KIEN1005 Industrial Ethernet Switch

Hardware Installation Manual Kyland Technology Co., Ltd. Publication Date: Jan. 2013 Version: V4.0 Customer Service Hotline: (+8610) 88796676 FAX: (+8610) 88796678 Website: http://www.kyland.com E-mail: [email protected] No.: 1.12.02.1010-0

KIEN1005 Industrial Ethernet Switch

Hardware Installation Manual Disclaimer: Kyland Technology Co., Ltd. tries to keep the content of this manual as accurate and as updated as possible. This document is not guaranteed to be error-free, and we reserve the right to amend it without notice to users. All rights reserved. No part of this documentation may be excerpted, reproduced, translated, annotated or duplicated, in any form or by any means without the prior written permission of KYLAND Corporation. Copyright © 2013 Kyland Technology Co., Ltd.

Notice for Safety Operation

The product performs reliably as long as it is used according to the guidance. Artificial damage or destruction of the device should be avoided. Before using the device, read this notice carefully for personal and equipment safety. Please keep the manual for further reference. Kyland is not liable to any personal or equipment damage caused by violation of this notice.  Do not place the device near water sources or damp areas. Keep the ambient relative humidity within the range from 5% to 95% (non-condensing).  Do not place the device in an environment with high magnetic field, strong shock, or high temperature. Keep the working and storage temperatures within the allowed range.  Install and place the device securely and firmly.  Please keep the device clean; if necessary, wipe it with soft cotton cloth.  Do not place any irrelevant materials on the device or cables. Ensure adequate heat dissipation and tidy cable layout without knots.  Wear antistatic gloves or take other protective measures when operating the device.  Avoid any exposed metal wires because they may be oxidized or electrified.  Install the device in accordance with related national and local regulations.  Before power-on, make sure the power supply is within the allowed range of the device. Overhigh voltage may damage the device.  Power connectors and other connectors should be firmly interconnected.  Do not plug in or out the power supply with wet hands. When the device is powered on, do not touch the device or any parts with wet hands.  Before operating a device connected to a power cable, remove all jewelries (such as rings, bracelets, watches, and necklaces) or any other metal objects, because they may cause electric shock or burns.  Do not operate the device or connect or disconnect cables during lightning.  Use compatible connectors and cables. If you are not sure, contact our sales or technical support personnel for confirmation.  Do not disassemble the device by yourself. When an anomaly occurs, contact our sales or technical support personnel.  If any part is lost, contact our sales or technical support personnel to purchase the substitute. Do not purchase parts from other channels.

 Dispose of the device in accordance with relevant national provisions, preventing

environmental pollution. In the following cases, please immediately shut down your power supply and contact your Kyland representative:  Water gets into the equipment.  Equipment damage or shell damage.  Equipment operation or performance has abnormally changed.  The equipment emits odor, smoke or abnormal noise.

1 Product Overview

.................................................................................................................... 1 2 Structure and Interface ............................................................................................................ 2 2.1 Front Panel ........................................................................................................................... 2 2.2 Top Panel ............................................................................................................................. 4 3 Mounting .................................................................................................................................. 5 3.1 Dimension Drawing ............................................................................................................... 5 3.2 Mounting Modes and Steps .................................................................................................. 6 3.2.1 DIN-Rail Mounting ........................................................................................................... 7 3.2.2 Panel Mounting ............................................................................................................... 9 4 Connection ............................................................................................................................. 11 4.1 10/100Base-T(X) Ethernet Port .......................................................................................... 11 4.2 100Base-FX Ethernet Port .................................................................................................. 12 4.3 Grounding ........................................................................................................................... 13 4.4 Power Terminal Block ......................................................................................................... 13 5 LEDs ...................................................................................................................................... 15 6 Basic Features and Specifications ......................................................................................... 16

1 Product Overview

KIEN1005 includes a series of unmanaged 5-port industrial Ethernet switches developed by Kyland particularly for industrial applications. The series switches are applicable to harsh and hazardous industrial environments with reliable operation due to its high-performance switching engine, solid closed housing, low power consumption, fanless design, overcurrent, overvoltage, and EMC protection for power input, and sound EMC protection of RJ45 ports. The series switches support both DIN rail and panel mounting. They provide up to four 10/100Base-T(X) Ethernet ports and one 100Base-FX Ethernet port, as listed in the following table. Table 1 KIEN1005 Models Model Port Power Supply 100Base-FX Ethernet Port 10/100Base-T(X) Ethernet Port KIEN1005-1S/M-4T 1 4 12DCW, 220AC (single power supply) KIEN1005-5T -- 5 Note: For the product information listed in this table, we reserve the right to amend it without notice to users. To obtain the latest information, you can contact our sales or technical support personnel.

Structure and Interface

2 2 Structure and Interface Caution: To keep ports clean and ensure switch performance, you are advised to purchase the port dustproof shield (optional). 2.1 Front Panel  Front Panel of KIEN1005-1S/M-4T Figure 1 Front Panel of KIEN1005-1S/M-4T Table 2 Description of the Front Panel of KIEN1005-1S/M-4T No. Identifier Description (1) POW Power LED (2) ACT 100Base-FX Ethernet port connection status LED (3) TX/RX 100Base-FX Ethernet port (4) 1-4 10/100Base-T(X) Ethernet port (5) 10/100M 10/100Base-T(X) Ethernet port speed LED (yellow) (6) LINK/ACT 10/100Base-T(X) Ethernet port connection status LED (green)

Structure and Interface

3  Front Panel of KIEN1005-5T Figure 2 Front Panel of KIEN1005-5T Table 3 Description of the Front Panel of KIEN1005-5T No. Identifier Description (1) POW Power LED (2) 1-5 10/100Base-T(X) Ethernet port (3) 10/100M 10/100Base-T(X) Ethernet port speed LED (yellow) (4) LINK/ACT 10/100Base-T(X) Ethernet port connection status LED (green)

Structure and Interface

4 2.2 Top Panel Figure 3 Top Panel of KIEN1005 Table 4 Description of the Top Panel of KIEN1005 No. Identifier Description (1) Grounding screw (2) Power terminal block

3.1 Dimension Drawing

Figure 4 Dimensions for DIN-Rail Mounting 1 (unit: mm) Figure 5 Dimensions for DIN-Rail Mounting 2 (unit: mm)

Figure 6 Dimensions for Panel Mounting (unit: mm)

Caution:  The manual provides two dimensions for DIN-rail mounting. You can follow the dimension and related mounting steps according to the type of DIN rail in use.  The figures in this manual are only for reference.  As part of the heat dissipation system, the switch housing becomes hot during operation. Please use caution when coming in contact and avoid covering the switch housing when the switch is running. 3.2 Mounting Modes and Steps The series switches support DIN rail and panel mounting. Before installation, make sure that the following requirements are met. 1) Environment: temperature (-40℃ to 85℃), ambient relative humidity (5% to 95%, non-condensing) 2) Power requirement: The power input is within the voltage range of the switch. 3) Grounding resistance: <5Ω 4) No direct sunlight, distant from heat source and areas with strong electromagnetic interference.

3.2.1 DIN-Rail Mounting

 DIN-Rail Mounting 1 Step 1: Select the mounting position for the device and guarantee adequate space and heat dissipation for it (dimensions: 36.5mm×120mm×90mm). Step 2: Insert the lower edge of the DIN rail into the bend of the lower hooks of the DIN rail connecting seat. Pull the device upward and move the device in direction 2 to insert the upper edge of the DIN rail into the bend of the upper hooks of the connecting seat. In this way, the device is mounted on the DIN rail, as shown in the following figure. Figure 7 DIN-Rail Mounting 1

 DIN Rail Dismounting 1

Step 1: As shown in the following figure, pull the device upward and move it in direction 2 until the upper edge of the DIN rail is detached from the upper hooks of the connecting seat. Step 2: Push the device downward until the DIN rail is removed from the connecting seat completely. Figure 8 DIN-Rail Dismounting 1  DIN-Rail Mounting 2 Step 1: Select the mounting position for the device and guarantee adequate space and heat dissipation for it (dimensions: 36.5mm×120mm×90mm). Step 2: Insert the connecting seat onto the top of the DIN rail, and push the bottom of the device inward and upward to ensure the DIN rail fits in the connecting seat. Make sure the device is firmly installed on the DIN rail, as shown in the following figure. Figure 9 DIN-Rail Mounting 2

 DIN Rail Dismounting 2

Step 1: As shown in the following figure, press the device downward and move the device in direction 1 until the bottom of the device is detached from the DIN rail. Step 2: Pull the device upward and move the device in direction 2 until the device is removed from the DIN rail completely. Figure 10 DIN Rail Dismounting 2 3.2.2 Panel Mounting Caution: To adopt panel mounting, you need to purchase the plate (optional) for panel mounting.  Panel Mounting Step 1: Use screws to secure the plate for panel mounting to the rear panel of the device. Step 2: Select the mounting position (on a wall or inner wall of a cabinet) for the device and guarantee adequate space and heat dissipation for it (dimensions: 36.5mm×120mm×90mm). Step 3: Punch four holes in the selected position according to the dimensions for panel mounting. Insert four screws into the four holes respectively, and turn the screws with a screwdriver until about a 5mm distance is left between each screw head and the wall. Step 4: Align the four mounting holes on the plate for panel mounting with the four screws. Make the screws pass through the Ф6.5 positions in the following figure. Move the device in direction 1 until the four screws are in the Ф4 positions. Then tighten the screws.

Figure 11 Panel Mounting

 Panel Dismounting Step 1: Loosen the four screws with a screwdriver. Pull the device upward until the four screws are in the Ф6.5 positions in the following figure. Then remove the plate for panel mounting from the four screws to detach the device from the wall or inner wall of the cabinet. Step 2: Loosen the screws completely with a screwdriver. Remove them from the wall or inner wall of the cabinet. Then remove the plate for panel mounting from the rear panel to complete dismounting the device. Figure 12 Panel Dismounting

4.1 10/100Base-T(X) Ethernet Port

10/100Base-T(X) Ethernet port is equipped with RJ45 connector. The port is self-adaptive. It can automatically configure itself to work in 10M or 100M state, full or half duplex mode. The port can also adapt to MDI or MDI-X connection automatically. You can connect the port to a terminal or network device with a straight-through or cross-over cable.  Pin Definitions The following figure shows the pin numbers of the RJ45 port. 8 7 6 5 4 3 2 1 Figure 13 RJ45 Port The following table lists the pin definitions of the 10/100Base-T(X) RJ45 port. Table 5 Pin Definitions of 10/100Base-T(X) RJ45 Port Pin MDI-X Signal MDI Signal 1 Receive Data+ (RD+) Transmit Data+ (TD+) 2 Receive Data- (RD-) Transmit Data- (TD-) 3 Transmit Data+ (TD+) Receive Data+ (RD+) 6 Transmit Data- (TD-) Receive Data- (RD-) 4, 5, 7, 8 Unused Unused Note: "+" and "-" indicate level polarities.

 Wiring Sequence

Figure 14 Connection Using Straight-through/Cross-over Cable Note: The color of the cable for RJ45 connector meets the 568B standard: 1-orange and white, 2-orange, 3-green and white, 4-blue, 5-blue and white, 6-green, 7-brown and white, and 8-brown. 4.2 100Base-FX Ethernet Port 100Base-FX Ethernet port is equipped with FC/ST/SC connector, and each port consists of TX (transmit) port and RX (receive) port. To enable data transmission between Device A and Device B, connect the TX (transmit) port of Device A to the RX (receive) port of Device B, and the RX (receive) port of Device A to the TX (transmit) port of Device B. The following figure shows the wiring sequence of the 100Base-FX Ethernet port. (The following uses an SC port as an example. The wiring sequence of an ST/FC port is the same with that of the SC port.) Figure 15 Connection of 100Base-FX Ethernet Port Caution: The device uses laser to transmit signals in fibers. The laser meets the requirements of level 1 laser products. Routine operation is not harmful to your eyes, but do not look directly at the fiber port when the device is powered on.

Grounding protects the device from lightning and interference. Therefore, you must ground the

device properly. You need to ground the device before it is powered on and disconnect the grounding cable after the device is powered off. There is a grounding screw on the top panel of the switch. The screw is for chassis grounding. After crimping one end of the grounding cable to a cold pressed terminal, secure the end to the grounding screw and connect the other end to the earth firmly. Figure 16 Grounding Note: Cross-sectional area of the chassis grounding cable>2.5mm2; grounding resistance<5Ω. 4.4 Power Terminal Block There is a power terminal block on the top panel of the device. You need to connect the power wires to the terminal block to provide power for the device. The device supports single power supply with 3-pin 3.81mm-spacing plug-in terminal block. Note: 0.75mm2

The following figure lists the pin definitions of the 3-pin 3.81mm-spacing plug-in terminal block.

Table 6 Pin Definitions of 3-Pin 3.81mm-Spacing Plug-in Terminal Block No. DC Definition AC Definition 1 - N 2 + L 3 PGND PGND  Wiring and Mounting Step 1: Ground the device properly according to section 4.3. Step 2: Remove the power terminal block from the device. Step 3: Insert the power wires into the power terminal block according to Table 6 and secure the wires. Step 4: Insert the terminal block with the connected wires into the terminal block socket on the device. Step 5: Connect the other end of the power wires to the external power supply system according to the power supply requirements of the device. View the status of the power LED. If the LED is on, the power is connected properly. Figure 18 Connection of 3-Pin 3.81mm-Spacing Plug-in Terminal Block Caution: The switch supports 12DCW and 220AC power input. Before connecting the device to power supply, make sure that the power input meets the power requirement. If connected to an incorrect power input, the device may be damaged. Warning:  Do not touch any exposed conducting wire, terminal, or component with a voltage warning sign, because it may cause damage to humans.  Do not remove any part or plug in or out any connector when the device is powered on.

Table 7 Front Panel LEDs

LED State Description Power LED On The device is connected to power supply and operates properly. Off The device is not connected to power supply or operates abnormally. 100Base-FX Ethernet port connection status LED On Effective port connection Blinking Ongoing network activities Off No effective port connection 10/100Base-T(X) Ethernet port speed LED (yellow) On 100M working state (100Base-TX) Off 10M working state (10Base-T) or no connection 10/100Base-T(X) Ethernet port connection status LED (green) On Effective port connection Blinking Ongoing network activities Off No effective port connection

Basic Features and Specifications

16 6 Basic Features and Specifications Power Requirements Power Identifier Rated Voltage Range Maximum Voltage Range 12DCW 12-24VDC 9-36VDC 220AC 100-240VAC, 50/60Hz 85-264VAC Terminal block 3-pin 3.81mm-spacing plug-in terminal block Rated Power Consumption Rated power consumption 3.6W (MAX) Physical Characteristics Housing Metal, fanless Installation DIN rail or panel mounting Dimensions (W×H×D) 36.5mm×120mm×90mm (excluding the connector, DIN rail, and component for panel mounting) Weight 0.3Kg Environmental Limits Operating temperature -40℃ to +85℃ Storage temperature -40℃ to +85℃ Ambient relative humidity 5% to 95% (non-condensing) MTBF MTBF 454,730 hours Warranty Warranty 5 years For more information about KYLAND products, please visit our website: http://www.kyland.cn/