5 6 7 8 9 12 11 10 X8 S3 S2 S1 X9 X20 H6 X13 X19 F1 X16 X17 H4 N L X19 N L X19 400 V 230 V A B B A Output: 230 V. Power supply for external devices. No power line entry for the control unit itself. Ô Ô “5.3 Power supply for external devices (only for 400 V / 3-phase connection)“ B The position of the jumper must take into account the power supply voltage and the ­motor voltage.