This package contains:

One ST-WD600PTZMINI vandalproof intelligent dome color camera One installation manual Note: The ST-WD600PTZMINI requires a minimum 12VDC 500mA power supply such as the ST-PS12VDC1A or ST-PS12VDC2A. PRODUCT DESCRIPTION The ST-WD600PTZMINI is a professional grade IP66-rated outdoor dome color camera with pan, tilt and zoom (PTZ) capability of 600TVL of resolution. The camera’s full digital design allows the saving of all settings in non-volatile memory. The camera features include a 5mm – 15mm varifocal lens. SPECIFICATIONS ST-WD600PTZMINI Specifications (Typical) 1. Image Sensor 1/3” SONY Super HAD CCD II 2. Resolution 600TVL 3. Lens 5mm – 15mm auto focus lens 4. Effective Picture Elements 811x508 5. Minimum Illumination 0.001 Lux 6. Scanning System 2:1 interface 7. Video Output 1.0VP-P, 75Ω 8. Signal to Noise Ratio >48dB 9. Synchronous System Internal, Negative synch 10. Auto Electronic Shutter 1/60s ~ 1/100,000s 11. Gama Correction 0.45 12. Auto Gain Control Auto 13. Power DC12V 500mA 14. Operating Relative Humidity 95% maximum 15. Operating Temperature 14°F – 113°F 16. Dimensions 4.8”x7” 17. Weight 3.3 lbs

INSTALLATION AND OPERATION

CAUTION: To reduce the risk of electrical shock do not remove the cover or back of this unit. No user serviceable parts are inside. CAUTION: To prevent electric shocks and risk of fire hazards, do not use other than specified power source. 1. UNPACKING and HANDLING Each unit is shipped assembled and factory tested. Ensure that all accessories are removed from the container before discarding packing material 2. MECHANICAL INSPECTION Inspect the front and rear of the equipment for shipping damage. Make sure the equipment is clean, and no connectors are broken, damaged, or loose. If equipment appears to be damaged or defective please contact your distributor or Securitytronix at 1-610-429-1511 for assistance. 3. SPECIAL ATTENTION a. The installer must comply with electrical safety standards. There must be sufficient space between the camera’s power supply and video line and any high voltage equipment and/or cables. b. To help ensure the camera’s life and proper operation do not point the camera towards the sun or strong light. c. Do not install the camera in an environment where the temperature is above 113° F. d. Do not install the camera near a magnetic field or a high-power motor. e. Do not mount the camera near a radiator or heater. f. Only use a dry cloth to clean the camera. If there is dirt that is difficult to remove wipe gently with a mild detergent. Never use strong or abrasive detergents. g. A minimum 12VDC 500mA power supply must be used. AC power cannot be applied. Using an AC or other incorrect power supply will damage the camera. h. Only qualified installers are allowed to install, test and disassemble the camera. i. The camera is a low voltage product. If installed outdoors proper safety and lightening grounding are required. This symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions. This symbol is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electrical shock.

4. WIRING CONNECTIONS

a. Connect the power supply’s DC plug to the camera’s power outlet. b. Connect the camera to the monitor with a 75Ω coaxial video cable. c. Connect unshielded twisted pair (UTP) control cable between the camera’s RS485 port and the PTZ controller. Be sure wire polarities are the same at each connection. The camera’s violet wire (A) is + positive and the white wire (B) is – negative. d. Connect power supply’s AC plug to a suitable AC power outlet. e. Adjust the lens direction according to the required surveillance area and environment.

5. SETTING CAMERA ADDRESS, PROTOCOL and BAUD RATE USING DIP-SWITCHES

Camera address, protocol and baud rate can be set using the camera’s OSD menus and a PTZ controller connected to the camera or using the camera’s onboard DIP-switches. To use the camera’s DIP-switches, open the camera’s top cover. The switches are mounted on the camera’s printed circuit board. There are 10 DIP-switches:  Switches 1 through 6 are used to set the camera address.  Switches 7 and 8 are used to set the camera baud rate.  Switch 9 is used to set the camera protocol.  Switch 0 is used to set RS485 terminal resistance. DIP-switch settings are 1 = ON, 0 = OFF. a. Setting Camera Address: DIP-Switches 1, 2, 3, 4, 5, 6 Camera No. DIP-Switch Setting Camera No. DIP-Switch Setting 1 1 0 0 0 0 0 17 1 0 0 0 1 0 2 0 1 0 0 0 0 18 0 1 0 0 1 0 3 1 1 0 0 0 0 19 1 1 0 0 1 0 4 0 0 1 0 0 0 20 0 0 1 0 1 0 5 1 0 1 0 0 0 21 1 0 1 0 1 0 6 0 1 1 0 0 0 22 0 1 1 0 1 0 7 1 1 1 0 0 0 23 1 1 1 0 1 0 8 0 0 0 1 0 0 24 0 0 0 1 1 0 9 1 0 0 1 0 0 25 1 0 0 1 1 0 10 0 1 0 1 0 0 26 0 1 0 1 1 0 11 1 1 0 1 0 0 27 1 1 0 1 1 0 12 0 0 1 1 0 0 28 0 0 1 1 1 0 13 1 0 1 1 0 0 29 1 0 1 1 1 0 14 0 1 1 1 0 0 30 0 1 1 1 1 0 15 1 1 1 1 0 0 31 1 1 1 1 1 0 16 0 0 0 0 1 0 32 0 0 0 0 0 1 b. Setting Camera Baud Rate: DIP-Switches 7, 8 Baud Rate Switch 7 8 1200bps 1 0 2400bps 0 0 4800bps 1 1 9600bps 0 1 c. Setting Camera Protocol: DIP-Switch 9 Protocol Switch 9 PELCO-P 1 PELCO-D 0 d. Setting RS485 Terminal Resistance: DIP-Switch 0 RS485 Resistance Switch 0 Connect to 120Ω Resistor 1 No Connection to 120Ω Resistor 0

The camera uses preset commands to achieve a number of functions. CLEAR / SET / GOTO

and the preset number to perform these functions. Set Preset Point Numbers: Preset No. Function 1 – 32 Set Preset Point 62 Set Left Limited Point 63 Set Right Limited Point 76 Set Home Point 77 Set Home Point Wait Time to 64 78 Set Home Point Wait Time to 128 79 Set Home Point Wait Time 192 80 Set Home Point Wait time to 255 81 Enable auto return to Home Point 82 Disable auto return to Home Point 92 Set Left Limited Point 93 Set Right Limited Point 94 Reset Original Point 240 Clean Setup 241 Initialize System 242 Start PATTERN Setup 243 End PATTERN Setup 247 Start PATTERN 248 Stop PATTERN Clear Preset Point Numbers: Preset No. Function 1 – 32 Clear Preset Point 62 Clear Left Limited Point 63 Clear Right Limited Point 76 Clear Home Point 92 Clear Left Limited Point 93 Clear Right Limited Point GoTo Preset Point Number: Preset No. Function 1 – 32 GoTo Preset Point 34 GoTo Pan Zero Point 76 GoTo Home Point 92 GoTo Left Limited Point 93 GoTo Right Limited Point 99 Start Auto Scan

To Set and Run a Pattern:

a. Input SET preset 242 to begin pattern learning. b. Send GOTO preset command so the camera will recognize this point as a pattern point. For example, if the camera is to tour at point 1, 3, and 6 input GOTO preset point 1, GOTO preset point 3 and GOTO preset point 1. c. Input SET preset 243 to end pattern learning. d. Input SET preset 247 to start pattern tour. e. Input SET preset 248 to stop pattern tour. 8. TROUBLESHOOTING a. No picture after applying power – (i) check all plugs and cables are securely connected to the proper connectors; (ii) ensure your power supply is providing the correct voltage and current. b. The picture has ripples – (i) check to see if the power supply is experiencing AC ripple, if so a filter may be required; (ii) determine if the monitor is faulty; (iii) determine if other peripheral equipment is causing ripple and if so make the necessary adjustments. c. The picture background continuously changes color – a fluorescent lamp’s magnetic field may cause color roll, therefore, reduce the number of fluorescent lamps or increase the distance between the camera and the lamps. d. The picture appears smeared – (i) the power supply voltage level may be unstable, therefore, try another power supply; (ii) ensure the cables are correctly connected and/or the cables are of the correct impedance. e. Other interference may require a Securitytronix ground loop isolation filter. f. Power is on, but the controller does not work – (i) check to make sure the DIP switches for address and communications baud rate are properly set, (ii) check to ensure the RS485 connections at the camera and the PTZ Controller have the same polarity, (iii) check the integrity and continuity of the unshielded twisted pair (UTP) control cable. g. Additional troubleshooting assistance can be found on-line at www.securitytronix.com in addition to support from Securitytronix sales engineers at 1-610-429-1511.