MAX SMART SG2 Installation And User Manual
Text of the manual
1. Status / GSM Signal Indicator
2. Power / Network status Indicator
3. Panic
(SOS)
4. Panel
5. Stand
6. Monitoring MIC
SIM
1. SIM Card Slot
2. Connect
3. Power
4. Adapter Interface
5. USB Upgrade Port
2
3
- 16-bit high speed processor, reliable capability
-
100% wireless
D.I.Y.
- Built-in 1,000,000 RF codes
-
Supports 10 remote controls and 100 wireless sensors.
- The alarm system can be controlled by SMS, App or phone call
- Stores 5 phone numbers and 5 SMS numbers for alarm alert
- Supports exit and entry delay arm / alert
- Wireless self-learning code
- Adding new accessories fast and easy
- Supports arm and disarm by App
- Supports remote monitor by App
- Supports remote control / arm / disarm / monitor by phone
-
SMS
for power
power recovery and low
-
Supports global GSM 850/900/1800/1900MHz
-
Support Wi-Fi 802.11b/g/n
Control Panel Features
Features
1. Status / Low Power Indicator
Blue(off):system is disarmed
Blue
system is armed
Blue (blinking): the alarm has been triggered
2. Power / GSM Signal Indicator
Product name:
SG2 GSM+WiFi
Power supply:
Input: AC 110~240V/50~60Hz
Output: DC 12V/1A
GSM working frequency:
850/900/1800/1900MHz
Standby current:
60mAh
Alarm current:
120mAh
Built-in
7.4V 500mAh lithium
Support wireless accessories:
10 remote control, 100 wireless detectors
Wireless receiving frequency:
315 MHz / 433MHz (±75KHz)
Siren volume:
90dB
Housing material:
ABS
Temperature: -10°C ~ +55°C
Humidity: ≤80%
(non-condensing)
White(Fast blinking):searching GSM network
White(slow blinking): GSM signal is normal
Wi-Fi:
802.11b/g/n
Quick Start-up Guide
First�operations�
Store a phone number
To interact with the control panel by SMS, by phone call and/or from the app, at least one phone number
must�be�stored�in�the�control�panel.�Please�refer�to�the�instructions�on�“Store�Phone�Numbers”�on�page�
7�of�this�manual.
Change the language
By�default�the�language�of�the�SG2�control�panel�is�set�to�English.�If�you�wish�to�change�the�system�
language,�refer�to�the�instructions�“Change�system�language”�on�page�12�of�this�manual.�“System�
language”�refers�to�the�language�of�the�SMS�you�receive�from�the�control�panel.
Arm / Disarm the system
The�alarm�system�can�be�armed�or�disarmed�by�SMS,�by�App�and�by�phone�call.
By SMS
To�arm�the�system:�Send�“1”�by�SMS�to�the�number�of�your�system’s�SIM�card.
To�disarm�the�system:�Send�“0”�by�SMS�to�the�number�of�your�system’s�SIM�card.
By app
Click�on�“Arm”�in�the�app�to�arm�the�system,�and�“Disarm”�to�disarm�the�system.�The�app�is�available�
for�download�on�the�App�Store�and�Google�Play.
Register wireless accessories
1.� Press�the�connection�button�at�the�back�of�the�control�panel�to�enter�the�Connection�mode.
2.� Trigger�the�accessory�once�within�the�next�15�seconds.�You�hear�one�beep:�the�registration�is�
successful.�
If�the�accessory�has�already�been�registered,�the�control�panel�will�beep�twice.�The�first�accessory�
registered�is�assigned�to�zone�1,�the�second�accessory�registered�is�assigned�to�zone�2,�etc.�Zones�
1�to�9�can�be�renamed.�Zones�10�to�99�cannot�be�renamed�(refer�to�the�instructions�on�page�9�to�
learn�how�to�rename�zones).
Control by Phone Call
Method 1
When�an�alarm�has�been�triggered,�the�control�panel�dials�the�pre-stored�phone�numbers.�When�
you�pick�up�the�phone,�control�the�panel�from�distance�according�to�the�instructions�in�the�table�
below).
Method 2
1.�Dial�the�telephone�number�of�the�SIM�card�in�your�control�panel.
2.�Enter�your�user�code,�followed�by�”#”.�After each key you press on your phone, you hear one beep
of confirmation. Wait until you have heard this beep of confirmation before pressing the next key.
3.�Select�the�operations�to�control�the�panel�(see�instructions�in�the�table�below).
Note
The�call�will�end�automatically�if�you�do�not�send�any�command�within�30�seconds.
Voice�Instructions
Command
Function
Press “1“
Arms the system
Press “0“
-� Disarms�the�system�and�turns�the�siren�off
- Stops monitoring without hanging up
-� Stops�the�phone�call�function�without�hanging�up
Press “ “
-� Starts�audio�monitoring�mode�(not�limited�in�time)
-� Stops�the�built-in�siren�and�the�wireless�siren�(if�connected�to�the�control�panel)
Press “6“
Turns�all�sirens�off
Press “9“
-� Turns�the�built-in�siren�on�(whether�the�siren�ringing�settings�is�ON�or�OFF)
-� Turns�the�wireless�siren�on�(if�connected�to�the�control�panel)
Press “#“
-� Turns�all�sirens�off
- Exits control by phone call
- Stops call recycles
Note
In�GSM�mode,�the�audio�monitoring�is�not�limited�in�time.
Hard Reset
Press�the�Connect�button�and�the�Panic�button�(SOS)�simultaneously.�Release�them�after�3�beeps.�
Wait�10�seconds.�The�panel�beeps�twice:�the�system�is�restored�to�default�settings.
Stored�phone�numbers�and�accessories�will�also�be�deleted.
Zone setup of accessories
Every�detector�can�be�assigned�to�4�different�categories�of�zones:�Home�Mode�Zone,�Delay�Zone,�
Normal�Zone�and�24-H�Zone.�To�assign�a�detector�to�a�zone,�open�its�case�and�move�its�jumpers�
according�to�the�drawing�below:
D0
D3
D0
D3
D0
D3
D3
D0
A. Home�Mode�Zone
B. Delay�Zone
C. Normal�Zone
D. 24-H�Zone
Normal zone
When�the�system�is�armed,�if�a�sensor�is�triggered,�the�siren�rings�out.�When�the�system�is�disarmed,�
sensors�do�not�trigger�an�alarm.
24h zone
Regardless�the�system�is�armed�or�disarmed,�sensors�assigned�to�the�24h�zone�can�trigger�an�alarm.�
It is recommended to set smoke detectors, gas detectors and outdoor beam sensors in the 24-H zone.
Delay zone
An�entry�and�an�exit�delay�can�be�set.�In�such�case,�sensors�assigned�to�the�“Delay�Zone”�will�not�
trigger�an�alarm�during�the�time�of�delay�set.�For�example,�if�you�assign�a�motion�detector�to�the�
Delay�zone�and�you�set�the�Entry/Exit�Delay�to�30�seconds,�the�motion�detector�will�not�trigger�an�
alarm�within�30�seconds�after�you�enter�your�home�and�within�30�seconds�before�you�leave�it�so�that�
you�can�leave�and�enter�your�home�without�triggering�an�alarm.�Refer�to�the�instructions�on�page�6�
of�this�manual�to�learn�how�to�set�the�entry�and�exit�delay.�It is recommended to assign the Door /
Window Contact to the Delay zone.
Home zone
When the system is armed in Home Mode, the sensors assigned to the Home zone do not trigger an
alarm.�It is recommend to assign motion dectors to the Home zone so that you can have your system
armed in Home Mode when you are home and move inside your home without triggering any alarm.
SMS�Operations
IMPoRtANt: BEFoRE USING FoR tHE
FIRSt tIME
SAVE�A�PHONE�NUMBER�FOR�SMS�
NOTIFICATIONS.�(Refer�to�instructions�
on�the�opposite�column)
Only stored numbers can control and
configure the system.
INSERT A SIM CARD IN THE CONTROL PANEL
BEFORE�STARTING�SMS�OPERATIONS.
MAKE�SURE�THE�SIM�CARD�DOES�NOT�
REqUIRE�ANY�PIN�CODE.
Each�SMS�operation�defined�in�this�user�
manual�will�be�illustrated�as�follows:
You�send:
SMS Command
The first pink speech bubble is the SMS
command sent by the user.
The�control�panel�replies:
Control�panel’s�reply
The first grey speech bubble is the reply sent
by the control panel.
The speech bubbles that follow are the
dialogue between the user and the control
panel (SMS sent by the user are in pink, SMS
sent by the control panel are in grey).
The�system�is�in�English�by�default.�To�
change�the�system’s�language,�refer�to�page�
12�of�this�manual.
Store Phone numbers for SMS
notifications�
�
Send:
6
SMS�numbers:
1.
2.
3.
4.
5.
Copy, Paste, then Edit
�
�
(case�sensitive):
SMS�numbers:
1.�067890033
2.�067890022
3.�067890011
4.�067890000
5.
Ok
7
Disarm the System
Send:
0
System�disarmed.
Arm the System
Send:
1
System�armed.
Home Mode
�
Send:
2
System�in�home�mode.
Settings�Enquiry
�
Send:
00
System:Disarmed
AC�power:on
Entry�delay�time:0sec
Exit�delay�time:0sec
Siren�time:5min
Disarm�password:1234
Note
The�value�of�default�settings�will�be�changed�
after�having�set�up�the�system.
Store Phone Numbers
�
Send:
5
Phone�numbers:
1.
2.
3.
4.
5.
Copy, Paste, then Edit
�
�
(case�sensitive):
Phone�numbers:
1.�067890033
2.�067890022
3.�067890011
4.�067890000
5.
Ok
Change Zone Name
�
Send�“91~99”.�For�example�for�zone�1,�send:
91
Zones�names:
1.
Copy, Paste, then Edit
�
�
(case�sensitive):
Zones�names:
1.Entrance�door�alarm
Ok
Note
Zones� 1� to� 9� can� be� renamed.� The� name�
of the zone cannot consist of more than
30� Latin� characters� per� line� due� to� SMS�
character� limit.� Zones� 10� to� 99� cannot� be�
renamed.
been renamed, an SMS will be sent under
the�format�“Zone�name�+�low�battery”.�
Bedroom�PIR�low�battery
For�accessories�assigned�to�zones�that�have�
not been renamed, an SMS will be sent under
the�format�“Zone�number�+�low�battery”.
Zone�10�low�battery.
SMS Alert for Accessory tamper Alarm
(available�for�two-way�acessories�such�as�
Motion�Detectors)�
For�accessories�assigned�to�zones�that�have�
been renamed, an SMS will be sent under
the�format�“Zone�name�+�tamper alarm”.�
Bedroom�PIR�tamper�alarm.
For�accessories�assigned�to�zones�that�have�
not been renamed, an SMS will be sent
under� the� format� “Zone� number� +� tamper
alarm”.
Zone�10�tamper�alarm.
Entry and Exit Delay time
Send:
11
Entry�delay�time(0-300sec):0
Exit�delay�time(0-300sec):0
Copy, Paste, then Edit
�
�
(case�sensitive):
Entry�delay�time(0-300sec):10
Exit�delay�time(0-300sec):20
Ok
Note
This�function�can�be�used�if�you�do�not�want�
to bring a remote control or RFID tag with
you.� When� the� system� is� armed,� you� hear�
one� beep� every� second� to� remind� you� to�
leave.�The�beep�rhythm�speeds�up�during�the�
last� 10� seconds.� If� an� intruder� is� detected,�
the�alarm�will�be�delayed�accordingly.
Siren Volume and Ringing time
�
Send:
12
Siren�volume(0=Mute,1=High):1
Siren�ringing�time(1-9min):5
Copy, Paste, then Edit
�
�
(case�sensitive):
Siren�volume(0=Mute,1=High):0
Siren�ringing�time(1-9min):1
Ok
Note
If�the�Siren�ringing�time�is�set�to�0,�the�siren�
is�deactivated.
Disarm Password
Send:
13
Disarm�password�(4�digits):
1234
Copy, Paste, then Edit
�
�
(case�sensitive):
Disarm�password�(4�digits):
8888
Ok
Set Ringing times
Send:
19
Ringing�time:5
Copy, Paste, then Edit
�
�
(case�sensitive):
Ringing�time:3
This�function�enables�you�to�define�the�number�of�
times�the�control�panel�rings�before�taking�the�call.�
Ring�times�can�be�set�from�0�to�9.�When�set�to�0,�
the�alarm�system�will�not�ring�when�being�called.
the alarm detects an intrusion, the alarm will
keep�re-dialing�the�number�a�certain�amount�
of�times.
Send:
20
Call�repetition:5
Copy, Paste, then Edit
�
�
(case�sensitive):
Call�repetition:3
The� number� of� call� repetitions� can� be� set�
from�1�to�9.
Delete all Wireless Accessories
Send:
21
Ok
Change system language
Send�the�code�of�the�language.�For�example,�
for�English,�send�“0001”.��
0001
Ok
Refer to the table below for the full list of
languages:
0001 English
0002 French
0003 Russian
0004 Danish
0005 Dutch
0006 Italian
0007 Swedish
0008 German
0009 Spanish
0010 Finnish
0011 Norwegian
0012 Arabic
0013 Farsi
Languages�available�may�vary�depending�on�
the�version�of�your�product.
Restore�System�to�Factory�Settings�by�SMS�
Send:
0000
System�restored�to�factory�settings
The� settings� will� be� restored� to� default�
values.�
Stored�
phone�
numbers�
and�
connected�accessories�will�also�be�deleted.
Only stored numbers can send the SMS to
restore�factory�settings.
Accessories
Wireless Remote Control
Home Mode
Arm
SOS
Disarm
LED indicator
Arm the system
Press� the� Arm� button� " "� to� arm� the� alarm�
system.�The�LED�indicator�lights�up�(the�siren�
rings�out�once).�The�system�is�armed.
If an intruder is detected, the siren rings
out.� (The� siren� turns� off� after� 5� minutes� as�
per� default� settings.)� In� the� meantime,� the�
system dials the pre-stored phone numbers
automatically.
Disarm the system
Press� the� Disarm� button� " "� to� disarm� the�
alarm�system.�The�LED�indicator�turns�off�(the�
siren�rings�out�twice).�The�system�is�disarmed.
Home Mode
Press� the� Home� Mode� button� "
"� on� the�
remote�control.�The�system�state�LED�is�on.�
All the sensors in regular zones are armed
except� those� in� the� Home� Mode� zone.�
The sensors in the Home Mode zone are
disarmed�so�that�users�can�move�inside�their�
home.
Regardless the status of the system, the alarm
is� triggered� when� the� SOS� button� "SOS"� is�
pressed�on�the�remote�control.
At�the�same�time,�the�control�panel�sends�a�
notification� by� SMS� and� dials� the� pre-stored�
phone�numbers.
Register in the control panel
Press�the�connection�button�at�the�back�of�the�control�panel�to�enter�the�Connection�mode.�Press�
any�button�of�the�remote�control.
Specifications
Power�supply:
DC�3V�(CR2025�button�battery�x1)
Operation�current:
≤7�mA
Static�current:
10 uA
Transmission distance
≤�80�m�(in�open�area)
Radio-frequency:
433MHz�(±75KHz)
Housing�material:
ABS�plastic
Operating�conditions:
Temperature:�-10°C�~�+55°C
Relative�Humidity:�≤80%�
(non-condensing)
Dimensions:
57�x�31�x�11�mm
Wireless�Motion�Detector�
Features
The� MS-01A� (or� MS-02A:� Pet-Immune� Motion� Detector)� is� a� high� performance� wireless� �
motion�detector�boasting�a�digital�dual-core�fuzzy�logic�infrared�control�chip�with�intelligent�
analysis.�This�technology�identifies�interferences�created�by�body�motion�and�reduces�the�
false�alarm�rate.
With� automatic� temperature� compensation� and� anti-air� turbulence� technology,� it� easily�
adapts�to�environmental�changes.�
Design
3
1
2
1. LED indicator
2. Detection window
3. Bracket
PCB Layout
Alarm zone
setup
Tamper
switch*
Infrared
sensor**
AA 1.5V LR6
Antenna
LED working
indicator
*Tamper switch
When the alarm system is armed, the tamper
switch will trigger the alarm if the case is
opened.
**Infrared sensor
Detects the infrared rays released by human
body�motion.�Do�not�touch�the�surface.�Keep�
the�surface�clean.
LED�indications
Blinks�continuously:�self-testing�
Blinks once: an intruder is detected
Blinks twice:�self-testing�is�complete;�entering�working�mode.
Blinks once every 3 seconds:�under-voltage�indication:�the�batteries�must�be�replaced.�(You�will�
be�informed�by�SMS�when�the�batteries�are�low�if�the�motion�detector�is�registered�in�the�control�
panel.)
When the sensor is in operation, if it is
triggered more than twice within 3 minutes,
it will switch to standby mode to save power.
If no movement is detected within the next
3 minutes, the sensor goes back to working
mode.
Connect�Button
Register in the control panel
Press�the�Connection�button�at�the�back�of�the�control�panel�to�enter�the�Connection�mode.�
Press�the�connect�button�at�the�back�of�the�motion�sensor�or�trigger�the�sensor�(by�moving�in�
front�of�it).
Installation
Avoid� mounting� the� detector� close� to� windows,� air� conditioner,� heater,� refrigerator,� oven,�
sunshine� and� places� where� the� temperature� changes� fast� or� where� the� air� stream� flows�
frequently.
�
If�two�detectors�are�installed�in�the�same�detection�scope,�adjust�the�location�to�avoid�interferences�
and�false�alarms.
Fix� the� bracket� on� the� wall� with�
screws� and� attach� the� detector� to� the�
bracket.� Adjust� the� bracket� to� change�
the� detection� distance� and� angle.� It� is�
recommended to mount the detector
2m�from�the�ground.
Top
Bottom
Ground
2.2 m
The detector is more sensitive to
cross
movements
than
vertical
movements.
Side�view
Top�view
Testing
A.�After�the�installation,�turn�the�detector�on.�After�one�minute�of�self-testing,�press�the�test�
button,�walk�in�the�scope�of�detection�and�watch�the�LED�indicator�to�make�sure�the�detector�
is�working.
B.�The�LED�indicator�blinks�once�when�body�movement�is�detected.
C.�Adjust�the�detector�angle�to�achieve�the�best�detection�performance.
Specifications
Power supply
DC�3V�(AA�1.5V�LR6�Batteries�x�2)
Static�current
≤�30uA
Alarm current
≤�15�mA
Detection�scope
8m�/�110°
Trating�distance
≤�80m�(in�open�area)
Radio-frequency
315�MHz�/�433�MHz�(±75�KHz)
Housing material
ABS�plastic
Operating�conditions
Temparature:�-10°C~55°C
Relative�humidity:�≤�80%�(non-condensing)
Detector�dimensions�(L�x�W�x�H)
107�x�53�x�32�mm
Bracket�dimensions�(L�x�W�x�H)
52�x�30�x�26.5�mm
Detection�Scope
110°
Top�view
0m
2m
4m
6m
8m
2m
0m
Side�view
Wireless Door / Window Contact
Features
The ES-D3A is a Door / Window Contact that can be installed on doors, windows, and any other
objects�that�open�and�close.�The�sensor�sends�signals�to�the�control�panel�when�the�magnet�is�
separated�from�the�transmitter.
Thanks�to�the�tamper�switch,�any�attempt�to�remove�the�cover�of�the�Door�/�Window�Contact�
will�trigger�the�alarm.
Design
Magnet
Transmitter
LED indicator
PCB Layout
LED working indicator
Zone setting
A23 12V Battery
Tamper switch
LED�indications
Blinks once:�the�door�or�window�is�open�and�the�transmitter�sends�a�signal�to�the�control�panel.
Blinks�quickly:�Low�power�indication:�the�batteries�must�be�replaced.
Register the detector in the alarm system
Press�the�Connection�button�at�the�back�of�the�control�panel�to�enter�the�Connection�mode.�Then�
separate�the�magnet�from�the�transmitter.
To� check� if� the� registration� is� complete,� arm� the� system� and� separate� the� magnet� from� the�
transmitter�again�by�opening�the�door�or�window�on�which�it�is�installed.�If�the�siren�rings�out,�
the�registration�is�successful.�
Installation
- Open�the�case�and�remove�the�battery�activation�strip.
- Mount the sensor on the door and the magnet on the
door�frame.
- Make�sure�the�magnet�is�placed�above�the�transmitter.
- Mount�the�magnet�max.�1�cm�away�from�the�transmitter�
and�secure�the�transmitter�and�magnet�with�double-sided�
tape�or�screws.
- Avoid�mounting�the�sensor�in�areas�with�a�large�amount�of�
metal�or�electrical�wiring�such�as�a�furnace�or�utility�room.
Specifications
Power supply
DC�12V�(A23�12V�Battery�x�1)
Static�current
≤�30�uA
Alarm current
≤�15�mA
Transmitting�distance
≤80�m�(in�open�area)
Radio-frequency
315�MHz�/�433�MHz�(±75�KHz)
Housing material
ABS�plastic
Operating�temperature
-10°C~55°C
Relative�humidity
≤80%�(non-condensing)
Transmitter�dimensions�(LxWxH)
60 x 45 x 18 mm
Magnet�dimensions�(LxWxH)
45�x�19�x�17,5�mm
No response following
interaction�with�the�
control panel
The control panel is switched
off
Turn the power on
AC Power failure
Contact�your�electricity�provider
Backup�batteries�are�empty
Plug�the�AC�adapter�to�an�AC�socket
Accessories cannot
connect to the control
panel
The control panel is not in
Connection�mode
Make�sure�the�control�panel�is�in�
Connection�mode
Accessories�have�not�been�
triggered�for�connection
Make�sure�the�accessory�is�triggered�
so to send a signal to the control
panel
When�attempting�the�
connection,�the�control�panel�
beeps twice
The accessory has already been
connected
Make�sure�you�do�not�trigger�any�
other�accessory�when�connecting�
one accessory to the control panel
(e.g.�do�not�stay�in�the�detection�
scope�of�a�motion�detector�if�it�is�
not�the�one�you�want�to�connect)
No response from the
control panel following
commands from the
remote control
The remote control has not
been connected to the control
panel
Follow�the�instructions�in�this�
manual to connect the remote
control to the panel
Remote control is too far from
the control panel
Transmission distance of the remote
control:�80�m�(in�open�area)
A signal repeater can be installed to
increase the transmission distance
- Do� not� press� the� SOS� key� on� the� remote� control� if� it� is� unnecessary� to� avoid� disturbing�
neighborhood.
- Check�the�system�regularly�to�make�sure�the�system�works�properly.
- The control panel is neither waterproof nor moisture-proof, install it in a shady, cool and dry
place.
- The�case�of�the�control�panel�is�made�of�ABS�plastic.�Keep�away�from�bright�light�for�a�longer�
lifespan.
- The�control�panel�is�not�explosion-proof.�Keep�away�from�fire�and�flames.
- Install�the�control�panel�away�from�objects�such�as�heater,�air�conditioner,�microwave�oven�etc.�
that�generate�heat�or�electromagnetic�fields.
- Dispose�of�the�batteries�according�to�local�regulations.
- Dismantling�of�this�product�must�be�done�by�professional�personnel�only.
Standards
This�product�bears�the�selective�sorting�symbol�for�waste�electrical�and�electronic�equipment�(WEEE).�
This�means�that�this�product�must�be�handled�pursuant�to�European�Directive�2002/96/EC�in�order�
to�be�recycled�or�dismantled�to�minimize�its�impact�on�the�environment.
For�further�information,�please�contact�your�local�or�regional�authorities.
Electronic�products�not�included�in�the�selective�sorting�process�are�potentially�dangerous�for�the�
environment�and�human�health�due�to�the�presence�of�hazardous�substances.
In�compliance�with�European�laws.
This� product� was� designed� and� manufactured� in� compliance� with� Directive� 2002/95/EC� of� the�
European�Parliament�and�of�the�Council�on�the�restriction�of�use�of�certain�hazardous�substances�
in�electrical�and�electronic�equipment�(RoHS�Directive�-�RoHS)�and�is�deemed�to�comply�with�the�
maximum�concentration�values�set�by�the�European�Technical�Adaptation�Committee�(TAC).
Manufactured�in�China.
FCC Information and Copyright
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
—Consult the dealer or an experienced radio/TV technician for help.
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions:
(1)This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may
cause undesired operation.
changes or modifications not expressly approved by the party responsible for compliance could
void the user's authority to operate the equipment.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment .This equipment should be installed and operated with minimum distance 20cm
between the radiator& your body. This transmitter must not be co-located or operating in
conjunction with any other antenna or transmitter.
Rm�402-403,�4th�Floor�Skyworth�Semiconductor�Design�
Building�West�Wing,�Nanshan�District,�Shenzhen,�China.
www.maxsmart.cn
SG2-GSM-UM-EN-20141008-1.4